Professional Documents
Culture Documents
Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
CONSULTANTS
OB+ARCHITECTURE INC.
OWNER ARCHITECTS STRUCTURAL MECHANICAL & PLUMBING CIVIL ENGINEERS 15 W CHURCH STREET, SUITE 201
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
YOUNAN (JOHN) & RINA GHAZAL ARCHITECTURAL DYNAMICS, INC NONE A. PETER TANKEL NONE w w w . o b a r c h i t e c t u r e . c o m
THEO'S KITCHEN, INC. 2816 PICKFAIR STREET 702 DENTON RD
1593 AMARYLLIS CIRCLE ORLANDO, FL 32803 WINTER PARK, FL 32792
ORLANDO, FL 32828 PH: 407-897-5461 PH: 407-657-5585
PH: 407 282 7277 FX: 407-896-3501 FX: 407-657-5585
FX: EMAIL: ARCHSOLVE@AOL.COM CONTACT: PETER TANKEL
CL: 407 928 4754 CONTACT: JOYCE L. PHIPPS EMAIL: PTANKELPE@EMBARQMAIL.COM
EMAIL: (CONSTRUCTION DOCUMENTS
CONTACT: JOHN GHAZAL & PROJECT MANAGEMENT)
1
PLUMBING DEMOLITION PLAN,
CVR COVER, INDEX 1
LOCATION MAP A0.1 CODE INFORMATION
PD.1
P2.1
NOTES & SCHEDULE
PLUMBING RENOVATION FLOOR
PLAN & DETAILS
2
CAPTIVE AIRE - HOOD DRAWINGS
SCALE: NOT TO SCALE A0.2 LIFE SAFETY PLAN P3.1 PLUMBING RISER DIAGRAMS 3 CAPTIVE AIRE - HOOD DRAWINGS
4 CAPTIVE AIRE - HOOD DRAWINGS
ELECTRICAL
THEO'S
MD.1 HVAC DEMOLTION PLAN & NOTES
A9.1 FINISH SCHEDULE & KEY PLAN HVAC PIPING PLAN, HVAC
M2.2
DWG ORIG REV LATEST RENOVATION PLAN & NOTES
DRAWING TITLE
NO. ISSUE # ISSUE
KITCHEN
M3.1 HVAC SCHEDULES & DETAILS
E1.0 ELECTRICAL NOTES, PANELS& SYMBOLS
CRYSTAL LAKE
PLAZA
ABBREVIATIONS
ADD'L. ADDITIONAL DIA. DIAMETER JT. JOINT P.H. PHYSICALLY HANDICAPPED T.O.S. TOP OF STEEL
A.F.F. ABOVE FINISH FLOOR DIM. DIMENSION PLAS. PLASTER T. TREAD
A.F.G. ABOVE FINISH GRADE DR. DOOR K.O. KNOCK OUT TYP. TYPICAL address: 2950 CURRY FORD ROAD
P.LAM. PLASTIC LAMINATE
A.C.T. ACOUSTICAL CEILING TILE DN. DOWN PLBG. PLUMBING
ALT. ALTERNATE DS. DOWNSPOUT LAM. LAMINATED PLYWD. PLYWOOD UNFIN. UNFINISHED
ALUM. ALUMINUM DWG. DRAWING LAV. LAVATORY U.O.N. UNLESS OTHERWISE NOTED SUITE 2952
PROP. PROPERTY
ANCH. ANCHOR D.W. DRYWALL LB. POUND VERT. VERTICAL
APPROX. APPROXIMATE D.F. DRINKING FOUNTAIN L.H. LEFT HAND Q.T. QUARRY TILE VEST. VESTIBULE
ARCH. ARCHITECT L.P. LOW POINT V.C.T. VINYL COMPOSITION TILE
ORLANDO, FLORIDA 32803
EA. EACH R RADIUS
BRG. BEARING E.W.C. ELECTRIC WATER COOLER MFR. MANUFACTURER REF. REFERENCE W.C. WATER CLOSET
BM. BEAM ELEV. ELEVATION MAS. MASONRY REINF. REINFORCED, REINFORCING W.H. WATER HEATER
BTWN. BETWEEN EQ. EQUAL M.O. MASONRY OPENING REQD. REQUIRED W.P. WORK POINT project
BLK. BLOCK EXH. EXHAUST M. MATERIAL REV. REVERSE WP. WATERPROOF number: 2009 - 15
BD. BOARD EXIST. EXISTING MAX. MAXIMUM R.H. RIGHT HAND W.R. WATER RESISTANT
BTM. BOTTOM E.J. EXPANSION JOINT MECH. MECHANICAL RM. ROOM W.W.M. WELDED WIRE MESH
BLDG. BUILDING EXT. EXTERIOR MTL. METAL R.O. ROUGH OPENING W/ W/O WITH / WITHOUT
