Ecomag

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

+0,7

6 +0,5

+0,7

6 +0,5

30

30

Control units

26

Linear actuator

165

15 17

15 15

L = S+160

72

MCU

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

SCU 9

SCU 1

SCU 5

26

Ecomag

Ecomag 2-3-6-7

113

ECOMAG
EHA 1

79

EHA 3
STJ
Label position

STA

Benefits

STE
Hand switch
Foot switch
Desk switch

83,4

22,4

15 15

15 17

 $POUSPMVOJUDBOCFNPVOUFEUPUIFBDUVBUPS

72

+0,7

Connecting diagram

25

 4JMFOUPQFSBUJPO

30

30

 $PTUFGGFDUJWF

6 +0,5

+0,7

Label position
6 +0,5

 Compact

L = S+160

24 V DC
+

140

25

Ecomag 4-5-8-9
Rear attachment position
Black

Red
45

45

Limit switches

Legend:
S = stroke
L = retracted length

M
Actuator

90

90

135

135

Push version only

Push and pull version

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

ECO 20/40

ECO 60/80

ECO 30/50

ECO 70/90

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

2 000
0
9 to 13
50 to 300
S+160
24
70
3
10 (1/9)
+10 to +40
4S
2,1
Black or grey

6 000
0
4 to 7
50 to 300
S+160
24
120
5
10 (1/9)
+10 to +40
4S
2,1
Black or grey

2 000
2 000
9 to 13
50 to 300
S+160
24
70
3
10 (1/9)
+10 to +40
4S
2,5
Black or grey

6 000
4 000
4 to 7
50 to 300
S+160
24
120
5
10 (1/9)
+10 to +40
4S
2,5
Black or grey

Linear actuators DC versions

Ordering key

Performance diagrams

Current consumption (A)

Speed (mm/s)
16

16

14

14

12

12

10

10

E C O

2 000

4 000

6 000

8 000

2 000

4 000

Load /Housing:
Pull
Push
2 000 N
0
2 000 N
2 000 N
2 000 N
0
2 000 N
2 000 N
6 000 N
0
6 000 N
4 000 N
6 000 N
0
6 000 N
4 000 N

6 000

8 000

Housing
Large
Large
Small
Small
Large
Large
Small
Small

2
3
4
5
6
7
8
9

Encoder:
No encoder, coiled cable, 2-pin Minifit plug or customization
No encoder, coiled cable , DIN8 plug or customization
2-Hall encoder, 8 pulses, straight cable, DIN8 plug (small housing only)

ECO 20 / 30 / 40 / 50
ECO 60 / 70 / 80 / 90

Speed-load diagram

0 0 0

Load (N)

Load (N)

ECO 20 / 30 / 40 / 50
ECO 60 / 70 / 80 / 90

Type

0
0

Ecomag

Ecomag

0
9
F

Current-load diagram

Current cut-off:
No
Yes (not available for ECO4.-/ECO5.-/ECO8.-/ECO9.-)

0
1

Stroke (S):
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
Other stroke lengths; 50<S<300 mm

Safety factor load conditions

05
10
15
20
25
30
00

Push load (N)

Front attachment (groove depth 17 mm):


Hole, =12 mm, groove width 10 mm
Customized

6 000

M
X

4 500

Rear attachment (groove depth 15 mm):


Hole, =12 mm, groove width 10 mm
Customized

3 000

M
X

Orientation of rear attachment:


0
45
90
135

1 500

1
3
5
7

0
0

100

200

300

Color:
Black
Grey

400

Stroke length (mm)

Push load reduction


Safety factor=4

A
B

Option:
No option
Back-up nut (available only for drives with 6 kN, mandatory for UL 2601) only for ECO 7/9, L = +23 mm
FOR ECO3,-/ECO5.-ONLY (no back-up nut)
Quick-release, push load, fork head bore parallel to lever, L = +40 mm, integrated anti-pinching protection.
Quick-release, push load, bore 90 to lever, L = +40 mm, integrated anti-pinching protection.
Quick-release, pull load, fork head bore parallel to lever, L = +40 mm, integrated anti-pinching protection.
Quick-release, pull load, fork head bore 90 to lever, L = +40 mm, integrated anti-pinching protection.
Mechanical anti-pinching protection pull, motor direction push, L = +13 mm.
Mechanical anti-pinching protection push, motor direction pull, L = +13 mm.

0
A

B
C
F
G
K
L

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5301,2400 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Runner

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

Stroke

L+30

Control units

12

+0,3
+0,1
+0,3
12 +0,1

* Retracted length:

RU20, RU21, RU22

up to 500 mm stroke: stroke +215 mm (plus options)


from 500 mm stroke: stroke +315 mm (plus options)

RU23, RU24, RU25

Runner

Stroke

30

53

30

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

SCU 9

SCU 5

SCU 1

Linear actuator

33,6

L = S + 215/315* (+-2 mm)

EHA 3
STJ
15

STE

12

14

15

Benefits

28

80

28
11

11

Hand switch
Foot switch
Desk switch

Connecting diagram

 High push/pull load

189

23

 Compact
45

90

 Silent operation

95

30,7

24 V DC
+

94

 High safety factor

47

 Back-up nut as standard

53

135
168

Rear attachment position


Black

Red

Limit switch

Legend:
S = stroke
L = retracted length

M
Actuator

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
Color

1)
2)

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

RU20

RU21

RU 22

RU23

RU24

RU25

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

8 000
8 000
7 to 10
100 to 700
S+215/3152)
24
N/A
7
10 (1/9)
+10 to +40
4/6S
4,7
Grey

10 000
8 000
5 to 8
100 to 700
S+215/3152)
24
N/A
7
10 (1/9)
+10 to +40
4/6S
4,7
Grey

12 0001)
8 000
4 to 7
100 to 700
S+215/3152)
24
N/A
7
10 (1/9)
+10 to +40
4/6S
4,7
Grey

8 000
8 000
8 to 15
100 to 700
S+215/3152)
24
N/A
10
10 (1/9)
+10 to +40
4/6S
4,7
Grey

10 000
8 000
6 to 12
100 to 700
S+215/3152)
24
N/A
10
10 (1/9)
+10 to +40
4/6S
4,7
Grey

12 0001)
8 000
5 to 9
100 to 700
S+215/3152)
24
N/A
10
10 (1/9)
+10 to +40
4/6S
4,7
Grey

Safety working load for medical application is 10 000 N (EN 60601)


S 500 mm; L = S + 215
S > 500 mm; L = S + 315

Linear actuators DC versions

Runner

Runner
Ordering key

Performance diagrams

R U 2
Speed (mm/s)
14

12

10

Voltage:
24 V DC

RU 22

5
RU 20

Load / Speed:
8 000 N / 7-10 mm/s
8 000 N / 8-15 mm/s
10 000 N / 5-8 mm/s
10 000 N / 6-12 mm/s
12 000 N / 4-7 mm/s
12 000 N / 5-9 mm/s

4
6

RU 21

RU 22

1
0

0
0

4 000
2 000

8 000
6 000

12 000
10 000

0
14 000

4 000
2 000

6 000

8 000
12 000
16 000
10 000
14 000

Load (N)

Current-load diagram

Speed (mm/s)

Current consumption (A)

16

10

14

RU 24
RU 23
7

RU 23

0
3
1
4
2
5

Stroke (S) / Retracted length (L):


50 mm / 315 mm
100 mm / 315 mm
150 mm / 365 mm
200 mm / 415 mm
250 mm / 465 mm
300 mm / 515 mm
350 mm / 565 mm
400 mm / 615 mm
450 mm / 665 mm
500 mm / 715 mm
550 mm / 865 mm
600 mm / 915 mm
650 mm / 965 mm
700 mm / 1 015 mm
50<S500 mm / S+215
500<S<700 mm / S+315
S>700 mm (customized)

Load (N)

Speed-load diagram

12

0 0

Type

RU 21
RU 20

Current consumption (A)

6
10

050315
100315
150365
200415
250465
300515
350565
400615
450665
500715
550865
600915
650965
7 0 0 XXX
----------XXXXXX

5
8
RU 24

Type of protection / Color:


IP4S, grey
IP6S, grey

RU 25

6
3

RU 25
4

Cable:
Straight cable, 1,5 m, DIN8 plug
Straight cable, 1,5 m, Jack plug 180

0
0

4 000
2 000

8 000
6 000

12000
10 000

14000

2 000

4 000

6 000

8 000
12 000
16 000
10 000
14 000

Load (N)

Current-load diagram

0
2
4
6

Option 1:
No option
Electrical anti-pinching (safety switch), pull load, L+20 mm
Electrical anti-pinching (safety switch), push load, L+20 mm

Safety factor load conditions


Load (N)

0
K
L

Load (N)

14 000

Option 2:
No option
2-Hall encoder, 14 pulses, DIN8 plug
Lifetime monitoring
2-Hall encoder, 14 pulses, DIN8 plug, lifetime monitoring

14 000
RU21
RU22
RU24
RU25

12 000

12 000
RU22
RU25

10 000

10 000

8 000

RU21
RU24
RU20
RU23

6 000

4 000

4 000

2 000

2 000

0
A
M
N

Option 3:
No option
Emergency lowering, L+53 mm (for push load only)

8 000
RU20
RU23

6 000

15
0D

Rear attachment orientation / Hole diameter:


0 / =12,0 mm
45 / =12,0 mm
90 / =12,0 mm
135 / =12,0 mm

Load (N)

Speed-load diagram

A
B

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

0
0

100

200

300

400

500

600

700

100

200

300

400

500

600

700

1)

1)

Stroke (mm)

Stroke (mm)

SKF is a registered trademark of the SKF Group

Push load limit, safety factor S=4


(EN 60601) 1) retracted length extension
at stroke >500 mm

SKF Group 2011


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

Push load limit, safety factor S=2


1) retracted length extension
at stroke >500 mm

PUB L5321,2540 EN October 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Matrix 1

Linear actuators DC versions


Dimensional drawing

Control units

29

31

Suitable control units and accessories

MCU

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

SCU 9

Linear actuator

SCU 5

SCU 1

12+0,3
+0,15

12

+0,3
+0,1

DIN8 plug

MAX 1

Side view

EHA 1

66

EHA 3

Matrix 1

STJ
STA
STE
Hand switch
Foot switch
Desk switch

Benefits

L2*
14

15

12

116

15

24 V DC
+
5V+

28

11

28

11

Connecting diagram*

Silent operation
Top view

* S < 350 mm; L = 195 + S


S > 350 mm; L = 260 + S

GND

Blue

Red

Rear view

3 5 6 8

2 Hallsensors signal

169

2+4

48

Hall A
Hall B

DIN8 plug
1+7

107

1,5K

40

1,5K

Rear attachment position

Actuator

* Only valid for MAX 11. MAX 10 must be operated by a

66

BCU, MCU, SCU or VCU control unit.

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

* S<350 mm, L = 195 + S


S>350 mm, L = 260 + S

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

MAX 1..A..

MAX 1..B..

MAX 1..C..

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

4 000
4 000
5 to 7
50 to 700
S + 195/260*
24
120
5
10 (1/9)
0 to +40
66S
4,0
Grey

2 000
2 000
6 to 9
50 to 700
S + 195/260*
24
120
5
10 (1/9)
0 to +40
66S
3,7
Grey

1 500
1 500
12,7 to 18
50 to 700
S + 195/260*
24
120
5
10 (1/9)
0 to +40
66S
3,6
Grey

Label

Linear actuators DC versions

Matrix 1

Matrix 1
Ordering key

Performance diagrams

MA X 1
Speed (mm/s)

0 0 0

Current consumption (A)


10,0

20

Type
C

Voltage:
24 V DC
24 V DC with integrated current cut-off

7,5

15

10

5,0

Load:
4 000 N
2 000 N
1 500 N

2,5

0
1 000

2 000

3 000

4 000

1 000

2 000

3 000

Load (N)

4 000

Load (N)

Speed-load diagram

Current-load diagram

Safety factor load conditions

Load (N)

Load (N)

8 000

3 500

7 000

7 000

3 000

6 000

6 000
5 000

5 000
4 000

4 000

1 500

3 000

3 000
B

C pull/push

2 000

2 000

1 000

1 000

500

100

200

300

400

500

600

700

800

0
0

100

200

300

400

500

600

700

800

Stroke (mm)

Stroke (mm)

Push load reduction static


Safety factor S=1

1 000

Push load reduction static


Safety factor S=2

EKZm: mechanical anti-pinching


0

100

200

0
1
2

Option 1:
No option, only valid for actuator "A" (push and pull)
Quick-release +EKZm, push, fork head bore parallel to button (for actuator design "C" is L= +115 mm)*
Quick-release +EKZm, push, fork head bore 90 to button (for actuator design "C" is L= +115 mm)*
Mechanical anti-pinching, motor direction pull, no fixing in term. position (for load A, L= +45 mm; Band C, L= +30 mm)
Mechanical anti-pinching, motor direction push, no fixing in term. position (for load A, L= +45 mm; Band C, L= +30 mm)
Push load, for actuator version "B" and "C"
Pull load, for actuator version "B" and "C"

B pull/push
2 000

0B
C5
--

Orientation of rear attachment:


No fork head (customized option)
Standard (as drawing)
Turned 90

A pull/push

2 500

050 245
100 295
150 345
200 395
250 445
300 495
350 545
400 660
450 710
500 760
550 810
600 860
650 910
700 960
--- ---

Cable / Connecting plug:


Coiled, 0,75 m (not stretched) / DIN8 plug
Straight, 2,5 m / DIN8 plug
Special cable length on request

Load (N)

8 000

4 000

A
B
C

Stroke (S):
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm
650 mm
700 mm
Other stroke lengths; 50<S<700 mm

0
0

0
1

300

400

500

600

700

0
E
F
I
J
M
N

*min. stroke 150 mm up to 300 mm

800

Stroke (mm)

Option 2:
No option
2-Hall encoder, DIN8 plug
Lifetime monitoring
Lifetime monitoring, 2-Hall encoder, DIN8 plug

Push load reduction static


Safety factor S=4 (EN60601)

0
F
M
P

Option 3:
No option
Emergency lowering, fork head bore parallel to clamping lever (for actuator design "A", L+30 mm)
Emergency lowering, fork head bore 90 to clamping lever (for actuator design "A", L+30 mm)

V
W

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2510 EN May 2010

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Matrix 3

Linear actuators DC versions

Control units

29

42,5

Dimensional drawing

31

Suitable control units and accessories

+0,3

MAX 3

+0,3

12 +0,1

MCU

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

SCU 9

Linear actuator

SCU 5

SCU 1

12 +0,1

DIN8 plug

EHA1

82

Side view

EHA3

Matrix 3

STJ
S

STA

L 2*

STE

14
15

12

136

15

28

28

Benefits

11

11

Hand switch
Foot switch
Desk switch

Connecting diagram*

Silent operation

Top view

* S < 350 mm; L = S + 215


S > 350 mm; L = S + 280

Full system with control unit,


operating switch and accessories

12/24 V DC
+
5V+

122
112
50

GND

Compact and aesthetic

Hall A
Hall B

DIN8 plug

Back-up nut as standard

1+7

2+4

Blue

Red

1,5K
40

1,5K

Rear view

3 5 6 8

192

Synchronization possible

Rear attachment position


Standard 0
Turned 90
M

2 Hallsensors signal

Actuator
Label
82

* Only valid for MAX 31. MAX 30 must be operated by a


BCU, MCU, SCU or VCU control unit.

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

1)
2)

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

MAX 3..A..

MAX 3..B..

MAX 3..C..

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

8 000
6 0001)
5 to 7
50 to 700
S + 215/2802)
12 or 24
120
5,0
10 (1/9)
0 to +40
66S
4,5
Grey

4 000
4 000
6 to 9
50 to 700
S + 215/2802)
12 or 24
120
5,0
10 (1/9)
0 to +40
66S
4,2
Grey

3 000
3 000
12,7 to 18
50 to 700
S + 215/2802)
12 or 24
120
5,0
10 (1/9)
0 to +40
66S
4,0
Grey

Max load for medical application is 5 000 N


S 350 mm; L = S + 215
S > 350 mm; L = S + 280

Linear actuators DC versions

Matrix 3

Matrix 3
Ordering key

Performance diagrams

MA X 3
Speed (mm/s)

0 0 0

Current consumption (A)


10,0

20

Type
C

15

Voltage:
24 V DC
24 V DC with integrated current cut-off
12 V DC

7,5

5,0

10

Load:
8 000 N
4 000 N
3 000 N

A
2,5

0
2 000

6 000

4 000

8 000

2 000

4 000

6 000

Load (N)

8 000

Load (N)

Speed-load diagram

Current-load diagram

Safety factor load conditions

Load (N)

Load (N)

Orientation of rear attachment:


No fork head (customized option)
Standard (as drawing)
Turned 90

7 000

7 000
A

A pull

6 000

6 000

6 000

B pull/push
C pull

C push

1 000

3 000

3 000

3 000

2 000

2 000

1 000

1 000

100

200

300

400

500

600

700

800

100

200

300

400

500

600

700

800

Stroke (mm)

Stroke (mm)

Push load reduction static


Safety factor S=1

Push load reduction static


Safety factor S=2

100

200

0
1
2

Option 1:
No option, only valid for actuator "A" (push and pull)
Quick-release +EKZm, push, fork head bore parallel to button (for actuator design "C" is L= +115 mm)*
Quick-release +EKZm, push, fork head bore 90 to button (for actuator design "C" is L= +115 mm)*
Electrical anti-pinching protection, motor direction pull
Electrical anti-pinching protection, motor direction push
Push load, for actuator version "B" and "C"
Pull load, for actuator version "B" and "C"

4 000

4 000

4 000

2 000

5 000

5 000

5 000

0B
C5
--

8 000

A push
7 000

050 265
100 315
150 365
200 415
250 465
300 515
350 565
400 680
450 730
500 780
550 830
600 880
650 930
700 980
--- ---

Cable / Connecting plug:


Coiled, 0,75 m (not stretched) / DIN8 plug
Straight, 2,5 m / DIN8 plug
Special cable length on request

Load (N)

8 000

8 000

A
B
C

Stroke (S):
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm
650 mm
700 mm
Other stroke lengths; 50<S<700 mm

0
0

0
1
2

300

400

500

600

700

800

EKZm: mechanical anti-pinching

0
E
F
K
L
M
N

*min. stroke 150 mm up to 300 mm

Stroke (mm)

Option 2:
No option
2-Hall encoder, DIN8 plug
Lifetime monitoring
Lifetime monitoring, 2-Hall encoder, DIN8 plug

Push load reduction static


Safety factor S=4 (EN60601)

0
F
M
P

Option 3:
No option
Emergency lowering, fork head bore parallel to clamping lever (for actuator design "A", L+30 mm)
Emergency lowering, fork head bore 90 to clamping lever (for actuator design "A", L+30 mm)

V
W

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2520 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Matrix 6

Linear actuators AC versions

29

42,5

Dimensional drawing

31

Suitable control units and accessories

+0,3

12 +0,1

Side view

+0,3

12 +0,1

Mains cable

Linear actuator

L2*

PAM

STA

PFP

STF

Matrix 6

PHC 1

EHA 1

85
S

14
136

MAX 6 Integrated control unit

15

15

12

Connecting diagram

Top view

28

11

28

11

Hand switch
Foot switch
Desk switch

* S < 350 mm; L = S + 215


S > 350 mm; L = S + 280

123
112
120/230 V AC

PE

50

40,5

Operating
device

Rear attachment position


Standard 0
Turned 90

192,5

Label

M
135

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
120 V AC
230 V AC
Current consumption 120 V AC
230 V AC
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color
1)
2)

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Max load for medical application is 5 000 N


S < 350 mm; L = S + 215
S > 350 mm; L = S + 280

Unit

MAX 6..A..

MAX 6..B..

MAX 6..C..

