Professional Documents
Culture Documents
ZSE30A/ISE30A
2-colour Display
High Precision Digital Pressure Switch
Series
ZSE30A/ISE30A
Features
Adjustable vacuum, positive and compound pressure switch with display.
Large , easy to read, 2 colour (green/red), 4 digit display.
Easy operation: 3-step setting and copy display.
Analogue output: 4-20mA or 1-5V.
Switch output: 2 pnp/npn or 1 pnp/npn.
Replaceable one touch fittings.
Can be panel mounted.
Choice of mounting brackets also available.
Additional functions: Secret code setting function,
power-saving function, resolution-switch function.
Specifications
Note 2)
Voltage
output
Analogue
output
Note 3)
Current
output
Output voltage
Linearity
Output impedance
Output current
Linearity
Load impedance
Display
Display accuracy
Indicator light
Enclosure
Operating temperature range
Operating humidity range
Environment
Withstand voltage
resistance Insulation resistance
Vibration resistance
Impact resistance
Temperature characteristics
Lead wire
Variable (0 or above)
Note 1)
Maximum load impedance: 300 with power supply voltage of 12 V; 600 with power supply voltage of 24 V
Minimum load impedance: 50
4-digit, 7-segment, 2-colour LCD (Red and Green)
2% F.S. 1 digit (ambient temperature of 25 3C)
Lights up when switch output is ON. OUT1: Green, OUT2: Red
IP40
Operating: 0 to 50C, Stored: 10 to 60C (no freezing or condensation)
Operating/Stored: 35 to 85% RH (no condensation)
1000 VAC for 1 minute between live parts and enclosure
50 M or more between live parts and enclosure (at 500 VDC Mega)
10 to 150 Hz, 1.5 mm amplitude (or 20 m/s2 acceleration), in X, Y, Z directions, for 2 hours each (Non-energized)
100 m/s2 in X, Y, Z directions, 3 times each (non-energised)
2% F.S. (based on 25C)
Standards
3.5, 2 m
Conductor area: 0.15 mm2 (AWG26), Insulator O.D.: 1.0 mm
Note 1) If applied pressure fluctuates near the set value, set the hysteresis above the fluctuation range to prevent chattering.
Note 2) When analogue the voltage output is selected, a simultaneous selection of switch output and current output is not available.
Note 3) When analogue the current output is selected, a simultaneous selection of switch output and voltage output is not available.
FOR MORE DETAILS
SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION
1543
Sensors, Switches
Model
Rated pressure range
Regulating pressure range
Proof pressure
Setting/display resolution
Applicable fluid
Power supply voltage
Current consumption
Switch output
Maximum load current
Maximum applied voltage
Residual voltage
Response time
Short circuit protection
Repeatability
Hystere- Hysteresis mode
sis
Window comparator mode
Series
ZSE30A/ISE30A
How to order
Rated pressure range
ISE30A 0.1 to 1 MPa
For positive
pressure
ISE30A
01 N M
For vacuum/
compound pressure
ZSE30A
01 N M
01
None
Bracket A
0 to 101 kPa
100 to 100 kPa
ZS-28-A1
Piping
Bracket B
ZS-28-A2
Straight type
C6L
One-touch fitting 6 mm
Elbow type
ZS-27-C
Sensors, Switches
Display unit
M
Note 1)
Option 1
ZS-27-D
Connector cover
Note) For output types N and P, the number of core of lead wires will
be 3, and for other types, it will be 4.
Piping Specifications
Model
Port size
C4H
C6H
C4L
C6L
4 mm
5/32 inch
6 mm
1544
01
R1/8
M5 x 0.8
4 mm
5/32 inch
Sensor pressure receiving area: Silicon
6 mm
C3602 (electroless nickel plated) PBT, POM, Stainless steel 304, C3604 (electroless nickel plated)
O-ring: NBR
O-ring: HNBR
81 g
70 g
75 g
73 g
71 g
85 g
74 g
79 g
77 g
75 g
43 g
32 g
37 g
35 g
33 g
ZSE30A/ISE30A
ZS-27-01
ZS-38-3L
ZS-38-4L
ZS-38-3G
ZS-38-4G
Part no.
ZS-38-5L
ZS-38-U
ZS-38-C4H
ZS-38-C6H
ZS-38-N7H
ZS-38-C4L
ZS-38-C6L
ZS-38-N7L
ZS-38-H
Option
Front protection cover
Lead wire with connector
Lead wire with connector
Lead wire with connector (with connector cover)
Lead wire with connector (with connector cover)
Option
Lead wire with a connector for copying
Lead wire unit with a connector for copying
One-touch fittings 4 mm straight
One-touch fittings 6 mm straight
One-touch fittings 1/4 inch straight
One-touch fittings 4 mm elbow
One-touch fittings 6 mm elbow
One-touch fittings 1/4 inch elbow
Operating manual CD-ROM
Note
3 cores, for 1 output, 2 m
4 cores, for 2 outputs, 2 m
3 cores, for 1 output, 2 m
4 cores, for 2 outputs, 2 m
Note
3 cores, copy function, 1 m
Copy function (up to 10 slaves)
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
Dimensions
25
2 x M3 x 0.5
thread depth 4
30
9.5
Lead wire with connector
10
30
200.1
M5 x 0.8
01: R1/8
N01: NPT1/8
1.5
W
i
ac dth
fla ross
ts 1
2
Elbow
20.7
One-touch
fitting type
15.6
14
17.55
9.8
Straight
3
4
Straight
A
17.55
17.95
B
9.8
10
A
20.07
22.85
Elbow
B
9.3
11.6
C
15.6
16.1
10.85
9.3
10.85
1545
Sensors, Switches
200.1
Series
ZSE30A/ISE30A
With bracket
30
42.5
25
42.5
30
45
20
(41.4)
20
30
34.6
30
25
1.6
19
20
7.5
16.4
Bracket B
Dimensions
7.2
17.8
9.5
R4.5
34.5
34.5
21
Sensors, Switches
47.8
R4
.5
8.5
Panel thickness 0.5 to 6
11
17.8
9.5
33.5
33.5
1546
13.6
5.2
7.2
20
Bracket A
Panel mount
2
5.
9.1
5.5
30
45
20
14.7
5.2
9.6
2
5.
ZSE30A/ISE30A
Dimensions
Panel fitting dimensions
1 pc. mounting
310.4
4
xR
2
or
s
les
24 or more
R2
or
le
ss
Sensors, Switches
310.4
310.4
24 or more
310.4
R2
or
le
ss
1547
ZSE40/ISE40
Series
High Precision,
Digital Pressure Switch
ZSE40/ISE40
Features
Integrated air pressure or vacuum sensor, IP65 construction
for damp/dirty areas.
Dedicated model for compound pressure (vacuum to low
positive pressure).
Two independently programmable outputs, hysteresis or window comparator operation.
Can be panel or wall mounted plus choice of mounting brackets available.
Digital or digital + analogue outputs.
Autoshift input for remote recalibration, auto preset, NO/NC switching and
display zero functions.
Fast response times, adjustable down to 2.5mS.
Threaded or one-touch fitting pressure connections.
Can display metric or imperial units.
How to Order
Accessories
ISE40
01
22
ZSE40
01
22
Nil
None
Bracket A
ZS-24-A
Sensors, Switches
Bracket B
Nil
F
ZS-24-B
Piping specifications
3m
Panel mount
ZS-22-A
Reverse pressure
two directions
1/8
M5 female threads
Panel mount
+ Front protective cover
1/8
ZS-24-C
Wall mount
Wall mount
Input/Output specifications
4, 6
One-touch fitting
Option
M5
Note
When equipped with auto shift function, the following ranges can be set.
Set pressure range
100.0 to 100.0 kPa
10.0 to 101.3 kPa
0.1 to 1.000 MPa
1548
Setting range
100.0 to 100.0 kPa
101.3 to 101.3 kPa
1.000 to 1.000 MPa
High Precision,
Digital Pressure Switch Series
ZSE40/ISE40
Specifications
Rated pressure range
Operating pressure range/Set pressure range
Withstand pressure
Set pressure
resolution
Applicable fluid
kPa
MPa
kgf/cm2
bar
psi
mmHg
InHg
0.02
500 kPa
0.1
0.001
0.001
0.001
0.01
0.01
0.1
0.01
1
0.1
Air, Non-corrosive/Non-flammable gas
12 to 24 VDC 10%, Ripple (p-p) 10% or less
55 mA or less
NPN or PNP 2 outputs Max. load current : 80 mA
Max. applied voltage:
30 VDC (With NPN output)
Residual voltage
: 1 V or less (With 80 mA load current)
0.2% F.S. 1digit or less
Variable
Fixed (3 digits) Note4)
2.5 ms or less (With anti-chattering function: 24 ms, 192 ms and 768 ms selections)
Yes
3 1/2 digit LED display (Sampling cycle: 5 times/sec.)
Display accuracy
Note)
When equipped with auto shift function, the following ranges can be set.
Set pressure range
Setting range
100.0 to 100.0 kPa
10.0 to 101.3 kPa
0.1 to 1.000 MPa
Function list
Anti-chattering: Adjusts the response time to prevent momentary fluctuations
in the pressure altering the output state.
Key lock: The buttons can be locked to prevent unintentional adjustment.
Peak hold: The maximum value seen by the unit can be retained on the display.
Bottom hold:The minimum value seen by the unit can be retained on the display.
Zero function: The display value can be adjusted back to zero with pressure removed.
Unit conversion:The display unit can be selected to suit user preference.
1549
Sensors, Switches
Indicator light
High Precision,
Digital Pressure Switch
ZSE40/ISE40
Series
7
2.5
7.8
30
1.5
14
4.5
15.2
2.6
10.7
ZSE40(F)/ISE40-01
12
.4
Dimensions
01: R 1/8
20
30
M5 thread depth 5
20
30
MPa
OUT2
6.4
600 (3000)
3.5
Atmospheric
release port
idt
SET
18.35
ha
cr
12 oss fl
ats
OUT1
G 1/8
12
2-M4
thread depth 4
20
30
Rc 1/8
30
20
MPa
OUT2
OUT1
19
SET
6.4
600 (3000)
3.5
Atmospheric
release port
Lead wire length
6.
18.35
For splash proof use (IP65), insert an air tube into the atmospheric
release port.
1550
42
30
10.7
15.2
Sensors, Switches
2.6
2.5
ZSE40(F)/ISE40-WF1
12
7.8
.4
For splash proof use (IP65), insert an air tube into the atmospheric release port.
High Precision,
Digital Pressure Switch Series
ZSE40/ISE40
Dimensions
ZSE40(F)/ISE40
C4
C6
M5
43
10.7
15.2
30
2.
2.5
12
.4
7.8
12
One-touch fitting 4, 6
32.3
30
20
12.8
5
4.
