Professional Documents
Culture Documents
60 mm system
Selection and ordering data
Busbar holders
Fast Bus adapter shoes
Incoming supply terminals
Copper busbar
Busbar covers
Other accessories
Overview
Introduction
Technical data
Dimension drawings
Page
5/6
5/8
5/6
5/6
5/6
5/9
5/2
5/3
5/3
5/10-15
Page
5/7
5/8
5/1
Fast Bus
60 mm busbar system
for sharp-edged copper busbars
to DIN 46 433,
width 20 mm to 30 mm,
thickness 5 mm and 10 mm
Busbar holder
End and intermediate holders for
flat copper profiles
Page
Page
5/6
5/7
5/2
Page
Incoming supply terminals
5/6
Copper Busbar
5/6
Busbar covers
5/6
20 mm x 5 mm up to 30 mm x10 mm
and TT busbar
5/8
Fast Bus
Features
The Fast Bus Multi-Motor Control system is a 3-phase insulated busbar system used to reduce wire connections
and hole drilling when building control
panels. SIRIUS 3RV/3RT starter combinations built from components and Siemens circuit breakers use Fast Bus for
convenient mounting.
Benefits
Compact design
Touch safe
Modular design
Fast Bus is not new to Siemens. However, due to the narrower SIRIUS
starter components, more starters will
fit on the same run of Fast Bus.
Domestic
690V
600V
AC 1000V
N/A
Temperature stability
Up to 105 degrees C
N/A
Glass-reinforced polyamide
Same
Color
Same
Ampacity
Three single stack busbars
5 x 20 mm
3/16 x 3/4
362A
5 x 25 mm
3/16 x 1
432A
5 x 30 mm
3/16 x 1 1/8
500A
3/8 x 3/4
564A
10 x 25 mm
3/8 x 1
660A
10 x 30 mm
3/8 x 1 1/8
756A
System
mm
mm
Thermal current at
65 C
85 C
Busbar temperature
A
A
105 C
A
20 x 5
25 x 5
30 x 5
60
60
60
274
327
379
362
432
500
430
513
595
20 x 10
30 x 10
60
60
427
573
564
756
670
900
5/3
Fast Bus
Clearance in air
Creepage distance
25.4 mm (1 inch)
50.8 mm (2 inch)
25.4 mm (1 inch)
5/4
Short-circuit strength
The short-circuit strength of the
busbar system is dependent on
the spacing of the busbar holders and on the busbar crosssection.
The short-circuit strength of the
whole system is dependent on
the short-circuit strength of the
busbars and of the adapters
with circuit protection.
Applications
The 8US Fast Bus distribution
system is ideal for control panel
builders with multiple motor
applications. These applications are most common in the
material handling, automotive,
food processing, pharmaceutical and paper processing industries.
Ground busbar 6 mm x 6 mm
also available in 5 x 20 mm to
10 x 30 mm
8WC Busbar (8WC5053
shown) FBB36 Busbar (5/6)
Fast Bus
1)
MSP
Type
MSP
Size
Through
FLA range
Amps
3RV102
3RV103
3RV104
S0
S2
S3
0, 11-12
11-50
28-100
MSP
Type
Through
FLA range
Amps
3RV101
3RV102
3RV102
3RV103
3RV104
0, 11-12
0, 11-12.5
11-25
11-50
28-100
Short Circuit
Current Ratings
Fuse
Circuit Breaker
480V
575V
65kA
65kA
65kA
65kA
65kA
10kA
30kA
10kA
30kA
30kA
Fuse Selection
Calculate the maximum fuse size per
NEC430-53c.
Max Fuse Size =175% x FLC of largest motor + FLC of all other motors
(FLCs from NEC table 430-150).
