Type series booklet

3400.51/2--10

60 Hz

Submersible Borehole Pumps

Applications
---------

Submersible Borehole Pumps

Drinking and service water supply


Irrigation and spray irrigation
Lowering and maintaining ground water levels
Pressure boosting
Fountains
Mining, offshore, tank farms
Building services systems
VDS sprinkler systems

S 100D, UPA 100C, UPA 150C, UPA 200,


UPA 200B, UPA 250C, UPA 300,
UPA 350, BSX - BSF, UPZ

Operating Data

Capacity . . . . . . . . . . . . . . . . . . Q up to 1080 m3/h (300 l/s


or up to 5000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . H up to 460 m
Temperature of fluid handled . . t up to +50 oC
Speed . . . . . . . . . . . . . . . . . . . . n 3500 rpm
Supply voltage . . . . . . . . . . . . . U up to 10,000 V

Design
Single-- or multistage centrifugal pumps in pump shroud or in
ring--section design. Radial or mixed flow hydraulic systems;
reduced impeller diameters also available in some cases. The
stage casings of radial pumps are connected by metal straps,
those of mixed flow pumps by stud bolts. Suction casing fitted
between pump and motor. Suction casing equipped with
strainer to protect the pump from coarse particles in the fluid.
Pumps with check valve or connection branch on option.
Available with threaded or flanged end on option.
Particularly suitable for vertical installation in narrow deep wells.

Pump Designation (Example)


UPA

200 B --

80 / 5 b

Type series
Minimum well diameter (mm)
(for ex.: 200 mm = 8 inches)

Design status
Capacity (Qopt at 50Hz)

m3/h (4 up to 10 inches) 1)
l/s (12 inches and above)

Number of stages
Reduced impeller diameters
1)

Available automation products:

UPA 200 -11 + 14: Q in l/s.

Motor Designation (Example)


UMA 250 D 110 / 2 1
Type series
Well diameter (mm)
(for ex. 250 mm = 10 inches)

Design status
Rated power PN for 50 Hz (kW)
Number of poles
Winding insulation

Hyamaster
(UPA 200 and UPA 300)

Complete Range
The complete submersible borehole pump range comprises
pump models for capacity up to Q = 2500 m3/h (695 l/s) and
heads up to H = 1500 m.
The submersible motor range covers sizes for power ratings up
to P = 3500 kW (4700 hp) and voltages up to U = 10,000 V for
50 and 60 Hz.
In addition, a special range is available which features
submersible motors with a higher number of poles.

Certification
Quality management certified to ISO 9001

60 Hz
Contents

Submersible Borehole Pumps


Page

The 60 Hz Submersible Borehole Pump Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


Operation with Soft Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation with Frequency Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Installation Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Submersible Borehole Pump Selection for Deep Wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Request for Quotation (Form) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Head Losses in the Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Pump Sets 4 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pump Sets 6 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Pump Sets 8 Inches / 10 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Pump Sets 12 Inches / 14 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Pump Sets 16 Inches and Above . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Typical Tenders: 4 to 14 Inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Submersible Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Flow Velocity v Past the Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

60 Hz
What can you expect from the Booklet
Submersible Borehole Pumps?
The information provided can help you make a
-- quick
-- first rough selection
-- on your own
to find a suitable KSB submersible borehole pump for your
application. We have kept the volume of the catalogue down to
what we think is the absolute minimum. For the 4 to 14 inch
range, you will find the following information on the pump
selected:
-- pump series, size and number of stages,
-- motor series, size, power, amperage and allowable
temperature,
-- starting method, supply voltage and type of installation,
-- material variants and
-- major dimensions and weights.
You may also complete, to the extent possible, the request for
quotation on page 9.
You will then receive as soon as possible a detailed quotation
and, if required, additional literature on KSB submersible
borehole pumps from the nearest KSB sales branch.

Submersible Borehole Pumps

General
Information on fields of application, available models, type of
installation, direction of rotation, coating, connection to power
supply and speed control is provided in the detailed sections for
the relevant type series.

Pump Efficiency
The characteristic curves for UPA 200/200B and larger pumps
show pump efficiency for the maximum and optimum (reduced)
impeller diameter (for ex. c). The efficiency of pumps with a
low number of stages or considerably reduced impeller
diameter (for ex. d, e) is lower than the value shown; it is
given in the individual characteristic curves specifically
prepared for the quotation.

Dry Running Protection


For use in wells with marked water level fluctuations or
temporary low yield we strongly recommend installing dry
running protection equipment (Accessories).

Application Temperatures

Benefits at a Glance
+
+
+
+
+
+
+
+
+

Full range of products


High-tech equipment
Optimum material selection
Maximum efficiency
Functional reliability
Long service life
No maintenance
Clean technology
Customer focus

The submersible borehole pumps are, as a standard, suitable for


use in water with temperatures of up to t = +30 oC. An
indispensable requirement for this is a flow velocity of v = 0.2 m/s
past the motor. This requirement is met, for example, when the
pump is installed in a deep well above the well screen / filter, etc.
With certain restrictions, some motor sizes may also be used
in water with temperatures of up to t = +50 oC and for operation
without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).
The details below provide data of adequate accuracy for the
allowable temperature as a function of the type of installation,
motor size and flow velocity v past the motor:
Vertical installation:
-- DN 100 / DN 150:
tallow = tmax1) irrespective of flow past the motor.
-- UMA 150D/200D:
v = 0 m/s . . . . . . tallow tmax1) -- 5 oC,
v 0.2 m/s . . . . tallow = tmax1),
v 0.5 m/s . . . . tallow tmax1) + 5 oC.
-- UMA 250D:
v = 0 m/s . . . . . . Please consult manufacturer,
v 0.2 m/s . . . . tallow = tmax1),
v 0.5 m/s . . . . tallow tmax1), + 5 oC.
1)

Values taken from tables on pages 15, 16 etc., 27, 28 etc..

Horizontal installation:
The principle is the same as for vertical installation.
Exception: Pumps with UMA 250D motors.
These units must always be equipped with a flow inducer
sleeve. The flow inducer sleeve is not required, if the given
pump is equipped with a motor having a 10 % higher power
rating.
For all pump sets:
For a flow velocity of v 0.5 m/s and horizontal installation,
check back with the manufacturer.

60 Hz

Submersible Borehole Pumps

The 60 Hz Submersible Borehole Pump Range

" UPZ 1)
BSX, BSF 1)

(16 inches)

" UPA 100C


(4 inches)

" UPV 200


(8 inches)

" UPA 200


(8/10
inches)

" S 100D
(4 inches)

" UPA 150C


(6 inches)

" UPA 200B

(8/10 inches)

" UPA 300, 350


(12/14 inches)

" UPA 250C

(8/10 inches)

60 Hz

Submersible Borehole Pumps

Operation of KSB Submersible Borehole Pumps with Soft Starters


Soft starters electronically reduce the incoming line voltage
and, hence, the initial starting torque and starting current of
electric motors. During run--up they gently ramp up the applied
voltage to the motor.
In the case of submersible motors, the extremely slim design
and consequential small moments of inertia result in special
characteristics, which differ strongly from normal asynchronous motors.

Effects on submersible borehole pumps


-- Starting current approx. 40% to 65% of IA required for
d.o.l. starting.
-- Run-up time tH increased to approx. 1s to 3s compared
with approx. 0.2s to 0.5s for direct-starting.
-- Starting torque MA roughly 1/4 of the direct-starting torque.
-- No current or torque peaks (IA, MA), as in star-delta
switching arrangement.
-- Hydraulic pressure surges (waterhammer) upon starting
and stopping of the pump can be reduced, but not fully
eliminated. Therefore, soft starters are not suitable for
solving water hammer problems.
This would require the use of hydraulic control equipment
or a frequency inverter. To prevent effects due to power
failure, additional measures are required.

Note
Conspicuous noise or vibrations during run-up could well be an
indication of incorrect settings on the soft starter. This might be
due to exceeded ramp--up periods, incorrect operating mode
(setting), activated special functions, etc.

Soft starter settings


Parameter / Function

Setting

Comments

Minimum starting voltage

40% of the motors rated voltage

Ramp time / acceleration


(run-up) time

< 4s

Ramp time is not identical with the motors


actual running-up time

Current limitation

IA / IN preset to approx. 3.5

Should only be altered with allowance for


tH < 4s

Deceleration (run-down) time /


stop ramp

Deceleration time tA < 4s

Better without a ramp.

Special functions, e.g.:


-- special pump function
-- kick-start / boost function
-- speed adjustment
-- Current controller
-- cos / economy function
-- delayed starting

OFF

Do not use, as they tend to be troublesome,


particularly in submersible borehole applications.

Voltage [%]

During operation the soft starter must be bridged (bypass). This helps to avoid losses at the machine and motor to secure proper
permanent operation.

120
100
80

Run-up

Operation

Run-down

60
40
20
0
4s

Time [s]

4s

60 Hz

Submersible Borehole Pumps

Pump Operation with Frequency Inverter


In principle, the motors of submersible borehole pumps can
also be run on a frequency inverter. As submersible motors
differ from conventional standardized motors in terms of
bearings, moment of inertia, insulation, temperature increase,
loss distribution and heat distribution, the following parameters
must be observed:
-- Maximum allowable acceleration time (start ramp)
-- Maximum allowable deceleration time (stop ramp)
-- Minimum frequency
-- Maximum operating frequency
-- Maximum permissible voltage increase velocity and peak
voltages
-- Control principle of frequency inverter

Maximum Allowable Acceleration Time (Start


Ramp) and Deceleration Time (Stop Ramp)
The plain bearings of the submersible motor operation below
the minimum frequency fmin do not tolerate (operation in mixed
lubrication range).
For this reason, the acceleration period from standstill to
minimum frequency fmin should not exceed 2s. The same
applies to the deceleration period.

Minimum Frequency
Minimum frequency fmin (Hz)
Motor size

DN 100
DN 150

Vertical
installation

30

Horizontal
installation

30
----

UMA 150D
UMA 200D
UMA 250D

20

30

30

35

UMA 300D /2
UMA 300D /4

Maximum Operating Frequency


Frequency inverter operation above the nominal frequency
(50Hz / 60Hz) of the pump unit must be avoided so as, to
prevent motor overload.

Maximum Permissible Voltage Increase Velocity


and Peak Voltages
Excessive voltage increase velocities and excessive peak
voltages will reduce the service life of the winding insulation.
For this reason, the following limits must be adhered to:
-- Maximum voltage increase velocity:
du/dt 500 V/s
-- Maximum peak voltages to earth:
Low-voltage motors 1 kV:

J1 insulation 600 V
J2 insulation 800 V

Note: Compliance with these limits can usually be assured by


means of a sine filter or du/dt filter.

Control Principle of Frequency Inverter


The control principle of the frequency inverter must correspond
to linear U/f curve control. If other control principles are
employed, such as field-oriented inverters, inverters with DTC
or NOF, the manufacturer of the frequency inverter must ensure
that the special requirements of submersible motors (very small
moment of inertia, electrical data) are taken into account.

60 Hz

Submersible Borehole Pumps

Typical Installation Positions


a)

Vertical Installation
(deep well, pump sump, etc.)

CAUTION:

The construction of the well head must meet the relevant


regulations of the competent authorities! The unit must never
be installed with its suction strainer exactly at the level of the
well screen / filter!

Before installing the unit in narrow deep wells we recommend to


check narrow boreholes for dimensional accuracy over their
entire length, e.g. by inserting a pipe of the length and biggest
outside diameter of the pump unit. Sharp bends or bottlenecks
can make installation difficult or even impossible.
The unit is supported on the well head by supporting clamps
(low-weight units and low submergence) or a supporting flange.
The construction of the well head must meet the relevant
regulations of the competent authority.
5

Ht

Hh
3

He

B
B

TF

1
2
3
4
5
6
7
8
9

Submersible borehole pump


Riser pipe
Cable tie
Supporting flange / Well head
Pressure gauge
Shut-off valve
Power supply cable
Control box
Well screen / filter

D
TB
TF
He
Hh
Ht
Fig. 1

=
=
=
=
=
=

TB
9

Cooling / Suction shroud

Fig. 2

b)

Installation in a pump sump

3400:50

Horizontal Installation
(in reservoirs, mine shafts, etc.)

CAUTION:
The instructions given in a) Vertical installation shall also apply
by analogy to horizontal installation, when the pump unit is fitted
on mounts (pedestals / supporting frame) supplied by us. If the
pump and motor are supplied ready mounted on a supporting
frame, on-site alignment of pump and motor will not be
necessary. If this is not the case, the relevant installation /
assembly drawing must be ordered, giving the following details:
-- installation height (floor clearance),
-- spacing of supports,
-- submergence X
The ground / foundation must be level and of sufficient
load-bearing capacity to accept the weight of the unit with
supports.
Air intake from an inlet arranged above the water level is not
permitted.

D
3410:70/4

Inside well diameter


Well depth
Well screen / filter depth
Installation depth
Static water level
Dynamic water level (Pumping water level)
Vertical installation (in deep well, pump sump, etc.)

The suspension arrangement of the pump unit must be


designed and dimensioned so that all static and dynamic forces
can be absorbed and that the riser pipe cannot slip downwards.
The supporting clamps or flanges must be fastened at the well
head so that they cannot shift of lift off the well head.
The unit must never be installed with its suction strainer exactly
at the level of the well screen / filter! Excessive flow in the area
of the well screen / filter entails the risk of large amounts of
entrained sand clogging the well screen / filter and causing
excessive wear in the pump.
Pump units installed in a pump sump must generally be
equipped with a cooling or suction shroud (fig. 2).

3410:71/2

Fig. 3

Horizontal installation (in tanks, mine shafts etc.)

1
2
3
4
5

Submersible borehole pump


Water storage tanks (UMA 300D and 14D motors only)
Pedestal
Expansion joint
Check valve
(only if pump unit does not have its own check valve)
6 Dismantling joint
7 Shut-off valve
8 Intake

60 Hz

Submersible Borehole Pumps

Selection for Deep Wells


Pump Selection
The following data are required for a first rough selection of a
submersible borehole pump:
-- Capacity Q in m3/h (l/s)
-- Pressure at well head HA in m
-- Well diameter D in inches or mm
-- Temperature of fluid handled tA in C
-- Pump head HP in m
While Q, HA, D and tA are usually specified by the customer, the
head HP to be developed by the pump needs to be calculated.
There are two typical applications to be considered (see the
drawing on the right):

1.