2-
28.15
OUT2
SET
Atmospheric
release port
Lead wire
length
600 (3000)
25.4
6.4
18.35
19
OUT1
3.5
44.3
30
MPa
22.15
Sensors, Switches
For splash proof use (IP65), insert an air tube into the atmospheric release port.
8.5
ForM5
M5 thread depth 5
1551
Series
ISE70
ISE70
Features
Integrated pressure switch for air.
Robust metal case construction.
IP67 waterproof design.
Removable cable.
Red / Green dual colour display.
NPN and PNP outputs available.
Can be operated in hysteresis or window comparison mode.
Mounting bracket available.
How to Order
ISE70 F02 43
2
Piping
G1/4 (ISO1179)
Output
Connector Pin
Assignments
43
Output -43
Fixed setting:
NPN open collector 1 output (Pin no. 4) +
PNP open collector 1 output (Pin no. 2)
65
Sensors, Switches
1 Brown
DC (+)
Option 1
S
Blue
DC ()
Output -65
1 Brown
2 White
3
Blue
4 Black
DC (+)
NC
DC ()
OUT1 (PNP)
Accessories
When option parts are required separately, use the following part numbers to place an order.
Option
Part No.
Note
1
OUT
UP
Bracket
DO
WN
SET
ZS-31-A
Bracket B
Bracket assembly
Lead wire with M12 connector,
straight (spare)
ZS-31-B
ZS-31-C
1552
ISE70
Specifications
ISE70
0 to 1MPa
0.1 to 1MPa
1.5MPa
Proof pressure
0.01MPa
Fluid
12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption
Output -43: Fixed setting; NPN open collector 1 output (Pin no. 4) + PNP open collector 1 output (Pin no. 2)
Switch output
Residual voltage
Response time
2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms)
With short circuit protection
0.5%F.S.
Hysteresis mode
3 digit, 7-segment indicator, 2-colour display (red and green) can be interlocked with the switch output, Sampling cycle: 5 times/s
Display
Display accuracy
Indication light
Anti-chattering function, Unit display switching function, Zero out function, Key lock function
Functions
IP67
Enclosure
Fluid temperature range
Environ-
mental
resistance
Withstand voltage
Insulation resistance
Temperature characteristics
(Based on 25C: Operating temperature range)
2%F.S. or less
Compliant with CE Marking and UL/CSA (UL508) standards
Standard
Wetted material
Fitting: C3602 (electroless nickel plated), Sensor port: PBT, Sensor pressure receiving area: silicon, O-ring: NBR
F02: G1/4 (ISO1179)
Port size
Note 2)
Lead wire
190 g (excluding the lead wire with M12 4-pin pre-wired connector)
Mass (Weight)
Note 1) The NPN and PNP outputs function for a single set point.
Note 2) G1/4: Applicable to ISO1179-1
Dimensions
The dimensions for ISE70 are common to ISE75 and ISE75H. Please see under ISE75 (following pages) for dimensions.
1553
Sensors, Switches
Hysteresis
Note 1)
Note 1)
Series
ISE75
Series
ISE75/75H
Features
Integrated pressure switch for air or fluids.
All wetted parts stainless steel.
Robust metal case construction.
IP67 waterproof construction.
Maximum operating pressure 10 Mpa or 15 MPa.
Orange
Removable cable.
Red / Green dual colour display.
NPN and PNP outputs available.
Gray
ISE75 (10MPa)
How to Order
Sensors, Switches
10MPa
ISE75
F02 43
15MPa
ISE75H F02 43
Piping
F02
1 Brown
3
Blue
Output
43
Fixed setting:
NPN open collector 1 output (Pin no. 4) +
PNP open collector 1 output (Pin no. 2)
65
DC (+)
Note 1)
Connector Pin
Assignments
Output -43
G1/4 (ISO1179)
Option 1
S
DC ()
Output -65
1 Brown
2 White
3
Blue
4 Black
DC (+)
NC
DC ()
Part No.
Note
OUT1 (PNP)
OUT
UP
Bracket
DO
WN
SET
ZS-31-A
Bracket B
Bracket assembly
1554
ZS-31-B
ZS-31-C
ISE75H (15MPa)
ISE75
Specifications
Rated pressure range
Set pressure range
Proof pressure
ISE75
ISE75H
0 to 10MPa
0 to 15MPa
0.4 to 10MPa
0.5 to 15MPa
30MPa
45MPa
0.1MPa
Fluid that will not corrode stainless steel SUS430 and SUS630
Fluid
12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption
Output -43: Fixed setting; NPN open collector 1 output (Pin no. 4) + PNP open collector 1 output (Pin no. 2)
Switch output
Residual voltage
Response time
2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms)
With short circuit protection
0.5%F.S.
Hysteresis mode
3 digit, 7-segment indicator, 2-colour display (red and green) can be interlocked with the switch output, Sampling cycle: 5 times/s
Display
Display accuracy
Indication light
Functions
Anti-chattering function, Unit display switching function, Zero out function, Key lock function
Enclosure
IP67
Environ-
mental
resistance
Withstand voltage
Insulation resistance
Temperature characteristics
(Based on 25C: Operating temperature range)
Sensors, Switches
Hysteresis
Note 1)
Note 1)
3%F.S. or less
Standard
Wetted material
Pressure receiving area: Stainless steel SUS630, Fittings: Stainless steel SUS430
Port size
Lead wire
Note 2)
Mass (Weight)
210 g (excluding the lead wire with M12 4-pin pre-wired connector)
Note 1) The NPN and PNP outputs function for a single setpoint.
Note 2) G1/4: Applicable to ISO1179-1
1555
Series
ISE75
Dimensions
24
Piping port
F02: G1/4 (ISO1179)
34
39
MPa
OUT1
70
UP
DOWN
20
14.5
SET
15.7
(28.7)
(38.2)
With bracket
24
Sensors, Switches
Piping port
F02: G1/4 (ISO1179)
34
44.5
MPa
OUT1
UP
DOWN
90
14.5
SET
5
6.
18.3
(28.7)
(38.2)
1556
35
46
60
Series
ZSE80/ISE80
ZSE80/ISE80
Series
RoHS
Features
Stainless steel construction. Make ZSE/ISE80 suitable for working
with a wide range of fluids, even aggresive
Four pressure ranges available working in the following regimes:
- Vacuum: from -0.1 to 0MPa
- Compound: from -0.1 to +0.1 MPa
- Positive: from -0.1 to +1 MPa and from -0.1 to +2 MPa.
2 -colour display (LCD)
Low leakage versions available.
Simplied operation.
Rear and bottom piping available as standard options.
Analogue current output option added.
Water hammer protection construction.
80 0.1 to 1 MPa
80H 0.1 to 2 MPa
For positive
pressure
ISE 80 02 N
For vacuum/
compound pressure
Accessories
None
With bracket
ZSE 80 02 N
ZS-24-A
Rear ported
With bracket
0 to 101 kPa
80
80F 100 to 100 kPa
ZS-35-A
Bottom ported
Note)
Piping
R1/4
(M5 female threaded)
NPT1/4
N02 (M5 female threaded)
G1/4
F02 (M5 female threaded)
Rc1/8
C01
URJ1/4
A2
TSJ1/4
B2
02
R1/4
(M5 female threaded)
02L
Rear ported
Panel mount
ZS-35-B
Bottom ported
ZS-35-C
NPT1/4
N02L (M5 female threaded)
C01L
A2L
B2L
ZS-24-D
Rear ported
Bottom ported
Rc1/8
URJ1/4
ZS-35-E
TSJ1/4
Input/Output
N
P
A
B
R
T
S
V
ZS-35-F
Rear ported
Bottom ported
1557
Sensors, Switches
How to Order
Series
ZSE80/ISE80
Specifications
ZSE80F
ZSE80
Model
Rated pressure range
Set pressure range
ISE80H
ISE80
(Vacuum pressure)
(Compound pressure)
(Positive pressure)
(Positive pressure)
2 MPa
4 MPa
500 kPa
Withstand pressure
Applicable fluid
Port size
12 to 24 VDC 10%, Ripple (p-p) 10% or less (with power supply polarity protection)
45 mA or less
Current consumption
Switch
output
80 mA
Residual voltage
2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)
Response time
Yes
Repeatability
Hysteresis mode
Hysteresis
Variable (0 or above)
Output voltage
(Rated pressure range)
Approx. 1 k
Output current
(Rated pressure range)
Current
output
1% F.S. or less
Linearity
Output impedance
Analogue
output
1 to 5 V 2.5% F.S.
2.4 to 20 mA
2.5% F.S.
4 to 20 mA 2.5% F.S.
3.2 to 20 mA
2.5% F.S.
1% F.S. or less
Linearity
Load impedance
Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input
Auto-shift input
Sensors, Switches
Display
Display accuracy
Indicator light
Function
IP65
Enclosure
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Temperature characteristics
Lead wire
3.5, 2 m
Conductor area: 0.15 mm2 (AWG26)
Insulator O.D.: 0.95 mm
Standards
G1/4 is available for rear ported only.
