You are on page 1of 142

2015 Viridian Architectural Glass

Selection Guide

viridianglass.com

New World Glass


This Architectural Glass Guide is Viridians key reference
document for industry professionals.
Viridian is Australias number one glass provider and the
only manufacturer of float glass and hardcoat performance
glass products in Australia. Being a part of CSR Building
Products, and with a long history of glass making in Australia,
Viridian is able to offer comprehensive glass and glazing
solutions across Australia and New Zealand.
For the latest version of this glass guide visit the Industry
section at viridianglass.com or call 1800 810 403.

viridianglass.com

Contents
Introduction
Selecting the right glass
5
Glass types and manufacture
6
Sustainability covenant
9
Core Products
VFloat12
Safety Glass
13
VLam14
VTough17
Energy
Energy codes and glass
21
Glass and energy management
22
Reducing building operation costs
23
Solar control, thermal insulation
25
SuperGreen, SuperGrey, SuperBlue
27
Solar Control with Low E
29
SmartGlass31
EnergyTech
32, 33
SolTech
32, 33
EVantage35
ComfortPlus37
ComfortPlus Translucent
39
EnviroShield Performance ITO
41
EnviroShield Performance XIR
43
LightBridge44
ThermoTech46
PerformaTech47
Noise
VLam Hush
55
ComfortHush
56, 57
Clear Vision
SuperClear TC
61
OptiView 
63
Renew65
Decorative
DcorPattern68
Seraphic Standard
71
Seraphic Design
73
DcorSatin74
DcorSatin Grey
74
DcorSatin Mirror
74, 77
VLam Translucent
75
VLam Translucent Grey
75
VLam Soft White
75
DcorMirror77
DcorMirror Laminate
77
DcorMirror Safe
77
DcorPanel79
DcorFloor80
DcorColour81
Digiglass83
Bushfire Protection
PyroGuard 40
86
Structural
ThermoTech Point Fixed IGUs
90
Structural Glazed Systems
92
Profilit93
Balustrade System
95
Storm
StormGuard99
Security
Observa104
IntruderGuard105
AssaultGuard105
AssualtGuard Ultra
106
JailGuard109
BulletGuard110
Bomb & BlastGuard
113
MineGuard113
Knowledge
How to specify clauses
116
Glass physical properties
117
Glass Processing
118
Heat soak treatment
120
Cleaning of glass
121
Standards and warranties
122
Energy Management
Performance Data
124
Performance comparison charts
125
Noise reduction solutions
136
Technical advice and CSR
141
Contact details
142

viridianglass.com

Selecting the right glass

Introduction

The Architectural Glass Guide has been designed

a high priority decision along with appearance

to provide Architects and Specifiers with a broad

(colour, transparency and reflectivity).

range of information relating to glass types,

This information may lead to a glass product type

sizes, properties, behaviours and configurations

with additional attributes such as safety, security,

in Viridians product range. Due to the variety of

decoration, noise control and self-cleaning that

issues that are unique to each project, Viridian

Low E
coating

can be selected.

strongly recommends that prior to commencing

Single
glaze

your project you contact Viridian or your glazing

Document limitations

professional and discuss the specifications of your

This document is not a comprehensive analysis

project and the sustainability of individual Viridian

of all the parameters which may be relevant to

products and make-ups in specific applications.

any particular glass design. Designers should be

Surface 1

Laminated

to develop a suitable solution.

building design and the environment. It affects


design, appearance, thermal performance and

Breakage and minimising risk

occupant comfort. The selection of the right glass


is a crucial component of the design process.

How glass behaves in the case of accidental or


intentional breakage must be considered and

By identifying key issues at the design stage,

while glazing codes and regulations provide the

glassproducts can be selected to match your

minimum requirements, they do not necessarily

specific application. Viridian engineers are

constitute fitness for purpose. Attention is drawn

available to assist when glass is used in structural

to the section in this guide on the heat soak

applications and systems such as Viridian

treatment of Viridian toughened glass and the

Structural Glazing Systems.

strength recommendations of glass in loading

Glass
Surface 1
Interlayer
Low E
coating
Glass
Surface 4

and glazing codes.

Product selection and applications


Viridian products are categorised by their primary
application so that it is easy to find and compare
products. Each category is identified by a symbol
representing the application. Many glass products
are multi-purpose or can be manufactured to
perform many functions.

Insulated glass unit

Standards now call for toughened laminated


glass in some applications such as high level
balustrades and overhead glazing. This type of
glass offers the optimum in structural strength
and safety in the event of breakage.
Considerations of breakage also need to be

Glass
Surface 1

Low E
coating
Surface 2 or 3

Air
space

Glass
Surface 4

considered when determining the type of glass

Specifying
Some of the key decisions that need to be
considered in the selection of glass in facades,
interiors and glazing systems are listed below.
Solar and thermal performance will often be
Product selection considerations
Application
Exterior
 ppearance
A
Colour
Light transmission
Light reflectivity
Decoration
. Glazing dimensions
.

Engineer

Viridian

Surface 2

aware that further information may be required

Glass plays a unique and important role in

Designer

Single glazed

P erformance
Solar control (SHGC)
Thermal insulation
Determine windloads

used in ballistic or bomb and blast applications.


As long as the type and level of threat can be
established, Viridian is able to provide a glass
combination to meet your requirements.

Interior
 ppearance
A
Colour
Transparency
Decoration
. Glazing dimensions
.

Glass Systems
 lazing dimensions
G
. Fitting type
. S upport structure
.

.
.
.

Glass product
is identified

*The additional glass attributes can be incorporated into virtually any Viridian glass.

 etermine windloads
D
Determine deadloads
Glass performance

Additional Attributes*
S afety
Security:
Physical, ballistic
. S elf cleaning
(exteriors only)
. N oise control
.
.

Determine noise
rating (Rw)

 lass attributes are


G
determined, the
specification refined
and thickness
recommended

The chart left shows information


required from designers and engineers
to find the right glass product.
Once the appearance and functional
requirements have been developed by
the designer, the structural engineer will
provide the loads and wind pressure,
the mechanical engineer the thermal
performance requirements and the
acoustic consultant the acoustic
requirements.

Introduction
The float process
> Step 1 The mixed batch of raw
materials is continuously run into the
melting furnace.

Glass types and manufacture


Float glass
The float glass process was invented by
Pilkington, and the first float line in Australia was
commissioned in 1972. CSR building products
purchased the Pilkington Australia business in
2007 and continues to both invest in the process
and set the world standard for the production of
high quality float glass.

> Step 2 At the furnace exit the glass


forms a ribbon floating on the surface
ofmolten tin.

> Step 3 The surface of the molten


tin is extremely flat, imparting perfect
surface evenness to the glass.

Laminated safety glass

dolomite and limestone together and produces

Comprises two or more layers of glass

a continuous glass ribbon up to 3660mm wide.

permanently bonded together with an interlayer

This flows from the furnace and floats over a

or resin. If broken, the interlayer is designed to

bed of molten tin. It is then carefully cooled to

hold the glass together. Virtually all glass types

anneal the glass a process which modifies the

can be laminated and the thickness and type

internal stresses enabling it to be cut and which

of interlayer can be varied to provide safety,

maximises its potential mechanical resistance.

ballistic, bomb or physical attack resistance.

The float glass process is renowned for flatness

Normal laminated glass can be cut and

and optical clarity. It is available in clear, toned,

further processed.

high performance toned, ultra clear low iron glass

Toughened safety glass

and Low E pyrolitic coated. Viridian installed a


CVD coater to the float line, which enables online
Low E coatings to be applied whilst the glass is in

hearth toughening furnace. The glass is heated


then rapidly cooled, resulting in the glass retaining
high compressive stresses. Fully toughened glass
is four to five times stronger than ordinary glass

This involves embossing a pattern into the glass

and if broken fragments into small blunt-edged

during manufacture by passing the semi molten

pieces. Heat strengthened glass has a lower

glass through a set of rollers prior to annealing.

residual stress and is two times stronger than

One side remains smooth whilst the texture is

ordinary glass. It is not a safety glass and if

applied to the other side. A square wire mesh

broken it forms large pieces. Toughened and

can also be included (refer to page 69 for range

heat strengthened glass cannot be cut and both

and sizes).

are resistant to high differential temperatures

Also known as double glazed units, where two or

viridianglass.com

Float or DcorPattern glass is placed in a roller

DcorPattern glass

Insulating glass units

> Step 5 The ribbon is then cut


intolarge plates for shipment.

Toughened glass fragments


into small blunt-edged pieces
when broken.

Glass is manufactured by melting sand, soda ash,

its molten stage of production.

> Step 4 The glass ribbon (2.5mm to


25mmthick) is cooled slowly until it
hasfullyannealed.

Laminated glass is held


together when broken.

(180250C).
Toughened laminated glass

more panels of glass are bonded to a perimeter

This is the optimum in safety glass. Each piece of

spacer, either a metal or thermoplastic spacer,

glass is toughened to provide superior structural

(TPS). Either air or argon gas fills the space

strength when compared to annealed glass.

between the glass panes. Their primary benefit

These pieces are then bonded together using

is insulation and solar control. Most types of glass

either PVB or resin as the interlayer medium,

can be incorporated into an insulating glass unit.

to ensure if the glass breaks the pieces are held


together by the interlayer.

Introduction
Coated Glass

Mirror

This family of high performance glasses consists of

High quality float glass is backed with silver and

permanently bonded microscopically thin layers

protective coats of baked enamel paint. It can

of metal oxides. There are two types of coating

also include a vinyl backing for safety.

technology used in glass supplied by Viridian.


Online, or pyrolitic hard coated. These coatings
are produced by depositing a metallic oxide
gas chemical vapour deposition (CVD) during
float glass manufacture. This process produces
extremely durable coated products that can
easily be handled, transported and processed.
These products typically combine Low-Emissivity
and solar control, and can also provide a
wide range of properties from low reflection
to self cleaning. Viridian has installed a CVD
coater to its float line in Dandenong, which
allows manufacture of a range of Low-Emissivity
glass to meet the growing demand for energy
efficient glass. Viridians local production
will mean we can meet market demand for
prompt supply and flexibility.

Viridian Benefit Categories

Energy Glass that assists in the solar


and thermal control of a building

. 

Screen printed glass

Offline coating. The Airco or magnetron


sputtering uses high-grade glass that is placed
in a series of vacuum chambers and coated
with atoms of alloys such as silver and titanium.
The properties of the metals provide solar
reflectance and Low-Emissivity.

Noise Glass solutions designed


toattenuate sound transmission

. 

. 

. 

Core products Introduces entry


level glass. Glass types include float,
laminate and toughened glass

. 

Uses ceramic paint that is screen printed and


permanently fused to the toughened glass

Clear Vision Glass designed to


improve the clarity of your view

. 

surface. A broad range of colours and designs

Decorative DcorPattern,
formed, mirrors and screen printed
products for design

. 

are available.
Formed glass
Float glass is heated to its softening point and

Bushfire Glass developed for the


protection of people and property
against elements associated with
a bushfire flame front

. 

slumps into a mould that has a custom design


providing a deep DcorPattern.
.

Security glass
Glass designed to resist physical attack, ballistic
and bomb blasts. These products are specialist
laminates that use multiple layers of glass and
rigid interlayers depending on the resistance
required.

S tructural Applications where


glass is used structurally to provide
unrestricted vision such as our
proprietary Structural Glazing Systems
Storm Glass specifically designed
for high wind areas (cyclonic
conditions)

. 

Security Products that are


designedto resist attack from
physical, ballistic and bomb blast

. 

Self cleaning glass


Used for exteriors. The glass incorporates a
pyrolitic coating that dissolves dirt (photo activ)

Coated glasses can be toughened, laminated

and sheds water (hydrophilic) using natural UV

or incorporated into an insulating glass unit.

light and rain.

Under certain light conditions a small degree

Typical glass composition

1% 4%

13%

15%

of haze may be apparent.


16%

51%

Production capabilities
Australia
Laminate

Stock Sheets
Custom

Toughened and
Heat Strengthened

New Zealand

5100 x 3210

5100 x 3210

PVB 5100 x 3210

CIP 3500 x 2500

6000 x 2800

4200 x 2440

Heat Strengthened (thickness)

12mm max

10mm max

Screen Printing

4500 x 2200

3400 x 1750

Heat soak treatment

5500 x 2500

3900 x 2060

IGU (TPS Spacer)


IGU (Metal Spacer)

4500 x 2700

Annealed

3500 x 2000

3500 x 2400

Laminated

3500 x 2000

3500 x 2500

Toughened

3500 x 2000

3500 x 2500

Typical batch of soda lime window


glass. Other constituent ingredients
for providing a solar control tone in the
glass and UV reduction properties.
51% Sand 13% Dolomite
16% Soda ash 4% Limestone
15% Recycled glass 1% Other
Viridian manufactures float glass
in Australia and has an extensive
distribution network throughout
Australian and New Zealand.

viridianglass.com

Viridian the first manufacturer


to sign a sustainability covenant
with the EPA

Introduction

Viridian continues to develop on technology and

Recycling and reducing waste

Why choose Viridian?

innovations that reduce environmental impact

Viridian has also embraced a Target of Zero

. 

of its manufacturing, as well as an overriding

Waste where initiatives already in place have

focus on developing products that lower energy

virtually eliminated packaging and inter-packing

consumption and provide additional comfort in

materials in delivery of Viridian glass. Products

the worlds buildings and cars.

such as DcorMirror eliminate copper coatings,

During 2007, Pilkington Australia signed a

treat and recycle chemicals and glass, unlike

Sustainability Covenant between the Victorian

traditional silvered mirrors.

Environmental Protection Authority (EPA), the

Viridian float production maintains recovery

State Government, The Australian Industry

of around 20% to 30% of in-process waste

Groupand Pilkington to help the company

glass, ensuring sound stewardship of our

sustainably cut the environmental impact

resources, avoidance of material wastes

of itsAustralasian operations.

requiring disposal, and reduction in the energy

Investing in sustainability

usage of the furnace. Waste glass from

Subsequently Pilkington sold its Australian and


New Zealand operation to CSR Building Products
Ltd trading as Viridian. Viridian has already
been certified to Environmental Standard ISO
14001, exceeding EPA standards, and is the
first manufacturer to enter into a covenant.
Significantly, the covenant focuses not only on
manufacturing but also on the development
and support for products that reduce energy
consumption in buildings.
A lot of environmental gains have been made
in traditional improvements at the manufacturing
site about direct emissions to the environment
and we continue to do that and work with
companies to do that, but the really big gains in
the future will be through coming up with smarter
products, commented EPA Victorias Director
of Sustainable Development, Terry AHearn, on
thecovenant.
The covenant relates to the $130 million upgrade
of our major Australasian manufacturing
site in Melbourne that now allows Viridian to
manufacture enhanced energy efficient coatings
for Australian manufactured glass. The new
coated glass technology assists in reducing heat
loss in winter and heat gains in summer, saving
significant CO2 emissions from reduced energy
consumption in heating and cooling.

Viridian sites is also sought after as high-quality


input material for other products, such as
reflective road paints and glass-wool insulation.

Viridian manufactures glass in


Australia and has an extensive
distribution network spanning Australia
and New Zealand
As Australasias only building glass
manufacturer, Viridian is fully
committed to developing the
Australasian building industry
and investing in the future

. 

Did you know?


Viridian is a member of the Green
Building Council of Australia (GBCA).
The objective of the GBCA is to promote
sustainable development andthe
transition of the property industry
toward sustainability by promoting
green building programs (like Green
Star), technologies, design practices
andoperations.

Core Products
Viridian is the only float glass
manufacturer in Australia.
Thefloat glass process is
renowned for flatness and
optical clarity.

viridianglass.com

Core Products
VFloat12
Safety Glass
13
VLam14
VTough17

Setting the standard in clear


and toned glass with infinite
possibilities and applications

Core Products
VFloat

Description

Thermal strength and safety

Viridian VFloat sets the standard for quality

VFloat toned glass is designed to improve

and vision. It is the name we give our base

conditions by reducing glare and solar

products that are manufactured using the float

radiation into buildings. The glass absorbs

glass process. We invite designers, architects

a proportion of the solar heat, which can lead

and engineers to push the boundaries in the

to glass fracture from thermal stress if adequate

use of this extraordinary building material.

precautions are not taken. It is important to note

Glass is produced with brilliant flat surfaces


providing clarity, low distortion and high
daylight transmission. VFloat is manufactured
Applications
Where visibility and light
transmissionare important

. 

General glazing

Further processed as toughened,


laminated, or toughened
laminateglass

6000 x 3210mm*

How to specify
.

S elect glass name


Viridian VFloat

At an early stage of building design or when


specifications are being finalised, Viridian can

enabling designers andcustomers to fill

determine the risk of thermal fracture and

large transparent openings economically.

recommend if heat strengthening or toughening


of the glass is required.

for further processing into a range of products

Design considerations

available for general glazing, laminating,

The maximum sizes in this glass guide are

toughening, high performance coating,

manufacturing sizes and are in excess of the

mirrors and decorative paint finishes.

safeglazing sizes set out in Standards. VFloat

Viridian VFloat Clear provides high light

may also need to be supplied in toughened,

transmission and visibility. It is suitable for

laminated, or toughened laminate form as

conventional and double glazed windows.

required by Standards.

When safety is required for doors and partitions,

Features and benefits

it is specified in toughened, laminated, or

Select thickness process


3mm to 19mm Annealed

the risk of thermal fracture.

It is available inawide range of sizes

Maximum size
. 

damaged during installation as this increases

either clear or toned (grey, bronze and green).

VFloat provides ease of cutting and it is ideal

Insulating glass, mirror coated


andscreen printed

that the edges of solar control glass are not

Clear for maximum daylight transmission


and toned for solar control

. 

toughened laminate forms complying with the


requirements of Building Codes and Standards.


Select colour
Refer to chart below

High clarity, low distortion with brilliant


flat surfaces

. 

VFloat toned glass provides colour and energy


management by reducing solar heat gain,

Wide range of sizes and thickness for


optimum utilisation

. 

while retaining good daylight transmission and


low reflectivity. It also provides reductions in UV.

*N
 ot available in all tones and in all
states of Australia or New Zealand

VFloat toned is available in grey, bronze and


green. It can be toughened, laminated or used

Product range

as a toughened laminate. Similarly it can be

Thickness (mm)
VFloat

8 10 12 15 19

Clear

Clear N
Grey

.
.

Grey N
Bronze

Bronze N
Green
Green N

.
.

Used for glazing, toughening, insulating glass


units, laminating, coating and high quality
Viridian DcorMirror

. 

.
.

.
.

incorporated into Viridian ThermoTech (insulating


glass units) for enhanced solar and thermal
performance. The tone and light transmission

Performance comparison chart

will vary depending on the thickness selected

VFloat*

and this is a design consideration wherecolour

Clear

uniformity is required.

Insulation

Solar

Daylight

5.8

0.82

88

Grey

5.8

0.58

42

Green N

5.8

0.62

76

Bronze N

5.8

0.65

52

6mm glass thickness.

The bar chart diagram is for indication only, for performance


data please refer to the glass performance data tables
at the end of this document.

viridianglass.com

The starting point for safety, security,


noise and structural integrity
The term Safety glass is applied to glazing used

Product details

to reduce the risk of injury from an accidental

. 

impact and consequential glass breakage. Safety


glass is used extensively in both domestic and
commercial buildings, to the requirements ofthe
Building Codes. Viridianoffers the
following types of safety glass:

Viridian VLam (Grade A safety glass) laminated


glass provides protection from injury caused
by sharp splinters of broken glass. If broken,
laminated glass sticks to the interlayer and
generally stays in the window frame to provide
added safety.

Core Products
Safety Glass

Viridian VTough (Grade A safety glass)


toughened glass is up to five times stronger
than annealed glass. On impact, it breaks
into small blunt-edged pieces, reducing the
risk of injury.

. 

Viridian VLam Laminated safety glass

. 

Viridian VTough Toughened safety glass

. 

Viridian VLam Tough Toughened


laminated safety glass

. 

Viridian DcorPattern wired glass Safety wired

. 

Viridian DcorMirror Safe Safety mirror

. 

Critical locations where safety glass must be


considered are outlined in Australian Standard
AS1288 and New Zealand Standard NZS4223:
Doors and sidelights

Viridian VLam Tough (Grade A safety glass)


the optimum in safety glass. Each piece of
glass is toughened to provide superior structural
strength when compared to annealed glass
and then these pieces are bonded together
using either PVB or resin as the interlayer
medium, to ensure if the glass breaks the
pieces are held together by the interlayer.

. 

. 

Viridian DcorPattern wired glass (Grade B safety


glass) is a glass with a wire mesh embedded
into it. When broken, sharp fragments of glass
remain attached to the wire,offering protection
from injury and resistingpenetration.

. 

Glass capable of being mistaken for an


opening, and glazing within 500mm of
the floor

. 

Shower and bath enclosures including


bathroom windows

. 

Shopfronts and internal partitions

. 

Balustrades and stairwells

. 

Schools and childcare buildings where


glass iswithin 1000mm of the floor

. 

Special activity buildings, such as gyms


and swimming pools

. 

Overhead glazing or sloped glass

. 

Australian Standard AS1288 or New Zealand


Standard NZS4223 and AS/NZS2208
These standards recognise two grades of safety
glass Grade A and Grade B. Laminated,
toughened, and toughened laminate glass are
all rated Grade A manufactured to AS/NZS2208,
offering a high level of protection against injury.
Laminated glass also offers security and noise
control benefits. Grade B safety glass provides
alower level of safety. Safety wired glass is
rated Grade B and is limited in its applications.
Australian Standard AS1288 or New Zealand
Standard NZS4223 and the respective Building
Codes identify minimum areas where safety
glass mustbe used.

Viridian DcorMirror Safe safety mirror is a


high specification mirror with a special safety
backing film to retain broken pieces of mirror
if broken from impact.

. 

Did you know?


Viridian has the capability to
manufacture the largest stock laminate
in the Southern Hemisphere
5500mm x 3210mm

Core Products
VLam

The starting point for safety, security,


noise and structural integrity
Product description
Viridian VLam consists of two or more sheets of
glass bonded together by heat and pressure with
an interlayer of either PVB, EVA or a specialist high
strength ionoplast interlayer.
Resin Pour or Cast In Place (CIP) is another form
of lamination. Edge tape is applied to the edge
of the glasses before a liquid resin is poured
between the two sheets. The resin is cured under
UV lights. Only available in New Zealand.

How to specify
Select glass name
Viridian VLam

. 

Select thickness process


6.38mm to 39.52mm Laminated
7.52mm to 39.52mm
Toughened Laminate

. 

Select colour
Refer to range chart on page 15

. 

VLam, if broken the glass is bonded


to an interlayer.

viridianglass.com

The result is a durable, adaptable high


performance glazing material that can provide
solutions to many architectural applications.
Within the Viridian range there is a wide
varietyof laminated glass options.
Features and benefits
Safety in vertical or sloped overhead
applications, laminated glass can resist
penetration from accidental impact. If the glass
is broken, fragments adhere to the interlayer
and are retained in place. VLam provides
safety from contact with broken or falling glass,
or bodily injury by falling through the glass. In
certain applications, toughened laminated
glass must be used, such as sloped overhead
glass.

. 

Security standard laminated glass provides


resistance to penetration from physical attack.
By increasing the thickness of the interlayer
and its strength, as well as using multiple glass
interlayer constructions, products are offered
forspecialist security applications including
bullet and bomb resistance (refer to page 110
and 113).

. 

Noise control VLam provides good noise


dampening over the same thickness of float
glass. By incorporating VLam into a
Viridian ThermoTech insulating glass unit,
excellent noise attenuation can be achieved.
Viridian VLam Hush uses a specially
developed interlayer for enhanced noise
reduction (refer to page 55).

. 

UV protection the PVB interlayer used in


VLam eliminates 99% of ultraviolet radiation.
When incorporated with solar control glass,
fading can be reduced up to 8.5 times over
normal glass.

. 

Solar control VLam can be manufactured


with toned solar control glass and interlayers
providing glare and solar heat gain reductions.
Further to this, VLam can be customised with
virtually any Viridian solar control glass for the
ideal balance between daylight solar control
and thermal insulation.

. 

Core Products
Colour and decoration soft white, translucent
and translucent grey interlayers, along with
the Viridian DcorPattern glass options are
available for privacy and light diffusion. The
Viridian Seraphic Design range can also be
laminated providing options for screen printed
colours and designs.

. 

Considerations
Glass selection, glazing and manufacturing
must be in accordance with Australian and
New Zealand Standards refer to standards on
page 122 for an explanation on each standard.

. 

Interlayer colours are based on but are not


identical to 6mm Viridian VFloat glass
colours.

. 

Custom laminating
The laminating process provides almost limitless

VLam

The glazing system must allow for water


drainage or be completely watertight.

. 

options in glass configurations. Combinations

Certain sealants may cause edge


de-lamination such as linseed oil putty neutral
cure silicone sealants are recommended.

. 

of solar control glass, special interlayers, Low E


and coated glass, as well as decorative glass
provide tailored solutions. Toughened laminated

Laminated glass edges left exposed are


notrecommended.

. 

glass is also available for large overhead spans


and additional safety in balustrades and Viridian

Overhead glazing

. 

Residential and commercial


buildings where safety glass is
required

. 

Warranty, refer to page 122.

. 

Structural Glazing Systems. Glass options for

Applications

floors and very thick glass for aquariums are

Safety

also available.

A range of laminated and


toughened laminated glass
for safety applications

. 

Interlayer thicknesses
The standard PVB interlayer is 0.38mm thick.

Noise

Also available are 0.76mm and 1.52mm for

VLam Hush

increased resistance to penetration and security

. 

applications.

. 

ComfortHush

Decorative

Resin Pour or Cast in Place (CIP) is another type

DecorColour

. 

of lamination. This is available in New Zealand

VLam Translucent, Translucent Grey,


Soft White

. 

for customised solutions.

DigiGlass

. 

Solar Control
VLam Grey, Bronze, Green,
SuperGreen, SuperBlue

. 

VLam range
Thickness (mm)
Product

Max size (mm)

6.38

6.76

8.38

10.38

12.38

ComfortPlus

. 

EnviroShield Performance

. 

Clear

5100 x 3210

Security

Bronze

3660 x 2440

. 

Green

4600 x 2760

. 

Grey

5100 x 3210

. 

Soft White

3660 x 2440

. 

SuperGreen

5100 x 3210

. 

Translucent

5100 x 3210

Special Applications

3660 x 2440

. 

3660 x 2440

. 

Translucent Grey
Cool Blue
Max size not available in all thicknesses.

.
.

Observa
IntruderGuard
AssaultGuard
AssaultGuard Ultra
JailGuard

StormGuard
BulletGuard
Bomb and BlastGuard

. 

MineGuard

. 

viridianglass.com

Creating physical but not


visual boundaries
Whenever the benefits of ordinary glass need to

Features

be combined with extra strength, safety or heat

. 

resistance, Viridian VTough toughened glass


offers a complete and proven solution, allowing
designers and specifiers greater scope with glass
for building.
Product description
VTough toughened glass is a Grade A safety
glass manufactured to AS/NZS2208 for use in
buildings or AS/NZS2080 safety glass for land
vehicles. It is manufactured by heating and then
rapidly cooling float glass. As a result, opposing
compressive and tensile stresses are set up in the
glass, which gives toughened glass four to five
times more strength than ordinary glass of the
same thickness, combined with much greater
resistance to impact. In the unlikely event of
breakage, VTough fragments into small bluntedged pieces, reducing the risk of injury. VTough
toughened glass cannot be cut or edgework
processed after manufacture.
Considerations
Heat soak treatment is recommended
in certain applications by Viridian to provide
a superior quality glass and may be a Viridian
warranty requirement. In accordance with
the BCA (2010) heat soak treatment testing on
toughened glass will be mandatory in certain
applications (more information please refer
page 120).

. 

Tolerances as listed in AS/NZS2208,


toughened glass is inherently less flat than
ordinary glass.

. 

Windload toughened glass can be used in


larger areas than ordinary glass of the same
thickness. This allows a consistent thickness and
appearance to be achieved in areas of higher
windload or panel dimensions. Deflection
should be checked.

. 

Selection and glazing glass must be


selected and installed in accordance with
Australian Standard AS1288 or New Zealand
Standard NZS4223. Attention is also drawn to
the breakage characteristic of toughened glass
and it is the specifiers responsibility to assess
each application.

Strength toughened glass allows large, clear


spans with minimum fixing. Toughened glass
is used with bolt or patch fittings for frameless
doors and assemblies, or glass shapes,
including holes, that may weaken normal
annealed glass. Toughened glass has good
resistance to soft object impacts. For example,
it is often used for basketball backboards.
Thermal resistance resists temperature
differences of 250C in a range of 70C to
+300C. This means that toughened glass can
be used in appliances, splashbacks and where
thermal stress breakage is an issue.

Core Products
VTough

. 

Range
Virtually all glass types can be supplied in
toughened form, the exceptions being some
deeply DcorPatterned glass, wired and glass
for leadlighting.
Heat strengthened glass this is not a safety
glass, but has approximately double the
strength of ordinary glass. It is resistant to
thermal breakage (temperature differential
of 160C) and if broken, breaks into larger
pieces. This glass is used in building spandrel
areas because it has less distortion than
fully toughened glass or is also used where
additional strength without safety is required.

. 

Viridian Seraphic is toughened glass with a


screen printed ceramic solid colour or design
(refer page 73 and page 81).

. 

VLam Tough can be laminated for


additional safety, solar control or appearance.

. 

Benefits
Wide range of glass types available.

. 

Manufactured and distributed throughout


Australia and New Zealand for ease
of availability.

. 

Heat soak treatment recommended


(more information please refer page 120).

. 

Applications
Residential and commercial
buildings where Grade A safety
glassis a requirement

. 

Shower enclosures

. 

Spandrel and thermal safety

. 

Furniture

. 

Balustrades

. 

Shopfronts and entrances

. 

Minimum size
300 x 150mm

. 

Maximum size
Aust. 5500 x 2800mm
NZ. 3900 x 2080mm

. 

Thickness
4mm to 19mm glass

. 

How to specify
Select glass name
Viridian VTough

. 

Select thickness process


4mm to 19mm Toughened
4mm to 12mm Heat
Strengthened
9.52mm to 39.52mm
Toughened/Laminate

. 

Select colour
From VFloat range

. 

. 

VTough toughened glass, if broken


fragments into small blunt-edged pieces.

Energy
Creating sustainable, energy
efficient buildings. Reducing building
operation lifecycle costs. The positive
influence of daylight on human
productivity. These are the benefits
of Viridian glasstechnology,
providing a spectrum of solutions
for specifiers... and for the planet.

viridianglass.com

Energy
Energy codes and glass
21
Glass and energy management
22
Reducing building operation costs 23
Solar control, thermal insulation
25
SuperGreen27
SuperGrey27
SuperBlue27
Solar Control with Low E
29
SmartGlass31
EnergyTech
32, 33
SolTech
32, 33
EVantage35
ComfortPlus37
ComfortPlus Translucent
39
EnviroShield Performance ITO
41
EnviroShield Performance XIR
43
LightBridge44
ThermoTech46
PerformaTech47

viridianglass.com

Energy codes and glass

Energy

Reducing energy consumption in every aspect of

adjustment (for conductance). The performance

our lives is high on the national agenda. Buildings

data presented in this guide is for glass only.

in which we live and work consume significant


amounts of energy with correlating greenhouse
gas emissions. In response to this, government
has developed mandatory minimum Energy
Efficiency Measures. These regulations cover both
residential and commercial construction types.

The deem to satisfy provisions of the code


are aimed at allowing unlimited mixing of
glazing sizes, glass and frame types. Glazing
requirements in each climate zone are a function
of floor area, conductance and solar radiation
of the glazing system, orientation, shading

Energy use modelling has shown that the

devices and window area. The code recognises

selection and placement of glazing is one of the

high performance glazing through maximising

most critical elements in designing for energy

allowable window sizes.

efficiency. In large commercial and apartment


buildings where the roof is a smaller proportion of
the building envelope, treatment of glazing is the
most important design consideration. Selecting
the right glass allows designers to maximise light,
while insulating against heat loss and selectively
shielding unwanted heat gain. Choosing the right
balance of these factors during the design phase
will provide a comfortable, healthy and energy
efficient environment for the life of the building.