B.U.R. BUILT UP ROOF MEZZ. MEZZANINE R.T.U. ROOF TOP UNIT WD. WOOD
F.R.P. FIBERGLASS REINFORCED PANEL MIN. MINIMUM ARCHITECT SEAL / SIGNATURE
CLG. CEILING FIN. FINISH MISC. MISCELLANEOUS S.F. SQUARE FEET, FOOTAGE
C.M.U. CONCRETE MASONRY UNIT(S) F.E. FIRE EXTINGUISHER MLDG. MOULDING SCHED. SCHEDULE FLORIDA LICENSE # AR0017725
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
C.T. CERAMIC TILE FLUOR. FLUORESCENT M.R. MOISTURE RESISTANT SLT. SEALANT
C.O. CLEANOUT F.D. FLOOR DRAIN MTG. MOUNTING SEC. SECTION
COL. COLUMN FLR. FLOOR MULL. MULLION SIM. SIMILAR
CONC. CONCRETE FT. FOOT, FEET SL. SLOPE
CONST. CONSTRUCTION FTG. FOOTING NOM. NOMINAL SPEC. SPECIFICATION
C.J. CONTROL JOINT F.V. FIELD VERIFY N. NORTH SQ. SQUARE
CONT. CONTINUOUS N.I.C. NOT IN CONTRACT S.S. STAINLESS STEEL
GALV. GALVANIZED N.T.S. NOT TO SCALE STD. STANDARD
DET. DETAIL GA. GAUGE NO. NUMBER STL. STEEL
DIA. DIAMETER G.C. GENERAL CONTRACTOR GRADE STRUCT. STRUCTURAL
DIM. DIMENSION GR. GRADE O.C. ON CENTER SUSP. SUSPENDED
DR. DOOR GYP. GYPSUM OH. OVERHEAD SW. SWITCH
DN. DOWN OPG. OPENING SYS. SYSTEM
DS. DOWNSPOUT HDW. HARDWARE OPP. OPPOSITE
DWG. DRAWING HGT. HEIGHT O.D. OUTSIDE DIAMETER TEL. TELEPHONE
D.W. DRYWALL H.M. HOLLOW METAL TEMP. TEMPERED
D.F. DRINKING FOUNTAIN H.P.
HORIZ.
HIGH POINT
HORIZONTAL
P.T.
PTD.
PRESSURE TREATED
PAINTED
THRES.
T.P.D.
THRESHOLD
TOILET PAPER DISPENSER
SHEET INFORMATION
EA. EACH PNL. PANEL OR PANELING T.&G. TONGUE AND GROOVE title:
E.W.C. ELECTRIC WATER COOLER INCAN. INCANDESCENT PART. PARTITION T.&B. TOP AND BOTTOM
ELEV.
EQ.
EQUIP.
ELEVATION
EQUAL
EQUIPMENT
I.D.
INSUL.
INT.
INSIDE DIAMETER
INSULATION
INTERIOR
T.O.F.
T.O. MAS.
TOP OF FOOTING
TOP OF MASONRY
COVER
drawn:
SHEET JLP
reviewed:
OB / RG
date:
lman:
1 SITE PLAN
SCALE: NOT TO SCALE
sheet setup:
sheet
number:
CVR
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
GENERAL CONSTRUCTION NOTES CODE INFORMATION, GENERAL CODE INFORMATION RESTAURANT - INTERIOR ALTERATION
1. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO THE PREPARATION OF HIS BID AND THOROUGHLY FAMILIARIZE CODE REQUIREMENTS: IT IS THE INTENT THAT ALL WORK SHALL CONFORM TO THE ADOPTED
HIMSELF WITH THE CONDITIONS OF THE CONSTRUCTION AREA AND THE WORK REQUIRED TO PERFORM THE WORK OF THIS CODES, STANDARDS AND RULES OF THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION.
OCCUPANCY CLASSIFICATION : FIRE SEPARATIONS :
CONTRACT.
ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS IN ACCORDANCE WITH THE
REQUIREMENTS OF ALL THE FOLLOWING WHERE APPLICABLE: EXISTING 1-HOUR WALLS BETWEEN ADJACENT TENANTS.
2. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF THE SOILS REPORT. OBTAIN FROM THE NEW BUILDING: 2007 FLORIDA BUILDING CODE : ASSEMBLY OB+ARCHITECTURE INC.