Pumping into an open overhead tank


HP = HA + Ht + Hv + HS [m]
with ...
HA = Required pressure at well head
Ht = Lowest water level (dynamic water level)
Hv = Head losses in the check valve (see characteristic
curves for different stage numbers for UPA 150S
and above).
HS = Head losses in riser pipe up to well head
(see page 10).
He = Installation depth

2.

Pumping into a closed tank


Hp = HA + Ht + Hv + HS + p [m]
with ...
p = Gauge pressure (also air cushion) in a tank

Example
Given ...
" QA = 120 m3/h,
" HA = 100 m,
" tA = + 15 C,
" 50 Hz,
" 400 V,
" d.o.l. starting,
" well diameter D = 300 mm (12 inches),
" Ht = 33 m,
" He = 60 m
Found ...
1. step: pump type UPA 200B/250C

. (for QA taken from selection chart on page 4)

2. step: pump size UPA 250C - 120

. (for QA taken from selection chart on page 50)

3. step: pump set UPA 250C-120/3f + UMA 200D 65/21

. (for Hp = HA + Ht + HV + HS = 100 + 33 + 0.5 + 1.5 = 135 m


. with HV taken from characteristic curves for different stage
. numbers on page 61).

. Pump efficiency: P = 81 % (without check valve)


3300:54/3

Figure: Deep well with submersible borehole pump and


overhead tank or closed tank at a pressure above atmospheric
pressure of p.
8

60 Hz
Request for Quotation
We should like to test the efficiency and
quality of your computer-aided quotation
process. Please let us have a quotation
based on the following data. (Fill in the
required data and / or underline the
relevant information, as far as available.)
8

1. Water quality
Temperature . . . . . . . . . . . . . . . . . . . . . C
Sand content . . . . . . . . . . . . . . . . . . g/m3

7
6

Nominal diameter . . . . . . . . . . . . . . . mm

6. Installation depth

He = . . . . . . . . . . . . m

Well depth (distance from ground level to


well base):

Caution: Do not install the submersible


borehole pump at the level of the well
screen / filter!

Inside diameter at submersible pump


installation depth:
D = . . . . . . . . . . . . . . mm ( . . . . inches)

7. Power supply

Well screen / filter:

Single- / three-phase alternating current.


Mains voltage at well:
U= ............................. V

-- Installation depth TF = . . . . . . . . . . . m

Frequency f = . . . . . . . . . . . . . . . . . . Hz

-- Length LF = . . . . . . . . . . . . . . . . . . . m

If voltage drops cannot be precluded:

4. Capacity
Q = . . . . . . . . . . . . . m3/h ( . . . . . . . l/s)

H= ............................ m

3300:54/3

Overall length . . . . . . . . . . . . . . . . . . . . m

3. Deep well

(including all friction losses)

Well screen / filter


Well casing
Submersible borehole pump
Riser
Well head housing
Well head
Power supply cable
Overhead tank

piping outside well head housing:

Ground level to check valve / to


connection branch:

5. Total head

1
2
3
4
5
6
7
8

c)

. . . . . . . . . . . . bar

Discharge into a pressure vessel

TB = . . . . . . . . . . . . . . . . . . . . . . . . . . . . m

p =

Inside diameter reduced by incrustation


to: D = . . . . . . . . . . . . . . . . . . . . . . . . mm

Cut-out pressure in the pressure vessel:

2. Type of system

Discharge into an overhead tank

H = . . . . . . . . . . . . . m ( . . . . . . . . bar)

Number of bends, valves and fittings:


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pcs

Free discharge above ground

Discharge head required at the end of the


piping:

Please attach water analysis, if available.

Well / Mine shaft / Tank

Submersible Borehole Pumps

If H is not known, please provide the


following data:
a) Water level in well, measured from
ground level:
-- Static water level: Hh = . . . . . . . . . . m
-- Dynamic water level: Ht = . . . . . . . . m
(at capacity Q = . . . . . . . . . . . . . . m3/h)
b) Head above ground:
Geodetic altitude up to the highest point
of the pipeline or up to the highest water
level in the overhead tank:

Minimum voltage ...


Umin = . . . . . . . . . . . V

8. Control box
Manual start-up / remote control /
automatic start-up by way of float switch,
pressure switch or dry running protection
equipment.
Other types of switchgear: . . . . . . . . . . .
...................................

9. Starting method
D.o.l. (without / with autotransformer or
soft starter) or star-delta starting.

Hd = . . . . . . . . . . . . . . . . . . . . . . . . . . . m

60 Hz

Submersible Borehole Pumps

Head Losses in the Piping

HV
ft/100 ft

HV
m/100 m

3300:103/3-2

The friction losses given in the above chart roughly apply to new
cast iron pipes. For new rolled steel or plastic pipes, multiply the
values by approx. 0.8. For old, slightly rusty cast iron pipes,
multiply by approx. 1.25. In pipes with incrustations, friction
losses may rise to 1.7 times the value given in the chart for the
10

diameter reduced by incrustations. For pipes subject to considerable incrustation, the friction losses can only be determined experimentally.
Example: Q = 140 m3/h, new DN 150 cast iron pipe.
HV = 3.25 m per 100 m of pipe, v = 2.2 m/sec.

60 Hz
Applications
---------

S 100D
Submersible Borehole Pumps

Domestic and general water supply


Irrigation and spray irrigation
Lowering groundwater levels
Fountains
Pressure boosting
Air-conditioning systems
Fire protection
Cooling water cycles

for Well Diameters


of 100 mm (4 inches) and Above

Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 16 m3/h (4 l/s
or up to 60 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 300 m
Temperature of fluid handled . t

up to +30 C
in continuous operation

Power . . . . . . . . . . . . . . . . . . . . . Pn up to 6.4 kW (8.7 hp)

Design
Pump:
Stainless steel and plastic multistage centrifugal pump.
-- Additional bearing depending on the number of stages
-- Pump sizes D1 and D2 with anti-blockage feature. This consists of a hexagonal polyurethane disc mounted to the back
of the diffuser. A PE-HD ring fitted to the impeller front side
sits close to the disc. The impeller hub is protected by a
polyurethane ring.This design improves the starting torque of
low-capacity pumps and has the effect that solid particles such
as sand are propelled outside instead of clogging the pump.
Motor:
Submersible canned motor (Franklin), NEMA standard, 60 Hz
-- For three--phase current
-- With motor lead
-- Connection to power supply mains by means of cable connector (accessories)
-- D.o.l., start-up frequency up to 20 / h
-- Type of enclosure IP 68
-- Thermal class B

Designation
S 100 D -- 4 / 6
Type series
Well diameter (mm)
Design status
Capacity (m3/h)
Number of stages

Certification
Quality management certified to ISO 9001

Product Features
-----------

Pumps sizes D1 and D2 with anti-blockage feature


Rust-proof
Suitable for installation in narrow deep wells
High efficiency
Hermetically sealed motor
Motor designed for maximum pump output
Low noise level
For vertical, angled or horizontal installation
Check valve with anti-blockage valve disc
Easy dismantling of check valve

11

60 Hz

S 100D

Selection Chart (Ranges on Offer)

n 3450 rpm

S 100D 2

S 100D 1

S 100D 4
S 100D 7

12

S 100D 12

60 Hz
Materials

Drive

Component

Execution C1

Pump ...
Outer pump casing /
Suction casing /
Valve housing

CrNi steel (1.4301)

Stage casing

CrNi steel (1.4301)

Stage casing (diffuser) /


Impeller

S 100D

glass fibre reinforced Noryl


(PPO)

Shaft

Cr steel (1.4021)

Bearing bush

Nitril NBR 80

Screws, bolts and nuts

CrNiMo steel (A4--70)

Motor ...

Type . . . . . . . . . . . . . . . . . . . . . . . canned motor in squirrelcage design, 2 poles


Connection . . . . . . . . . . . . . . . . . NEMA standard
Type of enclosure . . . . . . . . . . . IP 68
Frequency . . . . . . . . . . . . . . . . . 60 Hz
Type of current . . . . . . . . . . . . . . three-phase (3 )
Rated voltage U . . . . . . . . . . . . . 460 V
Rated power PN . . . . . . . . . . . . . . . . up to 5.5 kW (7.5 hp)
Voltage fluctuations . . . . . . . . . . up to 5 % acc. to VDE
Frequency of starts . . . . . . . . . . up to 20 / h
Min. delay before restarting . . . . 3 min

Shaft

CrNi steel (1.4305)

Bearing carrier

CrNi steel (1.4301)

Connection to Power Supply

Stator case

CrNi steel (1.4301)

All DN 100 motors are factory-equipped as follows:

Bearings / Lubrication
Plain bearings, lubricated by the fluid pumped or by the motor
fill liquid. Depending on the number of stages, an additional intermediate bearing is provided in the pump.
The axial thrust is balanced by a thrust bearing in the motor.
The hydraulic thrust is balanced by the pumps counter thrust
bearing.

Direction of Rotation of the Pump


Clockwise rotation (viewed at the drive shaft end).

Pump End (Discharge Nozzle)


S 100D - 1, 2, 4 + 7:

Internal thread G 11/4 (DN 32).

S 100D - 12:

Internal thread G 2 (DN 50).

Installation
Vertical and, depending on the number of stages, inclined as
well as horizontal installation (see tables on page 15 to 19)

1 x 1.5 m flat cable, quality 4 x 1.5 mm2 (3 phases + 1 earth conductor).


Exception: DN 100 motors with a rating of 5.5 kW, 3~, are
equipped as follows: 1 x 2.5 m cable, quality 4 x 1.5 mm2.
Connection of extension cable (any length) by means of a cable
connector:
Connected at the factory by means of a standard cable connector (non-separable, shrink tube)
-- Ident No. 40 980 708
For cable quality 4 x 1.5 mm2 or 4 x 2.5 mm2
-- Ident No. 39 020 536
For cable quality 4 x 4 mm2
Connected at the factory with Franklin cable connector
(separable, sealing compound)
-- Ident No. 90 049 385
For cable quality 4 x 1.5 mm2 up to 4 x 2.5 mm2

Starting Mode
Only direct on line.

Temperatures
The S 100D submersible borehole pump is designed for use in
water with temperatures of up to t = + 30 oC.

13

60 Hz

S 100D

Design Features (Pump sizes D1 -- D2)


Stainless steel valve housing

Non-return valve with


double-guided valve disc
-- No jamming or tilting.
-- If not required, the non-return valve
may be removed.
Diffusers with smooth surfaces
-- Made of glass fibre reinforced
Noryl.

Pump bearing with grooves


-- Maintenance-free and highly
wear-resistant.
-- For smooth long-term operation.

Stainless steel cable guard


-- Easy assembly and dismantling.
-- Protects the power supply cable
against damage.

High-performance impellers
-- Made of glass fibre reinforced
Noryl, highly abrasion- and
corrosion-resistant.
-- With integrated keys for easy
assembly.

State-of-the-art sintered metal


coupling
-- For optimum power transmission.

Stainless steel stage casing


without return vanes
-- High pressure resistance.
-- Easy assembly and dismantling.

Anti-blockage feature with


self-lubricating reinforcing rings
with good anti-seizure properties
and high abrasion resistance.
-- Ensures smooth operation in water
with a low sand content.
-- Suitable for the low starting torque
of pump sizes D1 and D2 for small
capacities.

Stainless steel suction casing

Franklin submersible motor


-- Designed for max. pump power to
protect unit from overloads.
-- Easy-to-fit plug-and-socket
connection of power supply cable.

14

60 Hz

S 100D

S 100D -- 1
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC
-- Current / Operating voltage . . . . . . 3 /460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated
power

Rated
power

(motor)

(motor)

Pump unit

S 100D

PN
kW

PN
hp

IN
A

1
1
1
1
1
1
1
1
1

0.59
0.83
0.83
1.0
1.0
1.4
1.8
1.8
1.8

0.80
1.13
1.13
1.36
1.36
1.90
2.45
2.45
2.45

1.5
2.1
2.1
2.4
2.4
3.1
4.1
4.1
4.1

1)

/ 7
/ 9
/ 12
/ 14
/ 16
/ 20
/ 25
/ 30
/ 35

Current
intensity for
3
460 V

Tolerances to
ISO 9906 Class 2
Annex A

Installation 1)

v+h
v+h
v+h
v+h
v+h
v+h
v
v
v

v = vertical, h = inclined / horizontal.

Note: Use a cooling shroud for horizontal installation.

Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers / Horizontal Installation


Pump unit
S 100D

LA
mm

mA
kg

1/ 7
1/ 9
1 / 12
1 / 14
1 / 16
1 / 20
1 / 25
1 / 30
1 / 35

546
619
686
760
805
923
1064
1176
1366

10.7
11.8
12.2
13.6
13.8
15.7
17.5
18.0
20.0

3 / 460 V
Ident. No.

39 022 613
39 022 614
39 020 615
39 022 616
39 022 617
39 022 618
39 022 619
39 022 620
39 300 025

A
mm

410
450
530
590
630
720
----- -----

G 11/4

For information on cooling shroud refer to page 20.

15

60 Hz

S 100D

S 100D -- 2
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC
-- Current / Operating voltage . . . . . . 3 /460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Current
Installation 1)
intensity for
3
460 V

Rated
power

Rated
power

(motor)

(motor)

Pump unit
S 100D

PN
kW

PN
hp

IN
A

2
2
2
2
2
2
2
2
2

1.00
1.40
1.80
2.50
2.50
2.50
3.40
3.40
4.20

1.36
1.90
2.45
3.40
3.40
3.40
4.62
4.62
5.71

3.4
4.3
5.6
8.6
8.6
8.6
10.6
10.6
15.5

1)

/ 7
/ 11
/ 15
/ 18
/ 20
/ 22
/ 27
/ 30
/ 33

Tolerances to
ISO 9906 Class 2
Annex A

v+h
v+h
v+h
v+h
v+h
v+h
v
v
v

v = vertical and h = inclined / horizontal

Note: Use a cooling shroud for horizontal installation.

Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers / Horizontal Installation


Pump unit
S 100D
2/ 7
2 /11
2 /15
2 /18
2 /20
2 /22
2 /27
2 /30
2 /33

LA
mm
594
721
839
935
980
1048
1205
1272
1506

mA
kg
12.6
14.4
16.0
17.7
17.8
18.1
21.5
21.9
28.3

For information on cooling shroud refer to page 20.

16

3 / 460 V
Ident-No.

mm

39 022 621
39 022 622
39 022 623
39 022 624
39 022 625
39 022 626
39 022 627
39 022 628
39 022 629

410
530
630
750
750
750
----- -----

G 11/4

60 Hz

S 100D

S 100D -- 4
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC
-- Current / Operating voltage . . . . . . 3 /460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated
power

(motor)

(motor)

Pump unit
S 100D

PN
kW

PN
hp

IN
A

4
4
4
4
4
4
4

1.00
1.80
2.50
2.50
4.20
4.20
4.20

1.36
2.45
3.40
3.40
5.71
5.71
5.71

2.4
4.1
5.6
5.6
8.7
8.7
8.7

1)

21

Tolerances to
ISO 9906 Class 2
Annex A

16

Current
Installation 1)
intensity for
3
460 V

Rated
power

/ 3
/ 6
/ 8
/ 11
/ 16
/ 21
/ 24

24

11
8

v+h
v+h
v+h
v+h
v+h
v+h
v

v = vertical, h = inclined / horizontal.

Note: Use a cooling shroud for horizontal installation.

Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers / Horizontal Installation


Pump unit
S 100D

LA
mm

mA
kg

4/ 3
4/ 6
4/ 8
4 /11
4 /16
4 /21
4 /24

556
663
768
845
1160
1287
1364

12.8
16.0
17.7
18.2
28.4
29.5
30.0

3 / 460 V
Ident. No.

39 022 630
39 022 631
39 022 632
39 022 633
39 022 634
39 022 635
39 022 636

A
mm

410
450
530
630
875
990
--------

G 11/4

For information on cooling shroud refer to page 20.

17

60 Hz

S 100D

S 100D -- 7
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC
-- Current / Operating voltage . . . . . . 3 /460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Current
Installation 1)
intensity for
3
460 V

Rated
power

Rated
power

(motor)

(motor)

Pump unit
S 100D

PN
kW

PN
hp

IN
A

7
7
7
7
7
7

1.80
2.50
3.40
4.20
4.20
6.40

2.45
3.40
4.62
5.71
5.71
8.70

4.1
5.6
7.4
8.7
8.7
13.1

1)

/ 4
/ 6
/ 8
/ 11
/ 13
/ 18

18

Tolerances to
ISO 9906 Class 2
Annex A

13
11

v+h
v+h
v+h
v+h
v+h
v

v = vertical, h = inclined / horizontal.

Note: Use a cooling shroud for horizontal installation.

Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers / Horizontal Installation


Pump unit
S 100D
7/ 4
7/ 6
7/ 8
7 /11
7 /13
7 /18

LA
mm
671
768
903
1127
1195
1518

mA
kg
15.8
17.7
21.1
27.8
28.3
35.9

For information on cooling shroud refer to page 20.

18

3 / 460 V
Ident. No.

mm

39 022 637
39 022 638
39 022 639
39 022 640
39 022 641
39 022 642

450
530
650
875
960
-- --

G 11/4

60 Hz

S 100D

S 100D -- 12
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC
-- Current / Operating voltage . . . . . . 3 /460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
RatedRatedCurrent
Installation 1)
power
power intensity for
(motor)
(motor)
3
460 V
Pump unit
S 100D

PN
kW

PN
hp

IN
A

12
12
12
12

1.80
3.40
4.20
6.40

2.45
4.62
5.71
8.70

4.1
7.4
8.7
13.1

1)

/ 4
/ 6
/ 10
/ 13

Tolerances to
ISO 9906 Class 2
Annex A

v+h
v+h
v
v

v = vertical, h = inclined / horizontal.

Note: Use a cooling shroud for horizontal installation.

Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers / Horizontal Installation


Pump unit
S 100D
12 / 4
12 / 6
12 /10
12 /13

LA
mm
835
1039
1378
1694

mA
kg
15.9
21.3
28.3
37.0

3 / 460 V
Ident. No.

mm

39 022 643
39 022 644
39 022 645
39 022 646

630
750
----- --

G 2

For information on cooling shroud refer to page 20.

19

60 Hz

S 100D

Permissible Cable Lengths


U up to 3 %, direct starting and t up to + 30 oC
Current /
Voltage

3/
460 V

Motor
rating

Motor
rating

Cable lengths for


cable cross-section in ... mm2

kW

hp

1.5

2.5

4.0

6.0

1.0
1.4
1.8
3.2
3.4
4.2
6.4

1.36
1.90
2.45
4.35
4.62
5.71
8.70

352 m
262 m
203 m
154 m
118 m
97 m
62 m

587 m
437 m
339 m
258 m
197 m
161 m
104 m

---700 m
542 m
413 m
316 m
259 m
167 m

---------619 m
474 m
388 m
251 m

Technical Data - Cooling Shroud


Pump unit
S 100D

Installation 1)

1/7 to 1/16
2/7
4/3

Dimensions (dia. x length)


and motor type (kW)

Cooling Shroud
Ident. No.

v+h
v+h
v+h

115 (130) x 400


up to 1.0 kW (3~)
Weight 1.5 kg

90 065 490

1/20 to 1/30
2/11 to 2/15
4/6
7/4
12/4

v
v+h
v+h
v+h
v+h

115 (130) x 500


up to 1.8 kW (3~)
Weight 1.7 kg

90 065 491

2/18 to 2/22
2/27 to 2/30
4/8 to 4/11
7/6 to 7/8
12/6

v+h
v
v+h
v+h
v+h

115 (130) x 625


up to 3.4 kW (3~)
Weight 2.0 kg

90 065 492

2/33
4/16 to 4/21
4/24
7/11 to 7/13
7/18
12/10 to 12/13

v
v+h
v
v+h
v
v

115 (130) x 800


up to 6.4 kW (3~)
Weight 2.5 kg

90 065 493

1)

20

v = vertical, h = inclined / horizontal

Strainer
Ident. No.

Support feet
Ident. No.

90 065 494

90 065 495

115x117
Weight 0.3 kg

Set = 2 pc.
Weight 0.6 kg

60 Hz
Applications
---------

UPA 100C
Submersible Borehole Pumps

Domestic and general water supply


Irrigation and spray irrigation
Groundwater lowering
Fountains
Pressure boosting
Air-conditioning systems
Fire protection
Cooling water cycles

of Stainless Steel
for Well Diameters
of 100 mm (4 inches) and Above

Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 18 m3/h (5 l/s
or up to 80 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 450 m
Temperature of fluid handled . . t

up to +30 C

Motor ratings . . . . . . . . . . . . . . . PN up to 7.5 kW (10 hp)


Maximum permissible
amount of suspended sand: . . 50 g/m3

Design
Multistage centrifugal pump with components made of stainless steel and additional bearing for each stage.
Submersible canned motor: Franklin Electric pre-filled motors, corrosion free, NEMA shaft end, 60 Hz
-- three-phase motor type Super Stainless
-- with separate lead
-- direct start, max starts : 20 / h
-- Type of enclosure: IP 68
-- Insulation: Class B

Designation
Type series
Minimum well diameter (mm)
Design status
Capacity Qopt (US GPM)
Number of stages

Certification

UPA 100 C 10 -- 6

Quality management certified to ISO 9001

Product Features
-----------

Very sturdy design


All components made of stainless steel
Suitable for installation in narrow deep wells
High efficiency
Totally enclosed motor
Motor designed for maximum pump output
Low noise level
For vertical or horizontal installation
Non-return valve protected against blocking
Pre-filled motor without risk of contamination of the pumped
water

21

60 Hz
Selection Chart (Ranges on

UPA 100C
n 3500 rpm

Offer)

UPA 100C 16

UPA 100C 10
UPA 100C 22
UPA 100C 35

UPA 100C 60

UPA 100C 22
UPA 100C 16

UPA 100C 35

UPA 100C 10
UPA 100C 60

Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this range. The operating
ranges QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages.
22

60 Hz
Materials

UPA 100C

Drive

Components

Execution C1

Pump ...

Type . . . . . . . . . . . . . . . . . . . submersible canned motor


Connection . . . . . . . . . . . . . NEMA standard
Type of enclosure . . . . . . . . IP 68

Diffuser,
upper diffuser,
lower diffuser,
Impeller,
Pump shaft with NEMA
coupling,
Suction casing,
suction filter,
Discharge casing,
Spacer sleeve,
Hook

stainless steel AISI 304

Seal ring

NBR + AISI 316

Upper bearing bush

NBR + AISI 316

Starting Mode

Intermediate bearing bush

NBR

Direct on line.

Valve face

NBR + AISI 316

Frequency . . . . . . . . . . . . . . 60 Hz
Type of current . . . . . . . . . . three-phase
Rated voltage U . . . . . . . . . 3~ 460 V
Rated power PN . . . . . . . . . up to 7.5 kW (10 hp)
Voltage fluctuations . . . . . . up to +/-- 10 %
Start-up frequency . . . . . . . up to 20 / h
Min. standstill time . . . . . . . 3 min

Motor ...
Shaft

stainless steel AISI 304 SS

Bearing housing

stainless steel AISI 304 SS

Stator case

stainless steel AISI 304 SS

Temperatures
The UPA 100 C submersible borehole pump is designed for use
in water with temperatures of up to +30 C.

Permissible Cable Lengths


Direction of Rotation of the Pump

U up to 3 %, d.o.l starting and t up to +30 C.


Current /
Voltage

Clockwise rotation (viewed at the drive shaft end).

Pump End (Discharge Nozzle)


UPA 100C

10 -- 16 -- 22:

Rp 11/2

35 -- 60

Rp 2
3~ /
460V

Installation
Vertical or horizontal installation without restriction.
In order to guarantee the dissipation of the motor driving heating. It will be necessary to install a device guiding the flow along
the motor (cooling shroud, flow inducer sleeve, etc.) in horizontal installation.

Motorrating
kW

Motorrating
hp

0.75
1.10
1.50

Cable lengths for


cable cross-section in ... mm2
1.5

2.5

4.0

6.0

1.02
1.50
2.04

352 m
262 m
203 m

587 m
437 m
339 m

-700 m
542 m

----

2.20
3.00
3.70
4.00

3.00
4.08
5.03
5.44

154 m
118 m
97 m
84 m

258 m
197 m
161 m
140 m

413 m
316 m
259 m
224 m

619 m
474 m
388 m
336 m

5.50
7.50

7.48
10.2

62 m
48 m

104 m
80 m

167 m
128 m

251 m
192 m

Variants Available on Request


----

Higher medium temperatures


Voltages above 500 V
Other frequencies

23

60 Hz

UPA 100C

Design Features

Optimised operating costs:


Check valve, built into the discharge chamber, designed for low
loss of head.

Resistance to corrosion and abrasion, i.e. the same inherent qualities


of stainless steel.

Hydraulic profiles are optimized for


the attainment of high efficiencies.

Oversized intermediate bearings


located at each pump stage to
align the shaft, specially designed
to optimize lubrication.

Coupling and flange suitable


for motors with pump mounting dimensions in accordance with NEMA standards.

24

Reliable in service:
Very strong construction: minimum
thickness of stainless sheet steel of
1 mm, 6 spot welding on each vane,
special top bearing for every pump.

Friendly service:
Great ease of dismantling and assembly.
Easy-to-replace wear-rings and
bearings.

60 Hz

UPA 100C

UPA 100C 10 -- ...


D1

UPA 100C 10 -- ...

62

(Tolerances to ISO 2548


Class C, Annex B)

54

(3.86 inch)

48

41

34

27
21

(3.75 inch)
D1 max:
Pump = 96.5 mm
Pump with motor
= 98.0 mm

15
12
9

Rated
power
(Motor)

Rated
power
(Motor)

Pump unit
UPA 100C 10 --..

PN
kW

PN
hp

Rated current
for
3~
460 V
IN 1)
A

6
9
12
15
21

0.37
0.37
0.55
0.75
1.1

0.50
0.50
0.75
1.00
1.50

1.5
1.5
2.1
2.4
3.1

27
1.5
2.00
4.1
34
2.2
3.00
5.6
41
3.7
5.00
8.7
48
3.7
5.00
8.7
54
3.7
5.00
8.7
62
3.7
5.00
8.7
1) Capacitor run motors (PSC motors) with starter.

Capacity
m3/h

Operating range: 1.1 -- 3.2


(5.0 -- 14.0 US GPM)
Qmin = 1.1 m3/h (5.0 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers


3~ / 460 V
Pump unit
UPA 100C 10 --..
6
9
12
15
21
27
34
41
48
54
62

A inches

A mm

B inches

B mm

C inches

C mm

Ident. No.

mA kg

13.74
16.57
19.45
22.28
27.99
34.09
40.31
46.97
53.62
63.11
65.98

349
421
494
566
711
866
1024
1193
1362
1603
1676

9.53
9.53
10.66
11.75
11.75
13.62
16.06
22.20
22.20
22.20
22.20

242
242
271
298
298
346
408
564
564
564
564

23.27
26.10
30.11
34.03
39.74
47.74
56.37
69.17
75.82
80.54
85.30

591
663
765
864
1009
1212
1432
1747
1926
2046
2167

90 065 337
90 065 338
90 065 339
90 065 340
90 065 341
90 065 342
90 065 343
90 065 344
90 065 345
90 065 346
90 065 347

12.1
13.2
15.6
18.1
20.1
24.0
29.7
41.2
43.8
45.1
49.1

For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.

25

60 Hz

UPA 100C

UPA 100C 16 -- ...


D1

UPA 100C 16 -- ...

62

(Tolerances to ISO 2548


Class C, Annex B)

(3.86 inch)

51

41

31
24

(3.75 inch)
D1 max:

18

Pump = 96.5 mm
Pump with motor
= 98.0 mm

14
10

Pump unit
UPA 100C 16 --..

