FIFA,FTFB Workinstruction
FIFA Workinstruction_V_1.0
Nokia Siemens Networks
Nokia Siemens Networks 2/29 FIFA Workinstruction_V_1.0
Purpose:
The purpose of this document is to describe the installation of the FIFA Flexbus
Transmission Sub-module for
Nokia Siemens Networks Flexi Multiradio BTS.
INDEX:
FIFA............................................................................
.......................................................................... 3
Overview:.......................................................................
................................................................... 3
Licensing.......................................................................
.................................................................... 3
Swap cases .....................................................................
................................................................... 3
Local management................................................................
............................................................ 4
Commissioning: .................................................................
............................................................... 4
Commissioning BTS:..............................................................
...................................................... 4
Commissioning FIFA: ............................................................
...................................................... 5
Commissioning a single hop for FlexiHopper .....................................
......................................... 6
Commissioning a single hop for MetroHopper .....................................
....................................... 8
Configuration Backup............................................................
........................................................... 9
Configuring.....................................................................
.............................................................. 9
Configuring Q1 settings.........................................................
..................................................... 13
Configuring IP settings ........................................................
....................................................... 14
Setting the real time clock.....................................................
...................................................... 14
Using alarm disturbance filtering...............................................
................................................. 14
Cross-Connection:...............................................................
............................................................ 15
Software status FIFA ...........................................................
........................................................... 15
Upgrading FIFA software with FlexiHub Manager...................................
................................. 15
FIFA 1.3 SW compatibility.......................................................
...................................................... 16
Exporting information to a text file ...........................................
................................................. 16
FTFB............................................................................
....................................................................... 17
Exporting information to a text file ...........................................
................................................. 17
Establishing a connection to the node...........................................
.................................................. 17
Connecting to the LMP...........................................................

.................................................... 17
Commissioning NSN FlexiWCDMA FTFB module and FlexiHopper........................
.................. 18
with the Commissioning Wizard ..................................................
.................................................. 18
Starting the Commissioning Wizard...............................................
............................................ 18
Commissioning a single hop......................................................
..................................................... 23
Commissioning DCN...............................................................
....................................................... 26
Software:.......................................................................
.................................................................. 28
Software Update on FTFB from R1.0 to R1.1.......................................
......................................... 29
Steps...........................................................................
..................................................................... 29
Further information.............................................................
........................................................ 29
Nokia Siemens Networks
Nokia Siemens Networks 3/29 FIFA Workinstruction_V_1.0
FIFA
Overview:
The following figures present FIFA Flexbus Transmission Sub-module for
Nokia Siemens Networks Flexi Multiradio BTS.
Licensing
FIFA has 2 Flexbus interfaces. Flexbus 1 can be used without any licence and Fle
xbus 2 usage requires a
separate licence.
To activate Flexbus 2 interface an Additional Flexbus (FB) interface licence mus
t be ordered and installed for
FIFA.
Guideline_License_do
wnload_FIFA.doc
Swap cases
Swap cases are divided into two categories, which are described in the following
.
In this category standalone transmission indoor units are replaced with integrat
ed transmission indoor units
and Flexi Multiradio BTS transmission unit is replaced with a newer release.
. FIFA -> FIFA (= new release update, see Release Note)
. FIU 19E -> FIFA
2G UltraSite / MetroSite and Flexi Multiradio BTS
In this category 2G UltraSite / MetroSite is replaced with Flexi Multiradio BTS.
. ITN + FXC RRI - > FIFA
Talk BTS and Flexi Multiradio BTS
In this category Talk BTS is replaced with Flexi Multiradio BTS.
. RRIC -> FIFA
Nokia Siemens Networks
Nokia Siemens Networks 4/29 FIFA Workinstruction_V_1.0
Local management
The Flexi Multiradio BTS local management port is used for communicating with FI
FA locally. The Flexi
Multiradio BTS LMP port is an Ethernet-based interface.
FlexiHub Manager communicates with FIFA using an IP-based protocol. When connect
ing locally, the IP
address of the PC must be manually configured to the same subnet as FIFA managem
ent port. The user
must have appropriate Windows access rights to configure the PC s IP address setti
ngs.

It is recommended that you use IP address 192.168.255.130.


