You are on page 1of 2

Characteristics and Applications of Different Type

Goniophotometer
According to IESNA-LM-79 standard, Goniophotometer is used for light intensity distribution
and flux test. Accordingly, Lisun Group introduced several different types Goniophotometer, the
following introduces its characteristics and application.
Lisun LSG-2000 LM-79 Goniophotometer with Rotating Mirror is an automatic light distribution
intensity 3D curve testing system. It can realize C-, A- and B- measurement solution. The
measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or
HID luminaries such as indoor and outdoor luminaries, roadway luminaries, street lamps, flood
lights and other kinds of luminaries.
Lisun LSG-1950/LSG-1950S Goniophotometer for Automotive and Signal Lamps is mainly used
to measure transportation industry luminaries such as traffic signal lamp, public transport,
train and space ship luminaries. The photometer head keeps static and faces to the teat
sample while the test samples rotates around both horizontal axis and vertical axis, so the
luminous intensity and illuminance of the tested lamp or luminaires can be tested.
Lisun LSG-1800B/LSG-1700B/LSG-1600B High Precision Rotation Luminaries Goniophotometer
carries out measuring methods of fixed location and rotating luminaries. It can work by double
pillars structure and single pillar structure to realize C-, A-and B-measurement solution, it
fully meets CIE, IEC, LM-79, GB etc standards. LSG-1800B adopts Japanese Mitsubishi Motor
and German Angle encoder System to keep the test accuracy to 0.0017degree. It is widely
used in optical industry laboratory. It is used to test for LED street luminaries, indoor
luminaries and mining luminaries photoelectric parameters.
Lisun LSG-1800BCCD/LSG-1700BCCD/LSG-1600BCCD High Precision Rotation Luminaries
Goniospectroradiometer except used in industry laboratory to test LED street luminaries,
indoor luminaries and mining luminaries photometry parameters such as space light intensity
distribution curve, Luminous intensity data, zonal luminous flux, luminaries efficiency,
luminance limitation curves and electric parameters such as voltage, current, power, power
factor and frequency. It combines a CCD spectroradiometer to test spatial spectral color
parameters. The test data can be saved as IES, LDT, CIE etc file document. This kind of format
files can be transferred by other illumination and luminaire design software such as DiaLux.
Lisun LSG-1200A Compact Goniophotometer has included a 1m dark room; it is used to
measure the luminous intensity distribution curve, intensity data, spread angle and other
parameters for Chip LED, LED Module, LED Bulb, LED spotlight and CFL Lamp. LSG-1200A can
measure the maximum size 180mm lamps.
Lisun LSG-2000 Moving Mirror Goniophotometer System is widely applied to Luminaries
manufacturing enterprise and lab, such as Sharp Electronics in Memphis TN(USA), CS TECH

MEXICO, S.A. DE C.V. (Mexico), DORADO Praha s.r.o. (Czech) etc. The reason why Lisun can
win some many customers is because we always practice the motto of right products, right
price and right service. Lisun will continue feedback good quality products and superior service
in the feature.