You are on page 1of 7

Contour

digital monitoring systems

The 600 series Digital Monitoring System, designed and manufactured by BEP Marine, is made to meet the requirements of modern boating
and recreational vehicles. Electrical installations on-board the modern boat now incorporate complex AC & DC systems along with extensive tankage
for items such as fuel, fresh water, sewage and grey water. Accurate monitoring of such systems is essential, as a mal-function in any one of the above
areas could cause major damage to expensive equipment and ultimately endanger the vessel or peoples lives. The dot matrix display incorporated in
the 600 series allows for more detailed on-screen information and clarity of viewing. The screen has backlighting for easy night time viewing.

The 600-VM3 has had new features added for 2006. It offers the ability to have 3 voltage inputs
with Hi/Low alarms. It can also be configured as a bilge monitor with selectable legends for different
bilge areas. This allows the 600-VM3 to be either fully configured as a voltmeter or partially as
volts or bilge, eg: position 1 volt meter, position 2 & 3 bilge monitor. Selectable legends allow full
nformation to be shown on the screen to avoid confusion, unlike other digital meters available which
only show confusing digits. LCD screen draws 70% less than equivalent LED screens.
Selectable Legends:
Specifications:
input voltage 10-35 VDC
power consumption 45 ma
power consumption 65 ma
(back lighting on)
dimensions refer above

The 600-TG offers economical


monitoring for fresh or grey water
anks (plastic or fibreglass only). Using
600-TGSK strategically mounted well
nuts will give 4 tank levels. Supplied
with one sender kit. Second sender
ordered separately.
Also available is the RV-TS Tank
ender. Only one hole is required for
installation, the sender is sealed via
external lock nuts. Only suits tanks
with maximum depth of 280mm.

18

Voltmeter
start batt
house batt
port start
stbd start
house 1
house 2

aux batt
genset
radio batt
winch
bowthrust
van bat

Bilge monitor
bilge aft
bilge mid
bilge fwd
bilge stbd
bilge port
bilge
g mon

Systems in Operation Monitors & Panels


The 600-SOM offers the following features:
Programmable legends for functions being monitored eg, forward bilge
pump, aft bilge pump, engine room lights, salt water pump, locker lights, etc.
Selectable alarm functions with mute capability, eg.
1. Short beep for indicating an engine room light
has been switched on, recurring every 30 minutes if light is left on
2. Continuing alarm for pump operation which can be muted by alarm mute switch
Visual indication as well as audible alarm on screen to indicate function
in operation. If more than one function is alarming this will alternate on
flashing screen.
Provision for external alarm
Power supply 10-35VDC
Display is backlit for easy night time viewing

Features:
10mm red LEDs giving important systems on information
Ideal for flybridge or remote dash position. Also available with alarm and mute switch.
Backlit labels
SOP PANELS
PART No.
SOP1
SOP1-AL
SOP2
SOP2-AL

SIZE mm
HxWxD
115x127x40
115x127x40
115x239x40
115x239x40

SIZE inches
HxWxD
4.5x5x1.6
4.5x5x1.6
4.5x9x1.6
4.5x9x1.6

LABEL SHEET

LEDS

ALARM

MUTE SW

SET 1
SET 1
SET 1&2
SET 1&2

4
3+1 switch
8
7+1 switch

NO
YES
NO
YES

NO
YES
NO
YES

19

Contour

dc monitor

The 600-DCM monitor offers a comprehensive range of functions to allow full monitoring of your
batteries and charging systems. The 600-DCM monitors voltage on up to 3 battery banks, Amps for
charge and discharge and capacity remaining in amphours / percentage utilising peukerts exponent
(house bank only) with the added function of a bilge monitor allowing 24 hour monitoring of your
bilge pump. This meter is an important addition to modern battery management systems. Selectable
legends allow full information to be shown on the screen to avoid confusion, unlike other digital meters
available, which only show confusing digits. LCD screen draws 70% less than equivalent LED screens.

rate

Accu

The Fuel Gauge


For Your Batteries

Specifications:
input voltage 10-35 VDC
power consumption 45 mA
power consumption 65 ma (back lighting on)
dimensions refer page 18.

Capacity remaining in amp hours


and percentage
Voltage Monitor
Voltage monitoring for up to 3 battery banks
12 custom selectable legends as per
600-VM3 (refer page 18).
Hi /Low voltage alarms on all 3 banks
Amps charge & discharge
(on house bank only).
Meter supplied with a 450-50mv shunt
0.1 amp resolution up to 40 amps
Percentage remaining in amp hours.
(on house bank only).
Software utilizes Peukerts exponent
Suitable for use on battery banks from
60 - 3000 Amp hours
Low Amp hour alarm (for remote alarm
operation use part no. 54-27C4)
The bilge monitor function monitors
bilge pump functions 24 hours,
7 days a week. Stores bilge pump
operations and accumulated time.
Resetable when leaving boat
Function only available when third
voltmeter position is not used.

20

CONTOUR MATRIX CABLE KITS

Contour

ac monitor
The 600-ACM monitor offers full comprehensive monitoring for your AC system from
standard single line inputs to twin line systems as used in the USA (no need for additional
selector switch for AC inputs). The 600-ACM is supplied with an AC transducer, Part No:
AC-VSEN and current transformer Part No: CT-10-3 detailed below. A larger CT, Part No:
CT-HD, is also available where cables are too large to pass through the standard CT.
Diagrams below show basic installation. Selectable legends allow full information to be
shown on the screen to avoid confusion, unlike other digital meters available, which only
show confusing digits. LCD screen draws 70% less than equivalent LED screens.