. LMP: 192.168.255.131
. FIFA: 192.168.255.254
If the LMP port is used, then the PC IP address should be 192.168.255.130
and the Netmask 255.255.255.0.
Commissioning:
Commissioning BTS:
- update the SW of BTS (the System detects the FIFA card)
- Start the commissioning Wizzard and go through the wizzard and configure all p
arameters according
to datafill
- Than you need to activate the Interfaces
- be aware of the Clock Interfaces
- check or configure the BTS cross connections
- after finishing the commissioning SAVE the BTS Com-file to your Laptap
- send com-file to the BTS
Nokia Siemens Networks
Nokia Siemens Networks 5/29 FIFA Workinstruction_V_1.0
Commissioning FIFA:
LogIn to FIFA using Flexi Hub Manager
Steps:
1. Connect your computer to the LMP of the BTS System Module through an Ethernet
cable.
2. Start the FlexiHub Manager program.
3. Select File ? Connect.
4. Uncheck Connect to Remote Host.
5. Select Flexi EDGE FIFA as Connection Type.
6. Enter Login Information.
Factory defaults:
User name: PAM; Password: PAM
In case the password is changed, it applies only to the node where the change ha
s been made.
7. Click Connect.
A Pop-up-Window opens User name=PAM PW=PAM
Nokia Siemens Networks
Nokia Siemens Networks 6/29 FIFA Workinstruction_V_1.0
Closing the connection to a node
Steps
1. If necessary, save any changes you have made.
2. In the FlexiHub Manager menu, select File ? Disconnect.
Expected outcome
The connection to the node is closed.
Commissioning a single hop for FlexiHopper
If you are commissioning a new site, you should commission the network element a
nd
either the single hop or the protected hop. Follow the steps in Commissioning th
e
network element first and proceed then with either the steps below or with Commi
ssioning a protected hop.
Before you start
Follow the instructions given in Starting the Commissioning Wizard and Commissio
ning
the network element.
Steps:
1 Perform the antenna fine alignment. If you are not going to perform the outdoo
r unit antenna fine
alignment now, continue
commissioning by clicking Next and skip Step 2.
2 Configure the outdoor unit settings and click Apply.
If you are aligning the near-end antenna, select Flexbus Capacity, enter the TX

Frequency value and click


Apply. The transmitter power can be off.
If you are aligning the far-end antenna, select Flexbus Capacity, enter the TX F
requency and Maximum TX
Power values, select the TX Power check box.
The incoming signal level can be viewed from the Outdoor unit status box at the
bottom of the window.
If you are going to continue working at the other end of the radio hop, the alig
nment
settings can be made now and the commissioning can be completed at a later time.
Configure the settings and then cancel the wizard if this is the case.
The modifications made will take effect immediately when you click Apply.
3 When the antenna alignment is finished, click Next. The modifications made wil
l take effect immediately
when you click Apply.
Nokia Siemens Networks
Nokia Siemens Networks 7/29 FIFA Workinstruction_V_1.0
4 Enter the Radio Interface Properties and click Next.
Enter the Radio Interface Properties according to the network plan.
Note that Unit Name, Installer and Notes are mandatory fields.
Select whether the transmitter power should be on.
Expected outcome
The single hop commissioning part of the Commissioning Wizard has been completed
.
Click Next to continue the wizard.
5 If there is a second single hop connected to FIFA (chain site)
Then
Repeat the steps above.
Nokia Siemens Networks
Nokia Siemens Networks 8/29 FIFA Workinstruction_V_1.0
Commissioning a single hop for MetroHopper
Before you start
Follow the instructions given in Starting the Commissioning Wizard and Commissio
ning the network element.
When commissioning MetroHopper, it is recommended that you commission the Slave
radio before the
Master. Therefore it is needed to go to the slave-site first or a other
technician stay there in the swap.
Note that MetroHopper does not support protected configuration. For MetroHopper
it is only possible to select
the single hop.
Steps
1 Perform the antenna fine alignment.
If you are going to perform the outdoor unit antenna fine alignment using AGC vo
ltage,
select the appropriate Antenna Alignment option and choose Commissioning Mode,
then click Next.
2 If aligning the antenna using AGC voltage
Then
Select the required channel spacing and channel number. Choose whether
aligning the near-end or far-end antenna. Click Start Alignment.
3 When the antenna alignment is finished, click Next.
The modifications made will take effect immediately when you click Start Alignme
nt.
The incoming signal level can be viewed from the Outdoor unit status box at the
bottom of the window.
If you are going to continue working at the other end of the radio hop, the alig
nment
settings can be made now and the commissioning can be completed when the other e
nd

