FG 15225A Three-Pole. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
JG 175250A Three-Pole. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
KG 300400A Three-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LG 450600A Three-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
MG 700800A Three-Pole. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
NG 9001200A Three-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
0.74
(18.8)
Note:
This Drawing Shall Not be Used for Circuit Breaker
Tolerances Except Where Specifically Identified.
1.56
(39.6)
0.38
(9.7)
1.38
(35.1)
0.19 (4.8) R
1.38
(35.1)
Line End
0.19 (4.8) R
0.75
(19.0)
0.82 1.03
(20.8) (26.2)
1.41
(35.8)
0.16
(4.1) R
0.38
(9.7)
2.72
(69.1)
0.38
(9.7)
4.50
(114.3)
1.33
(33.8)
1.33
(33.8)
0.34
(8.6)
1.13
(28.7)
2.99
(75.9)
3.38
53
(85.9)
0.22 (5.6)
Handle:
0.34 (8.6) Wide x
0.38 (9.7) Thick
0 Taper, Load End
7 Taper, Line End
4.00
(101.6)
E
R 0.09
(2.3)
1.22
(31.0)
0.19 (4.8)
2.38
4x 0.09
(2.3)R
0.17
(4.3)
0.02
(0.5)
Load End
2x 1.03
(26.2)
0.69
(17.5)
1.38
(35.1)
2.06
(52.3)
0.50
(12.7)
0.50
(12.7)
0.18
6.00
(4.6)
2.38
(60.5) (152.4)
0.27
+0.03 (0.8)
(6.9)
0.02 (0.5)
0.47
(11.9)
0.31
(7.9)
0.02 (0.5)
0.06
(1.5)
0.47
(11.9)
0.63
(16.0)
2.35 (59.7) R
1.72
(43.7)
0.27
(6.9)
0.62
(15.7)
0.75
(19.0)
0.08
(2.0)
Though for
Attachment Leads
0.75
(19.0)
0.08
(2.0)
0.75
(19.0)
1.77 (45.0)
2.22 (56.4)
To Top of Clip
0.47
(11.9)
0.25
(6.4)
2.94 (74.7)
3.19 (81.0)
+0.03 (0.8) 0.02 (0.5)
1.00
(25.4)
3.39 (86.1)
+0.03 (0.8) 0.02 (0.5)
3.50 (88.9)
+0.03 (0.8) 0.02 (0.5)
C
Breaker
Status
On
Tripped
Off
Reset
1.56
(39.6)
0.74
(18.8)
Dimensions
A
3.07 (78.0)
2.65 (67.3)
2.08 (52.8)
1.98 (50.3)
2.92 (74.2)
2.57 (65.3)
2.14 (54.4)
2.05 (52.1)
3.96 (100.6)
4.06 (103.1)
4.12 (104.6)
4.11 (104.4)
3.40 (86.4)
2.99 (75.9)
2.42 (61.5)
2.30 (58.4)
3.33 (84.6)
2.98 (75.7)
2.56 (65.0)
2.48 (63.2)
1.38
(35.1)
0.1632 Tap
6x
0.75
(19.1)
0.69
(17.5)
Line
End
2.88
(73.2)
4.50
(114.3)
Breaker
Handle
0.47
(11.9)
Line End
Load End
Front Connected Drilling Plan
3.16
(80.3)
Breaker
Handle
R 0.25
(6.4)
+0.03
6.000.02
2.31
(58.7)
Load End
2.91
(73.9)
1.38
(35.1)
2.75
(69.9)
0.44 (11.2) for 15 to 100A
0.56 (14.2) for 125 to 150A
Breaker
Handle
1.91
(48.5)
5.06
(128.5)
0.59
(15.0)
1.19
(30.5)
Load End
1.38
(35.1)
1.38
(35.1)
0.19
(4.8)
0.58
(14.7)
0.50
(12.7)
Location of Terminal
Access Holes if Required
Figure 2. Type FG 15225A Three-Pole Cutout and Drilling PlanDimensions in Inches (mm)
eaton corporation www.eaton.com
4.13 (104.9)
