SELECTION GIUDE OF INDUSTRIAL DEHUMIDIFIERS (MANUFACTURED BY TROTEC, GERMANY)

Model No:

8 May 2015

DH 15 AX

DH 30 AX

DH 60 AX

DH 60 AHP

DH 75 AX

DH 110 AX

DH 110 BX

22
11

45
20

90
38

90
25

135
55

150
64

150
64

225

700

1,280

1,280

1,180

1,180

1,180

0
40
30
90

0
40
30
90

0
40
30
90

15
55
20
90

5
40
40
90

5
40
40
90

5
40
40
90

230
50

230
50

230
50

230
50

230
50

230
50

400
50

3,8

3,4

7,5

7,5

6,4

9,3

5,5

18

15,8

30

30

55

66

30

0,43
10

0,75
16

1,2
16

1,2
16

1,5
16

1,9
20

1,9
10

TECHNICAL DATA
Dehumidification performance
At 30 C / 80 % RH [l/24h]
At 20C / 60 % RH [l/24h]

Amount of air
Max. air volume [m/h]

Operating range
Temperature min. [C]
Temperature max. [C]
humidity min. [% RH]
humidity max. [% RH]

Electrical values
Input voltage [V]
Frequency [Hz]
Nominal current consumption
[A]
Required current starting phase
[A]
Max. power input [kW]
Recommended fusing [A]

Electrical connection
Plug type

CEE 7/7

Heat emission
Heat emission [kW]
Coefficient of performance
(C.O.P.)

0,9

1,9

3,5

3,5

5,2

5,2

1,6

2,5

2,9

2,9

2,7

2,5

2,5

R-407C

R-407C

R-407C

R-134a

R-407C

R-407C

R-407C

53

52

54

53

53

53

Compressor
Type of cooling agent

Miscellaneous
Sound pressure level [dB (A)] 1
m
Sound pressure level [dB (A)] 3
m

54

Mobility
Forklift
Rubber-tyred metal wheels

Dimensions (packing excluded)


Length [mm]
Width [mm]
Height [mm]

363
825
320

256
782
648

256
1,247
648

256
1,247
648

385
1,520
796

385
1,520
796

385
1,520
796

33

40

63

70

143

144

144

Weight (packing excluded)


Weight [kg]

Vacker Group
Deira, Dubai
T:+97142661144
sales.uae@vackerglobal.com
www.vackergroup.ae

SELECTION GIUDE OF INDUSTRIAL DEHUMIDIFIERS (MANUFACTURED BY TROTEC, GERMANY)

Model No:

8 May 2015

DH 150 AX

DH 150 BX

DH 150 BX ES

DH 150 BXF

DH 150 BXF ES

DH 300 BH

DH 300 BY

250
110

250
110

250
110

250
110

250
110

520
220

520
220

2,200

2,200

2,200

2,200

2,200

5,800

5,000

0
40
30
90

0
40
30
90

0
40
30
90

0
40
30
90

0
40
30
90

15
70
30
90

-15
40
30
90

230
50

400
50

400
50

400
50

400
50

400
50

400
50

19

8,1

8,1

8,1

8,1

15

TECHNICAL DATA
Dehumidification performance
At 30 C / 80 % RH [l/24h]
At 20C / 60 % RH [l/24h]

Amount of air
Max. air volume [m/h]

Operating range
Temperature min. [C]
Temperature max. [C]
humidity min. [% RH]
humidity max. [% RH]

Electrical values
Input voltage [V]
Frequency [Hz]
Nominal current consumption
[A]
Required current starting phase
[A]
Max. power input [kW]
Recommended fusing [A]

62

42

42

42

42

72

66

2,5
25

2,5
16

2,5
16

2,5
16

2,5
16

5,1
25

6,7
25

CEE 32 A blue

CEE 16 A red

CEE 16 A red

CEE 16 A red

CEE 16 A red

CEE 16 A red

CEE 32 A red

7,4

7,4

7,4

7,4

7,4

10

14,7

3,1

3,1

3,1

3,1

3,1

2,7

3,1

R-407C

R-407C

R-407C

R-407C

R-407C

R-134a

R-407C

Electrical connection
Plug type

Heat emission
Heat emission [kW]
Coefficient of performance
(C.O.P.)

Compressor
Type of cooling agent

Miscellaneous
Sound pressure level [dB (A)] 1
m
Sound pressure level [dB (A)] 3
m

69
58

58

58

58

58

66

660
660
1,313

660
660
1,313

660
660
1,313

660
660
1,313

660
660
1,313

700
985
1,476

826
980
1,475

130

130

130

130

130

170

220

Mobility
Forklift
Rubber-tyred metal wheels

Dimensions (packing excluded)


Length [mm]
Width [mm]
Height [mm]

Weight (packing excluded)


Weight [kg]

Vacker Group
Deira, Dubai
T:+97142661144
sales.uae@vackerglobal.com
www.vackergroup.ae

SELECTION GIUDE OF INDUSTRIAL DEHUMIDIFIERS (MANUFACTURED BY TROTEC, GERMANY)

Model No:

8 May 2015

DH 300 BY F

DH 300 BY ES

DH 300 BY F ES

DH 600 BY

DH 600 BY F

520
220

520
220

520
220

1,040
440

1,040
440

5,000

5,000

5,000

9,000

9,000

-15
40
30
90

-15
40
30
90

-15
40
30
90

-15
40
30
90

-15
40
30
90

400
50

400
50

400
50

400
50

400
50

16

15

16

26

26

TECHNICAL DATA
Dehumidification performance
At 30 C / 80 % RH [l/24h]
At 20C / 60 % RH [l/24h]

Amount of air
Max. air volume [m/h]

Operating range
Temperature min. [C]
Temperature max. [C]
humidity min. [% RH]
humidity max. [% RH]

Electrical values
Input voltage [V]
Frequency [Hz]
Nominal current consumption
[A]
Required current starting phase
[A]
Max. power input [kW]
Recommended fusing [A]

66

66

66

102

102

7,3
25

6,7
25

7,3
25

10
35

10,4
35

CEE 32 A red

CEE 32 A red

CEE 32 A red

CEE 32 A red

CEE 32 A red

14,7

14,7

14,7

29,7

29,7

3,1

2,7

3,1

3,1

3,1

R-407C

R-407C

R-407C

R-407C

R-407C

66

66

66

63

63

826
980
1,475

720
980
1,435

720
980
1,435

1,250
1,730
1,600

1,250
1,730
1,600

220

220

220

497

497

Electrical connection
Plug type

Heat emission
Heat emission [kW]
Coefficient of performance
(C.O.P.)

Compressor
Type of cooling agent

Miscellaneous
Sound pressure level [dB (A)] 1
m
Sound pressure level [dB (A)] 3
m

Mobility
Forklift
Rubber-tyred metal wheels

Dimensions (packing excluded)


Length [mm]
Width [mm]
Height [mm]

Weight (packing excluded)


Weight [kg]

Vacker Group
Deira, Dubai
T:+97142661144
sales.uae@vackerglobal.com
www.vackergroup.ae

You might also like