Generally, southern locations will often require


products with high performance thermal insulation
(lower U Values), while in a northern location,
solar radiation (lower SHGC value) will usually be
the critical component. In the more temperate
locations, a combination of U Value and or
SHGC could be the critical component. Viridian
offers a range of products that can meet these
various requirements. A simple chart reference
indicating the relative performance by product

The code is performance based, offering a

for daylight transmission, thermal insulation

number of paths to compliance and sets out the

(conductance) and solar control is shown in the

performance that a building has to achieve. In

glass performance data tables on page 125.

The performance data for Viridian


glass is derived using the International
Glass database and software
developed by Lawrence Berkley
University. The international standard of
measurement used is NFRC 100-2001
conditions. All relevant guidelines of the
National Fenestration Council (NFRC)
have now been changed to the
Technical Protocols and Procedures
Manual for the Energy Rating of
Fenestration Products by the Australian
Fenestration Rating Council (AFRC).
The combination of the SHGC and
UValue determines the performance
of the glass and its energy contribution.
The building structure, glass framing
system and orientation will all
contribute to determining the overall
environmental performance of the
facade and the building. It should
be noted that performance data
presented in this guide is for glass only
and a window rating or assessment
is required.
Not all manufacturers data is
calculated using NFRC 100-2001
conditions, in particular some countries
have different conditions that will
impact on the glass performance.

terms of glazing, the key focus is on minimising


the rate of summertime heat gain and winter
heat loss (the emphasis will shift depending on

Climate zones

the climate zone). The requirements will also vary


depending on the nature and type of heating
and cooling systems employed, if any.
Glazing performance is measured in terms of
U Value (for conduction) and solar heat gain
coefficient (SHGC), and is based on Australian
Fenestration Rating Council (AFRC100-2001)
conditions. All Viridian glass performance data
presented in this guide is assessed under AFRC
100-2001 environmental conditions. Care should
be exercised when selecting performance data
to ensure that it meets these criteria.
The code also allows for a dual approach to
calculating glazing system performance either
by reference to published window system
(glass plus frame) data, or by aggregation
of the glass performance data and a frame

Australia
Tropical Temperate Cold

(emphasis (cooling and (emphasis
on cooling)
heating)
on heating)


Zone 1
Zone 2
Zone 3

Zone 4
Zone 5

Zone 6
Zone 7
Zone 8

New Zealand
(cooling and
heating)
Zone 1
Zone 2
Zone 3

The BCA energy efficiency requirements are evolving in stringency and application. The information
on glazing requirements has been paraphrased from the ABCB publication: Regulatory Proposal
Energy Efficiency Measures for Class 5 to 9 Buildings BCA Volume One, November 2004.

Glass and energy


management

Energy

The solar energy spectrum and glass

Solar Heat Gain Coefficient (SHGC)

The role of Viridian solar control glass is to


minimise infrared light that carries most of the
suns solar energy while maximising visible light.
Solar
energy
Reflected
energy
Absorbed
by glass

Direct
transmitted
energy

The ideal spectrally selective glass would transmit


daylight and eliminate infrared and UV light.
The chart below compares some current Viridian
products to the theoretical ideal glass.

Re-radiated
heat

OUTSIDE

INSIDE

How much daylight versus transparency?


For certain applications clear visibility is important,
while for others glare control is necessary. The size
of the glazed area determines the quantity of

Glass controls solar heat gains through reflection


and absorption the sum of the direct solar
Solar control and insulating glass

heat transmitted and the absorbed heat that

Glass controls solar heat gains


through reflection and absorption
the sum of the direct solar heat
transmitted and the absorbed heat
that is re-radiated inside is the total
heat transmitted or the SHGC.

is re-radiated inside is the total heat transmitted


or the SHGC.
The SHGC performance of the example above
could be improved by adding a colour tone
to the glass or by adding a Low E coating.

daylight, not just the glass daylight transmission


percentage. In some cases very low light
transmission glass is required.
For shopfronts, transparency and clarity are
paramount. High daylight transmission glass
with low internal and external reflectivity should
be specified.

. 

For commercial building facades, there is a


trend to maximise transparency and daylight.
High daylight transmission often results in work
spaces that have too much glare. Very low
transmission means more artificial lighting.
Particular care needs to be taken with east
andwest elevations.

. 

For night time viewing, the greater the light


transmission, the easier it is to see out. Highly
reflective solar control coatings are not advised
if night viewing is a priority.

. 

UV

Visible
light

Solar infrared (heat)

For large overhead expanses, glass with


relatively low daylight transmission results in well
balanced, naturally lit spaces. This is particularly
so if a screen printed Viridian Seraphic Design
is combined with a solar control glass.

. 

100
90

% Transmission

80
70
60
50
40
30
20
10
0
0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5

Wavelength um

viridianglass.com

Reducing building
operation costs

Energy

Glass cost versus payback

A well designed glazing system reduces building

High performance solar control and insulating

operation lifecycle costs. The inclusion of optimal

glass is an investment that delivers energy savings

day-lighting allows for significant opportunities

for the life of a building and may determine the

in the reduction of building energy use and can

buildings future energy rating and value. The

be measured in terms of the cost of artificial

additional cost of a solar control or insulating

lighting. It is generally accepted that natural light

facade can be negated by the reduction in the

is beneficial to peoples health and well being,

capital cost of air-conditioning plant.

and can be the foundation for a productive


working environment.

Relative glass cost/m2

Glass cost relatives

Further to this, the selection of a glass with


the most appropriate solar control (solar heat

2.5
2
1.5
1
0.5
0

gain coefficient) and insulation (U Value) can


significantly reduce energy costs in heating and
air-conditioning. This is achieved by placing less
loading on the plant and installing a smaller
Increasing glass performance

Float Toughened
Laminated Double glazing

air-conditioning plant. A better performing


building envelope is achieved with higher
performance glass. The additional cost of
this glass is often offset by a reduction in the
air-conditioning plant cost (illustrated below).

Other considerations:

Thermal stress some solar control glass


requires the additional process of heat
strengthening to prevent breakage from
thermal temperature differentials. At an early
design stage this additional cost can be
reviewed and often avoided. It may be as
simple as changing the frame colour.

. 

Capital cost

$/m2

Glazing size and dimensions by selecting a


module that suits the glass maximum size or
processing equipment (toughening, laminating
or coating) economies can be made. Likewise
minor modifications in glazing may enable
more economical thickness of glass to be
used. For example, glass can resist greater
loads as a square than a rectangle for the
same thickness.

. 

300
250
200
150
100
50
0
Clear SuperGreen Reflective IGUs
Increasing glass performance
 Total Glass HVAC

The chart shows how the investment in a high


performance glass (solar and thermal insulation)
reduces the capital cost of the heating and

Life cycle the environment and payback

air-conditioning plant (HVAC) by delivering

Glass is a material that allows passive day-lighting

equivalent performance. Running costs are

and heating. Used correctly, it can also assist with

reduced and savings continue for the life of the

cooling through the stack effect. These attributes

building, (source Lincoln Scott, Feb 1995).

help to progressively offset the embodied energy


in the manufacture of glass.

Did you know?


By using certain Low E glass
combinations, more than two thirds
of the heat can be eliminated prior
to it entering the building.

viridianglass.com

Solar control, thermal insulation


and energy management

Energy

Energy management is a key decision in

direct solar radiation to pass through the glass

Solar control products

determining the performance and appearance of

and then traps it inside. So in combination with

building facades. This section outlines the various

the correct selection of solar control or thermal

Solar control Products that mediate


solar heat gain

attributes and performances of Viridian glass.

insulation glass, EnergyTech and SolTech reduce

. 

energy use.

. 

Products have been grouped by their


keyapplication:
Solar control

. 

Low E glass
These glasses enhance insulation, and provide

Solar control with Low E

additional solar control when combined with

Thermal insulation

a solar control glass, in either a single glass,

. 
. 

Terminology
To describe the performance of glass, it is
important to understand the following attributes.
Visible light transmittance the percentage
of visible light transmitted through the glass.
The higher the number, the more light. It does
not determine the colour of the glass.

. 

SHGC (solar heat gain coefficient) the


proportion of directly transmitted and absorbed
solar energy that enters into the buildings
interior. The lower the number, the better solar
control. For example, if the direct solar energy
on a hot day is 785 watts/m2 and Viridian
SuperGreen was used with a SHGC of 0.51,
then the solar energy reaching indoors is
785 x 0.51 = 400 watts. Approximately half
of the suns heat is eliminated.

. 

U Value this is the measurement of air-to-air


thermal conductance, or insulation between
indoors and outdoors, through the glass.
The lower the number, the better the insulation.
For example, clear glass has a U Value of
5.8 W/m2 C. If the indoor temperature was
24C and the external temperature 34C
(adifference of 10C) then 10C multiplied by
the U Value 5.8 equals 58 watts/m2 of heat
thatwould be transferred between the exterior
and interior.

Emissivity measures the rate a product emits


absorbed heat. The lower the number, the more
efficiently the glass reduces heat gain or heat
loss, which means a lower U Value and better

Low E glass has either a pyrolitic or Airco coating

. 

that reduces the emissivity of the glass surface.

. 

This means the glass provides greater insulation

. 

by reflecting heat. For improved solar control it

. 

is also a second line of defence. Heat absorbed

Thermal insulation Insulating glass


units for cold and hot conditions

SmartGlass

by the solar control glass is reflected back out


by the Low-Emissivity coating to provide even
better solar control. Low E coatings are useful for

To assist in comparing products, Viridian


has developed a chart that shows the key
performance selection criteria: daylight, solar
control and insulation (chart below).
Performance comparison
Comparison chart
Chart
Product*

Insulation

Solar

Daylight

VFloat Clear

5.8

0.82

88

SuperGreen

5.8

0.52

67

EVantage
SuperGreen

3.8

0.37

49

6mm glass thickness.

This example shows a comparison between


VFloat Clear, SuperGreen and EVantage
SuperGreen.
The greater the shaded area, the better
performance. The number represents the actual
value for:
Daylight = % transmission

emissivity of 0.84 and EnergyTech and SolTech


is 0.17, which means only 17% of heat absorbed

. 

buildings that require passive heat gains, it allows

SolTech
EVantage
ComfortPlus

ThermoTech IGUs

. 

PerformaTech

. 

Thermal breakage

Performance comparison

. 

in the glass, passing to inside the building. For

EnergyTech

reducing solar heat gains and also heat loss.

. 

used, it acts as a barrier to the absorbed heat

Solar control with Low E Products that


provide high solar control, with the
added insulation of a Low E coating
. 

insulation. For comparison, normal glass has an

is re-emitted. Likewise, if a solar control glass is

High performance tones


SuperGreen
SuperGrey
SuperBlue

a laminate, and/or an insulating glass unit.

. 

What is Low-Emissivity?

VFloat

Solar = Solar heat gain coefficient


Insulation = U Value

The full performance data of all products is shown


in the performance data table at the back of
this guide.

Thermal breakage refers to annealed


glass cracking due to a build up
of excessive thermal stress from a
differential in temperature gradient
across the glass. Viridian recommends
that a thermal stress analysis be
undertaken for all solar control glazing.
This is a free service for all trading
Viridian customers only. If a glass
is unsafe then it will require heat
strengthening or toughening. Normal
annealed float glass can resist a
temperature differential of 40C;
DcorPatterned glass and wired glass
30C; heat strengthened glass 180C
and toughened glass 250C.
There are many factors that affect
thermal stress, the higher the solar
absorption of the glass, the more risk.
Factors such as shading from frame
depth or shading devices, the type
and colour of the frame, whether or not
there is a back up wall or blinds, the
colour of the blinds or wall, the distance
of the blinds or wall to the glass and
whether or not the gap is ventilated,
all affect stress. Modification of any of
these factors will impact on the thermal
breakage of the glass.

viridianglass.com

For colour, excellent solar


performance and comfort, this
advanced toned glass is a natural
These super toned glasses provide significant

Thermal safety

improvements in solar performance compared

The high performance toned glass range absorbs

to VFloat toned glass. The colours are deeper,

a large proportion of solar radiation. Applications

however natural views from the interior are

must be checked for thermal stress breakage.

maintained with low-exterior reflectance. They

We recommend that VFloat SuperGrey be

are readily available and can be processed

specified and supplied as a heat strengthened

and fabricated similarly to normal float glass to

ortoughened glass in all situations.

provide an economical choice for reducing


air-conditioning costs.

Energy
SuperGreen
SuperGrey
SuperBlue

Features and benefits


High solar control float glass low cost glass
without coatings optimises light transmission
and reduces cooling loads.

. 

Viridian VFloat SuperGreen


SuperGreen provides a deep green, crisp
appearance with sharp clean external views

Low reflectance
Low external and internal reflectance.
VFloat SuperGreen and Viridian VFloat
SuperBlue provide good daylight transmission.

. 

andlow-external reflectance.
Designed to provide very high daylight
transmission (66%) with solar control (SHGC of

Low UV transmittance outperforms other tinted


products for reduced fading. Viridian VFloat
SuperGrey eliminates 99% of UV radiation.

Applications
Where deep green,
blue or grey colour is required

. 

. 

0.51). It offers 20% better solar performance than


conventional tones, with reduced glare and UV.

Low and medium size


office buildings

Residential

Use in Viridian ThermoTech (insulating


glass units) can be combined with Low E
glass in insulating glass units for enhanced
performance.

. 

Viridian VFloat SuperGrey


Provides the highest solar control of any uncoated
float glass, with solar control (SHGC of 0.35).

Hotels

Maximum size
VFloat SuperBlue, SuperGrey
5180 x 3302mm

. 

Its dark grey colour provides privacy from the

SuperGreen
5100 x 3210mm

outside and reduced see-through. The glass


reduces glare with 9% light transmittance

How to specify

making it appropriate for use in skylights or near

Select glass name


Viridian SuperGreen, SuperGrey
and SuperBlue

. 

computer monitors.
Viridian VFloat SuperBlue

Select thickness process


3mm to 10mm Annealed
4mm to 10mm Toughened
4mm to 10mm Heat Strengthened
6.38mm to 21.52mm Laminated
9.52mm to 21.52mm
Toughened/Laminate

. 

A unique blue colour that is cool and distinctive.


It provides solar control similar to that of
SuperGreen, again with high daylight transmission.

Select colour
Refer to chart below

. 

Performance comparison chart


Product*

Product range

Insulation

Solar

Daylight

SuperGreen

5.8

0.52

67

SuperGrey

5.8

0.35

Product

SuperBlue

5.8

0.52

53

SuperGreen

6mm glass thickness.

The bar chart diagram is for indication only, for performance


data please refer to the glass performance data tables
at the end of this document.

Thickness (mm)

SuperGreen N

10

SuperGrey

SuperBlue

viridianglass.com

Superior ways of managing


the internal environment
Developed in Australasia for our environmental
conditions and energy efficiency measures

Viridian Low E glass the foundation for better


solar control and insulation

The Viridian Solar Control with Low E range

Viridian uses the latest advances in coating

provides excellent solar control with higher

technology to vary the solar transmission

insulation than standard glass. They are a

component of the Low E coating for each

combination of solar control glass and coatings

product range. The unique properties of

with the option of additional solar control

Low E coatings allow the glass to retain very high

interlayers. This glass range is designed for

daylight transmission and act as a barrier to the

applications where high daylight transmission is

absorbed heat in the glass, reflecting it outside

required without reflectivity plus moderate to high

for better solar control.

solar control and insulation to reduce heat loss.


Recognised as a simple and effective solution
tobalancing design objectives with Energy
Coderequirements.

Energy
Solar Control
with Low E

Further to this, the Low E coating increases


insulation by reflecting heat from inside the
building back into the building to reduce energy
loss through the glass. The increase in insulation

Multi-function glass combinations

from the Low E coating is not an option to prevent

The Viridian Low E range is not just limited to

surface condensation, in these situations Viridian

the standard products listed it can be further

ThermoTech should be considered.

processed to include:

Whilst PerformaTech can only be supplied as

Products
SmartGlass
Affordable, residential energy
efficient glass

. 

Viridian Renew self cleaning glass

part of fully encapsulated Viridian ThermoTech

. 

Thicker interlayers for additional security


and strength

IGU, other products in the range can be glazed

. 

monolithically or as a laminate, with the coating

. 

Improved noise control by incorporating


special noise reducing interlayers

facing the inside of the building only.

. 
. 

. 

Monolitic Low E options can only be glazed as


part of the building envelope with the coated
surface to the interior.
When the product is supplied with the coating
glazed to the inside of the building, the presence
of the coating may be detected as it possesses a
different appearance and surface characteristics
to uncoated glass.
If the relevant product within the range is glazed
with the coating exposed to the inside of the
building, whilst the coating is very durable,
specific handling and cleaning instructions do
apply. In such circumstances please refer to the
cleaning section on the Viridian website.
Low E coated products exhibit a natural haze
characteristic which may be noticeable when
the glass is in direct sun or viewed against a dark
background. This is not a fault with the glass but
simply a characteristic of the Low E coating.

EnergyTech
SolTech
EVantage
Solar control Low E on toned
glass substrates
ComfortPlus
Low E laminated glass

. 

EnviroShield Performance
 Incorporates an additional high
performance solar control interlayer
for outstanding solar control and
daylight transmission. This range
also incorporates other customised
performance laminates

. 

ThermoTech
A range of double glazed units
(insulated glass units) that offer
improved insulation

. 

PerformaTech
A new addition to the Viridian Energy
glass range providing an exceptional
balance of high light transmission,
low SHGC and very low U values

. 

viridianglass.com

Affordable energy efficient glass


with active insulation technology
Description

Features and Benefits

SmartGlass is a range of single glazed toughenable

. 

Energy

Low E insulation with a choice of solar protection


performance for residential applications

Low E products offering insulation and a choice of

SmartGlass

Provides a straight forward energy efficient


alternative to ordinary glass

. 

solar protection, with low reflectivity ideally suited to


the demands of Australian residential applications.

Low E
coating

Durable pyrolytic Low E coating ideal for


single glazing

. 

SmartGlass provides excellent performance and


versatility for single glazed windows.

Reduces
solar heat in
summer

Low reflectivity

. 

SmartGlass has been selected for Australian

. 

climate conditions to assist in achieving energy

. 

Can be toughened for Grade A Safety glass

Reflects
warmth back
inside in winter

Suitable for most standard single glazed


window frames

Star Ratings for home designs, whilst still capturing


natural light and views. Manufactured using
hardcoat Low E coating for excellent durability
and ease of processing and handling.

Sp1

IR_2011-02-23_0154.jpg

35.3C

SmartGlass

Ordinary glass

Reflects heat back


into the room

Allows heat to
escape outside
Applications
New homes

. 

Residential renovations

. 

Replacement and retrofit glazing

. 

Maximum sizes
As you can see in this actual thermal
image, SmartGlass reflects heat back into
the room, helping keep occupants warm
when its cold outside.
Compare this to the ordinary glass window,
where heat freely escapes to the outside.

Sp1

Product
Value

Parameters
30.5C

Image
Max
MinSmartGlass
4mm

51.5C

Visible
trans.
%

23.2C

SP10 Clear Polaris

Visible temperature:
Visible
Atmospheric

Solar
28,7

Relative
humidity:
(external)
(internal)

0,57
%

Transmission:

0,98

reflect.%

reflect.%

Refl. apparent temp.:

83

SP30 Neutral Panoramic

61

SP35 Grey Dusk

50

Distance:

11
Emissivity:

11

trans.

Solar
reflect.
%

UV
trans.
%

U Value
(W/m2C)

11

54

3.7

SHGC

Shading
coeff.

External optics temperature: 37,4

0.72

10

46

44

3.7

0.53

0.62

45

21

3.7

0.53

0.62

How to specify
Select glass name
SmartGlass

. 

Select thickness process


4 or 6mm annealed
4 or 6mm toughened
Select colour
Refer to product range chart

0.83

External optics transmission:

SP35 Grey 5100 x 3210mm

. 

. 

29,8

68
0,94

SP30 Neutral 5100 x 3210mm

. 

. 

25.4C

Performance data

SP10 Clear 5100 x 3210mm

. 

Product range
Thickness (mm)

6mm SmartGlass

SP10 Clear Polaris

81

11

12

65

10

48

3.6

0.69

Product

0.80

SP10 Clear

SP30 Neutral Panoramic

63

10

45

41

3.7

0.53

0.62

SP30 Neutral

SP35 Grey Dusk

40

37

16

3.7

0.47

0.55

SP35 Grey

Made with a FLIR ThermaCAM B660 West

Energy
EnergyTech
SolTech

Viridian EnergyTech
and SolTech Low E
The foundation for better insulation and
solar control

Description

The comprehensive range of Viridian EnergyTech

feature a pyrolytic Low Emissivity coating that is

and Viridian SolTech Low E products offer

fused at extremely high temperature when the

improved thermal insulation and a choice of solar

glass is being made, producing a durable hard

control performance with low visible light reflection.

transparent coating on one surface of the glass.

The range is designed for Australian climate

Unlike ordinary float glass, the Low E coating

regions and to help meet energy requirements.

provides better insulation and enhanced solar

Being a local manufacturer, Viridian understands

control to help keep a building warmer in winter

our climate is unlike that of Northern Europe or the

and cooler in summer. The application of the

United States. Thats why we offer a comprehensive

SolTech and EnergyTech Low Emissivity coating to

choice of Solar Control Low E products to help

the glass improves their thermal insulation (U-Value)

reduce the extremes of Australias warmer weather,

and also further reduces the solar heat gain

balanced with opportunities for passive solar

(SHGC) by inhibiting inward transmission of the solar

heating.

energy absorbed by the glass, whilst still providing

Our range has been expanded to include a

good daylighting performance.

choice of performance and colours, including

The range also offers low internal and external

greys, greens, neutral and clear to satisfy different

visible reflectivity, typically desirable in residential

designs objectives. Using the durable pyrolytic

buildings and commercial buildings when

hard coat technology enables the Low E coating

transparency is valued. If higher visible light

to be single glazed and exposed to the interior of

reflectivity is desired then the Viridian EVantage

a building to provide improved thermal insulation.

pyrolytic Low E products offers a range of choices.

The products can also be used as part of a


laminated glass or in an insulated glass unit.

The Viridian SolTech and EnergyTech range

Considerations
Please note the presence of haze may be
perceived under certain light conditions.
When single glazed these products are not
designed to prevent surface condensation and
their insulating capacity is reduced should this
occur. Viridian ThermoTech Insulating Glass Units
are recommended in these situations.

viridianglass.com

Energy
Performance Comparison Chart

suns warmth to enter a building, capturing it inside

The comparison illustrates the performance of the

and then reducing heat loss. In contrast SolTech

product range in relation to:

Grey which has a low SHGC is designed to reduce

Insulation the products U-Value

solar gain by providing the highest solar control of

Solar Control the products solar heat


gain coefficient

improved insulation and a choice of solar control,

EnergyTech
SolTech

the range. The range of products whilst providing


continue to offer good daylight transmission to

Daylight visible light transmission as


a percentage

encourage natural lighting of buildings.

The chart helps to show the breadth of the range,


with products that offer passive solar heating in
cooler climates; a balance of solar control and
insulation in mixed climates or higher solar control
for hotter climates and demanding orientations.
For example EnergyTech Clear, which has the
lowest solar control (highest SHGC), is designed to
assist with passive solar heating by enabling the

Features & Benefits


T hermal insulation: Low E coating provides
enhanced thermal insulation by lowering
the U Value of the glass
S olar Control: A broad range of solar
control performance to choose from
for Australian conditions
 aylighting: Provides a choice of good
D
visible day lighting to reduce the need
for interior lighting
Low Visible Reflectivity: Low visible light
reflectivity to provide good transparency
 yroltic coating: Durable hard coating bonded
P
to the glass to provide excellent shelf life and
can be used single glazed with the coating
exposed to the interior of building
Easy processing: Can be toughened,
laminated, curved or used in an insulated
glass unit

Applications
Single glazing

. 

Can be laminated

. 

Used in IGUs to enhance


performance

. 

Residential & commercial buildings

. 

Retrofit glazing

. 

Maximum size
EnergyTech Clear

5100 x 3210mm

EnergyTech Green

5100 x 3210mm

EnergyTech Grey

5100 x 3210mm

EnergyTech SuperGreen 5100 x 3210mm


SolTech Neutral

5180 x 3302mm

SolTech Grey

5100 x 3210mm

How to specify
Select glass name
Viridian EnergyTech
Viridian SolTech

. 

No edge deletion: Does not require edge


deletion for use in insulated glass units

Select colour
Refer to product range below

. 

Select thickness and process


Annealed, toughened,
heat strengthened

. 

Performance comparison chart


Single Glazing
Product

Insulated Glass Units

Insulation

Solar

Solar

Daylight

EnergyTech Clear

3.6

0.69

81

1.6

0.61

73

SolTech Neutral

3.7

0.53

63

1.6

0.45

56

EnergyTech Green
EnergyTech Grey
EnergyTech SuperGreen

3.7
3.7
3.7

0.49
0.47
0.40

Daylight Insulation

71
40
61

1.6
1.7
1.6

0.41
0.39
0.32

63
35
54

Product range
Thickness (mm)
Product

EnergyTech Clear

EnergyTech Clear N

EnergyTech Green

EnergyTech Grey

Performance data is for glass only and not suitable for NCC Section J calculations. Data compares
performance of 6mm thickness for single glazed and IGUs are argon gas filled with 12mm width.

EnergyTech Supergreen

The bar chart diagram is for indication only, for performance data please refer to the glass
performance data tables at the end of this document.

SolTech Grey

SolTech Grey

3.7

0.36

30

1.6

0.28

27

SolTech Neutral

10

viridianglass.com

Providing thermal and solar


control enhancements
Viridian EVantage is designedfor buildings that

Features and benefits

require high level solar control and the insulating

. 

benefits of a Low E coating.

. 

Description
EVantage is an economical option for projects
that require glazing alternatives better than

insulating glass units and solar control laminates.


EVantage is manufactured by the pyrolitic low E

Good light transmission with subtle reflectivity


Short lead times

. 

Lower UV transmittance*
Used in Viridian ThermoTech insulating glass
units for enhanced performance

. 

Neutral light transmittance maintains toned


glass colour and clarity

. 

The durable pyrolitic coating means that


Viridian EVantage can be cut and processed,
toughened, laminated,** curved or fabricated
into insulating glass units

. 

deposition process, a gas reacts with the semi

Warranty, refer to page 122

thermal performance, subtle reflectivity and glare


control. The base colour of the glass whether
clear, grey or bronze, Viridian SuperGreen or

* When compared to 6mm clear glass


** The clear glass on the composite used for
laminated Evantage, will slightly vary the external
aesthetic of the toned range. Samples are
available from Viridian if required.
Performance comparison chart

the proprietary Low E coating.

EVantage

thermal and solar control enhancements. The


placement of air-conditioning vents adjacent to
and directed on the internal glass surface coating,
may reduce the performance of EVantage when
used in a single glazed installation.

Office buildings

. 

Institutional and social buildings

. 

Hotels

boost to solar and thermal characteristics through

The Viridian EVantage Low E coating provides

Where high solar control and


insulation are required in
buildings such as apartments,
lightcommercial, retirement and
health care facilities

. 

Viridian SuperBlue is maintained with a significant

Product selection

Applications
. 

. 

reflective coating on clear and toned substrates.


The result is a product that combines solar and

EVantage provides Low-Emissivity


qualities with solar control.

. 

coating process. In this online chemical vapour


molten surface of the float glass to form a

EVantage

Solar control with a Low E

standard glass and that in the past have had


to specify top of the range high performance

Energy

Clear

Maximum sizes

Insulation

Solar

Daylight

. 

3.8

0.63

68

. 

3300 x 2440mm
5100 x 3210mm

Bronze

3.8

0.45

38

How to specify

BlueGreen

3.8

0.45

56

. 

Grey

3.8

0.41

32

SuperGreen

3.8

0.37

49

SuperBlue

3.8

0.36

39

6mm glass thickness.

Select glass name


Viridian EVantage

Select thickness process


6mm Annealed
6mm Toughened
6mm Heat Strengthened
10.38mm to 13.52mm Laminated
11.52mm to 13.52mm
Toughened/Laminate

. 

Select colour
Refer to product range chart

. 

Product range
Thickness (mm)
Product

10.38

12.38

Grey

Bronze

BlueGreen

Clear

SuperGreen

SuperBlue

viridianglass.com

Energy efficiency without


compromising your views

Energy

ComfortPlus has long been recognised as

Please note that the presence of haze may be

Australasias leading Low E performance laminate.

perceived under certain lighting conditions.

Initially ComfortPlus was designed asa residential


range of Low E laminates. Over time, ComfortPlus
has been used increasingly incommercial
applications.

Features and benefits


ComfortPlus is a laminated safety glass for use in
windows and doors that form part of the building
fabric, available in clear, neutral, grey, green or

The Viridian ComfortPlus range has been

translucent, and is manufactured with a permanent

expanded, with more products to choose from.

transparent coating which must be glazed to the

Within the Low E laminate range, ComfortPlus is

inside of the building. As with all monolithic Low E

a high performance glass solution that can be

products, it is not appropriated that ComfortPlus

used to maximise a buildings glazing potential

be used where the coated surface is permanently

by bringing in the outside world while complying


with the Building Codes provisions for energy

exposed to the exterior.


Summer and winter performance through
the unique combination of solar control glass
and coating.

Description

transparency and high performance solar control

High daylight transmission up to 76%.


Solar control up to 70% of solar heat
transmission is eliminated.

. 

Thermal insulation a 30% improvement in


U Value over standard glass means less heat
is transmitted.

. 

with low reflection. Equally, it economically


manages the heat of summer and the cold of
winter. It incorporates a solar control component

Fading reduction ComfortPlus reduces


UV radiation by 99%, increasing the life of
furnishings by 8.5 times.

. 

that in summer reduces the suns heating, glare


and UV fading of interior furnishings. In winter, the
ComfortPlus coating provides thermal insulation
and reduces heat loss through the glass by over
30% when compared to standard glass, without
heavy tinting or reflective mirror-like coatings that
reduce natural light.
Considerations
ComfortPlus is not designed to prevent surface
condensation and its insulating capacity is
reduced should this occur. Viridian ThermoTech
is recommended in these situations (refer to
page 45).
ComfortPlus Clear 82 is designed for cold

S afety ComfortPlus is a Grade A safety glass.


It reduces the potential for injury and if broken
remains in place.
Noise the ComfortPlus laminate reduces voice
noise by 13% and traffic noise by 24% when
compared to standard 3mm glass. Sun glare
can be reduced by using ComfortPlus Grey 40.

. 

Self cleaning can be combined with Renew


self cleaning glass.

. 

Security thicker interlayers are available for


increased resistance to physical attack.

. 

Privacy ComfortPlus Translucent addresses the


concerns for privacy of homeowners, providing
a solution for overlooking.

. 

Cleaning, refer to page 121.

climates. The ComfortPlus range features a

. 

selection of colours, daylight transmission and

. 

Warranty, refer to page 122.

solar performance with low-external reflectivity


similar to that of standard float glass.

Performance comparison chart


ComfortPlus

Samples should be viewed by designers and


building energy professionals consulted for
suitability. Where colour consistency is important
only use one thickness. For large projects, please
consult with Viridian.
The placement of air-conditioning vents adjacent to
and directed on the internal glass surface coating,
may reduce the performance of the product.

Apartments

. 

Retail

. 

Office buildings
Institutional and social buildings

. 

Hotels

. 

Where solar control and insulation are


required in a single glass, ComfortPlus
provides excellent daylight
transmission and low reflection for
houses and
apartments

. 

. 

has been developed to meet objectives of

Applications

. 

. 

efficiency.

The ComfortPlus range of laminated glass

ComfortPlus

Insulation

Solar

Daylight

Clear 82

3.6

0.68

82

Neutral 59

3.6

0.51

59

Green 71

3.6

0.50

71

Grey 40

3.6

0.50

39

Translucent

3.6

0.56

62

For comprehensive performance comparison data refer to page 125.

Maximum size
3660 x 2440mm

. 

5100 x 3210mm

. 

How to specify
Select glass name
Viridian ComfortPlus

. 

Select thickness process


6.38mm to 17.52mm Laminated
7.52mm to 17.52mm
Toughened/Laminate

. 

Select colour
Refer to product range chart below

. 