Piping Specifications
02
N02
F02
C01
A2
B2
Port size
R1/4
NPT1/4
G1/4
Rc1/8
URJ1/4
TSJ1/4
117 g
118 g
114 g
120 g
111 g
89 g
90 g
86 g
92 g
83 g
Model
1558
86 g
1 x 105 Pam3/s
1 x 1010 Pam3/s
Series
ZSE80/ISE80
Dimensions
02
N02
F02
C01
A2
B2
8.8
14.7
ZSE/ISE8-
M5 thread depth 5
20
49.6
(N02: 50.1)
8.45
30
2 x M3 thread depth 4
10
W
i
ac dth
fla ross
ts 1
7
30
20
26.2
Piping port
02: R1/4
N02: NPT1/4
3.5
46.2
26.2
45.2
26.2
8.45
Piping port
G1/4
Piping port
Rc1/8
19
-C01: Rc1/8
-F02: G1/4
27.7
21.7
8.45
8.45
Piping port
TSJ1/4
Piping port
URJ1/4
-A2: URJ1/4
10.55
Sensors, Switches
-B2: TSJ1/4
1559
ZSE80/ISE80
Series
Dimensions
02L
N02L
C01L
A2L
B2L
8.8
29.5
10.3
ZSE/ISE8-
h
idt
W oss
r
ac 17
ts
fla
M5 thread depth 5
20
41
25.2
10
2 x M3
thread depth 4
60.5
(N02L: 61.5)
30
20
30
3.5
41
64.8
Piping port
Rc1/8
-C01L: Rc1/8
1560
58.8
25.2
49.5
Sensors, Switches
Piping port
02L: R1/4
N02L: NPT1/4
Piping port
URJ1/4
-A2L: URJ1/4
Piping port
TSJ1/4
-B2L: TSJ1/4
Series
ZSE80/ISE80
30
ZS-24-A
4.5
11.5
1.6
4
.5
15
40
55
43.2
20
20
6.5
20
39.7
View A
30
ZS-24-D
4.5
4.2
11.5
15
40
55
43.2
20
20
35
39.7
7.5
22
35
40.3
50
40
30
49
47
60.5
10
4 x 4.5
20
43
30
20
1.5
16.3
35.5
25.2
ZS-35-A
3.5
1561
Sensors, Switches
1.6
7.2
Series
ZSE80/ISE80
Dimensions
Panel mount (Rear ported)
38.6
56.1
25.2
40
51.2
7.5
Panel-cut dimensions
Sensors, Switches
360.3
4 x R3
or less
1562
67 or more
360.3
36
36 x n pcs. + 4 x (n pcs. 1)
4 x R3 or less
Series
ZSE80/ISE80
Dimensions
Panel mount (Bottom ported)
38.6
50
24.2
40
71.1
51.2
7.5
360.3
Sensors, Switches
Panel-cut dimensions
36
360.3
36 x n pcs. + 4 x (n pcs. 1)
4 x R3 or less
4 x R3 or less
1563
PSE530
Series
Pressure Sensor
Series
PSE530
Features
Remote sensor for air or inert gas
1-5 volt analogue output
4 different models to suit pressure or vacuum
Stainless steel case
Removable cable for easy installation
M5 connection port
Option
Compact design
How to Order
PSE53 0
M5
0
1
2
3
Port size
Connector
M5
plug
R06 6
in stem
M5
C2L
Specifications
Model
Rated pressure range
PSE530-M5
PSE531-M5
PSE532-M5
PSE533-M5
0 to 1 MPa
0 to 101 kPa
0 to 101 kPa
1.5 MPa
Proof pressure
500kPa
Air/Non-corrosive gas
Fluid
Power supply voltage
Current consumption
15 mA or less
2% F.S. or less (Within rated pressure range, Ambient temperature 25 3 C)
Linearity
1% F.S. or less
Repeatability
Note
IP40
Temperature range
2% F.S. or less based on the analog output value at 25C from a range of 0 to 50C
Port size
Material
Body: Stainless steel Grade 303, Internal enclosure: PPE; Pressure sensor: Silicon; O-ring: NBR
Halogen-free heavy-duty cord, 2.7, 0.15 mm2, 3 cores, 3 m
Sensor cable/Option
Dimensions
PSE53-M5
Pressure port
43.3
3.4
3.4
5.5
5.4
12
7.2
3
4
12
12
0.5
3
1
7.2
.5
2
29.4
27.2
Dimensions
M5
Pressure port
5.4
Resistance
Enclosure
2.7
Part no.
Connector
1% F.S. or less
1564
Description
Accuracy
10.4
Sensors, Switches
Output specification
Accessories
When only optional parts are required, order using
the part numbers listed below.
PSE540
PSE540
Series
Features
Miniature sensor for dry air and vacuum
Several different porting options
Different pressure ranges available
1 to 5v analogue output
Can be ordered with connector for SMC display unit
Ultra compact and light weight
How to Order
Increased Accuracy
Nil
A
2% FS
1% FS
Option (Connector)
Nil
M3 C2
PSE54 1
Without
Port size
M3
M3
M5
M5
01
R04
4 plug-in reducer
R06
6 plug-in reducer
IM5
M5 female thread,
through type
IM5H
M5 female thread,
through type
(With mounting hole)
Accessories
Description
Connector for PSE200/300
Specifications
Model
Rated pressure range
Proof pressure
PSE540
0 - 1MPa
1.5MPa
C2
Connector for PSE200 or
PSE300 display controllers
1 pc.
Note
1 pc.
PSE541
0 to 101 kPa
500 kPa
Fluid
12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection)
Current consumption
15 mA or less
Output specification
A= 1% F.S.)
0.7% FS
Repeatability
Resistance
Part no.
ZS-28-C
IP40
Withstand voltage
1000 VAC, 50/60 Hz for 1 minute between live parts and case
Insulation resistance
Temperature characteristics
Piping Specifications
Model
M3
Port size
Material
M3
M5
M5
Case
R04
R06
IM5
IM5H
M5 female thread, M5 female thread,
through type
M5
through type (with mounting hole)
plug-in reducer plug-in reducer
Resin case: PBT
Resin case: PBT
PBT
Fitting: C3604BD
Fitting: A6063S-T5
Pressure sensor: Silicon, O-ring: NBR
Sensor cable
Weight
01
R1/8
42.4 g
42.7 g
49.3 g
41.4 g
41.6 g
43.3 g
44.1 g
2.9 g
3.2 g
9.8 g
1.9 g
2.1 g
3.8 g
4.6 g
1565
Sensors, Switches
Series
PSE540
Dimensions
M3
M5
R04
R06
10
PSE5-
With across
flats 7
A
B
10
PSE54-
M3
M5
A
PSE54-M3
PSE54-M5
10.8
11.5
3.5
18
20
Common dimensions
PSE54-IM5
3000
8.7
9.6
18
13
PSE54-R06
PSE54-R04
M5
8.7
10
With across
flats 12
1566
M5
.4
3
13
3
01: R 1/8
14.4
Sensors, Switches
PSE54-IM5H
PSE54- 01
M5
PSE550
PSE550
Series
Features
How to Order
PSE550
Option 2 (Connector)
Nil
Output specifications
Nil
28
None
Connector for PSE300
pressure controller 1 pc.
C2
Description
Bracket
Part no.
Note
ZS-30-A
With M3 x 5L (2 pcs.)
ZS-28-C
1 pc.
Sensors, Switches
Accessories
Specifications
Model
Rated differential pressure range
Operating pressure range
Proof pressure
Applicable fluid
Power supply voltage
Current consumption
Output specification
Environmental
resistance
PSE550
PSE550-28
0 to 2 kPa
50 to 50 kPa Note)
65 kPa
Air/Non-corrosive gas/Non-inflammable gas
12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection)
15 mA or less
Note) Can detect differential pressure from 0 to 2 kPa within the range of 50 to 50 kPa.
FOR MORE DETAILS
SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION
1567
Series
PSE550
Analog Output
1 to 5 VDC
4 to 20 mADC
Analog output [mA]
20
2 Differential
pressure [kPa]
4
2
Differential
pressure [kPa]
Dimensions
Indicator light
24.3
27
37
10.7
7.3
4.8
4.4
37
25
2 x 3.5 through
15
10.4
2-M3 depth 4
With bracket
37
38.5
68
69.5
25
40.9
4.2
27
11.6
7
20
A View
1568
1.6
Sensors, Switches
3000
11.7
ZS-30-A bracket
PSE560
PSE560
Features
Remote sensor for fluids and wet air
All wetted parts stainless steel
1-5v or 4-20mA analogue output
Choice of connection thread types
Robust metal case
IP65 splashproof construction
Available for positive and vacuum pressures
Can be specified with connector for SMC display units
How to Order
Pressure sensing range
Positive pressure (0 to 1 MPa)
Vacuum (0 to 101 kPa)
Compound pressure (100 to 100 kPa)
Positive pressure (0 to 500 kPa)
Option (Connector)
Nil
PSE56 0
01
C2
Without
Port size
Accessories
Output specifications
Nil
28
Description
Specifications
Model
Rated pressure range
Proof pressure
Part no.
ZS-28-C
Note
1 pc.
PSE560
PSE561
0 to 1 MPa
0 to 101 kPa
0 to 500 kPa
1.5 MPa
500 kPa
500 kPa
750 kPa
PSE56-
Model
Fluid
PSE56--28
Fluid, including gas, that will not corrode Stainlesss steel 316L
12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection)
10 mA or less
Current consumption
Output specification
1% F.S. or less
Linearity
Repeatability
Resistance
C2
Connector for PSE300 or
PSE200 displays
1 pc.
IP65
Withstand voltage
Insulation resistance
Temperature characteristics
1569
Sensors, Switches
0
1
3
4
Series
PSE560
Piping Specifications
01
02
R 1/8
R 1/4
M5
M5
Model
Port size
B2
URJ 1/4
TSJ 1/4
Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316L
Material
PSE56-: Oil proof 3-wire heavy-duty vinyl cable with air tube (0.2 mm2)
Sensor cable
Weight
A2
PSE56--28: Oil proof 2-wire heavy-duty vinyl cable with air tube (0.2 mm2)
200 g
203 g
193 g
193 g
101 g
108 g
111 g
101 g
Dimensions
PSE56- 01
02
24
3025
30
5.1
5.5
11.5
24
37.5
14
20
Air tube
M5
Part-C
The dimensions of Part C are common
to all PSE56 models.
Sensors, Switches
PSE56-A2
Model
24
PSE56-B2
B
1570
24
PSE56-01
PSE56-02
PSE56-A2
PSE56-B2
8.2
12
15.5
9.5
R 1/8
R 1/4
URJ 1/4
TSJ 1/4
Controller Series
Controller
Series
PSE300
PSE300
Features
Display unit for remote sensors
Red / Green dual colour display
Two independent digital outputs
Programmable response time and auto-setting function
Optional analogue output or autoshift input
Suitable for all SMC remote sensors with 1-5v output
Power output for sensor to simplify wiring
Can also display imperial units
Panel mounting kit and brackets available, compact design to reduce panel sizes
Keys can be locked to prevent accidental adjustment
How to Order
Input/Output specifications
NPN2 output + 1-5 V output
NPN2 output + 4-20 mA output
NPN2 output + Auto shift input
PNP2 output + 1-5 V output
PNP2 output + 4-20 mA output
PNP2 output + Auto shift input
PSE30 0
L C
Accessories
Bracket
M3 x 5L
Sensor connector
ZS-28-B
Power supply/
Output connection cable
ZS-28-A
Sensor connector
(e-con connector)
ZS-28-C
Bracket
M3 x 5L
Panel mount adapter
Panel
ZS-27-C
Mounting screw
(M3 x 8L)
(Accessory)
Panel
Front protective cover
ZS-27-D
Mounting screw
(M3 x 8L)
(Accessory)
1571
Sensors, Switches
0
1
2
3
4
5
Series
PSE300
Controller
Specifications
Model
10 to 101 kPa
10 to 100 kPa
Pressure range
For vacuum
Note 1)
0.1 to 1 MPa
50 to 500 kPa
0.2 to 2 kPa
0 to 101 kPa
0 to 100 kPa
0 to 1 MPa
0 to 500 kPa
12 to 24 VDC, Ripple (p-p) 10% or less (With power supply polarity protection)
Current consumption
Sensor input
No. of inputs
Input protection
Hysteresis
Switch output
Maximum load current
Residual voltage
Output protection
Response time
1 ms or less
Anti-chattering function
Response time settings for anti-chattering function: 20 ms, 160 ms, 640 ms, 1280 ms
Repeatability
Analogue output
Voltage output
Output voltage: 1 to 5 V (Within rated pressure range (Differential pressure)), Output impedance: Approx. 1 k
Note 2)
Linearity: 0.2% F.S. (Not including sensor accuracy), Response speed: 150 ms or less
0.6% F.S. or less
1.0% F.S. or less 1.5% F.S. or less
Note 2)
Maximum load impedance: 300 (at 12 VDC), 600 (at 24 VDC), Minimum load impedance: 50
Linearity: 0.2% F.S. (Not including sensor accuracy), Response time: 150 ms or less
1.0% F.S. or less
1.5% F.S. or less 2.0% F.S. or less
0.5% F.S.
