You are on page 1of 2

Current converter

X244
STV+
Powersupply
Preloadcircuit
+Thyristorblock
Output !

STV-

IGD+

X43

Preload
Thyristor
TDB
ok
ok
ok
1
2
3
Preloadand
5
4
Thyristor
Test
Reset
Start
US
LS
IGDok
UCEok
UCE
6
8

Powersupply
IGD-circuit

IGBT-Test
7

Output !

Reset
T1 T2 T3

IGDOff

T1+/T29

L+

T2+/T113

T2+/T3-

Imax

Powersupply
IGBT-AC-Converter
and
Currentconverter-test

T3+/T1T3+/T2-

T2

T1-T3

LWL-IGD

Current
Converter
OK

Imax

Output !

T1+/T3-

T1

Copying of this Document and giving it to others and the


use of communication of the contents thereof, are forbidden
without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the
grant of a patent or the registration of a utility model or design.

TDB-Circuit

14
10

P24

T3

11
Reset

external Powersupply
24V / 3A
Input !

12

0V

Weitergabe sowie Vervielfaeltigung dieser Unterlage,


Verwertung und Mitteilung ihres Inhalts nicht gestattet,
soweit nicht ausdruecklich zugestanden. Zuwiderhandlungen verpflichten zu Schadensersatz. Alle Rechte fuer den
Fall der Patenterteilung oder GM-Eintragung vorbehalten.

Execute
Testbox SINAMICS Powerblock/ MM4PX
6AG1064-1AA04-0AA0

Datum

24.06.03

Bearb.

Breitschuh

Gepr.

Renner

Testbox SINAMICS Powerblock/ MM4PX


Short description

Siemens AG
A&D SE S3
Zust.

Mitteilung

Datum

Name

Bestell-Nr.
Blatt

6AG1064-1AA04-0AA0

1
2

Bl.

Copying of this Document and giving it to others and the


use of communication of the contents thereof, are forbidden
without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the
grant of a patent or the registration of a utility model or design.

Preload-LED, on, when OK

Thyristor-LED, on, when thyristor in on-state (initiated by push button "START" 5 )

TDB-LED, on, when currentconsumption TDB OK

RESET-Thyristor-button, Reset of LED and powerenable

Start-button, enables firingpulses of thyristors

Switch,choosing: US = upper switch


LS = lower switch
UCE = upper+lower switch

IGD - LED

off = current to low


green= current OK
red = current to high

+
Reset:

must be reseted, when red

UCE - LED, on, when UCE-test OK, must be reseted for each new test

Switch: OFF: Powersupply L+ / T1 - T3 / L- is shut down, test of preload and thyristor possible
T1 / T2 / T3: IGBT- AC-convertertest
choosing Phase T1-:- T3 together with switch 6 choosing of desired IGBT- transistors

Weitergabe sowie Vervielfaeltigung dieser Unterlage,


Verwertung und Mitteilung ihres Inhalts nicht gestattet,
soweit nicht ausdruecklich zugestanden. Zuwiderhandlungen verpflichten zu Schadensersatz. Alle Rechte fuer den
Fall der Patenterteilung oder GM-Eintragung vorbehalten.

Currentconvertertest : 6 different combinations off currentflow inside the currentconverters


When currents are symmetrical, LED is green, when currents are not
symmetrical, LED is red, and must be reseted 11 for each new test.
10

Switch: upside = with connected motor


downside = phases shortened to each other

11

Reset-button: Reset of currentconverter - LED "red"

12

Execute-button: releases all optical signals for IGBT-and currentconvertertest

13

I max- LED L+ : on, when reaching currentsetpoint

14

I max- LED L- : on, when reaching currentsetpoint

Powersupply IGBT-AC-converter and currentconvertertest is not concipated


for long on - duration.
When connected to powerblock, the execute-button should not be pressed longer then 5 seconds.

Datum

24.06.03

Bearb.

Breitschuh

Gepr.

Renner

Testbox SINAMICS Powerblock/ MM4PX


Short description

Siemens AG
A&D SE S3
Zust.

Mitteilung

Datum

Name

Bestell-Nr.
Blatt

6AG1064-1AA04-0AA0

2
2

Bl.