Rated
power
(Motor)

Rated
power
(Motor)

PN
kW

PN
hp

Rated current
for
3~
460 V
IN 1)
A

5
0.37
0.50
1.5
8
0.55
0.75
2.1
10
0.75
1.00
2.4
14
1.10
1.50
3.1
18
1.50
2.00
4.1
24
2.20
3.00
5.6
31
3.70
5.00
8.7
41
3.70
5.00
8.7
51
5.50
7.50
13.1
62
5.50
7.50
13.1
1) Capacitor run motors (PSC motors) with starter.

Capacity
m3/h

Operating range: 2.2 -- 4.5


(10 -- 20 US GPM)
Qmin = 2.2 m3/h (10 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers


3~ / 460 V
Pump unit
UPA 100C 16 --..
5
8
10
14
18
24
31
41
51
62

A inches

A mm

B inches

B mm

C inches

C mm

Ident. No.

mA kg

12.79
15.63
16.81
21.34
25.12
30.83
37.48
46.97
55.50
65.98

325
397
427
542
638
783
952
1193
1410
1676

9.53
10.66
11.75
11.75
13.62
16.06
22.20
22.20
28.20
28.20

242
271
298
298
346
408
564
564
716
716

18.32
26.29
28.56
33.09
38.74
46.89
59.68
69.17
83.69
94.16

567
668
725
840
984
1191
1516
1757
2126
2392

90 065 348
90 065 349
90 065 350
90 065 351
90 065 352
90 065 353
90 065 354
90 065 355
90 065 356
90 065 357

11.7
14.2
16.2
17.6
20.9
26.1
37.7
41.2
50.4
54.0

For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.

26

60 Hz

UPA 100C

UPA 100C 22 -- ...


D1

UPA 100C 22 -- ...


(Tolerances to ISO 2548
Class C, Annex B)

60
(3.86 inch)

47

39

31
26
(3.75 inch)
D1 max:

19

Pump = 96,5 mm
Pump with motor
= 98,0 mm

Pump unit
UPA 100C 22 --..

Rated
power
(Motor)

Rated
power
(Motor)

PN
kW

PN
hp

13
7

Rated current
for
3~
460 V
IN 1)
A

10
6

4
0.37
0.50
1.5
6
0.55
0.75
2.1
7
0.75
1.00
2.4
10
1.10
1.50
3.1
13
1.50
2.00
4.1
19
2.20
3.00
5.6
26
3.70
5.00
8.7
31
3.70
5.00
8.7
39
5.50
7.50
13.1
47
5.50
7.50
13.1
60
7.50
10.0
17.0
1) Capacitor run motors (PSC motors) with starter.

Capacity
Operating range: 2.2 -- 6.8 m3/h (10 -- 30 US GPM)
Qmin = 2.2 m3/h (10 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers


3~ / 460 V
Pump unit
UPA 100C 22 --..
4
6
7
10
13
19
26
31
39
47
60

A inches

A mm

B inches

B mm

C inches

C mm

Ident. No.

mA kg

11.85
13.74
14.68
16.81
20.39
26.06
32.72
37.48
45.08
52.68
64.10

301
349
373
427
518
662
831
952
1145
1338
1628

9.53
10.66
11.75
11.75
13.62
16.06
22.20
22.20
28.20
28.20
30.47

242
271
298
298
346
408
564
564
716
716
774

21.37
24.40
26.43
28.56
34.01
42.12
54.92
59.68
73.28
80.88
94.57

543
620
671
725
864
1070
1547
1516
1861
2054
2402

90 065 358
90 065 359
90 065 360
90 065 361
90 065 362
90 065 363
90 065 364
90 065 365
90 065 366
90 065 367
90 065 368

11.4
13.3
15.1
16.4
19.1
28.4
35.9
37.4
47.3
50.2
57.2

For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.

27

60 Hz

UPA 100C

UPA 100C 35 -- ...


D1

UPA 100C 35 -- ...


(Tolerances to ISO 2548
Class C, Annex B)

41

(3.86 inch)

36
31
26

20
16

(3.75 inch)
D1 max:
Pump = 96,5 mm
Pump with motor
= 98,0 mm

12
9
5

Rated
power
(Motor)

Rated
power
(Motor)

Pump unit
UPA 100C 35 --..

PN
kW

PN
hp

Rated current
for
3~
460 V
IN 1)
A

2
4
5
7
9

0.37
0.55
0.75
1.10
1.50

0.50
0.75
1.00
1.50
2.00

1.5
2.1
2.4
3.1
4.1

12
16
20
26
31

2.20
3.70
3.70
5.50
5.50

3.00
5.00
5.00
7.50
7.50

5.6
7.4
7.4
13.1
13.1

7
4

Capacity

36
7.50
10.0
17.0
41
7.50
10.0
17.0
1) Capacitor run motors (PSC motors) with starter.

Operating range: 3.3 -- 10 m3/h (15--45 US GPM)


Qmin = 3.3 m3/h (15 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers


3~ / 460 V
Pump unit
UPA 100C 35 --..
2
4
5
7
9
12
16
20
26
31
36
41

A inches

A mm

B inches

B mm

C inches

C mm

Ident. No.

mA kg

9.96
11.85
12.80
14.68
15.87
19.45
23.23
27.00
32.72
37.48
42.20
46.97

253
301
325
373
403
494
590
686
831
952
1072
1193

9.53
10.66
11.75
11.75
13.62
16.06
22.20
22.20
28.20
28.20
43.90
43.90

242
271
298
298
346
408
564
564
716
716
1115
1115

19.49
22.51
24.55
26.43
27.49
35.51
45.43
49.20
60.92
65.68
86.10
90.87

495
572
623
671
698
902
1154
1250
1547
1668
2187
2054

90 065 369
90 065 370
90 065 371
90 065 372
90 065 373
90 065 374
90 065 375
90 065 376
90 065 377
90 065 378
90 065 379
90 065 380

10.8
12.7
14.4
15.1
17.6
21.7
32.4
33.3
42.7
44.4
48.5
50.3

For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.

28

60 Hz

UPA 100C

UPA 100C 60 -- ...


D1

UPA 100C 60 -- ...


(Tolerances to ISO 2548
Class C, Annex B)

(3.86 inch)

18

13

9
(3.75 inch)

D1 max:
Pump = 96,5 mm
Pump with motor
= 98,0 mm

5
4

Rated
power
(Motor)

Rated
power
(Motor)

Pump unit
UPA 100C 60 --..

PN
kW

PN
hp

Rated current
for
3
3~
460 V
IN 1)
A

4
5
7
9
13
18

1.50
2.20
3.70
3.70
5.50
7.50

2.00
3.00
5.00
5.00
7.50
10.0

4.1
5.6
8.7
8.7
13.1
17.0

1)

Capacitor run motors (PSC motors) with starter.

Capacity

Operating range: 5.5 -- 18.0 m3/h (25--80 US GPM)


Qmin = 5.5 m3/h (25 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.

Dimensions / Weights / Ident. Numbers


3~ / 460 V
Pump unit
UPA 100C 60 --..
4
5
7
9
13
18

A inches

A mm

B inches

B mm

C inches

C mm

Ident. No.

mA kg

14.45
15.94
19.02
22.00
28.11
35.71

367
405
483
559
714
907

13.62
16.06
22.20
22.20
28.20
43.90

346
408
564
564
716
1115

28.07
32.01
41.22
44.21
56.30
79.62

713
813
1047
1123
1430
2022

90 065 381
90 065 382
90 065 383
90 065 384
90 065 385
90 065 386

16.2
19.8
29.7
30.5
39.5
43.4

For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.

29

60 Hz

30

UPA 100C

60 Hz
Applications

UPA 150C
Submersible Borehole Pumps

Suitable for handling clean or slightly contaminated water


in applications such as:
-- domestic water supply

for Well Diameters of


150 mm (6 inches)

-- general water supply


-- irrigation and spray irrigation systems
-- artificial lowering of the ground water level as well as
-- heat transfer plants
In addition, the pump sets are used in pressure
boosting systems, air-conditioning systems, fountains, etc.
Permissible sand content in the fluid handled: 50 g/m3.

Operating Data
Capacity . . . . . . . . . . . . . . . . . .
Head . . . . . . . . . . . . . . . . . . . . .
Temperature of fluid handled .
Speed . . . . . . . . . . . . . . . . . . . .

Q
H
t
n

up to 93 m3/h (26 l/s)


up to 730 m
up to 50 C
3500 rpm

Design
Multistage centrifugal pump with components made of
stainless steel and additional bearing for each stage. The stage
casings are connected by means of tie bolts.
Motor
Canned or wet submersible squirrel-cage motor, 2 poles;
NEMA shaft end; 60 Hz; type of enclosure: IP 68

Designation (Example)
UPA 150 C -- 16 / 9
Type series
Minimum well diameter (mm)
Design status
Capacity (m3/h)
Number of stages

Certification
Quality management certified to ISO 9001

Product Features
-- Rust-proof
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical, angled or horizontal installation
-- Check valve with anti-blockage valve disc

31

60 Hz

UPA 150C

Selection Charts (Ranges on Offer)

n 3500 rpm

UPA 150C -- 60
UPA 150C -- 16

UPA 150C -- 30

UPA 150C -- 48

UPA 150C -- 16

UPA 150C -- 30

32

UPA 150C -- 48

UPA 150C -- 60

60 Hz
Material Variants

Bearings / Lubrication
Material

Component

UPA 150C

C1 (AISI 304)

C2 (AISI 316)

Radial plain bearings: pump bearings lubricated by the fluid


handled, motor bearings by the motors water fill. Axial thrust is
balanced by a tilting-pad thrust bearing in the motor (lower end).

Pump
Suction casing

Direction of Rotation of the Pump

1.4408

Stage casing

1.4301

1.4404

Stage casing with hole

1.4301

1.4404

Upper stage casing

1.4301

1.4404

Suction strainer

1.4401

1.4404

Flanged end piece

1.4408

Shaft

1.4305

1.4401

Impeller

1.4301

1.4404

Thrust bearing

HY22

Counter thrust bearing

A2

A4

O-ring

NBR

Casing wear ring

NBR

Impeller wear ring

1.4301

1.4404

Bearing bush

NBR

Disc

1.4301

1.4404

Valve body

1.4408

Valve spring

1.4401

Valve plate

1.4404

Coupling

1.4308

1.4408

Tiebolt

1.4301

1.4404

Hexagon socket head screw

A2

A4

Hexagon socket head screw

A4

A4

Nut

A2

A4

Impeller nut

1.4401

Locking sleeve

1.4401

Clamp

1.4301

1.4404

Cable support

1.4301

1.4404

Protection plug

HY22
Material

C
Component
t

C1 (AISI 304)

C2 (AISI 316)

1.4305

1.4462

1.4301

1.4401

JL--1030

1.4409

1.4301

1.4571

Motor
Shaft
Bearing carrier
Stator case

DN 100
UMA 150D

Description
1.4301
1.4305
1.4308
1.4401
1.4404
1.4408
1.4462
1.4571
JL -- 1030
A2
A4
HY22
NBR

CrNi steel
CrNi steel
CrNi steel
CrNiMo steel
CrNiMo steel
CrNiMo steel
CrNiMo steel
CrNiMo steel
cast iron
CrNi steel
CrNiMo steel
Carbon/graphite in PTFE
Acrylnitril--Butadien--Kautschuk

Clockwise rotation (when looking at the drive shaft end).

Pump End (Discharge)


UPA 150C submersible borehole pumps can be supplied with
the following discharge ends:
G 21/2 G 3 G 4 DN 50 DN 65 DN 80
UPA 150C -- 16

--

UPA 150C -- 30

--

--

UPA 150C -- 48

--

--

UPA 150C -- 60

--

--

Coating (Bearing carrier)


UMA 150D motor:
Quality . . . . . . . . . . . powder coating, approved for
drinking water contact

Type of Installation
Standard vertical installation. Depending on the number of
stages, horizontal installation is also possible.
Motor DN 100: In order to guarantee the dissipation of the
motor heat it will be necessary to install a device guiding the flow
along the motor (cooling jacket, flow inducer sleeve, etc.) in
horizontal installation.

Drive
Design . . . . . . . . . . . . . . Canned 1) or wet 2) submersible
squirrel-cage motor, 2 poles
Connection . . . . . . . . . . NEMA standard
Type of enclosure . . . . IP 68
Frequency f . . . . . . . . . . 60 Hz
Type of current . . . . . . . three-phase (3 ~)
Rated voltage U . . . . . . up to 460V
Rated power PN . . . . . . . . up to 44 kW
Frequency of starts . . . 20 / h 1) and 15 / h 2)
Minimum delay
before restarting . . . . . . 1 min 1) or 2 min 2)
Motor design is in compliance with VDE regulations.
1)

Motor DN 100

2)

Motor UMA 150D

Connection to Power Supply


The submersible motors are supplied ex factory with 1 or 2
motor leads, each equipped with an earth conductor. All motors
are provided with internal earthing. Any extension cables
required are connected using water-tight cable connectors.
Motor leads and extension cables are suitable for drinking
water applications.

33

60 Hz
Starting
Motor DN 100 . . . . . d.o.l. only
(autotransformer or soft starter)
Motor UMA 150D . . d.o.l. (autotransformer or soft starter)
or star-delta

Variable Speed
The submersible borehole pumps can also be equipped with a
speed control system to accommodate different operating
points.

Application Temperatures
The submersible borehole pumps are, as a standard, suitable
for use in water with temperatures of up to t = + 30 C. An
indispensable requirement for this is a flow velocity of
v = 0.5 m/s past the motor. This requirement is met, for example,
when the pump is installed in a deep well above the well screen
/ filter, etc.
With certain restrictions, some motor sizes may also be used in
water with temperatures of up to t = + 50 C or for operation
without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).

Variants Available on Request


-- Other supply voltages up to 1000 V
-- Models with cooling, suction or pressure shroud

34

UPA 150C

60 Hz

UPA 150C

Design Features of the pump

Corrosion resistance
The pump and motor are constructed
of high--grade stainless steel as
standard -- producing consistently
high efficiency levels. Also available
in higher grade CrNiMo steel for
aggressive fluids.

Low operating costs


High efficiency and low--loss check
valve maintain long--term energy
savings over the entire service lifetime of the unit.

Maintenance--friendly design
D Simple disassembly and reassembly
D Rewindable motors

Flexibility
D Exchangeable connection variants
D Check valve can be removed easily
D Suitable for vertical installation in
deep wells or horizontal installation
D NEMA connection

High operating reliability and


long service life
Equipped with reinforced suction
strainer, robust drive lantern and
check valve made of investment
cast stainless steel. Laser--welded
impellers.
Protected against thrust reversal.

