1574mm
2534mm
11
6
11
6
Cd orifice
Cd nozzle
Reynold's
Number, Re
0
0
0
202
216
220
222
190
0.001
46
0.662
5
0.736
2554.
73
198
0.0018
6
240
0.0018
6
200
0.0020
4
0.723
0.786
3254.6
56
0.6888
0.766
3254.6
56
0.75
0.82
4199.5
57
Q Ai C D' 2 ghi
80mm 5.0265 10 3 m
D2
4
4
'
C D 0.97; g 9.81m 2 s 1 ; h m
Ai
Q 5.0265 10 3 * 0.97 *
Cd
A 2 gh 1.9635 10 3
0.00237
0.7500
2 * 9.81* 264 132 1000
Q C dO A 2 gh 0.7500 *1.9635 10 3 *
Cd
Q
0.00204
0.8200
A 2 gh 1.9635 10 3 2 * 9.81* 184 102 1000
0.66
0.72
0.69
0.75
0.66
0.72
0.69
0.75
As we can see, for 80mm nozzle, as Cd goes higher due to higher flow rate, the Re also increasing and
this same go to the 50mm nozzle. From the Re number, we can know that this is a type of turbulence
flow since Re is greater than 2300.
Calculation of Re based on 80mm nozzle is (100% opening)
Re
4 air Q
4 1.23 0.00237
4147.06
Dorifice air 50 10 3 1.79 10 5
Re
4 air Q
4 1.23 0.00204
3569.62
Dorifice air 50 10 3 1.79 10 5
(mm)
3
54
294
774
1574
2534
0
0
0
0
0
51.391
2
68.521
6
85.652
102.78
24
119.91
28
942.17
2
736.60
72
85.652
650.95
52
513.91
2
85.852
119.91
28
119.91
28
1010.6
93
805.12
88
102.78
24
119.91
28
137.43
2
1062.0
85
822.25
92
Table of Pressure different (Pa) for 80mm nozzle for the respective tapping position
Different pressure (Pa) for 50mm nozzle
No Points
0
25%
50%
75%
100%
.
(mm)
359.73 496.78 531.04 548.17
0
3
54
84
16
24
28
222.69 308.34 325.47 242.60
0
4
294
52
72
76
8
205.56 291.21 308.34 325.47
0
5
774
84
68
72
76
668.08 925.04 993.56 1027.8
0
8
1574
56
16
35
24
565.30 770.86 822.25 839.38
0
9
2534
32
8
92
96
Calculation for No. 8 (Point 1574mm, 100% damper opening)
Pres
1062.08
3,500.00
sur
3,000.00
e,
822.26
2,500.00
in
100% damper
2,000.00
Pa
75% damper
50% damper
1,500.00
25% damper
1,000.00
500.00
137.43
102.78 119.91
0.00
54
294
774
1574
2534
Pressure in Pa
4000
1027.82
3500
3000
839.39
100% damper
opening
2500
2000
548.17
1500
1000
500
0
54
294
774
1574
2534
As we can see from the graph, as air flow past through the orifice plate, the pressure is slightly higher