Short Circuit
Current Ratings (Type E) 1)
240V
480Y/277V
600Y/347V
65kA
65kA
65kA
65kA
65kA
65kA
30kA
25kA
30kA (up to 75A)
MSP sizes S0 and S3 require additional terminal kits for type E applications. See section 1
5/5
Fast Bus
5SH3536
5SH3528
5SH3526
5SH3532
8US1922-1AC00
8US1923-3UA01
5SH3537
5SH3530
8US1923-1AA01
Description
8US1922-2UA01
8WC5
8US1948-2AA00
8US1922-1AC00
Base plate
3-pole system flat
8US19 22-2UA01
362A
362A
362A
432A
500A
564A
756A
1400A
yes
yes
yes
yes
yes
yes
yes
yes
FBB36
FBB60
8WC5053
8WC5054
8WC5055
8WC5063
8WC5065
8US19 48-2AA00
yes
yes
8US19 23-3UA01
8US19 43-3AA00
required
8US19 22-1AC00
n/a
8US19 23-1AA01
required
required
required
8US19 22-2AA00
8US19 22-2BA00
8US19 22-2DA00
required
required
5SH3536
5SH3537
80A
300A
440A
560A
560A
800A
yes
yes
yes
yes
yes
yes
5SH3538
8US19 21-1BA00
8US19 21-1AA00
FBT600F
8US19 41-2AA03
8US19 41-2AA04
yes
8US19 22-1GC00
5/6
required
for 20 mm - 30 mm x 5 mm or 10 mm 2)
also for 6 mm x 6 mm
135A
Infeed for feeder circuit (accepts all busbar sizes on this page)
3-pole terminal plate with cover
20 mm x 200 mm 16-4 AWG
3-pole terminal plate with cover
54 mm x 200 mm 10-2/0 AWG
5SH3538
81 mm x 200 mm 2 AWG-250 MCM
8US1921-1BA00 3-pole terminal plate with cover
3-pole terminal plate with cover
180 mm x 200 mm 250-600 MCM
3-pole terminal plate
154 mm x 184 mm 300-600 MCM
3-pole terminal plate
160 mm x 184 mm for flat bars up to
32 mm x 20 mm
FBT600F w/cover
8US1922-2AA00
230 mm x 1100 mm
8US1923-1AA01
UL Current UL508A
Order No.
rating
Compliance1)
180 mm x 200 mm x 90 mm
List
Pack
Price $ Units
3 pcs
3 pcs
4 pcs
1) UL 508A labeled panels require the use of components that meet the creepage and air distances of 1 air clearance and 2 creepage
distance. N/A = not applicable for given item.
2) Current rating dependent on size of busbar used. Refer to busbar selection data.
Fast Bus
Design
UL Current rating
UL SCCR1)
15 amp
20 amp
25 amp
30 amp
35 amp
40 amp
45 amp
50 amp
60 amp
70 amp
80 amp
90 amp
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
FBCB015
FBCB020
FBCB025
FBCB030
FBCB035
FBCB040
FBCB045
FBCB050
FBCB060
FBCB070
FBCB080
FBCB090
20 amp
25 amp
30 amp
35 amp
40 amp
45 amp
50 amp
60 amp
80 amp
65kA
65kA
65kA
65kA
65kA
65kA
65kA
65kA
65kA
HHED
HHED
HHED
HHED
HHED
HHED
HHED
HHED
HHED
FBCB020H
FBCB025H
FBCB030H
FBCB035H
FBCB040H
FBCB045H
FBCB050H
FBCB060H
FBCB080H
25kA
25kA
25kA
35kA
35kA
35kA
35kA
35kA
ED
ED
ED
FXD
FXD
FXD
FXD
FXD
FBCB100
FBCB110
FBCB125
FBCB150
FBCB175
FBCB200
FBCB225
FBCB250
25kA
25kA
25kA
25kA
25kA
25kA
65kA
65kA
65kA
65kA
65kA
ED
ED
ED
ED
ED
ED
FXD
FXD
FXD
FXD
FXD
FBCB050M
FBCB060M
FBCB070M
FBCB090M
FBCB100M
FBCB125M
FBCB150M
FBCB175M
FBCB200M
FBCB225M
FBCB250M
65kA
65kA
65kA
65kA
65kA
65kA
65kA
HHED
HHED
HFXD
HFXD
HFXD
HFXD
HFXD
FBCB100M-HB
FBCB125M-HB
FBCB150M-HB
FBCB175M-HB
FBCB200M-HB
FBCB225M-HB
FBCB250M-HB
List Price $
Pack
units
Circuit breakers
Feeder 3 pole/600V with Fast Bus snap on
adapter shoes. Wires from shoe to breaker on
the line side.