Product range
Thickness (mm)
6.38

8.38

Clear 82

Neutral 59

Green 71

Grey 40

Translucent

Product

10.38 12.38

*Note: Colour variation may be


apparent in differing thicknesses.
Not all thicknesses available to
5100 x 3210mm.
Thermal assessment may be
required for ComfortPlus.

viridianglass.com

Providing solar control, insulation


and privacy in a single glass
ComfortPlus Translucent represents an

Obscure glass, such as ComfortPlus Translucent,

extension to the ComfortPlus range. The product

is provided as an option for addressing overlooking

combines the benefits of solar control, insulation

issues in compliance to building regulations.

and privacy. Initially ComfortPlus was designed

Energy
ComfortPlus
Translucent

Features and benefits

asa residential range of Low E laminates. Over

Obscure glass providing privacy and


performance benefits of Low E glass

. 

time, ComfortPlus has been used increasingly


incommercial applications.

Provides access to natural light where


overlooking design considerations may
prevent the use of a clear glass

. 

Description
The trend towards greater urban density and infill

Now part of standard product range,


making it easier to specify and purchase

. 

housing developments is driving demand for


building products that help address the concerns

Grade A Safety Glass as standard

. 

for privacy and overlooking issues.

Blocks 99% of unwanted UV light

. 

Overlooking is an important consideration when

Applications
Apartments

. 

Retail

. 

building or renovating. Its where the living space

. 

of one property overlooks the living space of

. 

another property.

. 

Office buildings
Institutional and social buildings
Hotels
Where solar control, insulation and
privacy are required in a single glass

. 

Maximum size
3660 x 2440mm

. 

How to specify
Select glass name
Viridian ComfortPlus Translucent

. 

Select thickness process


6.38mm or 10.38mm

. 

Performance comparison chart


Product
6.38mm ComfortPlus

TM

Translucent

10.38mm ComfortPlusTM Translucent

Insulation

Solar

Daylight

3.6

0.56

62

3.6

0.53

60

Product range
Thickness (mm)
Product
Translucent

6.38
.

8.38

10.38 12.38
.

viridianglass.com

Increasing solar control without


sacrificing daylight transmission

Energy

Creating an environment rich in natural light

EnviroShield Performance ITO adds a solar

whilst dealing with the broader issues of energy

control interlayer to the laminate that has been

efficiency has long been the challenge of building

specifically engineered for Australian conditions.

designers. With the development of building code

It is a world first and a unique product offering

changes encouraging energy efficient design

that assists with the demands of modern building

and growing consumer awareness, this challenge

design. The attributes of EnviroShield Performance

has never been greater.

ITO are greater solar control with minimal

Traditionally large areas of glass are desirable


in building facades but can negatively affect
a buildings solar and thermal performance;
outcomes not favourable to green construction.

reduction in daylight transmission. EnviroShield


Performance ITO Clear offers the highest light
transmission solar control product in the Viridian
range. It eliminates 50% of solar heat gain. This
product has been developed for designers who

The introduction of performance interlayers

want the appearance of clear glass with medium

providing energy efficient glass products has

performance solar control in applications such as

enabled Viridian to counter these concerns,

retail entrances.

allowing the freedom to create visually appealing


structures with maximum visible daylight and
low-energy consumption. There are various
products that deal with the issues of minimising
energy; fewhowever, are as versatile as Viridian
EnviroShield Performance.
There are two product groups that fall within

. 

Solar control up to 70% of solar heat


transmission is eliminated.

. 

Thermal insulation a 30% improvement in


UValue over standard glass. This is beneficial
inboth hot and cold climates.

. 

single glazed offering from Viridian.

Atriums

. 

. 

99% UV eliminated for excellent fading protection.

. 

transmission and is the highest performance

Sporting facilities

. 

performance interlayers are ITO and XIR 71.

increases solar control without sacrificing daylight

Large facades

High daylight transmission up to 75%.

. 

. 

Viridian EnviroShield Performance ITO

Applications

Features and benefits

the EnviroShield Performance range. These

ITO

transmission, low reflectivity and high


performance solar control are qualities that
make EnviroShield Performance ITO uniquely
suited to Australasian environmental and design
requirements. The coating technology combines
high levels of solar control and thermal insulation
in a laminated glass, without heavy tinting
or reflective mirror-like coatings that reduce
natural light.

Libraries
Skylights

. 

Museums

. 

Shop fronts

. 

Noise reduction thicker glass and interlayer


combinations are available to achieve high
noise reductions.

Maximum size

Safety EnviroShield Performance ITO is a


Grade A laminated safety glass (AS/NZS2208)
and can be used in areas where human safety
is paramount, such as overhead glazing.

How to specify

. 

Self cleaning can be combined with Renew


self cleaning glass.

. 

The combination of transparency, daylight

EnviroShield
Performance ITO

Security thicker interlayers are available


for increased resistance to physical attack.

. 

3660 x 2440mm

. 

Select glass name


Viridian EnviroShield
Performance ITO

. 

Select thickness process


8.76mm to 17.52mm

. 

Select colour
Refer to performance
comparison chart

. 

Warranty, refer to page 122.

. 

Performance comparison chart


EnviroShield Performance
Product*

Insulation

Solar

ITO Clear 74

3.6

0.54

Daylight
75

ITO Green 67

3.6

0.45

69

ITO Neutral 54

3.6

0.44

56

ITO Grey 33

3.6

0.35

35

ITO SuperGreen 45

3.6

0.34

46

ITO SuperBlue 40

3.6

0.31

34

For comprehensive performance comparison data refer to page 129.

Note: Thermal assessment may be


required for Enviroshield Performance.

viridianglass.com

Incorporating a performance
interlayer to further enhance
solar control
Maximum daylight with minimum energy

The universal appeal of XIR remains its maximum

consumption, Viridian EnviroShield Performance

performance in a colour neutral product. It can

XIR 71 is a highly specialised glass product. This

however be further enhanced when combined

film is encapsulated in a laminated glass creating

with other products from the Viridian range,

a colour neutral, energy efficient product with

such as EVantage or SolTech.

exceptional solar control properties. XIR rates in


the top end for solar control glass products and
has the key benefits of an exceptionally high
light-transmission of 73% whilst offering superior
reduction in solar heat gain (0.50 solar heat gain
coefficient). This is comparable and in many
cases superior, to the higher end heavily tinted or
reflective solar control products. The real beauty
of Viridian EnviroShield Performance XIR is that
it is colour neutral whilst offering outstanding
protection against solar heat gain.

benefit of reducing heat loss is made possible


by combining the XIR film with high performance
body tints and Low E pyrolitic coated glasses. In
addition, the broader aspects of design, colour,
structural integrity and noise attenuation can be
addressed. Combined with our unique oversize
manufacturing capabilities, these provide
endless solutions for high end designer projects.
EnviroShield Performance combined with Viridians
superior expertise and manufacturing capabilities
can help you achieve a solution as individual as

expanses of glass and light without compromising

your design.

Performance XIR is ideally used in all types of

EnviroShield
Performance XIR

Solar control can be improved and the additional

This allows architects the freedom to use large


cooling loads and visual clarity. EnviroShield

Energy

Benefits
Improved daylight, with 73% light
transmission

. 

Increased comfort, with lower


heating costs 0.47 Solar Heat
GainCoefficient

. 

Improved transparency on both


interior and exterior surfaces.
This is not possible when using
acoated glass product

. 

Available in cut to size only

glass facades, either structural or non structural,

. 

glass roofs, showrooms, atriums, sporting facilities,

. 

and basically anywhere where solar control is

. 

required without sacrificing natural daylight.

Maximum width 1980mm


Black edge sealant is applied
to all edges
Available as a laminate,
toughenedlaminate and
a laminatein an IGU

. 

Outside noise reduced

. 

How to specify
Select glass name
Viridian EnviroShield Performance XIR

. 

Select thickness process


8.76mm to 17.52mm Laminated
7.52mm to 21.52mm
Toughened/Laminate

. 

Select your performance


Refer to performance data on
page 124. For other performance
levels, contact Viridian.

. 

Note: Solvent manufactures directions


and warnings must be followed at all times
and care should be taken to avoid contact
with glazing sealants or other materials
that may be affected by such. In no case
should razor blades, scrappers, scourers or
other metallic or abrasive objects be used
on the product surface.
Not suitable for exposed edges.

Energy
LightBridge

Creating a seamless bridge


between inside and out
Viridian LightBridge double glazing creates a

Description

seamless bridge between inside and out, allowing

LightBridge is a range of high performance

us to bring into our daily lives the light, space and

insulating glass units (IGU) developed specifically

colours of nature. LightBridge offers a market-

for residential building applications. Constructed

leading combination of insulation, security and

with low-e glass and inert gas fill as standard, a

noise reduction properties for domestic windows,

high insulating factor is assured, whilst maintaining

which means we can easily achieve the expansive

a very high level of visual clarity and visible

glazing we desire to bathe our homes in natural

light transmission levels. It is configured for three

light and reconnect with the world around us.

standard make-ups:
Base Product an IGU with two monolithic lites

. 

(toughened or annealed).
Sanctuary Level 1 one lite replaced with a

. 

standard laminate.
Sanctuary Level 2 one lite replaced with an

. 

Applications
.

Residential windows and doors

Size Limits
.

Minimum size* 350mm x 250mm

Maximum size* 2500mm x 2000mm

Note that the limiting glass thickness


is 5mm toughened, hence the
maximum unit area permissible
under AS1288 is 4.5m2

acoustic laminate.
*Spacer width can vary between 8mm and 20mm
to meet the needs of the frame / specification.
Applications
LightBridge insulated glass units are for use in fully
framed windows and doors in detached residential
and low-rise multi-residential building projects. The
product is specifically designed to improve energy

*Sizes outside of these limits may be


available as a special order, on request.

efficiency and/or increase the permissible glazed

Glass Options

natural light within the property.

area of the design, thereby increasing access to

LightBridge is available in base


makeup, and two levels of
Sanctuary upgrade

Four standard colour / privacy


combinations are available: Clear,
Grey, Translucent, Translucent Grey

windows and doors capable of taking a

The limiting glass width is 4mm or


5mm, available in annealed or
toughened, which is paired with
various glass thicknesses
depending on colour and
Sanctuary level selected

The product may also be suitable for fully framed

viridianglass.com

The standard makeups of LightBridge are suitable


for most common configurations of residential
doubleglazed unit.

roof, skylight and other elevated or sloped glazing,


provided that the selected makeup is compliant
with AS1288.

Energy
Considerations
The width of the spacer and the glass

. 

typeselected will influence the U-value achieved


Grey variants should be considered for windowsin

. 

Features and benefits


Exceptionally low U-value (high insulation factor)
for a residential glazing product
Balance of high light transmission with mid-range

. 

hot climates, sun-exposed elevations, and

solar control. Solar control can be stepped-up

applications subject to high glare

through the use of grey or translucent outer lites

Thermal assessment may be required for lower

. 

SHGC variants
Privacy variants should be considered for

. 

bathrooms, bedrooms, windows adjacent to


public areas and those subject to overlooking

LightBridge

. 

in the make-up, making the product suitable for


all Australian climates
Fully supported by the Viridian product

. 

warranty program
All components locally stocked, and IGUs

. 

locally manufactured for short lead times and


reliable supply
Available in several levels of enhanced security,

. 

How to specify

UV, and noise control

Performance comparision chart


LightBridge Base Level

VT

U-Value

SHGC

LightBridge Clear

79

1.37

0.58

LightBridge Grey

49

1.37

0.40

LightBridge DecorSatin

79

1.37

0.58

LightBridge DecorSatin Grey

49

1.37

0.40

LightBridge Clear +S1

78

1.36

0.53

LightBridge Grey + S1

37

1.36

0.34

LightBridge Translucent + S1

59

1.36

0.43

LightBridge Translucent Grey + S1

37

1.36

0.32

LightBridge Clear +S2

77

1.35

0.53

LightBridge Grey + S2

48

1.36

0.37

LightBridge Sanctuary 1

LightBridge Sanctuary 2

* Above performance data applicable to Low E glass on surface #3


* Above performance data is based on 4mm Low E glass with 12mm Argon in all cases

Select glass name


LightBridge


Select the Sanctuary level
Base (no acoustic security
enhancement);
S1 (UV control plus mid-range
security and acoustic control);
S2 (UV control plus highest security
and acoustic control)


Select limiting colour and
translucency
for solar control and privacy
Clear, Grey, Translucent Clear,
Translucent Grey

Select thickness process


4mm or 5mm, annealed
or toughened


Select spacer width
8mm to 20mm

S pecify the makeup


e.g. LightBridge S2 Clear - 4T:12:6.5

Energy
ThermoTech

Applications
.

Point fixed IGUs applications refer


to Structural section on page 90 for
more information

Maximum energy savings,


superior interior comfort
Glass plays an increasingly important role as

Thermoplastic Spacer TPS

building regulations place great emphasis on

TPS is a butyl-based thermoplastic material. It is

saving energy in both residential and commercial

UV stable with integrated desiccant and applied

designs. The selection of increased thermal

directly onto the glass by a computer-controlled

insulation, or glass with a lower U Value, combined

nozzle. This non-metallic spacer offers the

with solar control, is an important decision in

ultimate heat insulation. In itself, it is an effective

a building envelopes thermal performance.

gas and moisture barrier. Units are supplied with

Viridian ThermoTech is a range of sealed

polysulphide secondary seal as standard. The

insulating glass units that offer improved

space is filled with argon gas as standard which

insulation. For example: by incorporating Viridian

further enhances the performance of the unit.

EnergyTech, a Low-Emissivity (Low E) glass for

Combine it with a silicone secondary seal and it

greater thermal insulation, ThermoTech decreases

is perfectly suited for structural glazing. Structural

heat conduction between outside and inside;

silicone is available as an option upon request.

or by selecting solar control glass with reflective

Features and benefits

Car showrooms

or Low-Emissivity coatings (eg Viridian EVantage),

Shopping centres

ThermoTech can optimise energy management

Podiums

whilst maintaining natural light transmission.

Ground floor atriums

Airports

Museums

Art galleries

environment and is suitable for all climates.

Sporting grandstands

There are three spacer options within the

Other commercial applications

ThermoTech range.

Residential windows

Multi storey apartments

Special applications
.

Please consult with Viridian prior to


using ThermoTech in the following
applications:

By reducing the air-to-air heat transfer, ThermoTech


provides a more stable and controllable internal

Almost any shape, size and thickness including


offset or stepped units all four sides are
possible

. 

Uniform temperature over the entire surface

. 

Tolerates thermal stresses and pumping wind


loads

. 

Structural silicone seal (upon request) with


argon gas fill for unmatched insulation

. 

Metal Spacer
Two pieces of glass are separated by a metal
spacer and sealed to provide a hermetically
sealed air gap. It has a primary water vapour
proof seal and the secondary seal is supplied

Structural or silicone glazing

standard as polysulphide. Structural silicone

Swimming pools

secondary seal is an option upon request.

Roof glazing

The airspace is provided with a desiccant to

Sound reduction

prevent condensation forming within the unit.

Reduces outside noise factors by up to 50%


or more

. 

Argon gas standard

. 

Inbuilt desiccant in the TPS prevents


condensation forming in the unit

. 

Triple glazed options are also available in


TPS only

. 

Features and benefits


Increased insulation and reduced energy costs

. 

Wide range of solar control options that can

. 

be customised for each project


Suitable for hot and cold climates

. 

Can be incorporated with a Low E coating

Performance comparison chart

for additional insulation

ThermoTech

Reduced condensation

. 

. 

Note: Triple glazing option (shown


above) is available in TPS version only.

Insulation

Solar

Daylight

Clear

2.5

0.71

78

SuperGreen

2.5

0.39

59

Evantage SuperGreen

1.7

0.30

44

For comprehensive performance comparison data refer to page 130.

viridianglass.com

A superior balance of light


transmission, solar control
and thermal insulation
Viridian PerformaTech balances high levels of

. 

light transmission with very low levels of solar heat

. 

Energy

Broad range of product combinations


Available only as part of a Viridian ThermoTech
insulating glass unit (IGU)
for maximum performance

gain, low reflectivity and exceptional levels of


thermal insulation.

PerformaTech

Available in heat strengthened or


toughened form

. 

The performance characteristics help significantly


reduce both the heat and air conditioning levels
of a building, in turn actively contributing to the
provision of a perfectly balanced living and
working environment.

Selectivity
Glass selectivity is an index that reports the
relationship between light transmission and solar
heat gain, it is measured as an index (S = VLT/SHGC)

The high levels of performance associated

with a high selectivity more preferable in modern

with Viridian PerformaTech


, affords developers,

building design.

architects, designers and engineers alike the


opportunity to create economically viable,
aesthetically pleasing and environmentally
sustainable buildings. This in turn enables the
increasingly stringent demands of regulatory
requirements and prospective owners or tenants
to be easily met. Available only as part of a
Viridian ThermoTech insulating glass unit (IGU).
Viridian PerformaTech is available in either heat
strengthened or toughened form.
By combining Viridian PerformaTech with any one
of the Viridian range of products within an IGU, a
vast range of performance characteristics and
aesthetic options can be achieved.
Features and benefits
Exceptional balance of high light transmission,
low solar heat gain and low U Values

Solar heat entering a building can be limited


without reducing light levels by using a highperformance coated glass; this restricts UV and
Applications

infrared radiation from passing through but


importantly provides exceptional levels of natural

Fully supported by the Viridian product


warranty program

Offices

Curtain wall and large


glazedfacades

Commercial buildings
and curtain walls

High rise apartments

appearance as possible. Viridians glass possessing


the highest selectivity is our PerformaTech range.
High selective glasses, generally above 1.8 offer
exceptional performance which provides some of the
best energy savings through the lowest conductance
(U-Values) and best solar control (SHGC), high visible
light transmission assists in the requirement for less
artificial lighting during daylight hours.

Maximum size
.

Examples of Selectivity of Viridian glass;


Viridian ThermoTech SuperGrey Selectivity 0.38
Viridian ThermoTech Clear

Selectivity 1.09

Viridian PerformaTech Silver 236 Selectivity 2.36

Locally stocked and manufactured for short


lead times

. 

Nominally 3000 x 2000mm

How to specify
Select glass name
PerformaTech Clear 206
PerformaTech Silver 196
PerformaTech Silver 236

. 

Select thickness process


6+12+6 IGU

. 

Performance comparision chart

Select colour
Refer to performance
comparison chart

. 

Glass Make up

VLT

LR

SR

U-Value

SHGC

Selectivity

6mm PerformaTech Clear 206 +12mm Argon + 6mm Clear

68

13

38

1.36

0.33

2.06

6mm PerformaTech Silver 196 + 12mm Argon + 6mm Clear

59

16

32

1.36

0.30

1.96

6mm PerformaTech Silver 236 +12mm Argon + 6mm Clear

59

14

42

1.36

0.25

2.36

Glass Make up
6mm Grey + 12mm Argon + 6mm PerformaTech Clear 206

32

14

1.36

0.25

1.28

6mm Green + 12mm Argon + 6mm PerformaTech Clear 206

59

12

12

1.36

0.33

1.78

6mm SuperGreen + 12mm Argon + 6mm PerformaTech Clear 206

52

10

1.36

0.28

1.85

6mm SuperBlue + 12mm Argon + 6mm PerformaTech Clear 206

41

1.36

0.26

1.57

6mm SuperBlue + 12mm Argon + 6mm PerformaTech Clear 206

41

1.36

0.26

1.57

* W hen

For commercial buildings with


large expanses of glazing that
require the highest performance
inenvironmental control for energy
savings, yet retain transparency

daylight whilst also retaining as neutral and natural

. 

. 

the Viridian PerformaTech is the outside glass the coating is to surface 2, when it is the inside glass the coating is to surface 3.
IGU Gap = 12mm and is Argon filled.

viridianglass.com

Optimum performance solutions


with infinite glass combinations
Super Spacer

Considerations

Super Spacer comprises a Thermoset structural

foam containing no metal, an integrated 3A


desiccant and an advanced multi-layer vapor

frame design in accordance with AS/NZS4666.


Do not expose ThermoTech edges to standing
water and moisture as this can result in seal
failure. The frames must incorporate impervious
weather seals or a self draining system.

barrier structure. It is a warm edge solution that


minimises the transfer heat escape path for
optimal performance.
Features and benefits
. Advanced multi-layer vapor barrier structure
. Integral

3A Desiccant
.

.
.
.
.
.
.

Excellent Resistance to Nitrogen and Argon


Gas Absorption
Allows for expansion and contraction
Structural integrity
No compression set

Flexible Thermo set structural foam


Excellent UV Resistance
Temperature Resistance (from 51C to 127C)
100% Thermoset
structural foam
containing no
metal with integral
3A desiccant

 lazing compounds, sealants and gaskets


G
need to be approved by Viridian for suitability.

Frame
design the Viridian Warranty relies on

 ind load and safety determine the type


W
and thickness of glass required refer
Australian Standard AS1288 or New Zealand
Standard NZS4223.

Please
refer to the technical glazing
specification on the website for installation
instructions.
Visual characteristics and manufacturing
tolerances ThermoTech is manufactured to
AS/NZS4666. Also refer to the Viridian website
for specification and installation information,
including distortion and reflection from
changes in exterior and interior pressure
and temperature.

Handling and storage


Special handling is required. Refer to Viridian
literature. When transporting above altitudes
of 800m, special precautions apply. This must
be brought to the attention of Viridian.

Advanced multi-layer
vapor barrier structure

Optional PIB for


structural glazing
Sealant and
glass bonding

Insulation performance U Value


VFloat*

EnergyTech*

Single glass

5.80

3.70

Insulation performance U Value


EnergyTech*
for both panels

VFloat*

EnergyTech*

5.80

3.70

Single glass

EnergyTech*
for both panels

6mm argon

2.83

2.09

1.97

6mm air

3.10

2.51

2.43

12mm argon

2.52

1.61

1.48

12mm air

2.67

1.87

1.75

18mm argon

2.55

1.68

1.54

18mm air

2.69

1.94

1.83

*6mm glass argon filled.


TPS, Metal Spacer and Super Spacer are available in some
markets as standard option other markets by request.

*6mm glass air filled

Energy

Insulation performance
The width of the spacer and the
performance characteristics of the glass
selected such as EnergyTech determine
the U Value.
Viridian recommends increasing the
spacer then adding EnergyTech Low E
to economically enhance the insulation
performance of the insulating glass unit.
Changing the spacer type to TPS and
argon gas will also significantly enhance
the total window performance.

viridianglass.com

Overview of ThermoTech
spacer range
ThermoTech TPS

ThermoTech Metal Spacer

Energy

ThermoTech Super Spacer

Reduced condensation
ThermoTech reduces the incidence
of condensation. The onset of
condensation on the glass depends
on the relative indoor humidity, thermal
transmittance of the glazing (U Value)
and the relative indoor and outdoor
temperatures. The lower the U Value,
the less likely condensation will occur.

TPS is a butyl-based

ThermoTech comprises two

Super Spacer comprises

thermoplastic material.

panels of glass separated by

a Thermoset structural foam

It is UV stable with integrated

a metal spacer that is sealed

containing no metal and

desiccant and applied directly

with a primary vapour and

integrated 3A desiccant and

onto the glass by a computer-

a secondary seal to provide

an advanced multi-layer vapor

controlled nozzle. This non-

a hermetically sealed airspace.

barrier structure. It is a warm

metallic spacer offers the

The spacer has a desiccant to

edge solution that minimises

ultimate heat insulation with

prevent moisture forming inside

the transfer heat escape path

excellent tension, expansion

the ThermoTech unit.

for optimal performance.

Maximum size

Maximum size

and resilience properties.


Maximum size
.

4500 x 2700mm

Minimum size
.

350 x 190mm

TPS spacer

Spacer thickness any thickness


between 6mm to 18mm

Unit thickness 12mm to 58mm

Maximum unit thickness is 45mm


for double glazed units, 76mm
for triple glazed units

Maximum glass thickness


17.52mm

Triple glazing Yes

Shapes Yes

Argon gas fill standard

3500 x 2000mm

5100 x 2700mm

Minimum size

Minimum size

350 x 250mm

250 x 180mm

Metal Spacer

Super Spacer

Argon gas fill standard

Air space 6, 8, 10, 12, 16, 18


and 20mm

Maximum thickness 47mm

Shapes Subject to factory


confirmation

.
.

.
.

Argon gas fill standard


Secondary seal Polysulphide
and Silicone
Shapes Yes
Unit thickness 12mm to 52mm
double glaze only

Maximum weight
If any single IGU exceeds 300kgs
please contact Viridian for details

Weight
Product (mm)

Weight (kg/m2)

4 + 12 Air + 4

20

6 + 12 Air + 6

30

10 + 12 Air + 6

40

12 + 12 Air + 6

45

Noise
In an ever increasingly noisy world,
Viridian offers effective sound
reduction. While glass plays a vital
role, we also bring our experience
to all aspects of what is often a
multi-faceted problem/solution.

viridianglass.com

Noise
VLam Hush
ComfortHush

55
56, 57

A sound solution for effective


noise reduction

Noise

Reducing unwanted noise

A detailed solution would involve measuring the

Whether its from traffic, aircraft, trains, factories or

nature and intensity of the offending sound and

even neighbours, unwanted noise is a nuisance but

choosing a glass product which would reduce the

it can be reduced with the right selection of glass.

intensity sufficiently at all frequencies.

The Viridian VLam Hush range of laminated glass

It should be noted that glass is only one part of

is specifically developed to do just that.

the room and all other components must be


assessed as well. Example: For a living room on

Designing to solve a noise problem

a busy street, the required glass Rw value is 75dB

There are generally three components to be

(busy street) 40dB (living room) = 35dB (glass).

considered when solving a noise problem. These

Refer to Table 2 for glass options.

are the external noise, the noise reduction of


the wall (windows and glazing) and the resulting
noise in the room. The process of design requires

Rw is the weighted sound reduction in decibels

that the external noise level is determined by

which incorporates a correction for the ears

measurement and the desired internal noise level

response. A 10db increase is perceived as twice

is decided (refer Table 1). The design exercise

as loud whereas a 10db decrease is perceived

is then to construct the wall in order to reduce

as half as loud.

the external noise level to that desired in the

Common solutions

room where the external noise is known from

Thick glass the greater the thickness the


better the noise reduction for low frequencies
such as traffic noise. However, standard glass
has a coincidence dip when the glass vibrates
at the same frequency as the noise source.
This is dependent on glass thickness but
generally occurs at higher frequencies.

. 

measurements and the internal noise level is


recommended (ISO 140). For glass, this would
involve subtracting the Rw value of the external
noise level from the desired internal level to
determine the type of glass required.
The source of the noise may be higher at certain
frequencies. Typically, suburban traffic noise is a
low frequency noise, while aircraft produce a high
frequency noise.

Table1
Common sound levels
Environment

dB
0

Bedroom

3040

Conversational speech

65

Classroom

3540

Average traffic (kerbside)

70

Living room

4045

Busy traffic

75

Private office

4045

Loud traffic

80

Open office

45+50

Live band (20 metres)

105

. 

dB

Table 2 Sound insulation data (dB)


Monolithic

Laminated

VLam Hush

6.38 10.38 12.38 6.5

Thickness (mm)

10

12

15

19

Single

30

32

32

36

37

37

40

33

36

37

36

38

39

40

34

35

40

42

43

ThermoTech is an IGU with 16mm airspace and 6mm, 8mm or 10mm outer and 8.5mm VLam Hush inner.

viridianglass.com

8.5

Laminated glass the interlayer is particularly


effective at dampening which provides superior
sound reduction over the same thickness
monolithic glass. Further, the dampening effect
of laminated glass reduces the coincidence
dip at these higher frequencies and therefore
is a solution for aircraft and voice noise.

. 

Double glazing standard insulating glass


units do not provide good noise reduction.
For insulating glass units to be effective, an air
gap of 50mm to 100mm needs to be provided.
However, the incorporation of one or two
panels of laminated glass, a glass of differing
thickness or VLam Hush into the unit provides
excellent results.

Recommended interior noise levels

Threshold of hearing

ThermoTech

Sound reduction index

10.5 12.5

Noise
Description

Features and benefits

Viridian VLam Hush is a laminate that uses

. 

a specially developed interlayer to dampen

. 

noise, providing enhanced sound insulation


performance. This means that thinner and
lighter glass can be used for equivalent
acoustic performance. VLam Hush reduces
the coincidence dip of standard monolithic
and laminated glass.

Laminated Grade A safety glass

VLam Hush

Available in 6.5 to 12.5mm thicknesses


in 3660 x 2440mm
Can be incorporated with other solar control
glass options. Cannot be combined with
other tinted interlayers

. 

Can be incorporated in a ThermoTech


insulating glass unit

. 

Considerations
Vents in a wall provide a simple entry point for
noise. In most houses there is a gap between
the roof and the ceiling above the external walls
which allows noise into the ceiling space. If the
house is built on stumps then noise has access
to the under floor space. Windows and doors
which do not seal well will also allow noise to pass
around their frames, so a proper assessment of
the entire building is required in order to develop
an adequate solution.

Specific to New Zealand, VLam Hush is manufactured as


a CIP Laminate where two sheets of glass are bonded
together using a specifically formulated noise reduction
resin as the sound reducing interlayer. The CIP laminating
process provides a wide range of glass options and is
particularly suited for toughened laminated glass. It is
manufactured with a clear edge tape to separate the
glass before a UV cured resin is used to laminate the
glass and produce a Grade A safety glass.

Applications
Apartments

Offices

Hospitals

Airports

Buildings close to main roads

Maximum size
3660 x 2440mm

Thickness of resin (New Zealand)


1mm

1.5mm

1.8mm

How to specify
Select glass name
Viridian VLam Hush

. 

Select thickness process


6.5mm to 12.5mm Laminated

. 

Select colour
Refer to product range chart

. 

Product range
Thickness (mm)
Product
Clear

6.5

8.5

10.5

12.5

Other custom laminated options available

Enjoy your neighbourhood


with less noise

Noise
ComfortHush

Description

glass* found in many residential windows. In fact,

ComfortHush is an acoustic performance glass,

ordinary 3mm glass would need to be at least

which also features a durable Low E (low emissivity)

three times as thick to offer the equivalent sound

coating. It is available as a 6.5mm and 10.5mm

reduction as ComfortHush 6.5mm.

Grade A laminated safety glass that uses a special

Addressing a noise problem

3-layer acoustic PVB laminate that is specifically


designed to reduce sound transmission. The
inclusion of a durable Low E coating also provides
improved energy efficiency performance, by
helping to keep homes and buildings cooler in
summer and warmer in winter.

The best way to solve a noise problem is to address


it at its source. If this is not possible, then products
like ComfortHush help address the paths noise
takes when entering homes and buildings.
Typically the weakest point in a building is the
windows. Installing windows with good acoustic

3-layer
laminate
dampens
noise and
reduces
vibration
Low E coating
acts like
insulation
Up to a 6dB
reduction
in sound
transmitted
to the inside
compared to
ordinary glass*

performance needs to be supported with the


careful selection and insulation of walls, floors and
roof materials to enhance the overall acoustic
performance of the building. It is essential to
ensure that all other paths in the exterior of the
building have also been sealed. It is advised
that ComfortHush be used in conjunction with
those building products that have been carefully
engineered to reduce external noise intrusion
into buildings, control and dampen sound within

TViridian has engineered ComfortHush to reduce

buildings and improve the overall acoustic

unwanted noise entering homes and buildings,

performance of buildings.

whilst providing improved energy efficiency


performance. ComfortHush 6.5mm provides a
6dB improvement compared to ordinary 3mm

Normal
conversation

60dB

Dog
barking

70dB

2x as loud as 60dB

Loud
traffic

80dB

4x as loud as 60dB

Train whistle
at 150m

90dB

8x as loud as 70dB

Lawn mower,
truck, car horn

Loud rock
concert

100dB

115dB

16x times as loud as 70dB

The nature of the decibel scale illustrates how a small variation in decibels equates to a large variation in what we hear.

viridianglass.com

Noise
ComfortHush

Reduce the transmission of noise

Make a sound decision on frames

There are three things that occur when sound

To avoid noise leaks, you need to ensure that

waves encounter a window.

ComfortHush is installed in a frame thats well

1. They may be reflected away, causing little

sealed and professionally fitted. If the frame isnt

concern to those inside the building

Reflection

Vibration

sealed properly then ComfortHush cant work to


its full potential.