of the hop is also operating. Configure the settings and then cancel the wizard
if this is
the case.
Enter the Radio Interface Properties and click Next.
Enter the Radio Interface Properties according to the network plan.
Note that Unit Name, Installer and Notes are mandatory fields.
When commissioning a new hop, the same temporary hop ID must be entered in the
Hop ID field at both ends of the hop. This will be replaced with a permanent hop
ID once
the commissioning has been completed.
In manual commissioning, select the channel to be used.
In autosearch commissioning, select the channels that may be used. The MetroHopp
er
units will choose one of the channels from the list automatically.
Nokia Siemens Networks
Nokia Siemens Networks 9/29 FIFA Workinstruction_V_1.0
Configuration Backup
Flexi Hub Manager -> Tools -> Configuration Backup
The FlexiHopper (Plus) outdoor unit, starting from releases FH 3.3.4, FH 5.2.4,
FH 6.6 and FHP 2.6 and
MetroHopper, starting from release 4.0 as well as FIFA support configuration bac
kup. This feature makes it
possible to create a backup copy of important unit configurations to other conne
cted units. That information
can be restored to recover from error situations or
to quickly commission a unit which has been replaced. Backups can be made automa
tically or manually with
FlexiHub Manager.
The following backup cases are possible:
. Outdoor unit settings are backed up to the indoor unit.
. Indoor unit settings are backed up to all outdoor units.
Press Backup All Units
Note:
Configuration backup is used to backup the most important
configuration settings for each unit. These settings are stored
in other parts of the network element, so that when one unit is
replaced its settings can be retrieved from the other units. For
example, the settings for a FlexiHopper outdoor unit can be
backed up to the ndoor unit. When this unit is replaced its
settings can be retrieved and used to configure the
replacement unit.
!Caution!
If automatic backup is enabled when replacing a unit, you will lose the
backup after connecting the unit to the indoor unit.
Always disable automatic backup before replacing a unit.
Configuring
Purpose
All FIFA properties and settings are viewed and edited using the Hardware View i
n FlexiHub Manager. Click
on a unit in the equipment pane in order to select it.
Steps
1. On the FlexiHub Manager View Bar, select Hardware.
The equipment pane is shown.
2. Select the appropriate unit.
Click on the unit. The settings are shown on the configuration pane on the right
.
Click the tabs to switch between pages.
3. Make sure the Properties tab is selected, detailing the properties of the sel
ected NE.klick on Flexi
EDGE FIFA and go through all tabs and fill in Site-details into the empty-fields

Nokia Siemens Networks


Nokia Siemens Networks 10/29 FIFA Workinstruction_V_1.0
Klick on FIFA HW and go through the tabs, fill in Site details which are important
:
- Unit name: Name of the Site like e.g. FIFA GE8010
Nokia Siemens Networks
Nokia Siemens Networks 11/29 FIFA Workinstruction_V_1.0
klick on OU (OutdoorUnit) and fill out necessary info`s which are important:
- UNIT Name: name must be given from source
destination HOP, like e.g. GE_8010-GE
_2002
- Installation: fill out the installation-fields (Installer, Date, Time)
Nokia Siemens Networks
Nokia Siemens Networks 12/29 FIFA Workinstruction_V_1.0
In the settings tab you can modify the transmit frequency, transmit
power, automatic transmit power control (ATPC/ALCQ), modulation, and interleavin
g settings for the outdoor
unit(s). In a protected setup, some settings are common for both radios, dependi
ng on the
protection method (hot-standby operation (HSB) or diversity protection).
Nokia Siemens Networks
Nokia Siemens Networks 13/29 FIFA Workinstruction_V_1.0
Steps:
1. LogIn to FHM (FlexiHubManager)-> go to ODU unit and start with setting of det
ails.
2. To turn the transmit power on/off, select/clear the Tx Power check box.
3. To change the transmit frequency, type in the new value in the Tx Frequency (
kHz) box or click the
arrows to adjust the frequency. The frequency step is read from the equipment.
4. To change the transmit power, type in the new value in the Maximum Tx Power (
dBm) box or click the
arrow to adjust the power.
The range of values for the transmit power is read from the equipment.
5. To change automatic transmit power control (ATPC), select the control mode fr
om the Auto TX Power
Control drop-down list. The possible operating modes for automatic transmit powe
r control are Off, ATPC,
and ALCQ.
For the ATPC or ALCQ to function, you must set a value in the ALCQ/ATPC Set Poin
t (dB) box. This value
can be obtained from transmission planning.
6. To change the interleaving mode, select a new value from the Interleave statu
s drop-down list.
Possible values for interleaver status are Off, Depth 2, and Depth 4 in 4-state
modulation mode.
Note that the outdoor unit stops transmitting while this setting is being change
d. Change the setting
accordingly also at the other end of the hop. In 16-state modulation the interle
aver status is fixed to Depth 4.
9. To change the modulation type, select a new value from the Modulation mode dr
op-down list.
Possible values are 4-state modulation or 16-state modulation. Changing the modu
lation mode settings
interrupts the traffic for one minute.
Note that 16-state modulation is a licensed feature, and may require installatio
n of a software licence.
10. In the Outdoor Unit Settings dialogue box, click Send to submit the changes
to the node.
Expected outcome
The outdoor unit settings have been configured.
Further information

