You are on page 1of 4

Part 6 - Moving Loads

Preparation
1) Under Training Project, create MovingLoad subdirectory
2) Copy SACINP.DAT model file, SEAINP.DAT seastate file and PSIINP.DAT soil data
from MasterSlave directory to MovingLoad directory.
Modifying seastate SEAINP.DAT to include moving loads
Add load case containing only joint load(s) as load(s) to be moved. Add load case FBLV,
add joint load F001, Z direction force = -2.0 kN.
Add moving load case FBMV, choose FBLV as moving load case; select member group
VT1 as loading member group; three moving load step sequences will be added.
Moving step sequence 1: from joint F001 to F004 in one (1) step, step size = 1.0 m;
Moving step sequence 2: from joint F004 to F005 in ten (10) steps, step size = 2.1471 m;
Moving step sequence 3: from joint F005 to F006 in two (2) steps, step size = 0.75 m.
The added moving load conditions shall looks like following:
------------------------------------------------------------------------------------------------------------LOADCNFBLV
LOAD
F001
LOADCNFBMV
MOVLOD FBLIVE
MOVGRP FBLIVE
MOVSTP FBLIVE
MOVSTP FBLIVE
MOVSTP FBLIVE

-2.0000
FBLV
VT1
1
10
2

GLOB JOIN

MOVLOAD

1.000 F001 F004


2.147 F004 F005
0.750 F005 F006

------------------------------------------------------------------------------------------------------------Running Seastate program to check moving load generation


Create Seastate loading run file and check results from listing file and generated OCI file.
Using moving loads in load combination(s)
Add moving load case FBMV to load combination OPR3, load factor = 1.0.
The modified load combinations shall looks like following:
------------------------------------------------------------------------------------------------------------LCOMB
LCOMB
LCOMB
LCOMB
LCOMB
LCOMB
LCOMB
LCOMB

OPR1
OPR2
OPR3
OPR3
STM1
STM2
STM3

AREA
AREA
AREA
FBMV
AREA
AREA
AREA

1.000EQPT
1.000EQPT
1.000EQPT
1.000
1.000EQPT
1.000EQPT
1.000EQPT

1.000LIVE 1.000MISC 1.000P000 1.100VENT 1.000


1.000LIVE 1.000MISC 1.000P045 1.100VENT 1.000
1.000LIVE 1.000MISC 1.000P090 1.100VENT 1.000
1.000LIVE0.7500MISC 1.000S000 1.100VENT 1.000
1.000LIVE0.7500MISC 1.000S045 1.100VENT 1.000
1.000LIVE0.7500MISC 1.000S090 1.100VENT 1.000

Moving Loads - 1

------------------------------------------------------------------------------------------------------------Create run file and run the PSI analysis. Check load case selection and allowable stress
modifier from the generated OCI file.
Review results.

Moving Loads - 2

Load case selection line generated in OCI file including Moving load combinations:
----------------------------------------------------------------------------------------------------------------------------------LCSEL
OPR1 OPR2 OPR3 OPR4 OPR5 OPR6 OPR7 OPR8 OPR9 OPS0 OPS1 OPS2
LCSEL
OPS3 OPS4 OPS5 OPS6 STM1 STM2 STM3
-------------------------------------------------------------------------------------------------------------------------------------

Member group unity check summary report for master slave analysis:
----------------------------------------------------------------------------------------------------------------------------------* * * M E M B E R G R O U P S U M M A R Y * * *
API RP2A 21ST/AISC 9TH
MAX. DIST
EFFECTIVE
CM
GRUP CRITICAL LOAD UNITY FROM
* APPLIED STRESSES *
*** ALLOWABLE STRESSES ***
CRIT
LENGTHS
* VALUES *
ID
MEMBER COND CHECK END
AXIAL BEND-Y BEND-Z
AXIAL EULER BEND-Y BEND-Z
COND
KLY
KLZ
Y
Z
M
N/MM2 N/MM2 N/MM2
N/MM2 N/MM2 N/MM2 N/MM2
M
M
D01
D02
D03
H11
H12
H21
H22
H31
H32
H41
H42
LG1
LG2
LG3
LG4
LG5
LG6
LG7
PL1
PL2
PL3
PL4
VB1
VD1
VD2
VD3
VD4
VD5
VD6
VD7
VD8

105L-201L
205L-307L
305L-401L
1002-107L
1002-1001
2003-205L
2003-2000
303L-307L
307L-3000
405L-407L
405L-4000
103L-203L
201L-301L
305L-405L
405L-505L
507L-607L
607L-707L
701L-801L
105P-205P
205P-305P
305P-405P
405P-505L
F020-F003
F004-F020
F022-F021
F024-F026
F028-F027
F040-F041
F007-F005
F023-F004
F041-F027