2 digits or less
Display
3 + 1/2 digit, 7 segment indicator, 2-color display (Red/Green), Sampling frequency: 5 times/sec
Indicator light
Note 2)
IP40
Withstand voltage
Insulation resistance
50 M or more between live parts and case (at 500 VDC Mega)
Temperature characteristics
Connection
Material
85 g
30 g
Analog Output
1
A
C
1572
4 to 20 mADC
Analog output [mA]
1 to 5VDC
Analog output [V]
Sensors, Switches
Resistance
Weight
0 to 2 kPa
Pressure
B
D Differential pressure
20
4
A
C
Pressure
B
D Differential pressure
Range
For vacuum
0 to 101 kPa
A
0
B
101 kPa
For compound
pressure
100 kPa
100 kPa
For positive
pressure
0 to 1 MPa
1 MPa
0 to 500 kPa
500 kPa
Range
0 to 2 kPa
2 kPa
Controller Series
PSE300
Dimensions
31
20 0.1
30
2M3
depth 4
10
1.5
Sensor connector
3.2
1.5
8.2
5
4
3
2
1
Sensor connector
PIN no.
1
2
3
4
20
2 m 20
Terminal
DC (+)
N.C.
DC ()
IN (1 to 5 V)
With bracket
A
30
22
35
41
A View
ZS-28-B
Bracket
24
34.5
11
24
34.5
ZS-27-D
Panel mount adapter + Front protective cover
8.75
ZS-27-C
Panel mount adapter
1573
Sensors, Switches
26.5
1.6
40
7.2
31.5
10
15
4.2
46
20
Series
PSE300
Controller
Dimensions
Panel cutout dimensions
Horizontal stacking mount of multiple units (n pcs.)
31-0.4
31-0.4
31 -0.4
24 or more
Sensors, Switches
24 or more
1574
31 0.4
PSE200
Multi-channel Controller
Series
PSE200
Features
4 Channel display unit
Monitors up to 4 individual sensors
5 outputs plus autoshift input.
Applicable to several sensor ranges
Simpler to connect and use than four separate display units
Saves space compared to four displays
Can display metric or imperial units
Sensors and power lead removable for easy installation
How to Order
PSE20 0
4C
Input/Output specifications
0
1
4C
Accessories
Without panel mount/protective cover
Panel mount
Connector
ZS-26-B
Waterproof seal
(Accessory)
Sensors, Switches
Nil
Option 2
Panel
ZS-26-C
Mounting screws (M3 x 8L)
(Accessory)
ZS-26-A
Panel
48 conversion adapter
ZS-26-D
ZS-26-01
1575
Series
PSE200
Multi-Channel Controller
Specifications
PSE200
Model
Output specification
PSE201
Current consumption
Note 1)
40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
1 to 5 VDC (Input impedance: Approx. 800 k)
Sensor input
4 inputs
No. of inputs
Input protection
Variable
Hysteresis mode
Hysteresis
3-digit fixed
No. of outputs
Switch output
80 mA
Residual voltage
Output protection
Response time
With anti-chattering function, Response time selection: 20 ms, 160 ms, 640 ms
Anti-chattering function
Repeatability
Setting/Display accuracy
For measured value display: 4-digit, 7-segment indicator, Display color: Yellow
Display
Indication light
Non-voltage input (Reed or Solid state), Input 10 ms or more, Independently controllable auto shift function ON/OFF
With auto identification function
Resistance
Temperature characteristics
Connection
Sensors, Switches
Material
Weight
0.1 to 1 MPa
10 to 101 kPa
10 to 101 kPa
kPa
0.1
0.1
0.1
MPa
0.001
kgf/cm2
0.01
0.001
0.001
0.001
bar
0.01
0.001
0.001
0.001
psi
0.1
0.01
0.01
0.02
mmHg
Set pressure
resolution
0.1
0.1
InHg
Note 1) If the Vcc and 0 V side of the sensor input connector are short circuited, the inside of the controller will be damaged.
Note 2) Auto identification function comes with Series PSE53 pressure sensor only. Other SMC series (PSE510 and PSE520) are not equipped with this
function.
1576
PSE200
Dimensions
PSE200 & PSE201
Connector
(option)
7.5
40.1
2.5
40
MPa
kP a
MADE IN J APAN
36.8
PSE200
ZZ
OUT1
OUT2
CH
PRESSURE
SET
Terminal
DC (+)
N.C.
DC ()
IN (1 to 5 V)
Sensors, Switches
Terminal
Pin no.
8 Yellow : Auto shift input
DC (+)
7 Green : CH4_OUT1
DC ()
6 Red
: CH3_OUT1
CH1_OUT1
5 Grey : CH2_OUT1
CH1_OUT2
4 White : CH1_OUT2
CH2_OUT1
3 Black : CH1_OUT1
CH3_OUT1
2 Blue
CH4_OUT1
1 Brown : DC (+)
: DC ()
2000
1577
Series
PSE200
Multi-Channel Controller
Dimensions
Front protective cover + Panel mount
53
(2)
9.4
47
42.4
46.4
MPa
kPa
OUT1
OUT2
CH
1
PRESSURE
SET
Waterproof seal
Panel
2
48
1.5
MPa
kPa
OUT1
OUT2
PRESSURE
SET
Sensors, Switches
Waterproof seal
48 conversion adapter
Panel
55 or more
+0.1
55 or more
37.5-0.2
1578
CH
ISA2
ISA2
Features
Stable detection of objects occluding an orifice
Used to detect presence or absence of a workpiece
Also used to confirm workpieces are correctly positioned
Unaffected by supply pressure variations
Back pressure sensing detects underpressure and overpressure
Also Available
G F E2 1
ISA2
Piping specifications
F
G 1/8
Electrical entry
Pressure gauge
0.2
MPa
0.4
MPa
pressure
0.2 Round
gauge
MPa
0.4
MPa
Straight
Output specifications
1
5
NPN output
PNP output
Nil
Individual wiring
Square embedded
pressure gauge
* Made to order.
Right angle
IISA2 N PL
3 B
Control unit
N
Note) The supply port position is the one when the switch is
viewed from the front.
1
2
3
4
5
6
station
stations
stations
stations
stations
stations
ISA-8-A
Straight, 5 m
ISA-8-B
Right angle, 5 m
Bracket
ISA-4-A
ISA-9-A
Without bracket
With bracket
With mounting
bracket for DIN rail
Nil
* Made to order.
Ordering Example
Individual wiring
Option
Stations
1
2
3
4
5
6
Sensors, Switches
G
H
Individual wiring
air catch sensor
ISA2-GE41N
PU
L L SE T
IN
0.1
0.2
0.3
0 MPa 0.4
Left
With mounting
screw 2 pcs.
FOR MORE DETAILS
SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION
Stations
1579
Series
ISA2
How to Order
DIN Rail
ISA-5-
8
4.5
7.5
35
5.5
35
1.25
Part no.
ISA-5-1
ISA-5-2
ISA-5-3
ISA-5-4
ISA-5-5
ISA-5-6
ISA-5-7
73.0
135.5
173.0
210.5
248.0
285.5
323.0
Applicable models
Individual wiring type Centralized wiring type
IISA2P-1
IISA2S-1
IISA2S-2
IISA2S-3
IISA2S-4
IISA2S-5
IISA2S-6
IISA2P-2
IISA2P-3
IISA2P-4
IISA2P-5
IISA2P-6
GC3
4 AS
Notation
specifications
G36
Notation
specifications
Maximum
pressure
indication
2
4
MPa-PSI
P Note) double
notation
0.2 MPa
0.4 MPa
Maximum
pressure
indication
2
4
Nil
R 1/8
0.2 MPa
0.4 MPa
AR 20
F 02E
VCA27A 5 D S
Voltage
Option specification
N
R
Connection
thread
01
Note) For double notation of MPa and PSI, add -X30 at the end of part number.
Example) G36-P4-01-X30
Regulator
Nil
None
Non-relieving
Flow direction: Right to left
When specifying more than one option, enter symbols first in numerical, then in
alphabetical orders.
Relief pressure
Ambient and fluid temperature
Construction
Weight (kg)
Round
Pressure
0.2 MPa Square embedded Note 2)
gauge
AR20
14
Air
1.5 MPa
1.0 MPa
0.02 to 0.2 MPa
18
0.29
G36-2-01
GC3-2AS
Note 1) The type with square embedded pressure gauge does not have connection.
Note 2) With an O-ring (1 pc.) and mounting screws (2 pcs.).