GROUP A-2 15 W CHURCH STREET, SUITE 201
OWNER THE CURRENT COPY OF THE SOILS INVESTIGATION REPORT. ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
SECTION 303
(A) GOVERNING MUNICIPAL AND REGULATORY AGENCIES w w w . o b a r c h i t e c t u r e . c o m
3. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES BY THE GENERAL CONTRACTOR AND ALL AREAS SHALL BE LEFT IN (B) LOCAL, STATE AND FEDERAL BODIES
A CLEAN CONDITION AT ALL TIMES DURING CONSTRUCTION. (C) 2007 FLORIDA BUILDING CODE with 2009 SUPPLEMENT
BUILDING AREA : OCCUPANT LOAD :
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES RELATED TO THE ISSUANCE OF PERMITS, INSPECTIONS AND
CERTIFICATES NECESSARY FOR THE EXECUTION AND COMPLETION OF THE WORK, AND THE OCCUPANCY OF THE WORK. ALLOWED, PER 2007 FLORIDA BUILDING CODE, TABLE 503 :
IT IS UNDERSTOOD THAT ALL INTENDED WORK IS SUBJECT TO REVIEW AND INTERPRETATION BY
THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION. IN NO CASE SHALL WORK BE OCCUPANCY PER 2007 FLORIDA BUILDING CODE, TABLE 1004.1.1 & NFPA 101 TABLE 7.3.1.2
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AND TO PROTECT THEM TENANT OCCUPANCY GROUP A-2, TYPE II-B, SPRINKLERED = 9,500 S.F. PER FLOOR ALLOWED,
PERFORMED WITHOUT THE REVIEW AND WRITTEN APPROVAL OF SAID AUTHORITY.
FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER + 2 STORIES ALLOWED TOTAL LOAD = 48 (SEE TABLE THIS SHEET)
PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. ALL FINAL CONNECTIONS
FROM THE BUILDING TO EXISTING UTILITIES SHALL BE BY THIS CONTRACTOR. ACTUAL TENANT SQUARE FOOTAGE: 1,400 SF
APPLICABLE CODES :
EGRESS REQUIREMENTS :
6. AS REQUIRED, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/DESIGNER OF ALL CONFLICTS AND
DISCREPANCIES THAT AFFECT THE WORK PRIOR TO PROCEEDING WITH SAID WORK. CITY OF ORLANDO, FLORIDA BUILDING TYPE :
2007 FLORIDA BUILDING CODE, CHAPTER 6 :
7. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS WILL GOVERN. LARGE-SCALE DRAWINGS SHALL GOVERN OVER FLORIDA BUILDING CODE 2007 EDITION with 2009 SUPPLEMENT FOR THE FOLLOWING OCCUPANCY GROUP : A-2, ASSEMBLY
DISCIPLINES: FBC NFPA 101
SMALLER-SCALED DRAWINGS. CONTACT ARCHITECT/DESIGNER TO CONFIRM ALL DISCREPANCIES. TYPE TWO-B (II-B), UNPROTECTED, SPRINKLERED
REVISION / SUBMISSION
8. CONFIRM ALL HORIZONTAL DIMENSIONS WITH PLANS AND IN FIELD PRIOR TO FABRICATION AND/OR CONSTRUCTION. • BUILDING MATERIALS :
• PLUMBING • CMU EXTERIOR WALLS 2 EXITS REQUIRED PER FLOOR PER 1018.1 2 2
9. DIMENSIONS ARE FACE TO FACE OF MASONRY WALLS AND TO FINISH FACE OF STUD PARTITIONS. DIMENSIONS ON PLANS • MECHANICAL • STEEL ROOF FRAMING (BASED ON OCCUPANT LOAD FOR 1-500 OCCUPANTS) issued: PERMIT 20 JAN 2010
INDICATE NOMINAL WIDTH UNLESS OTHERWISE INDICATED. • FUEL & GAS • BUILT-UP ROOF
• FLORIDA ACCESSIBILITY FOR BUILDING CONSTRUCTION • CMU & METAL STUD INTERIOR PARTITIONS 1 EXIT PERMITTED FOR TENANT WITH MAXIMUM 50 1 1
OCCUPANTS PER FBC AND 'X' OCCUPANTS PER NFPA revised:
10. THE ARCHITECT/DESIGNER SHALL NOT BE HELD RESPONSIBLE FOR WORK PERFORMED NOT IN ACCORDANCE WITH • STATE OF FLORIDA MODEL ENERGY EFFICIENCY
THESE DOCUMENTS NOR FOR MISINTERPRETATION OF THE DRAWINGS, NOR FOR UNSATISFACTORY WORK BY CONTRACTOR. FIRE RESISTANCE RATINGS FROM TABLE 601
FLORIDA FIRE PREVENTION CODE 2007 EDITION MAX. EXIT ACCESS TRAVEL DISTANCE (SPRINKLERED) 250' 250'
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SECURITY OF THE SITE AS REQUIRED IN THE CONTRACT FIRE RESISTANCE RATINGS REQUIREMENTS PER FBC TABLE 601 :
