Floor, Wall and Radiant

hydronic heating
Mixing Modules, Heat Exchangers and
Electrical Hot Water Heaters
Compact design is ideal for retrofit installations or new construction
Excellent heat distribution due to integrated spherical motor pump
Easy to install and service
Low cost systems

Single zone mixing module

moh1

The MOH 1 allows a reduction of the high supply temperature of


the boiler/radiator circuit (for example 160 F) to the lower
temperature level required for the floor heating (for example 95
F) by injecting hot water into the floor heating supply. The supply
temperature for the particular floor heating can be adjusted
indirectly by the flow through the control valve (model KF + RT)
or directly by an integrated constant temperature control (model
KR).
The integrated spherical motor pump ensures an even
temperature distribution on the whole surface and a constant
comfortable temperature level in the floor heating area.
In addition, the MOH 1 is equipped with an integrated overtemperature protection device, which prevents a circulation of
water with temperatures higher than 131 F through the floor
heating loops, thus preventing damage to the floor.
The room temperature control of the MOH 1 works as follows:
The control valve is opened as long as the measured room
temperature is below the set level. This can happen in two ways:
Thermostat drive with remote sensor (model KF) or
thermoelectric drive (model RT + KR) The RT-KR drive must be
connected to a room thermostat (ordered separately). A wireless
radio control is also available on request.

Max. system pressure


Max. system temperature
Max. differential pressure
Supply voltage
Power consumption
Dimensions
Distance Supply/Return
Weight

150 PSI
230 F (Radiator circuit)
131 F (Floor heating circuit)
15 PSI within radiator circuit
1 x 115 V / 60 Hz
33 Watt (pump)
L 10.4 x H 7.68 x D 3.54
1.57 Radiator connection
2.32 mm Floor heating connection
5.06 lb (2,3 kg)

Pump curve
6
5
4
3
2
1
0
0

0.5

1.5

2.5

3.5

Flow rate [US GPM]

Dimensional drawing

1.57

The MOH 1 is designed for oxygen proof floor heating systems.


The mounting bracket allows a left- or right- sided connection to
the boiler/radiator circuit. Due to an integrated bypass, the
MOH 1 can be also connected to the former used but now outdated single-pipe system. The model MOH 1 KF is specially suited
for bathrooms and other humid areas due to the non electric
thermostat with remote sensor.

Technical Data

7.67

With the MOH 1 mixing unit, floor heating systems with up to


2 loops and up to 400 Sq Ft can be easily directly connected to
a boiler/radiator loop. The MOH 1 allows additionally for a room
temperature guided control for a chosen reference room. The
surface specification 400 Sq Ft applies to an inside diameter of
the floor heating pipe of the maximum pipe length per heating
circuit should not exceed 861 Ft. For smaller pipe inside
diameters corresponding reductions must be made.

Advantages MOH 1
Compact design is ideal for retrofit installations
Excellent heat distribution due to integrated,
spherical motor pump
Simple connection to existing heating system for floor
heating systems up to 400 Sq Ft
No limitation of the boiler- radiator supply temperature, which
means that old boiler systems with high supply temperatures
up to 230F can be connected to a floor heating system.
Integrated over-temperature protection device (131 F).
The floor heating supply temperature is controllable either by
adjustment of the injected volume flow (model KF + RT) or
directly by setting the integrated constant temperature control
(model KR).

Pump head [ft]

Application and Design


Mixing module for the connection of floor heating surfaces with
up to 400 Sq Ft for one- and two-pipe systems. The MOH 1
consists of mixing base unit, spherical motor pump with on/off
switch and
6 foot power cord, pre-adjustable control valve,
room temperature guided control (see below), mounting bracket
for left or right sided connection, over-temperature protection
device (131 F), adjustable bypass for connection to one-pipe
systems, and venting device.