Valve specifications
Model
Port size
Fluid
Proof pressure
Maximum operating pressure
Set pressure range
Gauge port size Note 1)
100
200
110
220
24
12
230
VAC
VAC
VAC
VAC
VDC
VDC
VAC
Port size
02F
G 1/4
CE
marked
Throttle
Nil Without throttle and manual lock
With throttle
S
With manual lock
B
K With manual lock and throttle
Standard Specifications
Standard Specifications
Coil specifications
Sensors, Switches
1
2
3
4
5
6
36
4 02F Q
1580
ISA2
Specifications
Supply
pressure
Model
Detection distance
Fluid
Operating pressure range
Recommended detection nozzle
50 kPa
Consumption
flow rate
100 kPa
l /min (ANR)
200 kPa
Power supply voltage
Current consumption
Switch Output
ISA2-G1
ISA2-G5
ISA2-H1
0.01 to 0.25 mm
ISA2-H5
0.03 to 0.50 mm
80 mA
30 VDC (at NPN output)
1.5 V or less (at 80 mA)
Yes
0.01 mm or less (Detection distance range 0.01 to 0.15 mm, 0.01 mm or less (Detection distance range 0.03 to 0.15 mm,
supply pressure 100 to 200 kPa)
supply pressure 100 to 200 kPa)
Hysteresis
0.01 mm or less (Detection distance range 0.01 to 0.15 mm) 0.01 mm or less (Detection distance range 0.03 to 0.15 mm)
Indicator light
Sensors, Switches
Weight
1581
Series
ISA2
Right
Left
63(Max. 65)
34
5 17
Stations 1n
Stations
L1
L2
L3
Detection port
G 1/8
19
M4 x 8
(With HW, SW)
46
L1
38
38
L2
End plate L
End plate R
92
81
0.1
0
0.2
0.3
PU
L L SE T
0.2
0.1
0.4
0.3
MPa
0.1
0.4
0.2
Setting dial
0.3
MPa
0.4
21
12
12
MPa
PU
L L SE T
PU
L L SE T
Bracket
5.5
Plug
6.5
Pressure gauge
L3
SUP port
G 1/8
24
24
36
36
Left
Right
Right angle
34
17
1
2
Stations
46
84
L1
L2
38
L3
62.5 120
L4
73 135.5
L5
9.8
Stations 1n
63 (Max. 65)
32.2
Straight union
41
122
38
76
162.5
173
160
76
114
200
210.5
198
114
152
237.5
248
Detection port
G 1/8
19
38
L2
End plate L
End plate R
0.1
20.5
5.25
PU
L L SET
Plug
0.2
0.3
MPa
0.4
PU
L L SET
0.1
0
0.2
PU
L L SET
0.3
MPa
0.4
0.1
0
0.2
Setting dial
DIN rail
center
0.3
MPa
0.4
Pressure
gauge
11.2
L4
L5
1582
18
12
38
SUP port
G 1/8
24
236
152
190
275
285.5
L1
92
81
Sensors, Switches
ISG
ISG
How to Order
ISG 1 1 0
Multipurpose
pressure switch
1
2
03
Port size
Enclosure
2
3
9
0
1
3/8
03 R
N03 NPT 3/8
None
Hysteresis scale plate
Note) Not available for ISG
19/29 type
Material
Contacts/Bulb gland
B
C
Copper alloy
0
1 Stainless steel 316
Specifications
Body material
in contact with
fluid material
Hysteresis
Proof
Operating
Repeatability
pressure range adjusting range pressure
(MPa)
(MPa)
(MPa)
(MPa)
Dripproof
ISG110-030
ISG210-030
ISG110-031
ISG210-031
ISG111-030
ISG211-030
ISG111-031
ISG211-031
ISG120-030
ISG220-030
0.02 to 0.35
ISG120-031
ISG220-031
0.02 to 0.45
ISG121-030
ISG221-030
ISG121-031
ISG221-031
ISG130-030
ISG230-030
ISG130-031
ISG230-031
ISG131-030
ISG231-030
ISG131-031
ISG231-031
ISG190-030
ISG290-030
ISG191-030
ISG291-030
Hysteresis
scale plate
Electrical
entry
Symbol
1.0
0.006
0.05 to 0.7
0.1 to 1.0
0.02 to 0.35
Yes
1.5
0.014
Yes
0.03 to 0.4
1.5
0.02
0.5
2 kPa
Yes
Yes
0.03 to 0.6
JIS F 8801
10 to
7 to 53 kPa
100 kPa
Grommet
0.03 to 0.4
(Open type)
Yes
0.02 to 0.45
0.03 to 0.6
Sensors, Switches
Model
Open type
(Non-waterproof)
Type A
20a
20b
20c
Yes
Ambient and fluid temp.: 5 to 80C (No freezing), Port size: R 3/8,
Weight: 1.3 kg (Open type), 1.5 kg (Dripproof)
Option
Fluid
Type of operating fluid is limited by the material of the wetted parts.
Fluid
Phosphor bronze
Brass
1583
Series
ISG
Dimensions
Open type
ISG110 to 191-030 (Without hysteresis scale plate)
3-6.3
23 20
26
77
30
10 29
126
23 20
26
77
99
R 3/8
54
3-6.3
30 10 29
2.3
54
2.3
8.5
8.5 18
75
110
173
93
110
173
99
126
R 3/8
Dripproof type
ISG210 to 291-030 (Without hysteresis scale plate)
33
9 29
79
R 3/8
JIS F 8801 A type 20a
Cable gland
1584
26
23
33
99
126
30 8.5
175
93
110
175
3-6.3
20
9 29
79
R 3/8
JIS F 8801 A type 20a
Cable gland
23 20
26
99
126
56
3-6.3
2.3
56
75
2.3
110
Setting pressure
adjusting bolt
30 8.5 18
Sensors, Switches
PFM
PFM
Series
Features
Integrated type
Flow range
Model
Sensor unit
PFM710
PFM725
PFM750
PFM711
Model
Display unit
PFM510
PFM525
PFM550
PFM511
PFM3
( ): Fluid: CO2
One-touch fitting: 4, 6, 8
With
flow adjustment
Without
flow adjustment
Straight
Bottom
Straight
IN
S
S
IN
IN
Bottom
S
Sensors, Switches
Piping variations
IN
IN
1
IN
IN
IN
Mounting
Bottom mounting
Bracket
Panel mount
Through-hole
mounting
FOR MORE DETAILS
SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION
DIN rail
1585
Series
PFM
Integrated
display
C4
PFM 7 10
Type
Integrated display
Output specification
A
B
C
D
E
F
G
H
None
Yes
Description
F01
F02
C4
C6
C8
G1/8
G1/4
4 (5/32") one-touch fitting
6 one-touch fitting
8 (5/16") one-touch fitting
NPN outputs
PNP outputs
NPN output + Analogue (1 to 5 V)
NPN output + Analogue (4 to 20 mA)
PNP output + Analogue (1 to 5 V)
PNP output + Analogue (4 to 20 mA)
NPN output + External input Note 3)
PNP output + External input Note 3)
Port size
Symbol
2
2
1
1
1
1
1
1
Sensors, Switches
C4
PFM 5 10
Remote
sensor unit
Type
5
Output specification
No.
Description
1 Analogue output (1 to 5 V)
2 Analogue output (4 to 20 mA)
None
Yes
Port size
1586
Symbol
Description
F01
F02
C4
C6
C8
G1/8
G1/4
4 (5/32") one-touch fitting
6 one-touch fitting
8 (5/16") one-touch fitting
Straight
Bottom
PFM3 0 0
Type
Input specification
Symbol
0
1
PFM
Option 2
Content
Applicable remote type sensor unit
Voltage input
PFM5(S)--1-
Current input
PFM5(S)--2-
None
With sensor connector
Output specification
2
2
2
2
2
2
None
Power supply / Output connector
Note
ZS-28-A
ZS-28-B
With M3 x 5 l (2 pcs.)
ZS-28-C-1
1 pc.
ZS-27-C
With M3 x 8 l (2 pcs.)
ZS-27-D
With M3 x 8 l (2 pcs.)
Sensor connector
Option 1
-
Part no.
Sensor connector
(e-con connector)
ZS-28-C-1
Description
ZS-33-D
Power supply /
Output connector
ZS-28-A
ZS-33-F
S
ZS-33-D
ZS-33-F
Sensors, Switches
0
1
2
3
4
5
IN
ZS-33-M
Mounting
screw
(accessory)
ZS-33-MS
ZS-33-J
Panel mount
adapter B
Panel
Mounting bracket
Panel mount
adapter A
Panel mount
adapter B
ZS-33-JS
Mounting bracket
1587
Series
PFM
Specifications PFM7
PFM710
Model
Note 1)
Linearity
Repeatability
Pressure characteristics
Temperature characteristics
Operating pressure range
PFM711
0.01 l/min
0.1 l/min
0.1 l/min
0.1 l/min
0.1 l/pulse
0.1 l/pulse
0.1 l/pulse
1 l/pulse
1 MPa
Proof pressure
Max. 999999 l
Note 3)
Switch output
80 mA
Output protection
Accumulated pulse output
Response time
Analogue output
Note 4)
Voltage output
Current output
Note 5)
Hysteresis mode
Variable
Sensors, Switches
External input
Display method
Status LEDs
Response time
Hysteresis
PFM750
Applicable fluid
Indication unit
PFM725
Variable
No-voltage input (Reed or Solid state) Input 30 ms or more
3-digit, 7-segment LED
OUT1: Illuminates when output is turned ON (Green). OUT2: Illuminates when output is turned ON (Red).
24 VDC 10%
Current consumption
55 mA or less
Environmental Enclosure
resistance
Operating fluid temperature
IP40
0 to 50C (with no freezing and condensation)
Note 1) User can select between 0.01 l/min and 0.1 l/min for the PFM710, and between 0.1 l/min and 1 l/min for the PFM711 respectively.
If the indication unit is selected to CFM, the minimum unit setting cannot be changed.
At the time of shipment from the factory, the minimum unit setting is set to 0.1 l/min for the PFM710 and 1 l/min for the PFM711 respectively.
Note 2) Set to ANR at the time of shipment from the factory.
ANR is used for standard conditions: 20C, 1 atm and 65%R.H.
Nl/min is used for normal conditions: 0C and 1 atm.
When equipped with a unit switching function. (The SI unit (l/min or l) is fixed for types with no unit switching function.)
Note 3) Cleared when the power supply is turned off. Hold function can be selected. (Interval of 2 min or 5 min can be selected).
If the 5 min interval is selected, the life of the memory element (electronic part) is limited to 1 million cycles. (If energised for 24 hours, life is calculated as 5 min x 1 million =
5 million min = 9.5 years). Therefore, if using the hold function, calculate the memory life for your operating conditions, and use within this life.
Note 4) Set to 1.5 s (90%), can be changed to 100 ms.
Note 5) Set to hystresis mode at the time of shipment from the factory. Can be changed to window comparator mode using push-buttons.
1588
PFM
Specifications PFM5
PFM510
Model
PFM525
PFM550
PFM511
Applicable fluid
Accuracy
3%F.S. or less
Repeatability
Pressure characteristics
Temperature characteristics
Proof pressure
1 MPa
Analogue output
Response time
Voltage output
Voltage output: 1 to 5 V
Output impedance: 1 k
Current output
Current output: 4 to 20 mA
Max. load impedance: 600 , Min. load impedance: 50
Power ON indicator: Lights when power is turned on (Green).
Flow rate indicator: Flashes when flow is applied (Green).
Status LEDs
Power supply voltage
24 VDC 10%
Current consumption
35 mA or less
Environmental Enclosure
resistance
Operating fluid temperature
IP40
0 to 50C (with no freezing and condensation)
Note: Flow rate unit is based on standard conditions (20C, 1 atm, 65% RH).
Specifications PFM3
1 to 52.5 l/min
2 to 105 l/min
CO2
1 to 26.2 l/min
2 to 52 l/min
0.01 l/min
0.1 l/min
0.1 l/min
0.1 l/min
0.1 l/pulse
0.1 l/pulse
0.1 l/pulse
1 l/pulse
Indication unit
Accumulated flow range
1999999 l
Current consumption
50 mA or less
Sensor input
Number of inputs: 1
Hysteresis
Switch output
Accumulated pulse output
Response time
Repeatability
Analogue output
Display accuracy
Display method
Status LEDs
OUT1: Illuminates when output is turned ON (Green). OUT2: Illuminates when output is turned ON (Red).
External input
No-voltage input (Reed or Solid state), LOW level input 30 msec or more, LOW level 0.4 V or less
Enclosure
IP40
Operating: 0 to 50C
1589
Sensors, Switches
PFM3
Model
Note 1)
Series
PFM
Dimensions PFM7
PFM7-C4/C6/C8
(mm)
One-touch fitting
Applicable tube O.D.