DOCUMENTS. NFPA 101 2006 EDITION LIFE SAFETY CODE with FLORIDA AMENDMENTS MAXIMUM DEAD END CORRIDOR (SPRINKLERED) 20' 20'
BUILDING ELEMENT TYPE II-B
12. THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS NFPA 1 UNIFORM FIRE CODE 2006 EDITION with FLORIDA AMENDMENTS MAXIMUM COMMON PATH OF TRAVEL (SPRINKLERED) 75' 75'
AND WORKERS AS REQUIRED BY GENERAL CONDITIONS AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. STRUCTURAL FRAME
ENGINEERING STANDARDS MANUAL INCLUDING COLUMNS, GIRDERS, TRUSSES 0 MINIMUM EGRESS DOOR CLEAR WIDTH 32" 32"
13. DO NOT OBSTRUCT STREETS, SIDEWALKS, ALLEYS OR OTHER RIGHT-OF-WAYS WITHOUT FIRST OBTAINING PROPER
PERMITS. ORLANDO URBAN STORMWATER MANUAL BEARING WALLS MINIMUM AISLE 36"
EXTERIOR 0
14. ALL FIRE RATED CONSTRUCTION SHALL CONFORM WITH U.L. TESTED STANDARDS AND/OR LOCAL REQUIREMENTS. FLORIDA DEPARTMENT of TRANSPORTATION MANUAL on UNIFORM TRAFFIC CONTROL DEVICE INTERIOR 0 MINIMUM CORRIDOR 44"
STANDARDS
15. CONTRACTOR TO PROVIDE & INSTALL WALL-MOUNTED, 5 LB, 2A:10B:C MULTI-PURPOSE FIRE EXTINGUISHERS AS NONBEARING WALLS AND PARTITIONS SEE TABLE 602 MINIMUM STAIR WIDTH (N/A) 44" 44"
FLORIDA DEPARTMENT of TRANSPORTATION ROADWAY and TRAFFIC DESIGN STANDARDS
REQUIRED BY LOCAL FIRE MARSHAL. COORDINATE LOCATIONS/PLACEMENTS WITH FIRE MARSHAL. INSTALL QUANTITY AS EXTERIOR
REQUIRED SO AS NOT TO EXCEED 75' OF TRAVEL TO AN EXTINGUISHER. EGRESS WIDTH PER PERSON (HORIZONTAL EGRESS) .2" .2"
CITY OF ORLANDO STANDARD SPECIFICATIONS for ROAD, BRIDGE and UTILITY CONSTRUCTION
(1991) NONBEARING WALLS AND PARTITIONS PROJECT INFORMATION
16. ALL PENETRATIONS THRU FIRE RATED CONSTRUCTION SHALL COMPLY WITH UL & ALL APPLICABLE CODES & INTERIOR 0 EGRESS WIDTH PER PERSON (VERTICAL EGRESS) (N/A) .3" .3"
ORDINANCE. NATIONAL ELECTRIC CODE 2005 EDITION
FLOOR CONSTRUCTION
NOTE : SEE LIFE SAFETY PLANS FOR ACTUAL EXIT WIDTHS
17. SEAL/ CAULK PERIMETER OF RATED WALLS AND PENETRATIONS OF RATED WALLS IN ACCORDANCE WITH APPLICABLE FLORIDA STATUTES INCLUDING SUPPORTING BEAMS AND JOISTS 0
SEE LIFE SAFETY PLANS FOR ACTUAL EGRESS PATHS & DISTANCES
UL DESIGNS, AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.
FLORIDA ADMINISTRATIVE CODE ROOF CONSTRUCTION
18. ALL ELECTRICAL AND MECHANICAL INFORMATION CONTAINED IN THESE DRAWINGS IS SOLELY FOR THE PURPOSE OF INCLUDING SUPPORTING BEAMS AND JOISTS 0
COORDINATION OF THE ARCHITECT/DESIGNER'S WORK. ORLANDO CITY CODE
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE
19. UNLESS OTHERWISE NOTED OR DETAILED, PIPE CHASE WALLS WITH A THICKNESS GREATER THAN 4" SHALL BE SEPARATION DISTANCE - FBC TABLE 602 WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY ACCESSIBLE
OCCUPANT LOAD SPACE THEN AT LEAST TWO ACCESSIBLE MEANS OF EGRESS MUST BE PROVIDED.
CONSTRUCTED OF 2-1/2" METAL STUDS WITH ONE LAYER 5/8" GYPSUM BOARD EACH SIDE OF CHASE WALL. PROVIDE
METAL OR GYPSUM BOARD CROSS BRACES AS REQUIRED TO ADEQUATELY BRACE THE WALL AND TO MAINTAIN THE RATING
OF THE PARTITION. HOLD CHASE WALLS TO MINIMUM DIMENSIONS.
FIRE SEPARATION DISTANCE (FEET)
> 30
TYPE OF CONSTRUCTION
II-B
GROUP A-2
0
DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHEN SERVING 50 0R
M0RE OCCUPANTS. MEANS OF EGRESS SHALL BE ILLUMINATED TO AT LEAST ONE
FOOT-CANDLE, MEASURED AT THE FLOOR.
THEO'S
20. VERTICAL PIPING LOCATED WITHIN THE STUD SPACE OF PARTITIONS SHALL BE FULLY ENCLOSED WITH A FULL
THICKNESS OF GYPSUM BOARD ON EACH SIDE OF THE STUD. PROVIDE 6" STUDS WHERE REQUIRED TO CONCEAL PIPING
AND OTHER ITEMS OCCURRING WITHIN PARTITIONS.