2. They may be absorbed through dampening


and dissipated, causing little concern to those

Talk to an experienced architect, builder or window

inside the building

fabricator to learn more about how ComfortHush

3. What isnt reflected or absorbed is transmitted

Transmission

Source

Receiver

can help keep your building more tranquil.

through the window by vibration or air leakage

Air Leakage

ComfortHush is the start of a comprehensive


range of single and double glazed acoustic

Reduce vibration

performance glass products made by Viridian.

Ordinary glass can vibrate at the same frequency

Refer to the Viridian VLam Hush range for more

as the noise source, allowing sound to penetrate

acoustic performance glass products.

through the window. ComfortHush includes a

Features and benefits

special 3-layer laminate that has been specifically


engineered to reduce vibration, making it effective

ComfortHush6.5mm can be installed into most

Applications

. 

in reducing urban noise.

single glazed window frames

New homes

. 

Residential renovations

. 

ComfortHush 6.5mm provides up to 39%


better insulation than ordinary glass resulting in
a more comfortable home and energy savings
all year round

. 

Reduce air leakage


Cracks, crevices and even the most minute gaps
will greatly reduce the performance of windows by
providing opportunities for sound to travel

ComfortHush is a Grade A safety glass and


helps to protect your interior furnishings from
fading by eliminating 99% of Ultra Violet
(UV) light

Unit developments and apartments

. 

Replacement and retrofit glazing


- Office Buildings
- Retail
- Institutional and social buildings

. 

. 

through. It is critical that ComfortHush is used


in combination with a carefully selected window
frame that is well sealed to significantly reduce

Maximum size
3660 x 2440mm

. 

How to specify

air leakage. Many window manufacturers make


and test windows designed to improve acoustic
performance and energy efficiency. It is important
these windows are professionally installed to

S elect glass name


Viridian ComfortHush

Select colour
Refer to product range chart

reduce air leakage by ensuring a good seal


between the exterior of the window and the wall it
is being installed into.

Product range
Thickness (mm)
6.5

10.5

ComfortHush Clear

ComfortHush Neutral

Product

Performance data
Product Name
ComfortHush Clear

Nominal
Thickness

Acoustic Rw

6.5

36

Visible

Solar

Trans.

Refl. Out

Refl. In

Trans.

Refl.

82

10

11

64

UV Trans

U Value

SHGC

Shading
Co.

Weight m2

<1

3.6

0.68

0.79

15.4

ComfortHush Neutral

6.5

36

59

42

<1

3.6

0.51

0.60

15.4

ComfortHush Clear

10.5

39

79

11

11

58

<1

3.6

0.64

0.74

25.5

ComfortHush Neutral

10.5

39

62

10

40

<1

3.6

0.49

0.58

25.5

All performance data is determined using LBL Windows 5.2 software, NFRC 100-2001 conditions have been used.
* Based on comparison of weighted sound reduction index (Rw) of ComfortHush and 3mm annealed float glass.
Based on comparison of weighted sound reduction index (Rw) of ComfortHush and 10mm annealed float glass.
Based on U-value comparison of 4mm clear float glass.

Clear Vision
Choose from the Clear Vision range
where excellent transparency and clarity
is required for superior views.

viridianglass.com

Clear Vision
SuperClear TC
61
OptiView63
Renew65

viridianglass.com

Sometimes the best solutions


are ones that are hardest to see
Description

Features and benefits

Viridian VFloat SuperClear TC provides

High clarity, crystal clear, low iron glass for

maximum transparency and clarity by providing

special applications.

a crystal clear glass unlike the green tint usually

. 

Clear Vision
VFloat
SuperClear TC

Purity and trueness of colour with minimum


colour cast when viewing through the glass

found in standard float glass. This is achieved

Translates light coloured paint more accurately


than standard float glass

by using silica sand with a low iron content

. 

during glass making to reduce the otherwise

Very high light transmission of 90% and over

characteristic green of standard float glass.

. 

When painted, VFloat SuperClear TC

. 

represents colours, in particular light colours,

. 

much more accurately than standard

. 

High solar transmission for solar power


Can be toughened and laminated
Maintains colour consistency over the
range ofglass thickness

float glass.

Used in Seraphic and very thick products


such as Viridian DcorFloor to minimise
natural green tone

. 

The result is readily apparent with thick glass


where the edges remain clear and colour
transmittance is more accurately processed.

Applications

Viridian VFloat SuperClear TC is available

Showerscreens

in laminated, toughened and toughened

. 

laminated form. It is particularly useful when

. 

glass has an applied design or colour such

. 

Splashbacks
Shopfronts and display cases
Balustrades and Total Vision
systementries

. 

as Viridian Seraphic where light colours


such as white remain true.

Furniture

. 

VFloat SuperClear TC can be used to stunning

. 

effect in balustrade systems, frameless shower

. 

screens and furniture where a processed glass

. 

edge is exposed and clarity of vision is desired.

. 

Shelving
Seraphic glass for true colours
Appliance glass
Solar collectors and high
performance mirrors

The sheer beauty of this product opens up a raft

Specialist applications requiring


thickglass, e.g. DcorFloor
customised laminate

. 

of new possibilities forarchitects and designers.


The table below shows the light and solar
transmission performance for Viridian VFloat

Maximum size

SuperClear TC and standard float glass.

. 

Stock range 5100 x 3210mm


Laminated 5100 x 3210mm

. 

How to specify
Select glass name
Viridian VFloat SuperClear TC

. 

Comparision of light and solar transmission


Light transmission %
Glass thickness

VFloat Clear

SHGC

VFloat
SuperClear TC

VFloat Clear

4mm

89

91

0.85

0.91

6mm

88

91

0.82

0.90

8mm

86

91

0.77

0.89

10mm

85

90

0.75

0.89

12mm

84

90

0.72

0.88

15mm*

82

90

0.70

0.87

* VFloat SuperClear TC 15mm subject to availability.

Select thickness process


4mm to 15mm Annealed
4mm to 15mm Toughened
4mm to 12mm Heat Strengthened
8.38mm to 31.52mm Laminated
9.52mm to 31.52mm
Toughened/Laminate

. 

VFloat
SuperClear TC

viridianglass.com

Anti-reflective glass

Clear Vision

Description

Considerations

Viridian OptiView reduces glass reflection to

. 

OptiView

The coatings are glazed to the inside and


outside of the building on surfaces #1 and #4
and have a different surface and appearance
to normal glass. The coatings are very durable
and have specific cleaning and handling
instructions. Please refer to viridianglass.com

less than 2% compared with 7% for standard


float glass when viewed from both the inside
and outside. This unique glass is designed for
applications where transparency is required in
combination with an extremely low reflective

The designer must determine the suitability


of OptiView in situations where the presence
of glass may not be sufficiently obvious and
take any necessary precautions.

. 

appearance. These characteristics provide


OptiView with very high clarity for viewing through
the glass. It significantly removes the apparent
barrier between the object and the observer.

Features and benefits

OptiView is a laminated glass and combines a

. 

transparent anti-reflective coating on clear glass,


using pyrolitic coating technology to form a hard

Transparent, unimpeded views and high clarity


of showcased objects due to significantly
reduced reflectivity.
A subtle and almost unnoticeable barrier
between the object and the observer.

Applications

Extremely low external and internal light


reflection of less than 2%.

Where maximum clarity from one or both


sides is required:

. 

and durable coating. The coatings, one exterior


(surface #1) and one interior (surface #4), work
in unison and both are required to achieve the

. 

significant reduction in reflectivity.


In addition to its anti-reflective properties, OptiView
offers better thermal insulation, reducing heat loss
by up to 25% compared to standard glass. It also
blocks more than 99% UV transmittance and yet

Very high daylight transmission of more than 90%.


Improved thermal insulation over standard glass.

. 

Over 99% UV elimination to reduce fading.

. 

Human impact safety OptiView is a laminated


Grade A safety glass to AS2208. It reduces the
potential for injury and if broken, remains in place.

clear glass. Offering the traditional benefits of


laminated glass, it provides enhanced security,
acoustic control when provided with Viridian
VLam Hush specialist noise reducing interlayers.

OptiView can be used in both interior and exterior


applications. These include museum and display
cases, retail shopfronts, showrooms and many

Security thicker interlayers are available for


additional strength and increased resistance
to physical attack.

. 

Range of sizes and thicknesses available.

may not previously have been an option, such

. 

Warranty, refer to page 122.

as facilitating night views from apartments, hotels


or restaurants.

Performance data
Visible
refl.%
(internal)

Solar
trans.
%

Visible
refl.
%

UV
trans.
%

U Value
trans.
(W/m2C)

Shading
coeff.

SHGC

88

78

60

5.8

0.95

0.82

OptiView

6.38

92

1.7

1.7

70

<1

4.6

0.89

0.77

OptiView

12.38

90

1.6

1.6

63

<1

4.4

0.83

0.72

Standard glass is Viridian Vfloat Clear. Typical measured values of Viridian production are provided.
All performance data is calculated using LBL windows 5.2 software, NFRC 100-2001 conditions have been used.
Minimum size is not the maximum glazing size. Refer to AS1288. Performance data is centre of glass values.
**

OptiView is a registered trademark of Pilkington Group Limited.

Apartments

Hotels

other applications where anti-reflective glass

Standard glass**

Corporate boxes

Noise reduction combine with Viridian VLam


Hush to achieve significant noise reduction.

. 

Visible
refl.%
(ext)

Restaurants

Maximum size

. 

Applications

Visible
trans.
%

Retail shopfronts

The durable pyrolitic coating means that


OptiView can be cut and processed, or
fabricated into insulating glass units. The glass
can be toughened or curved prior to laminating.

. 

safety and damage protection, and superior

Nominal
thick.
mm

Museum and retail display cases

. 

still allows more visible light to pass through than

Product

Showrooms

. 


3302 x 2438mm

Thicknesses
6.38mm and 12.38mm

How to specify
Select glass name
Viridian OptiView

. 

Select thickness
6.38mm 12.38mm

. 

viridianglass.com

The worlds first self cleaning glass

Clear Vision

Viridian Renew represents the latest

If rain does not normally reach the glass, dirt

development in glass technology. The special

deposits are less likely to be washed away and

Renew

dual action Renew coating helps keep glass free

may need more regular hosing. Renew is not

from organic dirt, saving time, money, water and

suitable for interior use.

detergents all associated with window cleaning


for the life of the window. Cleaning costs,
especially those associated with large buildings
over the life of the building are significant. Renew
provides a quick payback on investment.
Description
Renew has a specially developed, completely
transparent exterior coating. This is applied
during manufacture to clear glass, producing an
innovative dual cleaning action. Once exposed
to daylight it reacts with the UV rays to breakdown
and disintegrate organic dirt deposits such as bird
droppings and tree sap. Secondly, when water
hits the glass, Renew has a hydrophilic quality
that assists in washing dirt away without leaving
spots or streaks.
During dry spells and cloudy days Renew will
continue to break down organic dirt but the
lack of sufficient rainfall may prevent the
hydrophilic washing.
Renew works continuously with dirt being washed
away whenever it rains. The coating can take
between five to seven days after glazing
toactivate.
Renew can be combined with other glasses
such as a solar control laminate (Viridian VLam)
or insulating glass unit (Viridian ThermoTech) for
thermal comfort.
Applications
Renew can be used in almost any exterior
application. It can be installed at any angle
ranging from vertical or sloped roofs of no less
than 10. Ideally 30 is recommended. It is
especially useful for inaccessible windows or
windows that are unsafe to clean and where
dirt collects, such as roof lights.

Considerations
Only approved sealants can be used in
structural silicon or weather seals. Careful
attention to window design and selection
is required.

. 

Gaskets for the window system must be


neoprene or butyl based tapes.

. 

For areas that have hard water and/or sea


salt spray, special attention to selection is
required. Please consult with Viridian for
recommendations.

. 

Renew is a self-cleaning product designed


for organic material deposits on glass. It is
not effective at breaking down salt deposits
or other inorganic materials. It is therefore not
recommended for use in coastal or high salinity
areas where salt film build up is an issue.

. 

Applications
Residential and commercial windows

. 

Roof lights that are inaccessible

. 

Maximum size
3660 x 2440mm

. 

Features
Transparent with virtually identical properties
to clear glass of the same thickness.

5100 x 3210mm

. 

. 

Durable the Renew glass coating uses


Viridian pyrolitic coating technology. It can
be laminated, toughened, curved and
incorporated into ThermoTech and is stored
and handled in the same way as normal glass.

. 

Renew can be incorporated with virtually


all Viridian solar control, ThermoTech and
decoration glass.

. 

Laminated for safety and noise reduction.

. 

Warranty, refer to page 122.

. 

Benefits
Saves cleaning time and costs

. 

Glass options
VLam
Available in 6.38mm, 8.38mm,
10.38mm, 12.38mm

. 

Customised laminate or IGU


also available

. 

How to specify
Select glass name
Viridian Renew

. 

Select thickness process


6.38mm to 13.52mm Laminated
9.52mm to 13.52mm
Toughened/Laminate

. 

Select glass combination


Contact Viridian for assistance

. 

No need to access high or unsafe areas

. 

Reduced water and detergent use

. 

Range of laminated and insulating glass


options, providing energy management

. 

Product range
Thickness (mm)

Added safety and security with reduced noise

. 

Float
Clear
Laminated
Clear

6.38

8.38

10.38

12.38

Decorative
Viridian creates a world of colours,
patterns, textures and effects.
From traditional to modern designs,
from purely decorative to structural
applications, these products
demonstrate twenty-first century
glass production technology
at its most advanced.

viridianglass.com

Decorative
DcorPattern68
Seraphic Standard
71
Seraphic Design
73
DcorSatin74
DcorSatin Grey
74
DcorSatin Mirror
74, 77
VLam Translucent
75
VLam Translucent Grey
75
VLam Soft White
75
DcorMirror77
DcorMirror Laminate
77
DcorMirror Safe
77
DcorPanel79
DcorFloor80
DcorColour81
Digiglass83

Decorative

Light, privacy and decoration

DcorPattern

Viridian DcorPattern comprises a range of

Privacy with translucency

DcorPattern styles and visual effects providing

Privacy is an important design consideration.

opportunities for modern design or the faithful

DcorPattern is appropriate for areas requiring

re-creation of dcor from a by-gone era. It is

obscuration and privacy and for areas where

suitable for windows and interiors.

privacy from overlooking is required without

Description

sacrificing natural light. DcorPattern provides


degrees of privacy through light diffusion and

DcorPattern is manufactured by passing a

obscuration. The level of obscuration is

continuous molten glass ribbon between two

indicated by:

rollers, one of which has a pattern that creates

Most

a permanent impression. DcorPattern has all


the attributes of glass; durability, ease of cleaning
and resistance to scratching and marking. It is

Medium

Least

The most obscuration is suggested for


overlooking privacy.

stocked by most distributors and is a low cost

Features and benefits

decorative option.

. 

Contemporary range stocked for ease


of availability.

Wires are incorporated into some DcorPatterns.


Polished Wire is further processed by polishing the
surfaces to form an optically clearer product and
is often used as fire resisting glass. Polished Wire

Economical method of providing permanent


privacy and decoration.

. 

White and toned options.

. 

Can be toughened or laminated for Grade A safety.

. 

is also suitable for decoration.


The DcorPattern range includes white or
clear patterned glass, bronze, grey and clear
wired glass.
Some of the range can be toughened or
laminated to provide a Grade A safety glass.

Product range
Type

Product

Textured
Glue Chip

Clear

Wired

4mm

5mm

6mm

Grey

5mm

5mm

Spotswood

Dark Grey

Safety Form
Tough

Wired

.
.

Direct

Obscure

Squarelite

Polished Wire N

Toughening and laminating the above chart illustrates the


suitability of the various patterns to be laminated (using the PVB
method) or toughened.
Fire resistance while Viridian wired glass does not on its own
have a fire rating, it can be part of a glass/door/window assembly
which as a complete unit may achieve a fire rating.

Glazing
Non
Direct

Satinlite
Cathlite

viridianglass.com

Bronze

Thermal resistance wired and toned texture glass absorbs solar


radiation and may be subject to thermal stress. It is preferable not
to expose wired glass to severe direct sunlight. Similarly, jets of very
hot water sprayed directly onto wired glass may result in thermal
cracking and should be avoided. Further technical advice should
be obtained from Viridian before specifying.

DcorPattern range

Decorative
DcorPattern

Glue Chip

Satinlite

Spotswood

Applications
Windows for privacy and decoration

Shower and bath enclosures

Interior partitions

Door inserts

Wall panels and wall features

Lead lighting

Balustrades

Louvres

Furniture

Maximum Sizes
Cathlite

Cathlite Bronze

Squarelite

White DcorPattern
4mm @ 2440 x 1840mm

5mm @ 2440 x 1840mm

6mm @ 2440 x 1840mm

Tinted DcorPattern
5mm @ 2440 x 1830mm

Wired Squarelite
6mm @ 2440 x 1840mm

Polished Wire N
6mm @ 3300 x 1980mm

How to specify
Polished Wire N

Select glass name


Viridian DcorPattern

. 

Select thickness process


3mm to 6mm Annealed
4mm to 6mm Toughened
4mm to 6mm Heat Strengthened
6.76mm to 13.52mm Laminated
7.52mm to 13.52mm
Toughened/Laminate

. 

Image of 5mm Dark Grey is not shown, please consult


your local Viridian representative to obtain a sample.

Select colour
Refer to product range chart

. 

viridianglass.com

Unique designs with


an infinite palette
The range of Viridian screen printed glass
comprises of:
Viridian Seraphic Standard a range of
16standard opaque and translucent colours
(refer to colour chart below).

. 

Viridian Seraphic Design a range of 12


screen printed designs in standard colours.

. 

Viridian Seraphic Custom special designs,


patterns and colours.*

. 

Description

Decorative

Spandrel options
Seraphic Standard in opaque colours is
an excellent spandrel panel due to its low
maintenance and heat resistance. Care should
be taken to avoid back-lighting. Panels can
either contrast or complement the vision glazing.
A method to match the vision glass is to use
a Viridian ThermoTech unit with the vision glass
and the inner glass being a Seraphic colour so

decorative glass panels. They are manufactured by


screen printing a ceramic coating on to the glass
prior to the toughening process. The toughening
process fuses the ceramic paint to the glass surface
to provide a permanent and durable finish.
Considerations

Curtain wall spandrel panels


Wall cladding

Features and benefits

Internal partitions

Short lead times. The Seraphic Standard


colours and designs are held in stock, for short
manufacturing times.

. 

Seraphic Standard provides a wide range


of colours to match or contrast with glass in
curtain wall systems.

. 

Seraphic Design provides a range of different


designs with various light transmission and
solar control factors. It is ideal for laminated
overhead glazing.

. 

Virtually any colour can be matched by the Seraphic


process and custom designs are also available.*
Lead times will vary on custom designs and colours.
The natural green tone of standard glass can affect
light colours and can be minimised by specifying
Viridian SuperClear TC low iron glass. Translucent
colours will also vary depending on light source
and surrounding finishes. Seraphic can be used for
exterior and interior applications. The painted side
must be glazed to the interior of the building.
Seraphic Standard must be selected, manufactured
and glazed in accordance with relevant standards
(refer to page 122) and Viridian processing

Applications
.

providing opacity and insulation.

Seraphic Standard is a range of toughened

Seraphic Standard

Seraphic Custom provides design freedom


with infinite colour and design options.

. 

Glazing uses standard fittings, framing


and sealants.

. 

The ceramic coating is durable, lightfast and


will not crack even in demanding applications
up to temperatures of 250C.

. 

Seraphic glasses are non-porous and


easilymaintained.

. 

Seraphic is a Grade A safety glass


(AS/NZS2208) when toughened.

Splashbacks and sign boards

Automotive and marine

Minimum size
300 x 150mm

. 

Maximum size
4500 x 2200mm

Thickness
4mm to 19mm

Interior
Internal partitions

. 

Showerscreens

. 

Splashbacks

. 

Furniture

. 

Signage

. 

Privacy

. 

Exterior
Balustrades

. 

Spandrels

. 

Overhead canopies

. 

Privacy

. 

. 

Roof lights

. 

Sunshades

. 

guidelines for toughened glass. Recommendations

Other

on heat soak treatment apply (refer to page 120).

Automotive

. 

Marine

. 

Colours to match Colorbond Steel

How to specify
Select glass name
Viridian Seraphic Standard

. 

Select thickness process


4mm to 19mm Toughened
4mm to 12mm Heat Strengthened
9.52mm to 39.52mm Laminated
9.52mm to 39.52mm
Toughened/Laminate

. 

APO Grey

Jasper

Stone

Paperbark

Night Sky

Woodland Grey Cottage Green Deep Ocean

Dulux Powder Coat colours

All Seraphic Custom colours are to be


matched to either Dulux Master Palette
or Dulux Powder Coatcolour ranges
only. Surcharges may apply.
Lemon Yellow

Orange

Signal Red

Pommel Blue

Mistletoe

Brilliant White

White Frost

This colour swatch is to be used as a guide only. The final glass colour may differ from these printed swatches.
Colorbond is a registered trademark of Bluescope Steel. Dulux Powder Coat and Dulux Master Palette are
registered trademarks of Dulux.
*Subject to volume requirements.

Frost

viridianglass.com

Fresh designs, ready to go

Decorative

Viridian Seraphic Design provides designers

Notes on custom colours and designs

and specifiers with a range of readily available

. 

Seraphic Design

screen printed glass patterns that offer privacy,


light transmission and design options. The glass
is ideal for internal partitions, sunshades,
balustrades, roof lights and can be specified
in toughened or toughened laminated safety
glass options.

When specifying colour, reference should be


made to Dulux Master Palette or Dulux Powder
Coat colour ranges only (refer to colour chart
insert). The glass has a natural green tone
and this has an effect on the final colour.
It is recommended that a colour sample
be viewed in its final location.
Viridian SuperClear TC low iron glass is
available for colour correcting light colours.

. 

Range

Custom designs require new screens for printing


and lead times will vary.

. 

A range of 12 designs are available in the


ViridianSeraphic Standard colour range.
In addition, virtually any colour can be matched

Anti-slip finishes are available on request for


stairs and floors.

. 

and custom designs are also available.*


Translucent colours will vary depending on
lightsource and surrounding colours.

Solar and light transmission of Seraphic Design

Laminated glass

Pattern

Seraphic Design is ideal for incorporation into

Applications

% Cover

Visible Light
Transfer %

SHGC

. 

6mm Circle

27%

69

0.70

. 

a laminated glass with a Viridian solar control

3mm Dot

50%

48

0.56

. 

glass. This provides enhanced solar and glare

3mm Reverse Dot

42%

59

0.63

. 

control, privacy and a design motif. It is typically

5mm Dot

39%

61

0.64

Diamond

21%

74

0.72

Checkerboard

94%

23

0.41

50%

54

0.60

used in roof light glazing where Seraphic Design


provides the opportunity for diffused lighting.
Seraphic as a laminated glass may be required
by building codes in certain applications.

2mm Line/
2mm Gap
5mm Line/
5mm Gap
10mm Line/
10mm Gap
Spiders Wisp

50%

54

0.60

50%

54

0.60

NA

NA

NA

Grid #1
75%

(3mm Clear Block)


Grid #2
70%
40
0.51
(6mm x 15mm)
(Performance is an estimate only. Performance is based on
Seraphic Design on 6mm Clear).

Roof lights
Internal partitions
Sunshades
Automotive and marine
Privacy

. 

Maximum size
4500 x 2200mm

. 

Maximum size will vary by design.


Contact Viridian for details.

. 

Thickness
4mm to 19mm

. 

How to specify
Select glass name
Viridian Seraphic Design

. 

Select thickness process


4mm to 19mm Toughened
4mm to 12mm Heat Strengthened
9.52mm to 39.52mm Laminated
9.52mm to 39.52mm
Toughened/Laminate

. 

Seraphic Design range

Select design
Refer to design chart

. 

6mm Circle

3mm Dots

3mm Reverse Dots

5mm Dots

Diamond

Checkerboard

2mm Line/2mm
Gap (vertical
& horizontal)

5mm Line/5mm
Gap (vertical
& horizontal)

10mm Line/10mm
Gap (vertical
& horizontal)

Spiders Wisp

Grid #1
3mm Clear Block

Grid #2
6mm x 15mm

*Subject to volume requirements.

Decorative
DcorSatin
DcorSatin Grey
DcorSatin Mirror

Excellent privacy with high


light transmission
Viridian DcorSatin is a high quality translucent

Description

float glass that offers high light transmission,

DcorSatin is a float glass, where one side has

excellent privacy and ease of handling.

been treated with an acid etch to produce a

With its non-reflective matt satin surface, it lets in

satin finish. This process is applied to the entire

up to 87.5% of light, but diffuses it to give a natural

sheet of glass at the time of manufacture, to

feel. DcorSatin can be used in any number

ensure an overall consistent finish. The finish is

of applications including shelving, partitioning,

both moisture and UV resistant, making it ideal

doors, showerscreens, furniture, balustrades,

forexterior as well as interior applications.

privacy windows and louvres. Viridian now offers


DcorSatin Grey.
Viridian DcorSatin Mirror combines the best
features of DcorMirror and DcorSatin,
making it a high quality decorative product
perfect for interior applications. The silver coating
creates a unique and appealing metallic finish
Applications DcorSatin
Windows for privacy and decoration

. 

Shower and bath enclosures

. 

Interior partitions

. 

Door inserts

. 

Wall panels and wall features

. 

Lead lighting

. 

Balustrades

. 

Louvres

. 

Furniture

. 

Splashbacks, with a Seraphic


ceramic coating

. 

Applications DcorSatin Mirror


Wall panels and wall features

. 

Furniture

. 

Wardrobes (with vinyl back)

. 

Maximum Size
3210 x 2250mm

. 

Thickness
4mm,* 6mm, 10mm and 12mm

. 

How to specify
Select glass name
Viridian DcorSatin, DcorSatin Grey
or DcorSatin Mirror

. 

Select thickness process


(DcorSatin)
4mm to 12mm Annealed
4mm to 12mm Toughened
4mm to 12mm Heat Strengthened
8.38mm to 25.52mm Laminated
9.52mm to 25.52mm
Toughened/Laminate

. 

*DcorSatin Mirror only available in 4mm


annealed and vinyl back.

viridianglass.com

with a diffused light reflection, without being


spectrally reflective.

DcorSatin Mirror has been silvered after the


acid etch process to the non acid etched side.
Features and benefits
Easy to process, DcorSatin can be
toughened, laminated, or combined as
part ofa ThermoTech insulated glass unit

. 

Less susceptible to staining, with no special


cleaning instructions required

. 

Suitable for both interior and exterior


applications

. 

High light transmission

. 

Providing privacy with Grade A


laminated safety glass
Viridian VLam Translucent, VLam Translucent

Description

Grey and VLam Soft White are becoming

As with Viridian DcorPattern glass, where

popular for screening and privacy applications.

privacy is an important consideration, this

With a frosted appearance made by bonding

productis appropriate for obscuring vision

two or more sheets of glass together with a PVB

and diffusing light.

interlayer, the result is a durable glazing material


that can be used for a variety of applications.
As the translucent interlayer is contained between

VLam Translucent has a white appearance

Decorative
VLam Translucent
VLam Translucent
Grey
VLam Soft White

and alight transmission of 68%.

the two sheets of glass, the product does not

VLam Translucent Grey has a frosted grey

fingermark and is easy to clean.

appearance and a light transmission of 32%.


VLam Soft White has a light frosted appearance
and a light transmission of 80%.
Features and benefits
Contemporary range stocked for ease
ofavailability

. 

Economical method of providing permanent


privacy and decoration

. 

Applications
Internal partitions

. 

Balustrades

. 

Roof lights

. 

Privacy windows

. 

Showerscreens

. 

Maximum Size
6.38mm and 8.38mm VLam
Translucent @ 4280 x 2760mm

. 

10.38mm and 12.38mm VLam


Translucent @ 4600 x 2760mm

. 

6.76mm VLam Translucent Grey


@ 4280 x 2760mm

. 

6.38mm and 8.38mm VLam


Soft White @ 3660 x 2440mm

. 

10.38mm and 12.38mm VLam Soft


White @ 3660 x 2440mm

. 

Thickness
6.38mm, 8.38mm, 10.38mm
and 12.38mm

. 

How to specify
Select glass name
Viridian VLam Transluscent or
VLam Soft White

. 

Select thickness process


6.38mm to 12.76mm Laminated
7.52mm to 13.52mm
Toughened/Laminate

. 

viridianglass.com

Reflecting light and beauty


Description

Viridian DcorSatin Mirror combines the best

The Viridian DcorMirror range of products

features of DcorMirror and DcorSatin,

offers designers the ability to create emotive

making it a high quality decorative product

spaces using light and reflection with clear,

perfect for interior applications. The silver coating

tinted, safety and satin mirrors.

creates a unique and appealing metallic finish


with a diffused light reflection, without being

As the culmination of extensive design and


testing, DcorMirror is a world class product

Decorative
DcorMirror
DcorMirror Laminate
DcorMirror Safe
DcorSatin Mirror

spectrally reflective.

that provides excellent light reflection. As a high

Installation

specification mirror it incorporates outstanding

There are many techniques that can be used

protection of the reflective silver coating,

to install mirrors, from framing to adhering directly

without the need for the copper layer used in

to a door or wall. The adhesive to be used must be

conventional mirror processes. This provides

checked with the manufacturer for compatibility

greater resistance to natural corrosion, helping

with DcorMirror paint or vinyl backing. It is also

to minimise the unsightly problems of black

recommended that the adhesive only be applied

Applications

edges and spot faults. DcorMirror has two coats

in vertical strips. The product is not intended for

of special backing paint which gives additional

installation in the external environment.

Bathrooms
Wardrobes
. Traditional framed mirrors
. DcorMirror Safe is ideal for gyms
and internal wall cladding
. DcorMirror Laminate is suitable for
lifts, wall linings, dance studios, night
clubs, bars and high activity areas
where assessed and glazed in
accordance with relevant standards
Range

protection from steam, moisture and chemicals.

Cleaning

Also available are Viridian DcorMirror Safe

Some cleaning solutions can damage

and Viridian DcorMirror Laminate that

the mirror coating. Mild detergents are

comply with AS/NZS2208 for Grade A safety

recommended. For more information on

glazing materials. DcorMirror Safe is available

cleaning the Viridian DcorMirror range

in two different vinyl types, DcorMirror Safe

please visit www.viridianglass.com/Products

and DcorMirror Safe WB.* DcorMirror Safe


is backed with a smooth vinyl film, whereas

Features and benefits


Comprehensive range of decorative options

DcorMirror Safe WB features a woven vinyl

. 

backing. DcorMirror Laminate combines

. 

DcorMirror with the performance of VLam,


without the need for vinyl backing. These products
should be glazed in accordance with Australian
Standard AS1288, New Zealand Standard NZS4223
and other relevant standards.

Higher corrosion resistance than conventional


copper backed mirrors
DcorMirror can be edge worked with
bevelling and brilliant cut designs

. 

. 
. 

DcorMirror is manufactured in
a wide variety of sizes to minimise
cutting loss. DcorMirror Safe WB
is available on request, which includes
a woven vinyl backing. Non-standard
thicknesses such as 10mm and
DcorPatterned glass options are
available for specific projects
How to specify
. 

Select glass name


Viridian DcorMirror, DcorMirror Safe,
DcorMirror Safe WB, DcorMirror
Laminate or DcorSatin Mirror
. Select thickness process
3 to 6mm Silver; 6.38mm Clear
. Select colour
Refer to product range chart below
. 

DcorMirror Safe and DcorMirror Laminate


are available as a Grade A safety product

. 

Maximum size

Product range

DcorMirror

DcorSatin
Mirror

DcorMirror
Safe

DcorMirror
Laminate

3mm Clear

3660 x 2440

NA

NA

NA

Product

4mm Clear

3660 x 2440

3210 x 2550

2760 x 1220

NA

Clear

4mm Grey
and Bronze

3660 x 2440

NA

2440 x 1220

NA

6mm Clear

3660 x 2440

NA

2440 x 1220

6mm Bronze

3210 x 2550

NA

6mm Grey

3660 x 2440
NA

6.38mm Clear

*DecorMirror Safe WB is available upon request.

Thickness (mm)

Grey

Bronze

NA

Safe

2440 x 1220

NA

Black*

NA

2440 x 1220

NA

D/Satin Mirror

NA

NA

3660 x 2440

*By enquiry.