N
N
mm/s
mm
mm
V AC
W
W
A
A
%
C
IP
kg

8 000
6 0001)
6 to 7,5
50 to 700
S + 215/2802)
120 or 230
150
145
1,8
0,9
10 (1/9)
0 to +40
66S
4,8
Grey

4 000
4 000
8 to 10
50 to 700
S + 215/2802)
120 or 230
150
145
1,8
0,9
10 (1/9)
0 to +40
66S
4,5
Grey

3 000
3 000
13 to 18
50 to 700
S + 215/2802)
120 or 230
150
145
1,8
0,9
10 (1/9)
0 to +40
66S
4,2
Grey

Linear actuators AC versions

Matrix 6

Matrix 6
Ordering key

Performance diagrams

Speed (mm/s)

Current consumption (A)


2,0

20

MA X 6

C (120 V)

15

B (120 V)

Voltage:
230 V AC/50 Hz, integrated pneumatic control
120 V AC/60 Hz, integrated pneumatic control
230 V AC/50 Hz, integrated low voltage control with additional 24 V output
120 V AC/60 Hz, control +1 channel with additional 24 V output
230 V AC/50 Hz, integrated low voltage
120 V AC/60 Hz, integrated low voltage

B (230 V)

A
0,5

A (230 V)

0
2 000

4 000

6 000

8 000

2 000

4 000

6 000

8 000

Load (N)

Load:
8 000 N
4 000 N
3 000 N

Current-load diagram

Load (N)

Load (N)

Load (N)

8 000

8 000

A push
7 000

7 000

7 000
A

A pull
6 000

6 000

5 000

5 000

6 000

4 000

4 000

C pull
3 000
C push

1 000

3 000

2 000

2 000

1 000

1 000

0
300

400

500

600

700

800

100

200

300

400

500

600

Stroke (mm)

700

800

100

Stroke (mm)

Push load reduction static


Safety factor S=1

Cable/Connecting plug:
No cable

200

300

400

500

600

700

800

Stroke (mm)

Push load reduction static


Safety factor S=2

Push load reduction static


Safety factor S=4 (EN60601)

Plug

Country

Designation

Order number

Straight cable 3,5 m


Straight cable 3,5 m
Straight cable 3,5 m
Straight cable 3,5 m
Straight cable 3,5 m
Coiled cable 1,2 m / 2,2 m
Coiled cable 1,2 m / 2,2 m
Straight polyurethane cable 3,5 m
Straight polyurethane cable 3,5 m
Strain relief for mains cable
Tool for plugs (Jack/DSub/Mains)

Schuko
SEV
UL
Hospital grade
British standard
Schuko
SEV
SEV
Schuko

DE
CH
USA
USA
UK
DE
CH
CH
DE

ZKA1403063500
ZKA1403163500
ZKA1403553500
ZKA1403603500
ZKA1403503500
ZKA1403421500
ZKA1403781200
ZKA1404223500
ZKA1404263500
ZUB952253
ZWS140375

M/0121723
M/0121737
M/0121724
M/0121732
M/0121743
M/0121728
M/0121738
M/0121739
M/0121740
M/0102848
M/0125322

0
1
2

Option 1:
No option, only valid for actuator "A"
Quick-release +EKZm, push, fork head bore parallel to button (for actuator design "C" is L= +115 mm)*
Quick-release +EKZm, push, fork head bore 90 to button (for actuator design "C" is L= +115 mm)*
Electrical anti-pinching protection, motor direction pull
Electrical anti-pinching protection, motor direction push
Push load, for actuator version "B" and "C"
Pull load, for actuator version "B" and "C"
EKZm: mechanical anti-pinching
*min. stroke 150 mm up to 300 mm

Accessories
Description

Orientation of rear attachment:


No fork head (customized option)
Standard (as drawing)
Turned 90

0
0

050 265
100 315
150 365
200 415
250 465
300 515
350 565
400 680
450 730
500 780
550 830
600 880
650 930
700 980
--- ---

3 000

2 000

0
200

5 000
B

B pull/push
4 000

A
B
C

Stroke (S):
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm
650 mm
700 mm
Other stroke lengths; 50<S<700 mm

Safety factor load conditions

8 000

0
1
2
3
4
5

Load (N)

Speed-load diagram

100

0 0 0

Type

A (120 V)

C (230 V)

1,0

10

1,5

Option 2:
No option
Lifetime monitoring

0
E
F
K
L
M
N
0
M

Option 3:
No option
Emergency lowering, fork head bore parallel to clamping lever (for actuator design "A", L+30 mm)
Emergency lowering, fork head bore 90 to clamping lever (for actuator design "A", L+30 mm)

V
W

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2532 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magdrive

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

L= 1 500 mm
+0,3

12 +0,1

+0,3

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

SCU 9

SCU 1

Linear actuator

SCU 5

29

31

12 +0,1

62

MAGDRIVE
EHA 3

Magdrive

L = S + 465/4892

STJ

27

15 15

28
11

11
28

15 12

STE

Benefits

Connecting diagram

 Slim design

Plastic bushing for forkhead


(hinge delivered separately)

 Aluminium profile

Orientation of
rear attachment
Standard 0

 In-line actuator

25

 Quiet operation

10

24 V DC
+
26

 High push load

0
1

8,7

2
1

Legend:
S = stroke
L = retracted length

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

MD22/MD24

MD23/MD25

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

6 000
200* (static only)
8,5 to 15
50 to 700
S+465
24
N/A
7
10 (1/9)
+10 to +40
0/4S
5,0
Colorless anodized

6 000
6 000
8,5 to 15
50 to 700
S+489
24
N/A
7
10 (1/9)
+10 to +40
0/4S
5,0
Colorless anodized

90 turned

Linear actuators DC versions

Ordering key

Performance diagrams

Speed (mm/s)

Current consumtion (A)

16

14

12

10

0
0

Magdrive

Magdrive

MD 2

0 0

Type
Push/pull force:
6 000 N/200 N
6 000 N/6 000 N
6 000 N/200 N (recommended for
medical applications- with alu. rear hinge)
6 000 N/6 000 N (recommended for
medical applications- with alu. rear hinge)

1 000 2 000 3 000 4 000 5 000 6 000 7 000 8 000

0 1 000 2 000 3 000 4 000 5 000 6 000 7 000 8 000

Load (N)

Load (N)

2
3
4
5

Stroke:
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm
650 mm
700 mm
Other stroke lengths

Current-load diagram

Speed-load diagram

050
100
150
200
250
300
350
400
450
500
550
600
650
700
___

Retracted length:
MD22/24: S+465 mm
MD23/25: S+489 mm
Over 1 000 mm assembly length, use customer specific adaption
Others

Safety factor load conditions

___
___
XXX
___

Type of protection:
IPX0
IPX4S
Load (N)

Load (N)

8 000

8 000

8 000

7 000

7 000

7 000

6 000

6 000

5 000

5 000

4 000

4 000

3 000

3 000

3 000

2 000

2 000

2 000

1 000

1 000

1 000

MD 22-25

6 000
MD 24/25

5 000
4 000

Motor cable:
Straight, 1,5 m, DIN8 plug
Straight, 1,5m, jack plug 180

100

200

300

400

500

600

700

800

Stroke (mm)

Push load diagram


Safety factor S=2
Safety factor according
UL606011, IEC606011
Safety factor according
UL606011, IEC606011

100

200

300

400

500

600

700

800

Stroke (mm)

Pull load diagram MD23


Safety factor S=4
Safety factor according
UL606011, IEC606011

0
4

Option 1:
No option
Electrical anti-pinching protection, safety switch, motor direction push
Electrical anti-pinching protection, safety switch, motor direction pull

100

200

300

400

500

600

700

0
L
K

Option 2:
No option
Dual encoder (only available with DIN8 plug) 2,15 impulse per turn/sensor (= 5,375 imp. per 1 mm.)

0
0

15
0D

Rear attachment / Hole diameter:


Standard 0 / 12 mm
Rotated 90 / 12 mm

MD 22/23

A
B

Load (N)

800

0
F

Stroke (mm)

Option 3:
No option
Emergency lowering fork head bore (add 30 mm to retracted length "L")

Pull load diagram MD25 (6 000 N)


Safety factor according
UL606011, IEC606011

Options written in italic fonts are only available on demand. Please contact SKF.

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2590 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce WSP

Linear actuators AC versions

Connecting diagram

Dimensional drawing

122
90

230 V AC
L
N
PE

56

30

10 H8

12 ++ 0,09
0,04

PG clamp range
4 10

Linear actuator

44
10

Free-wheel-brake on request
72
120
Retracted length = stroke + 230 mm

Magforce WSP

Stroke + 255

Stroke

Side view

25
16

20
30

Benefits

10H11

Modular

60

Top view

72,5

Robust
Reliable
127
108

High speed and/or high load

90

161

199

31

228

All metal design

Rear view

48

Technical data

Push load
Pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

1)Push
2)Push

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

WSP 0510

WSP 1030

WSP 1550

WSP 2650

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

500
500
50
100 to 700
S+230
230
230
1,1
25 (2,5/7,5)
10 to +40
54
5,5
Silver

1 000
1 000
18
100 to 700
S+230
230
200
1
25 (2,5/7,5)
10 to +40
54
5,5
Silver

1 5001)
1 500
10
100 to 700
S+230
230
200
1
25 (2,5/7,5)
10 to +40
54
5,5
Silver

2 6002)
2 600
5
100 to 700
S+230
230
230
1,1
25 (2,5/7,5)
10 to +40
54
5,5
Silver

load allowed up to 650 mm stroke (if S>650 mm, only pull load is allowed)
load allowed up to 500 mm stroke (if S>500 mm, only pull load is allowed)

Linear actuators AC versions

Magforce WSP

Magforce WSP

Performance diagram

Ordering key

Safety load factor conditions

WS P
Speed (mm/s)

Stroke (mm)
800

60

Type

Add. guiding
recommended

700
50

Load:
500 N
1 000 N
1 500 N
2 600 N

600
40

S=4

500
400

30

0510
1030
1550
2650

300
20
200
10
100

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

Standard
guiding

0
0

500

1 000

1 500

2 000

2 500

3 000

Load (N)

Speed-load diagram

Load (kN)

WSP 0510-200
WSP 1030-200
WSP 1550-200
WSP 2650-200

Bending of spindle
S = safety factor Euler 3

100
200
300
400
500
600
700

Option 1:
No option
Others*

01
XX

Option 2:
No option
Free wheel brake on push load, 1028, 6228
Free wheel brake on pull load, 1028, 0002
Friction brake for pull/push load, 1028, 7851

0
A
B
C

Option 3:
No option
Limit switch

Options

0
1

Options shown in italics are only available on request.


Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: WSP103010001.
Example for ordering an actuator with option limit switch: WSP10301000101 (01= with limit switch).
* Example for others XX: Add. guiding bush - L=S+280 mm, protection tube made out of stainless steel, bronze nut, low temp grease 30,
extended motorshaft, rear attachment hole turned 90, without rear attachment; motor turned 90.

Spare parts
4 holes thread
M 6 9 mm deep

20

15

25

12
11

Retracted length = stroke + 203 mm

31

Extended motor shaft

Description

Designation

Order N

Limit switch 100 mm stroke


Limit switch 200 mm stroke
Limit switch 300 mm stroke
Limit switch 400 mm stroke
Limit switch 500 mm stroke
Limit switch 600 mm stroke

1043,0209100
1043,0209200
1043,0209300
1043,0209400
1043,0209500
1043,0209600

M/0126964
M/0126965
M/0126966
M/0126967
M/0126968
M/0126969

Rear screw fixing

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2110 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce DSP

Linear actuators AC versions

Connecting diagram

Dimensional drawing

127
90

3x400 V AC
L1
L2
L3
N
PE

Linear actuator

K1
10H8

K2
K1

56

K2

30
12 +0,09
+0,04

K2
K1

44

Magforce DSP

Free-wheel-brake on request

10

72
120

Retracted length = stroke + 230 mm

M
3

Stroke + 255

Stroke

25
16

Modular

30

20

Benefits

10H11

Side view

Robust

72,5

Reliable

Top view

High speed and/or high load

108
90

219

190

152

All metal design

Rear view

48

Technical data

Push load
Pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

1)Push
2)Push
3)Push

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

DSP 1010

DSP 2530

DSP 3250

DSP 4550

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

1 000
1 000
50
100 to 700
S+230
3400
210
0,5
40 (4/6)
10 to +40
54
5,6
Silver

2 5001)
2 500
15
100 to 700
S+230
3400
260
0,6
40 (4/6)
10 to +40
54
5,6
Silver

3 2002)
3 200
10
100 to 700
S+230
3400
260
0,6
40 (4/6)
10 to +40
54
5,6
Silver

4 5003)
4 500
5
100 to 700
S+230
3400
280
0,6
40 (4/6)
10 to +40
54
5,6
Silver

load allowed up to 500 mm stroke (if S>500 mm, only pull load is allowed)
load allowed up to 450 mm stroke (if S>450 mm, only pull load is allowed)
load allowed up to 350 mm stroke (if S>350 mm, only pull load is allowed)

Linear actuators AC versions

Magforce DSP

Magforce DSP

Performance diagram

Ordering key

Safety load factor conditions

D S P
Speed (mm/s)

Stroke /mm)
800

60

Add. guiding
recommended

700

50

Type
Load:
1 000 N
2 500 N
3 200 N
4 500 N

600
40
500
30

S=4

400
300

20

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

200

10

Standard
guiding

100
0
0

1 000

2 000

3 000

4 000

5 000

Load (N)

Load (kN)

DSP 1010-200
DSP 2530-200
DSP 3250-200
DSP 4550-200

Speed-load diagram

1010
2530
3250
4550
100
200
300
400
500
600
700

Option 1:
No option
Others*

Bending of spindle
S = safety factor Euler 3

01
XX

Option 2:
No option
Free wheel brake on push load, 1028, 6226
Free wheel brake on pull load, 1028, 0002
Friction brake for pull/push load, 1028, 7851

0
A
B
C

Option 3:
No option
Limit switch

Options

0
1

Options shown in italics are only available on request.

4 holes thread
M6 9 mm deep

Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: DSP101010001.
Example for ordering an actuator with option limit switch: DSP10101000101 (01= with limit switch).
* Example for others XX: Add. guiding bush - L=S+280 mm, protection tube made out of stainless steel, bronze nut, low temp grease -30,
extended motorshaft, rear attachment hole turned 90, without rear attachment; motor turned 90.

25
15

Spare parts

20
12
11

Retracted length = stroke + 203 mm

Designation

Order N

ZAC1043,02100100
ZAC1043,02100200
ZAC1043,02100300
ZAC1043,02100400
ZAC1043,02100500
ZAC1043,02100600

M/0126970
M/0126971
M/0126972
M/0126973
M/0126974
M/0126975

31

Extended motor shaft

Limit switch 100 mm stroke


Limit switch 200 mm stroke
Limit switch 300 mm stroke
Limit switch 400 mm stroke
Limit switch 500 mm stroke
Limit switch 600 mm stroke

Rear screw fixing

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2120 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce ASM

Linear actuators DC versions

Connecting diagram

Dimensional drawing

80
78

30

10 H8

56

Linear actuator

12 ++ 0,09
0,04

2 x 1,5 mm2 x 500 mm


12/24 V DC
+

44

Magforce ASM

Free-wheel-brake on request

10

72
120

Retracted length = stroke + 230 mm

Stroke + 255

Stroke

ASM

Side view

Modular

25

16

20
30
10H11

Benefits
Robust

72,5

Reliable

Top view

High speed and/or high load

103

165

203

225

All metal design


31

Rear view
48

Legend:
S = stroke
L = retracted length

Technical data

Push load
Pull load
Speed (at full load)

12 V DC
24 V DC
Stroke
Retracted length
Voltage
Power consumption 12 V DC
24 V DC
Current consumption 12 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight
Color
1)Push
2)Push
3)Push

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

ASM 1010

ASM 2030

ASM 3030

ASM 4050

N
N
mm/s
mm/s
mm
mm
V DC
W
W
A
A
%
C
IP
kg

1 000
1 000
50
45
100 to 700
S+230
12 or 24
192
192
16
8
10 (1/9)
10 to +40
44
5
Silver

2 0001)
2 000
17
18
100 to 700
S+230
12 or 24
168
144
14
6
10 (1/9)
10 to +40
44
5
Silver

3 0002)
3 000
8
8
100 to 700
S+230
12 or 24
168
168
14
7
10 (1/9)
10 to +40
44
5
Silver

4 0003)
4 000
5
5
100 to 700
S+230
12 or 24
168
168
14
7
10 (1/9)
10 to +40
44
5
Silver

load allowed up to 600 mm stroke (if S>600 mm, only pull load is allowed)
load allowed up to 450 mm stroke (if S>450 mm, only pull load is allowed)
load allowed up to 400 mm stroke (if S>400 mm, only pull load is allowed)

Linear actuators DC versions

Magforce ASM

Magforce ASM
Ordering key

Performance diagrams

A SM
Speed (mm/s)
80

70

70

60

60

50

50

40

40

30

30

20

20

10

10

4 000

3 000

2 000

1 000

Speed (mm/s)

80

Load (N)

Speed-load diagram at 12 V DC

ASM 1010
ASM 2030
ASM 3030
ASM 4050

Type
Load:
1 000 N
2 000 N
3 000 N
4 000 N

1 000

2 000

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

4 000

3 000

1010
2030
3030
4050

Load (N)

Speed-load diagram at 24 V DC

100
200
300
400
500
600
700

Option 1:
12 V DC
24 V DC
Others*

01
02
XX

Option 2:
No option
Free wheel brake on push load, 1028,6226
Free wheel brake on pull load, 1028, 0002
Friction brake for pull/push load, 1028, 7851
Safety factor load conditions

0
A
B
C

Option 3:
No option
Limit switch

Stroke (mm)

0
1

Options shown in italics are only available on request.

800
F

Add. guiding
recommended

700

Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: ASM101010001.
Example for ordering an actuator with option limit switch: ASM10101000101 (01= with limit switch).
* Example for others XX: Add. guiding bush - L=S+280 mm, protection tube made out of stainless steel, bronze nut, low temp grease 30,
extended motorshaft, rear attachment hole turned 90, without rear attachment; motor turned 90.

600
500

S=4

400
300
200
100

Standard
guiding

0
1

Spare parts

Load (kN)

Designation

Order N

ZAC1043,02100100
ZAC1043,02100200
ZAC1043,02100300
ZAC1043,02100400
ZAC1043,02100500
ZAC1043,02100600

M/0126970
M/0126971
M/0126972
M/0126973
M/0126974
M/0126975

Bending of spindle
S = safety factor Euler 3

Limit switch 100 mm stroke


Limit switch 200 mm stroke
Limit switch 300 mm stroke
Limit switch 400 mm stroke
Limit switch 500 mm stroke
Limit switch 600 mm stroke

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2130 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce STW

Linear actuators AC versions

Dimensional drawing

54

116

56

116

140
35

Linear actuator

79
16F7

174

69

40

PG 16 clamprange 815

20
95

67

Retracted length = stroke + 273


Stroke

Rear view

Stroke + 293

Side view

Limit switches or potentiometer on request

20

65

M32 x 1,5

Magforce STW

31

Top view

Connecting diagrams
230 V AC
L1
N
PE

230 V AC
L1
N
PE

K2
K1

K2

K1

K2

K2

K1

K1
C

M
Z

With optional limit switch

Technical data

Push load
Pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

STW 5007

STW 7010

STW 10020

STW 15040

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

5 000
5 000
12
100 to 700
S+273
230
700
3,3
15 (1,5/8,5)
10 to +40
54
14,6
Silver

7 000
7 000
8
100 to 700
S+273
230
710
3,5
10 (1/9)
10 to +40
54
14,6
Silver

10 000
10 000
4
100 to 700
S+273
230
710
3,5
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
2
100 to 700
S+273
230
750
3,5
10 (1/9)
10 to +40
54
14,6
Silver

Linear actuators AC versions

Magforce STW

Magforce STW

Performance diagram

Ordering key

Safety load factor conditions

Stroke (mm)

Speed (mm/s)
800

14

S TW

S=4

Add. bearing
recommended

700

12

600

Type

10
500

Load:
5 000 N
7 000 N
10 000 N
15 000 N

8
400
6

300

200

100

Standard
guiding

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

0
0

5 000

10 000

15 000

10

16

18

Load (kN)

Load (N)

Speed-load diagram

14

STW 5007-200
STW 7010-200
STW 10020-200
STW 15040-200

05007
07010
10020
15040

Bending of spindle
S = safety factor Euler 3

100
200
300
400
500
600
700

Option 1:
No option
Others*

01
XX

Option 2:
No option
Adapterbolt M18 1031,0106
Fork head (including adapterbolt) 1051,9038

Options

0
E
F

Option 3:
No option
Limit switch
Potentiometer (1 000 )
Encoder 1063,0020

0
1
2
3

Options shown in italics are only available on request.

Stroke + 290

Stroke

18

Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: STW0500710001.
Example for ordering an actuator with option fork head: STW0500710001F0 (F0= with fork head).
* Example for others XX: Back up nut, extended motor shaft, low temperature grease...
22

M32 x 2,5

SW 30

36

SW 27
SW 30

18

36

40

M18 x 2,5

40

17
82

Adapter

25

Spare parts
Stroke

Designation

Order N

ZBE1031,0106
ZBE1051,9038

M/0125265
M/0124705

Stroke + 377
Stroke + 419

Adapter bolt
Fork head

Front attachment

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2310 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce STD

Linear actuators AC versions

Dimensional drawing

116

54

116

56

140
35

Linear actuator

75

20

16 F7

174

95

Retracted length = stroke + 273


Stroke

69

40

PG 16 clamprange 815

67

Rear view

Stroke + 293

Side view
Limit switches or potentiometer on request

20

65

M32 x 1,5

Magforce STD

31

Top view

Connecting diagrams
3x400 V AC
L1
L2
L3
N
PE

K1

K2
K1

K1
K2

7
9

K1
K2

5
6

K2

K1

K1
K2

K2

3x400 V AC
L1
L2
L3
N
PE

7
9

5
6

Limit switch

With optional limit switch

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

STD 10007

STD 12010

STD 15020

STD 15040

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

10 000
10 000
10
100 to 700
S+273
3400
920
1,8
25 (2,5/7,5)
10 to +40
54
14,6
Silver

12 000
12 000
7
100 to 700
S+273
3400
800
1,7
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
4
100 to 700
S+273
3400
700
1,6
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
2
100 to 700
S+273
3400
500
1,4
10 (1/9)
10 to +40
54
14,6
Silver

Linear actuators AC versions

Magforce STD

Magforce STD

Performance diagram

Ordering key

Safety load factor conditions

S T D
Speed (mm/s)

Stroke (mm)

14

800

12

700

F
S=4

Type

Add. bearing
recommended

Load:
10 000 N
12 000 N
15 000 N / 4 mm/s
15 000 N / 2 mm/s

600

10

500
8
400
6

10007
12010
15020
15040

300

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

4
200
2

Standard
guiding

100

0
0

5 000

10 000

15 000

10

Load (N)

Speed-load diagram

12

14

16

Load (kN)

STD 10007-200
STD 12010-200
STD 15020-200
STD 15040-200

Bending of spindle
S = safety factor Euler 3

100
200
300
400
500
600
700

Option 1:
No option
Others*

01
XX

Option 2:
No option
Adapterbolt M18 1031,0106
Fork head (including adapterbolt) 1051,9038

0
E
F

Option 3:
No option
Limit switch
Potentiometer (1 000 )
Encoder 1063,0020

Options

0
1
2
3

Options shown in italics are only available on request.