Hygienic and approved


for drinking water
ACS approved

35

60 Hz

UPA 150C

Design Features of the motor UMA 150D

The KSB motor


-- VDE-compliant, i.e., high level of
electrical safety.
-- Designed for max. pump power
to protect unit from overloads.

Dynamically balanced rotor


-- Ensures smooth running.
Counter thrust bearing
-- Reliable balancing of negative axial
thrust.
-- Impellers do not rub on the stage
casings.

Tried and tested thrust bearing


-- Water-lubricated self-aligning
tilting-pad journal bearing.
-- No-maintenance design suitable for
maximum load-carrying capacity
under continuous operation
conditions.
-- New materials combination (stainless
steel / carbon) for high safety factor.

36

60 Hz

UPA 150C

37

60 Hz

UPA 150C -- 16 / ...; number of stages 1 -- 15


The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv :

Head losses in the check


valve

p:

Pump efficiency (not


considering check valve)
NPSH: Net positive suction head
required by the pump

Pump End G 21/2


The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall
length (mm)

Dmax
(mm)

G 21/2

40

G 3

48

G 4

93

DN 50

77

165

DN 65

77

185

DN 80

77

200

see
page 41

Threaded end to DIN ISO 228, Part 1.


Flange end to DIN 2501, Part 1

G 21/2

Dmax

Lp

LA

38

UPA 150C

60 Hz

UPA 150C

UPA 150C -- 16 / ...; number of stages 16 -- 45


The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv :

Head losses in the check


valve

p:

Pump efficiency (not


considering check valve)
NPSH: Net positive suction head
required by the pump

Pump End G 21/2


The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall
length (mm)

Dmax
(mm)

G 21/2

40

G 3

48

G 4

93

DN 50

77

165

DN 65

77

185

DN 80

77

200

see
page 41

Threaded end to DIN ISO 228, Part 1.


Flange end to DIN 2501, Part 1
G 21/2

Dmax

Lp

LA

39

60 Hz

UPA 150C

Technical Data
Pumps with submersible motors for ...

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature
of the fluid pumped
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section
of conductors (use under
water, 460 V and +30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

d.o.l.
mm2

Y-
mm2

1 + DN 100 - 1.1

15.6

1.3

1.7

30

2.9

74.0

0.77

4 x 1.5

--

2 + DN 100 - 2.2

31

2.5

3.4

30

5.6

77.0

0.77

4 x 1.5

--

3 + DN 100 - 3.0

47

3.4

4.6

30

7.4

79.0

0.76

4 x 1.5

--

4 + DN 100 - 3.7

64

4.2

5.6

30

8.7

78.0

0.79

4 x 1.5

--

5 + UMA 150D 5/21

82

5.5

7.4

42

12.1

75.5

0.79

4 x 2.5

3/4 x 2.5

6 + UMA 150D 5/21

98

6.5

8.7

39

13.6

75.5

0.83

4 x 2.5

3/4 x 2.5

7 + UMA 150D 7/21

115

7.5

10.1

40

15.6

77.5

0.81

4 x 2.5

3/4 x 2.5

8 + UMA 150D 9/21

131

8.5

11.4

40

17.4

79.0

0.80

4 x 2.5

3/4 x 2.5

9 + UMA 150D 9/21

147

9.5

12.7

38

19.0

78.5

0.82

4 x 2.5

3/4 x 2.5

10 + UMA 150D 9/21

162

10.0

13.4

35

19.8

78.5

0.83

4 x 2.5

3/4 x 2.5

11 + UMA 150D 13/21

181

11.5

15.4

41

23.0

82.0

0.77

4 x 2.5

3/4 x 2.5

12 + UMA 150D 13/21

197

12.5

16.8

40

24.5

82.0

0.79

4 x 2.5

3/4 x 2.5

13 + UMA 150D 13/21

212

13.5

18.1

38

26.0

82.0

0.81

4 x 2.5

3/4 x 2.5

14 + UMA 150D 13/21

228

14.5

19.4

37

27.5

81.5

0.82

4 x 2.5

3/4 x 2.5

15 + UMA 150D 13/21

243

15.0

20.1

35

28.5

81.5

0.82

4 x 2.5

3/4 x 2.5

16 + UMA 150D 13/21

258

15.6

20.9

33

29.0

81.5

0.83

4 x 2.5

3/4 x 2.5

17 + UMA 150D 15/21

275

17.0

22.8

35

31.0

82.5

0.84

4 x 4.0

3/4 x 2.5

18 + UMA 150D 15/21

291

18.0

24.1

34

33.0

82.0

0.84

4 x 4.0

3/4 x 2.5

19 + UMA 150D 18/21

310

20.0

26.8

36

37.0

83.0

0.82

4 x 4.0

3/4 x 2.5

20 + UMA 150D 18/21

325

20.0

26.8

34

37.0

83.0

0.82

4 x 4.0

3/4 x 2.5

21 + UMA 150D 18/21

340

21.0

28.2

33

39.0

83.0

0.82

4 x 4.0

3/4 x 2.5

22 + UMA 150D 18/21

356

22.0

29.5

31

40.5

82.5

0.83

4 x 4.0

3/4 x 2.5

23 + UMA 150D 22/21

376

24.0

32.2

37

44.0

84.5

0.81

4 x 4.0

3/4 x 2.5

24 + UMA 150D 22/21

391

25.0

33.5

36

45.5

84.5

0.82

4 x 4.0

3/4 x 2.5

25 + UMA 150D 22/21

406

25.0

33.5

35

45.5

84.5

0.82

4 x 4.0

3/4 x 2.5

26 + UMA 150D 22/21

421

26.0

34.9

34

47.0

84.5

0.83

4 x 4.0

3/4 x 2.5

27 + UMA 150D 22/21

437

26.4

35.4

33

47.5

84.5

0.83

4 x 4.0

3/4 x 2.5

28 + UMA 150D 26/21

457

29.0

38.9

38

52.0

85.5

0.83

4 x 6.0

3/4 x 4.0

29 + UMA 150D 26/21

472

30.0

40.2

37

54.0

85.5

0.83

4 x 6.0

3/4 x 4.0

30 + UMA 150D 26/21

487

30.0

40.2

36

54.0

85.5

0.83

4 x 6.0

3/4 x 4.0

33 + UMA 150D 30/21

540

34.0

45.6

37

62.0

86.0

0.82

4 x 6.0

3/4 x 4.0

36 + UMA 150D 30/21

585

36.0

48.3

35

64.0

85.5

0.83

4 x 6.0

3/4 x 4.0

39 + UMA 150D 37/22

635

40.0

53.6

48

72.0

85.0

0.82

3/4 x 4.0 3)

3/4 x 4.0

42 + UMA 150D 37/22

682

42.0

56.3

46

76.0

85.0

0.83

3/4 x 4.0 3)

3/4 x 4.0

0.84

3)

3/4 x 4.0

UPA 150C -- 16 / ...

45 + UMA 150D 37/22


1) also see page 34

40

727

44.0

59.0

2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.

43
3) Parallel cable

78.0

85.0

3/4 x 4.0

60 Hz

UPA 150C

Dimensions / Weights / Horizontal Installation 1)


UPA 150C -- 16 / ...

LP
mm

LA mm

mA in kg
g

Dmax in mm

Installation 2)3)

C1 (AISI 304)

C2 (AISI 316)

d.o.l.

Y-

337

635

635

17

139

--

v 3)

397

755

755

21

139

--

v 3)

458

880

880

25

139

--

v 3)

518

1075

1075

34

139

--

v 3)

611

1310

1310

62

148

148

v+h

671

1370

1370

63

148

148

v+h

732

1455

1450

66

148

148

v+h

792

1545

1540

71

148

148

v+h

853

1605

1600

72

148

148

v+h

10

913

1665

1660

73

148

148

v+h

11

974

1805

1805

82

148

148

v+h

12

1034

1865

1865

83

148

148

v+h

13

1095

1925

1925

85

148

148

v+h

14

1155

1985

1985

86

148

148

v+h

15

1216

2045

2045

87

148

148

v+h

16

1276

2105

2105

89

148

148

v+h

17

1337

2215

2210

94

148

148

v+h

18

1397

2275

2270

95

148

148

v+h

19

1458

2380

2375

101

148

148

v+h

20

1518

2440

2435

102

148

148

v+h

21

1579

2500

2500

103

148

148

v+h

22

1639

2560

2560

105

148

148

v+h

23

1700

2710

2710

114

148

148

v+h

24

1760

2770

2770

116

148

148

v+h

25

1821

2830

2830

117

148

148

v+h

26

1881

2890

2890

118

148

148

v+h

27

1942

2955

2950

120

148

148

v+h

28

2002

3120

3115

130

149

149

v 3)

29

2063

3180

3175

131

149

149

v 3)

30

2123

3240

3235

133

149

149

v 3)

33
36
39

on request
q

42
45
1) Including check valve with threaded end and standard motor leads.

2) v = vertical / h = horizontal.

3) horizontale installation on request

41

60 Hz

UPA 150C -- 30 / ...; number of stages 1 -- 13


The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv :

Head losses in the check


valve

p:

Pump efficiency (not


considering check valve)
NPSH: Net positive suction head
required by the pump

Pump End G 3
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall
length (mm)

Dmax
(mm)

G 21/2

40

G 3

48

G 4

93

DN 50

77

165

DN 65

77

185

DN 80

77

200

see
page 45

Threaded end to DIN ISO 228, Part 1.


Flange end to DIN 2501, Part 1
G 3

Dmax

Lp

LA

42

UPA 150C

60 Hz

UPA 150C

UPA 150C -- 30 / ...; number of stages 14 -- 23


The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv :

Head losses in the check


valve

p:

Pump efficiency (not


considering check valve)
NPSH: Net positive suction head
required by the pump

Pump End G 3
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall
length (mm)

Dmax
(mm)

G 21/2

40

G 3

48

G 4

93

DN 50

77

165

DN 65

77

185

DN 80

77

200

see
page 45

Threaded end to DIN ISO 228, Part 1.


Flange end to DIN 2501, Part 1
G 3

Dmax

Lp

LA

43

60 Hz

UPA 150C

Technical Data
Pumps with submersible motors for ...

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Rated
current

Efficiency

Power
factor

Number x cross-section
of conductors (use under
water, 460 V and +30 _C)

tmax 1)
_C

IN
A

M
%

cos
----

d.o.l.
mm2

Y-
mm2

H0
m

PN
kW

1 + DN 100 - 1.5

15.6

1.8

30

4.1

74.0

0.80

4 x 1.5

--

2 + DN 100 - 3.0

31.0

3.4

30

7.4

79.0

0.76

4 x 1.5

--

3 + UMA 150D 5/21

49.0

5.0

43

11.4

75.0

0.77

4 x 2.5

3/4 x 2.5

4 + UMA 150D 5/21

64.0

6.5

39

13.6

75.5

0.83

4 x 2.5

3/4 x 2.5

5 + UMA 150D 7/21

80.0

8.0

38

16.4

77.0

0.82

4 x 2.5

3/4 x 2.5

6 + UMA 150D 7/21

95.0

9.0

33

18.0

76.5

0.84

4 x 2.5

3/4 x 2.5

UPA 150C -- 30 / ...

PN
hp

Max. temperature
of the fluid pumped
v 0.5 m/s

7 + UMA 150D 9/21

111.0

11.0

33

21.0

78.0

0.84

4 x 2.5

3/4 x 2.5

8 + UMA 150D 13/21

129.0

12.5

39

24.5

82.0

0.79

4 x 2.5

3/4 x 2.5

9 + UMA 150D 13/21

144.0

14.0

37

26.5

82.0

0.81

4 x 2.5

3/4 x 2.5

10 + UMA 150D 13/21

159.0

15.5

34

29.0

81.5

0.83

4 x 2.5

3/4 x 2.5

11 + UMA 150D 15/21

176.0

17.0

36

31.0

82.5

0.84

4 x 4.0

3/4 x 2.5

12 + UMA 150D 15/21

190.0

18.0

33

33.0

82.0

0.84

4 x 4.0

3/4 x 2.5

13 + UMA 150D 18/21

208.0

20.0

34

37.0

83.0

0.82

4 x 4.0

3/4 x 2.5

14 + UMA 150D 18/21

223.0

22.0

32

40.5

82.5

0.83

4 x 4.0

3/4 x 2.5

15 + UMA 150D 22/21

241.0

24.0

37

44.0

84.5

0.81

4 x 4.0

3/4 x 2.5

16 + UMA 150D 22/21

256.0

25.0

36

45.5

84.5

0.82

4 x 4.0

3/4 x 2.5

17 + UMA 150D 22/21

271.0

26.0

34

47.0

84.5

0.83

4 x 4.0

3/4 x 2.5

18 + UMA 150D 26/21

289.0

28.0

38

51.0

85.5

0.82

4 x 6.0

3/4 x 4.0

19 + UMA 150D 26/21

304.0

30.0

37

54.0

85.5

0.83

4 x 6.0

3/4 x 4.0

20 + UMA 150D 26/21

319.0

31.0

36

55.0

85.5

0.84

4 x 6.0

3/4 x 4.0

21 + UMA 150D 30/21

338.0

33.0

38

60.0

86.0

0.81

4 x 6.0

3/4 x 4.0

22 + UMA 150D 30/21

353.0

34.0

37

62.0

86.0

0.82

4 x 6.0

3/4 x 4.0

23 + UMA 150D 30/21

368.0

36.0

36

64.0

85.5

0.83

4 x 6.0

3/4 x 4.0

1) also see page 34

44

2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.

60 Hz

UPA 150C

Dimensions / Weights / Horizontal Installation 1)


UPA 150C -- 30 / ...

LP
mm

mA kg
g

LA mm

Dmax mm

Installation 2)

C1 (AISI 304)

C2 (AISI 316)

d.o.l.

