You are on page 1of 72

Bracing Systems

Rod Bracing

Wind Bracing Systems

HOW
BRACING
WORKS
3

Wind Bracing Systems


Load Dispersal

The WIND load on Endwall panels...


4

Wind Bracing Systems


Load Dispersal

is dispersed through Endwall framing...


5

Wind Bracing Systems


Load Dispersal

into the Continuous Purlin system.


6

Wind Bracing Systems


Load Dispersal

The Purlins transfer the load...


7

Wind Bracing Systems


Load Dispersal

into the roof Brace Rods.


8

Wind Bracing Systems


Load Dispersal

The load travels through the Roof bracing...


9

Wind Bracing Systems


Load Dispersal

through the Eave Purlin ...


10

Wind Bracing Systems


Load Dispersal

to the wall Diagonal Bracing ...


11

Wind Bracing Systems


Load Dispersal

...(or auxiliary bracing)...


12

Wind Bracing Systems


Load Dispersal

into the Buildings foundation.


13

Wind Bracing Systems


Load Dispersal

into the Buildings foundation.


14

Transverse (Perpendicular
to Sidewall)

15

Longitudinal (Perpendicular
to Endwall)

16

Standard EP Location

17

Roof Rods Break at Endpost(s)

18

Wind Bracing

If possible, keep endpost spacing


similar at each endwall for a more
efficient bracing pattern.

19

Typical Rod Bracing Location

20

Wind Bracing Systems

Standard
Bracing
Methods
21

Diagonal Bracing
VP standard bracing utilizes Diagonal
Bracing in the Roof and Walls.

The bracing design is determined by:


Building Loads & Code
Building Size
Building Location
22

Diagonal Rod Bracing


Notes about Diagonal Rod Bracing:
Stiffest bracing system available
Most economical bracing system
Eave

Floor
23

Diagonal Rods

24

Diagonal Rods

25

Diagonal Bracing Options


(Rods)
Eave

Floor

26

Alternate Diagonal Bracing

27

Rod Brace Assembly

28

Coupling Nuts

29

Angle Bracing
Bracing may be single rods or
angles depending upon
loading/design

30

Angle Bracing

31

Angle Bracing

32

Angle Bracing

33

Wind Bracing Systems

Alternative
Bracing
Methods
34

Alternative Bracing Methods


Torsional Bracing

Rods are omitted from one sidewall.


35

Torsional Bracing

36

No Torsional Allowed if

37

Alternative Bracing Methods


Notes About Torsional Bracing
Inexpensive

Maximum building width of 50


Maximum eave height of 18
100 mph maximum wind speed
Minimum 3 bays

Call your Service Center if close to these


parameters

38

Rod Brace to Floor

39

Rod Mark Numbers

40

Alternative Bracing Methods


Portal Bracing
Portal Brace Includes:
Portal Beam
Knee Braces
Additional column
support

41

Portal Bracing

42

Portal Bracing

43

Bracing--Wind Posts
Bracing
Bracing
New Bracing Option

Fixed Base Wind Post (with


automated Wind Post Base
Plate Design)
Use at sidewalls or endwalls
35--0 max. eave height
35
Max. 24 column depth
Connection at main frame is
similar to that of portal frame

44

44

Post and Beam Stability


Automated diaphragm check
If fails Rods may automatically be
designed
Initially at interior bay
Then at endbay

45

Post and Beam Stability

46

Alternative Bracing Methods


Notes About Portal Bracing
More expensive than rod
Flexible, not as stiff as diagonal
bracing

Maximum eave height of 20


Special clearances possible
47

Portal Bracing

48

Portal Bracing

49

Portal Bracing???

50

Alternative Bracing Methods


Portal Frames
Portal Frame Includes:

Portal Frame Beam


Portal Frame Columns
Load Transfer Clips
Bolts and Nuts

51

Portal Frame

52

Portal Frame (1/2 offset)

53

Portal Frame

54

Portal Frame

55

Alternative Bracing Methods


Notes About Portal Frames
More expensive than rods
Relatively stiff (can hold drift on frame)
Special clearances possible
(Hold column & rafter depths)

56

Portal Frame

57

Portal Frame

(typical Anchor Rod Detail)

58

Alternative Bracing Methods


Eave

Floor

Combination of Rods and Portal Frame


May be more for building heights
above 20 tall.

59

Partial Height Portal Frame

60

Bracing Comparisons
(Building Size = 200 x 300 x 19, IBC, 85 MPH
Wind - Book Price Shown)

$8,000
$7,000
$6,000
$5,000
$4,000

Rods
Portal Brace
Portal Frame

$3,000
$2,000
$1,000
$0
Bracing Type

61

Strut Bracing at Wall

62

Tube Strut

63

Rod Bracing at Truss Frame

64

Rod Bracing at Truss Frame

65

Rod Bracing at Facade

66

No Bracing?!?!?!
As erection proceeds all Brace Rods,
Flange Braces, Struts, Purlin/Girt Laps
should be installed before proceeding.

All buildings will require some


temporary bracing until all erection is
complete ! Do NOT take any chances !

67

68

69

What Wind Can Do!

70

Bracing Tips
Bracing most effective at 45 degree
angle
Diagonal bracing always most
economical
Consider Interior Column Bracing
at wide buildings
Consider shear walls with masonry,
etc.
71

72

You might also like