0.69
2.75 (69.9)
(17.5)
1.38
0.69
(35.1) (17.5)
Line End
0.03 (0.8)
0.19 (4.8) R
0.50 (12.7)
0.78 (19.8)
1.72
2.59
(65.8) (43.7)
0.13
(3.3)
CL Breaker
4.06 (103.1)
2.84
(72.1)
3.81 (96.8)
0.81 (20.6)
0.63 (16.0)
1.03
(26.2) 1.49
(37.8)
0.16 (4.1)
0.11 (2.8)
Diameter
6 Holes
0.50 (12.7)
7.25
(184.1)
8.34
(211.8)
10.00
(254.0)
ON
7.53
(191.3)
4.00
3.75 (101.6)
(95.3)
CL
Breaker
Handle
15
5.50
3
0.25
(6.4)
0.25
(6.4) R
TRIP
5.80
(147.3)
Center
1.51
(38.4)
Outside
0.90
(22.9)
0.04
OFF
1.06
(26.9)
RESET
0.88
(22.4)
0.47 (11.9)
Typical Three-Pole
Thermal-Magnetic
Trip Unit
0.50 (12.7)
For Generator
Breakers Only
0.06 (1.5)
0.63 (16.0)
0.75 (19.0)
Load End
0.19
(4.8)
0.03 (0.8)
1.38
(35.1)
3.83 (97.3)
4.06 (103.1)
0.88
(22.4)
4.31 (109.5)
4.94 (125.5) Max.
Terminal Arrangements
2.13
(54.1)
0.34
(8.6) R
3.94
(100.1)
0.94
(23.9)
1.56
(39.6)
0.19
(4.8) R
1.38 (35.1)
2.75 (69.9)
Ampere
Rating
Wire
Size
Torque
(Lb-in)
Style
Number
Catalog
Number
Cu single
Cu-Al single
70250
70250
#4350 kcmil
#4350 kcmil
180
275
1254C14G02
176C446G01
T250KB
TA250KB
1.00
(25.4)
0.56
(14.2) R
1.38
(35.1)
2.92
(74.2)
1.75
(44.4)
3.50
(88.9)
3.33
(84.6)
0.50 (12.7)
Diameter
3 Megger Holes
If Required
7.25
(184.1)
0.2520 Tap
8.09
4 Holes
(205.5)
0.25 0.50
(6.4) (12.7)
CL Handle
0.81
(20.6)
Breaker Mounting
0.44 (11.2)
Diameter
4 Holes
CL Handle
0.56 (14.2) R
1.38
(35.1)
0.38 0.75
8.09
(9.7) (19.0) (205.5)
4.89
(124.2)
4.08
(103.6)
2.75
(69.9)
1.38
(35.1)
0.69 (17.5)
CL Handle
0.88 (22.4)
2.75
(69.9)
0.81
(20.6)
0.78 (19.8)
CL Breaker
0.72
(18.3)
Cable
Type
0.69 (17.5)
1.38
(35.1)
0.63 (16.0)
Diameter
6 Holes
4.89
(124.2)
CL Handle
2.55
(64.8)
0.63 (16.0)
Diameter
(For Generator
Breakers Only)
Omit 2
Center Holes
For Two-pole
Breakers
Line End
Breaker Mounting Holes
Use M6 x 1 x 73.025 Pan
Head Screw with Sems
Tightening Torque 7.34 Nm
Load End M6 x 3.50 (88.9)
Pan Head
2.37
(60.3)
Line
0.28
(7.1)
Dia
1.00
(25.4)
0.50
(12.7)
0.50
(12.7)
0.31
(7.9)
Dia
0.50
(12.7)
Dia
5.64
(143.3)
4.89
(124.3)
9.72
(246.9)
CL of Breaker Handle
0.03
(0.8)
1.00
(25.4)
1.00
(25.4)
0.81
(20.7)
0.50
(12.7)
0.50
(12.7)
0.27
(6.8)
Dia
E
F
0.69
(17.5)
4.34
(110.2)
2.09
(53.1)
2.13
(54.1)
7.47
(189.7)
Load
1.81
(46.0)
1.13
(28.6)
2.75
(69.8)
1.37
(34.9)
3.63
(92.1)
2.25
(57.2)
3.09
(78.6)
CL Bkr
4.81
(122.3)
8 x 0.15
(3.8) Dia
0.50 (12.7)
Deep
0.37
(9.5)
On
Dimensions
0.37
(9.5)
0.75
(19.1)
Breaker
Status
Reset
Off
Off
75
75
75
Thermal
Magnetic
Trip Unit
5
10
Magnetic Multiples of In
Push to Trip
10
5
Amps (In) C
10
Cat. No.