4 (5/32")
64.2
92.2
64.6
92.6
28
8 (5/16")
2 x 2.6 depth 5
(34.2)
IN
OUT2
DC ()
DC (+)
OUT
13
43
10.2
OUT1
1/4
18
IN
2 x one-touch fitting
2 x 3.4
18
48
20
28
3 x 2.6 depth 5
OUT
13
(34.2)
IN
18
DC ()
DC (+)
76
58
48
IN
2 x one-touch fitting
18
OUT2
2 x 3.4
1590
OUT1
10.2
43
Sensors, Switches
PFM7S-C4/C6/C8
68
96
64.6
92.6
PFM
Dimensions
IN
OUT
28
IN
IN
IN
Sensors, Switches
52.4
18
43
48
43
29.9
58
42.5
1.2
18 x n pcs. + 34.4
18
48
36
48
18
26
34
28
3.
1591
Series
PFM
Dimensions PFM5
PFM5-C4/C6/C8
(mm)
28
One-touch fitting
Applicable tube O.D.
4 (5/32")
64.2
92.2
64.6
92.6
68
96
64.6
92.6
8 (5/16")
1/4
2 x 2.6 depth 5
IN
OUT1
OUT2
DC ()
DC (+)
OUT
13
(34.2)
43
10.2
IN
2 x one-touch fitting
18
2 x 3.4
A
48
18
FLOW SENSOR
POWER
FLOW
20
28
3 x 2.6 depth 5
OUT
13
(34.2)
IN
DC ()
DC (+)
2 x one-touch fitting
2 x 3.4
B
76
58
48
FLOW SENSOR
18
OUT2
18
1592
OUT1
51.5 (Max.58.5)
10.2
43
Sensors, Switches
PFM5S-C4/C6/C8
POWER
FLOW
IN
PFM
Dimensions
IN
OUT
42.5
FLOW SENSOR
FLOW
52.4
IN
1.2
18
43
48
IN
IN
48
18 x n pcs. + 34.4
36
18
Sensors, Switches
POWER
43
28
29.9
58
FLOW
FLOW
FLOW SENSOR
POWER
3.
FLOW SENSOR
POWER
FLOW SENSOR
FLOW
POWER
FLOW
FLOW SENSOR
POWER
48
18
26
34
28
1593
Series
PFM
Dimensions PFM3
31
20 0.1
2 x M3 x 0.5
Thread depth 4
30
10
1.5
Sensor connector
1.5
3.2
8.2
A
30
With bracket
26.5
1.6
40
31.5
7.2
Sensors, Switches
22
35
41
Bracket
8.75
24
34.5
Panel thickness
dimension: 0.5 to 6
Panel mount adapter
1594
View A
15
10
4.2
46
20
PFM
Dimensions PFM3
Panel fitting dimensions
24 or more
1 pc.
310.4
310.4
0
310.4
4 x R2 or less
4 x R2 or less
Sensors, Switches
310.4
24 or more
4 x R2 or less
Note) If a bend (R) is used, limit it to R2 or less.
1595
PFMV
Series
PFMV
Series
Features
Voltage Monitor
Sensor
Series
PFMV5
Series
PFMV3
PFMV5 05 1
Measurement flow range
0.0 to 0.5 l/min
05
0.0 to 1.0 l/min
10
0.0 to 3.0 l/min
30
05F 0.5 to 0.5 l/min
10F 1.0 to 1.0 l/min
30F 3.0 to 3.0 l/min
Option/Part No.
Part no.
Stations
Remarks
Sensors, Switches
Output specification
1
Analogue
output (1 to 5 V)
Option/Part No.
PFMV3 0 0 M
M3 x 5 l
Power supply /
Output connector
ZS-28-A
Type
3
Sensor connector
(e-con connector)
ZS-28-C
Bracket
M3 x 5 l
Input specification
Symbol
Content
Voltage input
Applicable remote
type sensor unit
PFMV5(F)-1-
Output specification
0
1
2
3
4
5
2
2
2
2
2
2
ZS-28-A
ZS-28-B
Power supply /
Output connector (2mm)
Panel
Panel
ZS-27-C
Mounting
screw
(M3 x 8 l)
1596
ZS-28-C
Sensor connector
1 pc.
Bracket
With M3 x 5l (2pcs.)
ZS-27-D
Mounting
screw
(M3 x 8 l)
PFMV
Specifications PFMV5
PFMV505
Model
PFMV510
PFMV530
PFMV505F
PFMV510F
PFMV530F
1 to 1
l/min Note)
3 to 3
l/min Note)
Dry air, N2
(ISO 8573-1 1.1.2 to 1.1.6: 2001)
Applicable fluid
0 to 0.5
l/min
0 to 3
l/min
0 to 1
l/min
Repeatability
0.5 to 0.5
l/min Note)
2 F.S. or less
Note)
Pressure characteristics
(Based on 0 kPa)
Temperature characteristics
(Based on 25C)
Proof pressure
500 kPa
Response time
Current consumption
16 mA or less
Enclosure
IP40
Fluid temperature
Environmental
resistance
Port size
Wetted parts material
Lead wire
Weight
Note ) Analogue output indicates 3 V when the flow rate is 0. When the flow direction is from IN to OUT, the output is changed to 5 V, and when its from OUT to IN, the output is
changed to 1 V.
Series PFMV3
Model
Applicable sensor
Displayable range
0.70 to 5.10 V: The voltage under 0.7 V is displayed as LLL and that of 5.1 V or more is displayed as HHH.
0.70 to 5.10 V
Settable range
Minimum unit setting
0.01 V
Current consumption
Hysteresis
Switch output
Response time
Repeatability
Analogue output
Display accuracy
Display method
Status LEDs
External input (Auto-shift input)
Withstand voltage
OUT1: Illuminates when output is turned ON (Green). OUT2: Illuminates when output is turned ON (Red).
No-voltage input (Reed or Solid state), LOW level input 5 msec or more, LOW level 0.4 V or less
Enclosure
Operating temperature range
Note)
IP40
Operating: 0 to 50C; stored: 10 to 60C (with no freezing nor condensation)
1000 VAC for 1 min. between whole charging part and live part
Temperature characteristics
Material
Weight
Note) This is the response when the setting value is set to 90% to a 0 to 100% of step input.
FOR MORE DETAILS
SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION
1597
Sensors, Switches
Specifications PFMV3
Series
PFMV
PFMV5
7.1
15
15.2
18
2 x M5 x 0.8
2
x
14
4
3.
0.8
10
34.4
One-side bracket
Both-side bracket
L-type bracket
(Tapped end)
9.1
9.1
20
20
L-type bracket
(Tapped end)
Sensors, Switches
L-type bracket
(Through hole)
PFMV3
31
2 x M3 x 0.5
Thread depth 4
30
10
1.5
20 0.1
Sensor connector
1.5
3.2
8.2
1598
PFMV
With bracket
A
30
26.5
31.5
15
10
7.2
1.6
40
4.2
46
20
22
35
41
Bracket
View A
42.4
7
24
34.5
11
24
310.4
310.4
0
310.4
4 x R2 or less
4 x R2 or less
310.4
1 pc.
24 or more
24 or more
4 x R2 or less
FOR MORE DETAILS
SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION
1599
Sensors, Switches
34.5
PF2A
Series
PF2A
Features
Flow switch for air.
Thermal detection has no moving parts and very little resistance to airflow.
Flow ranges from 1 to 500 l/min.
Integrated LED display can show metric or imperial units.
Two independent digital outputs.
(Integrated display type)
How to Order
Integrated
display type
F 01
PF2A7 10
1
5
10
20
50
to
to
to
to
to
10 l/min
50 l/min
100 l/min
200 l/min
500 l/min
Thread type
F
27
04 1/2
Applicable model
PF2A710, PF2A750
PF2A711, PF2A721
PF2A751
Output specifications
Symbol
Output specifications
Applicable model
27
PF2A710, PF2A750
PF2A711, PF2A721, PF2A751
67
PF2A710, PF2A750
PF2A711, PF2A721/PF2A751
Specifications
Output Note 3)
specifications
Switch output
Resistance
Sensors, Switches
Model
Measured fluid
Flow rate measurement range
Set flow rate range
Flow rate measuring range
Minimum set unit
Accumulated pulse flow rate exchange value (Pulse width: 50 ms)
Note 1) Real-time flow rate
Display unit
Accumulated flow
Operating fluid temperature
Linearity
Repeatability
Temperature characteristics
Current consumption (No load)
Weight Note 2)
Port size ( NPT, G)
Detection type
Display
Operating pressure range
Proof pressure
Accumulated flow range
PF2A710
PF2A750
PF2A711
Air, Nitrogen
5 to 105 l/min
5 to 105 l/min
10 to 100 l/min
1 l/min
1 l/pulse
l, ft3 x 101
0 to 50C
5% F.S. or less
PF2A721
10 to 210 l/min
10 to 210 l/min
20 to 200 l/min
2 l/min
2 l/pulse
l/min, CFM x 101
PF2A751
25 to 525 l/min
25 to 525 l/min
50 to 500 l/min
5 l/min
5 l/pulse
1% F.S. or less
2% F.S. or less
3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C)
160 mA or less
170 mA or less
150 mA or less
290 g
250 g
1/8, 1/4
3/8
1/2
Heater type
3-digit, 7-segment LED
50 kPa to 0.75 MPa
50 kPa to 0.5 MPa
1.0 MPa
0 to 999999 l
Maximum load current: 80 mA; Internal voltage drop: 1 V or less (With load current of 80 mA)
NPN open collector Maximum applied voltage: 30 V; Two outputs
Maximum load current: 80 mA
PNP open collector Internal voltage drop: 1.5 V or less (With load current of 80 mA); Two outputs
NPN or PNP open collector (same as switch output)
Lights up when output is ON OUT1: Green; OUT2: Red
1sec. or less
Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5)
12 to 24 VDC (Ripple 10% or less)
IP65
Operating: 0 to 50C, Stored: 25 to 85C (No condensation or freezing)
1000 VAC for 1 min. between external terminal and case
50 M (500 VDC) between external terminal and case
1000 Vp-p, Pulse width 1 s, Rise time 1 ns
Note 1) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH.
Note 2) Without lead wire.
Note 3) Switch output and accumulated pulse output can be selected during initial setting.
Note 4) Window comparator mode Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more. (In case of output OUT2,
n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
1600
PF2A
42
(41.5)
2-3.4
43
Flow direction
67
58
17
98
82
60
1.6
54
44
FLOW SWITCH
OUT1
OUT2
DOWN
FOR AIR
2-Port size
UP
SET
24
4-4.5
PF2A711/721/751
(41.5)
73
1
Flow direction
64
23
116
88
54
44
FLOW SWITCH
OUT2
FOR AIR
2-Port size
30
44.5
Pin no.