OCCUPANT LOAD PER TABLE 1004.1.2
24. METAL STUD GAUGES FOR INTERIOR PARTITIONS SHALL BE AS RECOMMENDED BY AND/OR REQUIRED BY THE STUD • ONE-STORY
MANUFACTURER FOR EACH SPECIFIC CONDITION. • ± 18'-0" AT HIGHEST PARAPET @ TENANT SPACE
SUITE 2952
PLUMBING FIXTURE REQUIREMENTS EXISTING HAIR SALON - GROUP 'B'
ORLANDO, FLORIDA 32803
OCCUPANTS LOAD PER TABLE 403.1 (2007 FBC PLUMBING CODE) GROUP A-2, ASSEMBLY THEO'S KITCHEN (1400 SF)
project
REQUIRED FIXTURES EXISTING RESTAURANT - GROUP 'A-2' number: 2009 - 15
DRINKING
• SEE OCCUPANT LOAD ABOVE FOR TOTAL 48 WATER CLOSETS LAVATORIES SHOWERS OTHER NOTES
FOUNTAINS
OCCUPANTS DESIGN BASIS ARCHITECT SEAL / SIGNATURE
• 24 MEN & 24 WOMEN ASSUMED WINN-DIXIE
MEN WOMEN MEN WOMEN MEN WOMEN FLORIDA LICENSE # AR0017725
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
SHEET INFORMATION
DRAWING SYMBOL LEGEND title:
A0.1
number:
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
1
SCALE: 1/4" = 1'-0"
sheet
LIFE SAFETY FLOOR PLAN
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
LIFE SAFETY
THEOS-LIFE
PS-A2.2
OB / RG
FLOOR PLAN
JLP
A0.2
2950 CURRY FORD ROAD
2009 - 15
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
NORTH
1
2
sheet SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
EXISTING FLOOR PLAN
DEMOLITION FLOOR PLAN
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
THEOS-DEMO
PS-A2.2
FLOOR PLANS
EXISTING &
OB / RG
DEMOLITION
JLP
2950 CURRY FORD ROAD
2009 - 15
8 FEB 2010
AD.1
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
NORTH
1
SCALE: 1/4" = 1'-0"
2
SCALE: 1/4" = 1'-0"
EXISTING REFLECTED CEILING PLAN
DEMOLITION REFLECTED CEILING PLAN
sheet
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
THEOS-DEMO
CEILING PLANS
PS-A2.2
EXISTING &
OB / RG
DEMOLITION
JLP
AD.2
2950 CURRY FORD ROAD
2009 - 15
8 FEB 2010
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
1
SCALE: 1/4" = 1'-0"
sheetEXISTING / DEMO UTILITIES FLOOR PLAN
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
THEOS-DEMO
UTILITIES PLANS
PS-A2.2
EXISTING &
OB / RG
DEMOLITION
JLP
2950 CURRY FORD ROAD
AD.3
ORLANDO, FLORIDA 32803
SUITE 2952
2009 - 15
8 FEB 2010
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
sheet
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
THEOS-DEMO
UTILITIES PLANS
PS-A2.2
EXISTING &
AD.4
OB / RG
DEMOLITION
JLP
2950 CURRY FORD ROAD
2009 - 15
8 FEB 2010
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
NORTH
1
SCALE: 1/4" = 1'-0"
2
SCALE: 1/4" = 1'-0"
sheet
NEW EQUIPMENT FLOOR PLAN
NEW ANNOTATED FLOOR PLAN
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
20 JAN 2010
THEOS-DEMO
ANNOTATED
PS-A2.2
FLOOR PLANS
EQUIPMENT &
OB / RG
JLP
2950 CURRY FORD ROAD
2009 - 15
8 FEB 2010
A2.1
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
1
SCALE: 1/4" = 1'-0"
ROOF PLAN
1
sheet
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
COMMENTS
REVISION #1
85 WEST
TRC & BUILDING DEPARTMENT
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
OB+ARCHITECTURE INC. 33 EAST PINE STREET
MICHIGAN STREET
THEOS-ROOF
PS-A2.4
31 AUG 2009
OB / RG
ROOF PLAN
JLP
A2.2
ORLANDO, FLORIDA
85 WEST MICHIGAN STREET
2009 - 15
32806
25 SEPT 2009
31 AUG 2009
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
OB+ARCHITECTURE INC.
