You are on page 1of 6

2GIG-TAKE-KIT1

HARDWIRE CONVERSION KIT


INSTALL INSTRUCTIONS
The2GIGHardwireConversionKit(2GIGTAKEKIT1)providesinstallers
withaneasymethodfortakingoveraprewiredsecurityalarmsystem
andconvertingtheexistinghardwiredzonestowirelesszones.
Toensureoptimalperformancewiththe2GIGControlPanel,thekit
providesanABSPlasticenclosure(UL94:V0)toprotectthekits
components.Theenclosurehousesuptothree(3)SuperSwitch
TakeoverModules(2GIGTAKE345)andthePowerSupplyBoardwith
backupbatterychargingcircuit.Italsoincludesaspaceforplacinga
suitablebackupbattery.
Thekitincludesone(1)SuperSwitchTakeoverModule(Wireless
TakeoverofanAlarmSystem.USPatentNo.8,638,218).Youcanalso
installtwo(2)additionalmodules,whichpermitsyoutoconvertupto24
prewiredsecurityzonestowirelesszones(eachmoduleconvertseight
(8)zones).
IMPORTANT: TheSuperSwitchcannotbeusedtomonitorCarbon

Monoxide(CO)orFiredetectionzonesandtheHardwire
ConversionKitisintendedforindooruseonly.
Figure 1 Hardwire Conversion Kit

Box Contents
Verifythatthepackageincludes:
1SuperSwitchTakeoverModule(2GIGTAKE345)
1PlasticBracket
2PhillipsHeadScrewsforPlasticBracket
112/24VDCPowerSupplyBoard
116.5VAC50VAGroundedPluginTransformer
1ABSPlasticWallMountEnclosure
1RemovableEnclosureDoor
4DrywallAnchorsandPhillipsHeadScrewsformounting
theenclosure.
1DoublesidedAdhesiveTapeforSuperSwitchPlastic
Bracket
32.5inch(6.35cm)DoubleStickFoamStripsforPower
SupplyBoard
12.5inch(6.35cm)DoubleStickFoamStripsforPlugin
Transformer

Additional Equipment
AdditionalequipmentcanbepurchasedtoenhancetheHardwire
ConversionKit:
BackupBattery(Required).Youmustinstalla12V,1.4AH
RechargeableSealedLeadAcidBattery(orbetter).
LinearH208(Optional).Thiskitisrecommendedforlockingthe
plasticwallmountenclosurewithakeyforadditionalsecurity.
Fordetails,visit:http://www.linearcorp.com/
product_detail.php?productId=317

Mounting the Enclosure to the Wall


Whencompletingthestepsbelow,refertoFigure2 "Mountingthe
EnclosuretotheWall"onpage2.
Tomounttheenclosuretothewall:
1 ChoosealocationwithinRFrangeoftheControlPanel.Beforeyou
begin,ensurethemountinglocationisfreeofelectricalwiresand
plumbingsystemsbeforedrillingintothewall.
2 Temporarilyremovetheenclosuredoorbyliftingthecoverupand
pushingitbackuntilthedoorshingepinsdisengage.
3 Usingthefour(4)keyholeslotsasatemplate,markthelocationof
thefour(4)mountingholesatthetopofthekeyholeslots.Ensure
thattheenclosurewillbelevel.
4 Removetheenclosurefromthewallanddrill3/16starterholesfor
thescrewsatthefour(4)markedlocations.
5 Pusheachofthewallanchorsintothedrilledholes,ensuringthe
wallanchorheadsareflushwiththewall.
6 Screwtwo(2)ofthePhillipsheadscrewsintothebottomwall
anchors,leavingtheheadsexposed.
Donotscrewtheseinalltheway.
7 PullthecordfortheGroundedPluginTransformerthroughoneof
theaccessholesorknockoutinthebackoftheenclosure.
8 Pullthewiresforallofthewiredsensorsthroughtheenclosures
accessholesand/orknockoutasneeded.
9 Withtheenclosureinplace,insertthetwo(2)screwheadsintothe
topwallanchors.
Ensurethescrewheadsareattheupperendofthekeyholeslots.
Thentightenbothscrews.
10 Lifttheenclosureandinsertthescrewheadsintothelowerkeyhole
slots.
11 Slidetheenclosuredownwardssothescrewheadsareattheupper
endofthekeyholeslots.
12 Ensurethattheenclosureislevel.
13 Tightenthescrews.
14 Continuewith"MountingthePowerSupplyBoardintheEnclosure"
onpage2.

Copyright 2014 Linear LLC.