Pin description
DC (+)
OUT2
DC ()
OUT1
UP
SET
OUT1
34
1.6
DOWN
40
50
1601
Sensors, Switches
40
50
PF2A
Series
PF2A
Features
Flow switch for air
Thermal detection has no moving parts
Very little resistance to airflow
Flow ranges from 1 to 500 l/min
Output for remote display, optional analogue output
IP65 splashproof construction
How to Order
Output specifications
F 01
PF2A5 10
Remote type
Display unit
1
5
10
20
50
to
to
to
to
to
1
2
Port size
Nil
10 l/min
50 l/min
100 l/min
200 l/min
500 l/min
04 1/2
Thread type
G
Applicable model
PF2A510/550
PF2A511/521
PF2A551
Specifications
Model
PF2A550
PF2A510
PF2A511
5 to 50 l/min
10 to 100 l/min
Note 1)
1% F.S. or less
2% F.S. or less (15 to 35C, based on 25C)
3% F.S. or less (0 to 50C, based on 25C)
Output Note 2)
specifications
Temperature
characteristics
Analog output
Analogue voltage output (Non-linear) output impedance 1 k output for display unit PF2A3
Voltage output 1 to 5 V within the flow rate range
Linearity: 5% F.S. or less; allowable load resistance: 100 k or more.
Current output 4 to 20 mA within the flow rate range
Linearity: 5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC
12 to 24 VDC (Ripple 10% or less)
IP65
Operating: 0 to 50C, Stored: 25 to 85C (No condensation or freezing)
Withstand voltage
Insulation resistance
Noise resistance
Weight
Note 3)
1602
110 mA or less
100 mA or less
Enclosure
Operating temperature range
50 to 500 l/min
5% F.S. or less
Note 1)
20 to 200 l/min
50 kPa to 0.75 MPa
PF2A551
Heater type
1 to 10 l/min
Proof pressure
Linearity
PF2A521
Air, Nitrogen
Detection type
Resistance
Sensors, Switches
Measured fluid
1)
2)
3)
4)
240 g
200 g
1/8, 1/4
3/8
1/2
PF2A
(43.5)
PF2A510/550
(mm)
42
62
52
72
Output specifications
2-3.4
43
Flow direction
98
82
60
48.2
23
54
44
34
1.6
2-Port size
4-4.5
24
40
50
PF2A511/521/551
Wiring
(mm)
48
62
58
72
Flow direction
116
23
1.6
34
44
76.2
54
30
2-Port size
Blue (3) DC ()
Output specifications
Main circuit
(43.5)
4-4.5
Pin no.
Pin description
DC (+)
NC/Analog output
DC ()
OUT
40
50
1603
Sensors, Switches
PF2A
Series
PF2A
Series
Features
How to Order
PF2A3 0 0
Remote type
Display unit
A
Mounting
0
1
Specifications
Model
1
5
10
20
50
to
to
to
to
to
10 l/min
50 l/min
100 l/min
200 l/min
500 l/min
PF2A510
PF2A550
PF2A511
PF2A521
PF2A551
Output specifications
Symbol
0
1
Applicable model
Output specifications
NPN open collector 2 outputs PF2A300/310
PNP open collector 2 outputs PF2A301/311
PF2A300/301
PF2A310/311
5 to 105 l/min
10 to 210 l/min
5 to 105 l/min
10 to 210 l/min
0.1 l/pulse
0.5 l/min
0.5 l/pulse
Note 4)
Output
specifications
Response time
Hysteresis
Enclosure
Operating temperature range
Withstand voltage
Insulation resistance
Noise resistance
5 l/pulse
1% F.S. or less
50 mA or less
60 mA or less
45 g
Switch output
5 l/min
Weight
Indicator light
2 l/pulse
25 to 525 l/min
5% F.S. or less
Temperature characteristics
1 l/pulse
l, ft x 10
Repeatability Note 3)
Display
2 l/min
25 to 525 l/min
0 to 999999 l
Linearity Note 3)
Current consumption
1 l/min
Resistance
Sensors, Switches
Note 2)
Display unit
0.1 l/min
Panel mounting
Note 1) The flow rate measurement range can be modified depending on the setting.
Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20 C, 101.3 kPa, and 65% RH.
Note 3) The system accuracy when combined with PF2A5.
Note 4) Switch output and accumulated pulse output can be selected during initial setting.
Note 5) Window comparator mode Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more. (In case of output OUT2, n_1, 2 to be
n_3, 4 and P_1, 2 to be P_3, 4.)
1604
PF2A
8-M3
6.4
19.4
36 +0.5
0
36
3 x 7.2(= 21.6)
+0.5
0
View A
40.3
41.8
4.3
40
40
35.8
UNIT
RESET
Analog output
1 to 5 VDC
20
Analog output [mA]
4 to 20 mADC
Sensors, Switches
SET
Min. measured
flow rate value
Part no.
PF2A510--1
PF2A550--1
PF2A511--1
PF2A521--1
PF2A551--1
Max. measured
flow rate value
Real-time
flow rate [l/min]
Basic condition
Standard condition
Minimum measured
flow rate value [l/min]
Minimum measured
flow rate value [l/min]
10
50
5
10
100
20
50
1.1
10.7
5.4
53.5
200
11
21
107
214
500
54
535
Min. measured
flow rate value
Part no.
PF2A510--2
PF2A550--2
PF2A511--2
PF2A521--2
PF2A551--2
Max. measured
flow rate value
Real-time
flow rate [l/min]
Basic condition
Standard condition
Minimum measured
flow rate value [l/min]
Minimum measured
flow rate value [l/min]
10
50
5
10
100
20
50
1.1
5.4
10.7
53.5
200
11
21
107
214
500
54
535
1605
PF2A
Series
PF2A
Series
Features
Port size
Port
Symbol size
How to Order
Integrated
display type
F 10
PF2A7 03 H
Output
specifications
Accumulated Note 3)
pulse output
Analogue output Note 4)
Response time
Hysteresis
Power supply voltage
Current consumption
Enclosure
Operating temperature range
Withstand voltage
Insulation resistance
Noise resistance
Weight
Port size
Resistance
Sensors, Switches
Note
Note
Note
Note
1606
1)
2)
3)
4)
1
11/2
2
Applicable
model
PF2A703H
PF2A706H
PF2A712H
Output specifications
28
29
68
69
Specifications
Model
Measured fluid
Detection type
Flow rate measuring range Note 1)
Minimum setting unit Note 1)
Real-time flow rate
Display unit
Accumulated flow
Operating pressure range
Proof pressure
Pressure loss
Accumulated flow range
Linearity Note 2)
Repeatability
Pressure characteristics
Temperature characteristics
68
10
14
20
PF2A703H
150 to 3000 l/min
5 l/min
PF2A706H
Dry air
Heater type
300 to 6000 l/min
PF2A712H
10 l/min
l/min, CFM
l, m3, m3 x 103, ft3, ft3 x 103, ft3 x 106
Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20 C, 101.3 kPa, and 65% RH.
The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less.
Switch output and accumulated pulse output selections are made using the button controls.
The analog output operates only for real-time flow rate, and does not operate for accumulated flow.
PF2A
Dimensions
PF2A703H/706H/712H
Pin no.
40
Pin description
DC (+)
Analog output
DC ()
OUT1
(41.5)
MODE DOWN
60
A B C D E
F
G
Model
PF2A703H 55 160 40 92 67 55 1"
PF2A706H 65 180 45 104 79 65 11/2"
PF2A712H 75 220 55 114 89 75 2"
Sensors, Switches
U P SET
2-G
36 M5 x 0.8 8
46
M6 x 1
56
M6 x 1
Analogue output
1 to 5 VDC
4 to 20 mADC
20
4
Min. measured
flow rate value
Part no.
Max. measured
flow rate value
Real-time
flow rate [l/min]
Minimum measured
Maximum measured
flow rate value [l/min] flow rate value [l/min]
Min. measured
flow rate value
Part no.
Max. measured
flow rate value
Real-time
flow rate [l/min]
Maximum measured
Minimum measured
flow rate value [l/min] flow rate value [l/min]
PF2A703H--28
PF2A703H--68
150
3000
PF2A703H--29
PF2A703H--69
150
3000
PF2A706H--28
PF2A706H--68
300
6000
PF2A706H--29
PF2A706H--69
300
6000
12000
PF2A712H--29
PF2A712H--69
600
12000
PF2A712H--28
PF2A712H--68
600
1607
Series
PF2W
PF2W
Features
Flow switch for water
Karmann vortex detection method
No moving parts inside the unit
Very little resistance to water flow
Flow ranges from 0.5 to 100 l/min
Integrated LED display can show metric or imperial units
How to Order
Integrated
display type
Output specifications
PF2W7 20
F 03
Port size
Thread type
F
Symbol
03
04
06
10
Specifications
Linearity
Repeatability
Temperature characteristics Note 1)
Current consumption (No load)
Weight
Port size
Detection type
Display
Real-time flow rate
Display unit
Accumulated flow
Operating pressure range
Proof pressure
Accumulated flow range
Ambient temperature range
Note 2)
Output
specifications
Switch output
Resistance
Sensors, Switches
Model
Measured fluid
Flow rate measurement range
Set flow rate range
Flow rate measuring range
Minimum set unit
27
PF2W704
PF2W720
Port
size
3/8
1/2
3/4
1
27
67
PF2W740
Applicable model
PF2W704, PF2W720
PF2W720, PF2W740
PF2W740, PF2W711
PF2W711
PF2W711
Water
1.7 to 17.0 l/min
3.5 to 45 l/min
7 to 110 l/min
0.35 to 4.5 l/min
1.7 to 17.0 l/min
3.5 to 45 l/min
7 to 110 l/min
0.35 to 4.5 l/min
2 to 16 l/min
5 to 40 l/min
10 to 100 l/min
0.5 to 4 l/min
0.1 l/min
0.05 l/min
0.5 l/min
1 l/min
0.1 l/pulse
0.5 l/pulse
1 l/pulse
0.05 l/pulse
5% F.S. or less
3% F.S. or less
3% F.S. or less
2% F.S. or less
5% F.S. or less (0 to 50C, based on 25C)
70 mA or less
80 mA or less
520 g
700 g
460 g
1150 g
3/8, 1/2
3/8
1/2, 3/4
3/4, 1
Karmann vortex
3-digit, 7-segment LED
l/min, gal (US)/min
l, gal (US)
0 to 1 MPa
1.5 MPa
0 to 999999 l
Operating: 0 to 50C, Stored: 25 to 85C (No condensation or freezing)
Maximum load current: 80 mA; Internal voltage drop: 1 V or less (With load current of 80 mA)
NPN open collector Maximum applied voltage: 30 V; 2 outputs
Maximum load current: 80 mA
PNP open collector Internal voltage drop: 1.5 V or less (With load current of 80 mA); 2 outputs
NPN or PNP open collector (same as switch output)
Lights up when output is ON, OUT1: Green; OUT2: Red
1 sec. or less
Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 3)
12 to 24 VDC (Ripple 10% or less)
IP65
0 to 50C
1000 VAC for 1 min. between external terminal and case
50 M (500 VDC) between external terminal and case
1000 Vp-p, Pulse width 1 s, Rise time 1 ns
Note 1) In the case of PF2W711, 3% of F.S. or less (15C to 35C, based on 25C).