STM3
0.51
OPR3
0.51
STM3 101.56
STM1
0.10
STM2
0.02
STM3
0.12
STM2
0.08
STM3
0.23
STM2
0.27
STM3
0.59
OPR3
0.31
STM2
0.10
STM2
0.19
STM3
0.30
STM3
0.19
OPR2
0.24
OPR1
0.67
OPS6
1.14
STM3
1.12
STM3
0.75
STM3
0.61
STM3
0.44
OPR1
0.71
OPR1
0.46
OPR7
0.14
OPS0
0.07
OPS2
0.04
OPS3
0.04
OPS5
0.02
OPS6
0.31
OPS3
0.04

35.8
0.0
24.0
11.1
0.0
9.9
0.0
13.9
0.0
14.1
0.0
28.1
27.7
21.7
0.0
1.0
11.3
7.7
0.0
0.0
0.0
1.0
0.0
7.5
0.0
0.0
0.0
1.8
0.0
5.9
2.6

-24.21
7.15
-12.36 -5.99
-60.35 61.27
5.68 -18.35
1.04 -2.98
3.18 -21.08
-4.55 -1.25
-10.54 -10.03
-9.81 -16.35
-13.38 16.47
-7.96 -12.73
10.31 -7.24
-21.81 -6.86
50.36 10.10
38.93 17.49
-32.47 19.98
-55.39 -2.59
-29.35 -51.67
-88.57 -50.34
-86.07
8.94
-83.57 -6.74
-81.59
7.99
-10.28-111.03
12.61 10.17
-6.94
0.65
-6.17 -4.15
-3.52
1.52
-3.77
1.13
-2.30
0.66
1.87 -49.98
4.50 -1.45

5.77
10.04
6.09
4.63
3.17
14.16
9.27
-34.81
4.46
103.97
-11.08
-9.10
-6.91
-2.27
-2.61
2.90
-44.20
166.70
13.26
-4.73
3.69
-2.10
43.51
69.63
-15.61
1.10
-2.33
-2.16
-0.91
22.77
-1.31

53.99 53.99
29.82 29.82
46.06 46.06
198.35 156.41
198.35 225.36
198.35 116.34
120.26 139.73
118.92 136.54
50.05 50.05
83.43 83.43
36.90 36.90
198.35 204.39
140.88 213.60
198.35 339.71
275.93*******
207.00*******
126.94 426.09
148.80 890.22
125.87 154.77
127.65 160.15
147.61 254.61
198.35*******
145.157565.53
148.80 161.60
118.81 268.60
128.96 492.03
137.651187.41
140.231804.26
143.473951.18
148.80 255.87
148.80 829.97

247.94
186.00
247.94
247.94
247.94
247.94
247.94
247.94
247.94
247.94
186.00
247.73
247.73
247.73
344.10
251.90
186.00
186.00
247.94
247.94
247.94
247.94
186.00
186.00
186.00
186.00
186.00
186.00
186.00
186.00
186.00

247.94
186.00
247.94
247.94
247.94
247.94
247.94
247.94
247.94
247.94
186.00
247.73
247.73
247.73
344.10
251.90
186.00
186.00
247.94
247.94
247.94
247.94
186.00
186.00
186.00
186.00
186.00
186.00
186.00
186.00
186.00

C>.15A
C>.15A
EULER
TN+BN
TN+BN
TN+BN
C<.15
C<.15
C>.15A
C>.15A
C>.15A
TN+BN
C>.15A
TN+BN
TN+BN
C>.15B
C>.15A
C>.15B
C>.15A
C>.15A
C>.15A
C>.15B
C<.15
TN+BN
C<.15
C<.15
C<.15
C<.15
C<.15
TN+BN
TN+BN

35.8
32.1
24.0
21.0
16.6
18.7
13.8
13.9
23.0
14.1
18.4
29.8
29.1
23.1
1.0
1.0
11.3
7.7
29.6
29.1
23.1
1.0
1.3
7.5
5.8
4.3
2.8
1.8
1.2
5.9
2.6

Moving Loads - 3

35.8
32.1
24.0
11.1
16.6
9.9
13.8
13.9
11.0
14.1
8.5
29.8
29.1
23.1
1.0
1.0
11.3
7.7
29.6
29.1
23.1
1.0
1.3
7.5
5.8
4.3
2.8
1.8
1.2
5.9
2.6

0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85

0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85

VT1 F004-F001 OPR1


1.17
1.0
13.87-197.03 33.54
148.80******* 186.00 186.00
TN+BN
1.0
1.0 0.85 0.85
W01 8011-807L OPR1
1.70
5.0
-7.55-232.99
9.87
117.00 246.83 148.80 186.00
C<.15
5.0
5.0 0.85 0.85
W02 7017-705L STM3
1.49
6.0
1.63-158.72-168.54
198.35 217.27 198.35 247.94
TN+BN
6.0
6.0 0.85 0.85
W03 8001-8005 OPR3
0.55
5.0
7.57 63.96 10.55
148.80 234.71 148.80 186.00
TN+BN
5.0
5.0 0.85 0.85
-------------------------------------------------------------------------------------------------------------------------------------

Moving Loads - 4