18

Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: STD1000710001.
Example for ordering an actuator with option fork head: STD1000710001F0 (F0=with fork head).
* Example for others XX: Back up nut, extended motor shaft, low temperature grease, add. guiding bush...
22

17
82

36

SW 27

SW 30

36

18
40

M18 x 2,5

SW 30

Stroke + 290

40

M32 x 1,5

Stroke

25
Stroke

Stroke + 377

Spare parts

Stroke + 419

Adapter

Fork head

Adapter bolt
Fork head

Designation

Order N

ZBE1031,0106
ZBE1051,9038

M/0125265
M/0124705

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2320 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce STG

Linear actuators DC versions

Dimensional drawing

113

113

61

Cable length max. 500 mm

140

75
16 F7

173

69

40

35

Retracted length = stroke + 273

Linear actuator

Stroke

Stroke + 293

Free-wheel-brake on request

95

67

Side view
Rear view
Cable length max. 500 mm

Limit switches or potentiometer on request

Benefits

20

65

M32 x 1,5

Magforce STG

31

Top view

Modular
Robust
Reliable

Connecting diagrams

High speed and/or high load

24 V DC +

24 V DC +

All metal design

K1

K2

K2

K2
Brown

K2
K1

K1

K1

Blue

Brown

Blue

Limit switch

With optional limit switch

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

STG 10007

STG 12010

STG 15020

STG 15040

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

10 000
10 000
14
100 to 700
S+273
24
840
35
10 (1/9)
10 to +40
54
14,6
Silver

12 000
12 000
11
100 to 700
S+273
24
840
35
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
5
100 to 700
S+273
24
768
32
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
3
100 to 700
S+273
24
528
22
10 (1/9)
10 to +40
54
14,6
Silver

Linear actuators DC versions

Magforce STG

Magforce STG
Ordering key

Performance diagram

S T G

Speed (mm/s)

20

Type

18
16

Load:
10 000 N
12 000 N
15 000 N / 5 mm/s
15 000 N / 3 mm/s

14
12
10
8
6
4
2
0
0

5 000

10 000

15 000

10007
12010
15020
15040

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

STG 10007300
STG 12010300
STG 15020300
STG 15040300

Load (N)

100
200
300
400
500
600
700

Speed-load diagram

Option 1:
No option
Others*
Safety load factor conditions

01
XX

Option 2:
No option
Adapterbolt M18 1031,0106
Fork head (including adapterbolt) 1051,9038
Magnetic brake (1,4 Nm) 1031, 0219

Stroke (mm)
800

500

Option 3:
No option
Limit switch
Potentiometer (1 000 )
Encoder 1063,0020

400

Options shown in italics are only available on request.

Add. guiding
recommended

S=4
700
600

0
E
F
G
0
1
2
3

300

Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: STG1000710001.
Example for ordering an actuator with option fork head: STG1000710001F0 (F0= with fork head).
*Example for others XX: Back up nut, extended motor shaft, low temperature grease...

200
Standard
guiding

100
0
0

10

12

14

16

Load (kN)

Bending of spindle S = safety factor Euler 3

Options

Spare parts

Order N

ZBE1031,0106
ZBE1051,9038

M/0125265
M/0124705

18

Designation

Stroke + 290

36

SW 27
SW 30

18

36

M18 x 2,5

SW 30

M32 x 1,5

22
40

Adapter bolt
Fork head

Stroke

Stroke

Stroke + 377
Stroke + 419

17

25

82

SKF is a registered trademark of the SKF Group

Adapter

SKF Group 2012


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

Fork head

PUB L5321,2330 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce SKD

Linear actuators AC versions

Dimensional drawing

130

219

170

114,5

140

16
F7

16

Linear actuator

62

69
40

42

40

65

Limit switch or
potentiometer

Magforce SKD

95

25

174
L = S + 309 2
L = S + 406 2

Side view

Benefits

Rear view

Legend:
S = stroke
L = retracted length

Modular
Robust
Reliable

Connecting diagrams

High speed and/or high load

3x400 V AC
L1
L2
L3
N
PE

All metal design

K1

K2
K1

K1
K2

7
9

K1
K2

5
6

K2

K1

K1
K2

K2

3x400 V AC
L1
L2
L3
N
PE

5
6

Limit switch

With optional limit switch

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

SKD 10007

SKD 12010

SKD 15020

SKD 15040

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

10 000
10 000
25
100 to 700
S+406
3400
920
1,8
25 (2,5/7,25)
10 to +40
54
14,6
Silver

12 000
12 000
18
100 to 700
S+406
3400
800
1,7
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
11
100 to 700
S+406
3400
750
1,6
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
5
100 to 700
S+406
3400
600
1,5
10 (1/9)
10 to +40
54
14,6
Silver

Linear actuators AC versions

Magforce SKD

Magforce SKD
Ordering key

Performance diagram

S K D

Speed (mm/s)
35

Type
30

Load:
10 000 N
12 000 N
15 000 N / 11 mm/s
15 000 N / 5 mm/s

25
20
15

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

10
5
0
0

5 000

10 000

15 000

Load (N)

Speed-load diagram

10007
12010
15020
15040

SKD 10007200
SKD 12010200
SKD 15020200
SKD 15040200

100
200
300
400
500
600
700

Option 1:
No option
Others*

01
XX

Option 2:
No option
Magnetic brake (1,4 Nm) 1031,0219

0
G

Option 3:
No option
Limit switch
Potentiometer (1 000 )
Encoder 1063,0020

0
1
2
3

Options shown in italics are only available on request.


Minimum quantities or additional costs apply for option 1 if shown in italics. For options 2 and 3, please contact your SKF representative.
Example for ordering an actuator without any options: SKD1000710001.
Example for ordering an actuator with option limit switch: SKD100071000101 (01=limit switch).
* Example for others XX: Extended motor shaft,...

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10391 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce SKG

Linear actuators DC versions

Dimensional drawing

110

220

Cable length max. 500 mm

16

Magforce SKG

N75

40

65

40

42

Linear actuator

140

16 F7

35
174

25

95

L=S+309 2
L=S+406 2

Side view

Benefits

Rear view

Legend:
S = stroke
L = retracted length

Modular
Robust
Reliable

Connecting diagrams

High speed and/or high load

24 V DC +

24 V DC +

All metal design

K1

K2

K2

K2
Brown

K2
K1

K1

K1

Blue

Brown

Blue

Limit switch

With optional limit switch

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

SKG 6005

SKG 10010

SKG 13020

SKG 15040

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

6 000
6 000
55
100 to 700
S+406
24
N/A
N/A
10 (1/9)
10 to +40
54
14,6
Silver

10 000
10 000
27
100 to 700
S+406
24
720
30
10 (1/9)
10 to +40
54
14,6
Silver

13 000
13 000
15
100 to 700
S+406
24
672
28
10 (1/9)
10 to +40
54
14,6
Silver

15 000
15 000
8
100 to 700
S+406
24

10 (1/9)
10 to +40
54
14,6
Silver

Linear actuators DC versions

Magforce SKG

Magforce SKG
Ordering key

Performance diagram

S K G

Speed (mm/s)
80

Type
70

Load:
6 000 N
10 000 N
13 000 N
15 000 N

60
50
40

06005
10010
13020
15040

30

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

20
10
0
0

5 000

10 000

15 000

Load (N)

Speed-load diagram

SKG 6005200
SKG 10010200
SKG 13020200
SKG 15040200

100
200
300
400
500
600
700

Option 1:
No option
Others*

01
XX

Option 2:
No option
Magnetic brake (1,4 Nm) 1031, 0219

0
G

Option 3:
No option
Limit switch
Potentiometer (1 000 )
Encoder 1063,0020

0
1
2
3

Options shown in italics are only available on request.


Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.
Example for ordering an actuator without any options: SKG0600510001.
Example for ordering an actuator with option limit switch: SKG060051000101 (01=limit switch).
* Example for others XX: Extended motor shaft,...

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10392 EN April 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce SKS/SKA

Linear actuators AC versions

Connecting diagram

Dimensional drawing

203
145

3x400 V AC
L1
L2
L3
N
PE
F1

K1

K2

K1

25

85

K2

K2

Magforce SKS/SKA

302

S1
down

K1

F2

W1 V1

60

Linear actuator

S2
up

PG 16 clamprange 815

U1
210

+-

AC

25 F8

Retracted length = stroke + 465


Stroke

Stroke + 525

Side view

Benefits
 Modular

30

 High speed and/or high load


61,5

 All metal design

Top view

91

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight (at 200 mm stroke)
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

SKS/SKA 15404

SKS/SKA 20406

SKS/SKA 25412

SKS/SKA 30423

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

15 000
15 000
45
100 to 700
S+465
3400
1 700
3,3
10 (1/9)
10 to +40
54
30
Silver

20 000
20 000
35
100 to 700
S+465
3400
1 650
3,5
10 (1/9)
10 to +40
54
30
Silver

25 000
25 000
17
100 to 700
S+465
3400
1 300
2,8
10 (1/9)
10 to +40
54
30
Silver

30 000
30 000
9
100 to 700
S+465
3400
1 200
3,0
10 (1/9)
10 to +40
54
30
Silver


90

31

85

 Reliable

60

22

175

 Robust

Linear actuators AC versions

Magforce SKS/SKA

Magforce SKS/SKA
Ordering key

Performance diagram

Speed (mm/s)
60

S K S

50

Type

40

Option:
No option

30

Load:
15 000 N
20 000 N
25 000 N
30 000 N

20

10

0
0

5 000

10 000

15 000

20 000

25 000

30 000

Load (N)

Speed-load diagram

15404
20406
25412
30423

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

SKS 15404-300
SKS 20406-300
SKS 25412-300
SKS 30423-300

100
200
300
400
500
600
700

Customer option:
Standard
Others (extended motor shaft, back-up nut, ...)

01
XX

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

S K A

Type
Option:
With limit switches and/or potentiometer

Load:
15 000 N
20 000 N
25 000 N
30 000 N

15404
20406
25412
30423

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

100
200
300
400
500
600
700

Customer option:
Standard with limit switch and potentiometer 1k-ohm
Standard with limit switch
Others (extended motor shaft, back-up nut, ...)

01
02
XX

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2380 EN May 2010

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Magforce SLS

Linear actuators AC versions

Connecting diagram

Dimensional drawing
191

3x400 V AC
L1
L2
L3
N
PE
F1

F2
60

K2
K1

K2

K1

30

30

K1
K2

45

80

S1
down

100

Linear actuator

S2
up

Magforce SLS

Stroke + 364 / +2
W1 V1

U1

Stroke + 446 / +2
+-

AC

Side view
90

62

110

80

Benefits

25

228

 Modular
Top view

 Robust
 Reliable

200

 High speed and/or high load

157

308

381

 All metal design

Rear view

65
238

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
Color

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

SLS 18006

SLS 34013

SLS 50020

SLS 50028

SLS 50050

N
N
mm/s
mm
mm
V AC
W
A
%
C
IP
kg

18 000
18 000
74
100 to 700
S+446
3400
3 000
3,9
10 (1/9)
10 to +40
54
40
Silver

34 000
34 000
36
100 to 700
S+446
3400
3 000
3,9
10 (1/9)
10 to +40
54
40
Silver

50 000
50 000
23
100 to 700
S+446
3400
3 000
3,9
10 (1/9)
10 to +40
54
40
Silver

50 000
50 000
16
100 to 700
S+446
3400
2 200
3,5
10 (1/9)
10 to +40
54
40
Silver

50 000
50 000
9
100 to 700
S+446
3400
1 900
3,6
10 (1/9)
10 to +40
54
40
Silver

Linear actuators AC versions

Magforce SLS

Magforce SLS
Ordering key

Performance diagram

Speed (mm/s)
100

S L S

90
80

Type

70
60

Load:
18 000 N
34 000 N
50 000 N / 23 mm/s
50 000 N / 16 mm/s
50 000 N / 9 mm/s

50
40
30
20

18006
34013
50020
50028
50050

10

Stroke (S):
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm

0
0

10 000

20 000

30 000

40 000

50 000

Load (N)

Speed-load diagram

SLS 18006
SLS 34013
SLS 50020
SLS 50028
SLS 50050

100
200
300
400
500
600
700

Customer option:
Standard
Others (extended motor shaft, ...)

01
XX

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10393 EN May 2010

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CARE 33

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

A^b^i ;ZZY"
hl^iX] WVX`

8dcigdajc^ih

Dual encoder2)

25

CAXC 331)

CAED 5-24R

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

64
50

CARE 33A 24V

Linear actuator

140

CARE 33M 24V


CARE 33H 24V
13

33

STJ

CARE 33

STE

12

=VcYhl^iX]
;ddihl^iX]
9Zh`hl^iX]

L=S+ (150/162/193)*

59

page 394
page 397

L=S+193
M12

2)See

54

26
33

1)See

Benefits

20

22

EHA 3

8,2

33

CAES 31C

* Dimension depends on selected front attachment

38

Connecting diagram
11

 Silent operation

L=S+162

26

6,1

10

 Multiple speed/load variants


 Easy to adjust limit switches

L=S+150

22

13

 Different attachment options

12/24 V DC
+

 Digital encoder feedback


3
3

E 12,7

1
2

1
2

Limit
switch

Limit
switch
1

Legend:
S = stroke
L = retracted length

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
Color

1)
2)

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CARE 33A

CARE 33M

CARE 33H

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

2 000
2 000
8 to 121)
50 to 300
S+150/162/1932)
24
N/A
3,5
15
10 to +50
44/65
1,5 to 2,0
Black

1 400
1 400
16 to 221)
50 to 500
S+150/162/1932)
24
N/A
3,5
20
10 to +50
44/65
1,5 to 2,0
Black

800
800
32 to 451)
50 to 500
S+150/162/1932)
24
N/A
3,5
30
10 to +50
44/65
1,5 to 2,0
Black

Depending on selected motor


Dimension depends on selected front attachment

Rear
attachment
orientation view.

Linear actuators DC versions

CARE 33

CARE 33
Ordering key

Performance diagrams

C A R E 3 3
Type
Speed (mm/s)

Current consumption (A)

50

5,0

45

4,5

40

4,0

35

3,5

30

3,0

25

2,5

20

2,0

15

1,5

10

1,0

Load:
2 000 N
1 400 N
800 N
Stroke (S):
50 mm
100 mm
150 mm
200 mm
300 mm
400 mm (not possible for CARE 33A)
500 mm (not possible for CARE 33A)
Other stroke lengths

0,5

0
0

200

400

600

800

1 000 1 200

1 400

1 600

1 800 2 000

200

400

600

800

1 000 1 200

Load (N)

Speed-load diagram

A
M
H

1 400

1 600

1 800 2 000

Front attachment:
Hole, =12,0 mm
Hole, =12,7 mm
Hole 10 mm, slot 6,1 mm (retracted length, L=S+162 mm)
Male thread M12 (retracted length, L=S+193 mm)

Load (N)

Current-load diagram

A
M
H

050
100
150
200
300
400
500
--1
2
3
4

Rear attachment:
Hole, =12,0 mm
Hole, =12,7 mm
Hole, =8,0 mm
Hole, =10,0 mm

V (mm/s)
V (mm/s)
V (mm/s)
I (A)

1
2
3
4

Type of protection:
IP65
IP44

1
2

Feedback:
No option
Dual encoder

0
1

Cable/Connection plug:
Straight, 2,0 m, no plug
Coiled, 2,0 m, jack plug
Straight, 2,0 m, DIN 8 plug (for 2-channel encoder)
Straight, 2,0 m, jack plug
Straight, 2,5 m, DIN8 plug BCU/VCU (ONLY available for CARE 33A)

1
2
3
5
C5

Orientation of rear attachment:


0
15 clockwise
30 clockwise
45 clockwise
60 clockwise
75 clockwise
90 clockwise
105 clockwise
120 clockwise
130 clockwise
150 clockwise
165 clockwise

000
015
030
045
060
075
090
105
120
130
150
165

Voltage:
24 V DC

24

Self locking feature (mandatory when selecting load version H or M):


No self locking required
Self locking for pull load
Self locking for push load

0
1
2

Options written in italic fonts are only available on demand. Please contact SKF.

SKF is a registered trademark of the SKF Group


SKF Group 2009
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10375 EN November 2009

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CALA 36A

Linear actuators DC versions

A^b^i
hl^iX]

10

33

CAXC 33*

CAED 3-24R

BCU 8

BCU 5

VCU 9

VCU 8

VCU 5

Linear actuator

22

G6

165

10

25
03
0

L=S+215

CALA 36A 12V

CALA 36A 24V


L=S+226

L=S+257

CAES 31C

11

38

G5

6,1

M12

STJ

25,9

G3

EHA3

CALA 36A

STE
=VcYhl^iX]
;ddihl^iX]
9Zh`hl^iX]

10,1

Front attachments

28

* See page 394

Benefits

Connecting diagram

 Compact
 Lubricated for service life
 Corrosion resistant

T2P

12/24 V DC
+

 Selection of front attachments


3

 Limit switches as accessories

Rear attachments
3

1
2

Limit
switch

Limit
switch
1

Legend:
S = stroke
L = retracted length

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight
Color

1)
2)

Electro Mechanical Systems Limited

20
00
30

19
00
30

 High operating reliability

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

52

8dcigda
jc^ih

Dimensional drawing

22

Suitable control units and accessories

Unit

CALA 36A

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

600
600
17 to 311)
50 to 200
S+215/226/2572)
12 or 24
N/A
4,4
2,2
5
0 to +50
44
0,9 to 1,4
Black

Depending on selected motor


Dimension depends on selected front attachment

T2

Linear actuators DC versions

CALA 36A

CALA 36A
Ordering key

Performance diagrams

Current consumption (A)

Speed (mm/s)

C A L A 3 6 A X

X 4

12 V DC
40

30

20

10

Type
Stroke (S):
50 mm
100 mm
150 mm
200 mm
Other stroke lengths

24 V DC

Front attachment:
Male thread, M12
Fork end, =10,1 mm
Hole, =10,0 mm

0
0

200

400

600

800

200

Speed-load diagram

400

600

800

Load (N)

Load (N)

050
100
150
200
--G3
G5
G6

Voltage:
12 V DC
24 V DC

Current-load diagram

D12
D24

Cable:
Straight 0,25 m, no plug
Straight 1,9 m, no plug
Straight 1,9 m, jack plug
Straight, 2,5 m, DIN8 plug (for BCU/VCU)

U
T2
T2P
C5

Options written in italic fonts are only available on demand. Please contact SKF.

SKF is a registered trademark of the SKF Group


SKF Group 2009
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10362 EN November 2009

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAR 22

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

Control Limit
unit switch

53

D12B
M10 1,5

D24B

CAR 22

22

CAES 31C
Hand switch
Foot switch
Desk switch

16

10 e8
66,5

35

49

* See page 379

Benefits

L = S + 205

Connecting diagram

Industrial reliable and robust actuator

89
46

Right and left hand version

3
3

1
2

1
2

Limit
switch

Limit
switch
1

Legend:
S = stroke
L = retracted length

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAR 22

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

1 000 to 1 500
1 000 to 1 500
10 to 30
50 to 300
S+ 205
12 or 24
N/A
9
5
25
20 to +70
44
1,2 to 1,6

60

16,5

23

23

12/24 V DC
+

Electro Mechanical Systems Limited

26

Linear actuator

CAXB 22*

CAED 5-24R

104

Linear actuators DC versions

CAR 22

The Power of Knowledge Engineering


Seals

Performance diagrams

Bearings
and units

Mechatronics

Load (N)

1 500

0
1 400

1 300

1 200

900

1 100

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

Ordering key

800

1 000

12

700

600

12

500

16

400

300

16

1 500

20

1 400

1 300

20

1 200

24

900

1 100

24

1 000

28

800

700

28

600

32

500

400

32

300

10

36

40

200

10

36

100

40

CAR 22.../D12B

Services

I (A)

V (mm/s)

200

I (A)

100

V (mm/s)

Lubrication
systems

Load (N)

CAR 22.../D24B

Dynamic load (N) / Speed (mm/s)

Motor options

1 500/xx
1 500/1510
1 500/1510

No motor
12 V DC, flat motor, IP44
24 V DC, flat motor, IP44

1 000/xx
1 000/3020
1 000/3020

0000
D12B
D24B

C A R

2 2 X

Type
Motor assembly:
Right
Left

Gear 1
Gear 2

R
L

Stroke (S):
50 mm
100 mm
150 mm
200 mm
300 mm
Other stroke lengths

V (mm/s)
I (A)
V (mm/s)
I (A)

050
100
150
200
300
---

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

Duty cycle

Duty factor (%) at 20C


100

80

60

40

SKF is a registered trademark of the SKF Group

20

SKF Group 2010


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

0
0

20

40

60

80

100

Load (N)

PUB MT/P8 1098 EN August 2010


Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAR 32

Linear actuators

Suitable control units and accessories

Dimensional drawing AC version

Control Limit
unit
switch

CAR 32

CAXB 32*

CAEV 110/220

Linear actuator

80

E110C

M12X1,75

CAES 31C

Benefits
Industrial reliable and robust actuator

28

Hand switch
Foot switch
Desk switch

* See page 379

Wide range of components

38

58
71

Right- and left-hand version

L=S+218

Connecting diagram AC version


120/230 V AC
L1
N

55
27,5

23
73

Red

Brown

White

Blue

Red

Legend:
S = stroke
L = retracted length

Black

1Black

Black

27

CW
0
CCW

PE

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight

* Depending on selected motor

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

120 V AC
230 V AC
120 V AC
230 V AC

Unit

CAR 32 AC version

N
N
mm/s
mm
mm
V AC
W
W
A
A
%
C
IP
kg

1 500 to 3 500
1 500 to 3 500
6 to 32*
50 to 700
S + 218
120 or 230
98 (brake 133,2 W)
92 (brake 117,3 W)
0,82 (brake +0,29 A)
0,4 (brake + 0,11 A)
30
20 to +70
20/54
2,1 to 3,7

200

150

E220C
E220CB

159

109

E110CB

Linear actuators

CAR 32

CAR 32

Dimensional drawing DC version

Suitable control units and accessories

Linear actuators

Performance diagrams AC version

Current consumption (A)

Speed (mm/s)
12
1,0

35
3917987

30
25
Control
units

Limit
switch

20

10

CAXB 32*

CAED 9-24R

CAED 5-24R

0,5
15

120
75
300 mm (a)

300 mm (a)

D24CW

58

M12x1,75

D24CS

2 500

3 500

1 500

2 500

3 500

Load (N)