Note 2) Switch output and accumulated pulse output can be selected during initial setting.
Note 3) Window comparator mode Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more. The minimum setting unit is 1 digit. (Refer
to the table above.)
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
1608
PF2W
42
73
PF2W704, PF2W720
2-3.4
67
58
43
Flow direction
17
1.6
60
FLOW SWITCH
OUT1
OUT2
DOWN
FOR WATER
4-4.5
L dimension
100
106
Model
PF2W704
PF2W720
Pin no.
1
2
3
4
Pin description
DC (+)
OUT2
DC ()
OUT1
40
50
PF2W740
34
73
(41.5)
Sensors, Switches
2-Port size
34
54
44
UP
SET
Flow direction
120
60
6
17
1.6
60
50
34
FLOW SWITCH
SET
OUT1
OUT2
FOR WATER
2-Port size
34
UP
4-4.5
34
55
67
DOWN
40
50
1609
Series
PF2W
(41.5)
88
46
Flow direction
148
80
77
79
9 2
OUT1 OUT2
2-Port size
Sensors, Switches
1610
45
UP
SET
46
58
70
FLOW SWITCH
4-5.5
36
DOWN
45
32
PF2W
PF2W
Features
Flow switch for water
Remote display type
Karmann vortex detection method
No moving parts inside the sensor
Very little resistance to passage of water
Units with flow ranges from 0.5 to 100 l/min
Output for remote display, optional analogue output
How to Order
Output specifications
Remote type
Sensor unit
F 03
PF2W5 20
Flow rate range
Port size
04 0.5 to 4 l/min
20 2 to 16 l/min
40 5 to 40 l/min
11 10 to 100 l/min
Symbol
Thread type
G
Specifications
PF2W504
Model
03
04
06
10
Nil
1
2
Port
size
3/8
1/2
3/4
1
PF2W520
Measured fluid
Applicable model
PF2W504, PF2W520
PF2W520, PF2W540
PF2W540, PF2W511
PF2W511
PF2W540
PF2W511
5 to 40 l/min
10 to 100 l/min
Detection type
Karmann vortex
0.5 to 4 l/min
2 to 16 l/min
0 to 1 MPa
Withstand pressure
1.5 MPa
0 to 50C
0 to 50C
Linearity Note 1)
5% F.S. or less
3% F.S. or less
Repeatability Note 1)
2% F.S. or less
1% F.S. or less
Output Note 2)
specifications
Temperature characteristics
2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C based on 25C)
Pulse output, N channel, open drain, output for display unit PF2W3.
(Specifications: Maximum load current of 10mA; Maximum applied voltage of 30 V)
Analog output
20 mA or less
Resistance
Sensors, Switches
Water
Enclosure
IP65
Withstand voltage
Insulation resistance
Noise resistance
Weight Note 3)
410 g
470 g
650 g
1,100 g
3/8
3/8, 1/2
1/2, 3/4
3/4, 1
1611
Series
PF2W
(43.5)
PF2W504/520-(N)-
Output specifications
42
62
52
72
2-3.4
43
Flow direction
60
48.2
23
54
44
34
1.6
2-Port size
40
50
4-4.5
PF2W504-(N)-
(43.5)
Wiring
42
62
52
72
Main circuit
Output specifications
Blue (3) DC ()
Flow direction
120
23
2-Port size
1612
60
48.2
34
55
1.6
60
50
Sensors, Switches
Model
L dimension
PF2W504
100
PF2W520
106
4-4.5
40
50
Pin no.
1
2
3
4
Pin description
DC (+)
NC/Analog output
DC ()
OUT
PF2W
63
77
73
87
Output specifications
(43.5)
PF2W511-(N)-
Flow direction
148
80
45
45
4-5.5
Analog output
1 to 5 VDC
36
Sensors, Switches
2-Port size
58
46
70
32
4 to 20 mADC
20
0 Min. measured
flow rate value
Part no.
PF2W504--1
PF2W520--1
PF2W540--1
PF2W511--1
Max. measured
flow rate value
Real-time
flow rate [l/min]
Maximum measured
Minimum measured
flow rate value [l/min] flow rate value [l/min]
0.5
2
4
16
40
10
100
0 Min. measured
flow rate value
Part no.
PF2W504--2
PF2W520--2
PF2W540--2
PF2W511--2
Max. measured
flow rate value
Real-time
flow rate [l/min]
Maximum measured
Minimum measured
flow rate value [l/min] flow rate value [l/min]
0.5
2
16
40
10
100
1613
PF2W
Series
PF2W
Features
Displays flow information
Works with remote sensor units
Panel mounting construction
Clear LED indication and can display metric or imperial units
Two independent digital outputs
Output modes instantaneous flow, total flow and counting pulse
How to Order
Remote type
Display unit
PF2W3 0 0
Mounting
A
0.5 to 4 l/min
2 to 16 l/min
5 to 40 l/min
3 10 to 100 l/mim
0
Specifications
Output specifications
PF2W504
PF2W520
PF2W540
PF2W511
0
1
Panel adapter B
ZS-22-02
Description
Part no.
PF2W300/301
Model
Panel mounting
PF2W330/331
3.5 to 45 l/min
7 to 110 l/min
3.5 to 45 l/min
7 to 110 l/min
0.05 l/min
0.1 l/min
0.5 l/min
1 l/min
0.05 l/pulse
0.1 l/pulse
0.5 l/pulse
1 l/pulse
Accumulated flow
l, gal (US)
0 to 999999 l
Linearity Note 2)
5% F.S. or less
3% F.S. or less
Repeatability Note 2)
3% F.S. or less
1% F.S. or less
Temperature characteristics
Current consumption (No load)
2% F.S. or less (0 to 50C, based on 25C), 1% F.S. or less (15 to 35C, based on 25C)
Output Note 3)
specifications
Insulation resistance
Vibration resistance
10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration in X, Y, Z directions for 2 hrs. each
Display
Indicator light
Power supply voltage
Response time
Hysteresis
Note
Note
Note
Note
1614
45 g
Switch output
Enclosure
60 mA or less
50 mA or less
Weight
Resistance
Sensors, Switches
Display unit
1)
2)
3)
4)
Hysteresis mode: Variable (can be set from 0) Window comparator mode: 3-digit fixed Note 4)
PF2W
36 +0.5
0
3 x 7.2 (= 21.6)
8-M3
19.4
36 +0.5
0
6.4
View A
41.8
40.3
40
4.3
40
35.8
UNIT
RESET
SET
Sensors, Switches
1615
Series
PF2W
Series
PF2W
Features
Flow switch for heated water up to 90C
Karmann vortex detection method
No moving parts inside the unit and very little resistance to water flow
Flow ranges from 0.5 to 40 l/min
Integrated LED display can show metric or imperial units
One digital output plus analogue output
Digital Output modes instantaneous flow, accumulated flow and counting pulse
IP65 splashproof construction with all stainless body parts
How to Order
Integrated
display type
Flow rate range
04 0.5 to 4 l/min
20 2 to 16 l/min
40 5 to 40 l/min
Output specifications
PF2W7 20 T
Symbol
0 to 90C
Thread type
F
27
Port size
Temperature range
T
F 03
27
67
03
04
06
Model
Measured fluid
Flow rate measurement range
Set flow rate range
Flow rate measuring range
Minimum setting unit
Output Note 2)
specifications
Resistance
Sensors, Switches
Specifications
PF2W704T
PF2W720T
PF2W740T
Note 1) 5% F.S. or less (0 to 50C, based on 25C), 3% F.S. or less (15 to 35C, based on 25C)
Note 2) Switch output and accumulated pulse output can be selected during initial setting.
Note 3) Window comparator mode Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more.
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
Note 4) The flow switch is comformed to CE mark.
1616
PF2W
Pin no.
Pin description
DC (+)
OUT2
DC ()
OUT1
Flow direction
74
120
23
1.6
60
OUT1 OUT2
FOR WATER
2-Port size
34
UP
SET
50
60
34
FLOW SWITCH
4-4.5
DOWN
40
50
Sensors, Switches
34
77
1617
PF2W
Series
Series
PF2W
Features
Flow switch for hot water
Remote display type
Karmann vortex detection method
No moving parts inside the sensor
Very little resistance to passage of water
How to Order
Remote type
Display unit
PF2W5 20 T
Temperature range
F 03
Port size
Thread type
0 to 90C
Output specifications
Output for display unit
Nil
1 Output for display unit + Analog output (1 to 5 V)
2 Output for display unit + Analog output (4 to 20 mA)
Applicable model
PF2W504T/520T
PF2W520T/540T
PF2W540T
Specifications
Measured fluid
Flow rate measuring range
Output Note 2)
specifications
Note 1)
5% F.S. or less
Note 1)
Analogue output
2% F.S. or less
2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C based on 25C)
Pulse output, N channel, open drain, output for display unit PF2W3.
(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)
Voltage output 1 to 5 V within the flow rate range
Linearity: 5% F.S. or less; allowable load resistance: 100 k or more.
Current output 4 to 20 mA within the flow rate range
Linearity: 5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC
12 to 24 VDC (Ripple 10% or less)
20 mA or less
IP65
Withstand voltage
Insulation resistance
Noise resistance
Weight
Port size
660 g
3/8
1618
5 to 40 l/min
1.5 MPa
Temperature characteristics
2 to 16 l/min
0 to 1 MPa
Withstand pressure
Repeatability
PF2W540T
Karmann vortex
0.5 to 4 l/min
Linearity
PF2W520T
Water, Mixture of water (50%) and ethylene glycol (50%)
Detection type
Resistance
Sensors, Switches
PF2W504T
Model
3/8, 1/2
1/2, 3/4
PF2W
52
72
62
82
Output specifications
(43.5)
PF2W504T/520T/540T-(N)
Flow direction
B
23
1.6
34
4-4.5
Wiring
40
Analog output
1 to 5 VDC
Main Circuit
50
4 to 20 mADC
1
0 Min. measured
Part no.
PF2W504T--1
PF2W520T--1
PF2W540T--1
Max. measured
Real-time
flow rate value flow rate [l/min]
Minimum measured Maximum measured
flow rate value [l/min] flow rate value [l/min]
0.5
16
40
20
4
0 Min. measured
Part no.
PF2W504T--2
PF2W520T--2
PF2W540T--2
Max. measured
Real-time
flow rate value flow rate [l/min]
Minimum measured Maximum measured
flow rate value [l/min] flow rate value [l/min]
Pin no.
Pin description
DC (+)
NC/Analog output
16
DC ()
40
OUT
0.5
1619
Sensors, Switches
2-Port size
60
50
34
120
60