FBCB030
FBCB100
FBCB250M
1) UL Short Circuit Current ratings are based on 480V. Contact Siemens for 600 V ratings.
5/7
Fast Bus
AWG
mm
mm
List
Price $
per PU
Pack
units
Weight
per PU
approx
.
kg
For SIRIUS
Size S00/S0
MSPs
25
12
182
45
600
yes
8US12 51-5DM07
0.183
Contactors
+ Overload relays
25
12
182
45
600
yes
8US12 51-5DM07
0.183
25
12
182
45
600
yes
8US12 51-5DM07
0.183
Busbar adapters
25
12
182
45
600
yes
8US12 51-5DM07
0.183
+ Device holders
--
--
182
45
600
yes
8US12 50-5AM00
+ Connecting
plates
--
--
--
--
--
--
yes
8US19 98-1AA00
12
14
182
45
600
yes
8US12 51-5CM47
0.190
Reversing feeders
8US21 51-5DM07
0.158
100 units
0.100
Size S00/S0
Cage Clamp
Direct start load
feeders
Size S2
8US21 60-5AM00
MSPs
50
182
55
600
vyes
8US12 61-5FM08
0.263
Contactors
+ Overload relays
50
182
55
600
yes
8US12 61-5FM08
0.263
50
245
55
600
yes
8US12 61-5FP08
0.292
Busbar adapters
50
242
55
600
yes
8US12 61-5FP08
0.292
Busbar adapters
--
--
242
55
600
yes
8US12 60-5AM00
0.202
+ Device holders
--
--
--
242
55
600
yes
8US12 60-5AP00
+ Connecting
plates
--
--
--
--
--
--
yes
8US19 98-1AA00
70
215
72
600
yes
8US12 11-4TR00
0.470
100
--
200
72
600
yes
FBS10072
0.530
Reversing feeders
Size S3
0.243
100 units
0.100
8US12 11-4TR00
For VL UL circuit breakers
8US12 13-4AQ03
VL150 UL,
DG frame
--
150
Tubular 190
contacts
105
600
yes
8US12 13-4AQ03
1.020
VL250 UL,
FG frame
--
250
Tubular 190
contacts
105
600
yes
8US12 13-4AQ03
1.020
VL400 UL,
JG frame
--
400
Tubular 296
contacts
140
600
yes
8US12 13-4AH00
1.900
--
540
Tubular 296
contacts
140
600
yes
8US12 13-4AH00
1.900
VL400X UL,
LG frame
8US12 13-4AH00
1)
UL 508A labeled panels require the use of components that meet the
creepage and air distances of 1 air clearance and 2 creepage distance.
N/A = not applicable for given item.
5/8
Fast Bus
Length
Width
UL508A
Order No.
Compliance1)
List
Pack
Price $ Units
FBT
180 A
270 A
400 A
440 A
460 A
560 A
2)
2)
2)
2)
2)
2)
FBT166-1
FBT122-1
FBT620-1
FBT6250-1
FBT30350
FBT300600
180 A
270 A
400 A
440 A
460 A
560 A
2)
2)
2)
2)
2)
2)
FBT166-2
FBT122-2
FBT620-2
FBT6250-2
FBT30350
FBT300600
3
3
3
3
3
3
3
3
3
3
3
3
3
3
90 mm depth
90 mm depth
FBC135
8US1922-1GA02
45 mm
55 mm
70 mm
90 mm
110 mm
n/a
n/a
n/a
n/a
n/a
8US1998-7CA15
8US1998-7CA16
8US1998-4AA00
8US1998-7CA08
8US1998-7CA10
10
10
10
10
10
Connection holder
(for vertical bubar assembly)
fixes the MSP to the mounting rail3) (for SIRIUS sizes S00/S0)
n/a
8US1998-1DA00
20
Screw holder
for supplementary screw fixing of the feeder
(for SIRIUS sizes S00/S0)
n/a
8US1998-1CA00
20
Spacer
fixes the feeder to the busbar adapter
(for SIRIUS sizes S00/S0)
n/a
8US1998-1BA00
Connection wedges
for mechanical linking of adapters and switching device holders
(2 units required per combination)
n/a
FBC20
45 mm
54 mm
n/a
n/a
8US1998-8AM07
8US1998-8AA10
182 mm 10 mm
200 mm 9 mm
n/a
n/a
8US1998-2BM00
8US1998-2BJ10
n/a
n/a
5SH3532
5SH3533
n/a
n/a
n/a
5SH3528
5SH3530
5SH3531
Mounting Rail
8US1998-1BA00
FBC20
20
Plug-type terminal
(complete with supporting element for attaching to busbar adapter
and switching device holder. Spring loaded terminals.)