15 W CHURCH STREET, SUITE 201
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
w w w . o b a r c h i t e c t u r e . c o m
ACOUSTICAL CEILING
TILE - SEE A6.1 & A9.1 TOP BRACE @ PARTITION TOP BRACE @ PARTITION
1'-0"
FOR FINISHES WITH METAL STUD KICKERS WITH METAL STUD KICKERS
@ 8'-0" OC TO STRUCTURE @ 8'-0" OC TO STRUCTURE
3-5/8", 20 GA METAL STUD ABOVE WHERE NECESSARY 3-5/8", 20 GA METAL STUD ABOVE WHERE NECESSARY
FRAMING @ 24" OC MAX FRAMING @ 24" OC MAX
1-1/2", 25 GA METAL STUD SCREW BOTH SIDES OF 1-1/2", 25 GA METAL STUD SCREW BOTH SIDES OF REVISION / SUBMISSION
CROSS-BRACING @ 48" OC MAX TRACK TO EACH VERTICAL CROSS-BRACING @ 48" OC MAX TRACK TO EACH VERTICAL
STUD WITH MIN (1) #8 STUD WITH MIN (1) #8
SHEET METAL SCREWS SHEET METAL SCREWS issued: PERMIT 8 FEB 2010
revised:
1'-0"
1'-0"
1
2" GYP BOARD CEILING
PROJECT INFORMATION
NOTE; PROVIDE 58" PLYWOOD
BLOCKING WHERE NECESSARY
AT SHELVING OR WALL-HUNG NOTE; PROVIDE 58" PLYWOOD NOTE; PROVIDE 58" PLYWOOD
EQUIPMENT BLOCKING WHERE NECESSARY BLOCKING WHERE NECESSARY
AT SHELVING OR WALL-HUNG AT SHELVING OR WALL-HUNG
ENSURE THAT HOOD CLEARANCE IS 18" FROM ANY COMBUSTIBLE EQUIPMENT EQUIPMENT
NOTE; PROVIDE 58" PLYWOOD
MATERIALS, PROVIDE STAINLESS STEEL 3 SIDES OF HOOD CONSTRUCTION
SOUND BATT INSULATION BLOCKING WHERE NECESSARY SOUND BATT INSULATION
THEO'S
AT SHELVING OR WALL-HUNG
NOTE: PROVIDE 58" PLYWOOD BLOCKING WHERE NECESSARY AT SHELVING EQUIPMENT
OR WALL-HUNG EQUIPMENT 3-5/8", 25-GAUGE METAL 3-5/8", 25-GAUGE METAL
9'-0" OR 11'-0"
9'-0" OR 11'-0"
5 5 5
8" GYP BOARD 8" GYP BOARD 8" GYP BOARD
9'-0"
9'-0"
9'-0"
9'-0"
EXISTING ONE HOUR WALL
TO BOTTOM OF ROOF DECK
5
8" DUROCK BEHIND TILE 5
8" DUROCK BEHIND TILE
WAINSCOT TO 5'-0" AFF WAINSCOT TO 5'-0" AFF,
SEE FINISH SCHEDULE FOR
SOUND BATT INSULATION LOCATIONS OF SPECIFIC
FINISHES
address: 2950 CURRY FORD ROAD
5/8" DUROCK
5/8" DUROCK
5/8" DUROCK
CERAMIC TILE OVER CERAMIC TILE OVER CERAMIC TILE OVER
1'-4"
1'-4"
1'-4"
1'-4"
CONCRETE SLAB, SEE FINISH CONCRETE SLAB,
CONCRETE SEESEE
SLAB, FINISH
FINISH CONCRETE SLAB, SEE FINISH CONCRETE SLAB, SEE FINISH
SCHEDULE SCHEDULE
SCHEDULE SCHEDULE SCHEDULE
project
number: 2009 - 15
BASE, SEE FINISH SCHEDULE BASE, SEE FINISH SCHEDULE BASE, SEE FINISH SCHEDULE BASE, SEE FINISH SCHEDULE
TRAKFAST PIN @ 24" O.C., TRACK TRAKFAST PIN @ 24" O.C., TRACK TRAKFAST PIN @ 24" O.C., TRACK TRAKFAST PIN @ 24" O.C., TRACK TRAKFAST PIN @ 24" O.C., TRACK
TO SLAB. SCREW BOTH SIDES OF TO SLAB. SCREW BOTH SIDES OF TO SLAB. SCREW BOTH SIDES OF TO SLAB. SCREW BOTH SIDES OF TO SLAB. SCREW BOTH SIDES OF
TRACK TO EACH VERTICAL STUD TRACK TO EACH VERTICAL STUD TRACK TO EACH VERTICAL STUD TRACK TO EACH VERTICAL STUD TRACK TO EACH VERTICAL STUD
WITH MIN (1) #8 SHEET METAL WITH MIN (1) #8 SHEET METAL WITH MIN (1) #8 SHEET METAL WITH MIN (1) #8 SHEET METAL WITH MIN (1) #8 SHEET METAL
SCREW SCREW SCREW SCREW SCREW
SHEET INFORMATION
title:
P1 P2 P3 P4 P5 SECTIONS
drawn:
JLP
reviewed:
OB / RG
INTERIOR PARTITIONS
date:
20 JAN 2010
sheet setup:
sheet
number:
A3.1
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
NORTH
1
SCALE: 1/4" = 1'-0"
sheet
NEW REFLECTED CEILING PLAN
date:
title:
lman:
drawn:
issued:
project
revised:
address:
number:
number:
reviewed:
sheet setup:
PERMIT
OB+ARCHITECTURE INC.
