You are on page 1of 3

SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAUDI ARAMCO INSPECTION CHECKLIST

SAIC NUMBER

Location, Depth of Trench/Boreholes & Elevation for Types I


- V Fences Inspection
PROJECT TITLE

SAIC-M-1003
WBS / BI / JO NUMBER

EQUIPMENT ID NUMBER(S)

EQUIPMENT DESCRIPTION

LAYOUT DRAWING NUMBER

REV. NO.

SCHEDULED INSPECTION DATE & TIME

ACTUAL INSPECTION DATE & TIME

REFERENCE

A1

General excavation shall be performed after clearing and grubbing has


been completed.

SAES-A-114
Sec. 7.1

A2

Excavation shall be performed as required by the IFC Drawings to the


dimensions, grades, elevations, formwork if required, and with alowance
for compaction equipment.

SAES-A-114
Sec. 7.2.1

A3

Over-excavated forms shall be back filled or leveled with F'c=2000 psi @


28 days blinding concrete.

SAES-A-114
Sec. 7.2.3

A4

Formwork is not required for fence or post anchor foundations.

A5

Corner, end and gate post foundation shall be a minimum 300mm


diameter and 1075mm deep for fence types I, II, III and V.

A6

Special Gate Posts over 175mm O.D. shall have foundations minimum
300mm diameter and 1320mm deep for fence types I, II, III and V.

A7

Line Post foundations shall be a minimum 250mm diameter and 1075


mm deep for fence types I, II, III and V.

A8

Brace post foundations shall be a minimum of 250mm diameter and


940mm into the ground measured at the hole centerline for fence types I,
II, III and V.

Drawing
AC-036680
Sht. NO. 1

A9

Type VI fencing posts shall be painted with adhesive, wrapped with one
wrap of pipe wrapping, and painted with a top coat of adhesive to extend
25mm above top of concrete and 125mm into the concrete.

Drawing
AC-036681
Sht. NO. 1

A10

Type VI, corner and gate posts shall have foundations a minimum of
300mm diameter and 650mm into the ground from grade elevation.

A11

Type VI line posts shall have foundations a minimum of 250mm diameter


and 650mm into the ground from grade elevation.

A12

Type VI Brace posts shall have foundations a minimum of 250mm's


diameter and 630mm into the ground measured at the centerline.

A13

Saudi Aramco Security Fencing only shall have fence anchor blocks
minimum 300mm deep and 150mm wide cast from post froundation to
post foundation with the top surface flush with grade elevation.

Drawing
AC-036680
Sht. NO. 1

A14

One 8mm reinforcing bar shall run the full length of the anchor block at
the block centerline with 75mm's clearance at the ends for concrete.

Drawing
AC-036680
Sht. NO. 1

Page 1 of 3

PLANT NO.

EC / PMCC / MCC NO.


MH's SPENT

TRAVEL TIME

SAUDI ARAMCO USE ONLY

CONTRACTOR INSPECTION LEVEL

Location & Depth Inspection

SYSTEM ID.

QUANTITY INSP.

SAUDI ARAMCO INSPECTION LEVEL

CIVIL-

CONTRACTOR / SUBCONTRACTOR

PURCHASE ORDER NUMBER

SAUDI ARAMCO ACTIVITY NUMBER

ACCEPTANCE CRITERIA

QR NUMBER

18-May-05

EQPT CODE

SAUDI ARAMCO TIP NUMBER

ITEM
No.

DATE APPROVED

Drawing
AC-036680
Sht. NO. 1
Drawing
AC-036680
Sht. NO. 1
Drawing
AC-036680
Sht. NO. 1
Drawing
AC-036680
Sht. NO. 1

Drawing
AC-036681
Sht. NO. 1
Drawing
AC-036681
Sht. NO. 1
Drawing
AC-036681
Sht. NO. 1

WORK PERMIT REQUIRED?

PASS

FAIL

N/A

RE-INSP DATE

SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAUDI ARAMCO INSPECTION CHECKLIST


Location, Depth of Trench/Boreholes & Elevation for Types I
- V Fences Inspection
PROJECT TITLE

ITEM
No.

A15

SAIC NUMBER

SAIC-M-1003
WBS / BI / JO NUMBER

ACCEPTANCE CRITERIA

REFERENCE

One 8mm reinforcing bar shall run the full length of the anchor block
along the block centerline with 75mm's clearance at the ends, 100mm
below the top of concrete elevation with triangular projections for
connecting the chain link fabric 150mm's from the ends and spaced at
600mm on center in between. Turn downs shall exist at the ends,
150mm's long.

Drawing
AC-036680
Sht. NO. 1

Fencing Details Inspection

B1

The top of the fence shall follow the profile of the ground.