Note that if the hop is operating, the settings are for the whole radio hop,
not just the near-end radio.
Configuring Q1 settings
Before you start
Make sure that FlexiHub Manager is running on your computer and a
connection to the node has been established.
Steps
1. On the FlexiHub Manager View Bar, select DCN. The DCN view is shown.
2. Select the Q1 tab.
3. View and change, if necessary, the Q1 port settings.
To change the Q1 address or the baud rate of the Q1 port,
type in the desired value or select it from the list.
When FIFA is used with BTS polling, the Q1 port address
is fixed to 4087 and the Q1 speed is set to 9600 bit/s.
This is the default rate used by the BTS.
NOTE !!!:
NOT NEEDED, BECAUSE ONLY BTS-POLLING IS
USED
In BSC polling the Q1 address must be configured in the
range 0 - 3999 according to the Q1 plan. The Q1 port
speed must be set to the same value defined for the Q1
bus in the BSC.
Nokia Siemens Networks
Nokia Siemens Networks 14/29 FIFA Workinstruction_V_1.0
4. View and change, if necessary, the Q1
branching settings.
Select or clear the boxes to achieve the desired
setting.
5. Click Send to submit the changes to the node.
Expected outcome
The Q1 settings have been set.
Configuring IP settings
Before you start
Make sure that FlexiHub Manager is running on
your computer and a connection to the node has
been established.
Steps
1. On the FlexiHub Manager View Bar, select DCN.
The DCN view is shown.
2. Select the IP tab.
The IP settings are used for local management only, and cannot be
changed. Modifications can only be made to the User Name and
Password controlling user access.
Setting the real time clock
Before you start
FlexiHub Manager is running on your computer and a connection to the
node has been established.
Steps
1. On the FlexiHub Manager View bar, select DCN.
2. Select the Time tab.
3. Check the Set Local Time in Network Element from PC Time
check box.
4. Click Send to submit new real time clock settings to the node.
Expected outcome
The real time clock has been set and the check box is cleared.
Using alarm disturbance filtering
Purpose
When enabled alarm disturbance filtering prevents the alarm display and
network management system from being flooded with repetitions of the
same alarm.

Nokia Siemens Networks


Nokia Siemens Networks 15/29 FIFA Workinstruction_V_1.0
Cross-Connection:
In case you have to forward the signal to a another BTS go to Cross Connections in
FHM
Software status FIFA
Upgrading FIFA software with FlexiHub Manager
Steps
1. Upgrade software locally or remotely using FlexiHub Manager.
a. Select Software from the View Bar or from the View menu.
b. In the Software View, select the network element from the list.
c. Check the Update check box.
d. Select the software package from the Available Software Versions list or clic
k Browse to locate the
package.
2. Click Upgrade.
Expected outcome
The software package is visible as the Inactive Software.
3. Activate the updated software.
a. Select Software from the View Bar or from the View menu.
b. In the Software View, select the software unit from the list.
c. Check the Activate check box.
d. Click Activate to activate the updated software.
Expected outcome
The inactive software becomes the Active Software.
Nokia Siemens Networks
Nokia Siemens Networks 16/29 FIFA Workinstruction_V_1.0
If SW-update is needed, tick the box in update-row and the line which equipment
(IDU or ODU) you want to
update
FIFA 1.3 SW compatibility
Compatibility with indoor units:
FIU 19E 2.1 or later
FIU 19 4.7.2 or later
FXC RRI ITN2.2 or later
AXC 2.7 (IFUE 2.2) or later
RRIC 3.3-2 or later
FTFA (FIFA) 1.0 or later
Compatibility with outdoor units:
FlexiHopper 3.3.4 or later
FlexiHopper 5.2.4 or later
FlexiHopper 6.6 or later
FlexiHopper 4E1 2.6 or later
FlexiHopper Plus 2.6 or later
MetroHopper 4.0 or later
Exporting information to a text file
Steps
1. In the Manager menu, select File ? Save As.
2. Enter the file name and save the required information.
Note that cross-connections and active alarms can be exported for
information or documentation purposes only. The information is in
text format.
Expected outcome
The information is exported to a text file.
Nokia Siemens Networks
Nokia Siemens Networks 17/29 FIFA Workinstruction_V_1.0
FTFB
Overview of FTFB-HW
Exporting information to a text file
Before you start