PLAZA
15 W CHURCH STREET, SUITE 201
THEO'S
REVISION / SUBMISSION
PROJECT INFORMATION
SHEET INFORMATION
CRYSTAL LAKE
w w w . o b a r c h i t e c t u r e . c o m
ORLANDO, FL 32801 PH: 407.650.3735 FX: 407. 650.3736
20 JAN 2010
THEOS-DEMO
PS-A2.2
NEW REFLECTED
OB / RG
CEILING PLAN
JLP
2950 CURRY FORD ROAD
2009 - 15
8 FEB 2010
A6.1
ROOM DOOR DOOR FRAMES DETAILS - SEE A8.1 HARDWARE DOOR PROTECTION FIRE
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
SC HOLLOW
MEN 103 D103 3'-0" x 6'-8" X 1-3 4" F WOOD STAIN 1 METAL PAINT 1 1 - #3 MARBLE - - - RESTROOM DOOR, 3
4" DOOR UNDERCUT
SC HOLLOW
WOMEN 102 D102A 2'-8" x 6'-8" X 1-3 4" F WOOD STAIN 1 METAL PAINT 1 1 - #3 MARBLE - - - RESTROOM DOOR, 3
4" DOOR UNDERCUT
SC HOLLOW
STORAGE 106 D106 3'-0" x 6'-8" X 1-3 4" F WOOD STAIN 1 METAL PAINT 1 1 - #4 - - - - 3
4" DOOR UNDERCUT
SC HOLLOW MFR - -
KITCHEN 107 D107A 2'-8" x 6'-8" X 1-3/4" E WOOD STAIN 1 METAL PAINT 2 2 - - ACRYLIC ELIASON DOOR
w w w . o b a r c h i t e c t u r e . c o m
DOOR & HARDWARE 1. ALL DOORS TO BE PROVIDED WITH HARDWARE (LEVER TYPE) HAVING A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT
ACCESSIBILITY PINCHING OR TWISTING OF THE WRIST TO OPERATE; IN ACCORDANCE WITH FLORIDA STATUTES CHAPTER 553, PART V, FLORIDA ACCESSIBILITY CODE 4.13.9
2. ALL DOORS SHALL HAVE SAME ELEVATION WITH NO MORE THAN 1/4" DIFFERENCE ON EITHER SIDE OF THRESHOLD.
NOTES 3. ALL DOORS AND WINDOWS SHALL HAVE CAULK ON INTERIOR PERIMETER AND SEALANT ON EXTERIOR PERIMETER.
2"
REINFORCED
6"
PER SCHEDULE
PER SCHEDULE
PER SCHEDULE
REVISION / SUBMISSION
INTERIOR JAMB DETAIL
6'-10"
1 issued: PERMIT 8 FEB 2010
2'-0"
REINFORCED revised:
CAULK, CONT.
HOLLOW METAL FRAME
REINFORCED AT HARDWARE HARDWARE SCHEDULE HARDWARE SPECIFICATIONS PROJECT INFORMATION
LOCATION
(DESIGN BASIS)
(SEE PLANS FOR
4"
53
2 PANIC OR FIRE EXIT 1-1/2 PAIR BUTTS 1-1/2 PAIR BUTTS HINGES, EXTERIOR DOORS HAGER BB1199 NRP 4.5x4.5 630
HARDWARE SETS 1 STORAGE LOCKSET 1 PASSAGE LOCKSET
#1 #4 1 OVERHEAD STOP #7 1 WALL STOP or OVERHEAD STOP CLOSER LCN 1460 SERIES SNB 689
1 CLOSER
THEO'S
BALANCE OF HARDWARE BY 1 MOP PLATE
SILENCERS SILENCERS SCHLAGE RHODES SERIES 626
MANUFACTURER LOCKSET / LATCHSET FLUSH
RAIN DRIP
PEMKO 2005AV
PEMKO 346D
1/2" MAX.
y = 48 MIN.
60" MINIMUM
18" MINIMUM,
PULL SIDE
PUSH SIDE
24" PREFERRED ARCHITECT SEAL / SIGNATURE
FLORIDA LICENSE # AR0017725
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.
1/4" MAX.
B HINGE SIDE APPROACHES
54" MINIMUM
PUSH SIDE
PULL SIDE
PUSH SIDE
PULL SIDE
SHEET INFORMATION
y
y
x
NOTES title:
y = 42" MIN.
date:
48" MINIMUM
20 JAN 2010
24" MIN. x
24" MINIMUM
PUSH SIDE
PULL SIDE
x
lman:
PS-A9.1
sheet setup:
THEO-SCHEDULES
NOTE: y = 48" IN MINIMUM IF THE DOOR
NOTE: y = 54 IN MINIMUM IF THE DOOR sheet
HAS A CLOSER. number:
HAS A CLOSER.