Load (N)

Current-load diagram CAR 32 ... 120 V AC

28

CAES 31C

1 500

Speed-load diagram CAR 32 ... 120 V AC

32

D24CB

100(b)

D24C

74(c)

D12C

20

3917987

Hand switch
Foot switch
Desk switch

L=S+218

Current consumption (A)

Speed (mm/s)

57

38
71

1,0

35

12 e8

* See page 379

30
25

Connecting diagram DC version

20

120 (c)
104

0,5
15

55

12/24 V DC
+

27,5

Limit
switch

73

23

27,5

10

3917987

1 500

2 500

3 500

Speed-load diagram CAR 32 ... 230 V AC

Legend:
S = stroke
L = retracted length
(a) = cable length
(b) = cover for brake (D24CB)
(c) = extended shaft (D24CS)

Limit
switch
2

N
N
mm/s
mm
mm
V DC
W
A
A
A
%
C
IP
kg

1 000 to 3 500
1 000 to 3 500
5 to 60
50 to 700
S+ 218
12 or 24
N/A
13
8
5 (for motor D24CW)
25
20 to +70
20/44
2,1 to 3,7

Gear 1

Gear 4

F (N) Gear

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

3 500

Current-load diagram CAR 32 ... 230 V AC

Duty cycle

CAR 32 DC version

2 500

Gear 2

Technical data

Unit

1 500

Load (N)

Load (N)

3 500

2 500

1 500

2 500

1 500

900

1 500

900

500

6 (E220)/25 F (E110)

4 (E220)/16 F (E110)

3 (E220)/12 (E110)

0
0

10

30

40

50

60

70

80

90

100

Duty factor (%)

CAR 32 ... 230/120 V AC

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

Linear actuators

CAR 32

The Power of Knowledge Engineering


Seals

Performance diagrams DC version

Bearings
and units

Mechatronics
V (mm/s)

V (mm/s)

I (A)
20

60

20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

3 500

V (mm/s)

Services

Ordering key

500

1 000

1 500

2 000

2 500

3 000

3 500

Dynamic load (N) / Speed (mm/s)


3 500/xx
3 500/8
3 500/8
3 500/6
3 500/6
3 500/xx
2 500/1510
3 500/1510
3 500/95
3 500/1510
3 500/1510

CAR 32.../D24C/D24CS/D24CB

I (A)

60

20

54

18

48

16

42

14

36

12

30

10

24

18

12

Motor options

Load (N)

Load (N)

CAR 32.../D12C

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

I (A)

60

Lubrication
systems

2 500/xx
2 500/16
2 500/16
2 500/13
2 500/13
2 500/xx
2 000/3020
2 500/3020
2 500/1810
2 500/3020
2 500/3020

1 500/xx
1 500/32
1 500/32
1 500/26
1 500/26
1 500/xx
1 000/6040
1 500/6040
1 500/3424
1 500/6040
1 500/6040

500

1 000

1 500

2 000

2 500

3 000

0000
E110C
E110CB
E220C
E220CB
0000
D12C
D24C
D24CW
D24CS
D24CB

C A R
0

No motor
120 V AC/60 Hz, 1-phase, IP54
120 V AC/60 Hz, 1-phase, brake, IP20
230 V AC/50 Hz, 1-phase, IP54
230 V AC/50 Hz, 1-phase, brake, IP20
No motor
12 V DC, flat motor, IP44
24 V DC, flat motor, IP44
24 V DC, flat motor, low speed, IP44
24 V DC, flat motor, extended shaft, IP44
24 V DC, flat motor, brake, IP20

3 2 X

3 500

Load (N)

Type

CAR 32.../D24CW
Gear 1
Gear 2
Gear 4

Motor assembly:
Right
Left

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

R
L

Stroke (S):
50 mm
100 mm
200 mm
300 mm
500 mm
700 mm
Other stroke lengths

Duty cycle

050
100
200
300
500
700
---

Option:
Friction clutch
Back-up nut

F
S

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

Duty factor (%) at 20C


100

80

60

40

SKF is a registered trademark of the SKF Group

20

SKF Group 2010


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

0
0

20

40

60

80

100

Load (N)

PUB MT/P8 10973 EN August 2010


Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAR 40

Linear actuators

Suitable control units and accessories

Dimensional drawing AC version

R19

Control Limit
unit switch

Linear actuator

200

40

E220D

40

E220DB

Benefits

CAES 31C
Hand switch
Foot switch
Desk switch

Industrial reliable and robust actuator


Wide range of components

100

53

25
75

* See page 379

Right- and left-hand version

L=S+263

Connecting diagram AC version


120/230 V AC
L1

80
40

Red

Red

Brown

White

Blue

1Black

Legend:
S = stroke
L = retracted length
(b) = cover for brake ( D24CB)

Black

Black

Technical data

Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight

* Depending on selected motor

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

120 V AC
230 V AC
120 V AC
230 V AC

Unit

CAR 40 AC version

N
N
mm/s
mm
mm
V AC
W
W
A
A
%
C
IP
kg

2 000 to 6 000
2 000 to 6 000
9 to 40*
100 to 700
S+263
120 or 230
360
299
3 (brake +0,29 A)
1,3 (brake +0,11 A)
40
20 to +70
20/54
5,8 to 8,4

97

29

CW
0
CCW

40

PE

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption

198 (b)

141

E110D
E110DB

248 (b)

CAR 40

CAXB 40*

CAEV 110/220

119

Linear actuators

CAR 40

Suitable control units and accessories

CAR 40

Dimensional drawing DC version

Linear actuators

Performance diagrams AC version

Speed (mm/s)
R19

Current consumption (A)

35

1,0

30
25
20
0,5
15

150

Limit switch

300 mm (a)

75

10
5

91(c)

76

0
0

121(b)

CAXB 40*

0
300 mm (a)

1 500

2 500

3 500

1 500

2 500

Load (N)

3 500

Load (N)

40

D24D
D24DS
D24DB

25

53

Hand switch
Foot switch
Desk switch

40

M16x2

100

Speed-load diagram CAR 32 ... 120 V AC

16e8

Current-load diagram CAR 32 ... 120 V AC

Speed (mm/s)

75

Current consumption (A)

L=S+263
35

* See page 379

1,0

30
25
143(c)

Connecting diagram DC version

20

127

0,5
80

24 V DC
+

15
40

97

29

40

10
3

0
0

1 500

2 500

3 500

Load (N)

Limit
switch

Limit
switch
1

Current-load diagram CAR 32 ... 230 V AC

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

2 000 to 6 000
2 000 to 6 000
10 to 60
100 to 700
S+263
24
N/A
16
25
20 to +70
20/44
5,8 to 8,4

F (N) Gear

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight

Gear 1

Gear 4

Duty cycle
CAR 40 DC version

3 500

Gear 2

Technical data
Unit

2 500

Load (N)

Speed-load diagram CAR 32 ... 230 V AC

Legend:
S = stroke
L = retracted length
(a) = cable length
(b) = cover for brake (D24CB)
(c) = extended shaft (D24CS)

1 500

3 500

2 500

1 500

2 500

1 500

900

1 500

900

500

6 (E220)/25 F (E110)

4 (E220)/16 F (E110)

3 (E220)/12 (E110)

0
0

10

30

40

50

60

70

80

90

100

Duty factor (%)

CAR 32 ... 230/120 V AC

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

Linear actuators

CAR 40

The Power of Knowledge Engineering


Seals

Performance diagrams DC version

Bearings
and units

Mechatronics

Lubrication
systems

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

Services

Current consumption (A)

Speed (mm/s)
80

20

60

15

40

10

20

Ordering key

0
0

1 000

2 000

3 000

4 000

5 000

6 000

Load (N)

Speed-load diagram CAR 40 ... 24 V DC

1 000

2 000

3 000

4 000

5 000

6 000

Load (N)

Dynamic load (N) / Speed (mm/s)

Current-load diagram CAR 40 ... 24 V DC

6 000/xx
6 000/10
6 000/10
6 000/9
6 000/9
6 000/xx
6 000/15-10
6 000/15-10
6 000/15-10
1

Motor options

4 000/xx
4 000/20
4 000/20
4 000/17
4 000/17
4 000/xx
4 000/30-20
4 000/30-20
4 000/30-20

2 000/xx
2 000/40
2 000/40
2 000/34
2 000/34
2 000/xx
2 000/60-40
2 000/60-40
2 000/60-40

No motor
120 V AC/60 Hz, 1-phase, IP54
120 V AC/60 Hz, 1-phase, brake, IP20
230 V AC/50 Hz, 1-phase, IP54
230 V AC/50 Hz, 1-phase, brake, IP20
No motor
24 V DC, flat motor, IP44
24 V DC, flat motor, extended shaft, IP44
24 V DC, flat motor, brake, IP20

0000
E110D
E110DB
E220D
E220DB
0000
D24D
D24DS
D24DB

C A R

4 0 X

Type
Motor assembly:
Right
Left
Gear 1

V (mm/s)
I (A)

Gear 2

V (mm/s)
I (A)

Gear 4

V (mm/s)
I (A)

R
L

Stroke (S):
100 mm
300 mm
500 mm
700 mm
Other stroke lengths

100
300
500
700
---

Option:
Friction clutch
Back-up nut

Duty cycle

F
S

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

Duty factor (%) at 20C


100

80

60

40

SKF is a registered trademark of the SKF Group

20

SKF Group 2010


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

0
0

20

40

60

80

100

Load (N)

PUB MT/P8 10974 EN August 2010


Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAP 32

Linear actuators

Connecting diagram AC version

Dimensional drawing AC version

120/230 V AC
L1
N
R12

Red

Red

Brown

Blue

White

80

Black

Linear actuator

1Black

Black

CW
0
CCW

PE

M12 1,75

12 e8

28

Benefits
 Easy to install

25

 Robust and reliable

155

20
141

L = S + 301

 Lubricated for service life


 Right- and left-hand version

Green
White
55
27,5

23
73

27

Brown

0
Retract

Green

CW

10K
Extend

White

Brown

Connection diagram for


rotating potentiometer.

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight

* Depending on selected motor

Electro Mechanical Systems Limited

109
159

CAP 32

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

120 V AC
230 V AC
120 V AC
230 V AC

Unit

CAP 32 AC version

N
N
mm/s
mm
mm
V AC
W
W
A
A
%
C
IP
kg

1 500 to 3 500
1 500 to 3 500
6 to 32*
50 to 700
S+301
120 or 230
98 (brake 133,2 W)
92 (brake 117,3 W)
0,82 (brake +0,29 A)
0,4 (brake + 0,11 A)
30
20 to +50
20/54
2,9 to 5,0

Linear actuators

CAP 32

CAP 32

Dimensional drawing DC version

Connecting diagram DC version

Linear actuators

Performance diagrams AC version

12/24 V DC
+
R12
3

Speed (mm/s)

Current consumption (A)

35
3

1,0

30
2
25

Limit
switch

120

Limit
switch

20
0,5

15

M
1 000 mm
58

10
5

M12 1,75
20

12 e8

28

Green
White

0
0

1 500

2 500

3 500

25

Brown
0
Retract

Green

1 500

2 500

Load (N)

3 500

Load (N)

155

CW

White

10K
Extend

141
L = S + 301

Speed-load diagram CAP 32 ... 120 V AC

Brown

Speed (mm/s)

120
300 mm (a)
75

Connection diagram for


rotating potentiometer.

25
58
74 (c)
100 (b)

55

300 mm (a)

D24CS
D24CB

CAED ANR 9-24-PO

CAED ANR 5-24-PO


D24C

73

23

20

20
0,5
15

28

27

27,5

Control units

D12C

1,0

30

1 000 mm

D24CW

Current consumption (A)

35

100

Suitable control units and accessories

Current-load diagram CAP 32 ... 120 V AC

10

3917989

12e8

155

141

0
0

1 500

2 500

3 500

300

Load (N)

Current-load diagram CAP 32 ... 230 V AC

N
N
mm/s
mm
mm
V DC
W
A
A
A
%
C
IP
kg

1 000 to 3 500
1 000 to 3 500
5 to 60*
50 to 700
S+301
12 or 24
N/A
13
8
5 (for motor D24CW)
25
20 to +50
20/44
2,9 to 5,0

F (N) Gear

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
12 V DC
24 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

Gear 1

Gear 4

Duty cycle
CAP 32 DC version

3 500

Gear 2

Technical data
Unit

2 500

Load (N)

Speed-load diagram CAP 32 ... 230 V AC

Legend:
S = stroke
L = retracted length
(a) = cable length
(b) = cover for brake (D24CB)
(c) = extended shaft (D24CS)

1 500

3 500

2 500

1 500

2 500

1 500

900

1 500

900

500

6 (E220)/25 F (E110)

4 (E220)/16 F (E110)

3 (E220)/12 (E110)

0
0

10

30

40

50

60

70

80

90

100

Duty factor (%)

CAP 32 ... 230/120 V AC

* Depending on selected motor

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

Linear actuators

CAP 32

The Power of Knowledge Engineering


Seals

Performance diagrams DC version

Bearings
and units

Mechatronics
V (mm/s)

I (A)

V (mm/s)

20

60

20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

3 500

V (mm/s)

Services

Ordering key

500

1 000

1 500

2 000

2 500

Load (N)

CAP 32.../D12C

3 000

3 500

Dynamic load (N) / Speed (mm/s)

Load (N)

CAP 32.../D24C/D24CS/D24CB

I (A)

60

20

54

18

48

16

42

14

36

12

30

10

24

18

12

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

I (A)

60

Lubrication
systems

Motor options

3 500xx
3 500/8
3 500/8
3 500/6
3 500/6
3 500/xx
2 500/1510
3 500/1510
3 500/95
3 500/1510
3 500/1510

2 500/xx
2 500/16
2 500/16
2 500/13
2 500/13
2 500/xx
2 000/3020
2 500/3020
2 500/1810
2 500/3020
2 500/3020

1 500/xx
1 500/32
1 500/32
1 500/26
1 500/26
1 500/xx
1 000/6040
1 500/6040
1 500/3424
1 500/6040
1 500/6040

C A P
0

500

1 000

1 500

2 000

2 500

3 000

No motor
120 V AC/60 Hz, 1-phase, IP54
120 V AC/60 Hz, 1-phase, brake, IP20
230 V AC/50 Hz, 1-phase, IP54
230 V AC/50 Hz, 1-phase, brake, IP20
No motor
12 V DC, flat motor, IP44
24 V DC, flat motor, IP44
24 V DC, flat motor, low speed, IP44
24 V DC, flat motor, extended shaft, IP44
24 V DC, flat motor, brake, IP20

3 2 X

0000
E110C
E110CB
E220C
E220CB
0000
D12C
D24C
D24CW
D24CS
D24CB

3 500

Load (N)

Type

CAP 32.../D24CW
Gear 1
Gear 2
Gear 4

Motor assembly:
Right
Left

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

R
L

Stroke (S):
50 mm
100 mm
200 mm
300 mm
500 mm
700 mm
Other stroke lengths

Duty cycle

050
100
200
300
500
700
---

Option:
Back-up nut

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

Duty factor (%) at 20C


100

80

60

40

SKF is a registered trademark of the SKF Group

20

SKF Group 2010


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

0
0

20

40

60

80

100

Load (N)

PUB MT/P8 10972 EN August 2010


Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAT 21B

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

Control units

K1 / K2

G1 / G2

BCU 8

BCU 5

VCU 9

VCU 5

VCU 8

25

Linear actuator

12,5

CAT 21B

CAT 21B

12

EHA3
33

STJ
STE
Hand switch
Foot switch
Desk switch

Benefits

45

High o

+
24 V DC

Low en

75,5
28,5

L=S+100

Lubric
Corros
Silent

Red

Black

Range
M

Legend:
S = stroke
L = retracted length

Actuator

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
Color

Electro Mechanical Systems Limited

16

22
17

Ball sc

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAT 21B

N
N
mm/s
mm
mm
V DC
W
A
%
C
IP
kg

600
600
8,1 to 9,7
50 to 300
S+100
24
N/A
0,7
see diagram on next page
N/A
4
0,7 to 1,5
Black

9,5

88

Connecting diagram

Compact design (efficient and cost effective)

Linear actuators DC versions

CAT 21B

CAT 21B
Ordering key

Performance diagrams

Speed (mm/s)

Current consumption (A)

9,8

0,9

9,6

0,8

9,4

C A T

2 1 BX

X 1

Z /

0,7

9,2

Type

0,6

9,0

Motor assembly:
Right
Left

0,5
8,8
0,4
8,6

R
L

0,3

8,4

Stroke (S):
50 mm
100 mm
200 mm
250 mm
300 mm
Other stroke lengths

0,2

8,2
8,0

0,1

7,8

0
0

100

200

300

400

500

600

700

100

200

300

Load (N)

Speed-load diagram

400

500

600

700

Load (N)

050
100
200
250
300
---

Current-load diagram

Rear attachment:
Single ear, hole diameter 6,35 mm
Single ear, hole diameter 8 mm

K1
K2

Front attachment:
Hole diameter 6,35 mm
Hole diameter 8 mm

G1
G2

Motor option:
24 V DC

G24C

Cable option for motors:


Straight cable 610 mm, without plug
Straight cable 2500 mm, DIN8 plug

06
C5

Options written in italic fonts are only available on demand. Please contact SKF.

Options

Duty factor diagram

Standard options

Customer options (available on request)

Right or left handed motor orientation.


With or without motor cover.

Encoder and feedback options


Adjustable or fixed position limit switches
Special front and rear attachments
Special colors and gear house engravings
Special wiring and connectors
Special lead screws and nut combinations
12 V DC motor in quantity of 100 pcs. or greater

Duty factor (%)


50

40

30

If in any application there is a risk that the actuator mechanically runs into the end stop, we recommend that you use the limit switch option.
20

SKF is a registered trademark of the SKF Group

10

100

200

300

400

500

SKF Group 2009


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

600

Load (N)

Printed in Sweden on environmentally friendly paper.


PUB MT/P8 10432 EN Decemmber 2009

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAT 33H

Linear actuators
Dimensional drawing AC version

Suitable control units and accessories

See drawings of front and rear attachments


and motor options on page 276.

Cover for brake

154
104

82
108

CAT 33H

E21)

CAEV 110/220

80

201

Linear actuator

50

Control unit Encoder

E110C

29

E220C

57

33

E110CB
E220CB
L=S+ (167/175/206)*

E380C
CAES 31C

Benefits
Compact


4FFQBHF

Connecting diagrams AC version

Lubricated for service life

120/230 V AC
L1

400 V AC
L1
L2
L3
N
PE
Q1

High speed

CW
0
CCW

PE

Digital encoder feedback

Q2

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
1) Depending
2) Dimension

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

120 V AC
230 V AC
400 V AC
120 V AC
230 V AC
400 V AC

Red

Red

Brown

White

Blue

Q1

Q1

W1 V1
Limit
switch

CAT 33H AC version

N
N
mm/s
mm
mm
V AC
W
W
W
A
A
A
%
C
IP
kg

500 to 1 200
500 to 1 200
20 to 901)
100 to 400
S+150/158/1892)
120, 230 or 400
98 (brake 133,2W)
92 (brake 117,3W)
80
0,82 (brake +0,29A)
0,4 (brake +0,11A)
0,2
30
20 to +50
20/54/55
2 to 2,7

U1

M
3

Unit

on selected motor
depends on selected front attachment

Q2

Limit
switch

Black

1Black

Black

Q2

Technical data

24

120 or 230 V AC
motor

* Dimension depends on selected front attachment

Robust
Modular

23
73

Legend:
S = stroke
L = retracted length

Hand switch
Foot switch
Desk switch

400 V AC
motor

Linear actuators

CAT 33H

Suitable control units and accessories

CAT 33H

Linear actuators

Performance diagrams AC version

Dimensional drawing DC version

88

Speed (mm/s)

Speed (mm/s)

Speed (mm/s)

125

125

125

100

100

100

75

75

75

50

50

50

25

25

25

124

CAED 9-24R

E21)

CAED 5-24R

Control Encoder
units

D12C

55

33

C12C

29

C24C

C24CW
23

D24CB

500

1 000

1 500

0
0

500

1 000

Load (N)

24

1 500

500

1 000

1 500

Load (N)

Load (N)

73

* Dimension depends on selected front attachment

D24CS

0
0

L=S+ (150/158/189)*

D24C

Speed-load diagram CAT 33H ... 120 V AC

Speed-load diagram CAT 33H ... 230 V AC

Speed-load diagram CAT 33H ... 400 V AC

D24CW
CAES 31C

75

Current consumption (A)

Current consumption (A)

1,0

1,0

1,0

0,5

0,5

0,5

300 mm (a)

page 380

300 mm (a)
57

12/24 V DC
+

3
3

73(c)

Connecting diagram DC version

98(b)

1) See

Current consumption (A)

120

Hand switch
Foot switch
Desk switch

0
0

500

1 000

1 500

0
0

500

Load (N)

1 000

1 500

500

1 000

1 500

Load (N)

Load (N)

3917990

Current-load diagram CAT 33H ... 120 V AC


Limit
switch

Legend:
S = stroke
L = retracted length
(a) = cable length
(b) = cover for brake (D24CB)
(c) = extended shaft (D24CS)

Limit
switch
1

Current-load diagram CAT 33H ... 230 V AC

Gear 1

See drawings of front and rear attachments


and motor options on page 276.