Trip
On
3.91
(99.3)
4.02
(102.1)
4.79
(121.7)
5.20
(132.1)
3.96
(100.6)
4.06
(103.1)
4.71
(119.6)
5.12
(130.1)
4.21
(106.9)
4.32
(109.8)
5.10
(129.5)
5.54
(140.7)
4.36
(110.7)
4.45
(113.0)
5.10
(129.5)
5.49
(139.5)
4.90
(124.5)
4.91
(124.7)
4.87
(123.7)
4.79
(121.6)
4.95
(125.7)
4.95
(125.7)
4.85
(123.2)
4.72
(119.9)
Handle
Operating
Force (N)
169.0
97.9
142.3
Line End
5.49 (139.4)
3.43 (87.3)
Line End
1.71
(43.6)
n 0.62 (15.9)
0.50 (12.7)
0.83 (21.0)
0.18 (4.7) R
2.56
(65.1)
4.12 (104.8)
0.09 R
0.86 (21.8)
2.06 (52.4)
0.18 R (4.7)
0.37
(9.5)
0.12
(3.2)
2.43 (61.9)
3.56
(90.5)
Contact Position
Indicators
Red/I-On
Green/O-Off
White-Trip
0.75
(19.0)
4.00
(101.6)
4.92
(125.0)
10.12
(257.2)
8.43
(214.3)
q Breaker
Handle
0.25 (6.3)
1.62 (41.2)
3.51
(89.3)
2.39 (60.7)
4.78 (121.4)
0.19 (4.8) R
Load End
Line End
0.50 (12.7)
1.16
(29.5)
0.25 (6.3) R
0.94 (23.8)
0.87 (22.2)
1.06
(27.0)
3.81
(96.8)
Load End
0.06 (1.6)
0.44 (11.1)
Dimensions
for Extended
Terminals and
Barrier
Style Numbers
4212B60G02,
4212B61G02,
and 1492D24H01
Line End
0.86 (21.8)
0.84 (21.4)
Off / O
1.62 (41.3)
0.06
(1.6)
1.31 (33.3)
2.62
(66.7) 2.39
(60.7)
4.78 (121.5)
1.72 (43.7)
8.87
(225.4)
1.22 (30.9)
0.25 (6.3) R
8.44
(214.3)
On / I
0.37 (9.5)
1.64 (41.7)
1.25 (31.7)
2.81
(71.4)
1.72 (43.6)
4.43
(112.7)
1.25
(31.7)
3.75
(95.2)
q Breaker
Handle
7.40
(188.1)
q Breaker
Handle
0.34 (8.7) R
0.19
(4.8)
5.14
(130.6)
8.87
(225.4)
4.31 (109.5)
q Breaker
Handle
3.73
(94.8)
0.50
(12.7)
0.25-20 (M6)
Tap 4 Holes
1.87
(47.6)
0.69 (17.6)
1.00 (25.4)
2.37
(60.3)
43 ~
3.81 (96.8)
0.77 (19.5)
5.00
(127.0)
0.06 (1.6)
0.12 (3.2) Wide x 0.75 (19.0)
Slots for Attachment Leads
5.97
(151.5)
Trough for
Attachment Leads
1.06
(27.1)
q Handle
3.87 R
5.77
(146.4)
0.50 (12.7)
0.50 (12.7)
0.19 (4.8)
D
1.05
(26.6)
1.73
(44.0)
39 ~
0.21
(5.3)
For Generator
Breakers Only
0.50
(12.7)
0.06 (1.6)
4.06 (103.2)
E
F
Terminal Arrangements
Breaker
Status
On
Off
Tripped
Reset
Dimensions
A
5.39
4.16
4.77
4.07
5.20
4.21
4.69
4.14
5.69
4.46
5.08
4.57
5.61
4.64
5.11
4.56
4.72
4.95
4.89
4.95
4.77
4.91
4.89
4.90
Cable
Type
Wire
Size (kcmil)
Number
of Cables
Torque
(Lb-in)
Style
Number
Catalog
Number