Make sure that Nokia Siemens Networks FlexiHub Manager software application is r
unning on your computer
and a connection to the node has been established.
Steps
1 In the Manager menu, select File >Save As and save the required information to
a file.
For Alarms, Cross-connections and performance management data, they will be save
d as text file. For
Snapshot and Configuration data, they will be saved as zip file. And the saved C
onfiguration zip file can be
imported later.
Expected outcome
The required information has been saved to a file.
Establishing a connection to the node
Connecting to the LMP
Before you start
When Nokia Siemens Networks FlexiHub Manager is used for local management, the
computer must be connected to BTS management port (LMP) via an Ethernet cable.
g Note
It is recommended to use IP address 192.168.255.130 mask 255.255.255.0 as
default setting for the Ethernet interface settings.
In case it is conflicted with FleixBTS instruction, please follow the FleixBTS i
nstruction.
Steps
1 Connect your computer to the LMP of BTS via an Ethernet cable.
2 Start the Nokia Siemens Networks FlexiHub Manager program.
3 Select Connection > Connect.
4 Select FlexiWCDMA FTFB for Connection Type.
5 Uncheck Connect to remote Host.
6 Enter Login Information.
7 Press Log In.
Nokia Siemens Networks
Nokia Siemens Networks 18/29 FIFA Workinstruction_V_1.0
Commissioning NSN FlexiWCDMA FTFB module and FlexiHopper
with the Commissioning Wizard
Starting the Commissioning Wizard
Before you start
1. Switch the power on.
2. Connect the local management port (LMP) cable between the PC and the indoor
unit. For instructions, see Connecting to the LMP.
3. Start Nokia Siemens Networks FlexiHub Manager.
Steps
1 Set up the connection to the network element.
For instructions, see Establishing a connection to the node.
2 Establish the connection in the FlexiHub Manager. Click the Connect button or
select Connect from the Connection menu.
3 On the FlexiHub Manger's NaviBar, select Commissioning to start the Commission
ing
Wizard.
The Commissioning Wizard is launched.
4 Select the Commissioning Method either Commission manually or Commission
with a file and fill in the Installer name, Notes etc.
Nokia Siemens Networks
Nokia Siemens Networks 19/29 FIFA Workinstruction_V_1.0
Commission manually and filling in the Installer name
Commission with a file and filling in the Installer name
Nokia Siemens Networks
Nokia Siemens Networks 20/29 FIFA Workinstruction_V_1.0
Choose a file to use for commissioning
Steps