Gear 4

Duty cycle
Unit

CAT 33H DC version

N
N
mm/s
mm
mm
V DC
W
A
A
A
%
C
IP
kg

400 to 1 200
400 to 1 200
17 to 1931)
100 to 400
S+150/158/1892)
12 or 24
N/A
18
9
5 (for motors C24CW and D24CW)
20
20 to +50
20/44/65
2 to 2,7

F (N) Gear
1
1 200

F (N) Gear
2

900

25 F (E110)

500

1 200

900

500

600

500

350

500

300

250

6 F (E220)

4 F (E220)

3 F (E220)

0
0

10

30

40

50

60

70

80

90

100

10

30

40

50

Duty factor (%)


1) Depending
2) Dimension

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

Gear 2

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
12 V DC
24 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

Current-load diagram CAT 33H ... 400 V AC

D12C, D24C, D24CB, D24CS, D24CW

on selected motor
depends on selected front attachment

CAT 33H ... 120 V AC

60

70

80

90

100

Duty factor (%)

CAT 33H ... 230 V AC

Linear actuators

CAT 33H

The Power of Knowledge Engineering


Seals

Performance diagrams DC version

Bearings
and units

Mechatronics
V (mm/s)

I (A)

V (mm/s)

20

200

20

180

18

180

18

160

16

160

16

140

14

140

14

120

12

120

12

100

10

100

10

80

80

60

60

40

40

20

20

500

1 000

1 500

2 000

2 500

Dynamic load (N) / Speed (mm/s)

3 000

500

1 000

1 500

2 000

2 500

CAT 33H.../D12C

I (A)

V (mm/s)

I (A)

200

20

200

20

180

18

180

18

160

16

160

16

140

14

140

14

120

12

120

12

100

10

100

10

80

80

60

60

40

40

20

20

500

1 000

1 500

2 000

2 500

3 000

500

1 000

1 500

2 000

2 500

I (A)

Load (N)

V (mm/s)
20

180

18

180

18

160

16

160

16

140

14

140

14

120

12

120

12

100

10

100

10

80

80

60

60

40

40

20

20

500

1 000

1 500

2 000

2 500

3 000

3 3 HX

No motor
120 V AC/60 Hz, 1-phase, IP54
120 V AC/60 Hz, 1-phase, brake, IP20
230 V AC/50 Hz, 1-phase, IP54
230 V AC/50 Hz, 1-phase, brake, IP20
400 V AC/50 Hz, 3-phase, IP55
No motor
12 V DC, IP44 (65)
12 V DC, flat motor, IP44
24 V DC, IP44 (65)
24 V DC, low speed, IP44 (65)
24 V DC, flat motor, IP44
24 V DC, flat motor, brake, IP20
24 V DC, flat motor, ext. shaft, IP44
24 V DC, flat motor, low speed, IP44

0000
E110C
E110CB
E220C
E220CB
E380C
0000
C12C
D12C
C24C
C24CW
D24C
D24CB
D24CS
D24CW

R
L
100
200
300
400
---

Rear attachment (see page 276):


Fork ear, =12,0 mm
Fork ear, =12,7 mm
Single ear, =12,0 mm
Single ear, =12,7 mm

A1
A2
K1
K2

Front attachment (see page 276):


Hole, =12,0 mm
Hole, =12,7 mm
Male thread, M12
Female thread, M12
Fork ear, =10,1 mm
0

500

1 000

Load (N)

CAT 33H.../C24CW

600/xx
500/90
500/90
500/90
500/90
500/90
600/xx
400/174150
400/170100
500/174140
500/10069
500/193140
500/193140
500/193140
500/10065

Stroke (S):
100 mm
200 mm
300 mm
400 mm
Other stroke lengths

I (A)

200

Motor assembly:
Right
Left

3 000

CAT 33H.../D24C/D24CB/D24CS

20

900/xx
900/37
900/37
900/37
900/37
900/37
900/xx
600/10080
600/9565
900/11379
800/6035
900/9566
900/9566
900/9566
800/6335

Type

Load (N)

200

Motor options

1 200/xx
1 200/20
1 200/20
1 200/20
1 200/20
1 200/20
1 200/xx
1 000/5038
1 000/4725
1 200/5636
1 200/2717
1 200/4837
1 200/4837
1 200/4837
1 200/3017

C A T

CAT 33H.../C24C
V (mm/s)

3 000

Load (N)

CAT 33H.../C12C

Services

Ordering key

Load (N)

V (mm/s)

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

I (A)

200

Lubrication
systems

1 500

2 000

2 500

G1
G2
G3
G4
G5

3 000

Load (N)

Feedback:
No encoder (no code)
Encoder (for all standard motors)

CAT 33H.../D24CW

E2

Option:
Friction clutch (not available with option encoder)
No friction clutch

F
Z

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Gear 1
Gear 2
Gear 4

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10986 EN August 2010
Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAT 33

Linear actuators

Suitable control units and accessories

Dimensional drawing AC version

See drawings of front and rear attachments


and motor options on page 276.

Cover for brake

Control Limit Encoder


unit switch

50

201

108

E22)

CAXC 331)

CAEV 110/220

CAT 33

82

80

Linear actuator

154
104

E110C
E110CB

29

57

33

E220C
E220CB
E380C

L=S+ (167/175/206)*

23
73

CAES 31C
Hand switch
Foot switch
Desk switch

Benefits
Small

Legend:
S = stroke
L = retracted length

24

120 or 230 V AC
motor

1)See

page 378
2)See page 380

* Dimension depends on selected front attachment

Robust
Highly efficient

Connecting diagrams AC version


120/230 V AC
L1

Lubricated for service life

Digital encoder feedback

CW
0
CCW

PE

400 V AC
L1
L2
L3
N
PE
Q1

Q2

Q2

Q1

Red

Red

Brown

White

Blue

1Black

W1 V1
Limit
switch

Black

Black

Q2

Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
1) Depending
2) Dimension

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

120 V AC
230 V AC
400 V AC
120 V AC
230 V AC
400 V AC

Unit

CAT 33 AC version

N
N
mm/s
mm
mm
V AC
W
W
W
A
A
A
%
C
IP
kg

800 to 3 000
800 to 3 000
5 to 241)
100 to 400
S+150/158/1892)
120, 230 or 400
98 (brake 133,2W)
92 (brake 117,3W)
80
0,82 (brake +0,29A)
0,4 (brake + 0,11A)
0,2
30
20 to +50
20/54/55
2 to 2,7

on selected motor
depends on selected front attachment

Limit
switch

U1

M
3

Technical data

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption

Q1

400 V AC
motor

Linear actuators

CAT 33

Suitable control units and accessories

CAT 33

Linear actuators

Performance diagrams AC version

Dimensional drawing DC version

88

Speed (mm/s)

Speed (mm/s)

Speed (mm/s)

25

25

25

20

20

20

15

15

15

10

10

10

Encoder Limit
switch

CAXC2)

CAED 9-24R

E21)

CAED 5-24R

124

Control
units

29

D12C

55

33

C12C
C24C

C24CW

L=S+ (150/158/189)*

D24C

23

D24CB

73

1 000

2 000

3 000

0
0

1 000

2 000

Load (N)

* Dimension depends on selected front attachment

D24CS

0
0

24

3 000

1 000

2 000

3 000

Load (N)

Speed-load diagram CAT 33 ... 120 V AC

Load (N)

Speed-load diagram CAT 33 ... 230 V AC

Speed-load diagram CAT 33 ... 400 V AC

D24CW
CAES 31C

Current consumption (A)


120

Hand switch
Foot switch
Desk switch

Current consumption (A)

Current consumption (A)

1,0

1,0

1,0

0,5

0,5

0,5

75
300 mm (a)

1)
2)

See page 380


See page 378

57
3

98(b)

300 mm (a)

12/24 V DC
+

73(c)

Connecting diagram DC version

0
0

1 000

2 000

3 000

1
2

1 000

2 000

3 000

1 000

2 000

Load (N)

3917990

Legend:
S = stroke
L = retracted length
(a) = cable length
(b) = cover for brake (D24CB)
(c) = extended shaft (D24CS)

Limit
switch
1

Current-load diagram CAT 33 ... 230 V AC

Gear 1

See drawings of front and rear attachments


and motor options on page 276.

Gear 4

Duty cycle
Unit

CAT 33 DC version

N
N
mm/s
mm
mm
V DC
W
A
A
A
%
C
IP
kg

800 to 3 000
800 to 3 000
5 to 521)
100 to 400
S+150/158/1892)
12 or 24
N/A
18
9
5 (for motors C24CW and D24CW)
15
20 to +50
20/44/65
2 to 2,7

F (N) Gear
2

2 400

1 600

800

1 600

1 050

500

800

500

300

25 F (E110)

3 000

2 000

1 000

2 000

1 500

650

1 000

650

350

6 F (E220)

4 F (E220)

16 F (E110)

12 F (E110)

3 F (E220)

0
0

10

30

40

50

60

70

80

90

100

10

30

40

50

Duty factor (%)


2) Dimension

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

Gear 2

F (N) Gear

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
12 V DC
24 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

Current-load diagram CAT 33 ... 400 V AC

D12C, D24C, D24CB, D24CS, D24CW

Technical data

1) Depending

3 000

Load (N)

Current-load diagram CAT 33 ... 120 V AC


Limit
switch

0
0

Load (N)

on selected motor
depends on selected front attachment

CAT 33 ... 120 V AC

60

70

80

90

100

Duty factor (%)

CAT 33 ... 230 V AC

Linear actuators

CAT 33

The Power of Knowledge Engineering


Seals

Performance diagrams DC version

Bearings
and units

Mechatronics
V (mm/s)

I (A)

V (mm/s)

20

60

20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

Dynamic load (N) / Speed (mm/s)

500

1 000

1 500

2 000

2 500

CAT 33.../D12C

I (A)

V (mm/s)

I (A)

60

20

60

20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

500

1 000

1 500

2 000

2 500

I (A)

Load (N)

V (mm/s)
20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

3 3 X

No motor
120 V AC/60 Hz, 1-phase, IP54
120 V AC/60 Hz, 1-phase, brake, IP20
230 V AC/50 Hz, 1-phase, IP54
230 V AC/50 Hz, 1-phase, brake, IP20
400 V AC/50 Hz, 3-phase, IP55
No motor
12 V DC, IP44 (65)
12 V DC, flat motor, IP44
24 V DC, IP44 (65)
24 V DC, low speed, IP44 (65)
24 V DC, flat motor, IP44
24 V DC, flat motor, brake, IP20
24 V DC, flat motor, IP44, ext. shaft
24 V DC, flat motor, low speed, IP44

0000
E110C
E110CB
E220C
E220CB
E380C
0000
C12C
D12C
C24C
C24CW
D24C
D24CB
D24CS
D24CW

R
L
100
200
300
400
---

Rear attachment (see page 276):


Fork ear, =12,0 mm
Fork ear, =12,7 mm
Single ear, =12,0 mm
Single ear, =12,7 mm

A1
A2
K1
K2

Front attachment (see page 276):


Hole, =12,0 mm
Hole, =12,7 mm
Male thread, M12
Female thread, M12
Fork ear, =10,1 mm
0

500

1 000

Load (N)

CAT 33.../C24CW

Stroke (S):
100 mm
200 mm
300 mm
400 mm
Other stroke lengths

I (A)

60

1 000/xx
800/24
800/24
1 000/20
1 000/20
1 000/20
1 000/xx
1 000/4838
800/3921
1 000/5240
1 000/2518
1 000/4335
1 000/4335
1 000/4335
1 000/2619

Motor assembly:
Right
Left

3 000

CAT 33.../D24C/D24CB/D24CS

20

2 000/xx
1 600/12
1 600/12
2 000/10
2 000/10
2 000/10
2 000/xx
2 000/2420
1 600/2115
2 000/2620
2 000/139
2 000/2518
2 000/2518
2 000/2518
2 000/138

C A T

Load (N)

60

Motor options

3 000/xx
2 400/6
2 400/6
3 000/5
3 000/5
3 000/5
3 000/xx
3 000/1310
2 400/117
3 000/1310
3 000/75
3 000/129
3 000/129
3 000/129
3 000/75

Type

CAT 33.../C24C
V (mm/s)

3 000

Load (N)

CAT 33.../C12C

Services

Ordering key

Load (N)

V (mm/s)

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

I (A)

60

Lubrication
systems

1 500

2 000

2 500

G1
G2
G3
G4
G5

3 000

Feedback:
No encoder (no code)
Encoder (for all standard motors)

Load (N)

CAT 33.../D24CW

E2

Option:
Friction clutch (not available with option encoder)
No friction clutch

F
Z

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Gear 1
Gear 2
Gear 4

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10975 EN August 2010
Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAT 32B

Linear actuators
Dimensional drawing AC version

Suitable control units and accessories

See drawings of front and rear attachments


and motor options on page 276.

154

Control Limit Encoder


unit switch

104

50

82
108

E22)

CAT 32B

CAXB 32B1)

CAEV 110/220

80

201

Linear actuator

Cover for brake

E110C
E110CB
57

E220C
E220CB
E380C

23
73

L= S+ (167/175/206)*

CAES 31C

Benefits

Hand switch
Foot switch
Desk switch

Compact

Legend:
S = stroke
L = retracted length

* Dimension depends on selected front attachment

Robust
Modular

Connecting diagrams AC version


120/230 V AC
L1

Lubricated for service life

400 V AC
L1
L2
L3
N
PE
Q1

High efficiency

CW
0
CCW

PE

Digital encoder feedback

Q2

Rated push load


Rated pull load
Speed (at full load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption
Duty cycle
Ambient temperature
Type of protection
Weight
1) Depending
2) Dimension

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

120 V AC
230 V AC
400 V AC
120 V AC
230 V AC
400 V AC

Red

Red

Brown

White

Blue

Q1

Q1

W1 V1
Limit
switch

CAT 32B AC version

N
N
mm/s
mm
mm
V AC
W
W
W
A
A
A
%
C
IP
kg

1 500 to 3 500
1 500 to 3 500
6,5 to 321)
50 to 700
S+167/175/2062)
120, 230 or 400
98 (brake 133,2 W)
92 (brake 117,3 W)
80
0,82 (brake +0,29 A)
0,4 (brake +0,11 A)
0,2
30
20 to +50
20/54/55
2 to 3,5

U1

M
3

Unit

on selected motor
depends on selected front attachment

Q2

Limit
switch

Black

1Black

Black

Q2

Technical data

Electro Mechanical Systems Limited

120 or 230 V AC
motor

1)See

page 379
2)See page 380

24

400 V AC
motor

Linear actuators

CAT 32B

Suitable control units and accessories

CAT 32B

Linear actuators

Performance diagrams AC version

Dimensional drawing DC version

88

Speed (mm/s)

124
55

E22)

CAXB 32B1)

CAED 9-24R

CAED 5-24R

Speed (mm/s)

Speed (mm/s)

35

35

35

30

30

30

25

25

25

20

20

20

15

15

15

10

10

10

Limit
switch Encoder

32

Control
units

29

C12C
D12C
C24C
C24CW

23

L=S+(167/175/206)*

24

73

D24C

1 500

2 500

3 500

0
0

1 500

2 500

Load (N)

3 500

1 500

2 500

Load (N)

3 500

Load (N)

D24CB
D24CS

120

D24CW

75

Speed-load diagram CAT 32B ... 120 V AC

Speed-load diagram CAT 32B ... 230 V AC

Speed-load diagram CAT 32B ... 400 V AC

300 mm (a)

CAES 31C

Current consumption (A)

Hand switch
Foot switch
Desk switch

Current consumption (A)

1,0

1,0

0,5

0,5

0,5

page 379
page 380

57

300 mm (a)

98(b)

2) See

73(c)

1) See

Current consumption (A)

1,0

Connecting diagram DC version


12/24 V DC
+
3917990

3
3

Limit
switch
1

0
0

Legend:
S = stroke
L = retracted length
(a) = cable length
(b) = cover for brake (D24CB)
(c) = extended shaft (D24CS)

Limit
switch

1 500

2 500

3 500

0
0

1 500

Load (N)

D12C, D24C, D24CB, D24CS, D24CW

Current-load diagram CAT 32B ... 120 V AC

Current-load diagram CAT 32B ... 230 V AC

1 000 to 4 000
1 000 to 4 000
5 to 521)
50 to 700
S+167/175/2062)
12 or 24
N/A
18
9
5 (for motors C24CW and D24CW)
20
20 to +50
20/44/65
2 to 3,5

F (N) Gear
1

3 500

2 500

1 500

2 500

1 500

900

1 500

900

500

6 (E220)/25 F (E110)

4 (E220)/16 F (E110)

3 (E220)/12 (E110)

0
0

10

30

40

50

60

70

80

90

100

Duty factor (%)


1) Depending
2) Dimension

2 500

on selected motor
depends on selected front attachment

CAT 32B ... 230/120 V AC

3 500

Load (N)

Current-load diagram CAT 32B ... 400 V AC

Gear 4

Duty cycle

N
N
mm/s
mm
mm
V DC
W
A
A
A
%
C
IP
kg

1 500

Gear 2

Technical data

Rated push load


Rated pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

Gear 1

See drawings of front and rear attachments


and motor options on page 276.

* Dimension depends on selected front attachment

CAT 32B DC version

3 500

Load (N)

Unit

2 500

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

Linear actuators
Performance diagrams DC version

V (mm/s)

Ordering key

I (A)

V (mm/s)

I (A)

80

20

80

20

72

18

72

18

64

16

64

16

56

14

56

14

48

12

48

12

40

10

40

10

32

32

24

24

16

16

500

1 000 1 500 2 000 2 500 3 000 3 500 4 000

Dynamic load (N) / Speed (mm/s)

500

1 000 1 500 2 000 2 500 3 000 3 500 4 000

Load (N)

Load (N)

I (A)

V (mm/s)

I (A)

80

20

80

20

72

18

72

18

64

16

64

16

56

14

56

14

48

12

48

12

40

10

40

10

32

32

24

24

16

16

500

1 000 1 500 2 000 2 500 3 000 3 500 4 000

V (mm/s)

I (A)

500

1 000 1 500 2 000 2 500 3 000 3 500 4 000

20

72

18

72

18

64

16

64

16

56

14

56

14

48

12

48

12

40

10

40

10

32

32

24

24

16

16

1 000 1 500 2 000 2 500 3 000 3 500 4 000

No motor
120 V AC/60 Hz, 1-phase, IP54
120 V AC/60 Hz, 1-phase, brake, IP20
230 V AC/50 Hz, 1-phase, IP54
230 V AC/50 Hz, 1-phase, brake, IP20
400 V AC/50 Hz, 3-phase, IP55
No motor
12 V DC, IP44 (65)
12 V DC, flat motor, IP44
24 V DC, IP44 (65)
24 V DC, low speed motor, IP44 (IP65)
24 V DC, flat motor, IP44
24 V DC, flat motor, brake, IP20
24 V DC, flat motor, ext.shaft, IP44
24 V DC, flat motor, low speed, IP44

0000
E110C
E110CB
E220C
E220CB
E380C
0000
C12C
D12C
C24C
C24CW
D24C
D24CB
D24CS
D24CW

R
L
050
100
200
300
400
500
700
---

Rear attachment (see page 276):


Fork ear, =12,0 mm
Fork ear, =12,7 mm
Single ear, =12,0 mm
Single ear, =12,7 mm

I (A)

80

3 2 BX

Stroke (S):
50 mm
100 mm
200 mm
300 mm
400 mm
500 mm
700 mm
Other stroke lengths

Load (N)

V (mm/s)

A1
A2
K1
K2

Front attachment (see page 276):


Hole, =12,0 mm
Hole, =12,7 mm
Male thread, M12
Female thread, M12
Fork ear, =10,1 mm

500

G1
G2
G3
G4
G5

Feedback:
No encoder (no code)
Encoder (for all standard motors)

1 000 1 500 2 000 2 500 3 000 3 500 4 000

Load (N)

CAT 32B.../C24CW

Motor assembly:
Right
Left

CAT 32B.../D24C/D24CB/D24CS

20

500

1 500/xx
1 500/32
1 500/32
1 500/26
1 500/26
1 500/28
1 500/xx
1 500/6348
1 000/6743
1 500/6552
1 500/3124
1 500/6544
1 500/6544
1 500/6544
1 500/3920

Type

80

2 500/xx
2 500/16
2 500/16
2 500/13
2 500/13
2 500/14
2 500/xx
2 500/3225
2 000/3419
2 500/3326
2 500/1710
2 500/3322
2 500/3322
2 500/3322
2 500/2010

C A T

Load (N)

CAT 32B.../C24C

Motor options

4 000/xx
3 500/8
3 500/8
3 500/6,5
3 500/6,5
3 500/7
4 000/xx
4 000/1712
3 000/1711
4 000/1713
4 000/95
4 000/1612
4 000/1612
4 000/1612
4 000/105

CAT 32B.../D12C

CAT 32B.../C12C
V (mm/s)

CAT 32B

CAT 32B

E2

Load (N)

Option:
Friction clutch (not available with option encoder)
No friction clutch
Back-up nut

CAT 32B.../D24CW

F
Z
S

Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.

Gear 1
Gear 2
Gear 4

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10985 EN August 2010
Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAP 43A

Linear actuators DC versions

Suitable control units and accessories

Dimensional drawing

CAED ANR 9-24-PO

CAED ANR 5-24-PO

8dcigdajc^ih

C24C

Linear actuator

29

D24C

56

43

C24CW
D24CW
57

CAP 43A

(a) 2m

23

26

L = S + 150/158/189*

Connecting diagram
24 V DC
+
88

Benefits

300 mm (a)

124

 Robust and reliable

120

57

 Long lifetime
 Wide range of components

Limit
switch

Limit
switch
1

 Right- and left-hand version

3917988

C24C, C24CW

 Analogical feedback

0
Retract

Black

CW

10K
Extend

Brown

Red

Legend:
S = stroke
L = retracted length
(a) = cable length
See drawings of front and rear attachments on page 286.

Connection diagram for


linear potentiometer.