Cu
Cu
Cu
Cu/Al
Cu/Al
Cu/Al
#3350
250500
3/0250
#3350
250500
3/0250
Single
Single
Double
Single
Single
Double
275
375
275
275
375
275
5112A68G02
5112A69G02
4212B60G02
5112A70G02
5112A71G02
4212B61G02
T300K
T350K
T400K
TA300K
TA350K
TA400K
0.87 (22.2) R
Line End
1.37
(34.9)
1.37 (34.9)
5.95
(151.2)
5.14
(130.6)
1.72
(43.7)
10.50
(266.7)
5.14
(130.6)
3.44 (87.3)
8.87
(225.4)
0.56
(14.3)
0.69
(17.5)
1.75
(44.4)
1.75
(44.4)
0.62 (15.9)
0.62 (15.9)
3.37 (85.7)
5.25 (133.3)
0.44 (11.1)
Dia.
4 Holes for
0.31 (7.9)
Mtg Bolts
3.73
(94.8)
1.71 (43.7)
3.73
(94.8)
0.86
(21.8)
0.31 (7.9)
1.37
(34.9)
1.37
(34.9)
0.62
(15.9)
0.56
(14.3)
3.37 (85.7)
8.87
(225.4)
Load End
Drilling Plan for Mounting
Panel Drawout Studs
9.69 (246.1)
0.34 R
(8.7)
3.44
(87.3)
q Breaker Handle
Line End
1.72
(43.7)
3.75
(95.2)
q Breaker
Handle
0.18 R
(4.8)
0.83 (21.0)
1.64 (41.7)
1.25 (31.7)
1.31 (33.3)
2.62 (66.7)
Load End
Front Cover
Cutout
2.39 (60.7)
4.78 (121.5)
1.72 (43.7)
Line End
0.86 (21.8)
0.84 (21.4)
4.92
(125.0)
8.44
(214.3)
q Breaker
Handle
3.52
(89.3)
0.25-20 (M6)
Tap 4 Holes
5.14
(130.6)
8.87
(225.4)
q Breaker
Handle
3.73
(94.8)
0.72 0.72
Drill Plan for Rear
(43.7) (43.7)
Connected Studs
4.47 (113.5)
OPTIM Circuit Breakers Only
Otherwise Same As Sheet 1
Load End
Terminal Arrangements
Breaker
Status
On
Off
Tripped
Reset
Dimensions
A
5.39
4.16
4.77
4.07
5.20
4.21
4.69
4.14
5.69
4.46
5.08
4.57
5.61
4.64
5.11
4.56
4.72
4.95
4.89
4.95
4.77
4.91
4.89
4.90
Cable
Type
Wire
Size (kcmil)
Number
of Cables
Torque
(Lb-in)
Style
Number
Catalog
Number
Cu
Cu
Cu
Cu/Al
Cu/Al
Cu/Al
#3350
250500
3/0250
#3350
250500
3/0250
Single
Single
Double
Single
Single
Double
275
375
275
275
375
275
5112A68G02
5112A69G02
4212B60G02
5112A70G02
5112A71G02
4212B61G02
T300K
T350K
T400K
TA300K
TA350K
TA400K
12.50
(317.5)
0.44
(11.2)
0.42
(10.7)
Removable Terminal
Cover Must Be in Place
While in Service
5.05
(128.3)
0.25 (6.4) R
2.28
(58.0)
1.59
(40.6)
CL Handle
0.75
(19.1)
4.26
(108.2)
0.38
(9.7)
1.13
(28.7)
0.30 1.15
(7.6) (29.2)
1.23
(31.2)
1.50
(38.1)
0.25
(6.4)
9.59
(243.6)
10.75
(273.1)
4.38
(111.3)
4.06
(103.1)
3.81
(96.8)
0.38
(9.7)
0.02
(0.5)
1.00 (25.4) x
1.91 (48.5) R Wide
