CLIENT: CROWN AGENTS AND ZETDC

CONTRACTOR: CHINT ELECTRIC CO., LTD.


TECHNICAL DOCUMENT NO.:COMM-GN-GN-SP-1210
TECHNICAL GUARANTEES,OUTDOOR SWITCHGEAR
Description
Particulars
Item
2
132kV SF6 Circuit Breaker
2.1
Manufacturer
Type of Breaker
Makers Designation
Operating Characteristics
2.2
Type of Operating System (hydraulic or spring)
2.3
Rated Voltage
2.4
Maximum Service Voltage
2.5
Rated Frequency
2.6
Rated Continuous Current
2.7
One minute power frequency withstand voltage, dry and wet:
- to earth
- across open breaker pole
2.8
Impulse withstand voltage
- to earth
- across open breaker pole
2.9
Breaking capacity at rated voltage
-symmetrical
- asymmetrical
2.10 Making capacity
2.11 Permissible 1 second short-time current
2.12 Dynamic short-time current
2.13 Number of main breaks per pole
2.14 Dead time (for rapid auto-reclosing) interval of time between

2.15
2.16

2.17
2.18

2.19

final arc extinction in all poles on the opening operation and


the first re-establishment of current in any pole in the
subsequent closing operation
Specific creepage distance across insulators
Auxiliary Switch
- Number of free NO contacts
- Number of free NC contacts
Motor operated spring system
- Rated voltage
Duty Cycle (where O-t-CO-t-CO):
t
t
Stored Switching Sequence
Opening time (until separation of the arcing contacts)
(a) without current
(b) at 100% rated breaking current

CONTRACT NO.:EPIRP/003
CHINT PROJECT NO.: ZW.EPIRP/003
REV.
A04

Unit
Unit

132kV
Guar. Fig

kV
kV
Hz
A

ABB Beijing
SF6
LTB170D1/B-3P
BLK222
Spring
170
170
50
3150

kV rms
kV rms

345
345

kV peak
kV peak

750
750

kA
kA
kA
kV rms
kV peak

40
45
100
40/3s
100
1
300

msec
mm/kV

>31
8
8

AC 230

s
min

0.3
3
O-CO

ms
ms

20-25
20-25
SHEET NO.: TD01

CLIENT: CROWN AGENTS AND ZETDC


CONTRACTOR: CHINT ELECTRIC CO., LTD.
TECHNICAL DOCUMENT NO.:COMM-GN-GN-SP-1210
TECHNICAL GUARANTEES,OUTDOOR SWITCHGEAR
Description
Particulars
Item
2.20 Arc duration
(a) maximum on short-circuit duty
(b) test duty on which occurring
2.21 Maximum total break time from trip initiation to final arc
extinction
2.22 Maximum time from close initiation to contact touch
2.23 First-pole-to-clear factor
(a) At 100% breaking capacity
(b) At 10% breaking capacity
2.24 Maximum voltage appearing across one breaking unit (of
multibreak poles)
2.25 Maximum pressure rise in circuit- breaker due to making or
breaking current
2.26 Voltage drop across terminals of one pole at rated normal
current
2.27 Duty cycle for out-of-phase switching
2.28 Out-of-phase breaking current
(a) At 2.0 times rated voltage
(b) At 2.5 times rated voltage
2.29 Maximum switching over-voltage when breaking line charging
currents of up to 50 A
2.30 Number of switching operations at rated breaking capacity
before contact maintenance at rated short circuit current
2.31 Temperature rise of contacts at normal rated current, breaker
mounted as in service
2.32 Length of each breaking gap
2.33 Stroke of moving contacts/break
2.34 Type of main contacts
2.35 Type of arcing contacts
2.36 Type of arc control device
2.37 Method of closing (e.g. spring, hydraulic, pneumatic etc.)
2.38 Method of tripping (e.g. spring, hydraulic, pneumatic etc.)
2.39 Power consumption for :(a) 3-pole closing
(b) 3-pole opening
2.40 Number of closing coils
2.41 Number of tripping coils
2.42 Total load of heaters per 3 poles
2.43 Temperature rise above ambient
(a) Max. at rated normal current
(b) Point where maximum occurs

CONTRACT NO.:EPIRP/003
CHINT PROJECT NO.: ZW.EPIRP/003
REV.
A04

Unit
Unit

132kV
Guar. Fig

ms

22.1
T60

ms
ms

%
bar
mV

40
40
1.5
1.5
100% one break only
8
126
C-O-O-O

kA
kA
kV

10
10
249
16

65

mm
mm

68
110
COPPER
Copper-tungsten alloy
COPPER
Spring
Spring

W
W

230
230
1
2
210

65
SHEET NO.: TD02