Y-

389

715

715

20

139

--

v 3)

485

910

910

25

139

--

v 3)

613

1315

1310

60

146

148

v+h

709

1410

1410

61

146

148

v+h

805

1525

1525

65

146

148

v+h

901

1620

1620

67

146

148

v+h

997

1750

1745

71

146

148

v+h

1093

1925

1920

80

146

148

v+h

1189

2020

2020

81

146

148

v+h

10

1285

2115

2115

83

146

148

v+h

11

1381

2255

2255

88

147

148

v+h

12

1477

2355

2350

90

147

148

v+h

13

1573

2495

2490

96

147

148

v+h

14

1669

2590

2590

97

147

148

v+h

15

1765

2775

2775

107

147

148

v+h

16

1861

2870

2870

108

147

148

v+h

17

1957

2970

2965

110

147

148

v+h

18

2053

3170

3165

121

149

149

v 3)

19

2149

3265

3265

122

149

149

v 3)

20

2245

3360

3360

124

149

149

v 3)

21

2341

3555

3555

134

149

149

v 3)

22

2437

3655

3650

136

149

149

v 3)

23

2533

3750

3745

138

149

149

v 3)

1) Including check valve with threaded end and standard motor leads.

2) v = vertical / h = horizontal.

3) horizontale installation on request

45

60 Hz

UPA 150C -- 48 / ...; number of stages 1 -- 14


The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv :

Head losses in the check


valve

p:

Pump efficiency (not


considering check valve)
NPSH: Net positive suction head
required by the pump

Pump End G 3
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall
length (mm)

Dmax
(mm)

G 21/2

40

G 3

48

G 4

93

DN 50

77

165

DN 65

77

185

DN 80

77

200

see
page 47

Threaded end to DIN ISO 228, Part 1.


Flange end to DIN 2501, Part 1
G 3

Dmax

Lp

LA

46

UPA 150C

60 Hz

UPA 150C

Technical Data
Pumps with submersible motors for ...

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature
of the fluid pumped
v 0.5 m/s

Rated
current

Efficiency

Power
factor

tmax 1)
_C

IN
A

M
%

cos
----

d.o.l.
mm2

H0
m

PN
kW

1 + DN 100 - 3.0

19.2

3.4

30

7.4

79.0

0.76

4 x 1.5

--

2 + UMA 150D 5/21

40.0

6.0

41

12.9

75.5

0.81

4 x 2.5

3/4 x 2.5

3 + UMA 150D 7/21

59.0

8.5

36

17.2

77.0

0.83

4 x 2.5

3/4 x 2.5

4 + UMA 150D 9/21

79.0

11.0

33

21.0

78.0

0.84

4 x 2.5

3/4 x 2.5

5 + UMA 150D 13/21

100.0

14.0

37

26.5

82.0

0.81

4 x 2.5

3/4 x 2.5

6 + UMA 150D 15/21

119.0

16.5

36

30.5

82.5

0.83

4 x 4.0

3/4 x 2.5

7 + UMA 150D 18/21

140.0

20.0

35

37.0

83.0

0.82

4 x 4.0

3/4 x 2.5

8 + UMA 150D 18/21

158.0

22.0

31

40.5

82.5

0.83

4 x 4.0

3/4 x 2.5

9 + UMA 150D 22/21

179.0

25.0

36

45.5

84.5

0.82

4 x 4.0

3/4 x 2.5

10 + UMA 150D 26/21

200.0

28.0

38

51.0

85.5

0.82

4 x 6.0

3/4 x 4.0

11 + UMA 150D 26/21

218.0

31.0

36

55.0

85.5

0.84

4 x 6.0

3/4 x 4.0

12 + UMA 150D 30/21

240.0

34.0

37

62.0

86.0

0.82

4 x 6.0

3/4 x 4.0

13 + UMA 150D 30/21

258.0

36.0

35

64.0

85.5

0.83

4 x 6.0

3/4 x 4.0

14 + UMA 150D 37/22

279.0

40.0

48

72.0

85.0

0.82

3/4 x 4.0 3)

3/4 x 4.0

UPA 150C -- 48 / ...

1) also see page 34

PN
hp

Number x cross-section
of conductors (use under
water, 460 V and +30 _C)

2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.

Y-
mm2

3) Parallel cable

Dimensions / Weights / Horizontal Installation 1)


UPA 150C -- 48 / ...

LP
mm

LA mm
C1 (AISI 304)

mA kg

C2 (AISI 316)

Dmax mm
d.o.l.

Installation 2)

Y-

406

830

830

26

139

--

v+h

551

1250

1250

61

143

146

v+h

664

1385

1385

65

143

146

v+h

777

1530

1525

71

143

146

v+h

890

1720

1720

80

143

146

v+h

1003

1880

1875

86

145

146

v+h

1116

2035

2035

92

145

146

v+h

1229

2150

2150

95

145

146

v+h

1342

2355

2350

105

145

146

v+h

10

1455

2570

2570

116

146

147

v+h

11

1568

2685

2680

119

146

147

v+h

12

1681

2895

2895

130

146

147

v+h

13

1794

3010

3010

132

146

147

v 3)

14

1907

3205

3200

141

146

147

v 3)

1) Including check valve with threaded end and standard motor leads.

2) v = vertical / h = horizontal.

3) horizontale installation on request

47

60 Hz

UPA 150C -- 60 / ...; number of stages 1 -- 11


The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv :

Head losses in the check


valve

p:

Pump efficiency (not


considering check valve)
NPSH: Net positive suction head
required by the pump

Pump End G 3
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall
length (mm)

Dmax
(mm)

G 21/2

40

G 3

48

G 4

93

DN 50

77

165

DN 65

77

185

DN 80

77

200

see
page 49

Threaded end to DIN ISO 228, Part 1.


Flange end to DIN 2501, Part 1
G 3

Dmax

Lp

LA

48

UPA 150C

60 Hz

UPA 150C

Technical Data
Pumps with submersible motors for ...

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature
of the fluid pumped
v 0.5 m/s

Rated
current

Efficiency

Power
factor

tmax 1)
_C

IN
A

M
%

cos
----

d.o.l.
mm2

H0
m

PN
kW

1 + DN 100 - 3.0

19.4

3.4

30

7.4

79.0

0.76

4 x 1.5

--

2 + UMA 150D 5/21

40.0

6.6

37

13.8

75.5

0.83

4 x 2.5

3/4 x 2.5

3 + UMA 150D 9/21

60.0

10.0

36

19.8

78.5

0.83

4 x 2.5

3/4 x 2.5

4 + UMA 150D 13/21

81.0

13.5

38

26.0

82.0

0.81

4 x 2.5

3/4 x 2.5

5 + UMA 150D 15/21

101.0

16.5

36

30.5

82.5

0.83

4 x 4.0

3/4 x 2.5

6 + UMA 150D 18/21

121.0

20.0

34

37.0

83.0

0.82

4 x 4.0

3/4 x 2.5

7 + UMA 150D 22/21

142.0

24.0

37

44.0

84.5

0.81

4 x 4.0

3/4 x 2.5

8 + UMA 150D 22/21

161.0

26.4

34

47.5

84.5

0.83

4 x 4.0

3/4 x 2.5

9 + UMA 150D 26/21

182.0

30.0

37

54.0

85.5

0.83

4 x 6.0

3/4 x 4.0

10 + UMA 150D 30/21

203.0

34.0

37

62.0

86.0

0.82

4 x 6.0

3/4 x 4.0

11 + UMA 150D 37/22

223.0

38.0

50

69.0

85.5

0.81

3/4 x 4.0 3)

3/4 x 4.0

UPA 150C -- 60 / ...

1) also see page 34

PN
hp

Number x cross-section
of conductors (use under
water, 460 V and +30 _C)

2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.

Y-
mm2

3) Parallel cable

Dimensions / Weights / Horizontal Installation 1)


UPA 150C -- 60 / ...

LP
mm

mA kg
g

LA mm
C1 (AISI 304)

C2 (AISI 316)

Dmax mm
d.o.l.

Y-

Installation 2)

406

830

830

25

139

--

v+h

551

1250

1250

61

143

146

v+h

664

1415

1415

68

143

146

v+h

777

1610

1605

78

143

146

v+h

890

1765

1765

84

145

146

v+h

1003

1925

1920

90

145

146

v+h

1116

2125

2125

100

145

146

v+h

1229

2240

2240

103

145

146

v+h

1342

2460

2455

114

146

147

v+h

10

1455

2670

2670

125

146

147

v+h

11

1568

2865

2860

134

145

147

v 3)

1) Including check valve with threaded end and standard motor leads.

2) v = vertical / h = horizontal.

3) horizontale installation on request

49

60 Hz

50

UPA 150C

UPA 200, 200B, 250C

60 Hz
Applications

Submersible Borehole Pumps

Handling clean or slightly contaminated water ...


-- in general water supply systems,
-- in irrigation and spray irrigation systems,
-- in pressure boosting systems,
-- in emergency water supply systems,
-- in installations for lowering and maintaining ground water
levels.

for Well Diameters


of 200 mm (8 inches) and Above
and of 250 mm (10 inches) and Above

Also used in ...


-- mining,
-- sprinkler installations,
-- fountains etc
Permissible sand content in the fluid handled: 50 g/m3.
Also suitable for aggressive seawater if supplied in material
variant C3 (duplex).

Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 400 m3/h (111 l/s
or up to 1600 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 434 m
Temperature of fluid handled . . t

up to +50 C

Speed . . . . . . . . . . . . . . . . . . . . . n

3500 rpm

Design
Single or multistage, single-entry centrifugal pumps in
ring-section design. Mixed flow hydraulic systems with
impellers that can be turned down. Stage casings connected by
means of studs. Suction casing fitted between pump and motor.
Suction casing equipped with strainer to protect the pump from
coarse particles in the fluid.
Pumps with non-return valve or connection branch on option.
Both models available with either threaded or flanged end.
Particularly suitable for vertical installation in narrow deep
wells.

Designation (Example)
UPA 200 B -- 80 B / 5 d
Type series
Minimum well diameter (mm)
(for ex.: 200 mm = 8 inches)

Design status
Capacity Qopt for 50 Hz (m3/h)
Impeller material1)
without code letter:
with code B:

execution G
execution B

Number of stages
Reduced impeller diameters
1) Applies

to UPA 200B only.

Certification

Product Features
---------

Very sturdy design


Suitable for installation in narrow deep wells
High efficiency
Motor designed for maximum pump output
Low noise level
For vertical or horizontal installation
Non-return valve protected against blocking
Pre-filled motor; no risk of contamination of the handled
water

Quality management certified to ISO 9001

51

60 Hz

UPA 200, 200B, 250C

Selection Chart (Ranges on Offer)

n 3500 rpm

UPA 250C -- 120

UPA 250C -- 250

UPA 200B -- 80
UPA 200 -- 11
UPA 250C -- 150
UPA 200 -- 14

UPA 200B -- 130

UPA 200-14

UPA 250C-120

UPA 200B-80

UPA 200-11
UPA 250C-250
UPA 200B-130

UPA 250C-150

Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this range. The operating
ranges QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages.
Selection charts or performance curves for UPA in material variant C3 (duplex) on request only.
52

UPA 200, 200B, 250C

60 Hz
UPA 200

Threaded End

Flanged End

Material Variants
Component

Execution G

Casing

Cast iron
Bronze
(JL1030) 1)
(CC480K--GS) 2)
Glass fibre reinforced NORYL
(PPO)
Glass fibre reinforced NORYL
(PPO)
Cr steel
CrNiMo steel
(1.4021)
(1.4462)
CrNiMo steel (1.4401)
CrNiMo steel
(A4-70)

Impeller
Diffuser
Shaft
Wear ring
Screws, bolts
and nuts
1)

DIN mat. code: GG-20

2)

Execution B

DIN mat. code: CuSn10

Bearings / Lubrication
Plain bearing in the end stage, lubricated by the fluid handled.
Axial thrust is balanced by a thrust bearing in the motor.

Direction of Rotation of the Pump


Clockwise rotation (when looking at the drive shaft end).

Pump End (Discharge Nozzle)


UPA 200 - 11 + 14: internal thread G 3 (DN 80). Flanged end
with adapter also available (see Accessories).

Variants Available on Request


---

Pumps with flanged end


Pumps with connection branch with either threaded
or flanged end
3410:8/3

Example: UPA 200 - 14/3 with UMA 150D .. / 2.

Part No

Description

106/108
143
171
211
232
503
529/545
751
849
917

Suction casing / Stage casing


Suction strainer
Diffuser
Pump shaft
Clockwise impeller
Impeller wear ring
Bearing sleeve / Bearing bush
Valve body
Sleeve coupling
Tie bolt

53

60 Hz
UPA 200B, 250C

Pump End (Discharge Nozzle)


At choice with female thread G 5 and G 6 or flange DN 125
and DN 150 dependent on pump size.

Material Variants
G

UPA pump

(Standard)

(Special)

(Duplex)

Casing

Cast iron
(JL1040) 1)

Bronze
(CC480K-GS) 2)

CrNiMo steel
(1.4517)

Impeller

200B

250C

Shaft
Wear ring

C3

Glass fibre
Bronze
reinforced
(CC480K-GS) 5)
CrNiMo steel
NORYL
(1.4517)
(PPO)
2)
Bronze (CC480K-GS)
Cr steel
CrNiMo steel
(1.4021)
(1.4462)
high-performance plastics

CrNiMo steel
(1.4538)

CrNiMo steel
(A4--70)

CrNiMo steel
(1.4462)

Screws, bolts
and nuts 4)

C2

C3

UMA motor

(Standard)

(Special)

(Duplex)

Shaft

CrNi steel
(1.4305)

CrNiMo steel
(1.4462)

CrNiMo steel
(1.4462)

CrNiMo steel
(1.4462)

150D
200D
250D
300D

Housing
g

Stator
case

Screws
bolts
and
d
nuts 4)

1)
2)

UPA 200, 200B, 250C

150D

Cast iron
(JL1030) 3)

CrNiMo steel
(1.4409)

CrNiMo steel
(1.4539)

200D
250D

Cast iron
(JL1030) 3)

CrNiMo steel
(1.4408)

CrNiMo steel
(1.4539)

300D

Cast iron
(JL1040) 1)

150D

CrNi steel
(1.4301)

CrNiMo steel
(1.4571)

CrNiMo steel
(1.4539)

200D
250D

CrNiMo steel
(1.4301)

CrNiMo steel
(1.4571)

CrNiMo steel
(1.4539)

300D

CrNiMo steel
(1.4301)

150D

CrNi steel
(1.4301)

CrNiMo steel
(1.4517)

CrNiMo steel
(1.4462)
CrNiMo steel
(A4--70)

CrNiMo steel
(1.4539)

200D
250D

CrNiMo steel
(A4--70)

CrNiMo steel
(1.4539)

300D

CrNiMo steel
(A4--70)

CrNiMo steel
(1.4462)

3)
4)
5)

DIN mat. code GG-20


Wetted by fluid handled
for size 80B and 130B

DIN mat. code: GG-25


DIN mat. code: CuSn10

Bearings / Lubrication
Radial plain bearings; lubricated by the liquid handled or by the
motor filling water. Depending on the number of stages 1
intermediate bearings is fitted on the pump unit.
The axial thrust is balanced by a thrust bearing with
self-adjusting tilting pads in the lower part of the motor.