.
.

viridianglass.com

Subtle luminous qualities for a


contemporary decorative choice
Description

Features and benefits

Viridian DcorPanel is the ideal fashion and

. 

economic choice for wardrobe doors and

. 

decorative internal wall panelling, creating

Long lasting fashionable good looks.

Choice of two contemporary colours.

. 

quality in a room. DcorPanel is a paint coated

. 

glass, with a vinyl backing applied to the

. 

painted surface to provide Grade A safety glass

. 

protection. By placing the coating on the back of

. 

present in other opaque materials.

DecorPanel White available with SuperClear


Grade A safety glass for your protection.
Easy to clean surface.
Backed by a two year warranty
(refer to page 122).

Available in a range of standard stock sizes,

Colour options

DcorPanel is available in large seamless sheets

Available in three options.

ready for immediate installation.

DcorPanel White* creates a feeling of

Colours

sophisticated simplicity in a room, adding

DcorPanel

Cost effective interior decorative product


withthe unique beauty of glass.

a subtle luminous and striking contemporary

the glass it adds a sense of depth, not normally

Decorative

DcorPanel White

Applications

*The glass has a natural green tone, which

. 

DcorPanel Black creates an outstanding

will affect the product colour of DcorPanel

. 

visual impact with a true black finish.

White. We recommend viewing a product

. 

DcorPanel SuperClear for a premium white

sample to assist in selection.

. 

and bright finish.

DcorPanel Black and SuperClear

Maximum size

DcorPanel is purpose designed for wardrobe

We recommend viewing a product sample

. 

doors and internal wall panelling, using a super

to assist in selection.

. 

hard grade paint specifically for decorative

Designed as a dry area internal wall panelling

. 

glassapplications. With the painted surface

product, DcorPanel should not be used in

Thickness

baked onto the back of the glass and protected

circumstances where moisture is present,

. 

with vinyl, the coating will remain scratch resistant,

including, but not restricted to, kitchen

you can be assured it will maintain its lasting

splashbacks or bathrooms. For splashbacks

fashionable good looks. It is made to conform to

we recommend Viridian Seraphic.

a sense of space and light.

AS/NZS2208 Safety Glazing Materials in Buildings,


giving you greater peace of mind. DcorPanel is
backed by a two year warranty (refer to website
for more information).
Kids and even adults will love using the surface as
a fun palette with non-permanent marker pens to
create a masterpiece or just as a reminder board.
And being glass, it is easy to wipe clean. For full
cleaning instructions please visit our website.

Wardrobe doors
Retail shop fit outs
Decorative internal wall panelling
Dressing rooms

White @ 2760 x 1220mm


Black @ 2760 x 1220mm
SuperClear @ 2760 x 1220mm

4mm

How to specify
Select glass name
Viridian DcorPanel

. 

Select thickness
4mm

. 

Select colour
Select either White,*
Black or SuperClear

. 

Decorative
DcorFloor

Create the sensation


of walkingon air
Viridian DcorFloor is an innovative, low

Description

maintenance and safe alternative to traditional

DcorFloor is a composite of three or more

flooring systems and is ideal for feature staircases,

layers of annealed or Viridian VTough, with

internal and external walkways, display areas and

a PVB interlayer bonding these components

retail fit outs.

together. The top layer is a heat strengthened

It is often used to bring natural light down through

or toughened safety glass with a non slip coating

several floors of a building, brightening interiors.

fused onto the glass surface. The lower layers are

Other applications include staircases, entries

either annealed or VTough and act as a carrier

and foyers.

to the live and dead loads.

DcorFloor is a high-end laminated product

Features and benefits

that not only encompasses the physical design


elements that allow use in heavy trafficable

Applications

. 

graphic designs for both practical and aesthetic

. 

considerations.

Note that DecorFloor comes by default with full


seraphic non-slipcoating unless a patterned
alterative is specified.

DcorFloor requires technical expertise and

Internal and external walkways

our in-house engineer is qualified to advise

Entries

prospective clientele in glass thickness and

Foyers

framing requirements for the products correct use.

. 
. 
. 

Maximum size
2000 x 2500mm

. 

Thickness

Standard tested non slip patterns and their slip


resistant ratings
% Cover

R Rating*

10mm Dot

21%

R10

3mm Line @ 13.5mm spacing

22%

R10

3mm Line @ 9mm spacing

33%

R11

Select glass name


Viridian DcorFloor

6mm Open Circle

27%

R11

5mm Dot

39%

R11

Select thickness process


29.04mm to 47.04mm Laminated
(including 6mm non slip surface)
29.04mm to 47.04mm Toughened
Laminated (including 6mm non
slip surface)

Full Cover

100%

R13

29mm, 33mm, 39mm, 47mm


and 59mm

. 

How to specify
. 

. 

Options
Viridian VFloat or Viridian
SuperClear TC non slip pattern

. 

Other non slip options available


Colours can be incorporated
by introducing coloured PVB
interlayersplease contact Viridian
for these options.
DcorFloor limitations
Unless specified otherwise, DcorFloor
is designed for foot traffic only. High
concentrated loads from trolleys,
sharp objects or heavy furniture should
be avoided. For further information
please contact Viridian.

viridianglass.com

Range of Seraphic non slip patterns available

areas, but also combines the use of non-slip

Staircases

. 

Custom made to meet your individual


requirements

. 

Pattern

*R Ratings derived from AS/NZS4586:2004 slip resistant


classification of new surface materials.

SuperClear TC is also available

Please refer to Viridian Technical Services


for further information.

Explore the limitless possibilities


ofcoloured glass
This laminated product consists of a range

Features and benefits

of base coloured interlayers that can be

. 

Decorative

Wide range of colour options available


by combining base interlayers*

combinedto result in thousands of coloured

DcorColour

DcorColour can be combined with


Viridian Seraphic Design for a patterned
coloured option

laminate options.

. 

Description
The Viridian DcorColour range consists of 11

. 

transparent colours shades of blue, pink, yellow

. 

Custom made to size only


Wide range of applications

and grey. The foundation colours are Sapphire,


Aquamarine, Ruby Red, Coral Rose, Sahara Sun,
Golden Light, Evening Shadow, Smoke Grey, Deep
Red, True Blue and Tangerine. The translucent
colours available are Cool White and Arctic Snow.
There arealso opaque options in Pure White and
Black (refer to colour chart insert). The interlayers
are manufactured using heat and light-stable
pigments, not dyes, which enables you to use
colour that is lightfast. As the colour is laminated
between two sheets of glass, the product is easy
to clean and maintain. Being laminated, it is also
Grade A safety glass.

Colour codes are represented by the following


0001
Coral Rose
0002
Aquamarine
0003
Smoke Grey
0004
Sahara Sun
0005
Ruby Red
0006
Sapphire
0007
Evening Shadow
0008
Golden Light
0009
Arctic Snow
000A
Cool White
000C
Deep Red
000D
True Blue
000E
Tangerine
000F
Polar White
000G
Absolute Black
000H
Ocean Grey

Colours for designer laminate DcorColour

Applications
Internal partitions

. 

Wall panelling

. 

Lift lobbies

. 

Fully framed doors

. 

Feature panelling in schools,


restaurants and offices

. 

Furniture such as table tops,


desks, shelves, display cases

. 

Facades

. 

Skylights

. 

Atriums

. 

Sahara
sun
S SSS
Sahara
Sahara
sun
sun
Sahara
sun
Sahara Sun

Sahara
sun
SSSS
Sahara
sun
Sahara
Sahara
sun
sun

Golden
light
NS
Golden
Golden
light
light
NS
NS
Golden
light
NS
Golden Light

Golden
light
NS
Golden
light
NS
Golden
Golden
light
light
NS
NS

True
blue
NS
True
True
blue
blue
NS
NS
True
blue
NS
True Blue

True
blue
NS
True
blue
NS
True
True
blue
blue
NS
NS

Sapphire
S SSS
Sapphire
Sapphire
Sapphire
Sapphire

Sapphire
SSSS
Sapphire
Sapphire
Sapphire

Aquamarine
S SSS
Aquamarine
Aquamarine
Aquamarine
Aquamarine

Aquamarine
SSSS
Aquamarine
Aquamarine
Aquamarine

Arctic
snow
NS
Arctic
Arctic
snow
snow
NS
NS
Arctic
snow
NS
Arctic Snow

Arctic
snow
NS
Arctic
snow
NS
Arctic
Arctic
snow
snow
NS
NS

Absolute Black

Maximum size
Maximum width @ 2440mm

. 

Thickness
6.38mm to 13.52mm (dependant
onnumber of interlayers required)

. 

Deep Red

Deep
red
NS
Deep
Deep
red
red
NS
NS
Deep
red
NS
Deep
red
NS
Deep
red
NS
Deep
Deep
red
red
NS
NS

Ruby Red

Coral Rose

Evening Shadow

Smoke Grey

Ruby
red
S SSS
Ruby
Ruby
red
red
Ruby
red

shadow
S SSS Smoke
Coral
rose
NS
grey
NS
Evening
Evening
shadow
shadow
Coral
Coral
rose
rose
NS
NS Evening
Smoke
Smoke
grey
grey
NS
NS
Evening
shadow
Coral
rose
NS
Smoke
grey
NS

Ruby
red
SSSS
Ruby
red
Ruby
Ruby
red
red

shadow
SSSS Smoke
Coral
rose
NS
grey
NS
Evening
shadow
Coral
rose
NS
Smoke
grey
NS
Evening
Evening
shadow
shadow
Coral
Coral
rose
rose
NS
NS Evening
Smoke
Smoke
grey
grey
NS
NS

Cool White

Cool
white
S SSS
Cool
Cool
white
white
Cool
white
Cool
white
SSSS
Cool
white
Cool
Cool
white
white

Polar White

Pure
white
NS
Pure
Pure
white
white
NS
NS
Pure
white
NS

How to specify

Pure
white
NS
Pure
white
NS
Pure
Pure
white
white
NS
NS

. 

Select glass name


Viridian DcorColour
Select thickness process
6.38mm to 13.52mm Laminated
7.52mm to 13.52mm
Toughened/Laminate

. 

Tangerine

Ocean Grey

Polka
dot
NS
Polka
Polka
dot
dot
NS
NS
Polka
dot
NS

Mini
dot
NS
Mini
Mini
dot
dot
NS
NS
Mini
dot
NS

Wide
band
NS
band
NS
Wide
Wide
band
band
NS
NS Narrow
Narrow
Narrow
band
band
NS
NS
Wide
band
NS
Narrow
band
NS

Mini
band
NS
Mini
Mini
band
band
NS
NS
Mini
band
NS

Square
NS
Square
Square
NS
NS
Square
NS

Mini
hole
NS
Mini
Mini
hole
hole
NS
NS
Mini
hole
NS

Polka
dot
NS
Polka
dot
NS
Polka
Polka
dot
dot
NS
NS

Mini
dot
NS
Mini
dot
NS
Mini
Mini
dot
dot
NS
NS

Wide
band
NS
band
NS
Wide
band
NS
Narrow
band
NS
Wide
Wide
band
band
NS
NS Narrow
Narrow
Narrow
band
band
NS
NS

Mini
band
NS
Mini
band
NS
Mini
Mini
band
band
NS
NS

Square
NS
Square
NS
Square
Square
NS
NS

Mini
hole
NS
Mini
hole
NS
Mini
Mini
hole
hole
NS
NS

Cross
NS
Cross
Cross
NS
NS
Cross
NS

Weave
NS
Weave
Weave
NS
NS
Weave
NS

Linen
NS
Linen
Linen
NS
NS
Linen
NS

Honeycomb
NS
Honeycomb
Honeycomb
NS
NS
Honeycomb
NS

Sandstone
NS
Sandstone
Sandstone
NS
NS
Sandstone
NS

Cross
NS
Cross
NS
Cross
Cross
NS
NS

Weave
NS
Weave
NS
Weave
Weave
NS
NS

Linen
NS
Linen
NS
Linen
Linen
NS
NS

Honeycomb
NS
Honeycomb
NS
Honeycomb
Honeycomb
NS
NS

Sandstone
NS
Sandstone
NS
Sandstone
Sandstone
NS
NS

This colour swatch is to be used as a guide only. The final glass colour may differ from these printed swatches.
*Subject to volume requirements.

viridianglass.com

Digiglass

Decorative

Digiglass uses a computer-based digital imaging

Create any custom graphic

system that is exceptionally efficient and versatile,

DigiGlass is created by printing a high resolution

opening up a broad range of application

digital or photographic image directly onto DuPont

possibilities. This digital system requires no tooling,

PVB interlayer creating a Grade A laminated

so making changes to refine your end product are

safety glass. The process is the only one of its kind

fast and simple. Digiglass also gives you excellent

and is the only decorative glass product backed

colour options such as complex skin tones of a

by a major supplier of PVB, DuPont.

group photo, or subtle tonal differences within


a scene for dramatic effect.
All Digiglass product meets AS2208 Grade A Safety
Glass standards making it the ideal solution for

Scaling, Resolution and File information:


Optimal image scaling at 1:10
Image file quality 150 to 250 DPI per sq inch
at actual size

. 

most applications. The image is in the interlayer

. 

between two layers of glass, so cleaning is simple

. 

and the image is protected from solvents and


cleaning agents.

Digiglass

Electronic files acceptable


FTP site facility available for clients for ease
of file transfer

Format
Most PC or MAC based design applications

Applications
.

Staircases

Balustrades

Your choice of transparency

Lift car interiors

DigiGlass lets you create a wide range of

Showerscreens and interiors

transparency levels within a single laminate pane.

Building facades

You can have solid colours or high density art

Entries

or photography in one part of the image and

Partitions

complete transparency elsewhere. You have

Splashbacks

including PDF.

complete control with the opacity levels required.


Website www.digiglass.com.au

Maximum size
. 2250 x 5100mm
Thickness
7.52mm, 9.52mm, 11.52mm,
13.52mm, 17.52mm, 21.52mm,
25.52mm, Multi laminates
available also

. 

How to specify
Select thickness process
7.52mm to 25.52mm. Specify
edge work, heat soak treatment,
toughening, heat strengthened,
annealed.

. 

Options
Available with any glass combination
including Low Es, performance glass,
Dcor satin, mirror, low iron, heat
strengthened, toughened

Bushfire Protection
Viridian bushfire resistant glass is
designed to help home owners
balance the need for bushfire
safety with aesthetic freedom
and the increasing requirements
for energy efficiency demanded
by the Building Code.

viridianglass.com

Bushfire
Protection
PyroGuard 40

86

Bushfire
Protection

Bushfire resistant glass

PyroGuard 40

Changes incorporated in to AS3959;

requirements of AS1530.8.1 it is suitable to be used

Construction of Building in Bushfire-Prone Areas

for Bushfire Attack Levels (BAL) up to and including

has provided a pathway for a deemed to satisfy

BAL 40. Viridian PyroGuard 40 is not designed to

and alternative solution to glazing based on a

be used in BAL Fire Zone (BAL FZ).

BushFire Attack Level (BAL) rating. The deemed to


satisfy approach prescribes glazing and bushfire
resistant shutters and/or specific metal screens
to the glazing area as the BAL moves through

sought from the relevant authorities and the


window system manufacturer on suitability.

BAL 12.5 through to BAL 40 (refer to AS3959 for

Viridian PyroGuard 40

specific details). For consumers the presence

Viridian PyroGuard 40 bushfire resistant glass is a

of either or both of these elements may provide

specially processed insulated glass unit. It includes

an unsightly and undesirable additional feature

an ultra-thin coated glass that reduces the transfer

to the buildings external appearance.

of radiant heat from the bushfire front through the

AS3959 also provides an alternative solution using


specifically tested and certified window systems
in lieu of the deemed to satisfy provision. By
successfully completing the test procedures in
AS1530.8.1 alternative window systems can be
installed without the need for bushfire resistant
shutters and/or specific metal screens to the

glass unit to the inside of a building. When subjected


to radiation levels of up to 40kW/m,2 less than 4%
of the radiant heat is transferred through a window
glazed with Viridian PyroGuard 40. Figure 1 shows
a typical test for Viridian PyroGuard 40 to resist
radiant heat exposure of under 40kW/m.2 This assists
in providing protection to combustible materials
such as curtains and furnishings within the building.

glazing area up to and including BAL 40.

Viridian PyroGuard 40 is a proprietary bushfire

When a Viridian PyroGuard 40 bushfire

resistant glazing system available only through

resistant insulated glass unit is glazed as a part

authorised Viridian processing facilities.

of a successfully tested window system to the

AS1530.8.1 test profile


Heat flux 365mm from window

40

Heat Flux (KW/m2)

35
30
25
20
15
10
5
0

Time (mins)

Figure 1
Radiant heat exposure*

viridianglass.com

Specific advice on the application should be

10

Bushfire
Protection

Bushfire resistant glass


Energy management

to bushfire attack in designated bushfire-prone

Viridian PyroGuard 40 provides significantly

areas, but does not guarantee that a building

better insulation performance than standard

will survive a bushfire event on every occasion.

single paned glass, to improve the thermal

Refer to AS3959 for specific details. It is imperative

comfort for occupants in the normal seasonal

that home owners contact fire authorities to

operation of the building. Viridian PyroGuard 40 is

obtain all relevant information on how to best

an insulated glass unit which features two pieces

manage bushfire risks. Viridian PyroGuard 40

of glass separated by a hermetically sealed

bushfire resistant glass in a successfully tested

argon gas filled gap. This forms a transparent

and certified window system is only one part of a

insulating barrier between the interior of the

combination of strategies needed to reduce the

building and the outdoors, significantly reducing

risk of ignition from a bushfire while the fire front

the rate of transfer of heat. Viridian PyroGuard 40

passes.

is a safety glass which is manufactured to comply


with AS2208 Safety Glass in Buildings.
Bushfires are highly unpredictable in their intensity,
duration and progress. The ability of a building to
survive a passing bushfire is not solely dependent
on the ability of glass used in windows and doors

PyroGuard 40

Identifying Viridian PyroGuard 40


Your Genuine Viridian PyroGuard 40 is identified
by a stamp in the bottom right hand corner of

Maximum size

each of the two glass panes of the insulated

. 

glass unit as shown below:

Refer to window manufacturers test


certificate for maximum window size

Minimum size

to withstand radiant heat.

350 x 250mm

. 

A number of other factors are critical, including


wall cladding, roofing material and absence of
combustible material near the house.
AS3959, Construction of buildings in bushfire-prone
areas, states that it is designed to improve the
performance of the buildings when subjected

Inner Pane
Specially
toughened
and processed
coated float
glass
Outer Pane
Specially
toughened
and
processed
float glass

Figure 2
Viridian PyroGuard 40 IGU

Gap

Structural
The standard for quality and vision.
Structurally glazed products can
enhance performance without
compromising natural light.

viridianglass.com

Structural
ThermoTech Point Fixed IGUs
90
Structural Glazed Systems
92
Profilit93
Balustrade System
95

Structural
ThermoTech
Point Fixed IGUs

Maximum energy savings,


superior interior comfort
Viridian ThermoTech Point Fixed IGUs

ThermoTech Point Fixed IGUs, supported by

continuethe theme of performance glass

spider fittings, glass fins, or cable trusses allow for

assisting in reducing the running costs of

less obtrusive framing systems than the traditional

buildings. For years, the building industry has

framed glazing techniques.

been conscious of installing IGUs into the


towers of multi-storey office buildings. Without
compromising natural light but enhancing
performance, ThermoTech Point Fixed IGUs
can now insulate large foyers of office buildings,
airports, museums, art galleries, grandstands
and so on.

viridianglass.com

ThermoTech Point Fixed IGUs incorporate a TPS


spacer between the glass panels with a silicone
secondary seal. Combined with patented fixed
or ball jointed IGU fittings, the flexibility of the TPS
spacer and fitting allow for the IGU to move under
wind pressure without compromising the IGU seal.

Structural
Available in the following combinations*
12mm/12arg/12mm IGU 4 pin supports
Wind pressure, kPa ULS

Wind pressure, kPa ULS

8mm/12arg/8mm IGU 4 pin supports

ThermoTech
Point Fixed IGUs

Panel width, mm

10mm/12arg/10mm IGU 4 pin supports

Typical 4 Pin Fixings

Wind pressure, kPa ULS

Panel width, mm

Applications
Podiums

. 

Curtain walls

. 

Panel width, mm

Ground floor atriums

. 

Airports, museums, art galleries

. 

1) The IGU is fixed on four corners with articulated bolt fittings 100mm from the edge of the glass.
2) Deflection is limited to span/100 or 1.5 times the spacer width maximum in the centre of the unit.
3) These charts are provided as a general guide for information purpose only.
4) Edge deflection is recommended to be no more than span over 150.

Sporting grandstands

. 

Maximum size
4500 x 2700mm

. 

IGUs available in 4 pin, 6 pin


and 8 pin support

. 

Glass combinations available


Processed into toughened or toughened
laminated

. 

Clear

. 

Toned

. 

Heat soak treatment is strongly recommended


to toughened glass (see heat soak treatment
page 120)

. 

Low-Emissivity

. 

High performance coatings

. 

Maximum thickness
8mm glass/12mm argon
spacer/8mm glass

. 

12mm glass/12mm
argon spacer/12mm glass

. 

10mm glass/12mm
argon spacer/10mm glass

. 

Estimated optical and solar performance data


Glass type

Nom. Thk
(mm)

Visible Light %
Trans.

U-Value
W/sq.m.K

SHGC

10clr/12arg/10clr

32

76

2.5

0.65

10grn/12arg/10clr

32

57

2.5

0.37

10gry/12arg/10clr

32

22

2.5

0.36

10clr_sungy(2)/12arg/10clr

32

58

1.8

0.47

10grn/12arg/10clr_sungy(3)

32

44

1.8

0.32

10gry/12arg/10clr_sungy(3)

32

17

1.8

0.30

IGU

For other thicknesses and data contact Viridian Technical Services.

Technical specifications
Project specific designs are also
available on request.
*
All performance data is calculated
using LBNL Windows 5.2 software based
on AFRC 1002001 conditions and is
centre of glass value.

Structural
Structural Glazed
Systems

Total vision systems for doors


and entrances
Description

Design considerations

Frameless glass doors provide clear, uninterrupted

The design can incorporate double doors and

vision into a building making them ideal for

sidelights. The maximum sizes are based on

shopfronts and office entrances. Viridian

the largest available toughened glass for a

Structural Glazed Systems are an ideal choice

single sidelight. Doors up to 2400mm in height

and can be supplied in clear, grey, bronze, green

are suitable for design windloads of 1.0kpa.

and blue colour options. Door hardware can be

Higher windloads and door heights may lead to

selected from several manufacturers and custom

unacceptable deflections. The exposed edges

products and finishes are also available. Standard

ofthe door heights are vulnerable to damage

finishes include polished brass, chrome, stainless

and consequent breakage, especially in areas

steel and powder coat colours. The doors are

of high traffic with trolleys or shopping carts

supplied in finished form including all holes

for example. For additional safety, a Viridian

and edge work with special cut-outs to accept

toughened laminated product combination

specified handles, pivots and locks.

should be considered. For more information


onthese systems, please contact Viridian

Applications
Shop fronts

. 

Office entrances

. 

Options
Available in clear glass and in a
variety of toned finishes

. 

Range of hardware options

. 

viridianglass.com

Technical Services.

A practical, durable solution


for walls and facades
Description

Product details

Profilit is a self-supporting glazing system

The channels are manufactured in single lengths

of U-shaped profiled glass and is supplied as

of 3.0m to 5.8m. Depending on windload, they

a glass and framing system for facades and

can span up to 3.05m in single or 4.35m in

internal partitions. This highly durable product

double configuration between supports. Please

allows diffused light to enter the building while

consult with Viridian Technical Consultants for

presenting a translucent external appearance.

details on spans and safety requirements. The

Profilit can be installed as a single wall, or a

appearance of the glass presents a subtle texture

double wall for additional sound and thermal

providing light diffusion and privacy. The joints

insulation. The joints between the panels can

between the panels are silicone sealed.

be configured vertically or horizontally.

Structural
Profilit

For example: Profilit K25


Dimensions width 262mm, flange 41mm

. 

Light transmission single shell 86%,


double shell 75%

. 

Insulation U Value single shell 5.6,


double shell 2.8

. 

Sound transmission single shell 22dB,


double shell 38dB

. 

Applications
Facades

. 

Interior partitions

. 

Maximum length
5.8m

. 

viridianglass.com

Balustrades with unrestricted views

Structural

Description

Important considerations

This free standing glass balustrade system uses

. 

Balustrade System

balustrades. The system minimises framing,


creating light, clear spaces. Alternatively, VTough
and Viridian VLam glass can be bolt-fixed or
installed within framed sections.
Technical details
The Viridian Balustrade System consists of
10mm, 12mm or 15mm toughened glass that
may also require laminating depending on
application. The glass is set upright in a groove
instructural concrete or a steel channel.
The glass panels are located on neoprene setting
blocks and a special non-shrink grout is used.
The grout is capped off with a silicone cap.
The channel must be designed to resist the
twisting movements applied to the balustrade.

If the balustrade is protecting a difference


in level of more than 1000mm, a separate
handrail capable of withstanding the design
load independent of the glass must be used.
Please consult with Viridian for details.

. 

The designer must determine that in the case


of accidental or deliberate damage, any
falling glass can cause no public danger.
In these situations Viridian recommends the
use of a toughened laminated glass or fully
framedlaminated glass.

. 

Exposed edges of laminated glass are not


recommended.

. 

Viridian recommends all toughened glass used


in frameless or bolted structural balustrades
be specified as Viridian heat soak treatment.
Note: this is a Viridian warranty requirement.

. 

Benefits

Applications
Windbreaks

. 

Balconies

. 

Stairs and landings

. 

Clear, unrestricted views

. 

Pool fences

Options

Glass panels provide wind break

. 

Can be designed for bolted or freestanding


applications

. 

. 
. 

VFloat clear, grey, bronze, green,


Viridian SuperBlue
SuperClear TC for ultra clear
appearance
Seraphic design for screen printed
decorative options

. 

Detail
Handrail not supplied by Viridian.
AM
 inimum distance from glazing
channel to concrete perimeter.
10 and 12mm glass to design.
BH
 eight of balustrade
to regulations.

C1
 0, 12 and or 15mm
toughened glass panel
(heat soak treatment).

DC
 oncrete channel continues
the length of the balustrade,
alternative pressed steel
channel may be used.

E Silicone topping.


E
65mm

produce clean, dramatic and cost effective

90mm

the structural strength of Viridian VTough to

Standards Australian Standard AS1288 and New


Zealand Standard NZS4223 with design loads
from AS/NZS1170.1 must be complied with.

FC
 ontinuous
non-shrinkable grout.
G Neoprene setting
block 100mm long
at 760mm centres.

F
G

25 10

*Maximum panel
width = 2500mm

45
Note A range of proprietary post and cantilevered
balustrade systems are available in New Zealand only.
Please contact Viridian New Zealand for further details.

Product range*
Thickness (mm)
10

12

15

19

Clear

SuperClear TC

Seraphic

Grey

Product

Storm
Certified cyclone resistant glass
that allows a building to remain
habitable after a cyclone passes.

viridianglass.com

Storm
StormGuard99

viridianglass.com

Protection against natures most


powerful storms
Viridian StormGuard cyclone resistant glass

Features and benefits

has been specifically designed and tested for

. 

buildings inthe Australian and South Pacific

. 

Clear vision without the need for storm shutters

with the conditions as described by the

. 

expanded requirements of the most recent

. 

release of AS/NZS1170.2. It is also suitable

. 

Tested to the requirements of AS/NZS1170.21


Grade A safety glass
Even when cracked by debris impact,
StormGuard will still resist the design fatigue
wind pressure to levels in excess of 15Kpa
for some products2

wherever buildings require protection from


strong winds and airborne debris.
Description

. 

StormGuard cyclone resistant glass is a laminated

. 

safety glass that incorporates a higly effective

Range of tones and solar control options


Security, noise reduction, UV protection

interlayer to resist penetration from flying debris


such as timber, which can be carried by strong
cyclonic winds. Even if the glass is impacted and
cracked, it still retains its weather-tight capability,
a cyclone passes.
StormGuard cyclone resistant glass is suitable for
buildings which are required to perform a post
disaster function such as hospitals, emergency
services, communications facilities, etc. It is also
suitable for all other buildings subject to the strong
winds, including commercial buildings and hotels,
as well as domestic homes.

StormGuard

Protection from the weather even if glass


is impacted

cyclone prone regions. This product complies

allowing the building to remain habitable after

Storm

Tested to withstand a 4kg piece of timber


100mm x 50mm cross section, striking the
glassat up to 40m/s, 8mm diameter steel
striking ball at up to 40m/s and up to full
ultimate wind pressure in a fatigue sequence
after the impact tests.
 lass sizes and thicknesses vary depending
G
on building type and cyclone exposure.

Note: The glass needs to be incorporated into


a window frame capable of retaining the glass
under impact and against both positive and
negative wind cycles.

Applications
Hospitals

. 

Hotels

. 

Emergency services

. 

Defence and government buildings

. 

Shops and commercial premises

. 

Apartment blocks

. 

Domestic premises

. 

Regulatory requirements can vary with region


and application, check local requirements.

Glass thickness
Varies with application

. 

How to specify
Select glass name
Viridian StormGuard

. 

Select thickness process


Laminated determined by
application

. 

Select colour

. 

This glass must be glazed into a


windowframe designed to provide
appropriate glass retention.

Security
With state-of-the-art security comes
peace of mind. Viridian security
glass offers transparency, beauty
and strength while performing the
many other functions that only
glass can fulfil.

viridianglass.com

Security
Observa104
IntruderGuard105
AssaultGuard105
AssaultGuard Ultra
106
JailGuard109
BulletGuard110
Bomb & BlastGuard
113
MineGuard113

viridianglass.com

Security glass for all


threat levels
Whether its a house window, a shop front or a
security facility, Viridian has a security glass that
provides the benefits of daylight and transparency
with the peace of mind of security all day,
every day.
Security glass has been developed to resist:

Bomb blast
Glass designed to resist bomb blasts remains in
place, substantially reducing injury from flying or
falling glass. Additionally, the building envelope
will remain intact minimising or eliminating interior
damage. Proprietary glass and framing systems

Physical attack from burglary and forced entry

have been tested to determined blast loads for

Ballistic attack

aspecified duration.

. 
. 

Bomb blast

Laminated safety glass even as thin as 6.38mm

. 

Electronic eavesdropping

has been shown to reduce falling and flying glass

Viridian security glass comprises multiple layers

resulting from bomb blast. For more details on fully

of glass and special or thick interlayers, used for

specified bomb blast glass and frame restraint

durability and resistance to attack. The thickness

design, please contact Viridian Technical Services.

. 

Security

and type of interlayer provides resistance to


penetration. The interlayer may be thick PVB

Did you know?

or a special ionoplast or polycarbonate interlayer

Viridian has security products to protect


against domestic burgulary right
through to anti-personnel mines.

for strength.
Security glass can be configured to include
solarand thermal control, Viridian Renew self
cleaning glass, Viridian Observa oneway vision
and decoration.
As with all security glass, the window frame system
must also be capable of withstanding attack and
retaining the glass.
Ballistic attack
The range of glass available correlates to the
level of ballistic attack performance defined
in Australian Standard AS2343. The glass
construction is a combination of all glass or glass
and polycarbonate and is designed to provide
transparency, abrasion and bullet resistance.
The glass thickness range is 32mm to 45mm and
is designed to resist an attack from a specified
distance for a limited number of strikes. The natural
green tone of the glass is apparent at this thickness
and can be minimised by specifying Viridian
SuperClear TC For test details, performance
and maximum sizes, please contact Viridian
Technical Services.

Security
Observa

The security advantages


areall one way
Description

Lighting conditions

Viridian Observa is an observation mirror offering

To achieve privacy for observers, a light ratio of

high quality one-way vision that effectively

1:7 is recommended, where the subject side is

provides discreet, unobtrusive monitoring. It has

brightly illuminated and the observer side is dimly

the appearance of a mirror on the subject side,

lit. Bright lighting sources must be avoided in the

while providing privacy for observers. It is also

observers area and spotlights directed away from

laminated to provide protection from human

the Observa surface. We recommend using dark

impact and reduces noise transmission.

furnishing colours and that dark clothing be worn

Installation

How to specify
Select glass name
Viridian Observa

. 

Select thickness process


8.76mm

. 

in the observation area.