1 Select the network element and radio hop(s) to be commissioned. Click the Conf
igure
Hardware button, if it is available.
If you are commissioning a new site, select the network element and either the s
ingle hop or the protected
(HSB) hop as the commissioning targets.
If you are converting the site from single mode to protected mode, you only need
to select the protected hop
for commissioning.
Clicking the Configure Hardware button turns the Flexbus power on and also set "
in use". Then it searches
for the necessary hardware for commissioning. The progress of hardware is shown.
Selecting commissioning target and scanning for hardware
Nokia Siemens Networks
Nokia Siemens Networks 21/29 FIFA Workinstruction_V_1.0
Expected outcome
Once FlexiHub Manager founds a unit, its type is shown in the table.
Unexpected outcome
In case one of the units is not found, the network element is returned to its or
iginal state.
Check the cable connections and start over.
2 Click the Next button.
3 If you are converting an existing site from single mode to protected mode,
Otherwise:
Continue commissioning the network element.
4 Enter the site information (fields marked with yellow are mandatory, others ar
e
optional), and click Next.
Enter the following information:
Equipment Name (mandatory)
Group Name (mandatory)
Site name (mandatory)
Site location (mandatory)
Installer (mandatory)
Installation date
Installation time
Notes
Unit Name (mandatory)
Nokia Siemens Networks
Nokia Siemens Networks 22/29 FIFA Workinstruction_V_1.0
5 Fill in either IP or Q1 management information depending on your network manag
ement,
and click Next.
Enter the following IP management information, in the format 255.255.255.255:
IP address
Subnet mask
User Name: (Factory settings: PAM)
Old Password: (Factory settings: PAM)
New Password
Confirm New Password
Q1 Bypass
Configuring management settings of the network element
Note
At least two Flexbus interfaces must be selected to enable Q1 bypass.
6 Set the real time clock settings, and click Next.
Set the real time clock during commissioning by selecting the Set Time in Networ
k Element from PC Time
check box.
Besides setting the clock from FlexiHub Manager, it is possible to use Network T
ime Protocol (NTP) to update

the real time clock from the network.


To use NTP, select the Enable NTP check box and select the Time Zone from the dr
opdown list.
To add a new NTP server, click the last row in the NTP Servers table. Configure
the settings as shown in the
following table:
7 Configure SNMP Settings and click Next.
Nokia Siemens Networks
Nokia Siemens Networks 23/29 FIFA Workinstruction_V_1.0
Note
In SNMP, a trap is a type of PDU (protocol data unit) used to report an alert or
other asynchronous event
about a managed subsystem.
8 Send parameters and click Next.
9 Save Commissioning information to a file and click Finish.
10 To continue with commissioning a hop, proceed with:
Commissioning a single hop
Or:
Commissioning protected hot stand-by (HSB) hop.Otherwise:
Proceed with Finishing the commissioning.
Commissioning a single hop
Steps
1 If you are not going to perform the outdoor unit antenna fine alignment now, c
ontinue
commissioning by clicking Next.
Otherwise:
Configure the outdoor unit settings and click Apply.
If you are aligning the near-end antenna, enter the TX Frequency value and click
Apply.
The transmitter power can be off.
If you are aligning the far-end antenna, enter the TX Frequency and Maximum TX p
ower values, select the
Transmitter power on check box, and click Apply.
Further information
The modifications made will take effect immediately when you click Apply.
The incoming signal level and the transmitting power level can be viewed from th
e outdoor unit status area.
If you are going to continue working at the other end of the radio hop, the alig
nment settings can be made
now and the commissioning can be completed when the other end of the hop is also
operating. Configure the
settings and then cancel the wizard if this is the case.
Nokia Siemens Networks
Nokia Siemens Networks 24/29 FIFA Workinstruction_V_1.0
Aligning the outdoor unit antenna
Note
The Flexbus/Outdoor Unit Capacity has four choices: 2 x E1, 4 x E1, 8 x E1 and 1
6
x E1.
The modulation state only has two choices: 4-state and 16-state.
2 Click Next.
3 Enter the radio interface settings and click Next.
4 Enter the following information:
Unit name
Installer
Notes
TX Frequency
Maximum TX power
5 Select whether the transmitter power should be on.
Figure 22 Configuring radio interface settings of the outdoor unit