Direction of Rotation of the Pump


Clockwise rotation (when looking at the drive shaft end).
54

Coating (Standard)
Quality . . . . . . . . . . . 2-component high-build coating
(epoxy resin base), approved for drinking
water contact
Coating structure . . Primer and top coat
Film thickness . . . . 100 to 150 m
Colour . . . . . . . . . . . ultramarine blue (RAL 5002)

Type of Installation
In general, the pumps are installed vertically. Some models
may also be installed horizontally depending on the number of
stages and motor size.

Drive
Motor type . . . . . . . . water-filled submersible
squirrel-cage motor, 2 poles
Type of enclosure . IP 68
Frequency . . . . . . . . 60 Hz
Type of current . . . . three-phase (3~)
Rated voltage U . . . 440 V ... 460 V
Rated power PN . . . up to 225 kW ( 301.7 hp)
Frequency of starts 15/h 1) and 10/h 2)
Minimum delay
before restarting . . 1 min 1) and 3 min 2)
Motor design is in compliance with VDE regulations.
1)
2)

Motor UMA 150D


Motors UMA 200D and 250D

Connection to Power Supply


The motors are normally equipped ex works as follows with
short flat cables ...
-- UMA 150D:
1 x 4 m with 4 conductors (3 phases + 1 earth conductor)
for direct starting or
1 x 4 m with 3 conductors and 1 x 4 m with 4 conductors (3
phases + 1 earth conductor) for direct and star-delta
starting,
-- UMA 200D + UMA 250D:
1 x 6 m with 3 conductors and 1 x 6 m with 4 conductors (3
phases + 1 earth conductor) for direct and star-delta
starting.
All motor sizes are equipped with internal earthing.
Connection of extension cable on short cable by means of a
waterproof cable connector (see accessories )
Short cable and extension cable in food quality.
Note: The cross-section of short cable is only designed for
underwater use. For laying partially or completely in air it is
necessary to check the cross-section of this cable.

60 Hz

UPA 200, 200B, 250C

Starting
Direct on line (without or with starting transformer as well as
with smooth running device) or star-delta starting.

Variable Speed
The submersible motor pumps can also be adjusted with a
speed adjustment to different duty points.

Application Temperatures
The submersible borehole pumps are, as a standard, suitable for
use in water with temperatures of up to t = +30 C. An
indispensable requirement for this is a flow velocity of v = 0.5 m/s
past the motor. This requirement is met, for example, when the
pump is installed in a deep well above the well screen / filter, etc.
With certain restrictions, some motor sizes may also be used
in water with temperatures of up to t = +50 C or for operation
without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).

Variants Available on Request


--------

UPA 200B pumps with impellers out of Bronze


other materials
other or higher voltages until 6600 V
other frequencies
more wear resistant design
pump with connection nozzle (instead of non-return valve)
with cooling, suction or pressure shroud

55

60 Hz

UPA 200, 200B, 250C

Design Features

All wetted plastic components are


approved for contact drinking
water (BAM 1))
-- Coating, electric cables, seal
elements, gaskets, etc. are
absolutely fit for use in drinking
water applications.

Check valve with anti-blockage


valve disc
-- No jamming or tilting.
-- Spring-loaded design makes for minimum valve closing times and prevents
waterhammer.
-- High operating reliability.

1) German Federal Institute for Materials


Research

Robust wear rings


-- Replaceable wear rings made of
corrosion- and wear-resistant metal.
-- Protection against wear in the
clearance; easy servicing.

Enclosed pump bearing


-- No-maintenance design, high wear
resistance.
-- For trouble-free long-term
operation.

Energy-efficient hydraulic systems


-- High efficiency and low energy
costs.

Integrated sand separator


-- Tried and tested KSB patent.
-- Added protection from abrasive wear
for shafts and bearing areas.
-- Long service life and high operating
reliability.

The KSB motor


-- VDE-compliant, i.e., high level of
electrical safety.
-- Designed for max. pump power
to protect unit from overloads.

Wear-resistant mechanical seal


-- Long service life and high
operating reliability.

Counter thrust bearing


-- Reliable balancing of negative axial
thrust.
-- Impellers do not rub on the stage
casings.

56

H04004669

Tried and tested thrust bearing


-- Water-lubricated self-aligning
tilting-pad journal bearing.
-- No-maintenance design suitable for
maximum load-carrying capacity
under continuous operation
conditions.
-- New materials combination (stainless
steel / carbon) for high safety factor.

Dynamically balanced rotor


-- Ensures smooth running.

Reliable pressure balancing


system
-- Optimum rubber expansion
diaphragm design.
-- Enables installation at very low
depths.

60 Hz

UPA 200, 200B, 250C

57

60 Hz

UPA 200

UPA 200 11 for Well Diameters of 200 mm (8 inches) and Above


Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature of
the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and +30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1e + UMA 150D 5/21


1d + UMA 150D 5/21
1 + UMA 150D 5/21

26.5
29.2
32.5

4.0
4.5
5.5

5.4
6.0
7.4

45
44
42

10.1
10.7
12.1

73.5
74.6
75.5

0.71
0.74
0.79

4 x 2.5
4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)

2e + UMA 150D 7/21


2c + UMA 150D 7/21
2 + UMA 150D 9/21

51.9
58.6
63.9

7.5
9.0
10.5

10.1
12.1
14.1

40
35
35

15.6
18.0
20.5

77.3
76.7
78.4

0.81
0.84
0.84

4 x 2.5
4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)

3d + UMA 150D 13/21


3 + UMA 150D 13/21

86.6
96.0

12.0
15.0

16.1
20.1

40
35

23.5
28.5

82.0
81.6

0.78
0.82

4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)

4c + UMA 150D 15/21


4 + UMA 150D 18/21

117.7
128.3

17.0
21.0

22.8
28.2

36
34

31.0
39.0

82.5
82.9

0.84
0.82

4 x 4.0
4 x 4.0

3/4 x 2.5 4)
3/4 x 2.5 4)

5b + UMA 150D 18/21


5 + UMA 150D 22/21

149.1
160.4

22.0
26.0

29.5
34.9

32
35

40.5
47.0

82.7
84.5

0.83
0.83

4 x 4.0
4 x 4.0

3/4 x 2.5 4)
3/4 x 2.5 4)

6b + UMA 150D 22/21


6 + UMA 150D 26/21

179.3
192.4

26.0
31.0

34.9
41.6

34
36

47.0
55.0

84.5
85.4

0.83
0.84

4 x 4.0
4 x 6.0

3/4 x 2.5 4)
3/4 x 4.0 4)

224.9

36.0

48.3

36

64.0

85.6

0.83

4 x 6.0

UPA 200 -- 11/ ... + ..

+ UMA 150D 30/21

+ UMA 150D 37/22

256.9

42.0

56.3

47

76.0

85.1

0.83

3/4 x 4.0 4)

3/4 x 4.0 II

3)

3/4 x 4.0 4)

3)

3/4 x 4.0 4)

+ UMA 150D 37/22

287.0

44.0

59.0

43

78.0

84.9

0.84

3/4 x 4.0 II

10 + UMA 200D 45/21

322.4

52.0

69.7

31

89.0

85.7

0.87

4 x 10.0

1)
2)
3)
4)

3/4 x 6.0 4)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.

Dimensions / Weights / Horizontal Installation 1)


LP
UPA 200 - 11/ ..

1)
2)
3)

mm

LA mm

mA in kg

Standard

Special

Standard

Special

D.o.l.

Y-

Installation 2)

A
mm

1e
1d
1

515
515
515

1214
1214
1214

1214
1214
1214

67
67
68

70
70
71

192
192
192

195
195
195

v+h
v+h
v+h

645
645
645

2e
2c
2

580
580
580

1299
1299
1329

1299
1299
1329

73
73
76

77
77
80

192
192
192

195
195
195

v+h
v+h
v+h

720
720
735

3d
3

645
645

1474
1474

1474
1474

86
86

90
90

192
192

195
195

v+h
v+h

840
840

4c
4

710
710

1584
1629

1584
1629

93
97

98
102

193
193

195
195

v+h
v+h

927
950

5b
5

775
775

1694
1784

1694
1784

101
109

106
114

193
193

195
195

v+h
v+h

1015
1060

6b
6

840
840

1849
1954

1849
1954

112
122

118
128

193
194

195
196

v+h
v+h

1125
1177

905

2119

2119

134

140

194

196

v+h

1292

970

2264

2264

146

153

196

196

v 3)

----

3)

1035

2329

2329

148

155

196

196

10

1110

2341

2341

207

215

196

199

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.

58

Dmax in mm

v+h

---1506

60 Hz

UPA 200

UPA 200 - 11 / ..
The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

UPA 200 -- 11 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are
not considered in the pump characteristic
curves.
For more details and a selection example
refer to page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 3 / DN 80
The information is based on the model with
check valve / connection branch and
threaded end.
The changes in the main dimensions of the
flanged end model are specified in the table
below.
Check valve / connection branch with:
Threaded
end G 3

Flanged end
DN 80

Length
mm

Length
mm

Outside dia.
mm

200

200 (PN 10/16)


200 (PN 25/40)

200
200

Operating range:
Qmin = 10 m3/h
Qmax = End of characteristic curve

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.

Optimum impeller dia. d

Maximum impeller dia.

59

60 Hz

UPA 200

UPA 200 --14 for Well Diameters of 200 mm (8 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature of
the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and +30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

5/21
5/21
7/21

25.1
30.2
35.5

5.0
6.0
7.5

6.7
8.0
10.1

43
41
40

11.4
12.9
15.6

75.2
75.5
77.3

0.77
0.81
0.81

4 x 2.5
4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)

2e + UMA 150D 9/21


2d + UMA 150D 9/21
2 + UMA 150D 13/21

50.4
60.4
72.1

10.0
11.2
14.5

13.4
15.0
19.4

36
31
36

19.8
21.5
27.5

78.5
78.1
81.7

0.83
0.85
0.82

4 x 2.5
4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)

3d + UMA 150D 15/21


3 + UMA 150D 18/21

92.1
108.7

17.5
22.0

23.5
29.5

34
32

32.0
40.5

82.4
82.7

0.84
0.83

4 x 4.0
4 x 4.0

3/4 x 2.5 4)
3/4 x 2.5 4)

4c + UMA 150D 22/21


4 + UMA 150D 26/21

131.2
145.9

25.0
29.0

33.5
38.9

35
37

45.5
52.0

84.6
85.6

0.82
0.83

4 x 4.0
4 x 6.0

3/4 x 2.5 4)
3/4 x 4.0 4)

5c + UMA 150D 26/21


5 + UMA 150D 30/21

163.6
182.1

31.2
36.0

41.8
48.3

35
35

55.0
64.0

85.4
85.6

0.84
0.83

4 x 6.0
4 x 6.0

3/4 x 4.0 4)
3/4 x 4.0 4)

6c + UMA 150D 37/22


6 + UMA 150D 37/22

197.7
217.7

38.0
44.0

51.0
59.0

49
45

69.0
78.0

85.4
84.9

0.81
0.84

3/4 x 4.0 II 3)
3/4 x 4.0 II 3)

3/4 x 4.0 4)
3/4 x 4.0 4)

7c + UMA 150D 37/22


7 + UMA 200D 45/21

228.7
256.0

44.0
52.0

59.0
69.7

44
30

78.0
89.0

84.9
85.7

0.84
0.87

3/4 x 4.0 II 3)
4 x 10

3/4 x 4.0 4)
3/4 x 6.0 4)

+ UMA 200D 55/21

294.1

60.0

80.5

32

101.0

86.8

0.86

4 x 16.0

3/4 x 6.0 4)

+ UMA 200D 65/21

332.2

68.0

91.2

34

115.0

87.6

0.85

3/4 x 10 II 3)

3/4 x 10.0 4)

UPA 200 -- 14/ ... + ...


1e + UMA 150D
1d + UMA 150D
1 + UMA 150D

1)
2)
3)
4)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.

Dimensions / Weights / Horizontal Installation 1)


LP

mA in kg

Installation 2)

Standard

Special

Standard

Special

D.o.l.

Y-

1e
1d
1

530
530
530

1229
1229
1249

1229
1229
1249

68
68
70

71
71
73

192
192
192

195
195
195

v+h
v+h
v+h

660
660
670

2e
2d
2

610
610
610

1359
1359
1439

1359
1359
1439

77
77
84

81
81
88

192
192
192

195
195
195

v+h
v+h
v+h

765
765
805

3d
3

690
690

1564
1609

1564
1609

92
96

96
100

193
193

195
195

v+h
v+h

907
930

4c
4

770
770

1779
1884

1779
1884

108
117

113
123

193
194

195
196

v+h
v+h

1055
1107

5c
5

850
850

1964
2064

1964
2064

125
134

130
139

194
194

196
196

v+h
v+h

1187
1237

6c
6

930
930

2224
2224

2224
2224

144
144

150
150

196
196

196
196

v 3)
v 3)

-------

7c
7

1020
1020

2314
2251

2314
2251

148
204

154
210

196
196

196
199

v 3)
v+h

---1416

1100

2441

2441

228

235

199

199

v+h

1551

1180

2651

2651

252

259

199

199

v+h

1696

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.

60

Dmax in mm

mm

UPA 200 -- 14/ ..

1)
2)
3)

LA mm

mm

60 Hz

UPA 200

UPA 200 - 14 / ..
The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.