Observa is normally used for internal applications.

Note: For external applications and natural

Glazing should be in accordance with the

lighting situations where variable lighting

Australian Standard AS1288, New Zealand

conditions exist, the Observa performance

Standard NZS4223 and Viridian recommendations

canbe affected.

for laminated glass.

Benefits

The reflective surface must be installed to the


subject side.

A safe and effective observation mirror

. 

fordiscreet monitoring
Appearance of a mirror

. 

Laminated for safety

. 

Low observer area lighting compared


tosubject area

. 

Maximum size
. 

3660 x 2440mm

Please note
A light ratio of 1:7 is recommended.

viridianglass.com

Coating protected from scratching

. 

Noise attenuation

. 

Protection for people


and property
Viridian IntruderGuard is a security glass for

A barrier to forced entry

residential buildings and specialised commercial

The range of Viridian AssaultGuard glass is an

applications.

economical method of providing a barrier to

Description

forced entry while providing transparency and

IntruderGuard looks like normal glass yet provides


a barrier to forced entry that is 20 times harder
to break through than standard float glass and it
achieves this without making a building look like a
fortress. IntruderGuard is specifically developed to
offer a resilient and enduring barrier for vulnerable
entry points across a broad range of applications.

Security
IntruderGuard
AssaultGuard

clarity. AssaultGuard incorporates interlayers


four times the thickness of those manufactured
in standard laminates and is designed to resist
attack from a variety of hand tools used for
forced entry such as hammers, crowbars and
wood splitters. AssaultGuard is typically used in
commercial applications such as vulnerable
shopfronts, windows and doorways susceptible

IntruderGuard is a 7.52mm laminated glass and

to break in. It is also used in a variety of other

provides extra resistance to penetration because

at risk applications such as pay booths, jewellery

its interlayer is four times thicker than normal

counters and display counters, providing enough

laminated glass.

resistance against smash and grab theft.

Viridian IntruderGuard applications

Features and benefits

Viridian AssaultGuard Ultra can be used if a

. 

high level of security is required (refer to page 106).

Maximum size

IntruderGuard like all laminated glass also


provides other benefits:
Improved resistance to penetration upon
breakage safer for families.

. 

Features and benefits


Resists penetration and forced entry glass
may break but interlayer retains integrity and
continues to act as barrier.

. 

Reduces fading of furnishings by absorbing


99% of UV radiation.

. 

Reduces unwanted noise compared to


standard glass.

. 

. 

. 

Available in clear, tint or Viridian ComfortPlus.

. 

IntruderGuard should be incorporated with


window frames and locks of sufficient strength.

Withstands repeated blows from heavy objects


such as bricks, hammers and crowbars.
Provides UV protection, noise reduction and
is a Grade A safety glass to AS/NZS2208.

Domestic and low level commercial

3660 x 2440mm

. 

How to specify
Select glass name
Viridian IntruderGuard

. 

Select colour
PVB Interlayer options include:
Clear, Grey, Bronze, Green,
Cool Blue, Soft White and
White Translucent

. 

Can be supplied with solar control and privacy.

. 

Consider incorporating Viridian SuperClear TC


to enhance the high light transmission often
required in retail applications.

. 

Viridian AssaultGuard applications


Shop fronts and display counters

. 

Maximum size
3660 x 2440mm

. 

How to specify
Select glass name
Viridian AssaultGuard

. 

Select thickness process


9.52mm Laminated
11.52mm Laminated
13.52mm Laminated

. 

Select colour
PVB Interlayer options include:
Clear, Grey, Bronze, Green,
CoolBlue, Soft White and
White Translucent

. 

Security
AssaultGuard Ultra

Creative design solutions for


advanced security barriers
Viridian AssaultGuard Ultra is a speciality glass
primarily developed for use in facilities such as

Viridian AssaultGuard Ultra 10


Minimum Security Glass

police stations, juvenile justice and mental health

AssaultGuard Ultra 10 is the base product

facilities. Products within the AssaultGuard Ultra

in the range and ideal for use in low to medium

range are designed to withstand a variety

risk facilities, such as observation or holding

of attacks.

cells, police station detention areas, mental

This product is a composition of thermally


toughened glass (VTough) and a specialised
interlayer. It has demonstrated a strong resilience
to concentrated attacks.
Viridian JailGuard can be used if maximum
security is required (refer to page 109).

health institutes, banks, high-risk display cases


(museums, art galleries, etc) and pay offices.
Viridian AssaultGuard Ultra 12
Medium Security Glass
AssaultGuard Ultra 12 is the mid-range
product in the range.
It is typically used in medium to high risk areas

AssaultGuard Ultra products are manufactured

in facilities as well as juvenile justice centres,

using a variety of glass types and thicknesses

remand centres, high risk police detention

combined with specialised security interlayers.

areas and mental health facilities.

(Spall films can be applied post installation


to non-Low E coated glass products).

Viridian AssaultGuard Ultra 14


Premium Security Glass

Additionally, if stringent energy efficiency

AssaultGuard Ultra 14 is the highest performing

requirements are specified, Viridian AssaultGuard

product in the range.

Ultra can be supplied in a range of toned


and Low E combinations or combined with our
ThermoTech Insulated Glass Unit (IGU) range.

It is specifically designed for applications requiring


client observation where excellent integrity of
product is required. This maximum security glass
is typically used in maximum risk areas in facilities
such as juvenile justice centres, remand centres
and acute or forensic mental health facilities.

Project: Canberra Hospital Adult Mental Health Facility. Photographer: Brian Steele.

viridianglass.com

Security
AssaultGuard Ultra

Product range
Clear

Non Coated Range

Low E Coated Range

Neutral

Green

Super
Green

Grey

Maximum
Size

AssaultGuard
Ultra 10

2440 x 1220

AssaultGuard
Ultra 12

2440 x 1220

AssaultGuard
Ultra 14

3650 x 2130

AssaultGuard
Ultra 10
Low E

2000 x 1000

AssaultGuard
Ultra 12
Low E

2440 x 1220

AssaultGuard
Ultra 14
Low E

Viridian AssaultGuard Ultra applications


Observation or holding cells

. 

Police station detention areas

Mental Health facilities

Banks

3500 x 2130

Features and benefits

. High-risk display cases


(museums, art galleries, etc)

Conforms to AS/NZ2208 for safety


glazing material.
.

How to specify

May be specified in a range of single


and double glazed configurations.

. 

Select coated or uncoated

. 

Select thickness process


Toughened/Laminate
Nonimate the level of security
to determine thickness

. 

Can be used for both internal and


external applications.

. 

Internal testing coupled with market recognition


indicates prolonged impact resistance in
non-rated security applications where design
considerations may prevent the use of
ordinary glass.

. 

Select colour
If required

. 

Now part of a standard product range,


making it easier to specify and purchase.

. 

Blocks 99% of unwanted UV (Ultra Violet) light.

. 

Project: Canberra Hospital Adult Mental Health Facility.


Photographer: Brian Steele.

viridianglass.com

Creative design solutions for


advanced security barriers
Viridian JailGuard is a specialised security

Features and benefits

glass primarily geared for use in correctional

. 

facilities such as police stations, remand centres,


juvenile justice facilities and jails. Products within
the JailGuard range are designed to withstand
a variety of attacks from hand tools and typical
implements such as brooms, mop buckets,
billiard balls and other objects found within
correctional institutes. Simulated attack conditions
using axes, wood splitters, crowbars and other

JailGuard is tested to HPW-TP-0500.02 and .03


and Opus (NZ) specification can be organised
to be tested to specific requirements.

Security
JailGuard

Conforms to AS/NZS2208 for safety glazing


material.

. 

May be specified in a choice of configurations


clear, translucent, toned, Observa.

. 

Can be used for both internal and external


applications.

. 

hand tools have shown products within the


JailGuard range capable of resisting penetration
for extended periods.
JailGuard products are manufactured using a
variety of glass types and thicknesses combined
with high-end security interlayers. JailGuard can
also incorporate low spall films if required.
For further information please contact
Viridian Technical Services.

How to specify
Select glass name
Viridian JailGuard

. 

Select thickness process


Toughened/Laminate
Nominate the level of security
todetermine thickness

. 

Select colour
If required

. 

Security

Glass to meet any ballistic threat

BulletGuard

Bullet resistant glass has become increasingly

What makes BulletGuard unique?

more advanced over time. Glass thickness

One of the keys to the success of BulletGuard

and weight have been reduced and light

products is weight. In many applications where

transmissions, as well as visual clarity, have

bullet resistant glass is required it is preferable

beenimproved.

to keep weight to a minimum, especially in

Nowhere are these innovations better

armoured and defence vehicles. Even in building

demonstrated than with the Viridian

installation it is preferable to keep weight to a

BulletGuard product range.

minimum, as additional weight requires additional

The Viridian BulletGuard product range is used


in banks and payroll institutes, embassies and
government offices, police stations, high profile
public buildings, armoured and special
defence vehicles.
BulletGuard is a highly specialised range of
products manufactured with the specific purpose
of resisting penetration by projectiles discharged
from firearms. All products within the BulletGuard
range are manufactured to meet the stringent
requirements of the Australian and New Zealand
Standard AS/NZS2343. Viridian is also renowned
for the development of specialised bullet resistant
glass solutions, designed to deal with calibre
ranges and ballistic threats covered in the special
glass clause of the Australian Standards.
The BulletGuard range of products are multiple
compositions consisting of glass, highly
specialised scratch resistant polycarbonates,
polyurethane, specifically developed security
interlayers and security films.
The components used in the manufacture
of BulletGuard products retain a high level
of light transmission and a high degree
of visual integrity following an attack.

viridianglass.com

structural support. With an ever increasing diversity


of product types, complex glass standards
and regulatory building code changes, correct
product selection is becoming more difficult and
ever more important.
Installation instructions
1. Allow adequate edge clearance for glazing,
normally 6mm all round.
2. Allow for a minimum of 15mm edge cover.
Viridian recommends 20mm.
3. Ensure the frame and supporting structure
is strongly constructed to provide adequate
protection for the glass. It is most important to
consider the weight of the glass used and to
provide suitable resistance to penetration to
edge attack. The frame and the glass should be
considered together as a bullet resistant unit.
4. S etting blocks, 6mm minimum, and distance
pieces, 2mm minimum, are essential. They
must be installed to prevent glass contact with
the frame. Avoid glass to metal contact.
5. The glazing system must not allow water traps
to occur.

Security
BulletGuard

Performance data
Attack level

G0 /G1

G2

S1

R1

R2

Weapon and
calibre

Ammunition

Handgun

10.2g
soft point

357 Magnum

semi-jacketed, flat nose

Handgun

15.6g soft point

44mm
Magnum

semi-jacketed, flat nose

Shotgun 12
gauge

Weight (kg/m2)
approx.

3m

57.84

3m

70.36

3m

93.40

10m

78.77

10m

120.73

12 gauge 70mm
28.35g
single slug

Rifle 5.56mm

M 193 5.56

3.6g

3.6 full
metal case

Rifle 7.62mm

Range

Number of
strikes

NATO standard 7.62mm


9.3g full metal case

How to specify

Notes: Chart based on Standards. The standard defines three broad attack level categories: 1. G Resistant to handgun attack. 2. S Resistant
to shotgun attack. 3. R Resistant to rifle attack. R1. Rifle 5.56mm S1. Shotgun 12 gauge G2. Handgun 44 magnum R2. Rifle 7.62mm.

Maximum size
2000 x 1000mm

. 

Please consult with Viridian Technical


Services to discuss specific
requirements for BulletGuard
applications.

GO. Handgun 9mm

G1. Handgun 357 magnum

G2. Handgun 44 magnum

S1. Shotgun 12 gauge

G0. Handgun 9mm

R1. Rifle 5.56mm

R2.Rifle 7.62mm

G2. Handgun 44 magnum

viridianglass.com

Glass solutions for the most


extreme security risks
Viridian Bomb & BlastGuard

Viridian MineGuard

Changes in the geopolitical climate have

MineGuard is a highly specialised bomb and

created a dramatic increase in demand for

blast resistant product designed specifically to

bomb and blast resistant glass. Very real

protect military vehicles from the threat of anti

and seemingly random threats to personal

personnel mines.

security have caused governments, public and


private organisations as well as individuals to
reassess security.

Security
Bomb & BlastGuard
MineGuard

This highly specialised security glass has


been specifically tested against a simulated
PMN AP mine with a weight charge 240g TNT

Viridian is considered to be at the forefront of

hemispherical surfaces burst 90 and one metre

new product innovations in the manufacture and

from the blast centre.

supply of bomb and blast resistant glass. Bomb


&BlastGuard glass is a highly specialised range
of products manufactured to counter the threat
of bomb attacks. The product is available in a
range of thicknesses and includes the unique
Viridian MineGuard designed specifically for
military vehicle use.
Bomb & BlastGuard glasses are designed to
withstand the two specific assaults experienced
from bomb blasts, blast wave and bomb
casefragments.

How to specify
Select glass name
Bomb & BlastGuard or
Viridian MineGuard

. 

The level of threat must be


determined prior to developing
a specification. For assistance
please contact Viridian.

What makes Bomb & BlastGuard


glass unique?
Bomb & BlastGuard compositions are far
lighter than traditional bomb and blast resistant
glass solutions.
Bomb & BlastGuard are multiple compositions
consisting of glass, highly specialised
polycarbonates, polyurethane and specifically
developed security interlayers. The components
used in the manufacture of Bomb & BlastGuard
retain a high level of light transmission and
ensure visual image is maintained and free
fromdistortion.
Bomb & BlastGuard are typically used in
high-risk areas such as embassies and
government buildings, high profile public
buildings, armoured and specialised
defence vehicles.
Please consult with Viridian Technical
Services to discuss specific
requirements for Bomb & BlastGuard
or MineGuard applications.

Knowledge
Key knowledge and experience
is at your fingertips. We trust this
information will further inspire
architects and designers to use
this unique building material
inextraordinary ways.

viridianglass.com

Knowledge
How to specify clauses
Glass physical properties
Glass processing
Heat soak treatment 
Cleaning of glass
Standards and warranties
Energy Management
Performance Data
Performance comparison charts
Noise reduction solutions
Technical advice and CSR
Contact details

116
117
118
120
121
122
124
125
136
141
142

Knowledge
How to specify clauses
Solar control glass may be subject

. 

to thermal stress and should


therefore be thermally assessed
prior to installation.
Heat soak treatment is a destructive

. 

test, which reduces the likelihood


of spontaneous breakage by
converting impurities such as nickel
sulphide inclusions.
Heat Strengthening All glass which

. 

requires extra strength and thermal


resistance will be heat strengthened.
Heat strengthening increases the
strength of annealed glass. However
it is not a substitute for toughened
glass. Heat strengthened glass is not
a Grade A safety glass.
In the event of fracturing, heat

. 

strengthened glass will crack and


tends to remain in glazed position.
The glass shall comply with the

. 

following performance criteria:


Visible Light Transmission %

UValue Shading Coefficient (SC)


Solar Heat Gain Coefficient (SHGC)
All glass is to be selected and

. 

installed in accordance, but not


exclusively, with the following

Essential information for


glass specification
The Architectural Glass Guide has been designed
to provide Architects and Specifiers with a broad
range of information relating to glass types,
sizes, properties, behaviours and configurations
of Viridians product range. Due to the variety of
issues that are unique to each project, Viridian
strongly recommends that prior to commencing
your project you contact Viridian or your glazing
professional and discuss the unique requirements
of your project and the sustainability of individual
Viridian products and make-ups in specific
applications.
There are various key considerations when
designing and determining the appropriate glass
for an application. These range from the safety
requirements and breakage characteristics of the
glass type to the aesthetic or energy performance
of the product (see TechDirect bulletin C:01
Sustainability: Glass Selection & Terminology).
Viridian can help you to determine your glass
requirements based on your design, although the
design requirement and fitness for purpose falls
within the task of the designer.
When requesting assistance with glass specification
it makes it easier and quicker for Viridian to reply
to your request if the appropriate information
is supplied. The following lists the relevant
information required for the glass determination
in line with Australian Standard AS1288-2006 Glass
in Buildings Selection and Installation.

Australian and/or New Zealand

Vertical glazing

Standards

. 

Australian Standard AS1288

. 

Glass in Buildings Selection


and Installation
Australian Standard AS1170

. 

. 

Minimum Windloads on Structures


AS/NZS2208 Safety Glazing
Materials in Buildings
AS/NZS4666 Insulating Glass Units

. 

. 

AS/NZS4667 Quality Requirements


for cut-to-size and Processed
Glass

Further information
Please visit viridianglass.com or freecall
1800 810 403

Supply a drawing (elevation and plan)


Provide windload ULS & SLS for area under
consideration (if the application is external)
. Panel size Height (mm) x Width (mm)
. Details of how the panel is supported
. Internal or external application
. 

Roof glazing
Supply a drawing
Provide windload ULS & SLS for roof cladding
(different to that used for vertical cladding)
. Live load determine from AS1170 pt1. If unsure
which load is appropriate then consult the
Building Surveyor for advice
. Panel size distance up slope (mm) x distance
across slope (mm)
. Angle of panel measured from the horizontal
. Details of how the panel is supported, four
edges or two opposite edges
. Advise if the panel is supported on top of the
glass as well as under the glass
. Distance above the floor or ground (metres)
tothe highest point of the glass
. 
. 

Fin glazing
Supply a drawing
Provide windload ULS & SLS

. 
. 

viridianglass.com

Panel size Height (mm) x Width (mm)


Details of how the panel is supported at top
and bottom
. Internal or external application
. 
. 

Faceted glazing
Supply a drawing
Provide windload ULS & SLS
. Panel size Height (mm) x Width (mm)
. Details of how the panel is supported at top
and bottom
. Angle between adjacent panels
. Internal or external application
. 
. 

Balustrade
Supply a drawing
Advise difference in level the glass is protecting
. Provide windload ULS & SLS
. Live load determine from AS1170 pt1
If unsure which load is appropriate then
consult the Building Surveyor for advice
. Panel size Height (mm) x Width (mm)
. Details of how the panel is supported
. Details of how the handrail is supported
. Internal or external application
. 
. 

Floor glazing
Supply a drawing
Provide windload ULS & SLS
. Live load determine from AS1170 pt1
If unsure which load is appropriate then
consult the Building Surveyor for advice
. Panel size Height (mm) x Width (mm)
. Details of how the panel is supported
. Internal or external application
. 
. 

Pool fence
Supply a drawing
Provide windload ULS & SLS
. Panel size Height (mm) x Width (mm)
. Details of how the panel is supported
. 
. 

Thermal assessments
Viridian carries out thermal assessments for
its customers, free of charge. Please see
TechDirect bulletin P:01 Thermal Stress and
Thermal Fracture in Glass.

. 

Other considerations
Renew is a self-cleaning product designed
for organic material deposits on glass. It is
not effective at breaking down salt deposits
or other inorganic materials. It is therefore not
recommended for use in coastal or high salinity
areas where salt film build up is an issue.

. 

Haze Low E coated products exhibit a natural


haze characteristic which may be noticeable
when the glass is in direct sun or viewed against a
dark background. This is not a fault with the glass
but simply a characteristic of the Low E coating.

. 

Glass physical properties


General physical characteristics of soda, lime,
silica glass for building purposes
Density 2500 kg/m3

. 

Specific gravity 2.5 at 21C

. 

Coefficient of linear thermal expansion


88 x 10 -7/C. Glass has a much lower coefficient
of linear thermal expansion than most metals

. 

Thermal conductivity (K value) 1.05W/mC.


The difference between various types of flat
glass is small enough to be negligible

. 

Thermal endurance 6mm glass heated to


a higher temperature and plunged into water
at 21C will rupture at approximately 55C
differential. Toughened 250C differential

. 

Softening point 737C

. 

Annealing range 480C to 560C

. 

Strain point 523C

. 

Mean specific heat 1162 J/kgC


(25C to 850C)

. 

Modulus of elasticity 73 1 x 109 Pa


(HighFrequency Resonance at 20C)
Poissons ratio float glass 0.22 to 0.33
Glass conforms to the elastic theory to the point
of fracture

. 

Compressive strength 25mm cube: of the


order of 248 Mpa (not to be used for design
purposes, refer to local standards for glass
design)

. 

Tensile strength for sustained loading


19.3 to 28.4 Mpa. Determined as modulus
of rupture (glass strength is highly variable
so this information is not to be used for
design purposes. Refer to local standards
for glass design)

. 

Impact strength highly variable depending


on shape, hardness and velocity of impacting
object. Establish performance by specific
testing

. 

Hardness scale Mohs scale 5.5 to 6.5.


Knoop hardness 575

. 

Dielectric constant 6mm glass at


temperature
1,000,000,000 cycles per sec
10,000,000
cycles per sec
1,000
cycles per sec
10
cycles per sec

. 

Volume electrical resistivity 31 x 1011 m

. 

Refractive index 1.52 (at 590 nanometers).


Refractive index varies for light of different
wavelengths

. 

Thermal conductive (U Value) 5.9 W/m2K


6mm glass. Determined under AFRC 100-2001
environmental conditions (varies slightly with
thickness)

. 

Visible light transmission 87% 6mm Clear Float


glass. Varies with glass thicknesss and type

. 

Infra-red transmission relatively transparent to


short wave infra-red but opaque to long wave
infra-red (varies with glass type and thickness)

. 

Ultraviolet transmission float glass transmits


very little in the short wave length of the
ultraviolet band but transmission increases
as the boundary with the visible spectrum is
approached (transmission varies with glass
type and thickness)

. 

Chemical resistance glass will resist most


acids except hydrofluoric and at high
temperatures, phosphoric. Alkalis will attack
the surface of glass. Water born materials from
surrounding surfaces may leave deposits on
the glass. These should be removed as soon
as possible

. 

. 

21C
6.0
6.5
7.4
30.0

Knowledge

Did you know?


Viridians founding glass company
opened its first office in Australasia
in 1879.

Knowledge
Glass Processing

Glass processing
Countersunk holes at 45 angle
available on 5mm-19mm thickness

Figure 1

Maximum hole diameter to be less than


50% of narrowest height/width of glass for
holes over 75mm. Dog and cat doors
attract special rules

Most architectural glass will have


some form of edgework other than
edges that are clean-cut. The types
of edge work are summarised in the
table on page 119. In addition, there
are specialist decorative finishes
available that are primarily used
for furniture.

Minimum diameter
5mm but not less than
thickness of glass

Figure 2

Distance to be 1.5 x thickness


of glass up to 10mm glass
and 2 x thickness of glass
over 10mm for holes at sides

Figure 4

Distance between holes


to be at least 4 x thickness
of glass

Figure 3

Holes at corners distance to be 4 x thickness of glass from one edge and at least 1.5 x
thickness from other edge. Except where glass thickness >10mm to be 4 x thickness
to both edges and where angle of corner < 90 to be 4 x thickness to both edges

The guidelines for toughened safety


glass summarise key dimensions and
tolerances for holes and notches.
Please refer any applications outside
these tolerances to Viridian for review.

Figure 1

Height/width of cut-out to be
no more than 33% of height/
width of glass

Minimum radius
equals glass thickness
at end of cut-out

Figure 2

Radius of corners
to be equal to the
thickness of the glass

Minimum 19mm
radius at semi-circle
of cut-out

Figure 6

Interior width and


height of cut-out not
to be less than the
thickness of the glass

Figure 3

External corners
must be rounded

Figure 5

Distance between cut-out and


edge of glass to be at least
50% of hole/cut-out width or
height in the direction in question
Minimum of 75mm 4-6mm glass
Minimum of 100mm 8-19mm glass

viridianglass.com

Corners
Rounded

Figure 4

Rectangular cut-outs to have a


hole radius. Have radius corners
or semicircular ends not less than
the glass thickness

Knowledge
Other points

Position of cut-out from edge


The edge distance must be greater than half
ofcut-out height

. 

The edge distance must be greater than half


ofcut-out width

. 

The inside of cut-out must have radius corners


to a dimension of not less than the thickness
ofthe glass

. 

In a panel with holes, the minimum width of


the panel must be eight times the thickness
ofthe glass

. 

Glass Processing

In a panel of glass where there are a cluster


ofholes (eg. more than four), please refer to
our sales staff for advice

. 

Refer to our sales staff for advice.


Types of glass edge work

Did you know?


Heat strengthened glass is not
recognised as a Grade A safety glass.

Clean Cut
Edge

OG-CNC
Polished Edge

Polish Edge
15 Back Mitre

Polish Edge
22.5 Back Mitre

Polished Edge
Tip Corners

Polished Edge

Rough Arrised Edge

Smooth Edge

Polish Edge
45 Back Mitre

Edge working
Types of glass edge work

Detail

Application

Clean cut

As cut edges, edges are sharp

General glazing concealed edges

Rough arriss

Sharp edges are removed. Minimum


edge work for toughened glass

General glazing concealed edges

Flat grind or flat smooth

Machine smoothed edges

Silicon butt joints

Flat polish

Machine polished

Exposed edges and furniture

Mitre

Machine edge 45mm or 67.5mm

Angled silicon glazing

Bevel

Machine edge
4mm max 25mm
5mm max 30mm
6mm to 19mm max 35mm

Decorative finish for windows, furniture


and mirrors exposed edges also
require flat polishing

Knowledge
Heat Soak
Treatment

Reduce the risk of


potential breakage from
nickel sulphide inclusions
Description

Technical outline

Heat soak treatment is a quality control process

Toughened glass may potentially break from

carried out on Viridian toughened safety glass.

an impurity in the glass called nickel sulphide

It is designed to reject glass panels that may

(NiS). This type of breakage is very rare as most

potentially break due to impurities such as

breakages are the result of impact, incorrect

nickel sulphide or defective edges that are

glazing or structural movement. The heat soak

undetectable during manufacture.

treatment subjects toughened glass to elevated

Benefits
Heat soak treatment significantly reduces the

temperatures for a specific time depending on


glass thickness.

risk of breakage of installed toughened glass

The Viridian process is carefully controlled so that

from spontaneous fracture. For building owners,

the toughened glass maintains its strength.

developers and specifiers, heat soak treatment

NiS inclusions can occur in batches and therefore

offers a number of benefits.

may be more apparent in isolated projects.

Reduces potential public liability

. 

Low cost compared to glass replacement costs

. 

The heat soak treatment reduces the risk by


eliminating over 95% of the potential breakages
due to NiS inclusions.

Other considerations and alternative products


Applications
Heat soak treatment should be used
when specified in the BCA or when
toughened glass is specified in
structural applications and in locations
where safety is paramount. These
applications include:
Viridian Structural Glazed Systems
and suspended glass assemblies

. 

Balustrading

. 

Toughened glass used in spandrels

. 

Solar control glazing to high rise


buildings

. 

Overhead and sloped glazing

. 

Warranty requirement

The breakage characteristics need to be


assessed in the selection of toughened glass
(refer to page 5 selecting the right glass).
Laminated safety glass the PVB or resin
interlayer will restrict glass granules falling.

. 

Heat strengthened glass this provides


resistance to thermal breakage and can resist
greater loads than annealed glass.

. 

Its breakage characteristic means that if large


pieces are broken, they often remain in place
similar to annealed glass. It is not a safety glass
but has reduced potential breakage from
nickel sulphide inclusions due to lower stress
than toughened glass.

Comparative potential breakage

. 

Maximum size
5500 x 2500mm

. 

Annealed
float glass1

0.8%

Toughened
glass2
Heat soak
treatment
toughened
glass3

0.59%
0.321%
0% 0.5%
1.0%


Probability of NiS breakage

Potential of breakage at max load

1B
 ased on 6mm float glass. 2.0 kPa windload, max area.
Per Australian Standard AS1288 or New Zealand Standard NZS4223
2 Toughened glass has 2.5 times resistance for equal
load and thickness
3 Heat soak treatment 95% NiS conversion

viridianglass.com

Cleaning of glass

Knowledge

Instructions to all trades and individuals

Please note

About this cleaning advice

Always follow the manufacturers installation and

Viridian SmartGlass, Renew, SolTech,

This information is offered as a general


guide only and specific advice should
always be sought from a reputable
glazier or professional window cleaner
before undertaking any cleaning.
The advice does not preclude the
use of other methods, materials or
equipment, however the user should
undertake careful evaluation and make
suitable enquiries as to the suitability
of alternative methods, materials or
equipment, before using them. While
Viridian has made every effort to
ensure the accuracy and effectiveness
of this information, Viridian makes no
representation as to the accuracy
or effectiveness of the information
and takes no responsibility for any
loss, damage or injury which may be
caused as a direct or indirect result
of the use of this information.

cleaning instructions. It is recommended that

ComfortPlus, EnergyTech, EnviroShield

glass be protected from contamination caused

Reflective and EVantage require specific

by building materials and methods during

cleaning procedures. These can be found on

construction as this will greatly simplify the glass

theViridian website.

cleaning task at the end of the project. If the


glass is not protected during construction then the
glass and frames should be cleaned frequently
during construction. Construction dust, leachate
from concrete and rusting from steel can
contribute to the formation of mild chemicals.
These may stain or otherwise damage the glass.
Glass should be cleaned using only cleaning
materials which are free of grit and debris
(to avoid scratching and marking of the glass
surface). Only detergents and cleaning solutions
which are recommended for cleaning glass
should be used. Mild detergents are preferable.
Extra care is necessary where high performance
reflective glass is installed. The coated surface
can be susceptible to stains and scratches
and therefore requires vigilance during the
full construction process. Temporary screens
should be installed if welding, sandblasting, floor
sanding, cutting or other potentially damaging
construction practices take place near the glass.

Care of mirrors
Mirrors require special cleaning care. To clean
mirrors, simply wipe over the surface with a few
drops of methylated spirits on a damp cloth.
Polish surface dry with a lint free cloth. Some
proprietary glass cleaners, if used to excess, can
cause damage to the silvering as can excessive
amounts of water. Make certain when cleaning
the face of the mirror that there is no contact
with the silver backing, particularly at the edge
of the glass and be careful to keep any moisture
away from the paint backing of the mirror. Do
everything possible to ensure that the cleaning
cloths used are free of any abrasives.
If damage occurs
If glass is damaged or broken on-site, ensure
that experienced glaziers are engaged to rectify
the situation. Glass can be a safety hazard if not
handled properly.

Glass installations which are adjacent to concrete

Note to the painter

(e.g. concrete slab floors) require extra care and

Paint spots have been traditionally removed using

cleaning due to the abrasive nature of concrete

a sharp razor blade. The use of a blade can in

dust. All tradespeople should be advised to be

some cases cause damage to the glass. As an

aware of damaging glass and windows and

alternative, investigate solvents or graffiti removal

to leave in place any materials protecting the

materials, ensuring that they will not damage the

window or glass.

glass. If a blade or scraper is used then the risk


of damage can be reduced by using a scraper
which has a clean edge and is held at an angle
of 30 to the glass. Consult the supplier of the
blade or scraper as to how it is best used to clean
glass. However, surface coated, modified or
tinted glass requires special care. Seek cleaning
advice from your local glass merchant.

Knowledge

Standards and warranties


The following is an outline of key standards
relating to glass selection and performance
that are referenced throughout this guide.
The Building Codes of Australia and New Zealand
refer to Australian Standard AS1288 and New
Zealand Standard NZS4223 respectively as a
deemed to comply document. The Building
Codes provisions for energy efficient glazing
in each region impact on solar control and
thermal insulation glass selection.
Australian Standard AS1288 Glass in
buildings Selection and installation or
NewZealand Standard NZS4223 Glazing
inbuildings
Specifies procedures for the design, selection
and installation of glass in buildings. Includes
guidance for installation practice, based on
proven techniques. Design loads including
windload are selected from AS/NZS1170.0,
AS/NZS1107.2 or AS4055

. 

AS/NZS2208 Safety glazing materials


in buildings
Glass that is installed where safety glass is
required must be manufactured in accordance
with AS/NZS2208. This is the standard that safety
glazing materials are product certified to for
use in Australia and NewZealand

. 

AS/NZS4666 Insulating glass units


This standard sets out the performance
requirements and guidelines on the selection
and installation of insulating glass units

. 

AS/NZS4667 Quality requirements for cut


to size processed glass
Sets out the quality requirements for cut sizes of
flat, transparent, clear ordinary annealed, tinted
heat-absorbing, patterned and wired glass for
general glazing and/or further processing

. 

AS3555.1 Testing and rating for intruder


resistance
Intruder resistant panels Identifies the testing
and performance level for the specification
of glass against physical attack

. 