* Dimension depends on selected front attachment

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 24 V DC
24 V DCW
Duty cycle
Ambient temperature
Type of protection
Weight

1)Depending
2)Dimension

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAP 43A

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

1 000 to 3 000
1 000 to 3 000
5 to 521)
100 to 400
S+150/158/1892)
24
N/A
9
5
15
20 to +50
44
2,0 to 2,7

on selected motor
depends on selected front attachment

D24C, D24CW

Linear actuators DC versions

Ordering key

Performance diagrams

V (mm/s)

I (A)

V (mm/s)

I (A)

60

20

60

20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

Dynamic load (N) / Speed (mm/s)

500

1 000

1 500

2 000

2 500

Load (N)

I (A)

V (mm/s)

60

20

60

20

54

18

54

18

48

16

48

16

42

14

42

14

36

12

36

12

30

10

30

10

24

24

18

18

12

12

500

1 000

1 500

2 000

2 500

3 000

CAP 43A.../D24C

Type

I (A)

Motor assembly:
Right
Left

1 000/xx
1 000/5240
1 000/2518
1 000/4335
1 000/2619

Stroke (S):
100 mm
200 mm
300 mm
400 mm

4 3 A X

No motor
24 VDC, IP44
24 VDC, IP44
24 VDC, flat motor, IP44
24 VDC, flat motor, low speed, IP44

0000
C24C
C24CW
D24C
D24CW

R
L
100
200
300
400

Rear attachment (see page 286):


Fork ear, =12,0 mm
Fork ear, =12,7 mm
Single ear, =12,0 mm
Single ear, =12,7 mm
0

500

1 000

Load (N)

CAP 43A.../C24CW

2 000/xx
2 000/2620
2 000/139
2 000/2518
2 000/138

C A P

3 000

Motor options

3 000/xx
3 000/1310
3 000/75
3 000/129
3 000/75

Load (N)

CAP 43A.../C24C
V (mm/s)

CAP 43A

CAP 43A

1 500

2 000

2 500

A1
A2
K1
K2

3 000

Front attachment (see page 286):


Hole, =12,0 mm
Hole, =12,7 mm
Male thread, M12
Female thread, M12
Fork ear, =10,1 mm

Load (N)

CAP 43A.../D24CW
Gear 1
Gear 2
Gear 4

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

G1
G2
G3
G4
G5

Option:
Friction clutch

Cable option for C24C(W) motors:


No cable
Straight, 2,0 m
Duty cycle

U
T2

EMC filter

Motor without cover

Duty factor (%) at 20C


100

80

60

40

SKF is a registered trademark of the SKF Group

20

SKF Group 2009


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

0
0

20

40

60

80

100

Load (N)

Printed in Sweden on environmentally friendly paper.


PUB MT/P8 10447 EN December 2009

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAP 43B

Linear actuators DC versions


Dimensional drawing

CAED ANR 9-24-PO

CAED ANR 5-24-PO

Suitable control units and accessories

C24C
C24CW

Linear actuator

D24C

29

56

43

D24CW

CAP 43B

57

23

(a) 2m

L = S + 167/175/206*

Connecting diagram

24 V DC
+

Benefits

 Robust and reliable

88

120

1
2

300 mm (a)

57

124

 Long lifetime
 Wide range of components
 Right- and left- version

3917988

 Analogical feedback

D24C/D24CW
0
Retract

Black

CW

10K
Extend

Brown

Red

Legend:
S = stroke
L = retracted length
(a) = cable length
(c) = extended shaft (D24CS)
See drawings of front and rear attachments on page 286.

Connection diagram for


linear potentiometer.

* Dimension depends on selected front attachment

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 24 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight

1)Depending
2)Dimension

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAP 43B

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

1 500 to 4 000
1 500 to 4 000
5 to 651)
50 to 700
S+167/175/2062)
24
N/A
9
5 (for motors C24CW and D24CW)
20
20 to +50
44
2,0 to 2,7

on selected motor
depends on selected front attachment

C24C/C24CW

26

Linear actuators DC versions

Ordering key

Performance diagrams

V (mm/s)

I (A)

V (mm/s)

I (A)

80

20

80

20

72

18

72

18

64

16

64

16

56

14

56

14

48

12

48

12

40

10

40

10

32

32

24

24

16

16

500

1 000 1 500 2 000 2 500 3 000 3 500 4 000

Dynamic load (N) / Speed (mm/s)

500

V (mm/s)

80

20

80

20

72

18

72

18

64

16

64

16

56

14

56

14

48

12

48

12

40

10

40

10

32

32

24

24

16

16

500

1 000 1 500 2 000 2 500 3 000 3 500 4 000

CAP 43B.../D24C

Type

I (A)

Motor assembly:
Right
Left

1 500/xx
1 500/65-52
1 500/31-24
1 500/65-44
1 500/39-20

Stroke (S):
50 mm
100 mm
200 mm
300 mm
400 mm
500 mm
700 mm

500

4 3 BX

No motor
24 V DC, IP44
24 V DC, low speed, IP44
24 V DC, flat motor, IP44
24 V DC, flat motor, low speed, IP44

0000
C24C
C24CW
D24C
D24CW

Load (N)

CAP 43B.../D24CW
Gear 1
Gear 2
Gear 4

R
L
050
100
200
300
400
500
700

Rear attachment (see page 286):


Fork ear, =12,0 mm
Fork ear, =12,7 mm
Single ear, =12,0 mm
Single ear, =12,7 mm

1 000 1 500 2 000 2 500 3 000 3 500 4 000

Load (N)

CAP 43B.../C24CW

2 500/xx
2 500/33-26
2 500/17-10
2 500/33-22
2 500/20-10

Load (N)

CAP 43B.../C24C
I (A)

Motor options

4 000/xx
4 000/17-13
4 000/9-5
4 000/16-12
4 000/10-5

C A P

1 000 1 500 2 000 2 500 3 000 3 500 4 000

Load (N)

V (mm/s)

CAP 43B

CAP 43B

A1
A2
K1
K2

Front attachment (see page 286):


Hole, =12,0 mm
Hole, =12,7 mm
Male thread, M12
Female thread, M12
Fork ear, =10,1 mm

V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)

G1
G2
G3
G4
G5

Option:
Friction clutch
Back-up nut
Duty cycle

F
S

Option for motors C24C(W):


No cable
Straight, 2,0 m

U
T2

EMC filter

Motor without cover

Duty factor (%) at 20C


100

80

60

40

SKF is a registered trademark of the SKF Group

20

SKF Group 2011


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

0
0

20

40

60

80

100

Load (N)

Printed in Sweden on environmentally friendly paper.


PUB MT/P8 10448 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAHB10 series

Linear actuators DC versions

Connecting diagram

Dimensional drawing
Basic configuration
L1
42

82

18

20

24

18

11

6,4 +0,1
0

6,4 +0,1
0

20
40

(20,5)

Linear actuator

12,5

12/24 V DC
+

CAHB10 series

Ext.

99

Ret.

Black

Red

Limit switches

Benefits

ACME screw drive

Legend:
L1 = retracted length

Actuator

Extension tube (aluminium)


Protection tube (aluminium)

Stroke (mm)*

50

100

150

200

250

300

Retracted length (L1)

158

209

260

311

362

413

Zinc alloy gear housing


Powder metal gears
Self-locking

* Tolerance: S and L1: 2,0 mm

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight (at 300 mm stroke)
Color

* see above table

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAHB10... 1

CAHB10... 2

CAHB10... 3

CAHB10... 4

CAHB10... 5

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

120
120
45 to 56
50 to 300
*
12 or 24
N/A
3,5
2,2
25
40 to +85
66
1,5
Silver

240
240
24 to 30
50 to 300
*
12 or 24
N/A
3,2
2,0
25
40 to +85
66
1,5
Silver

500
500
13 to 16
50 to 300
*
12 or 24
N/A
3,0
1,8
25
40 to +85
66
1,5
Silver

750
750
8 to 10
50 to 300
*
12 or 24
N/A
2,8
1,8
25
40 to +85
66
1,5
Silver

1 000
1 000
6 to 8
50 to 300
*
12 or 24
N/A
2,6
1,6
25
40 to +85
66
1,5
Silver

Linear actuators DC versions

CAHB10 series

CAHB10 series
Ordering key

Performance diagrams

Current consumption (A)

Speed (mm/s)

C A HB 1 0

24 V DC

12 V DC
5,0

60
50
1

40

3,0

10

100

200

300

400

500

600

700

2,0

1,2

1,0

0,6

Voltage:
12 V DC
24 V DC

5
800

900 1 000

100

200

300

400

500

600

700

800

Load (N)

900

Load:
120 N
240 N
500 N
750 N
1 000 N

1 000

Load (N)

Speed-load diagram

Current-load diagram

Screw:
ACME screw

L2=L1+34

82

Optional potentiometer

6,4 +0,1
0
40

6,4 +0,1
0

Retracted length:
Stroke
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm

White
Purple

12,5

A
B
1
2
3
4
5
A

Stroke:
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm

Dimensional drawing
42

0 0 0 0

1,8

20
3

Type

30
2

2,4

4,0

Yellow

133

Retract

050
100
150
200
250
300
w/o POT*
158 mm
209 mm
260 mm
311 mm
362 mm
413 mm

with POT*
192 mm
243 mm
294 mm
345 mm
396 mm
447 mm

IP:
Standard (IP 66)

Extend

Front attachment:
Standard (hole: = 6,4 mm)
Customized

A


White Purple Yellow

Legend:
L1 and L2 = retracted length

CW

Rear attachment:
Standard (hole: = 6,4 mm)
Customized

10K

A


Option 1:
None
Potentiometer
Stroke (mm)*

50

100

150

200

250

300

Retracted length (L2)

192

243

294

345

396

447

0
P

Option 2:
None
Thermal protection

* Tolerance: S and L2: 2,0 mm

0
T

* POT= Potentiometer

Potentiometer resolution
Stroke (mm)

50

100

150

200

250

300

Ohm/mm

94,4

47,2

47,2

15,72

15,72

15,72

SKF is a registered trademark of the SKF Group


SKF Group 2012
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10265 EN February 2012

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAHB20 series

Linear actuators DC versions

Connecting diagram

Dimensional drawing
Basic configuration (dashed line for optional limit switch)

+
12/24 V DC

Ret.

L1

Ext.
73,5

24,5
76

30(55*)

Actuator

28,6
Ferrite Bead
(for 12 V DC only)

63,5

72

Linear actuator

13,1 +0,1
0

47,5

150,5

13,1 +0,1
0

11,5

50,8

38

Black

26

Red

15,5

14

35

47,5

CAHB20 series

13015

161,5

60030

Different rear attachment

AF

30
30

30

Without limit swicth:


RED (+) & BLACK () = retraction
RED () & BLACK (+) = extension
With limit switch:
RED (+) & BLACK () = extension
RED () & BLACK (+) = retraction

30

Benefits

30

ACME screw drive


Extension tube (stainless steel)
Protection tube (steel)

Legend:
L1 = retracted length
*55 = dimension with limit switch

Enhanced corrosion resistance


Mechanical overload protection (clutch)
Lubricated for service life
With limit switch1)

Robust, designed for tough environment

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L1 Retracted length

338

389

440

592

744

897

262

313

364

465

668

821

Self-locking
Certified (CE: EN 55011)

1)

2)

Tolerance: S and L1 = 5,0 mm (If S305 mm, S = 7,5 mm)

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight (at 305 mm stroke)
Color

* see above table

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAHB20... 1

CAHB20... 2

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

1 500
1 500
27 to 33
102 to 610
*
12 or 24
N/A
16
8
25
40 to +85
66
5,5
Black

2 500
2 500
13 to 17
102 to 610
*
12 or 24
N/A
14
7
25
40 to +85
66
5,5
Black

Tolerance: S = 2,5 mm and L1 = 3,8 mm

Linear actuators DC versions

CAHB20 series

CAHB20 series
Ordering key

Performance diagrams

C A HB 2 0

0 0 0

Type
Current consumption (A)
Speed (mm/s)
18

40

16

Voltage:
12 V DC
24 V DC

24 V DC
10

12 V DC

50

8
2

30

20

12

Load:
1 500 N
2 500 N

A
B
1
2

2
10

500

1 000

1 500

2 000

2 500

500

1 000

1 500

2 000

Load (N)

Screw:
Acme screw

Load (N)

Speed-load diagram

Current-load diagram

Retracted length:
Stroke
with L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm
w/o L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

Dimensional drawing
Optional potentiometer (dashed line for optional limit switch)
L2
24,5
76

111,5
30(55*)

15,5

50,8

38

26

Retract

199

Ferrite Bead
(for 12 V DC only)

POT
Limit + POT:

13015

Green
(Red)

45015

60030

Legend:
L2 = retracted length
*55 = dimension with limit switch

Extend

13,1 +0,1
0

13,1 +0,1
0
63,5

150,5

11,5
28,6

14

Without limit swicth:


RED (+) & BLACK () = retraction
RED () & BLACK (+) = extension

With limit switch:


RED (+) & BLACK () = extension
RED () & BLACK (+) = retraction

With limit switch1)

Stroke:
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

2 500

White
(White)
0

Red
(Green)
CW

Black
(Brown)
10K

102
153
204
305
457
610

w/o POT2)
338 mm
389 mm
440 mm
592 mm
744 mm
897 mm

with POT2)
376 mm
427 mm
478 mm
630 mm
782 mm
935 mm

262 mm
313 mm
364 mm
465 mm
668 mm
821 mm

300 mm
351 mm
402 mm
503 mm
706 mm
859 mm

IP:
Standard (IP 66)

White
(White)

Front attachment:
Standard (hole: 13,1 mm)
Customized

Brown
(Black)

A


Rear attachment:
Standard (0 and hole: 13,1 mm)
30
60
90
120
150
Customized

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L2 Retracted length

376

427

478

630

782

935

300

351

402

503

706

859

A
B
C
D
E
F


Option 1:
None
Limit switch (only for load version 2 500 N)

0
L

Option 2:
None
Potentiometer
1)

2)

Tolerance: S and L2 = 5,0 mm (If S 305 mm, S = 7,5 mm)

Tolerance: S = 2,5 mm and L2 = 3,8 mm

Option 3:
None
Thermal protection

Potentiometer resolution

1) L.S.=
2) POT=

Stroke (mm)

102

153

204

305

457

610

Ohm/mm

59,0

59,0

29.5

29.5

9.84

9.84

0
P
0
T

Limit switch
Potentiometer

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10266 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAHB21 series

Linear actuators DC versions


Dimensional drawing

Connecting diagram
+
12/24 V DC

Basic configuration (dashed line for optional limit switch)

Ret.

L1

Ext.
24,5
76

28(53)*

28,6

Black
50,8

26
Actuator

50,8

47,5

Linear actuator

13,1 +0,1
0

72

150,5

13,1 +0,1
0

11,5

15,5

38

Red

73,5

14

161,5

35

47,5

CAHB21 series

Ferrite Bead
(for 12 V DC only)

13015

60030

Different rear attachment

AF

30
30

30

Without limit swicth:


RED (+) & BLACK () = retraction
RED () & BLACK (+) = extension
With limit switch:
RED (+) & BLACK () = extension
RED () & BLACK (+) = retraction

30

Benefits

30

High efficiency ball screw


Extension tube (stainless steel)
Protection tube (steel)

Legend:
L1 = retracted length
* 53 = dimension with limit switch

Enhanced corrosion resistance


Mechanical overload protection (clutch)
Lubricated for service life
With limit switch1)

Robust, designed for tough environment

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L1 Retracted length

393

444

495

659

811

964

317

368

419

521

735

888

No back driving
Certified (CE: EN 55011)

1)

2)

Tolerance: S, L1 and L2 = 5,0 mm (If S305 mm, S = 7,5 mm)

Tolerance: S = 2,5 mm and L1, L2 = 3,8 mm

Technical data

Push load
Pull load
Speed (full load to no load)
Stroke
Retracted length
Voltage
Power consumption
Current consumption 12 V DC
24 V DC
Duty cycle
Ambient temperature
Type of protection
Weight (at 305 mm stroke)
Color

* see above table

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAHB21... 1

CAHB21... 2

CAHB21... 3

N
N
mm/s
mm
mm
V DC
W
A
A
%
C
IP
kg

2 300
2 300
45 to 65
102 to 610
*
12 or 24
N/A
22
11
25
40 to +85
66
6,5
Black

3 500
3 500
24 to 36
102 to 610
*
12 or 24
N/A
17
8,5
25
40 to +85
66
6,5
Black

4 500
4 500
14 to 19
102 to 610
*
12 or 24
N/A
13
6,5
25
40 to +85
66
6,5
Black

Linear actuators DC versions

CAHB21 series

CAHB21 series

Performance diagrams

C A HB 2 1

0 0 0

Type
Voltage:
12 V DC
24 V DC

Current consumption (A)


Speed (mm/s)

12 V DC

24 V DC
1

Load:
2 300 N
3 500 N
4 500 N

10

20

60

2
1

45

15

10

30

7,5

1 000

2 000

3 000

4 000

Screw:
Ball screw

2,5

5 000

1 000

2 000

3 000

4 000

Load (N)

5 000

Current-load diagram

Retracted length:
Stroke
with L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm
w/o L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

Dimensional drawing
Optional potentiometer (dashed line for optional limit switch)
L2
111,5

24,5
14

28(53)*

11,5

26

50,8

28,6

15,5

Retract

13,1 +0,1
0

Extend

13,1 +0,1
0
Ferrite Bead
(for 12 V DC only)

63,5

150,5

38

76

199

White
(White)
0

POT
Limit + POT:

13015

60030

Red
(Green)
CW

Black
(Brown)
10K

with POT2)
431 mm
482 mm
533 mm
697 mm
849 mm
A02 mm (1 002 mm)

317mm
368 mm
419 mm
521 mm
735 mm
888 mm

355 mm
406 mm
457 mm
559 mm
773 mm
926 mm
A
A


Rear attachment:
Standard (0 and hole: 13,1 mm)
30
60
90
120
150
Customized

With limit switch:


RED (+) & BLACK () = extension
RED () & BLACK (+) = retraction

With limit switch1)

w/o POT2)
393 mm
444 mm
495 mm
659 mm
811mm
964 mm

Front attachment:
Standard (hole: 13,1 mm)
Customized

Brown
(Black)

Without limit swicth:


Legend:
RED (+) & BLACK () = retraction
L2 = retracted length
* 53 = dimension with limit switch RED () & BLACK (+) = extension

102
153
204
305
457
610

IP:
Standard (IP 66)

White
(White)

Green
(Red)

45015

Stroke:
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

Load (N)

Speed-load diagram

1
2
3

2
15

A
B

12,5

25

75

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L2 Retracted length

431

482

533

697

849

1 002

355

406

457

559

773

926

A
B
C
D
E
F


Option 1:
None
Limit switch (only for load version 4 500 N)

0
L

Option 2:
None
Potentiometer
1)

2)

Tolerance: S and L2 = 5,0 mm (If S 305 mm, S = 7,5 mm)

0
P

Tolerance: S = 2,5 mm and L2 = 3,8 mm

Option 3:
None
Thermal protection
Potentiometer resolution

1) L.S.=
2) POT=

Stroke (mm)

102

153

204

305

457

610

Ohm/mm

59,0

59,0

29,5

29,5

9,84

9,84

0
T

Limit switch
Potentiometer

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10267 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAHB30 series

Linear actuators AC versions

Connecting diagram

Dimensional drawing

115/230 V AC, 50/60 Hz


L
N
PE

Basic configuration (dashed line for optional limit switch)

Ext.

Green

Red

Ret.

Black

White
L1

Linear actuator

24,5

76

87

47,5

13,1 +0,1
0

72

156

13,1 +0,1
0

CAHB30 series

11,5

50,8

38

30(55)*

26

73,5
15,5

14

28,6

Actuator

Different rear attachment


47,5

60030

30
30

30

30

30
B

269

Benefits

35

AF

ACME screw drive


Extension tube (stainless steel)
Protection tube (steel)

Legend:
L1 = retracted length
* 55 = dimension with limit switch

Enhanced corrosion resistance


Mechanical overload protection (clutch)
Lubricated for service life
With limit switch1)

Robust, designed for tough environment

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L1 Retracted length

440

440

440

592

744

897

380

415

415

465

668

821

Self-locking
Motor with thermal protection

1)

2)

Tolerance: S and L1 = 5,0 mm (If S305 mm, S = 7,5 mm)

Tolerance: S = 2,5 mm and L1 = 3,8 mm

Technical data

Push load
Pull load
Speed (full load to no load) 115 VAC/60 Hz
230 VAC/50 Hz
Stroke
Retracted length
Voltage
Power consumption
Current consumption
115 V AC/60 Hz
230 V AC/50 Hz
Duty cycle
Ambient temperature
Type of protection
Weight (at 305 mm stroke)
Color

* See above table

For outdoors application, please contact SKF.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAHB30... 1

CAHB30... 2

N
N
mm/s
mm/s
mm
mm
V AC
W
A
A
%
C
IP
kg

1 500
1 500
25 to 26
21 to 22
102 to 610
*
115 or 230
N/A
2,3
1,35
25
26 to +65
65
9
Black

2 300
2 300
12 to 13
11 to 12
102 to 610
*
115 or 230
N/A
1,8
1,4
25
26 to +65
65
9
Black

Linear actuators AC versions

CAHB30 series

CAHB30 series
Ordering key

Performance diagrams

C A HB 3 0
Speed (mm/s)

0 0 0 0

Current consumption (A)

30

2,5

Type

1 (115 VAC)
1 (115 VAC)
24

Voltage:
115 V AC
230 V AC

2,0
2 (115 VAC)
1 (230 VAC)

18

Load:
1 500 N
2 300 N

1 (230 VAC)
2 (115 VAC)
12

1,0
2 (230 VAC)

0,5

0
0

500

1 000

1 500

2 000

2 500

Screw:
Acme screw
0

500

1 000

1 500

2 000

Load (N)

2 500

Current-load diagram

Retracted length:
Stroke
with L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm
w/o L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

Dimensional drawing
Optional potentiometer (dashed line for optional limit switch)
L2
24,5

11,5

30(55)*

50,8

26

38

Retract

13,1 +0,1
0

Extend

13,1 +0,1
0
87

156

111,5
15,5

14

28,6

76

306,5

POT
Limit + POT:

60030

White
(White)
0

Red
(Green)
CW

Black
(Brown)
10K

White
(White)

Green
(Red)

Legend
L2 = retracted length
* 55 = dimension with limit switch

Motor
Green

White Retraction

w/o POT2)
440 mm
440 mm
440 mm
592 mm
744 mm
897 mm

with POT2)
478 mm
478 mm
478 mm
630 mm
782 mm
935 mm

380 mm
415 mm
415 mm
465 mm
668 mm
821 mm

418 mm
453 mm
453 mm
503 mm
706 mm
859 mm
A
A


Ground

With limit switch1)

Rear attachment:
Standard (0 and hole: 13,1 mm)
30
60
90
120
150
Customized

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L2 Retracted length

478

478

478

630

782

935

418

453

453

503

706

859

1)

102
153
204
305
457
610

Front attachment:
Standard (hole: 13,1 mm)
Customized

Brown
(Black)

115/230 V AC
60/50 Hz

IP:
Standard (IP 65)

45015
Red
Extension
Black

1
2

Stroke:
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

Load (N)

Speed-load diagram

N
P

2 (230 VAC)

1,5

2)

Tolerance: S and L2 = 5,0 mm (If S305 mm, S = 7,5 mm)

Option 1:
None
Limit switch (only for load version 2 300 N)

1) L.S.=
2) POT=

102

153

204

305

457

610

Ohm/mm

59,0

59,0

29,5

29,5

9,84

9,84

0
L

Option 2:
None
Potentiometer

Tolerance: S = 2,5 mm and L2 = 3,8 mm

Potentiometer resolution
Stroke (mm)

A
B
C
D
E
F


0
P

Limit switch
Potentiometer

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10268 EN February 20111

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CAHB31 series

Linear actuators AC versions


Dimensional drawing

Connecting diagram

Basic Configuration (dashed line for optional limit switch)

115/230 V AC, 50/60 Hz


L
N
PE

Ext.