0.22
3.50
(5.6)
(88.9) R
0.50
(12.7)
0.2
TRIP
CL Handle
ON
OFF
19.2
24.2
RESET
0.06
(1.5) R
0.50
(12.7)
0.47
(11.9)
CL Handle
Dimensions
B
On
Off
Tripped
Reset
6.18 (157.0)
4.16 (105.7)
5.30 (134.6)
3.88 (98.6)
6.61 (167.9)
4.58 (116.3)
5.74 (145.8)
4.29 (109.0)
Trough
For
Attachment
Leads
8.21
0.47
(208.5)
(11.9)
1.15
(29.2)
5.14
45
(130.6)
0.06
(1.5)
0.25
(6.4)
3.22
(81.8)
4.33
(110.0)
0.38 3.62 6.69
(9.7) (91.9) (170.0)
45
1.91
(48.5)
Breaker Status
0.53
(13.5)
1.63
(41.4)
1.63
(41.4)
1.91
(48.5)
5.62
(142.7)
0.80 (20.3)
Load End
0.31
(7.9) R
1.38
(35.1)
2.75
(69.9)
2.06
(52.3)
4.13
(104.9)
2.75
(69.9)
5.50
(139.7)
3.64
(92.5)
7.28
(184.9)
4.13
(104.9)
8.25
(209.6)
0.81
(20.6)
4.00
(101.6)
2.29
(58.2)
0.19 (4.8)
Trip Unit May Be
Either Thermal/Magnetic
Or Electronic
3.25
(82.6)
5.09
(129.3)
1.13
(28.7)
4.87
(123.7)
0.25 (6.4) R
3.02 0.16 (4.1) R
(76.7)
8x 0.15 (3.8)
Hole 0.50 (12.7) x
to Accept #8 Thread
Cutting Screws
Line End
9.53
(242.1)
11.34
(288.0)
12x
0.2520 Tap
0.88
(22.4)
Standard Terminals
5.96
(151.4)
Mounting Holes
6.49
(164.8)
Extended Terminals
Terminal Barrier
Used With Extended
Terminals Only (TA603LD)
1.27
(32.3)
1.00 (25.4) x
1.91 (48.5) R Wide
0.53
(13.5)
2.05
(52.1)
Terminal Arrangements
Cable
Type
Wire
Size (kcmil)
Number
of Cables
Torque
(Lb-in)
Style
Number
Catalog
Number
Cu
Cu/Al
Cu/Al
250350
350350
400500
Double
Double
Double
275
275
275
4223B88G11
4223B88G02
4223B89G02
T602LD
TA602LD
TA603LD
4x 0.2520 Tap
Line End
5.05
(128.3)
CL Handle
9.53
(242.1)
Breaker CL
1.06 (26.9)
6x for Three-Pole Breaker
4x for Two-Pole Breaker
Omit Center Pole
Two-Pole Breaker
Load End
1.38
(35.1)
2.75
(69.9)
Line End
5.08
(129.0)
CL Handle
Breaker
9.60
(243.8)
Load End CL
3.44
(87.4)
2.75
(69.9)
1.72
(43.7)
5.50
(139.7)
CL Handle
1.33
(33.8)
Breaker
CL
2.29
(58.2)
R 0.25 (6.4)
1.50
(38.1)
3.64
(92.5)
R 0.19
(4.8)
7.28
(184.9)
Figure 8. Type LG 450600A Three-Pole Cutout and Drilling PlanDimensions in Inches (mm)
eaton corporation www.eaton.com
3.25
(82.6)
0.38 (9.7) Diameter 4 Holes
for 0.3116 x 1.75 (44.4) Lg
Mounting Screws
2.02
(51.3)
0.50
(12.7)
Line End
CL Handle
Pivot
0.55
(14.0)
1.41
(35.8)
Max.