AS/NZS2343 Bullet resistant panels


and elements
Specifies the requirements for bullet resistant
panels and elements according to their
performance in preventing penetration by
projectiles discharged from firearms under
controlled conditions

. 

AS 3959 Construction of Buildings


in Bushfire Prone Areas
Specifies the minimum construction
requirements for each defined Bushfire
Attack Level (BAL)

. 

AS 1530.8.1 Tests on elements


of construction for buildings exposed
to simulated bushfire attack
The testing procedure by which glazing
materials should be measured to enable
item to be used in lieu of the relevant BAL
as outlined in AS3959. This is relevant for BAL
up to and including BAL 40

. 

AS1530.4 Methods for fire tests on building


materials, components and structures
Fire resistance tests of elements of building
construction. This Standard applies to heating
conditions, test procedures and criteria for the
determination of fire resistance of an element
of building construction. In most cases,
a single test, carried out in accordance with
this Standard establishes the fire resistance for
the element of construction concerned

. 

AS/NZS1170 Structural design actions


There are four parts which cover general
principles; permanent, imposed and other
actions; wind actions; snow and ice actions

. 

Viridian warranties
Viridian provides comprehensive warranties for
its architectural products. Our warranty is your
assurance that the selection of Viridian glass
will reduce your long term risk. Our national
distribution network means that it is easy to
contact us should there be a problem.
Warranty and CAS details are available on our
website and cover the following products:
Viridian VLam including ComfortPlus andViridian
DcorPattern glass

. 

VTough projects of over 100m2 must be


brought to our attention

. 

EVantage

. 

EnergyTech and SolTech

. 

ThermoTech

. 

Viridian Structural Glass Systems

. 

DcorMirror

. 

DcorPanel

. 

EnviroShield Reflective

. 

SmartGlass

. 

viridianglass.com

Knowledge

Energy Management
Performance Data

Insulation is the products U Value.


The lower the number the better
performance.

Performance comparison chart

These characteristics, along with colour and

To assist with selecting Viridian products we have

reflectivity, are the key performance attributes.

Solar is the solar heat gain


coefficient (SHGC). The lower the
number, the better the performance.

developed a performance comparison arranged

Additional functions such as safety, security

into three tables:

and noise attenuation can also be added

Daylight is the products visible light


transmission as a percentage.

. 

. 

. 

. 

to all glass types.

Viridian single glazing

The number in the bar is the actual performance.

Insulated Glass Unit

. 

Please note all performance data listed is

Insulated Glass Unit with EnergyTech on surface #3

. 

glass only data. For total window perfomance,

These have been divided into three catagories that

please visit www.wers.net

shows by coloured bars the products performance


in relation to:
Insulation

. 

Solar control

. 

Daylight transmission

. 

Single glazing
Product

Insulated Glass Unit with


EnergyTech on surface #3

Insulated Glass Unit

Insulation

Solar

Daylight

Insulation

Solar

Daylight

Insulation

Solar

Daylight

Viridian VFloat Grey

5.8

0.58

42

2.5

0.45

37

1.6

0.40

34

Viridian EnergyTech Clear

3.6

0.69

81

1.6

0.61

73

1.5

0.59

67

Viridian EnergyTech Grey

3.7

0.47

40

1.7

0.39

35

1.5

0.37

33

In this selection EnergyTech Clear Low E


has better insulation, with a lower U Value
than VFloat Grey.

In this selection EnergyTech Grey


has the most effective solar reduction.
With an SHGC of 0.47 when single
glazed, it eliminates the most solar heat.

Refer to performance data tables for more information and products. Nominal 6mm glass
or greater has been used. IGUs are argon gas filled with 12mm width gap.

viridianglass.com

In this selection EnergyTech Clear


has the highest visible light transmission.

Performance comparison chart


Single Glazing
Product

Insulated Glass Unit with


EnergyTech on surface #3

Insulated Glass Unit

Insulation

Solar

Daylight

Insulation

Clear

5.8

0.82

88

2.5

Bronze

5.8

0.62

49

2.5

Solar

Daylight

Insulation

Solar

Daylight

0.71

78

1.6

0.67

73

0.50

43

1.6

0.44

40

VFloat

Green

5.8

0.61

77

2.5

0.50

68

1.6

0.45

63

Grey

5.8

0.58

42

2.5

0.45

37

1.6

0.40

34

SuperGreen

5.8

0.52

67

2.5

0.39

59

1.6

0.35

55

SuperBlue

5.8

0.52

53

2.5

0.39

47

1.6

0.34

43

SuperGrey

5.8

0.35

2.5

0.21

1.6

0.15

57

High Performance Tones

EVantage
Clear

3.8

0.63

68

1.7

0.56

61

1.5

0.53

BlueGreen

3.8

0.45

56

1.7

0.38

51

1.5

0.36

47

Bronze

3.8

0.45

38

1.7

0.38

34

1.5

0.35

32

Grey

3.8

0.41

32

1.7

0.33

29

1.5

0.31

27

SuperGreen

3.8

0.37

49

1.7

0.30

44

1.5

0.27

41

SuperBlue

3.8

0.36

39

1.7

0.29

35

1.5

0.27

33

EnergyTech & SolTech


EnergyTech Clear

3.6

0.69

81

1.6

0.61

73

1.5

0.59

67

SolTech Neutral

3.7

0.53

63

1.6

0.45

56

1.5

0.43

52

EnergyTech Green

3.7

0.49

71

1.6

0.41

63

1.5

0.39

59

EnergyTech Grey

3.7

0.47

40

1.7

0.39

35

1.5

0.37

33

EnergyTech SuperGreen

3.7

0.40

61

1.6

0.32

54

1.5

0.31

50

SolTech Grey

3.7

0.36

30

1.6

0.28

27

1.5

0.27

25

68

ComfortPlus
Clear 82

3.6

0.68

82

1.6

0.60

73

1.5

0.58

Translucent

3.6

0.56

62

Neutral 59

3.6

0.51

59

1.6

0.42

53

1.5

0.40

49

Grey 40

3.6

0.50

39

Green 71

3.6

0.50

71

Grey 37

3.6

0.39

37

1.6

0.31

33

1.5

0.30

31

SuperGreen 49

3.6

0.36

49

1.6

0.29

44

1.5

0.27

40

SuperBlue 44

3.6

0.33

35

1.6

0.25

31

1.5

0.23

29

ITO Clear 74

3.6

0.54

75

1.6

0.46

67

1.5

0.44

62

ITO Green 67

3.6

0.45

69

1.6

0.38

61

1.5

0.36

57

ITO Neutral 54

3.6

0.44

56

1.6

0.36

50

1.5

0.34

46

ITO Grey 33

3.6

0.35

35

1.6

0.27

31

1.5

0.25

29

ITO SuperGreen 45

3.6

0.34

46

1.6

0.26

41

1.5

0.25

38

ITO SuperBlue 40

3.6

0.31

34

1.6

0.23

30

1.5

0.21

28

XIR Clear 71

5.7

0.50

73

XIR Clear 70

5.5

0.50

71

XIR EnergyTech 62 (#4)

3.5

0.41

65

PerformaTech Clear 206 (#2) with VFloat Clear

1.3

0.33

59

PerformaTech Silver 236 (#2) with VFloat Clear

1.3

0.25

59

PerformaTech Silver 196 (#2) with VFloat Clear

1.3

0.30

59

EnviroShield Performance

PerformaTech

The bar chart diagram is for indication only, for performance data please refer to the glass performance data tables
at the end of this document.

Explanation of performance data tables


The following chart is an extract from the performance data table. The information is for the standard stock items in the
Viridian Australia range. Not all manufactured or custom options have been included.

Visible

Solar

Product Name

Nominal
Thickness

Trans.

Refl. Out

Refl. In

Trans.

Refl.

SuperBlue

6+12+6

47

13

27

17

1 
Product name refer to product for more information.
Where (#2) appears, this identifies the glass coated
surface that is glazed to the inside of a building or the
inside of a ThermoTech unit.
2 Nominal thickness the glass thickness or the makeup
of a ThermoTech unit. The first number is the outer glass
thickness, +12mm gap, then the thickness of the inner
panel of the unit. Thickness tolerances are:
3-6mm (0.2mm)
8-12mm (0.3mm)
15mm (0.5mm)
19mm (1.0mm)
3 Visible light transmission percentage of visible light
passing directly through the glass. The wave length
range for visible light is 380 to 780nm. The higher the
percentage the more daylight.
4 Visible light reflection percentage of visible light
reflected toward the exterior.
5 Solar transmission percentage of normally incident
visible light and solar energy passing directly through
the glazing. The wave lengths measured for solar
energy is 300 to 2500nm.

UV Trans.

U Value
Air

Argon

2.7

2.5

0.46

10

6 Solar reflection percentage of normally incident visible


light and solar energy reflected toward the exterior.
7 UV transmission the percentage of UV light
transmitted measured in the light range of
300380nm. The lower the number the better.
8 U Value measurement unit is watts per m2 per degree
celcius (W/m2C) and is a measure of the rate of heat
gain or loss through glazing due to environmental
differences between outdoor and indoor air.*
9 SHGC (Solar Heat Gain Coefficient) the proportion
of total solar radiation that is transferred through the
glass at normal incidence. It comprises the direct solar
transmission (5) and the part of the solar absorption
dissipated inwards by radiation and convection. The
lower the number the better the solar performance.*
10 Shading coefficient the ratio of solar heat gain
through the glass relative to that through 3mm
clear glass. The lower the number the better
the performance.

Shading Co. Weight m2

0.39

*The published U Value is based on Glasss Only and cannot be used for BCA Section J calculations where the total U Value is required.

viridianglass.com

SHGC

30

Note Data is based


on laboratory
spectrophotometric
measurements and
reduced using Windows
software for AFRC 1002001
conditions, which is the
internationally recognised
method for describing
glass performance.
The data is glass only
and care should be
exercised when evaluating
manufacturers published
data that the same
environmental conditions
have been used.

Viridian single glazing


Product Name

Visible

Solar

Nominal
Thickness

Trans.

Refl. Out

Refl. In

Trans.

Refl.

3
4
5
6
8
10
12
15
19
4
5
6
12
10
4
10
5
6
4
5
10
12
6

89
89
88
88
86
85
84
87
86
56
47
42
21
26
82
63
80
76
61
54
34
26
51

8
8
8
8
8
8
8
8
8
6
6
5
4
4
8
6
8
8
7
6
5
5
5

8
8
8
8
8
8
8
8
8
6
6
5
4
4
8
6
8
8
7
6
5
5
5

83
82
79
78
71
67
64
76
72
55
47
42
25
28
58
29
55
47
60
52
36
28
52

87
86
87
87
86
85
42
41
41
41
52
52
51
51
71
71
70
69
72
71
70
70
66
66
64
64
79
79
77
77
65
64
65
32

8
8
8
8
8
8
5
5
5
5
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
6
8
8
7
7
6
6
6
5

8
8
8
8
8
8
5
5
5
5
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
6
8
8
7
7
6
6
6
5

92
91
90
90
90

8
8
8
8
8

73
70
67
77
9
53
41

7
7
6
7
4
6
5

UV Trans

U Value

SHGC

Shading Co. Weight m2

8
8
7
7
7
7
7
7
7
6
5
5
5
4
6
5
6
6
6
6
5
4
5

69
67
63
60
56
52
48
59
54
30
23
19
9
10
36
11
33
30
28
22
9
6
19

5.9
5.9
5.9
5.8
5.7
5.7
5.7
5.5
5.4
5.9
5.8
5.8
5.6
5.7
5.9
5.7
5.9
5.8
5.9
5.9
5.7
5.6
5.8

0.85
0.83
0.83
0.82
0.77
0.75
0.72
0.81
0.79
0.66
0.61
0.58
0.47
0.50
0.68
0.49
0.67
0.62
0.70
0.64
0.54
0.49
0.65

0.98
0.98
0.95
0.95
0.89
0.86
0.84
0.93
0.91
0.77
0.71
0.67
0.55
0.57
0.79
0.57
0.77
0.71
0.81
0.74
0.63
0.57
0.75

7.5
10
12.5
15
20
25
30
37.5
47.5
10
12.5
15
30
25
10
25
12.5
15
10
12.5
25
30
15

72
71
69
72
66
65
47
46
42
41
51
50
46
45
63
62
57
56
63
62
57
56
56
55
51
50
63
62
57
56
31
30
31
36

7
7
7
7
7
7
6
5
5
5
6
6
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
5
5
5
5

<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1

5.7
5.7
5.6
5.7
5.6
5.6
5.7
5.7
5.6
5.6
5.7
5.7
5.7
5.6
5.7
5.7
5.6
5.6
5.7
5.7
5.6
5.6
5.7
5.7
5.6
5.6
5.7
5.7
5.6
5.6
5.6
5.6
5.75
5.7

0.78
0.78
0.76
0.78
0.74
0.74
0.61
0.61
0.59
0.58
0.64
0.64
0.61
0.61
0.72
0.72
0.69
0.68
0.72
0.72
0.68
0.68
0.67
0.67
0.64
0.64
0.72
0.72
0.69
0.68
0.51
0.51
0.51
0.54

0.90
0.90
0.88
0.90
0.85
0.85
0.71
0.71
0.67
0.67
0.74
0.74
0.70
0.70
0.83
0.83
0.79
0.78
0.83
0.82
0.78
0.78
0.78
0.77
0.74
0.73
0.83
0.83
0.79
0.78
0.59
0.58
0.59
0.63

15.4
15.8
16.6
20.4
25.4
30.4
15.4
20.4
25.4
30.4
15.4
20.4
25.4
30.4
15.4
20.4
25.4
30.4
15.4
20.4
25.4
30.4
15.4
20.4
25.4
30.4
15.4
20.4
25.4
30.4
25.4
30.4
15.4
15.8

8
8
8
8
8

91
89
87
86
85

8
8
8
8
7

86
84
81
79
77

5.8
5.8
5.7
5.6
5.4

0.90
0.90
0.89
0.88
0.87

1.04
1.03
1.02
1.01
1.00

10
15
25
30
37.5

7
7
6
7
4
6
5

42
38
34
50
8
33
22

5
5
5
6
4
5
5

22
18
13
28
1
20
13

5.9
5.8
5.8
5.9
5.8
5.8
5.7

0.58
0.55
0.52
0.64
0.35
0.52
0.44

0.67
0.64
0.61
0.73
0.41
0.60
0.52

10
12.5
15
7.5
15
15
25

Viridian VFloat

Clear

Clear N

Grey
Grey N
Green
Green N

Bronze
Bronze N
Viridian VLam

6.38
6.76
7.52
Clear
8.38
10.38
12.38
6.38
8.38
Grey
10.38
12.38
6.38
8.38
Bronze
10.38
12.38
6.38
8.38
Green
10.38
12.38
6.38
8.38
Cool Blue
10.38
12.38
6.38
8.38
Translucent
10.38
12.38
6.38
8.38
Soft White
10.38
12.38
10.38
SuperGreen
12.38
SuperGreen N
6.38
Translucent Grey
6.76
Viridian VFloat SuperClear TC
4
6
VFloat SuperClear
10
12
15
Viridian High Performance Tones
4
SuperGreen
5
6
SuperGreen N
3
SuperGrey
6
6
SuperBlue
10

Viridian single glazing


Nominal
Thickness

Trans.

Visible
Refl. Out

Refl. In

Trans.

Refl.

6
6
6
6
6
6

32
38
56
68
49
39

10
11
19
23
16
12

27
27
27
26
27
27

29
35
35
59
24
23

4
6
4
6
4
6

83
81
61
63
50
40

11
11
8
9
7
6

11
12
10
10
9
9

3
4
5
6
10
4
6
4
6
4
6

83
83
82
81
80
75
71
68
61
50
40

11
11
11
11
10
10
9
9
8
7
6

3
4
6
10
6

62
61
63
60
30

6.38
8.38
10.38
12.38
6.38
8.38
10.38
12.38
10.38
12.38
6.38
6.38
8.38
10.38
12.38
8.38
10.38
12.38
8.38
10.38
12.38
10.38
12.38
6.38
10.38

Viridian ComfortHush
Clear (#4)
Neutral (#4)
Viridian VLam Hush
Clear

Product Name
Viridian EVantage
Grey (#2)
Bronze (#2)
BlueGreen (#2)
Clear (#2)
SuperGreen (#2)
SuperBlue (#2)
Viridian SmartGlass
SP10 Clear Polaris (#2)
SP30 Neutral Panoramic (#2)
SP35 Grey Dusk (#2)

Solar

UV Trans

U Value

SHGC

Shading Co. Weight m2

8
10
11
17
9
8

10
11
16
30
8
10

3.8
3.8
3.8
3.8
3.8
3.8

0.41
0.45
0.45
0.63
0.37
0.36

0.48
0.53
0.53
0.73
0.43
0.43

15
15
15
15
15
15

68
65
46
45
45
37

11
10
8
8
7
7

54
48
44
41
21
16

3.7
3.6
3.7
3.7
3.7
3.7

0.72
0.69
0.53
0.53
0.53
0.47

0.83
0.80
0.62
0.62
0.62
0.55

10
15
10
15
10
15

11
11
12
12
11
11
10
10
10
9
9

71
68
67
65
59
49
39
37
28
45
37

11
11
11
10
9
8
7
7
6
7
7

58
54
52
48
42
30
23
18
12
21
16

3.7
3.7
3.7
3.6
3.6
3.7
3.7
3.7
3.7
3.7
3.7

0.73
0.72
0.70
0.69
0.65
0.56
0.49
0.47
0.40
0.53
0.47

0.85
0.83
0.81
0.80
0.75
0.65
0.57
0.54
0.47
0.62
0.55

7.5
10
12.5
15
25
10
15
10
15
10
15

8
8
9
8
5

10
10
10
9
8

47
46
45
40
23

8
8
8
7
6

47
44
41
38
13

3.7
3.7
3.7
3.6
3.7

0.55
0.53
0.53
0.50
0.36

0.64
0.62
0.62
0.58
0.42

7.5
10
15
25
15

59
60
62
61
39
39
38
38
65
59
70
82
80
79
79
37
38
29
49
50
46
35
36
62
60

7
8
8
8
6
6
6
6
8
8
9
10
11
11
10
6
6
5
7
7
7
6
6
8
8

9
10
10
10
9
9
9
9
10
10
10
11
11
11
11
9
8
8
9
9
9
9
8
10
10

42
41
40
39
40
38
36
34
32
26
39
64
60
58
55
27
26
20
23
23
19
18
18
48
44

7
7
7
7
7
7
6
6
6
5
7
9
9
9
8
6
6
5
5
5
5
5
5
7
7

<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1

3.6
3.6
3.6
3.5
3.6
3.6
3.6
3.5
3.6
3.5
3.64
3.6
3.6
3.6
3.5
3.6
3.6
3.5
3.6
3.6
3.5
3.6
3.6
3.6
3.6

0.51
0.50
0.49
0.49
0.50
0.48
0.47
0.45
0.43
0.39
0.50
0.68
0.66
0.64
0.62
0.39
0.39
0.34
0.36
0.37
0.34
0.33
0.33
0.56
0.53

0.60
0.58
0.58
0.57
0.58
0.56
0.54
0.53
0.51
0.46
0.57
0.79
0.76
0.74
0.72
0.46
0.46
0.40
0.43
0.43
0.40
0.38
0.39
0.65
0.62

15.4
20.4
25.4
30.4
15.4
20.4
25.4
30.4
25.4
30.4
15.4
15.4
20.4
25.4
30.4
20.4
25.4
30.4
20.4
25.4
30.4
25.4
30.4
15.4
25.4

6.5
6.5

82
59

10
7

11
9

64
42

9
7

<1
<1

3.6
3.6

0.68
0.51

0.79
0.60

15.5
15.5

6.5
8.5
10.5
12.5

87
87
87
87

8
8
8
8

8
8
8
8

72
72
70
69

7
7
7
7

<1
<1
<1
<1

5.7
5.7
5.6
5.5

0.78
0.78
0.77
0.76

0.90
0.90
0.89
0.88

15.5
20.5
25.5
30.5

8.76
10.76
12.76
8.76
10.76
12.76

75
74
73
69
68
64

10
10
10
9
9
8

11
11
11
10
11
10

45
44
42
34
33
28

7
7
7
6
6
6

<1
<1
<1
<1
<1
<1

3.6
3.5
3.5
3.6
3.5
3.5

0.54
0.53
0.51
0.45
0.44
0.41

0.63
0.61
0.60
0.53
0.52
0.48

20.8
25.8
30.8
20.8
25.8
30.8

Viridian EnergyTech
EnergyTech Clear (#2)
EnergyTech Clear N (#2)
EnergyTech Green (#2)
EnergyTech SuperGreen (#2)
EnergyTech Grey (#2)
Viridian SolTech
SolTech Neutral (#2)

SolTech Grey (#2)


Viridian ComfortPlus
Neutral 59 (#4)

Grey 40 (#4)

Green 71 (#4)
Green 71 N (#4)
Clear 82 (#4)

Grey 37 (#4)

SuperGreen 49 (#4)
SuperBlue 44 (#4)
Translucent (#4)

Enviroshield Performance
ITO Clear 74 (#4)

ITO Green 67 (#4)

viridianglass.com

Viridian single glazing


Product Name

Nominal
Thickness

Trans.

Visible
Refl. Out

Refl. In

Trans.

Solar
Refl.

8.76
10.76
12.76
8.76
10.76
12.76
8.76
10.76
12.76
12.76
6.76
12.76
12.76

56
58
57
35
36
27
46
47
43
34
73
71
65

8
8
8
6
6
5
7
7
6
6
7
7
9

10
9
9
9
8
8
9
9
9
8
7
7
10

32
32
31
21
21
16
19
20
17
15
39
37
32

6.38
6.38
6.38
6.38
7.38

79
38
48
64
64

18
15
13
17
17

17
7
8
9
13

6.38
12.38

92
90

1.7
1.6

1.7
1.6

UV Trans

U Value

SHGC

Shading Co. Weight m2

6
6
6
5
5
5
5
5
5
5
23
21
21

<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1

3.6
3.5
3.5
3.6
3.5
3.5
3.6
3.5
3.5
3.6
5.7
5.5
3.5

0.44
0.44
0.43
0.35
0.35
0.31
0.34
0.34
0.33
0.31
0.50
0.50
0.41

0.51
0.51
0.50
0.41
0.41
0.37
0.40
0.40
0.38
0.36
0.58
0.58
0.48

20.8
25.8
30.8
20.8
25.8
30.8
20.8
25.8
30.8
30.8
15.8
30.8
30.8

69
45
48
60
35

14
12
11
13
12

<1
<1
<1
<1
<1

5.8
5.7
5.7
5.8
5.7

0.74
0.58
0.60
0.68
0.51

0.85
0.67
0.70
0.78
0.59

15.4
15.4
15.4
15.4
17.9

70
63

3
3

<1
<1

4.6
4.4

0.77
0.72

0.89
0.83

15.4
30.4

Enviroshield Performance
ITO Neutral 54 (#4)

ITO Grey 33 (#4)

ITO SuperGreen 45 (#4)


ITO SuperBlue 40 (#4)
XIR Clear 71
XIR Clear 70
XIR EnergyTech 62 (#4)
Renew Laminates
Clear (#1)
Grey (#1)
Bronze (#1)
Green (#1)
SuperGreen (#1)
OptiView Laminate
OptiView

Typical measured values of Viridian production are provided. All performance data is determined using LBL Windows 5.2 software, NFRC 100-2001
conditions have been used. Product Name Where # appears, ie (#2), this identifies the position of the coated surface of the glass. Glass surfaces
are counted from the exterior to the interior of the building. Nominal Thickness The glass thickness or the makeup of a Viridian ThermoTech unit.
The first number is the outer glass thickness, +12 Air is the width of the airspace, then the thickness of the inner panel of the unit. Thickness tolerances
are: 3-6mm (0.2mm); 8-12mm (0.3mm); 15mm (0.5mm); 19mm (1.0mm).

Viridian ThermoTech insulating glass units


Product Name

Visible

Solar

Nominal
Thickness

Trans.

Refl. Out

Refl. In

Trans.

Refl.

3+12+3
4+12+4
5+12+5
6+12+6
8+12+6
10+12+6
12+12+6
4+12+4
5+12+5
6+12+6
10+12+6
12+12+6
4+12+4
5+12+5
6+12+6
10+12+6
4+12+4
5+12+5
6+12+6
10+12+6

81
80
79
78
77
76
75
50
42
37
24
19
73
70
68
56
55
48
43
30

15
15
15
15
14
14
14
8
7
7
5
5
13
13
12
9
10
8
8
6

15
15
15
15
14
14
14
13
12
12
12
12
14
14
13
13
13
13
12
12

69
69
63
62
57
54
51
46
38
33
24
20
49
42
39
24
50
41
38
28

13
13
12
12
11
10
10
8
7
7
5
5
9
9
8
6
9
7
7
6

6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.76+12+6

78
37
46
63
64
58
70
57
28

15
7
8
11
11
10
13
10
6

15
12
13
14
14
13
14
13
12

58
37
40
50
50
44
50
26
28

4+12+4
5+12+5
6+12+6
6+12+6
6+12+6
10+12+6

65
63
59
8
47
36

11
11
10
4
8
7

14
13
13
11
13
12

6+12+6
6+12+6
6+12+6
6+12+6
6+12+6
6+12+6

29
34
51
61
44
35

10
13
21
27
18
13

4+12+4
6+12+6
10+12+6
4+12+4
6+12+6
4+12+4
6+12+6
4+12+4
6+12+6

75
73
71
68
63
61
54
45
35

4+12+4
6+12+6
6+12+6

55
56
27

U Value

SHGC

Shading
Co.

Weight
m2

2.6
2.6
2.5
2.5
2.5
2.5
2.5
2.6
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

0.75
0.75
0.72
0.71
0.66
0.64
0.61
0.55
0.49
0.45
0.38
0.34
0.57
0.52
0.50
0.37
0.59
0.52
0.50
0.41

0.87
0.86
0.83
0.82
0.76
0.73
0.71
0.64
0.57
0.52
0.44
0.40
0.66
0.60
0.57
0.43
0.68
0.61
0.57
0.48

15
20
25
30
35
40
45
20
25
30
40
45
20
25
30
40
20
25
30
40

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

0.67
0.49
0.52
0.60
0.60
0.55
0.61
0.38
0.41

0.77
0.56
0.60
0.70
0.69
0.64
0.70
0.44
0.48

30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.8

18
15
10
1
17
10

2.7
2.7
2.7
2.7
2.7
2.6

2.6
2.5
2.5
2.5
2.5
2.5

0.46
0.43
0.39
0.21
0.39
0.31

0.54
0.50
0.46
0.25
0.46
0.36

20
25
30
30
30
40

9
11
12
20
9
9

8
9
13
23
7
8

2.0
2.0
2.0
2.0
2.0
1.9

1.7
1.7
1.7
1.7
1.7
1.7

0.33
0.38
0.38
0.56
0.30
0.29

0.39
0.44
0.44
0.64
0.34
0.33

30
30
30
30
30
30

57
52
48
41
33
32
24
38
29

15
14
12
10
9
8
7
9
8

41
36
32
25
19
15
10
18
13

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.7
1.6
1.6
1.6
1.6
1.7

0.64
0.61
0.58
0.49
0.41
0.39
0.32
0.46
0.39

0.74
0.71
0.66
0.56
0.48
0.45
0.37
0.53
0.45

20
30
40
20
30
20
30
20
30

38
36
19

10
10
6

34
30
10

1.9
1.9
1.9

1.6
1.6
1.6

0.46
0.45
0.28

0.53
0.52
0.33

20
30
30

UV Trans.

Air

Argon

53
51
47
44
42
39
37
24
19
15
9
7
30
25
21
9
23
18
15
7

2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.7
2.7
2.7
2.7
2.6
2.7
2.7
2.7
2.6
2.7
2.7
2.7
2.6

12
7
8
9
9
8
10
7
6

<1
<1
<1
<1
<1
<1
<1
<1
<1

36
32
28
6
27
17

7
7
6
4
6
5

30
29
30
29
30
30

24
28
29
47
21
19

17
16
16
15
13
13
11
9
8

18
17
17
17
16
17
16
15
16

12
12
6

16
16
12

Viridian VFloat

Clear

Grey

Green

Bronze
Viridian VLam
Clear
Grey
Bronze
Green
Cool Blue
Translucent
Soft White
SuperGreen
Translucent Grey
Viridian High Performance Tones
SuperGreen
VFloat Supergrey
SuperBlue
Viridian EVantage
Grey (#2)
Bronze (#2)
BlueGreen (#2)
Clear (#2)
SuperGreen (#2)
SuperBlue (#2)
Viridian EnergyTech
EnergyTech Clear (#2)
EnergyTech Green (#2)
EnergyTech SuperGreen (#2)
EnergyTech Grey (#2)
Viridian SolTech
SolTech Neutral (#2)
SolTech Grey (#2)

viridianglass.com

Viridian ThermoTech insulating glass units


Product Name

Nominal
Thickness

Viridian ComfortPlus
Clear 82 (#4)
6.38+12+6
Clear 82 (#4)
8.38+12+6
Clear 82 (#4)
10.38+12+6
Clear 82 (#4)
12.38+12+6
Neutral 59 (#4)
8.38+12+6
Grey 37 (#4)
8.38+12+6
SuperGreen 49 (#4)
8.38+12+6
SuperBlue 44 (#4)
10.38+12+6
Viridian ComfortHush
Clear (#4)
6.5+12+6
Neutral (#4)
6.5+12+6
Viridian EnviroShield Performance
ITO Clear 74 (#4)
8.76+12+6
ITO Green 67 (#4)
8.76+12+6
ITO Neutral 54 (#4)
8.76+12+6
ITO Grey 33 (#4)
8.76+12+6
ITO SuperGreen 45 (#4)
8.76+12+6
ITO SuperBlue 40 (#4)
12.76+12+6
Viridian Renew Laminates
Clear (#1)
6.38+12+6
Grey (#1)
6.38+12+6
Bronze (#1)
6.38+12+6
Green (#1)
6.38+12+6
SuperGreen (#1)
7.38+12+6

Visible

Solar

Trans.

Refl. Out

Refl. In

Trans.

Refl.

73
72
71
70
53
33
44
31

16
16
16
16
11
7
9
7

17
17
17
17
16
15
15
15

51
49
47
45
33
22
20
15

12
12
12
11
9
6
6
5

73
53

16
11

17
16

51
33

67
61
50
31
41
30

15
13
10
7
8
7

17
16
16
15
15
15

70
33
43
57
57

23
17
15
20
20

22
14
14
19
18

U Value

SHGC

Shading
Co.

Weight
m2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

0.60
0.58
0.56
0.54
0.42
0.31
0.29
0.25

0.69
0.67
0.64
0.62
0.49
0.36
0.33
0.29

30.4
35.4
40.4
45.4
35.4
35.4
35.4
40.4

1.9
1.9

1.6
1.6

0.60
0.42

0.69
0.49

30.5
30.5

<1
<1
<1
<1
<1
<1

1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6

0.46
0.38
0.36
0.27
0.26
0.23

0.53
0.43
0.41
0.31
0.30
0.27

35.8
35.8
35.8
35.8
35.8
45.8

<1
<1
<1
<1
<1

2.7
2.7
2.7
2.7
2.7

2.5
2.5
2.5
2.5
2.5

0.63
0.46
0.49
0.57
0.40

0.73
0.54
0.56
0.66
0.47

30.4
30.4
30.4
30.4
32.9

UV Trans.

Air

Argon

<1
<1
<1
<1
<1
<1
<1
<1

1.9
1.9
1.8
1.8
1.9
1.9
1.9
1.9

12
9

<1
<1

37
29
26
17
17
13

9
8
7
5
5
5

55
35
37
47
29

17
14
12
16
13

Notes Viridian VFloat Clear float has been used as the backing (inside) glass of the IGU. Typical measured values of Viridian production are provided.
All performance data is determined using LBL Windows 5.2 software, NFRC 100-2001 conditions have been used. Product Name Where # appears,
ie (#2), this identifies the position of the coated surface of the glass. Glass surfaces are counted from the exterior to the interior of the building.
Nominal Thickness The glass thickness or the makeup of a Viridian ThermoTech unit. The first number is the outer glass thickness, +12 is the width
of the gap, then the thickness of the inner panel of the unit. Thickness tolerances are: 3-6mm (0.2mm); 8-12mm (0.3mm); 15mm (0.5mm);
19mm (1.0mm).