3 x 14 AWG (400 V) and 4 x 16AWG (250 V)
7 x 14 AWG (400 V)
91 mm
91 mm
5SH3528
Edge Profile
5SH3531
17 mm x 36 mm x 1100 mm
77 mm x 36 mm x 1100 mm
17 mm x 86 mm x 1100 mm
5/9
Fast Bus
8US19 43-3AA00
31
25
40
112
40
31
40
36 (914)
FBB60
60 (1524)
L3
01573
25
209
120
75
50
L2
L3
123
51
30
32
200
10
60
40
10
L1
NSE0_02071
FBB36
NSE0_02058
Dimension
166
185
L1
6
NSE0_02073
NSE0_02070
8US19 22-2BA00
8US19 22-2AA00
10,2
Length 1000 mm
NSE0_00721
NSE0_00720
30,5
30,5
5,2
8US19 23-1AA01
49,4
62,5
Length 1000 mm
40
5/10
60
NSE0_02072
1,5
71
78
NSE0_01607
34
31
200
8US19 22-2DA00
62,5
Fast Bus
28
32
54
36
NSE0_02060
NSE0_02074
96
156
184
60
200
194
60
94
50
21
154
88
72
100
28,7
32
28
NSE0_02053
NSE0_02059
81
88
60
148
184
194
200
60
94
50
8,8
160
88
72
100,2
FBT600F Cover
180
5/11
Fast Bus
60
20
NSE0_02051
60
10
242
182
3,4
23,7
47,4
53,8
51,7
40
60
2,
5
23,7
60,2
26,5
54,5
41
60
72
8,5
60
20
148
53
242
182
60
182
NSE0_02063
20
48
170
12
10
60
47,4
54
2,9
,4
NSE0_02068
60
182
214
200
164
60
60
NSE0_02062
20
68
148
12
60
,4
10
5/12
2,5
29,5
36
45
23,7
60,2
8,5
NSE0_02061
,5
47,4
54
23,7
60,2
8,5
Fast Bus
114,5
114,5
190
60
23
31,5
38,8
35
105
NSE0_02066
182
64
3
NSE0_02069
131,5
131,5
190
60
35,5
26,8
23
8US19 98-2BM00
14
32
42
14
35
105
NSE0_02065
60
I2_13999a
270
296
247,5
60
194
200
60
56
34
24
Infeed 5SH3538
20
28
32
45
140
NSE0_02067
55
5/13
Fast Bus
FBT166-1
FBT122-1US1
FBT6250-1
FBT620-1
7.5
10.5
17
14.5
11.5
15.5
23.5
20.5
22.5
29
36
32
25
35
55
42
5
5
5
5
10
10
12
12
FBT166-2
FBT122-2
FBT6250-2
FBT620-2
7.5
10.5
17
14.5
11.5
15.5
23.5
20.5
22.5
29
36
32
25
35
55
42
10
10
10
10
10
10
12
12
FBT300600
FBT
FBC135
8US19 22-1GA02
5/14
Fast Bus
8US19 98-4AA00
8US19 98-7CA08
29
8US19 98-7CA10
8US19 98-7CA15
8US19 98-8AM07
5SH3 528
5SH3 532
8US19 98-7CA16
29
74
90
NSE0_01599
35
27
8US19 98-1CA00
9
14
8US19 98-1BA00
8US19 98-8AA10
5SH3 531
5SH3 530
5SH3 353
8US19 98-1CA00
8US19 98-1DA00
5/15
Fast Bus
Adapter Shoe
8US1251-5DM07
Adapter Shoe
8US1251-5DM07
MSP
3RV101
MSP
3RV102
Link Module
3RA1911-1A
Link Module
3RA1921-1D
Contactor
3RT101
Contactor
3RT101
Adapter Shoe
8US1261-5FP08
Adapter Shoe
8US1251-5DM07
MSP
