You are on page 1of 2

Worldwide Manufacturer of PSA Generator Systems

INTELLICONTROL
Oxymat presents the next generation of control systems with more functionalities, higher flexibility and easy integration with
other systems - all included in the intellicontrol that comes with the generator.

Main features
7 touch color screen-wide screen format

Easy to use advanced control system


Quick overview through screen with all relevant
information displayed
Advanced user access system with audit trail
Easily updated via USB or SD card
Multilanguage user interface
Multiple settings storage for varying operating conditions
Full logging of all measured values with selectable graph
for playback
Remote view and control via Ethernet available (option)
Remote operation and control via SMS available (option)
Quality logic controller multi expandable
Intellicontrol can interface to any monitoring or control
system available (option)

Built-in functionality
Operation
Automatic

Runs the system with all alarms active and pressure monitoring of product tank for stand-by function

Service mode

Runs the system with all alarms active, but no impact on the system. Do not switch into stand-by

Remote auto mode

Runs as automatic but will be stopped if local modes are activated (Automatic or Service mode)

Start/Stop via SMS

Starts as remote auto mode-option

Analogue

Pressure in product tank


Pressures in both columns-option
Purity monitoring-option

Password

As default 4 levels are implemented: guest, operator, superuser and administrator; advanced user control can be activated for strict access control and allows the system to work with individual users and levels

Alarm system

All alarms are described on the controllers display for easy and fast recovery. Alarms on air dryer and air pack can be
monitored by the controller (requires digital signals from air pack and dryer).

Drain Control

Automatic drain with double time settings-one for operation and one for system stop

Automatic start

Automatic start in auto mode after power failure; intelligent startup procedure ensures correct pressures before PSA
starts.

Smart delivery

Optimized version of our standard smart delivery function (Oxygen)

Delayed delivery

Option for delayed delivery from PSA to product tank after stand-by and system start; this ensures that purity stays
correct

Service system

A service system with pre-warnings informs the operator when it is time for the next service

Worldwide Manufacturer of PSA Generator Systems

INTELLICONTROL
Add-on features
Product name

Name

Description

26210

Alarm pack

Column pressure monitoring


Audio and visual alarm in one unit. Can be placed anywhere.Visual alarm is active whenever
an alarm is present in the system. Audio will turn on when an alarm appears but can be
turned off from for control panel.
Voltage free contacts for following alarms:
Purity alarm
Purity stop
Low pressure product
Quick stop
Low pressure columns
Alarm on air pack
Alarm on air dryer

26011

Purity control

Purges product outside valid purity range. Placed after product tank.

26012

Utility monitoring

Monitoring and alarm levels for 4 important parameters


Airpressure
Airtemperature
Dewpoint Air
Dewpoint product

26510

Flow monitoring

External flow meter connected. Reading is shown on the screen


including totalizer

26511

Flow control

External flow controller is connected. Actual flow is shown on the screen and flow can be
controlled from the screen.
Including totalizer

26430

Datalogging and remote control

Logging of all measured values to SD card (USB) remote access for view and control. Ethernet link, ModBUS, TCP/IP

26211

SMS alarm and control

Sends a text message containing alarm information to any cell phone. And start, stop reset
can be done via SMS

OM1 26101

Oxygen monitor for Oxygen generators

Range 0,1-100%.
Includes alarm function (through control)

OM1E 26121

Oxygen monitor + output

As OM1 plus 2 x analogue output 4-20mA representing pressure and purity

OM2 26102

Oxygen monitor for


Nitrogen generators

Range 0,1-25%
Includes alarm function (through control)

OM2E 26122

Oxygen monitor + output

As OM2 plus 2 x analogue output 4-20mA representing pressure and purity

OM3 26103

Oxygen monitor

Range 5-1000ppm, includes alarm function (through control)

OM3E 26123

Oxygen monitor+output

As OM3, plus 2xanalogue output 4-20mA representing pressure and purity

XCON 26600

X-controller for standard control


panels

X-CON can control up to 6 lines via remote start based on flow or pressure.
X-CON starts and stops lines according to actual product demand.

UPS 26601

UPS module

Battery backup for standard controls. 30min.

RCON 26602

Redundancy controller for 2 standard


control panels

RCON can start/stop 2 standard PSAs for redundancy purposes. The PSAs are load balanced
based on hour counter and automatically started if alarms.

FCON

Standalone flow controller

FCON can regulate the flow using a motor valve. The control needs just an
analogue signal representing the flow.

RM1 27000

Room monitoring

Oxygen detection inside container. Includes audio/visual alarm.

RM2 27001

Room monitor with battery backup.

Oxygen detection inside container. Runs independently and includes relay outputs for alarms.

FILM 27100

Manual filling station

Filling of high pressure bottles. Operator controls when filling is in progress.

BACM 27200

Manual backup

Filling of high pressure backup bottles. Operator controls when filling is in


progress. Includes alarm for low pressure and change-over system.