Hardwire Conversion Kit (2GIG-TAKE-KIT1) | Installation Instructions

Figure 2 Mounting the Enclosure to the Wall

Mounting the Super Switch in the Enclosure


TomounttheSuperSwitchinsidetheenclosure:
1 Attachtheadhesivebackingtothebacksideoftheplasticwall
bracketfortheSuperSwitch.
TheadhesivebackingisincludedintheHardwireConversionKit.
2 Affixtheplasticwallbrackettotheupperrightcornerofthe
enclosure.Seeposition3inFigure4 MountingtheSuperSwitchin
theEnclosure.
NOTE: Ifinstallingmorethanone(1)SuperSwitchmodule,

mounteachplasticwallbracketverticallyasshowninFigure
4.Theenclosurecanhouseamaximumofthree(3)modules.
3
4
5

Usethetwo(2)sheetmetalscrews(includedwiththeSuper
Switch)tosecurethemoduletotheinsidetheenclosure.
SlidethebackplateoftheSuperSwitchdownwardsoverthe
mountingstubsonthefaceoftheplasticwallbracket.
ToremovetheSuperSwitchbackplatefromtheplasticwall
bracket,slidethebackplateinanupwardsdirectiontoreleaseit
fromthebracketsmountingstubs.

Figure 4 Mounting the Super Switch in the Enclosure


A
B
C
D
E
F
G

One(1)RemovableCover
HingePins
Four(4)KeyholeSlots
Four(4)PlasticWallAnchors(included)
Four(4)PhillipsHeadScrews(included)
Two(2)AccessHoles
One(1)OptionalKnockout

Mounting the Power Supply Board in the


Enclosure
Tomountthepowersupplyboardinsidetheenclosure:
1 Attachthethree(3)doublestickfoamstrips(included)totheflat
surfacesonthebackedgesofthepowersupplyboard.
AsshowninpositionsAandBinthefigurebelow,donotaffixthe
foamstripsovertheedgewiththeexposedpins.
2 Affixtheboardtothelowerrightcorneroftheenclosure.
NOTE: Forsafety,ensurethattheboardisnotcoveringthewiring

accessorkeyholeslots.SeeCinthefigurebelow.
3

(Optional)Usefour(4)sheetmetalscrews(notincluded)tosecure
thepowersupplyboardtotheenclosure.

NOTE: Toavoiddamagingtheboard,donotovertightenthe

screws.
Figure 3 Mounting the Power Supply Board

A SuperSwitchModule(s)
B PlasticWallBracket(s)(bracketsaffixedverticallytobackofenclosure)
C DoublesidedAdhesiveTape(included)and/orOptionalScrewsforPlasticWall
Bracket
D SuperSwitchBackplate,PrintedCircuitBoard,andWiring
E SuperSwitchFrontCover

Wiring the Components


Wiringmustalwaysbeinstalledbyqualifiedservicepersonnelandin
accordancewithNationalElectricalCode,aswellaswithalllocal
codesandauthoritieshavingjurisdiction.
NOTE: TheHardwireConversionKitisintendedforindooruse

only.
Towirethecomponentsinthekit:
1 ConnecttheGroundand12VwiresfromtheSuperSwitchtothe
+VandNEGterminalsonthePowerSupplyBoard.
NOTE: RefertothewiringdiagraminFigure3 "Hardwire

ConversionKitWiring"onpage4.
2
A Three(3)DoubleStickFoamStrips(AffixtoPowerSupplyBoard)
B PowerSupplyBoard(Donotaffixfoamstripsoverexposedpins)
C PowerSupplyBoard(Affixtobackofenclosure)

2 Copyright 2014 Linear LLC.

Attachthepositive(HI)sideofeachwiretothecorresponding
zoneonthesuperswitchterminalblock.

Hardwire Conversion Kit (2GIG-TAKE-KIT1) | Installation Instructions

NOTE: Terminals310onthesuperswitchcorrespondtozones1

8.Forexample,wirethepositive(HI)sideofzone1onthe
SuperSwitchtoterminal3.
3
4
5
6
7

Repeatthestepsaboveforeachadditionalzone.
GrouptheLO/(GND)wirestogetherandconnectthemtoterminal
1/G(GND)oftheSuperSwitch.
ReplacethefrontcoverontheSuperSwitch.
Ensurethepowersupplyismountedintheenclosureincluded
withthe2GIGTAKEKIT1.
Positionthebackupbatteryintherecommendedlocationinthe
enclosure.

