(a) Draw the developed winding diagram with the following data:
No. of Conductors, Z= 30; No. of Poles, P = 4;
Type of Winding: DC Double Layer Simplex Progressive Lap.
Show the placements of poles, direction of current & position of brushes.
Also write the concerned winding table & sequence diagram.
(b) Draw the Single Line Diagram of a generating substation having the following main
equipment :
i) Alternators: Five, 100MW, 11 kV, 3, Y connected, 50Hz
ii) Step-up transformers: Five, 100MVA, 11 /220kV,
iii) Bus: 220kV-Double bus with a bus coupler
iv) Outgoing lines: Five, 220kV

/ Y, 3, 50Hz

v) Station auxiliary transformers: Two, 5MVA, 11 kV/400V,

/ Y, 3 , 50 Hz

Show the positions of CTs, PTs, Isolators, lightning arresters, circuit breakers.

2.
(a) Draw the developed winding diagram of double layer duplex progressive lap Winding with the
following data:
No. of slots, S = 24; No. of Poles, P = 6; No. of Commutator segments = 24
Show the placements of poles, direction of current & position of brushes.
Also write the concerned winding table & sequence diagram.
(b) Draw the one line diagram of a substation having the following equipment:
i) Incoming lines: Two, 220kV
ii) Outgoing Lines: Five, 66kV, One 11 kV
iii) Bus-bars: 220 kV-Double bus, 66kV-Double bus, 11kV bus
iv) Transformers:
(a) Three winding transformers-Two, 100MVA, 220/66/11kV, 3
(b) Auxiliary transformer-One, 5MVA, 11kV/400V, 3
v) Wave trap. Coupling condenser and Earth switch at incoming lines
Show the positions of CTs, PTs, Isolators, lightning arresters and circuit breakers.

3.
(a) Draw the developed winding diagram of a double layer lap winding for the stator of a 3-phase
Induction motor having 24 slots and 4-poles. Stator is connected in star.
(b) Draw the single line diagram of a substation having the following equipment:
i)
Incoming lines: Two,110 kV
ii)
Outgoing lines: (a) One, 110 kV (b)Four, 11 kV
iii)
iv)

Transformers: (a) Two, 10MVA, 110/ 11 kV, / Y


(b) One, 2MVA, 11kV/ 415V, Y / Y
Bus-bars: 110 kV-Duplicate bus-bar, 11 kV single bus-bar

Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers.

4.
(a) Draw the developed winding diagram for the stator of a 3-phase Induction
Motor having 24 slots, 4-pole, double layer lap winding with a coil-span of
150 E assuming a phase sequence of RYB. Stator is connected in delta.
(b) Draw the single line diagram of a 66/11 kV substation having the following equipment:
(i)
Two transformers 66/11 kV,5MVA, /Y ,3Phase
(ii)
66kV double bus-bar with bus coupler, 11kV single bus with sectionalisation
(iii)
Two incoming lines 66kV
(iv)
Two outgoing lines 66kV
(v)
Eight outgoing lines at 11kV distributed equally.
Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers.

5.
(a) Draw the developed winding diagram for the stator of an alternator having 27
slots, 4-pole, double layer lap with a phase sequence of RYB. Stator is connected in Star.
Draw the single line diagram of a 33/11 kV substation having the following equipmenti)
Incoming line: One, 33kV
ii)
Outgoing lines: Six, 11kV
iii)
Transformers: - (a) One, 9MVA, 33/6.4/0.695 kV, / Y/ Y
(b) Two, 6.3MVA, 33/11kV, /Y
Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers.

6
(a) Draw the developed winding diagram with the following data:
Number of Conductors = 36; Number of slots = 18; Number of Poles = 6
Type of Winding: DC Double layer Simplex Progressive Lap.
Show the placements of poles, direction of current & position of brushes.
Also write the concerned winding table & sequence diagram.
(b) Draw the single line diagram of a 66/11 kV substation having the following equipmenti)
Incoming line: One, 66 kV
ii)
Outgoing lines: Six, 11kV
iii)
Transformers- (a) One, 9MVA, 66 /6.4/0.695 kV, / Y/ Y
(b) Two, 6.3MVA,66/11kV, /Y
Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers.

7
(a) Draw the developed winding diagram with the following data:
Number of Poles = 6; Number of Commutator segments = 24; Number of Conductors = 48;
Type of Winding: DC Double layer Duplex Progressive Lap.
Show the placements of poles, direction of current & position of brushes.
Also write the concerned winding table & sequence diagram.
(b) Draw the single line diagram of a 66/11 kV substation having the following equipment:
(i)
Two transformers 66/11 kV,5MVA, /Y ,3Phase
(ii)
66kV double bus-bar with bus coupler, 11kV single bus with sectionalisation
(iii)
Two incoming lines 66kV
(iv)
Two outgoing lines 66kV
(v)
Eight outgoing lines at 11kV distributed equally.
Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers.

8
(a) Draw the developed winding diagram with the following data:
Number of slots = 24; Number of Poles = 6; Number of Commutator segments = 23;
Type of Winding: DC Double layer Duplex Progressive Wave.
Show the placements of poles, direction of current & position of brushes.
Also write the concerned winding table & sequence diagram.
(b) Draw the single line diagram of a substation having the following equipment:
i)
Incoming lines: Two,220 kV
ii)
Outgoing lines: (a) One, 220 kV (b)Four, 66 kV
iii)
iv)

Transformers: (a) Two, 10MVA, 220/ 66 kV, / Y


(b) One, 2MVA, 66kV/ 11 kV, Y / Y
Bus-bars:220 kV-Duplicate bus-bar, 66 kV single bus-bar

Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers.
9.
(a) Draw the developed winding diagram with the following data:
Number of Coils = 24; Number of Poles = 4; Number of Commutator segments = 24;
Type of Winding: DC Double layer Duplex Progressive Wave.
Show the placements of poles, direction of current & position of brushes.
Also write the concerned winding table & sequence diagram.
(b) Draw the one line diagram of a substation having the following equipment:
i) Incoming lines: Two, 220kV
ii) Outgoing Lines: Five, 66kV, One 11 kV
iii) Bus-bars: 220 kV-Double bus, 66kV-Double bus, 11kV bus
iv) Transformers:
(a) Three winding transformers-Two, 100MVA, 220/66/11kV, 3
(b) Auxiliary transformer-One, 5MVA, 11kV/400V, 3
v) Wave trap. Coupling condenser and Earth switch at incoming lines
Show the positions of CTs, PTs, Isolators, lightning arresters and circuit breakers.

10.
(a)

Draw the developed winding diagram for the stator of an alternator having 21 slots, 4-pole,
double layer lap with a phase sequence of RYB. Stator is connected in Delta.

(b) Draw the Single Line Diagram of a generating substation having the following main equipment :
i) Alternators: Five, 100MW, 11 kV, 3,

connected, 50Hz

ii) Step-up transformers: Five, 100MVA, 11 /220kV, / , 3, 50Hz


iii) Bus: 220kV-Double bus with a bus coupler
iv) Outgoing lines: Five, 220kV
v) Station auxiliary transformers: Two, 5MVA, 11 kV/ 400V, Y/ Y, 3 , 50 Hz
Show the positions of CTs, PTs, Isolators, lightning arresters, circuit breakers.