Viridian PerformaTechinsulating glass units


Visible

Nominal
Thickness

Outside Glass

Inside Glass

6 + 12 + 6
6 + 12 + 6
6 + 12 + 6
6 + 12 + 6
6 + 12 + 6
6 + 12 + 6
6 + 12 + 6
6 + 12 + 6

PerformaTech Clear 206 (#2)


PerformaTech Silver 196 (#2)
PerformaTech Silver 236 (#2)
VFloat Grey
VFloat Green
VFloat SuperGreen
VFloat SuperBlue
VFloat Bronze

VFloat Clear
VFloat Clear
VFloat Clear
PerformaTech Clear 206 (#3)
PerformaTech Clear 206 (#3)
PerformaTech Clear 206 (#3)
PerformaTech Clear 206 (#3)
PerformaTech Clear 206 (#3)

Solar

Trans. Refl. Out Refl. In Trans.


68
13
15
29
59
16
17
25
59
14
18
21
32
7
11
15
59
12
12
23
52
10
12
19
41
8
12
16
38
8
11
17

Refl.
38
32
42
14
12
8
8
17

UV
Trans.
22
25
20
8
11
5
8
7

U Value
Air
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

Argon
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

SHGC
0.33
0.30
0.25
0.25
0.33
0.28
0.26
0.27

Shading Weight
Co.
m2
0.38
0.34
0.28
0.28
0.38
0.32
0.30
0.31

30
30
30
30
30
30
30
30

PerformaTech performance varies significantly with the surface on which PerformaTech is glazed. Typically in clear glazing applications,
the coating will be put on surface #2, however when combined with low SHGC glass, for example VFloat Grey, it may be preferable to glaze
to surface #3. NOTE PerformaTech will have different colour appearance depending on whether the coating is glazed to surface #2
or #3. Please consult with your Viridian representative for advice specific to your application or project.

Viridian LightBridgeinsulating glass units


Glass Product
Viridian VFloat
LightBridgeTM Clear
LightBridgeTM Grey
LightBridgeTM DecorSatin
LightBridgeTM DecorSatin Grey
LightBridgeTM Clear + S1
LightBridgeTM Grey + S1
LightBridgeTM Translucent + S1
LightBridgeTM Translucent Grey + S1
LightBridgeTM Clear + S2
LightBridgeTM Grey + S2

Visible

Solar

Nominal
Thickness

Trans.

Refl. Out

Refl. In

Trans.

Refl.

4+12+4
4+12+4
4+12+4
4+12+4
6.38+12+4
6.38+12+4
6.38+12+4
7.38+12+4
6.5+12+4
7.5+12+4

79
49
79
49
78
37
59
37
77
48

12
7
12
7
12
6
9
6
12
7

12
10
12
10
12
10
11
10
12
11

50
33
50
33
46
27
35
24
45
30

28
15
28
15
21
14
15
10
19
12

UV Trans.
37
18
37
18
0
0
0
0
0
0

U Value
Air

Argon

1.68
1.68
1.68
1.68
1.65
1.65
1.65
1.65
1.64
1.64

1.37
1.37
1.37
1.37
1.36
1.36
1.36
1.36
1.35
1.36

SHGC

Shading
Co.

Weight
m2

0.58
0.40
0.58
0.40
0.53
0.34
0.43
0.32
0.53
0.43

0.67
0.46
0.67
0.46
0.61
0.39
0.49
0.36
0.61
0.37

20
20
20
20
25.4
25.4
25.4
17.6
25.5
28

NOTE The LightBridge range and the performance values shown above are for glazing with coating to surface #3 only.

Typical measured values of Viridian production are provided. All performance data is determined using LBL Windows 5.2 software, NFRC 100-2001
conditions have been used. Outside glass Outside glass of IGU, where # appears, ie (#2), this identifies the position of the coated surface of the
glass. Glass surfaces are counted from the exterior to the interior of the building. Inside glass Inside glass of IGU, where # appears, ie (#3), this
identifies the position of the coated surface of the glass. Glass surfaces are counted from the exterior to the interior of the building. Nominal Thickness
The glass thickness or the makeup of a Viridian ThermoTech unit. The first number is the outer glass thickness, +12 is the width of the gap, then the
thickness of the inner panel of the unit. Thickness tolerances are: 3-6mm (0.2mm); 8-12mm (0.3mm); 15mm (0.5mm); 19mm (1.0mm).

viridianglass.com

Viridian ThermoTech insulating glass units with Low E


Glass Product

Visible

Solar

Nominal
Thickness

Trans.

Refl. Out

Refl. In

Trans.

Refl.

3+12+4
4+12+4
5+12+4
6+12+6
8+12+6
10+12+6
12+12+6
4+12+4
5+12+4
6+12+6
10+12+6
12+12+6
4+12+4
5+12+4
6+12+6
10+12+6
4+12+4
5+12+4
6+12+6
10+12+6

75
74
74
73
71
70
69
46
39
34
22
17
68
66
63
52
51
45
40
28

18
18
17
17
17
17
16
9
8
7
5
5
15
15
14
11
11
9
8
6

17
17
17
16
16
16
16
15
14
14
14
14
16
16
15
15
15
15
15
14

58
57
55
52
48
46
44
38
32
27
20
16
41
37
33
21
41
35
31
19

16
16
15
15
13
13
12
10
9
8
6
6
11
10
9
7
11
9
9
7

6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.38+12+6
6.76+12+6

72
34
43
59
59
55
65
53
26

17
7
9
13
13
12
15
12
6

16
14
15
16
16
15
16
15
14

50
30
34
42
42
38
43
22
23

4+12+4
5+12+4
6+12+6
6+12+6
6+12+6
10+12+6

61
59
55
7
43
34

13
12
12
4
9
7

15
15
15
13
15
14

6+12+6
6+12+6
6+12+6
6+12+6
6+12+6
6+12+6

27
32
47
57
41
33

11
13
22
29
19
14

29
29
28
28
29
29

U Value

SHGC

Shading
Co.

Weight
m2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

0.70
0.70
0.68
0.67
0.62
0.59
0.57
0.50
0.44
0.40
0.32
0.28
0.52
0.47
0.45
0.32
0.54
0.47
0.44
0.36

0.81
0.81
0.78
0.77
0.71
0.68
0.65
0.57
0.51
0.46
0.37
0.33
0.60
0.54
0.51
0.36
0.62
0.55
0.51
0.42

17.5
20
22.5
30
35
40
45
20
22.5
30
40
45
20
22.5
30
40
20
22.5
30
40

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

0.63
0.44
0.47
0.56
0.56
0.51
0.57
0.32
0.37

0.73
0.51
0.55
0.65
0.64
0.59
0.65
0.38
0.42

30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.8

15
12
8
1
13
8

1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6

0.41
0.38
0.35
0.15
0.34
0.26

0.47
0.44
0.40
0.18
0.39
0.30

20
22.5
30
30
30
40

7
7
10
19
5
7

1.8
1.8
1.8
1.8
1.8
1.8

1.5
1.5
1.5
1.5
1.5
1.5

0.31
0.35
0.36
0.53
0.27
0.27

0.36
0.41
0.41
0.61
0.32
0.31

30
30
30
30
30
30

UV Trans.

Air

Argon

42
41
40
35
34
32
30
20
16
12
7
6
24
21
17
7
19
15
12
6

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

13
8
9
11
11
10
11
7
7

<1
<1
<1
<1
<1
<1
<1
<1
<1

31
28
24
5
23
16

8
8
7
4
7
6

20
24
26
41
18
17

9
11
13
21
10
9

Viridian VFloat

Clear

Grey

Green

Bronze
Viridian VLam
Clear
Grey
Bronze
Green
Cool Blue
Translucent
Soft White
SuperGreen
Translucent Grey
Viridian High Performance Tones
SuperGreen
VFloat Supergrey
SuperBlue
Viridian EVantage Reflective
Grey (#2)
Bronze (#2)
BlueGreen (#2)
Clear (#2)
SuperGreen (#2)
SuperBlue (#2)

Viridian ThermoTech insulating glass units with Low E


Glass Product
Viridian EnergyTech
EnergyTech Clear (#2)
EnergyTech Green (#2)
EnergyTech SuperGreen (#2)
Viridian SolTech
SolTech Neutral (#2)

Visible

Solar

Nominal
Thickness

Trans.

Refl. Out

Refl. In

Trans.

Refl.

4+12+4
6+12+6
10+12+6
4+12+4
6+12+6
4+12+4
6+12+6

69
67
65
63
59
57
50

19
19
18
17
15
14
13

19
19
19
18
18
18
18

51
47
43
37
29
28
22

16
15
13
11
9
9
8

4+12+4
6+12+6
6+12+6

51
52
25

13
13
6

18
17
16

34
32
17

67
66
65
49
31
40
29

18
18
18
13
7
10
7

18
18
18
17
17
17
17

68
49

18
13

62
57
46
29
38
28
65
31
39
53
53

SolTech Grey (#2)


Viridian ComfortPlus
Clear 82 (#4)
8.38+12+6
Clear 82 (#4)
10.38+12+6
Clear 82 (#4)
12.38+12+6
Neutral 59 (#4)
8.38+12+6
Grey 37 (#4)
8.38+12+6
SuperGreen 49 (#4)
8.38+12+6
SuperBlue 44 (#4)
10.38+12+6
Viridian ComfortHush
Clear (#4)
6.5+12+6
Neutral (#4)
6.5+12+6
Viridian EnviroShield Performance
ITO Clear 74 (#4)
8.76+12+6
ITO Green 67 (#4)
8.76+12+6
ITO Neutral 54 (#4)
8.76+12+6
ITO Grey 33 (#4)
8.76+12+6
ITO SuperGreen 45 (#4)
8.76+12+6
ITO SuperBlue 40 (#4)
12.76+12+6
Viridian Renew Laminates
Clear (#1)
6.38+12+6
Grey (#1)
6.38+12+6
Bronze (#1)
6.38+12+6
Green (#1)
6.38+12+6
SuperGreen (#1)
7.38+12+6

U Value

SHGC

Shading
Co.

Weight
m2

1.5
1.5
1.5
1.5
1.5
1.5
1.5

0.61
0.59
0.55
0.46
0.39
0.37
0.31

0.71
0.68
0.63
0.53
0.45
0.43
0.35

20
30
40
20
30
20
30

1.8
1.7
1.8

1.5
1.5
1.5

0.44
0.43
0.27

0.51
0.50
0.31

20
30
15

<1
<1
<1
<1
<1
<1
<1

1.7
1.7
1.7
1.7
1.7
1.7
1.7

1.5
1.5
1.5
1.5
1.5
1.5
1.5

0.55
0.54
0.52
0.40
0.30
0.27
0.23

0.64
0.60
0.59
0.46
0.34
0.31
0.27

35.4
40.4
45.4
35.4
35.4
35.4
40.4

14
9

<1
<1

1.7
1.7

1.5
1.5

0.58
0.40

0.66
0.46

30.5
30.5

34
26
24
16
15
12

10
8
7
6
6
5

<1
<1
<1
<1
<1
<1

1.7
1.7
1.7
1.7
1.7
1.7

1.5
1.5
1.5
1.5
1.5
1.5

0.44
0.36
0.34
0.25
0.25
0.21

0.51
0.41
0.39
0.30
0.28
0.25

35.8
35.8
35.8
35.8
35.8
40.8

47
29
31
40
25

19
15
13
17
14

<1
<1
<1
<1
<1

1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6

0.60
0.42
0.45
0.53
0.36

0.69
0.49
0.51
0.62
0.41

30.4
30.4
30.4
30.4
32.9

UV Trans.

Air

Argon

34
29
26
20
15
12
8

1.8
1.8
1.7
1.8
1.8
1.8
1.8

11
11
7

28
24
8

43
42
40
30
19
18
14

13
13
12
9
7
6
6

18
17

45
30

16
14
11
7
9
7

18
18
17
17
17
16

25
17
16
21
21

22
16
16
20
19

Notes Viridian EnergyTech Clear has been used as the backing (inside) glass of the IGU. Typical measured values of Viridian production are provided.
All performance data is determined using LBL Windows 5.2 software, NFRC 100-2001 conditions have been used. Product Name Where # appears,
ie (#2), this identifies the position of the coated surface of the glass. Glass surfaces are counted from the exterior to the interior of the building.
Nominal Thickness The glass thickness or the makeup of a Viridian ThermoTech unit. The first number is the outer glass thickness, +12 is the width
of the gap, then the thickness of the inner panel of the unit. Thickness tolerances are: 3-6mm (0.2mm); 8-12mm (0.3mm); 15mm (0.5mm);
19mm (1.0mm).

viridianglass.com

Noise reduction solutions using glass


Knowledge

The following tables take the recommended

level in the room because the level in the room is

design sound levels from AS/NZS 2107 for both

influenced by the vagaries caused by differences

recommended and satisfactory levels and lists the

in window type or window frame type.

glass to be used to achieve the desired sound


level at the inside of the glass. Satisfactory refers
to the highest levels of noise in the room which is
believed tolerable by AS/NZS 2107 for the activity
being undertaken in that room. Therefore the
recommended solution is more desirable for the
occupant than the satisfactory solution.

It should be remembered the acceptable


noise levels suggested in AS2107 may not be
suitable for all people. There are various methods
for analysing and finding a solution to a noise
problem. An accoustic consultant is an authoritative
source of information and advice for analysing
and developing solutions to noise problems.

The tables provide the solution for both traffic and

Consideration should be given to employing

aircraft noise for the building use designations

their expertise.

shown in AS/NZS 2107. The attenuation of traffic


noise in this table is represented by Rw+Ctr and
aircraft noise is represented by Rw+C.

Further information on the acoustic properties


of glass including attenuation data is available
on our website.

This table relates to the noise level at the inside


surface of the glass not necessarily the noise

Sound attenuation solutions


Type of Occupancy

External Traffic Noise


Noise Internal noise level (room side of glass)
Level Minimum Compliance
dB
Recommended
65

Board Room
(Recommended 30)
(Min. Compliance 40)

Cafeteria
(Recommended 45)
(Min. Compliance 50)

Call Centre
(Recommended 40)
(Min. Compliance 45)

Computer Room
(Recommended 45)
(Min. Compliance 50)

Design Office
(Recommended 40)
(Min. Compliance 45)

Internal noise level (room side of glass)


dB

Minimum Compliance

dB

Recommended

dB

29

4mm VFloat

36

6.5mm VLam Hush

30
29

37

10.5mm VLam Hush

30

6.38mm VLam

38

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

30

6.5mm VLam Hush

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

No standard solution

70

6.38mm VLam

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

75

10.5mm VLam Hush

39

10mm VFloat +
200mm Gap +
6mm VFloat

80

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

No standard solution

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

4mm VFloat

42

4mm VFloat

41

4mm VFloat

41

75

4mm VFloat

47

6.38mm VLam

45

4mm VFloat

46

5mm VFloat

45

80

6.38mm VLam

50

10.5mm VLam Hush

44

6.5mm VLam

45

6.5mm VLam Hush

45

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

80

10.5mm VLam Hush

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

4mm VFloat

42

4mm VFloat

41

4mm VFloat

41

75

4mm VFloat

47

6.38mm VLam

45

4mm VFloat

46

5mm VFloat

45

80

6.38mm VLam

50

10.5mm VLam Hush

44

6.38mm VLam

45

6.5mm VLam Hush

45

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

80

viridianglass.com

4mm Float

Aircraft Noise

10.5mm VLam Hush

40

6.5mm VLam Hush

Sound attenuation solutions


Type of Occupancy

General Office Areas


(Recommended 40)
(Min. Compliance 45)

Private Office
(Recommended 35)
(Min. Compliance 40)

Reception Area
(Recommended 40)
(Min. Compliance 45)

Lobby
(Recommended 45)
(Min. Compliance 50)

Airport Departure
Lounge
(Recommended 45)
(Min. Compliance 55)

Airport Passenger
Check-in Area
(Recommended 45)
(Min. Compliance 50)

Art Gallery
(Recommended 40)
(Min. Compliance 45)

Exhibition Areas
(Recommended 40)
(Min. Compliance 50)

Place of Worship
(Recommended 30)
(Min. Compliance 35)

External Traffic Noise


Noise Internal noise (room side of glass)
Level Minimum Compliance
dB
Recommended

Aircraft Noise
Internal noise (room side of glass)
dB

Minimum Compliance

dB

Recommended

dB

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

80

10.5mm VLam Hush

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

65

4mm VFloat

37

6.38mm VLam

35

4mm VFloat

36

5mm VFloat

35

70

6.38mm VLam

40

10.5mm VLam Hush

34

6.38mm VLam

40

6.5mm VLam Hush

35

75

10.5mm VLam Hush

39

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

6.5mm VLam Hush

40

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

34

80

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

10mm VFloat +
200mm Gap +
6mm VFloat

35

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

80

10.5mm VLam Hush

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

4mm VFloat

42

4mm VFloat

41

4mm VFloat

41

75

4mm VFloat

47

6.38mm VLam

45

4mm VFloat

46

5mm VFloat

45

80

6.38mm VLam

50

10.5mm VLam Hush

44

6.5mm VLam

45

6.5mm VLam Hush

45

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

4mm VFloat

42

4mm VFloat

41

4mm VFloat

41

75

4mm VFloat

47

6.38mm VLam

45

4mm VFloat

46

5mm VFloat

45

80

4mm VFloat

52

10.5mm VLam Hush

44

4mm VFloat

51

6.5mm VLam Hush

45

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

4mm VFloat

42

4mm VFloat

41

4mm VFloat

41

75

4mm VFloat

47

6.38mm VLam

45

4mm VFloat

46

5mm VFloat

45

80

6.38mm VLam

50

10.5mm VLam Hush

44

6.38mm VLam

45

6.5mm VLam Hush

45

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

80

10.5mm VLam Hush

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

4mm VFloat

47

10.5mm VLam Hush

39

4mm VFloat

46

6.5mm VLam Hush

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

29

5mm VFloat

35

6mm VLam Hush

30
29

80

6.38mm VLam

50

65

6.38mm VLam

35

10.5mm VLam Hush

30

6.5mm VLam Hush

35

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

30

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

34

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

No standard solution

70

10.5mm VLam Hush

34

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

75

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

10mm VFloat +
200mm Gap +
6mm VFloat

80

10mm VFloat
200mm Gap +
6mm VFloat

35

No standard solution

Sound attenuation solutions


Type of Occupancy

Court Room
(Recommended 25)
(Min. Compliance 35)

Library Reading Area


(Recommended 40)
(Min. Compliance 45)

Museum Exhibition Area


(Recommended 40)
(Min. Compliance 45)

Post office & General


Banking Areas
(Recommended 45)
(Min. Compliance 50)

Railway & Bus Terminal


Ticket Areas
(Recommended 45)
(Min. Compliance 50)

Restaurants
(Recommended 45)
(Min. Compliance 50)

Coffee Bars
(Recommended 45)
(Min. Compliance 50)

Houses & Appartments


near minor roads
Sleeping Areas
(Recommended 30)
(Min. Compliance 35)

viridianglass.com

External Traffic Noise


Noise Internal noise level (room side of glass)
Level Minimum Compliance
dB
Recommended

Aircraft Noise
Internal noise level (room side of glass)
dB

Minimum Compliance

dB

Recommended

dB

5mm VFloat

35

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

23

6.5mm VLam Hush

35

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

25

65

6.38mm VLam

35

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

70

10.5mm VLam Hush

34

10mm VFloat +
200mm Gap +
6mm VFloat

75

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

No standard solution

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

No standard solution

80

10mm VFloat +
200mm Gap +
6mm VFloat

35

No standard solution

10mm VFloat +
200mm Gap +
6mm VFloat

35

No standard solution

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

25

25

80

10.5mm VLam Hush

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

40

4mm VFloat

41

6.38mm VLam

38

75

6.38mm VLam

45

10.5mm VLam Hush

39

5mm VFloat

45

6.5mm VLam Hush

40

80

10.5mm VLam Hush

44

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

6.5mm VLam Hush

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

42

4mm VFloat

41

4mm VFloat

41

75

6.38mm VLam

47

10.5mm VLam Hush

45

5mm VFloat

46

5mm VFloat

45

44

6.38mm VLam

48

6.5mm VLam Hush

45

80

10.5mm VLam Hush

50

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

42

4mm VFloat

41

4mm VFloat

41

75

6.38mm VLam

47

10.5mm VLam Hush

45

5mm VFloat

46

5mm VFloat

45

44

6.38mm VLam

48

6.5mm VLam Hush

45

80

10.5mm VLam Hush

50

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

42

4mm VFloat

41

4mm VFloat

41

75

6.38mm VLam

47

10.5mm VLam Hush

45

5mm VFloat

46

5mm VFloat

45

80

10.5mm VLam Hush

50

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

44

6.5mm VLam

48

6.5mm VLam Hush

45

65

4mm VFloat

37

4mm VFloat

37

4mm VFloat

36

4mm VFloat

36

70

4mm VFloat

42

6.38mm VLam

42

4mm VFloat

41

4mm VFloat

41

75

6.38mm VLam

47

10.5mm VLam Hush

45

5mm VFloat

46

5mm VFloat

45

44

6.38mm VLam

48

6.5mm VLam Hush

45

29

6.38mm VLam

35

6.5mm VLam Hush

30
29

80

10.5mm VLam Hush

50

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

65

4mm Float

37

10.5mm VLam Hush

30

6.5mm VLam Hush

35

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

30

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

34

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

No standard solution

70

10.5mm VLam Hush

34

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

75

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

10mm VFloat +
200mm Gap +
6mm VFloat

80

10mm VFloat +
200mm Gap +
6mm VFloat

35

No standard solution

Sound attenuation solutions


Type of Occupancy

Houses & Appartments


near minor roads
Living Areas
(Recommended 30)
(Min. Compliance 40)

Houses & Appartments


near major roads
Sleeping Areas
(Recommended 30)
(Min. Compliance 40)

Houses & Appartments


near major roads
Living Areas
(Recommended 35)
(Min. Compliance 45)

Hotels & Motels


near minor roads
Sleeping Areas
(Recommended 30)
(Min. Compliance 35)

Hotels & Motels


near major roads
Sleeping Areas
(Recommended 35)
(Min. Compliance 40)

External Traffic Noise


Noise Internal noise level (room side of glass)
Level Minimum Compliance
dB
Recommended

Aircraft Noise
Internal noise level (room side of glass)
dB

Minimum Compliance

dB

Recommended

dB

65

4mm Float

37

10.5mm VLam Hush

29

4mm VFloat

36

6.5mm VLam Hush

30

70

6.38mm VLam

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

6.38mm VLam

38

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

29

75

10.5mm VLam Hush

39

10mm VFloat +
200mm Gap +
6mm VFloat

30

6.5mm VLam Hush

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

80

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

No standard solution

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

No standard solution

65

4mm Float

37

10.5mm VLam Hush

29

4mm VFloat

36

6.5mm VLam Hush

30

70

6.38mm VLam

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

6.38mm VLam

38

8mm VLam Hush +


16mm Gap +
10.5mm VLam Hush

29

75

10.5mm VLam Hush

39

10mm VFloat +
200mm Gap +
6mm VFloat

30

6.5mm VLam Hush

40

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

80

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

No standard solution

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

39

No standard solution

65

4mm VFloat

37

6.38mm VLam

35

4mm VFloat

36

5mm VFloat

35

70

4mm VFloat

42

10.5mm VLam Hush

34

4mm VFloat

41

6.5mm VLam Hush

35

35

5mm VFloat

45

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

34

75

6.38mm VLam

45

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

80

10.5mm VLam Hush

44

10mm VFloat +
200mm Gap +
6mm VFloat

35

6.5mm VLam Hush

45

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

65

6.38mm VLam

35

10.5mm VLam Hush

29

5mm VFloat

35

6.5mm VLam Hush

30

30

6.5mm VLam Hush

35

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

29

30

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

34

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

30

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

No standard solution

70

10.5mm VLam Hush

34

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

75

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

10mm VFloat +
200mm Gap +
6mm VFloat

80

10mm VFloat +
200mm Gap +
6mm VFloat

35

No standard solution

65

4mm Float

37

6.38mm VLam

35

4mm VFloat

36

5mm VFloat

35

70

6.38mm VLam

40

10.5mm VLam Hush

34

6.38mm VLam

40

6.5mm VLam Hush

35

35

6.5mm VLam Hush

40

8mm VFloat +
16mm Gap +
10.5mm VLam Hush

34

35

8mm VLam Hush +


16mm Gap +
10.5mm VLam Hush

39

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

35

75

10.5mm VLam Hush

39

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

80

8.5mm VLam Hush +


16mm Gap +
12.5mm VLam Hush

40

10mm VFloat +
200mm Gap +
6mm VFloat

Brand Names























105 AssaultGuard
106 AssaultGuard Ultra
95 Balustrade System
113 Bomb & BlastGuard
110 BulletGuard
57 ComfortHush
37 ComfortPlus
39 ComfortPlus Translucent
81 DcorColour
80 DcorFloor
77 DcorMirror
77 DcorMirror Laminate
77 DcorMirror Safe
77 DcorMirror Venetian
79 DcorPanel
68 DcorPattern
74 DcorSatin
74 DcorSatin Grey
74, 77 DcorSatin Mirror
83 Digiglass
32 EnergyTech
41 EnviroShield Performance ITO
43 EnviroShield Performance XIR
35 EVantage
105 IntruderGuard
109 JailGuard
113 MineGuard
104 Observa
63 OptiView
47 PerformaTech
93 Profilit
86 PyroGuard 40
65 Renew
73 Seraphic Design
71 Seraphic Standard
31 SmartGlass
33 SolTech
99 StormGuard
92 Structural Glazed Systems
61 SuperClear TC
45 ThermoTech
12 VFloat
27 VFloat SuperBlue
27 VFloat SuperGreen
27 VFloat SuperGrey
14 VLam
55 VLam Hush
75 VLam Soft White
75 VLam Translucent
17 VTough

Index
A

Acoustic control
54

NFRC conditions
21

Airco coating
7
AssaultGuard
105

Australian Standards
122
B
Balustrades
95
Bevelling
119

Bomb resistant
103, 113

Breakage considerations
5, 120

Bullet resistant
103, 110-111

Bushfire protection
86-87
C
Cathlite
68-69

Ceramic painted glass
71-73

Cleaning and site protection 121

Clear glass
12

Climate zones
21

Coated glass
7, 25, 18-56
ComfortHush
57
ComfortPlus
37

ComfortPlus Translucent
39

Condensation
37, 49-51
Costs
23

Crystal clear glass
61

Custom laminating
15

CVD coater
7

Cyclone resistant
99
D

Daylight
21, 22

Decoration glass
68-83
Doors
92

Double glazing
45-51
E

Edge work
119

Emissivity
25, 32-33

Energy management
22

Energy regulations / codes
21

Entrances and shopfronts
22, 92
F

Fading
13-15, 37

Float manufacture
6

Frameless entries
92
G

Gas filling (insulating glass unit) 49-51

Glass manufacture
6

Glass types
6, 7

Glazing standards and codes 122

Glue chip
68

Green Building Council
9
H

Heat soak treatment
5, 120

Heat strengthened glass
6, 17
Holes
118
I

Insulating glass units
6, 45-51
L

Laminated safety glass
6, 13-15
Lifecycle
23

Low E glass
25, 29, 31-51

Low iron
61

Manufacture and composition 6


Mirror
7, 13, 74, 77
N

Nickel sulphide
Noise

O

One way mirror
P

Performance data
PerformaTech

Physical properties

Polished wire

Privacy and overlooking
Processing

PyroGuard 40

Pyrolitic coating
R

Rating systems

Reflectivity

Renew
S


Safety glass
Satinlite

Security glass

Selecting glass

Self cleaning
SmartGlass

Soft white laminated

Solar collectors

Solar control

Solar energy spectrum

Solar heat gain coefficient

Spandrel glass

Spectrally selective glass
Splashbacks
Spotswood
Squarelite

Support structures

Sustainability Covenant

Structural assemblies

Structural glass
T

Technical advice

Textured glass

Thermal breakage

Thermal insulation

Toned glass

Toughened glass

Translucent glass
U

U Value
V

Vinyl back mirror

Visible light transmittance
W
Warranties

120
14, 54
77, 104
125-139
47
117
68
68, 74-75
118
86-87
6, 7, 32, 37
21
21, 22
7, 65
13-17, 122
68
7, 103-113
5
7, 65
31
39, 75
12
6, 21-51
22
22, 25
17, 71
22
71
69
69
90-92
9
95
90-95
141
68-69
23, 25, 27
33, 45-51
12, 27
6, 13, 17, 120, 122
41, 68-75
25
77
25
122

Technical advice and CSR


Technical Advisory Service

Acknowledgements

With an ever increasing diversity of product

Supergrey, Profilit and OptiView are trademarks

types, complex glass standards and regulatory

of Pilkington Group Limited.

building code changes, correct product


selection is becoming more difficult and ever

XIR 71 is a trademark of Southwall Technologies Inc.

more important. Todays rigorous government

Thermoplastic Spacer TPS is a trademark

regulations place the onus on the glass industry

of Kommerling.

to conform to these requirements and Viridian


can assist customers with these challenges.

Optiview is a trademark of Nippon Steel.

Our technical advisory service is able to assist

Disclaimer

with advice covering issues of glass selection,

As part of Viridians policy of continued

including conformity to the Australian and

improvement, it reserves the right, at any time,

New Zealand Glass Standards and Building

at its discretion and without notice, to discontinue

Regulations. Viridian can also co-ordinate testing

or change the features, designs, materials,

by independent bodies such as the CSIRO for

colours and other specifications of its products,

specific projects.

and to either permanently or temporarily

Viridian staff, with a broad knowledge and


background in the glass industry, can assist
with advice on both product selection and
performance characteristics. Such advice
cannothowever be a substitute for the project
specific advice of your own professional and
expert advisers.

withdraw any such products from the market


without incurring any liability. The information
provided in this document is a general guide
only and should not be treated as a substitute for
detailed technical advice in relation to individual
circumstances or particular applications of glass
products. Some images within this guide are for
illustration purposes only. Please contact Viridian
if you require further advice.

The CSR stable of building products is a virtual whos who of the building and construction industry
when it comes to building materials, there are only a few things we DONT do! The value that the
CSR brand brings to its product brands is one of strength, reliability, innovation and certainty.

VIRIDIAN (Australia)

VIRIDIAN GLASS (New Zealand)

ALL AUSTRALIAN
SALESENQUIRIES
Freecall 1800 810 403

ALL NEW ZEALAND


SALESENQUIRIES
Freecall 0800 808 060

VICTORIA
Melbourne (03) 9562 9562
Mildura (03) 5021 2921
Morwell (03) 5134 3586
NEW SOUTH WALES
Sydney 1800 810 403
Albury (02) 6021 4333
Coffs Harbour (02) 6658 4500
Newcastle (02) 4940 3700
North Ryde 1800 810 403
Tamworth (02) 6763 3600
Wollongong (02) 4271 5888

NORTH ISLAND
Auckland (09) 573 1427
Blenheim (03) 578 0850
Hamilton (07) 846 0725
Palmerston North (06) 358 8937
Tauranga (07) 547 4280
Wellington (04) 568 5251
SOUTH ISLAND
Nelson (03) 543 9077
Christchurch (03) 341 5007
Dunedin (03) 455 2280

Viridian Trade Centre


02 8396 6400
QUEENSLAND
Brisbane (07) 3365 0500
Cairns (07) 4031 5777
Townsville (07) 4775 4099
TASMANIA
Hobart (03) 6244 9700
Devonport (03) 6424 1816
AUSTRALIAN CAPITAL TERRITORY
Canberra (02) 6203 0500
SOUTH AUSTRALIA
Adelaide (08) 8348 9200
Mt Gambier (08) 8721 0000
NORTHERN TERRITORY
Darwin (08) 8981 9411
WESTERN AUSTRALIA
North Perth (08) 9444 5333
Jandakot (08) 9411 0111
Myaree 1800 847 434

Copyright of CSR Building Products Limited trading as Viridian. No part of this publication may be reproduced without the prior consent of Viridian.
For Viridian disclaimer and warranty details please visit our website viridianglass.com
Trademarks of CSR Building Products Limited 2015 AGSG

You might also like