11 Connecttheplugintransformer(included)intoanunswitched

walloutlet.
12 Preparetosecurethetransformertotheoutletasfollows:

Forastandardwalloutlet,screwthetransformertotheoutlet.
Thescrewisincludedwiththeplugintransformer.
OR
Foradecorawalloutlet,affixthedoublesidedadhesivetape
tothetransformer.Thenadherethetransformertotheoutlet.

Figure 6 Connecting Power to the Hardwire Conversion Kit

Figure 5 Recommended Location for Backup Battery (Not Included)

A WallOutlet
B PluginTransformerandScrew(included)
C PluginTransformerandDoubleSidedAdhesiveTape(included)forDecora
Outlets
D BacksideofPluginTransformerwithDoubleSidedAdhesivetapeaffixed
A BackupBattery

ConnecttheSuperSwitchtothebackupbatteryasfollows:
8a ConnecttheRED(BAT+)wirefromtheSuperSwitchtotheRED
terminalonthebackupbattery.
8b ConnecttheBLACK(BAT)wirefromtheSuperSwitchtothe
BLACKterminalonthebackupbattery.
ConnectthePowerSupplywirestothebackupbatteryasfollows:
9a ConnecttheRED(BAT+)andBLACK(BAT)wires(provided)
fromthepowersupplytotheBAT+andBATterminalsonthe
PowerSupplyBoard.
9b ConnecttheSpadeLugstothePowerSupplyGroundand12V
wirestothecorrespondingQuickDisconnectConnectorson
theSuperSwitchwires.TheSuperSwitchshouldalreadybe
connectedtothebackupbattery.
9c Connectthe16.5VACleadsforthetransformertothe16.5V
PowerSupply.

NOTE: Toavoidpotentialdamagetothetransformerand

connecteddevices,measurethetransformersoutputvoltage
beforeconnectingittothePowerSupplyBoard.
IMPORTANT: Toavoidnuisancelowbatteryindicatorsfrom

connectedzones,alwayspowerupthebatterybefore
connectingACpower.Ifyouexperienceanissue,see
TroubleshootingtheLowBatteryAlert.
10 Connectthe16.5VACleadstotheACterminalsonthePower

SupplyBoard.

Recommended Maximum Current Draw


Themaximumcurrentdrawfromexternaldevicesshallnotexceed
therecommendationsinthetablebelow:
WhenthisnumberofSuperSwitch
Modulesareinstalled:

Donotexceedthismaximum:

Three(3)Modules
Two(2)Modules
One(1)Module

350mA
400mA
450mA

Troubleshooting the Low Battery Alert


Ifalowbatteryalertappears:
1 UnplugthetransformertopowerdownthePowerSupply.
2 Removeallconnectionsfromthebattery.
3 Testthebatterysvoltagewithabatterylifetestmeter(not
multimeter).
4 Ifthebatteryisfine,rewiretheSuperSwitch.
5 AfterrewiringtheSuperSwitch,reconnectthebattery
connections,connectpowertoTerminal2ontheSuperSwitch,
andthenpluginthetransformer.
NOTE: Toclearthelowbatteryalert,youmayneedtoopenand

closeallofthezonesortoreboottheControlPanel.Toreboot
thepanel,gototheInstallerToolbox,pressSystem
Configuration,andthepressEndatthequestionscreen.
WhentheSummaryofSystemConfigurationscreenappears,
ensuretheSaveChangesboxisselected.ThenpressExit.
NOTE: Allofthegroundwiresmustbegroupedtogetherand

connectedtothegroundportoftheSuperSwitch.
Copyright 2014 Linear LLC. 3

Hardwire Conversion Kit Wiring


UsethediagrambelowwhenwiringtheHardwireConversionKit.
Figure 7 Hardwire Conversion Kit Wiring Diagram

4 Copyright 2014 Linear LLC.

Hardwire Conversion Kit (2GIG-TAKE-KIT1) | Installation Instructions

Installing an Enclosure Door Lock


Theremovablecoverontheplasticwallmount
enclosureisequippedwithanknockoutthat
acceptstheModelH208LockKitfromLinear
LLC.Thisletsyouinstallanoptionalkeylock.
Toinstalltheoptionallock:
1 Temporarilyremovetheenclosuredoor.
2 Locatetheknockoutforthelock.Thisis
locatedinthecenteratthebottomofthe
enclosuredoor.
3 Carefullyremovetheknockoutfromthe
enclosuredoorusingapunchtool.
4 AssemblethedoorlockasdescribedintheH208OwnersManual
(PN:221963A).

