TECHNICAL CHARACTERISTICS

Powerful Uninterruptible Power Supply from 1kVA to 10kVA


The intelligent, true double-conversion technology, along with smart battery charger, power management, and available extended
runtime modelss are designed for networks, servers, data centers, ATMs, and medical equipment. HTI online UPS is the best cost
effective solution for all your connected equipment needs.

PERFORMANCES
True double-conversion online UPS
Output power factor 0.8
Wide input voltage range (110 V -300 V)
Programmable power management outlets
50/60 Hz Frequency Converter Mode
ECO mode operation for energy saving
Emergency Power Off (EPO) Function
DSP technology applied for 6K and up models
Smart battery charger design to optimize battery
performance
Maintenance bypass available for 6K and up models
Optional hot standby mode and N+X parallel redundancy
available for 6K and up models
Adjustable battery numbers for 6K and up models
Built-in isolation transformer (Option)

HTI

FROM 1kVA TO 10 kVA

M O DEL
CAPACITY
INPUT

Low Line Transfer

Voltage Range

Low Line Comeback

H T I 2000

OUTPUT

High Line Comeback

290 VAC 5 % or 145 VAC 5 %

290 VAC 3%

40 Hz ~ 70 Hz

290 VAC 3%

Power Factor

0.99 @ nominal voltage (100% load)

0.99 @ 100% load

Output Voltage

208/220/230/240 VAC or 110/115/120/127 VAC

208/220/230/240 VAC

3%

1%

47 ~ 53 Hz or 57 ~ 63 Hz

46 ~ 54 Hz or 56 ~ 64 Hz
3:1

3 % THD (Linear
Load),
6 % THD (Nonlinear Load)

Harmonic Distortion

Medical application

Transfer Time

EFFICIENCY

Zero

AC Mode to Batt. Mode

Zero

4 ms (Typical)

Inverter to Bypass

AC Mode

Pure Sinewave
88%

85%

Battery Mode

BATTERY

88%

12 V / 7 Ah

12 V / 7 Ah

12 V / 9 Ah

Typical Recharge Time

6
4 hours recover to 90% capacity

Charging Current (max.)

1.0 A

Numbers

Charging Voltage
Battery Type
Numbers

MANAGEMENT

Sounding every 4 seconds


Sounding twice every second
Continuously sounding
Dimension, D X W X H (mm)
Net Weight (kgs)
Dimension, D X W X H (mm)
Net Weight (kgs)

13

26

28

Smart RS-232/USB

13

83
592 x 250 x 576

13

25

27

20-90 % RH @ 0- 40C (non-condensing)


Less than 45dB @ 1 Meter
Less than 55dB @
Less than 58dB @ 1 Meter
1Meter
Supports Windows 2000/2003/XP/Vista/2008, Windows
7, Linux, Unix, and MAC
Power management from SNMP manager and web browser

*Derate to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC.
** L means long-run model

FAX: + 62-21 5325990

81

421 X 190 X 318

397 X 145 X 220


7

592 x 250 x 576

421 X 190 X 318

397 X 145 X 220

Humidity

Optional SNMP

PT. ENERPLUS SEJATI

4.0 A
273.0 VDC 1%

Sounding every second

Overload

Noise Level

18-20

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Fault

ENVIRONMENT

273.0 VDC 1%
Depending on applications

82.1 VDC 1%

41.0 VDC 1%

Battery Mode

Long-run Model

9 hours recover to 90%


7 hours recover to 90%
capacity
capacity
1.0 A

8.0 A

LCD Panel

Standard Model

12 V / 9 Ah
20

Depending on the capacity of external batteries

Low Battery

PHYSICAL

12 V / 7 Ah

82.1 VDC 1%

41.0 VDC 1%

Charging Current (max.)


Charging Voltage

INDICATORS
ALARM

89%

83%
Battery Type

Standard Model

3 % THD (Linear Load)


6 % THD (Non-linear Load)

4 % THD (Linear Load)


7 % THD (Non-linear Load)

Waveform (Batt. Mode)

Long-run Model

JL. RAYA PERIJUANGAN NO.88 DP KOMPLEK PERKANTORAN GRAHA KENCANA JAKARTA BARAT 11530, INDONESIA TEL: +62-21 5348283

50 Hz 0.1 Hz or 60 Hz 0.1 Hz

50 Hz 0.25 Hz or 60Hz 0.3 Hz

Current Crest Ratio

Telecommunications

10000 VA /8000 W

176 VAC 3% @ 100% load


110 VAC
VAC
3%
3%@
@100%
50% load
186
load
120 VAC
3% @
50% load
300VAC
3%

Frequency Range (Batt. Mode)

Financial service

6000 VA/4800 W

300 VAC 5 % or 150 VAC 5 %

Frequency Range (Synchronized Range)

IT-Networks

HTI10000

High Line Transfer

AC Voltage Regulation (Batt. Mode)

Data centers

H T I 6000

H T I 3000

1000 VA/800 W
2000 VA/1600 W
3000 VA/2400 W
160 VAC 5% or 80 VAC 5% @ 100% load
110 VAC
VAC
5%
5% or
or 85
50 VAC
VAC
5%
5% @
@ 100%
50% load
175
load

Frequency Range

APPLICATIONS
The best protection for critical systems

H T I 1000