3RV102
MSP
3RV103
Link Module
for AC: 3RA1921-1A
for DC: 3RA1921-1B
Link Module
for AC: 3RA1931-1A
for DC: 3RA1931-1B
Contactor
3RT102
Contactor
3RT103
Adapter Shoe
8US1211-4TR00
MSP
3RV104
Link Module
for AC: 3RA1941-1A
for DC: 3RA1941-1B
Contactor
3RT104
Bracket
FBS0 070B
5/16
Fast Bus
MSP
3RV102
MSP
3RV101
Link Module
3RA1911-1A
Link Module
3RA1921-1D
(2) Contactors
3RT101
(2) Contactors
3RT101
3RA1913-2A
Wiring Kit
a Upper Wiring Module
c 2 Connecting Clips
d Mechanical Interlock
MSP
3RV102
Contactor Support
for 3RT101:
8US1250-5AM00
Contactor Support
for 3RT102:
8US1260-5AP00
(without DIN rail)
Adapter Shoe
8US1251-5DM07
Link Module
for AC: 3RA1921-1A
for DC: 3RA1921-1B
(2) Contactors
3RT102
3RA1924-2B
Mechanical Interlock
FBC20
Fast Clips
8US1998-1BA0 0
5/17
Fast Bus
MSP
3RV103
Contactor Support
8US1260-5AP00
(without DIN rail) and
with 8US1998-2BM00
Adapter Shoe
8US1261-5FP08
2 Contactors
3RT103
3RA1933-2A
Wiring Kit
a Upper Wiring Module
Link Module
Adapter Shoe
8US1211-4TR00
Mechanical Interlock
3RA1924-2B
MSP
3RV104
3RA1943-2A
Wiring Kit
a Upper Wiring Module
2 Contactors
3RT104
2 Brackets
FBS0070B
5/18
Fast Bus
3RA1210
Fast Bus Reversing
48
13 21
1)
SIEMENS
60
SIEMENS
60
159
203
159
203
2)
SIEMENS
6.5
5
SIEMENS
NSK-8167a
NSK-8166a
SIEMENS
9
45
82
98
101
27
6.5
9
5
90
1) Arcing space
2) When a front auxiliary is installed on the contactor,
add 39 mm to the depth of the contactor.
3RA1220
Fast Bus Reversing
SIEMENS
2)
185
209
183
209
2)
48
SIEMENS
NSK-8171a
13
26
23
1)
SIEMENS
SIEMENS
SIEMENS
NSK-8170a
3)
8 14
28
45
27
70
92
117
DC 127
10
8 14
100
1) Arcing space
2) Lockable in OFF position. Padlock diameter 5 mm.
3) When a front mount auxiliary is installed on the
contactor, add 49 mm to the depth of the contactor.
All dimensions shown in millimeters. For reference
purposes only. Not to be used for design or
construction purposes.
5/19
Fast Bus
3RA1230
Fast Bus Reversing
3RA1130
Fast Bus Non-reversing
1)
SIEMENS
2)
53
14
34
1)
SIEMENS
259
309
259
309
2)
SIEMENS
3)
SIEMENS
NSK-8175
NSK-8174
SIEMENS
7
10
18
17
55
18
28
68
95
10
142
DC 157
176
10
17.5
120
5/20
Fast Bus
5/21
Fast Bus
Notes
5/22