Green

Red

Ret.

Black

White
L1

50,8

38

28(53)*

26

73,5

13,1 +0,1
0

72

87

47,5

156

13,1 +0,1
0

CAHB31 series

11,5

15,5

14

28,6

Linear actuator

24,5

76

Actuator

Different rear attachment

30
30

30

30

30
B

60030

Benefits

269

35

47,5
D

AF

High efficiency ball screw


Extension tube (stainless steel)
Protection tube (steel)

Legend:
L1 = retracted length
* 53 = dimension with limit switch

Enhanced corrosion resistance


Mechanical overload protection (clutch)
Lubricated for service life
With limit switch1)

Robust, designed for tough environment

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L1 Retracted length

444

444

495

659

811

964

380

419

419

521

735

888

No back driving
Motor with thermal protection

1)

2)

Tolerance: S and L1 = 5,0 mm (If S305 mm, S = 7,5 mm)

Tolerance: S = 2,5 mm and L1 = 3,8 mm

Technical data

Push load
Pull load
Speed (full load to no load) 115 VAC/60 Hz
230 VAC/50 Hz
Stroke
Retracted length
Voltage
Power consumption
Current consumption
115 V AC/60 Hz
230 V AC/50 Hz
Duty cycle
Ambient temperature
Type of protection
Weight (at 305 mm stroke)
Color

* See above table

For outdoors application, please contact SKF.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CAHB31... 1

CAHB31... 2

CAHB31... 3

N
N
mm/s
mm/s
mm
mm
V AC
W
A
A
%
C
IP
kg

2 300
2 300
48 to 57
40 to 50
102 to 610
*
115 or 230
N/A
3
1,5
25
26 to +65
65
9,5
Black

4 500
4 500
22 to 28
20 to 24
102 to 610
*
115 or 230
N/A
2,6
1,4
25
26 to +65
65
9,5
Black

6 000
6 000
13 to 15
11 to 13
102 to 610
*
115 or 230
N/A
2,2
1,4
25
26 to +65
65
9,5
Black

Linear actuators AC versions

CAHB31 series

CAHB31 series
Ordering key

Performance diagrams

C A HB 3 1
Speed (mm/s)

75

3,0

Type

1 (115 VAC)
2 (115 VAC)

60

2,4

1 (115 VAC)

45

3 (115 VAC)

Voltage:
115 V AC
230 V AC

3 (230 VAC)

Load:
2 300 N
4 500 N
6 000 N

1,8
1 (230 VAC)

1 (230 VAC)
30

2 (230 VAC)

1,2
2 (115 VAC)
2 (230 VAC)
3 (115 VAC)

15

0,6

N
P
1
2
3

Screw:
Ball screw

3 (230 VAC)

0
0

1 000

2 000

3 000

4 000

5 000

6 000

1 000

2 000

3 000

4 000

5 000

Stroke:
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

6 000

Load (N)

Load (N)

Speed-load diagram

Current-load diagram

Dimensional drawing

Retracted length:
Stroke
with L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm
w/o L.S.1)
102 mm
153 mm
204 mm
305 mm
457 mm
610 mm

Optional potentiometer (dashed line for optional limit switch)


L2
24,5

28(53)*

11,5
28,6

38

13,1 +0,1
0

Retract

13,1 +0,1
0

Extend

87

156

111,5
15,5

26

14

50,8

76

POT
Limit + POT:
306,5

60030

Green
(Red)

45015

Legend:
L2 = retracted length
* 53 = dimension with limit switch

Motor
Green

Red
Extension
Black

White
(White)
0

Black
(Brown)
10K

Red
(Green)
CW

White
(White)

102
153
204
305
457
610

w/o POT2)
444 mm
444 mm
495 mm
659 mm
811 mm
964 mm

with POT2)
482 mm
482 mm
533 mm
697 mm
849 mm
A02 mm (1 002 mm)

380 mm
419 mm
419 mm
521 mm
735 mm
888 mm

418 mm
457 mm
457 mm
559 mm
773 mm
926 mm

IP:
Standard (IP 65)

Front attachment:
Standard (hole: 13,1 mm)
Customized

Brown
(Black)

115/230 V AC
60/50 Hz

White Retraction

A


Ground

With limit switch1)

Rear attachment:
Standard (0 and hole: 13,1 mm)
30
60
90
120
150
Customized

Without limit switch2)

Stroke (mm)

102

153

204

305

457

610

102

153

204

305

457

610

L2 Retracted length

482

482

533

697

849

1 002

418

457

457

559

773

926

A
B
C
D
E
F


Option 1:
None
Limit switch (only for load version 6 000 N)
1)

0 0 0 0

Current consumption (A)

2)

Tolerance: S, L1 and L2 = 5,0 mm (If S305 mm, S = 7,5 mm)

Tolerance: S = 2,5 mm and L1, L2 = 3,8 mm

Option 2:
None
Potentiometer

Potentiometer resolution

1) L.S.=
2) POT=

Stroke (mm)

102

153

204

305

457

610

Ohm/mm

59,0

59,0

29,5

29,5

9,84

9,84

0
L
0
P

Limit switch
Potentiometer

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10269 EN February 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

SJ 25, 35, 45 series

Linear actuators AC versions


Dimensional drawing

Connecting diagram

10

12

37

L = S + 190/200/215

Metallic outer tube


73
152,5

10

Linear actuator

36

(126)

132

SJ 25, 35, 45 series


12

L = S + 190/200/215

37

10

115/230 V AC, 50/60 Hz


L
N
PE

Plastic dust cover


73
152,5

10

Benefits
Motor with thermal protection (+120 5 C)

Green

Red

Black

White

45
88

Acme
Actuator

Self-lo

Integr

Legend:
S = stroke
L = retracted length

Potent
Gear b

Mountings

UL 10

43

53,5
25

10

57

80
25,2

20

57

36

53,5

10

80

80

14,5-4

36

36

01

02
45
25

44

55

45

13
10
44

15

25

55

80

80

10,5

36

36

03

04
53,5
20

43

25
53,5

10

80

10

36

05

* Only as an option for SJ35 and SJ45


Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Linear actuators AC versions

Ordering key

Technical data

Push load
Pull load
Speed (full load
115 V AC
to no load)
230 V AC
Stroke1)
Retracted length2)
Voltage
Power consumption
Current consumption 115 V AC
230 V AC
Duty cycle
Ambient temperature
Type of protection
Weight
Color

1)
2)

Unit

SJ 255

SJ 256

SJ 258

SJ 355

SJ 356

SJ 358

N
N
mm/s
mm/s
mm
mm
V AC
W
A
A
%
C
IP
kg

2 000
2 000
6,6 to 7,2
5,4 to 5,9
100 to 600
S+190/200/215
115 or 230
N/A
1,4
0,8
17
+10 to +40
52
4,0
Black

2 500
2 500
5,5 to 6,0
4,4 to 4,9
100 to 600
S+190/200/215
115 or 230
N/A
1,4
0,8
17
+10 to +40
52
4,0
Black

3 000
3 000
4,0 to 4,5
3,3 to 3,7
100 to 600
S+190/200/215
115 or 230
N/A
1,4
0,8
17
+10 to +40
52
4,0
Black

3 000
3 000
6,6 to 7,2
5,4 to 5,9
100 to 600
S+190/200/215
115 or 230
N/A
1,6
1,0
17
+10 to +40
52
4,5
Black

3 500
3 500
5,5 to 6,0
4,4 to 4,9
100 to 600
S+190/200/215
115 or 230
N/A
1,6
1,0
17
+10 to +40
52
4,5
Black

4 000
4 000
4,5 to 3,7
3,3 to 3,7
100 to 600
S+190/200/215
115 or 230
N/A
1,6
1,0
17
+10 to +40
52
4,5
Black

S J

Load / Speed:
2 000 N / 7,2 mm/s
2 500 N / 6,0 mm/s
3 000 N / 4,5 mm/s
3 000 N / 7,2 mm/s
3 500 N / 6,0 mm/s
4 000 N / 4,5 mm/s
4 000 N / 7,2 mm/s
4 500 N / 6,0 mm/s
5 000 N / 4,5 mm/s

2)

SJ 455

SJ 456

SJ 458

N
N
mm/s
mm/s
mm
mm
V AC
W
A
A
%
C
IP
kg

4 000
4 000
6,6 to 7,2
5,4 to 5,9
100 to 600
S+190/200/215
115 or 230
N/A
1,8
1,0
17
+10 to +40
52
5,0
Black

4 500
4 500
5,5 to 6,0
4,4 to 4,9
100 to 600
S+190/200/215
115 or 230
N/A
1,8
1,0
17
+10 to +40
52
5,0
Black

5 000
5 000
4,0 to 4,5
3,3 to 3,7
100 to 600
S+190/200/215
115 or 230
N/A
1,8
1,0
17
+10 to +40
52
5,0
Black

2,0

35X-115V
25X-115V

1,0
358

XX

Options written in italic fonts are only available on demand. Please contact SKF

1,5

4
258

100
150
200
250
300
350
400
450
500
550
600

Customized cable length options:


Specify requested cable length in dm

456

356

256

P
N

Stroke:
100 mm
150 mm
200 mm
250 mm (250 mm is also the maximum stroke for tube versions I and Y)
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm

45X-115V

455

355

255

N
C
P
L

Feedback:
Potentiometer
No sensor

Current consumption (A)


2,5

01
02
03
04
05

Cable connector:
No connector
1x4C to control box
1x3C to AC plug, 1x3C to pedant
With one motor controller

Performance diagrams

Speed (mm/s)

B
I
Y

Mounting (see illustrations on page 141):


Square mounting
Tube mounting with 4 holes
Clevis mounting
Clevis mounting
Square mounting

Max. stroke for the tube version I is 250 mm.


For clevis mounting; 01 and 05 L=S+190 mm, 02 L=S+215 mm, 03 and 04 L=S+200 mm.

10

115
230

Tube type:
With outer and inner tube
Inner tube with plastic dust protection cover
Inner tube only

Unit

255
256
258
355
356
358
455
456
458

Voltage:
115 V AC
230 V AC

Max. stroke for the tube version I is 250 mm.


For clevis mounting; 01 and 05 L=S+190 mm, 02 L=S+215 mm, 03 and 04 L=S+200 mm.

Push load
Pull load
Speed (full load
115 V AC
to no load)
230 V AC
Stroke1)
Retracted length2)
Voltage
Power consumption
Current consumption 115 V AC
230 V AC
Duty cycle
Ambient temperature
Type of protection
Weight
Color

Type

Technical data

1)

SJ 25, 35, 45 series

SJ 25, 35, 45 series

458

25X-230V
45X-230V

0,5

35X-230V

1 000

2 000

3 000

4 000

5 000

1 000

2 000

3 000

Load (N)

Speed-load diagram

4 000

5 000

Load (N)

SKF is a registered trademark of the SKF Group


SKF Group 2009
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

Current-load diagram

Printed in Sweden on environmentally friendly paper.


PUB MT/P8 10355 EN November 2009

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CASD60

Linear actuators

Dimensional drawing

Retracted length: stroke + 434


145,5
46

145,5

CASD60

50

20

160

87

80

120

85,6

108,8

Linear actuator

12

25

+
0 0
,0
5

Benefits
 Specifically designed for solar tracking applications
 Up to 20 years life
 Limited backlash
 High accuracy
 Low current consumption
 Plug and play solution
 Assembled, lubricated, and sealed for life

Stroke (mm)

From 50 to 1 500*

Installed dimension L1

Selectable from a minimum of 200 mm to a maximum of stroke + 150 mm

 Designed to withstand severe outdoor conditions


 Virtually maintenance free

* For stroke > 1 000 mm, static load needs to be verified

Technical data

Dynamic load (push/pull)


Static load (push/pull)
Speed
Stroke
Voltage
Integrated limit switches
Feedback positioning
Feedback positioning resolution
Operating temperature
Type of protection

Electro Mechanical Systems Limited

34
L1

20

99,5

202,8

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CASD60

N
N
mm/s
mm
V

pulses/mm
C
IP

12 000
60 000 (up to 1 000 mm stroke)
up to 2,5
up to 1 500
12/24 V DC or 120/230 V AC
optional
optional (encoder)
49 or 67
20 to +60
65

25

+
0 0
,0
1

Linear actuators

CASD60

Trunnion mount designs

Telemag CPT

The Power of Knowledge Engineering


Seals

Bearings
and units

Lubrication
systems

25 +0,071
0,010

Services

120

20

Mechatronics

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

Ordering key
Trunnion 25 mm bushings

C A S D 6 0

20

Motor type:
12 V DC
24 V DC
120 V AC
230 V AC

N 0 0

A
B
N
P

Maximum Dynamic Load/Speed:


12 000 N - 1,8 mm/s

120

160

1 A

Type

0
25 0,05

Screw type:
Trapezoidal

Stroke in mm:
For 3-digit stroke dimension:
For 4-digit stroke dimension:

0XXX
XXXX

Trunnion 25 mm pins

Installed dimension in mm*:


For 3-digit installed dimension:
For 4-digit installed dimension:

0XXX
XXXX

IP protection:
IP65

Connecting diagram

Front attachment:
25 mm rod end
20 mm rod end
Other

12/24 V DC
+

5V+
GND
1,5K

1,5K

Rear attachment:
Trunnion 25 mm pins
Trunnion 25 mm bushings
Other

Hall A
Hall B
DIN8 plug
1+7

2+4
Blue

Limit switches

A
B
X
A
B
X

3 5 6 8

Option 1:
None
Limit switches
Other

Red
2 Hallsensors signal
Option

N
L
X

Option 2:
None
Encoder
Other

Actuator

N
E
X

* Distance between front attachment and trunnion mount.

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12235 EN November 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Linear units

CASM32

CASM32

Dimensional drawing
148 1 + Stroke

22

Linear units

15,9

24
44,5

26

6h6

11

12

16

30d11

M10x1,25

18

M6

Technical data

16

16

32f7

26

45,5

Screw type
Screw diameter
Screw pitch
Max. dynamic force
Max. static force
Max. speed
Stroke
Max. input torque*
Max. input RPM*
Max. acceleration
Duty cycle
Lifetime L10
Repeatability (same direction and load)
Operating temperature
Humidity
Type of protection

Unit

CASM32LS

CASM32BS

CASM32BN

mm
mm
N
N
mm/s
mm
Nm
1/min
m/s2
%
km
mm
C
%
IP

Lead screw
9
1,5
300
700
60
50 to 400
0,5
2 400
1
60
70
0,07
0 to +50
95
54S

Ball screw
10
3
700
700
150
50 to 400
0,8
3 000
6
100
see chart
0,01
0 to +50
95
54S

Ball screw
10
10
630
700
500
50 to 400
1,4
3 000
6
100
see chart
0,01
0 to +50
95
54S

32,5

32,5

Slots for proximity sensor


with option M

Slots for proximity sensor


with option M
M6

M6

Ordering key

* Speed and torque of the motor needs to be limited

C A SM 3 2
Performance diagrams CASM32

0 0 0

Type

Force (N)

Screw:
Lead screw 91,5 mm
Ball screw 103 mm
Ball screw 1010 mm

Nominal load (N)

Radial load (N)

300

1 000

700

500

LS
BS
BN

600

250

Stroke:
50 mm
100 mm
150 mm
200 mm
300 mm
400 mm

500

100

200

50

400

150
300
100

10
200

050
100
150
200
300
400

5
50

Option1):
Motor, adapter and accessories separately delivered
Motor, adapter and foot mountings2) pre-mounted (see orientation of slots on above drawing)

100
1
200

300

400

500

600

700

800

Position (mm)

Radial load diagram


The radial load acts perpendicular to the
moving direction.

Lifetime diagram
CASM32BN
CASM32BS

9 000

100

A
M

10 000

Speed (mm/s)

Speed force diagram CASM32LS


No limitation for ball screw types (max. load
at max. speed).

0
0

8 000

60

6 000

50

7 000

40

5 000

30

3 000

20

4 000

10

2 000

1 000

Lifetime (Km)

1) Motor,
2) Foot

adapter kit and accessories need to be ordered separately


mountings pre-mounted on in-line version only

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12148 EN September 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Siemens motors and adapters

CASM32

CASM32
Order N
ZBE375530

In-line adapter kit for CASM-32 and Siemens 1FK7015 motor*

Siemens motors and adapters

46

40,9

40

System capabilities

In order to provide you a fully integrated system, SKF combined its


actuator expertise with Siemens well-known motor knowledge.
Thanks to this partnership, SKF offers a complete linear solution, including a CASM linear unit mounted with a SIEMENS 1FK7
servomotor.
The Siemens motors 1FK7015 and 1FK7022 come with a
multipole resolver, a shaft-end with no keyway and a holding brake.
In addition, the 1FK7022 model is equipped with a DRIVE-CLiQ interface. A rotating plug adapter simplifies the connection and cable
routing in all installation positions.

For more information, please visit the following sites:


Motors: www.siemens.com/motors
Frequency converters: www.siemens.com/sinamics
Automation systems: www.siemens.com/simotion
Controls: www.siemens.com/simatic
Engineering software: www.siemens.com/sizer
Support worldwide: www.siemens.de/service

CASM32LS
CASM32BS
CASM32BN

4M4

* Screws included

1)

Unit

Peak force

Fm1)

N
N
N

300
700
450

203
293
151

RMS force over full cycle. For more information, please visit www.skf.com/casm

Solution with Siemens motor 1FK7022 and compatible adapter


Order N
1FK70225AK711UH3

Dimensional drawing Siemens motor 1FK7022

Motor data

Solutions with Siemens motor 1FK7015 and compatible adapters


Order N
1FK70155AK711SH3

103

Dimensional drawing Siemens motor 1FK7015

0,1
6 000
0,85
0,16
0,35
1
0,102
20
1,2

kW
min-1
A
Nm
Nm
Nm
104 kgm2
mm
kg

55

1FK7015

40

Motor data
Unit

40

30

86

18

165

Rated power (100 K)


Rated speed
Rated current
Rated torque (100 K)
Static torque (100 K)
Peak torque
Inertia with brake
Shaft height
Weight with brake

Unit

1FK7022

kW
min-1
A
Nm
Nm
Nm
104 kgm2
mm
kg

0,43
6 000
1,4
0,6
0,85
3,4
0,35
28
2

20

175

Rated power (100 K)


Rated speed
Rated current
Rated torque (100 K)
Static torque (100 K)
Peak torque
Inertia with brake
Shaft height
Weight with brake

Order N
ZBE375531

In-line adapter kit for CASM32 and Siemens 1FK7022 motor*

64

49,4

Order N
ZBE375540

Parallel adapter kit for CASM32 and Siemens 1FK7015 motor*

55

System capabilities

4M4

4M5

7
40,1

CASM32LS
CASM32BS
CASM32BN

* Screws included

CASM32LS
CASM32BS
CASM32BN

11

System capabilities

30

93,3

46

30 F7

45,1

1)

Unit

Peak force

Fm1)

N
N
N

300
700
450

203
293
151

* Screws included

1)

Unit

Peak force

Fm1)

N
N
N

300
700
630

300
672
357

RMS force over full cycle. For more information, please visit www.skf.com/casm

RMS force over full cycle. For more information, please visit www.skf.com/casm

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12189 EN October 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Accessories

CASM32

CASM32
45

Swivel flange*

Order N
ZBE37550432
For parallel version only

22

41

10

10

6,6

Accessories

5,5
9

14
34

* Screws included

Part 2

18

10,5

Order N
ZBE37550232

10

Order N
ZBE37551032

10

* Screws included

M10x1,25

Order N
ZBE37550332

14

14
10,5

Rod eye

Order N
ZBE37551132

29

43

46

12

10

Trunnion
flange kit*

* Screws included

28
20
10

Rod clevis

80

64

22

Note: The foot mounting between the linear unit and the
adapter kit increases the length of the in-line version by 4 mm

32

14

* Screws included

45

Flange
mounting kit*

5,5

10

58
71

20

24

40

11

32

16

Order No
ZBE37550732
For in-line version
(part 1 + part 2)

6,6

Part 1

Order N
ZBE37550632
For parallel version only

45

Swivel flange
with rod eye*

10

Order N
ZBE37550132
For parallel version
(2x part 1)

Foot mounting kit*

145

50

12

* Screws included

17

Order N
ZBE37550832

30

Order N
C375525NO

3,15

Proximity
sensor

29

12

LED

50

6,2

12

Trunnion
mounting kit*

15
20

12
65

* Screws included
Order N
ZBE37550932

18
6,6

Normally open
PNP
24 V DC
30 mA
5m

30

6,8

10,5

15

Trunnion
support pair

Switching function
Output signal
Rated voltage
Max. current
Cable length

SKF is a registered trademark of the SKF Group


12

1:2

32
46

Note: to be used with trunnion


flange kit or trunnion mounting kit

SKF Group 2011


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12190 EN September 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Linear units

CASM40

CASM40

Dimensional drawing
176,5 1 + Stroke

24

8h6

11

30

16

20

35d11

M12x1,25

21,5

M6

Technical data

16

16

40f7

Linear units

18,4

28,5
53

30

14

54

Screw type
Screw diameter
Screw pitch
Max. dynamic force
Max. static force
Max. speed
Stroke
Max. input torque*
Max. input RPM*
Max. acceleration
Duty cycle
Lifetime L10
Repeatability (same direction and load)
Operating temperature
Humidity
Type of protection

Unit

CASM40LS

CASM40BS

CASM40BN

mm
mm
N
N
mm/s
mm
Nm
1/min
m/s2
%
km
mm
C
%
IP

Lead screw
12,5
2,5
600
1 500
70
100 to 600
1,2
1 680
1
60
100
0,07
0 to +50
95
54S

Ball screw
12
5
2 375
2 375
300
100 to 600
2,9
3 600
6
100
see chart
0,01
0 to +50
95
54S

Ball screw
12,7
12,7
1 550
2 375
825
100 to 600
4
3 900
6
100
see chart
0,01
0 to +50
95
54S

38

38

Slots for proximity sensor


with option M

Slots for proximity sensor


with option M
M6

M6

Ordering key

* Speed and torque of the motor needs to be limited

C A SM 4 0
Performance diagrams CASM40

0 0 0

Type
Radial load (N)

Force (N)
600

Screw:
Lead screw 12,52,5 mm
Ball screw 125 mm
Ball screw 12,712,7 mm

Nominal load (N)

1 000

2 200

500

2 000

500

LS
BS
BN

1 800

Stroke:
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm

1 600
100

400

1 400
50

1 200

300
1 000
800

10

200

600

400

100

200
1
100

200

300

400

500

600

700

800

Position (mm)

Radial load diagram


The radial load acts perpendicular to the
moving direction.