Installing a Tamper Switch on the Enclosure


Youcaninstallanoptionalwiredsurfacemountcontact(notprovided)
fromathirdpartymanufacturertoactasanalarmcontactfor
protectingtheenclosure.Iftheenclosurescoverisopened,thealarm
willbeactivated.
Toinstallatamperswitchontheenclosure,usethefollowingasa
guideline:
1 Followthemanufacturersinstructionstomounttheswitchtothe
insidesurfaceofthewallmountenclosure.
2 Placethemagnetontheremovabledoorusingdoublesidedtape
oradhesive.
3 RoutetheHIsidewirefromthesurfacemountcontacttoany
availablezoneterminalontheSuperSwitch.RoutetheLOsideto
theGND.
4 Replacetheenclosuredoor.Afterconnectingpowertothekit,you
willneedtoprogramthetamperswitchintotheControlPanel.To
learnhowtoprogramsensorsintotheControlPanel,seethe
ControlPanelsInstallationandProgrammingGuide.
Figure 8 Replacing the Enclosure Door

SPECIFICATIONS
Enclosure
MaterialandCertification
Dimensions
TakeoverModule
WirelessSignalRange
CodeOutputs
TransmitterFrequency
UniqueIDCodes
SupervisoryInterval
SensorDimensions(LxWxH)
Weight(includingbracket)
HousingMaterial
Color
OperatingTemperatureLimits
RelativeHumidity
OperatingVoltage
Certification
PowerSupplyBoard
Input
Output
BatteryBackup

VisualIndicators
GroundedPluginTransformer
Primary
Secondary
LEDIndicator
PrimaryTermination
SecondaryTermination
Dimensions(WxDxH)
Weight
Color
SurgeProtection:
3ModeProtection
ClampingVoltage
MaximumSpikeCurrent
EnergyDissipation
MaximumSpikeVoltage
ClampingResponseTime
Certification

ABSPlasticUL94V0
11.5x12.5x4in(29.2x31.8x10.2cm)
350ft,openair,withWirelessControlPanel
Foreachoftheeight(8)serialzones:Alarm;
Restore;Fault;LowBattery
345.00MHz(crystalcontrolled)
Overone(1)milliondifferentcode
combinations
70minutes
3.54x2.56x1.13in.(9.0x6.5x2.9cm)
2.85oz.(80.8g)
ABSPlastic
White
32to120F(0to49C)
595%NonCondensing
916VDC,50mA
ETL,FCCPart15,andIndustryCanada
16.5VAC,20VA
12/24VDC
Builtinchargerforsealedleadorgeltype
batteries,automaticswitchovertostandby
whenACfails
ACinputandDCoutputLEDindicators
120VAC60Hz
16.5VAC50VA
SupervisesPower
2MaleBladesandGroundingPin
3#632ScrewTerminalswithwashersfor
securecontact
2.88x2.25x3.88in(7.3x5.7x9.9cm)
1.5lbs
White
Line,Neutral,andGround
340V
4500amps
60joules
6000Volts
25Nanoseconds
UL&ULCListed

A RemovableEnclosureDoor(mustbeinstraightuppositiontoengagehinge
pins)
B HingePins
Copyright 2014 Linear LLC. 5

Hardwire Conversion Kit (2GIG-TAKE-KIT1) | Installation Instructions

Limited Warranty
ThisLinearLLCproductiswarrantedagainstdefectsinmaterialand
workmanshipforone(1)year.Thiswarrantyextendsonlyto
wholesalecustomerswhobuydirectfromLinearLLCorthrough
Linearsnormaldistributionchannels.LinearLLCdoesnotwarrantthis
producttoconsumers.Consumersshouldinquirefromtheirselling
dealerastothenatureofthedealerswarranty,ifany.
TherearenoobligationsorliabilitiesonthepartofLinearLLCfor
consequentialdamagesarisingoutoforinconnectionwithuseor
performanceofthisproductorotherindirectdamageswithrespectto
lossofproperty,revenue,orprofit,orcostofremoval,installation,or
reinstallation.Allimpliedwarrantiesforfunctionality,arevalidonly
untilthewarrantyexpires.ThisLinearLLCWarrantyisinlieuofall
otherwarrantiesexpressedorimplied.

2GIGbyLinear
1950CaminoVidaRoble,Suite150
Carlsbad,CA92008USA
FortechnicalsupportintheUSAandCanada:
8552GIGTECH(8552444832)
Email:2gigtechsupport@linearcorp.com
Visitwebsitefortechnicalsupporthoursofoperation
FortechnicalsupportoutsideoftheUSAandCanada:
Contactyourregionaldistributor
Visitdealer.2gig.comforalistofdistributorsinyourregion
PN:77000069001Rev.B

6 Copyright 2014 Linear LLC.

You might also like