2.32
10.43

Design

Adjustable mixing valve

(e.g. MOH 1 KF)

Thermostatic head
Over-temperature
protection system 131F

Remote sensor
Laing spherical motor pump
with on/off-switch

Air vent

Rotor/Impeller
Supply to floor heating loop
Return from floor heating loop
Adjustable bypass

Return to boiler loop


Supply from boiler loop

moh1

Mixing units for single zone mixing

Mixing base unit (Eurocone connection 3/4") incl. spherical motor pump with on/off switch and cord (6 ft), pre-adjustable control
valve, mounting bracket for left- or right-sided connection, over-temperature protection device (131 F), adjustable bypass for
connection to single-pipe systems, air vent.
Model

Description

MOH 1 KF

Mixing unit for connection of floor heating systems up to 400 Sq Ft with room temperature guided control thermostat
(50-79F + freeze protection) with capillary remote sensor (16 Ft).

MOH 1 RT

Mixing unit for connection of floor heating systems up to 400 Sq Ft with room temperature guided control through a
thermoelectric drive for connection to a room thermostat (sold separately).

MOH 1KR

Mixing unit for connection of floor heating systems up to 400 Sq Ft with integrated constant temperature control (68-158 F)
for connection to a room thermostat (sold separately).

moh1

Accessories
Model

Description

DXG

Duplex connector (manifold with supply and return for 2 loops)

S-MOH 1 A

White galvanized steel cabinet with mounting rails and mounting hardware included, one per carton.
Dimensions: H 13 x W 12 x D 4 - 7

S-MOH 1 B

White galvanized steel cabinet incl. 2 mounting rails and mounting hardware included, one per carton.
Dimensions H 12 x W 16 x D 4 1/3

KF

Remote sensor thermostat (50 - 79 F)

RT

Thermoelectric drive for room thermostat connection

KR

Thermoelectric drive, prewired with pump for constant temperature control (60 - 158F)

Multi-zone mixing module

moh2

Design principle
A low temperature heating system can be connected to a boiler
loop using a mixing module. Control valves and circulators for
the low flow temperature loop are integrated into the mixing
module. Completely pre-assembled substations are available with
manifolds in a cabinet or board mounted.
System advantages
The MOH 2 is a low cost system used for systems with 2 to 12
individual zones, up to 2400 Sq Ft. for use in oxygen-diffusion
proof floor heating systems with additional hydraulic adjustment
capabilities. The compact, space saving design (recessed or
wall mounted cabinets available) and the use of the reliable Laing
spherical motor pump allows the system to be installed directly
in the living area if needed. The result is a low cost, simple
system that can be connected directly to the boiler loop. A
separate low temperature loop from the boiler to the floor heating
manifold is not necessary. The boiler manifolds and additional
mixing valves are also eliminated.
Systems operation
The circulator circulates the water through the floor heating
feed connection and the floor heating loops to the floor heating
return connection
When the mixing valve opens, boiler feed water is mixed to
the floor heating loop feed side and the same amount of water
is returned from the floor heating return side to the boiler
loop return side
The mixing valve adjusts the quantity of water coming from
the boiler loop to control the desired floor heating loop feed
temperature
The control valve is equipped with an adjustable knob which
can regulate the amount of water from the boiler loop that is
allowed to flow to the floor heating loop
Control units
MOH 2 mixing modules can be driven by a wide range of Laing
control units. All are especially designed for use in floor and wall
heating. Constant, room or outside temperature guided controls
are available.
All Laing control units provide continuous and sensitive
temperature settings, including a sophisticated technique to
maximize comfort. They all come standard with over-temperature
safety-protection to avoid overheat damages to the floor heating
caused by electrical power outage or defective valves. LED or
LCD signals make them easy to service.