Lifetime diagram
CASM40BN
CASM40BS

9 000

Speed (mm/s)

Speed force diagram CASM40LS


No limitation for ball screw types (max. load
at max. speed).

10 000

70

8 000

60

7 000

50

6 000

40

5 000

30

4 000

20

3 000

10

2 000

0
1 000

Lifetime (Km)

100
200
300
400
500
600

Option1):
Motor, adapter and accessories separately delivered
Motor, adapter and foot mountings2) pre-mounted (see orientation of slots on above drawing)

1)
2)

A
M

Motor, adapter kit and accessories need to be ordered separately


Foot mountings pre-mounted on in-line version only

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12160 EN September 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Siemens motors and adapters

CASM40

CASM40
Order N
ZBE375532

In-line adapter kit for CASM40 and Siemens 1FK7022 motor*

Siemens motors and adapters

49,4

64

55

System capabilities

In order to provide you a fully integrated system, SKF combined its


actuator expertise with Siemens well-known motor knowledge.
Thanks to this partnership, SKF offers a complete linear solution, including a CASM linear unit mounted with a SIEMENS 1FK7
servomotor.
The Siemens motors 1FK7022 and 1FK7034 come with a
multipole resolver, a shaft-end with no keyway and a holding brake.
In addition, they are equipped with a DRIVE-CLiQ interface. A rotating plug adapter simplifies the connection and cable routing in all installation positions.

For more information, please visit the following sites:


Motors: www.siemens.com/motors
Frequency converters: www.siemens.com/sinamics
Automation systems: www.siemens.com/simotion
Controls: www.siemens.com/simatic
Engineering software: www.siemens.com/sizer
Support worldwide: www.siemens.de/service

CASM40LS
CASM40BS
CASM40BN

11

4M5

* Screws included

1)

Unit

Peak force

Fm1)

N
N
N

600
2 375
1 318

408
640
301

RMS force over full cycle. For more information, please visit www.skf.com/casm

Solution with Siemens motor 1FK7034 and compatible adapter


Order N
1FK70345AK711UH3

Dimensional drawing Siemens motor 1FK7034

Motor data

Solutions with Siemens motor 1FK7022 and compatible adapters


Order N
1FK70225AK711UH3

117

Dimensional drawing Siemens motor 1FK7022

0,43
6 000
1,4
0,6
0,85
3,4
0,35
28
2

72

kW
min-1
A
Nm
Nm
Nm
104 kgm2
mm
kg

14

1FK7022

60

Motor data
Unit

55

40

103

20

175

Rated power (100 K)


Rated speed
Rated current
Rated torque (100 K)
Static torque (100 K)
Peak torque
Inertia with brake
Shaft height
Weight with brake

Unit

1FK7034

kW
min-1
A
Nm
Nm
Nm
104 kgm2
mm
kg

0,63
6 000
1,3
1
1,6
6,5
0,98
36
4

30

200

Rated power (100 K)


Rated speed
Rated current
Rated torque (100 K)
Static torque (100 K)
Peak torque
Inertia with brake
Shaft height
Weight with brake

Order N
ZBE375533

In-line adapter kit for CASM40 and Siemens 1FK7034 motor*

78

52,4

Order N
ZBE375541

Parallel adapter kit for CASM40 and Siemens 1FK7022 motor*

115,3

4M6

System capabilities
Unit

Peak force

Fm1)

N
N
N

600
2 375
1 550

408
640
301

14

* Screws included

CASM40LS
CASM40BS
CASM40BN
1)

Unit

Peak force

Fm1)

N
N
N

600
2 375
1 550

600
1 219
572

RMS force over full cycle. For more information, please visit www.skf.com/casm

35

4M5

64

40 F7

72

System capabilities

CASM40LS
CASM40BS
CASM40BN

7
47,1

* Screws included

1)

RMS force over full cycle. For more information, please visit www.skf.com/casm

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12194 EN October 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Accessories

CASM40

CASM40
52

Swivel flange*

Order N
ZBE37550440
For parallel version only

25

48

12

12

6,6

Accessories

5,5
9

16
40

* Screws included

Part 2

28

20,5

12

11,5

* Screws included

52

* Screws included

Order N
ZBE37551040

M12x1,25

Order N
ZBE37550340

19

16
12

Rod eye

Order N
ZBE37551140

33

50

59

16

12

Trunnion
flange kit*

* Screws included

32
24
12

Rod clevis

12

72

25

Order N
ZBE37550240

10

36

Note: The foot mounting between the linear unit and the
adapter kit increases the length of the in-line version by 4 mm

90

Flange
mounting kit*

5,5

16

72
90

48

36

6,6

19

Order N
ZBE37550740
For in-line version
(part 1 + part 2)

24

Part 1

Order N
ZBE37550640
For parallel version only

52

Swivel flange
with rod eye*

12

Order N
ZBE37550140
For parallel version
(2x part 1)

Foot mounting kit*

145

63

16

* Screws included

19

Order N
ZBE37550840

32

Order N
C375525NO

3,15

Proximity
sensor

29
16

LED

63

6,2

16

Trunnion
mounting kit*

17,5
23

16
75

* Screws included
Order N
ZBE37550940

21
9

Normally open
PNP
24 V DC
30 mA
5m

36

12

18

Trunnion
support pair

Switching function
Output signal
Rated voltage
Max. current
Cable length

SKF is a registered trademark of the SKF Group


16

1:2

36
55

Note: to be used with trunnion flange


kit or trunnion mounting kit

SKF Group 2011


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12191 EN September 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Linear units

CASM63

CASM63

Dimensional drawing
214 1 + Stroke

32

12h6

17

36

20

28

45d11

M16x1,5

28,5

M8

Technical data

17

17

17

75,5

Screw type
Screw diameter
Screw pitch
Max. dynamic force
Max. static force
Max. speed
Stroke
Max. input torque*
Max. input RPM*
Max. acceleration
Duty cycle
Lifetime L10
Repeatability (same direction and load)
Operating temperature
Humidity
Type of protection

Unit

CASM63LS

CASM63BN

CASM63BF

mm
mm
N
N
mm/s
mm
Nm
1/min
m/s2
%
km
mm
C
%
IP

Lead screw
20
4
1 000
3 700
70
100 to 800
3
1 050
1
60
100
0,07
0 to +50
95
54S

Ball screw
20
10
5 400
5 400
530
100 to 800
11,5
3 200
6
100
see chart
0,01
0 to +50
95
54S

Ball screw
20
20
2 800
5 400
1 060
100 to 800
11,5
3 200
6
100
see chart
0,01
0 to +50
95
54S

56,5

56,5

Slots for proximity sensor


with option M

Slots for proximity sensor


with option M
M8

M8

Ordering key

* Speed and torque of the motor needs to be limited

C A SM 6 3

0 0 0

Type
Performance diagrams CASM63
Radial load (N)
5 400
5 100
4 800
4 500
4 200
3 900
3 600
3 300
3 000
2 700
2 400
2 100
1 800
1 500
1 200
900
600
300
0

10

300

200
100

0
10

20

30

40

50

60

70

Speed (mm/s)

Speed force diagram CASM63LS


No limitation for ball screw types (max. load
at max. speed).

100

200

300

400

500

600

700

800

Position (mm)

Radial load diagram


The radial load acts perpendicular to the
moving direction.

Lifetime diagram
CASM63BN
CASM63BF

9 000

400

10 000

50

500

8 000

600

7 000

100

6 000

700

LS
BN
BF

Stroke:
100 mm
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm
800 mm

5 000

800

4 000

500

3 000

1 000

900

2 000

1 000

Screw:
Lead screw 204 mm
Ball screw 2010 mm
Ball screw 2020 mm

Nominal load (N)

1 000

Force (N)

60f7

Linear units

23,5

34
74

36,5

Lifetime (Km)

100
200
300
400
500
600
700
800

Option1):
Motor, adapter and accessories separately delivered
Motor, adapter and foot mountings2) pre-mounted (see orientation of slots on above drawing)
1)
2)

A
M

Motor, adapter kit and accessories need to be ordered separately


Foot mountings pre-mounted on in-line version only

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12159 EN September 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Siemens motors and adapters

CASM63

CASM63
Order N
ZBE375534

In-line adapter kit for CASM63 and Siemens 1FK7034 motor*


62,4

78

Siemens motors and adapters


75

System capabilities

In order to provide you a fully integrated system, SKF combined its


actuator expertise with Siemens well-known motor knowledge.
Thanks to this partnership, SKF offers a complete linear solution, including a CASM linear unit mounted with a SIEMENS 1FK7
servomotor.
The Siemens motors 1FK7034 and 1FK7044 come with a
multipole resolver, a shaft-end with no keyway and a holding brake.
In addition, they are equipped with a DRIVE-CLiQ interface. A rotating plug adapter simplifies the connection and cable routing in all installation positions.

For more information, please visit the following sites:


Motors: www.siemens.com/motors
Frequency converters: www.siemens.com/sinamics
Automation systems: www.siemens.com/simotion
Controls: www.siemens.com/simatic
Engineering software: www.siemens.com/sizer
Support worldwide: www.siemens.de/service

CASM63LS
CASM63BN
CASM63BF

15

4M6

* Screws included

1)

Unit

Peak force

Fm1)

N
N
N

1 000
3 052
1 583

527
708
367

RMS force over full cycle. For more information, please visit www.skf.com/casm

Solution with Siemens motor 1FK7044 and compatible adapter


Order N
1FK70447AH711UH3

Dimensional drawing Siemens motor 1FK7044

Motor data

Solutions with Siemens motor 1FK7034 and compatible adapters


Order N
1FK70345AK711UH3

138

Dimensional drawing Siemens motor 1FK7034

0,63
6 000
1,3
1
1,6
6,5
0,98
36
4

96

kW
min-1
A
Nm
Nm
Nm
10-4 kgm2
mm
kg

19

1FK7034

80

Motor data
Unit

72

14

60

117

30

200

Rated power (100 K)


Rated speed
Rated current
Rated torque (100 K)
Static torque (100 K)
Peak torque
Inertia with brake
Shaft height
Weight with brake

Unit

1FK7044

kW
min-1
A
Nm
Nm
Nm
10-4 kgm2
mm
kg

1,41
4 500
4,9
3
4
12
1,41
48
8,3

40

245

Rated power (100 K)


Rated speed
Rated current
Rated torque (100 K)
Static torque (100 K)
Peak torque
Inertia with brake
Shaft height
Weight with brake

Order N
ZBE375535

In-line adapter kit for CASM63 and Siemens 1FK7044 motor*


100

70,9

Order N
ZBE375542

Parallel adapter kit for CASM63 and Siemens 1FK7034 motor*


74,1

157,3

4M6

23,5

System capabilities
Unit

Peak force

Fm1)

N
N
N

1 000
2 583
1 339

527
708
367

* Screws included

CASM63LS
CASM63BN
CASM63BF
1)

Unit

Peak force

Fm1)

N
N
N

1 000
5 400
2 800

1 000
1 745
905

RMS force over full cycle. For more information, please visit www.skf.com/casm

45

4M6

78

60 F7

96

System capabilities

CASM63LS
CASM63BN
CASM63BF
9
58,1

* Screws included

1)

RMS force over full cycle. For more information, please visit www.skf.com/casm

SKF is a registered trademark of the SKF Group


SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12195 EN October 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Accessories

CASM63

CASM63
75

Swivel flange*

Order N
ZBE37550463
For parallel version only

32

60

18

16

Accessories

6,5
11

21
51

* Screws included

Part 2

32

24

15

14

* Screws included

75

* Screws included

Order N
ZBE37551063

M16x1,5

Order N
ZBE37550363

24

21
15

Rod eye

Order N
ZBE37551163

43

64

84

20

16

Trunnion
flange kit*

* Screws included

41,5
32
16

Rod clevis

16

100

32

Order N
ZBE37550263

12

50

11

Note: The foot mounting between the linear unit and the
adapter kit increases the length of the in-line version by 5 mm

120

Flange
mounting kit*

6,5

21

92
110

64

13

50

24

Order N
ZBE37550763
For in-line version
(part 1 + part 2)

32

Part 1

Order N
ZBE37550663
For parallel version only

75

Swivel flange
with rod eye*

16

Order N
ZBE37550163
For parallel version
(2x part 1)

Foot mounting kit*

145

90

20

* Screws included

22

Order N
ZBE37550863

41

Order N
C375525NO

3,15

Proximity
sensor

29
20

LED

90

6,2

20

Trunnion
mounting kit*

22
29

20
105

* Screws included
Order N
ZBE37550963

23
11

Normally open
PNP
24 V DC
30 mA
5m

40

11

13

20

Trunnion
support pair

Switching function
Output signal
Rated voltage
Max. current
Cable length

SKF is a registered trademark of the SKF Group


20

1:2

42
65

Note: to be used with trunnion


flange kit or trunnion mounting kit

SKF Group 2011


The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 12192 EN September 2011

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CRAB 05

Rotary actuators
Dimensional drawing

86

6H8

M7x0,75

Connecting shafts

25

14

8,5

70
50

8
4

,5

SH
(b)

Rotary actuator

50

50

- 0,022 (h8)

14

(6x)
R3

-0

-0

12

8,05
21

CRAB 05

SD
8,0 +0,05
-0

0
(6

x)

32 -+0,1
0,2

20

,05

 +0

7,05 +0,05

7+0

30

+0,05
-0

- 0,05
8,0 +0,005

+0,05
-0

50

8,3
4,0

18

86

16

70

66,2

Benefits

63
42

42

 Multiple output shafts

8 h8
(a)

5,4

120 

Legend:
(a) = Blade terminal 6,3 0,8 DIN 46244
(b) = Drive cross not fixed to gear. Hardened 45HRC

Technical data

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CRAB 05

Nm
Nm
N
%

100
4,4
200
30 to 40
10 000 cycles at max. dynamic load
10 000 cycles at max. dynamic load
50
56:1 or 57:1
300
Lubricated for life
+5 to +40
max. +70

rpm

C
C

R2

26

Motor MH

Max. dynamic output torque


Max. dynamic input torque
Max. radial force
Efficiency
Service life
245 at 100 Nm
2180 at 75 Nm
Duty factor at max. dynamic force
Gear ratio
Max. input speed
Maintenance
Temperature (environment)
Temperature (product)

120 

16,5

27

Motor MD

46,5

30,8

13
24
33

21

6 h8

25

M6x0,75

M7x0,75
6 h8
5,5

M6(3x)
5

147,93

M6(3x)

 Small and compact

133,5

133,5

 Multiple motor options

Rotary actuators

CRAB 05

The Power of Knowledge Engineering


Bearings
and units

Seals

Performance diagram

Mechatronics

Speed (rpm)

Current consumption (A)

10

Recommended
working range,
motor MH

Lubrication
systems

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

Services

Recommended
working range,
CRAB 05

Ordering key

C R A B 0 5

0
25

50

75

100

Type

Torque (Nm)

Coating:
Black chromium-plated
Natural chromium-plated

Values given at 20 C and with tolerances of 20%.

B
C

Motor shaft connection:


D-hole
Hexagonal hole

D
H

Attachment/connection:
Outer connection ears (see Fig. A)
Centre connection hexagonal 32 mm (see Fig.B only option C and H)

E
S

Motors:
No motor
24 V DC for motor shaft connection D
24 V DC for motor shaft connection H

00
MD
MH

Connection shaft:
No shaft
D-shaft
Hexagonal shaft

00
SD
SH

Fig. A
86
8,5

Fig. B
70
50

14
8

8
,5

(b)

50

50

(6x)
R3

-0

-0

8,05

12
0
(6
x)

+0,05
-0

32 -+0,1
0,2
7,05 +0,05

,05

 +0

8 +0,05
-0

50
70

18

8,3
4,0

86

16

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10970 EN August 2010
Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

CRAB 17

Rotary actuators

Dimensional drawing
88

117

100
120

43,6

29

46,2
38

48,5

125
50
10

117

8,2
10,5

Rotary actuator

42,2

138

8,5

56

13,5

159,1

CRAB 17
Standard shaft design

Motor design
79,7
79,9

1 000

40
50
42H8

 Multiple motor options

Type code 2: solid/keyway

E110C
E220C

C24CN
C12CN
C90CN

28H8

42

31,3

31,3

18

28H8

19,2

Type code 4: hollow/keyway for limit switch

Type code 3: hollow/keyway

19

24,3

S - Limit switch unit

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk

Unit

CRAB 17

/s
%
N
Nm

Nm
C
kg

180
50
5 000
100
0,25
0,3 Nm
20 to +60
3

30

16

14,8 16,6
4

36,0

Type code 5: hollow/spines


Emergency manoeuvering, release on
shaft (push) hollow shaft with splines

Technical data

30

72,8

80,2

39

Max. angular working range


Max. angular speed (theoretical)
Efficiency factor
Max. axial load
Max. tilt moment
Backlash
Start torque
Temperature range
Weight

161,6

42H8

43,6

Type code 1: solid

 Small and compact

61,5

50

12

148 (C90C)

60
121,5

37

 Multiple output shafts

133 (C24C, C12C)

48

48

Benefits

A - Emergency manoeuvering,
gearhouse for hand crank

C12CE
C24CE
C90CE

Rotary actuators

CRAB 17
Seals

Performance diagrams

Mechatronics
Angular speed (deg/s)

Current consumption (A)

Angular speed (deg/s)

35

140

14

90

30

120

12

75

25

100

10

60

20

80

45

15

60

30

10

40

15

20

Lubrication
systems

Services

Current consumption (A)

105

7,5

15

22,5

30

37,5

45

52,5

60

Dynamic load (Nm) /Speed (deg/s)


0

7,5

15

22,5

30

37,5

45

Torque (Nm)

60/30
60/30
105/30
70/13
55/13

52,5

60

Torque (Nm)

Diagram for motor C12C

Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

Ordering key

0
0

CRAB 17

The Power of Knowledge Engineering


Bearings
and units

Diagram for motor C24C

38/58
38/58
53/55
40/27
34/27

Motor options
19/110
19/110
38/110
22/52
18/52

Current consumption (A)

Angular speed (deg/s)

1,8

60

0,6

50

1,6

50

0,5

40

1,4

40

0,4

30

1,2

30

0,3

20

1,0

20

0,2

10

0,8

10

0,1

0
0

10

20

30

40

50

60

70

80

Type
Emergency manoeuvre:
None
Hand crank
Release on shaft (only with standard shaft N 5)

10

15

20

25

30

35

40

45

50

A
B

Shaft design:
Solid
Solid / keyway
Hollow / keyway
Hollow / keyway for limit switch
Hollow / splines
Customer specification

Torque (Nm)

Diagram for motor E110C

Current consumption (A)

60

C12C
C24C
C90C
E110C
E220C

C R A B 1 7 X
Angular speed (deg/s)

12 V DC
24 V DC
90 V DC
120 V AC/60 Hz
230 V AC/50 Hz

55

1
2
3
4
5
6

Torque (Nm)

Limit switch:
No
Yes (fits shaft N 1, 2, 4 and 5)

Diagram for motor E220C

Motor orientation:
Rear
Upwards
Front
Downwards

R
U
F
D

Motor assembly:
Right
Left

R
L

Option for CxxC motors:


No cable
Encoder
Motor without cover
EMC filter
Straight, 2,0 m
Jack plug, 2,0 m

Gear 1
Gear 2
Gear 4

Angular speed (deg/s)


Current consumption (A)
Angular speed (deg/s)
Current consumption (A)
Angular speed (deg/s)
Current consumption (A)

E2
N
M
T2
T2P

SKF is a registered trademark of the SKF Group


SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10971 EN August 2010
Printed in Sweden on environmentally friendly paper.

Electro Mechanical Systems Limited

tel: 0118 981 7391

info@ems-ltd.com

www.ems-limited.co.uk