AC Volts Functions
3 inputs with selectable legends
AC volts Line 1, AC volts Line 2, AC
volts L1 + L2, AC volts panel & AC
volts transfer
High / low volts alarms
(NEW) AC Volts
expanded screen
Shows all voltage inputs on one
screen
Amp Functions
2 AC amps inputs
Selectable legends AC amps,
AC amps line 1 & AC amps line 2
High amps alarm

Frequency Function
0-100 Hz
Frequency alarm
selectable for 50 or 60 Hz
Specifications:
input voltage 10-35 VDC
power consumption 45 mA
power consumption 65 mA (back lighting on)
for remote alarm operation use part
no. 54-27C4
dimensions refer page 18

C-VSEN
The AC-VSEN includes 3 voltage transformers for
up to 3 voltage inputs. Supplied with 600-ACM.
Dimensions:
69 x 69 x 50h mm
(2.75 x 2.75 x 2h inches)
Dimensions:
37.5 W x 39.2 H x 13.7 Dmm
(1.5 W x 1.55 H x .55 D)
hole size: 12mm (0.5)

CT-10-3

One CT-10-3 current transformer is supplied with


600-ACM. If a twin line system is in use, a second
CT must be ordered
CT-HD is available for
systems with large
mains cables,
too large for CT-10-3.
(ordered separately0.
Dimensions:
47mm Dia x 10.5 mm D
(1.85 Dia x .4 Depth)
hole size: 32mm (1.25)

21

Ultrasonic Tank Sender

tank level monitoring

TLM Features:
Tank level monitoring for up to 3 tanks
14 selectable legends for tank
descriptions eg. Fuel, Water, Blackwater
Hi - Low tank level alarms for 3 tanks
Tank levels displayed in graphic or
percentage format

Units displayed in litres, imperial


gallons or US gallons
Audible alarm with mute function
Power supply 10-35VDC
Display is backlit for easy night
time viewing

more info to come

Part No.

Tank sender interface module


Is only required when using VDO
(10-180 ohm) or Teleflex (240-33 ohm)
senders to produce a 0-5 Volt signal to
operate 600-TLM. Switchable link for VDO
or Teleflex signal. 10 32 V supply. One unit
per sender required.
See wiring application.
22

FUEL AND WATER TANK SENDERS


Tank Depth Fuel Water Mounting

TSTMF-15-30 N
TSTMF-30-60 N
TSTMF-60-100 N
TSSMF-15-30 N
TSSMF-30-60 N
TSSMF-60-100 N
TSTMW-15-30 N
TSTMW-30-60 N
TSTMW-60-100 N
TSSMW-15-30 N
TSSMW-30-60 N
TSSMW-60-100N

(probe Adjust Range)

150-300
300-600
600-1000
150-300
300-600
600-1000
150-300
300-600
600-1000
150-300
300-600
600-1000

YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES

TOP
TOP
TOP
SIDE
SIDE
SIDE
TOP
TOP
TOP
SIDE
SIDE
SIDE

Ultrasonic Tank Sender

tank level monitoring

new TSI Ultrasonic Tank Sender can be used on fuel (petrol or diesel), fresh water, grey water or black
ks. This means less SKUs to stock.
The TSI is programmable for the following outputs, 240-33ohm, 10-180ohm and 0-5volt.
The TSI offers low profile and standard SAE 5 hole mounting pattern, allowing it to be retrofitted to practically all other sender brands.
The TSI can be programmed for tank dimensions via a computer utalizing BEP Marines propietary TSI software, avoiding experimental
tank filling on site.
The TSI configured to a 0-5v output will connect straight into the BEP 600-TLM digital tank monitor.
When configured to a 240-33ohm or 10-180ohm output the TSI can be connected to teleflex, faria, VDO and many other popular
instrument brands.

95.27 [3 3/4"]

84.88 [3 5/16"]

19.64 [3/4"]

95.43 [3 3/4"]

0.5M

SPECIFICATIONS
Current draw

25mA with 5 volt gauge output

Tank depth

0 to 2000mm

Mounting

SAE 5 stud mounting pattern with gasket, seal and screws

Chemical resistance

Petrol, diesel, water, toilet, chemicals

BEP Marines proprietary software allows distributors or volume users to


pre-programme tank dimensions giving accurate measurement avoiding experimental
tank filling.
Software and Programming Kit available Part NO.TSI-PK
23

Contour

multifunction digital monitors

The 600 - DCTLM is designed for installations where space is not available to fit two meters.
Offering most of the same functions and settings as the 600-DCM and 600-TLM.
It offers a compact and economical installation. A full range of selectable legends for battery
banks and tanks is available in the set-up menu. Selectable legends allow full information to be
shown on the screen to avoid confusion, unlike other digital meters available, which only show
confusing digits. LCD screen draws 70% less than equivalent LED screens.

More
information
ONE SCREEN!
The 600-DCTLM is supplied with
LB-450-50mv shunt (refer page 20).
For tank sender info (refer page 22-23).

Specifications:
input voltage 10-35 VDC
power consumption 45 mA
power consumption 65 mA (back lighting on)
for remote alarm operation use part
no. 54-27C4
dimensions refer page 18

Compatable with new TS1


Ultrasonic Tank Sender
(refer page 23)
The 600-DCACM is designed for installations where space is not available for two meters.
This meter offers most of the same features and settings as the 600-DCM and 600-ACM
with the exception that the AC monitor will only receive 2 voltage and 1 current input.

24

The 600-DCACM is supplied


with LB-450-50mv and AC-VSEN
(refer page 20-21).