A8.1
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
w w w . o b a r c h i t e c t u r e . c o m
WOMEN 104 CT - 1 CTB - 1 PGB 9' - 0" - -
COOLER 105 CT - 1 CTB - 1 MFR MFR - -
STORAGE 106 CT - 1 CTB - 1 ACT - 1 11'-0" - -
KITCHEN 107 CT - 1 CTB - 1 ACT - 1 11'-0" - - KITCHEN
107
ROOM FINISH LEGEND NOTE : NOT ALL FINISHES LISTED ARE USED THIS PROJECT
TABLE 803.5 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
k
COOLER
DESIGNATION DESCRIPTION MANUFACTURER'S SPECIFICATION 105
SPRINKLERED l NONSPRINKLERED
CT-1 QUARRY or CERAMIC TILE TBD - SELECTION BY OWNER GROUP Exit enclosures and Rooms and c Exit enclosures and Rooms and c
exit passageways a,b Corridors Enclosed Spaces exit passageways a,b Corridors Enclosed Spaces REVISION / SUBMISSION
CPT-1 CARPET TBD A-1 & A-2 B B C A Ad Be
8 FEB 2010
R-1 RUBBER SHEET FLOORING TBD A-3,f A-4, A-5 B B C A Ad C issued: PERMIT
FLOOR FINISHES
R-2 C C C B B C
VB-2 VINYL COVED BASE @ VCT TBD R-3 C C C C C C
S C C C B B C
ACT-1 24" x 24" ACOUSTICAL MANUFACTURER: USG U No restrictions No restrictions
CEILING TILE MATERIAL: MINERAL FIBER
FINISH: ECLIPSE CLIMA-PLUS
SIZE: 24" x 24" For SI: 1 inch = 25.4 mm, 1 square foot = 0.0929 m².
CORR
PROJECT INFORMATION
SUSPENSION SYSTEM: DONN DX / DXL
COLOR: WHITE a. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade 1023
lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section
ACT-2 24" x 24" VINYL-COATED MANUFACTURER: USG 803.4.1.
ACOUSTICAL CEILING TILE SHEETROCK BRAND CLIMAPLUS LAY-IN PANELS
FINISH: VINYL FACE AND BACK
SIZE: 24" x 24" b. In exit enclosures of buildings less than three stories in height of other than Group I-3, Class B interior finish for nonsprinklered buildings and Class
SUSPENSION SYSTEM: DONN BRAND ZXLA C interior finish for sprinklered buildings shall be permitted. MEN
COLOR: WHITE 103
c. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire-resistance rating is required for
CEILING
structural elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered
THEO'S
PGB PAINTED GYPSUM BOARD TBD enclosing spaces and the rooms or spaces on both sides shall be considered one. In determining the applicable requirements for rooms and enclosed
spaces, the specific occupancy thereof shall be the governing factor regardless of the group classification of the building or structure.
OTD OPEN TO DECK TBD
d. Lobby areas in Group A-1, A-2 and A-3 occupancies shall not be less than Class B materials.
f. For places of religious worship, wood used for ornamental purposes, trusses, paneling or chancel furnishing shall be permitted.
SERVING
101
KITCHEN
P-2 EPOXY PAINT - WALL TBD
g. Class B material is required where the building exceeds two stories.
P-3 PAINT - WALL TBD h. Class C interior finish materials shall be permitted in administrative spaces.
P-4 DOOR & WINDOW FRAMES TBD i. Class C interior finish materials shall be permitted in rooms with a capacity of four persons or less. CRYSTAL LAKE
PAINT
S-1 DOOR STAIN TBD j. Class B materials shall be permitted as wainscoting extending not more than 48 inches above the finished floor in corridors. PLAZA
k. Finish materials as provided for in other sections of this code.
PGB-1 GYP BOARD, PAINTED TBD
l. Applies when the exit enclosures, exit passageways, corridors or rooms and enclosed spaces are protected by a sprinkler system installed in
MRGB
MOISTURE-RESISTANT TBD accordance with Section 903.3.1.1 or 903.3.1.2.
GYP BOARD
SEE INTERIOR PARTITION SECTIONS & INTERIOR ELEVATIONS FOR
CTW CERAMIC TILE WAINSCOT SIZES & PATTERNS
WALL FINISHES
MIRROR TOWEL
PAPER TOWEL HOOK
DISPENSER TOILET SEAT SOAP DISH WATER COOLER
SHEET INFORMATION
SOAP COVER
GRAB BAR SANITARY title:
DISPENSER DISPENSER
TOILET PAPER NAPKIN LAVATORY
DISPENSER DISPOSAL
FINISH SCHEDULE
& AREA TAKEOFFS
FINISH FLOOR drawn:
JLP
reviewed:
HANDICAPPED INSTALLATION: OB / RG
EXPOSED HOT WATER &
date:
DRAIN PIPES TO BE INSULATED 20 JAN 2010
(SEE PLUMBING FIXTURE
lman:
SCHEDULE)
PS-A9.1
A9.1