Professional Documents
Culture Documents
INFINITE 7 - 8
POWER AMPLIFIERS
OWNER'S MANUAL
INFINITE 7 - 8
POWER AMPLIFIERS
IMPORTANT
THE PRODUCT REQUIRES
CLASS 2 OUTPUT WIRING.
WARNING
Printed on
recycled paper.
Page 3
Precautions
Although your amplifier is protected from external faults, the following safety precautions are recommended:
1. Do not change the position of the stereo/mono mode switch unless the amplifier is first turned off.
2. There are important differences between the Stereo, Parallel and Bridge modes. Please refer to page 7 for
a detailed description of the different modes and there uses.
3. Switch off the amplifier or turn down the inputs before connecting to the in/out XLR's.
4. Do not short the ground lead of an output cable to the input signal ground. This will form a ground loop
and may cause oscillations.
5. Do not connect both channels positive outputs together in parallel or stereo modes. And never connect any
channels positive output to chassis ground.
6. Do not operate the amplifier from AC mains in excess of 10% variation above or below the selected
line voltage, and only at the specified line frequency.
Page 4
acoustics
BRIDGE
POWER
Front Panel
1.Power Switch
To turn the amplifier ON or OFF.
2.Level Controls
To control the output levels.
3.Power LED
The Power LED shows that the amplifier has been turned on.
4.Signal LEDs
When illuminated the LEDs indicate an audio signal is present at the channel's
output.
5.Limit LED
The Limit LED indicates when the limiter is active. The limiter circuit examines
the audio signal to prevent the amplifier from clipping
6.Protect LED
The protect LED lights up when the amplifier detects dangerous subsonic
frequencies, DC or thermal overload.
7.Bridge LED
Indicates when the amplifier is in bridge mode.
Page 5
Input
Output Assignment
Out1:Pin1+:Signal Ch1 Pin1-:Ground Ch1
Speaker Output:
Pin2-
Pin2+:Ground
Caution
CH1
CH2
DirectOut
Limit
Mode
SERIAL NO.:
Off
On
Parallel
Stereo
Bridge
Rear Panel
1.Input XLR
The input impedance of the balanced XLR is 20Kohms.
2.Output XLR
Linked output from the inputs
3.Stereo, Parallel & Bridge Mode Switch
Selects Stereo, Parallel or Bridge Mode. See notes below.
4.Limiter switch
Turns the limiter on and off. Best left in the on position.
5.CH1 Speakon Outputs
In stereo mode use 1+ and 1-. CH2 output is also on 2+ and 26.CH2 Speakon Outputs
In stereo mode use 1+ and 17.Bridge Speakon Outputs
In bridge mono mode use 1+ and 1-. Min 4 ohm load
8.Power Cable
AC power in 230 VAC 50/60 Hz
Page 6
Mode
Stereo
(Both CH Driven)
Bridge Mode
(Both CH Driven)
Impedance
Infinite 8
0.1%THD+N
0.1%THD+N
0.1%THD+N
0.1%THD+N
10Hz-20kHz
1kHz
10Hz-20kHz
1500
1490
2400
2388
900
890
1300
1290
4600
4585
7400
7386
3000
2987
4800
4787
1kHz
Page 7
0.01%
103 dB
INPUT SENSITIVITY
1.0 Vrms
INPUT IMPEDANCE
20k balanced
>90dB
CROSSTALK
>70dB
CMRR
SLEW RATE
DAMPING FACTOR 1kHz and Below
20:1
Input: balanced XLR output: Speakon
COOLING
AMPLIFIER PROTECTION
VOLTGE RANGE
Dimensions :
48.3 cm (19") wide, 13.5 cm (5.3") high and 44.9 cm (17.7") deep.
Weight:
Infinite 7 :
Infinite 8 :
Page 8
Service
This unit has very sophisticated circuitry and should only be serviced by a fully
trained technician.
To prevent electric shock, do not remove covers
No user serviceable parts inside
Refer servicing to a qualified technician
Worldwide Service
Service may be obtained from your local authorised service centre. To obtain service,
simply present your sales receipt as proof of purchase along with the defective unit to
an authorised service centre. They will handle the necessary paperwork and repair.
Remember to transport your unit in the original factory packaging.
1. When sending an Infinite Series product to an authorised service centre for service,
please write a detailed description of the fault and list any other equipment used in
conjunction with the faulty product. Send the fault description with the faulty
product, do not send it separately.
2. Ensure safe transportation of your unit to the authorised service centre. Ship it in
the original factory packaging if possible.
3. Do not ship the unit in any kind of rack. Ignoring this warning may result in
extensive damage to the unit and the equipment rack. Accessories are not
needed. Do not send the instruction manual, cables or any other hardware.
4. Before returning your faulty product for repair, please remember to get a return
authorisation number from the dealer whom you purchased your product from.
Failure to do so could delay the repair of your product.
Warranty Registration
Please take time to fill out the warranty registration form at the back of this manual
and return it to Void Acoustics.
Page 9
Page 10
Unit 10B, Dawkins Road Ind Est, Poole, Dorset, BH15 4JD
Tel: +44 (0)870 1651 332 Fax: +44 (0)870 1651 352
Void Acoustics
Tel :
Model
Post code :
Serial number
Date of purchase
Warranty Copy
Owner's
Warranty
Void Acoustics
Void Acoustics
Unit 10B
Poole
Dorset
BH15 4JD
UK
Post code :
Post code :
Tel :
Tel :
Serial number
Date of purchase
Model
Warranty Registration