Expected outcome
The single hop commissioning part of the commissioning wizard has been completed
.
6 In the Send Parameters page, check that the settings are correct and click Sen
d
Parameters to send the settings to the node.
After you have entered all the required settings, a summary of commissioning set
tings is displayed. It contains
all the settings you have defined for the radio(s).
Verify the values before sending them to the node. If they are not correct, go b
ack in the Wizard using the
Back button and correct the settings.
You can use the two buttons above the list to expand and collapse all items in t
he list. You can also use the
small arrows in title rows to expand and collapse individual parts of the list.
Nokia Siemens Networks
Nokia Siemens Networks 25/29 FIFA Workinstruction_V_1.0
7 Click Next to continue.
8 Check hop status.
9 Click Next to continue
Save the final commissioning report to the local drive by clicking Save to file,
and
click Finish.
You are shown the final commissioning report. The commissioning report cannot be
accessed later unless it
is saved.
Nokia Siemens Networks
Nokia Siemens Networks 26/29 FIFA Workinstruction_V_1.0
Commissioning DCN
Steps
1 Select the Mode, Address and Mask for PPP0 over Flexbus 1 and PPP1 over
Flexbus 2. There are four modes available: Hoplan (numbered), AuxFast (numbered)
,
Hoplan (unnumbered) and AuxFast (unnumbered).
Figure 35 IP Network Extensions
Note !!:
PPP data is carried inside radio frame overhead data channels. These channels ar
e called HopLAN and
AuxFast. AuxFast interface capacity is 64 - 512 kbits/s depending on the radio l
ink capacity. HopLAN data
channe capacity is 7 - 80 kbits/s depending on the radio links' capacity.
AuxFast is a synchronous channel over the radio path. User capacity is 64 kbit/s
.
There are three AF bytes reserved in the frame,
AuxFast capacity over the radio path is thus 160 kbit/s.
The capacity is needed for the data, justification control and byte synchronizat
ion (octet information) transfer.
HopLan (HL) bits are used only as internal communication channel between equipme
nts.
In FIU19/RATS/MICE configuration, this channel is used between two OUs and messa
ge is forwarded in OUs
to/from FECLAN through processor. The capacity of the channel is n x 4 kbit/s, n
= 2, 4, 8, 16 (depending on
main signal capacity).
2 If Hoplan (numbered) or AuxFast (numbered) is selected, an IP address is neede
d
to be specified. For example, in Figure 28, 100.0.0.3 is configured. If Hoplan
(unnumbered) or AuxFast (unnumbered) is selected, the IP address and Mask
fields are disabled and need to be configured in IP tab. For example, 12.12.12.1
2

is set in IP address settings for unnumbered modes.


Figure 36 PPP settings
Nokia Siemens Networks
Nokia Siemens Networks 27/29 FIFA Workinstruction_V_1.0
Note
Numbered PPP subnet mask 255.255.255.255 is invalid. Please don't use it.
3 In the Static Routing tab, a destination is needed to be specified for loopbac
k
route.
Static Routing setting
4 Click on the Send button at the bottom to commit the changes.
Expected outcome
The DCN has been set successfully
Nokia Siemens Networks
Nokia Siemens Networks 28/29 FIFA Workinstruction_V_1.0
Finishing the commissioning
Steps
1 Make any additional settings with the FlexiHub Manager.
These settings can include:
Identification data
E1 interfaces
Software updates
2 Reset performance data.
For instructions, see Resetting the counters.
3 Monitor the hop for at least half an hour.
For instructions, see Reading performance information.
4 Save as the alarm log (if needed).
For instructions, see Exporting information to a text file.
5 Save as Cross-Connections.
For instructions, see Exporting information to a text file.
6 Close the connection to the node.
For instructions, see Closing the connection to a node.
Expected outcome
The commissioning has been completed.
Software:
Details on the new FTFB MWR R1.1 SW release:
Release Notes of FTFB R1.1 SW Load A3-20100929
SW product code and version: P59304.01.
SW version: A3
SW binary file name: P59304.01_A3.bin
SIO FPGA version: 5.9
CVS tag: FTFB_R1_A1_20100929
Release Date: 2010.09.29
P59304.01_A3.bin in the .zip below
P59304.01_A3.zip
Nokia Siemens Networks
Nokia Siemens Networks 29/29 FIFA Workinstruction_V_1.0
Software Update on FTFB from R1.0 to R1.1
Steps
1. Connect to Flexi WCDMA FTFA, Flexi WCDMA FTFB or Flexi EDGE FIFA.
For more information about connecting locally or remotely, see Connecting locall
y or Connecting remotely.
2. Upgrade software.
a. Select Software from the View Bar or from the View menu.
The Software View opens.
b. In the Software View, select the network element from the list.
c. Check the Update check box.
d. Select a software package from Available Software Versions list or Browse to
locate the package.
Click Update.

Progress bar shows the status as "Downloading" during sw update. When the softwa
re package update is
completed, new sw is visible as Inactive Software.
Activate the updated software.
. Select Software from the View Bar or from the View menu.
a. In the Software View, select the software unit from the list.
b. Check the Activate check box.
c. Click Activate to activate the updated software.
The inactive software becomes the Active Software.
Further information
Software download does not cause a traffic interruption, but it slows down the m
anagement connection to the
node. Traffic may be cut when new software is activated if the respective unit i
s reset.
The activation can take several minutes.
- FIN -