Technical Data
Max. system pressure
Max. system temperature
Max. differential pressure
Supply voltage
Power consumption
Dimensions
Connection

150 PSI
220 F (Radiator circuit)
140 F (Floor heating circuit)
15 PSI within radiator circuit
1 x 115 V / 60 Hz
65 Watt (pump)
L 7.8 x H 16.75 x D 3.94
Boiler loop: feed connection
3/4 female thread in ball valve
Floor heating loop: feed connection
1 female thread/flange for
segmented plastic manifold

Pump curve
14
12
10
8
Pump head [ft]

Applications
Floor heating, wall heating, snow melting

6
4
2
0
0

10

12

14

Flow rate [US GPM]

Dimensional drawing
(e.g. with 6 manifolds)

Design
Automatic air purger

Laing spherical motor pump


Rotor / Impeller

Thermometer
Fill valve
Bypass valve

Boiler return side

Check valve for


filling of floor
heating loops

Drain valve

Boiler feed side

Floor heating
feed side
Presetting knob
for control valve
Sensor position for floor
heating feed temperature
Floor heating
return side

moh2

Multi-zone mixing module

Model

Description

MOH 2

Mixing unit with preadjustable control valve, circulator, adjustable bypass for boiler feed temperature guided control, fill valve,
check valve, thermometer, automatic air vent, 1/2" female thread with plug for connection of temperature immersion sensor
for BTU meter; connection to the boiler on the left with ball valves (3/4" female thread), connection for floor heating manifold
on the right (1" female thread), corrosion resistant. Laing also offers a various range of control units.

moh2

Accessories
Model

Description

VSVA

Manifold segment for feed side with valve

VSRA

Manifold segment for return side with flow meter / preadjuster

Electrical hot water heaters

ehr, epr
Applications
Radiant heating systems and surface heating systems, also
applicable as domestic hot water heating, supplemental heating
for low-energy houses, solar systems and heat pump systems,
vacation and weekend homes. Electrical heating today is often
less expensive than other heat sources thanks to the reduced
heating requirements due to improvements in insulation in new
buildings, attractive electricity rates and non-existent start-up
and stand-by losses.

and

epm

Design
(e.g. Model EPR)

Electronic constant
temperature control

Thermometer
Manometer

Advantages
Laing electrical heaters are characterized by low initial and
installation costs as well as low operation costs. No separate
heating or storage room is required. Due to the compact, spacesaving design and the use of the long-term quiet spherical motor
pump, the electrical heating system even can be installed directly
in the living area. Electrical heating systems have low maintenance
costs as burner maintenance and oil tank cleaning is not required.
No chimney sweep costs. No risk from gas or oil leakage. No
fumes or smells.

Heating
elements

Design principle
Laing electrical heating units consist of an electrical heater with
heating elements, a circulator, a safety temperature limiter, an
electronic constant temperature control unit with additional
functions, a pressurized expansion tank and a safety relief valve
and pressure gauge. All components in contact with the liquid
are corrosion resistant. A manifold can also be attached. The
electrical heating system is available on mounting rails or with
cabinet. A comprehensive range of control units is available for
additional control of the substations. Also applicable as mobile
electrical heating, e.g. as emergency heating, temporary
electrical heating during a boiler exchange and as construction
site heating.

Heating loop
feed side

Safety valve
and air vent
Heating loop
return side

Spherical motor pump

ehr

Electric single room heater


Small electric heaters with heat performance up to 2 kW sufficient
up to 360 Sq Ft, mainly intended for the heating of a single
room. It is especially suitable for bathroom floor heating during
the time of year when the central heating system is shut off. Also
for the heating of room additions or rooms in attics. Contains a
heating element of
2 kW, circulator, safety temperature
limiter, and constant temperature control. Optional timers
available. All components coming in contact with the liquid are
corrosion resistant. Also available assembled into a cabinet with
expansion tank, a manifold for 2 loops, and valves for filling.

epr

Electric apartment heater


These units are compact electric heaters with an integrated
circulator pump. Their performance ranges from 6 to 15 kW
sufficient up to 2.400 Sq Ft, sufficient for the space heating of a
single family home or an apartment. Due to their compactness
and a depth of only 4.3 they can be mounted inside a wall or
placed in a recess. All components are corrosion resistant. The
use of the Laing spherical motor pump guarantees quiet operation
over its lifetime. The integrated electronic control enables noiseless
switching of the electric heating elements. A safety temperature
limiter protects against overheating.