0.81
(20.6)
1.63
(41.4)
1.63
(41.4)
1.87
(47.5)
8.30
(210.8)
6.05
(153.7)
7.68
(195.1)
0.42
(10.7)
On
0.20
14.7
(5.1) Tripped
14.75
(374.7)
Handle
Pivot
Off Reset
19.2
24.2
11.50
(292.1)
16.00
(406.4)
2.75
(69.9)
5.50
(139.7)
1.38
(35.1)
2.75
(69.9)
8.25
(209.5)
2.75
(69.9)
1.38
(35.1)
0.5013
Tap Thru
0.53
(13.5)
0.50
(12.7)
2.53
(64.3)
4.06
(103.1)
4.38
(111.3)
4.13
(104.9)
0.3116 Tap
4 Holes
Load End
1.72
(43.7)
3.44
(87.4)
Breaker
Status
Line End
On
Off
Tripped
Reset
CL Breaker
CL Breaker
7.68
(195.1)
0.25
(6.35)
CL Handle
CL Handle
1.33
(33.8)
8.72 (221.5)
6.72 (170.7)
7.86 (199.6)
6.44 (163.6)
9.17 (232.9)
7.14 (181.4)
8.30 (210.8)
6.84 (173.7)
3.28
(83.3)
1.50
(38.1)
0.19
(4.83)
3.61
(91.7)
0.97
(24.6)
7.28
(184.9)
Load End
Dimensions
Terminal Arrangements
14.75
(374.7)
Cable
Type
Wire
Size (kcmil)
Torque Style
(Lb-in) Number
Catalog
Number
Cu/Al
Cu/Al
Cu/Al
Cu
Cu
375
375
500
300
275
TA700MA1
TA800MA2
TA801MA
T600MA1
T800MA1
672B657G01
672B655G01
1254C01G02
672B653G01
672B651G01
Removable Terminal
Cover Must Be in
Place While in Service
1.06
(26.9)
1.16
(29.5)
0.53
(13.5)
0.5013 Tap
12 Holes
0.53
(13.5)
0.06
(1.5)
Line End
Overall Length
11.58
3.24 (294.1)
(82.3)
9.25
(235.0)
14.75
(374.7)
0.25
(6.4) R
8.62
(218.9)
7.00
(177.8)
11.50
(292.1)
13.20
(335.3)
0.06
(1.5) R
0.09
(2.3) R
0.30
(7.6)
16.00
(406.4)
CL of Terminals
CL of Mounting Holes
0.75
(19.1)
0.95
(24.1)
0.35
(8.9)
14.2OFF
18.2
1.20
(30.5)
3.81
(96.8)
Trough for
Attachment
Lead
19.2
0.2
Tripped
CLHandle
0.38
(9.7)
0.13
(3.3) R
0.13 (3.3) x
0.75 (19.1)
Slots For
Attachment
Leads
2.98
(75.7)
1.03
(26.2)
RESET
B
0.38
(9.7)
A
1.67
(42.4)
2.80
(71.1)
2.51
(63.8)
0.31
(7.9) R
4.13
(104.9)
2.98
(75.7)
Contact Position
Indicator
RedOn/I
GreenOff/O
WhiteTripped
1.38
(35.1)
2.75
(69.9)
Handle
Pivot
2.35
(59.7)
3.34
(84.8)
6.01
(152.7)
8.25
(209.6)
0.78
(19.8)
0.09
(2.3) R
0.06
(1.5) R
4.09
(103.9)
5.06
(128.5)
0.06
(1.5)
1.10
(27.9)
5.19
(131.8)
5.25
(133.4)
5.50
(139.7)
3.38
(85.9)
2.75
(69.9)
1.69
(42.9)
1.56
(39.6)
0.53
(13.5)
Removable Terminal
Cover Must Be in
Place While in Service
8.25
(209.6)
2.00
(50.8)
0.06
(1.5)
Load End
6.00
(152.4)
2.00
(50.8)
7.19
(182.6)
1.00
(25.4)
11
Eaton Corporation
Electrical Sector
1111 Superior Ave.
Cleveland, OH 44114
United States
877-ETN-CARE (877-386-2273)
Eaton.com
2011 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. TD01214004E / Z11056
April 2011