Drawing
AA-036677
Sht. NO. 1

B2

Corner panels, panels on either sides of gates and tensioning panels


shall have a brace rail at the fencing centerline and a diagonal truss rod
running from post foundation to the brace rail.

Drawing
AA-036677
Sht. NO. 1

B3

The fences' wire fabric shall extend from 25mm clear of grade elevation
to 2425 mm's up from grade elevation.

Drawing
AA-036677
Sht. NO. 1

B4

Seven (7) bar bands shall be used to connect the fences wire fabric at
corner posts, line posts, end and gate posts. They shall be spaced at
360mm's on center on corner end and gate posts and 350mm on line
posts.

Drawing
AA-036678
Sht. NO. 1

B5

Security Fencing types II and III shall have double corner extension arms
with 6 strands of barbed wire on the tops of all corner posts.

Drawing
AA-036678
Sht. NO. 1

B6

Security Fencing types II and III shall have double extension arms with 6
strands of barbed wire on the tops of all line posts.

Drawing
AA-036678
Sht. NO. 1

B7

Security Fencing types II and III gate posts shall have three (3) type I
bands for connecting the barbed wire at top.

B8

Security Fencing Type II shall have double corner post extensions for
connecting the barbed wire.

B9

Type IV shall have single corner and line post extensions for supporting
3 strands of barbed wire at 450 from horizontal.

B10

Winding brackets shall be provided for connecting top and bottom


tensioning wires for fence types III, IV and V, plus at the bottoms only for
type II fencing.

B11

Type I bands shall be provided to connect 10mm diameter truss rods,


top, bottom and brace rails.

B12

Gates shall be provided with at least 2 hinges per leaf, more as required
by IFC Drawings or specifications.

B13

Gate leaves shall be provided with latches, fork catch bars, lock keepers,
strecher bars for wire fabric, plunger rods, hook bolts and diagonal truss
rods.

Drawing
AB-036679
Sht. NO. 1

B14

Walk gates shall have a top rail and any barbed wire shall be continuous
over the top of the walk gate.

Drawing
AB-036679
Sht. NO. 1

Page 2 of 3

Drawing
AA-036678
Sht. NO. 1
Drawing
AA-036678
Sht. NO. 1
Drawing
AA-036678
Sht. NO. 1
Drawing
AA-036678
Sht. NO. 1
Drawing
AA-036678
Sht. NO. 1
Drawing
AB-036679
Sht. NO. 1

DATE APPROVED

QR NUMBER

18-May-05

Civil

CONTRACTOR / SUBCONTRACTOR

PASS

FAIL

N/A

RE-INSP DATE

SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAUDI ARAMCO INSPECTION CHECKLIST

SAIC NUMBER

Location, Depth of Trench/Boreholes & Elevation for Types I


- V Fences Inspection
PROJECT TITLE

DATE APPROVED

SAIC-M-1003
WBS / BI / JO NUMBER

ITEM
No.

ACCEPTANCE CRITERIA

REFERENCE

QR NUMBER

18-May-05

Civil

CONTRACTOR / SUBCONTRACTOR

PASS

FAIL

N/A

RE-INSP DATE

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-A-114 -- Excavation and Backfill, 28 April 2004
2- AC-036681, Sht. 1 -- Perimeter Fencing for Onshore Helipads, Footing Details, Type IV Fence, 1 June 1992
3- AC-036680, Sht. 1 -- Saudi Aramco Security and General Fencing, Footing Details, 3 March 1997
4- AA-036679, Sht. 1 -- Saudi Aramco Security and General Fencing, Gate Details, 4 February 1990
5- AA-036678, Sht. 1 -- Saudi Aramco Security and General Fencing, Post and Fabric Details, 4 January 1990
6- AB-036677, Sht. 1 -- An Overview (Architectural), Saudi Aramco Security and General Purpose Fencing, 2 March 1990

Contractor / Third-Party

Saudi Aramco

Construction Representative*

PMT Representative

Work is Complete and Ready for Inspection:


Name, Initials and Date:

T&I Witnessed

QC Record Reviewed

Work Verified

T&I Witnessed

QC Record Reviewed

Work Verified

T&I Witnessed

QC Record Reviewed

Work Verified

Name, Initials and Date:

QC Inspector

PID Representative
Performed Inspection

Work / Rework May Proceed

Name, Initials and Date:

Name, Initials and Date:

QC Supervisor

Proponent and Others


Quality Record Approved:

Name, Sign and Date:

Name, Organization,
Initials and Date:

*Person Responsible for Completion of Quality Work / Test

Y = YES

Page 3 of 3

N = NO F = FAILED