epm

Mobile Emergency Heater


Easy emergency heating during boiler malfunctions or
replacement, also optimal for heating building sites and when
installing underfloor heating. Mounted on a special, robust
transport trolley, it is completely ready for connection on delivery.
It consists of an electrical heater with 3 heating elements and
power step switching (3+5+5=13 kW, sufficient up to 2040 Sq
Ft), circulator, on-off thermostat (68-194F), safety temperature
limiter, pressurized expansion tank (6l), safety valve, pressure
gauge, thermometer, union connection with ball valve 1" female
thread, fill valve, corrosion resistant, and power cord.

Heat exchangers for system separation

fp
Applications
Floor heating, wall heating and outside surface heating.

Design
(e.g. Model FP 12)

Advantages
Maximum system safety due to complete separation of the boiler
loop from the floor heating loop, no corrosion due to oxygen
diffusion, no accumulation of sludge, no clogging of copper pipe
heat exchanger, limited water damage if floor heating loop is
damaged. Considerable cost advantages for multi-story buildings
due to hydraulic separation from static pressure of primary
system.

Spherical motor pump

Copper pipe coil


heat exchanger

The complexity and costs of establishing a hydronic heating


installation can be reduced significantly by using a Laing Heat
Exchanger. Instead of two different loops for the boiler and the
floor heating loop, one single loop is sufficient for both systems.
Since the silent heat exchanger can be installed right in the living
area, the second low temperature loop from the boiler through
the whole building to the floor heating loop is unnecessary. The
heat exchanger transports the heat from the boiler loop right
into the floor heating loop with maximum safety due to complete
system separation. A floor heating mixer (usually located close to
the boiler) for the floor heating loop is therefore also not necessary.
Due to complete system separation of the boiler loop from the
corrosion resistant floor heating loop, damages in the boiler loop
caused by oxygen from the floor heating loop diffusion is no longer
a problem. The complete system separation also eleminates
accumulation of rust sludge in the floor heating loop, which extends
the life of the surface heating system, and simplifies service
significantly.
Every heat exchanger can be set and controlled separately.
Therefore, individual settings for every floor heating loop in
accordance with the preferences of the inhabitants are possible.
This maximizes the comfort and a sense of well-being. This system
is also ideal and easy to install for retrofit installations in apartment
houses.
Design Principle
A low temperature heating system (i.e. floor or wall heating) can
be connected to a boiler loop using a heat exchanger. Control
valves and circulators for the low temperature loop are integrated.
Completely pre-assembled substations are available with manifolds
and expansion tanks in a flush-mounting cabinet or on mounting
rails. The Laing Heat Exchanger FP is available with heat capacity of
12 or 15 kW. A comprehensive range of control units is available for
all systems.

fp

Bolier loop
return and
feed side

Safety
valve

Floor heating
loop return
side

Floor heating
loop feed side

Pressure gauge

Air vent

Manual air vents


(primary side)

Heat exchangers
Heat exchanger for the safe system separation of boiler and floor heating loop, heating capacity model FP 12 up to approx. 12 kW, suitable for
floor area up to approx. 1.800 Sq Ft, heating capacity model FP 15 up to 15 kW suitable for floor area up to approx. 2.400 Sq Ft. All come
standard with integrated circulator, control valve on the primary side, corrosion resistant connection on the primary side R " female thread,
union fitting on the secondary side with ball valve 1" female thread, adjustable bypass for boiler feed temperature guided control. Both models
are available with pressureless or pressurized expansion tank, in flush-mounting cabinet or on mounting rails. FP 15 is particularly suited for
condensing boiler technology. A wide range of control units is available. Additional components like manifolds are also available.

BR-16 08172006 Subject to change without notice