UPA 200 -- 14 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are
not considered in the pump characteristic
curves.
For more details and a selection example
refer to page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 3 / DN 80
The information is based on the model with
check valve / connection branch and
threaded end.
The changes in the main dimensions of the
flanged end model are specified in the table
below.
Check valve / connection branch with
Threaded
end G 3

Flanged end
DN 80

Length
mm

Length
mm

Outside dia.
mm

200

200 (PN 10/16)


200 (PN 25/40)

200
200

Operating range:
Qmin = 12 m3/h
Qmax = End of characteristic curve

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.

Maximum impeller dia.

Optimum impeller dia. d

61

60 Hz

UPA 200B, 250C

UPA 200B -- 80 for Well Diameters of 200 mm (8 inches) and Above


Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump
Discharge
head
Q = 0 m3/h

UPA 200B -- 80/.. + ...

Motor lead 2), flat

Motor
Rated
power

Max. temperature
of the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and 30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1g
1f
1d
1

+ UMA 150D 7/21


+ UMA 150D 9/21
+ UMA 150D 13/21
+ UMA 150D 13/21

29.1
34.1
36.8
39.1

9.0
10.5
12.5
14.0

12.1
14.1
16.8
18.8

33
34
39
37

18.0
20.5
24.5
26.5

76.7
78.4
82.0
81.8

0.84
0.84
0.79
0.81

4 x 2.5
4 x 2.5
4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)

2g
2f
2d
2

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

15/21
18/21
22/21
26/21

55.7
64.0
69.2
76.2

17.0
21.0
25.0
28.0

22.8
28.2
33.5
37.5

35
34
36
38

31.0
39.0
45.5
51.0

82.5
82.9
84.6
85.7

0.84
0.82
0.82
0.82

4 x 4.0
4 x 4.0
4 x 4.0
4 x 6.0

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 4.0 4)

3f
3e
3c
3

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

26/21
26/21
30/21
37/22

97.3
101.6
107.0
113.4

28.0
31.0
36.0
40.0

37.5
41.6
48.3
53.6

38
36
35
48

51.0
55.0
64.0
72.0

85.7
85.4
85.6
85.2

0.82
0.84
0.83
0.82

4 x 6.0
4 x 6.0
4 x 6.0
3/4 x 4.0 II 3)

3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)

4e + UMA 150D 37/22


4c + UMA 200D 45/21
4 + UMA 200D 55/21

135.8
143.6
152.9

42.0
50.0
54.0

56.3
67.1
72.4

46
32
35

76.0
86.0
93.0

85.1
85.7
86.7

0.83
0.86
0.85

3/4 x 4.0 II 3)
4 x 10.0
4 x 16.0

3/4 x 4.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)

5d + UMA 200D 55/21


5 + UMA 200D 65/21

177.1
191.0

58.0
68.0

77.8
91.2

33
34

99.0
115.0

86.8
87.6

0.86
0.85

4 x 16.0
3/4 x 10.0 II 3)

3/4 x 6.0 4)
3/4 x 10.0 4)

6c + UMA 200D 65/21


6 + UMA 200D 75/21

215.9
228.5

74.0
80.0

99.2
107.3

31
31

124.0
136.0

87.6
87.5

0.86
0.85

3/4 x 10.0 II 3)
3/4 x 10.0 II 3)

3/4 x 10.0 4)
3/4 x 10.0 4)

7c + UMA 200D 90/21


7 + UMA 200D 90/21

253.8
267.4

90.0
95.0

120.7
127.4

34
32

156.0
162.0

88.2
88.2

0.83
0.84

3/4 x 16.0 II 3)
3/4 x 16.0 II 3)

3/4 x 16.0 4)
3/4 x 16.0 4)

8c + UMA 200D 90/21


8 + UMA 250D 110/21

288.4
309.4

100.0
110.0

134.1
147.5

30
33

169.0
188.0

88.2
88.7

0.85
0.83

3/4 x 16.0 II 3)
3/4 x 16.0 II 3)

3/4 x 16.0 4)
3/4 x 25.0 4)

1)
2)
3)
4)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax in mm

Installation 2)

UPA 200B -- 80/..

mm

Standard

Special

Standard

Special

D.o.l.

Y-

1g
1f
1d
1

582
582
582
582

1301
1331
1411
1411

1301
1331
1411
1411

89
92
99
99

95
98
105
105

193
193
193
193

196
196
196
196

v+h
v+h
v+h
v+h

632
647
687
687

2g
2f
2d
2

714
714
714
714

1588
1633
1723
1828

1588
1633
1723
1828

113
117
125
134

122
126
134
143

194
194
194
195

196
196
196
198

v+h
v+h
v+h
v+h

841
864
909
961

3f
3e
3c
3

846
846
846
846

1960
1960
2060
2140

1960
1960
2060
2140

145
146
155
162

155
156
165
172

195
195
195
198

198
198
198
198

v+h
v+h
v+h
v 3)

1093
1093
1143
--

4e
4c
4

978
978
978

2272
2209
2319

2272
2209
2319

172
225
245

184
237
257

198
201
205

198
201
201

v 3)
v+h
v+h

-1284
1339

5d
5

1110
1110

2451
2581

2451
2581

256
279

269
292

205
201

201
205

v+h
v+h

1471
1536

6c
6

1242
1242

2713
2803

2713
2803

289
305

304
320

201
205

205
205

v+h
v+h

1668
1713

7c
7

1374
1374

3115
3115

3115
3115

348
348

364
364

211
211

211
211

v 3) 4)
v 3) 4)

---

8c
8

1506
1506

3247
3035

3247
3035

358
428

446
446

211
232

211
235

v 3) 4)
v 4)

---

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

62

mm

60 Hz

UPA 200B, 250C

UPA 200B -- 80 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 200B -- 80 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The characteristic curves shown apply to the
standard impeller material, i.e. Noryl.
The performance data for the full impeller diameter
and impeller diameter b for the given number of
stages will only be achieved when the impellers are
made of Noryl (PPO).
For the special impeller material (bronze), please
select the next higher number of stages.
In this case, please refer to the characteristic curves
individually prepared for the quotation.
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Head losses in the check valve
Hv :
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 5 / DN 125


The information is based on the model with check
valve / connection branch and threaded end.

Operating range:
Qmin = 18 m3/h
Qmax = End of characteristic curve

The changes in the main dimensions of the flanged


end model are specified in the table below.
Check valve / connection branch with
Threaded
end G 5

Flanged end
DN 125

Length
mm

Length
mm

Outside dia.
mm

200

150 (PN 10/16)


150 (PN 25/40)

250
270

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.

Optimum
dia.fd
optimaler impeller
Laufrad-

Maximum Laufrad-
impeller dia.
maximaler

63

60 Hz

UPA 200B, 250C

UPA 200B -- 130 for Well Diameters of 200 mm (8 inches) and Above
Pumps with submersible motors for ...
Pump unit

Pump
Discharge
head
Q = 0 m3/h

UPA 200B -- 130/.. + ...

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Rated
power

Motor
Max. temperature of the
fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Motor lead 2), flat


Number x cross-section of
conductors (use under water,
460 V and +30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1g
1e
1c
1

+ UMA 150D 7/21


+ UMA 150D 9/21
+ UMA 150D 13/21
+ UMA 150D 13/21

24.6
28.8
33.2
35.6

9.0
11.2
13.5
15.5

12.1
15.0
18.1
20.8

33
32
38
34

18.0
21.5
26.0
29.0

76.7
78.1
81.9
81.4

0.84
0.85
0.81
0.83

4 x 2.5
4 x 2.5
4 x 2.5
4 x 2.5

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)

2g
2e
2d
2c
2

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

15/21
18/21
22/21
22/21
26/21

48.4
56.8
61.4
64.6
70.1

18.0
22.0
25.0
26.0
30.0

24.1
29.5
33.5
34.9
40.2

34
31
36
34
37

33.0
40.5
45.5
47.0
54.0

82.2
82.7
84.6
84.5
85.5

0.84
0.83
0.82
0.83
0.83

4 x 4.0
4 x 4.0
4 x 4.0
4 x 4.0
4 x 6.0

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 4.0 4)

3e
3d
3c
3

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

30/21
30/21
37/22
37/22

85.3
91.1
96.6
103.8

33.0
36.0
40.0
44.0

44.3
48.3
53.6
59.0

38
36
49
45

60.0
64.0
72.0
78.0

85.8
85.6
85.2
84.9

0.81
0.83
0.82
0.84

4 x 6.0
4 x 6.0
3/4 x 4.0 II 3)
3/4 x 4.0 II 3)

3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)

4d
4c
4b
4

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D

45/21
45/21
55/21
55/21

122.2
128.8
135.3
140.1

48.0
52.0
56.0
60.0

64.4
69.7
75.1
80.5

33
30
34
33

83.0
89.0
96.0
101.0

85.7
85.7
86.8
86.8

0.86
0.87
0.85
0.86

4 x 10
4 x 10
4 x 16
4 x 16

3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)

5c + UMA 200D 65/21


5b + UMA 200D 65/21
5 + UMA 200D 65/21

162.7
169.1
175.1

66.0
68.0
74.0

88.5
91.2
99.2

35
33
31

112.0
115.0
124.0

87.5
87.6
87.6

0.85
0.85
0.86

3/4 x 10 II 3)
3/4 x 10 II 3)
3/4 x 10 II 3)

3/4 x 10 4)
3/4 x 10 4)
3/4 x 10 4)

6c + UMA 200D 75/21


6b + UMA 200D 90/21
6 + UMA 200D 90/21

194.7
204.0
211.5

78.0
85.0
90.0

104.6
114.0
120.7

31
35
33

134.0
149.0
156.0

87.5
88.1
88.2

0.84
0.82
0.83

3/4 x 10 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)

3/4 x 10 4)
3/4 x 16 4)
3/4 x 16 4)

7c + UMA 200D 90/21


7b + UMA 200D 90/21
7 + UMA 250D 110/21

227.8
236.6
249.5

95.0
95.0
105.0

127.4
127.4
140.8

32
31
33

162.0
162.0
181.0

88.2
88.2
88.6

0.84
0.84
0.83

3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)

3/4 x 16 4)
3/4 x 16 4)
3/4 x 25 4)

8b + UMA 250D 110/21

273.8

115.0

154.2

32

195.0

88.7

0.84

3/4 x 16 II 3)

3/4 x 25 4)

1)
2)
3)
4)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax in mm

Installation 2)

UPA 200B -- 130/..

mm

Standard

Special

Standard

Special

D.o.l.

Y-

1g
1e
1c
1

545
595
595
595

1264
1344
1424
1424

1264
1344
1424
1424

89
92
99
99

99
99
106
106

193
193
193
193

196
196
196
196

v+h
v+h
v+h
v+h

585
650
690
690

2g
2e
2d
2c
2

740
740
740
740
740

1614
1659
1749
1749
1854

1614
1659
1749
1749
1854

113
117
125
125
135

122
126
134
135
144

194
194
194
194
195

196
196
196
196
198

v+h
v+h
v+h
v+h
v+h

857
880
925
925
977

3e
3d
3c
3

885
885
885
885

2099
2099
2179
2179

2099
2099
2179
2179

155
155
162
162

165
165
172
172

195
195
198
198

198
198
198
198

v+h
v+h
v 3)
v 3)

1172
1172
---

4d
4c
4b
4

1030
1030
1030
1030

2261
2261
2371
2371

2261
2261
2371
2371

225
225
245
245

237
237
257
257

201
201
205
205

201
201
201
201

v+h
v+h
v+h
v+h

1326
1326
1381
1381

5c
5b
5

1175
1175
1175

2646
2646
2646

2646
2646
2646

279
279
279

292
292
292

201
201
201

205
205
205

v+h
v+h
v+h

1591
1591
1591

6c
6b
6

1320
1320
1320

2881
3061
3061

2881
3061
3061

305
337
337

320
352
352

205
211
211

205
211
211

v+h
v 3) 4)
v 3) 4)

1781
---

7c
7b
7

1465
1465
1465

3206
3206
2994

3206
3206
2994

348
348
418

364
364
434

211
211
232

211
211
235

v 3) 4)
v 3) 4)
v+h

--1910

8b

1610

3139

3139

428

446

232

235

v 4)

----

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

64

mm

60 Hz

UPA 200B, 250C

UPA 200B -- 130 / ..


The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 200B -- 130 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The characteristic curves shown apply to the
standard impeller material, i.e. Noryl.
The performance data for the full impeller diameter
for the given number of stages will only be achieved
when the impellers are made of Noryl (PPO).
For the special impeller material (bronze), please
select the next higher number of stages.
In this case, please refer to the characteristic
curves individually prepared for the quotation.
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 5 / DN 125


The information is based on the model with check
valve / connection branch and threaded end.
The changes in the main dimensions of the flanged
end model are specified in the table below.

Operating range:
Qmin = 24 m3/h
Qmax = End of characteristic curve

Check valve / connection branch with:


Threaded
end G5

Flanged end
DN 125

Length
mm

Length
mm

Outside dia.
mm

200

150 (PN 10/16)


150 (PN 25/40)

250
270

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to DIN EN 1092--2.
Optimum impeller dia. d

Maximum impeller dia.

65

60 Hz

UPA 200B, 250C

UPA 250C -- 120 for Well Diameters of 250 mm (10 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

UPA 250C -- 120/.. + ...

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature
of the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and +30 _C)

Ho
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1l
1h
1f
1d
1

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

13/21
18/21
18/21
22/21
26/21

42.5
50.2
53.7
58.8
62.5

15.5
20.0
22.0
25.0
29.0

20.8
26.8
29.5
33.5
38.9

34
35
32
36
38

29.0
37.0
40.5
45.5
52.0

81.4
83.1
82.7
84.6
85.6

0.83
0.82
0.83
0.82
0.83

4 x 2.5
4 x 4.0
4 x 4.0
4 x 4.0
4 x 6.0

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 4.0 4)

2l
2k
2h
2f
2d
2

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 200D
+ UMA 200D

26/21
30/21
37/22
37/22
45/21
55/21

82.6
90.4
97.6
104.3
114.6
122.3

31.2
36.0
42.0
44.0
52.0
60.0

41.8
48.3
56.3
59.0
69.7
80.5

35
35
47
44
31
32

55.0
64.0
76.0
78.0
89.0
101.0

85.4
85.6
85.1
84.9
85.7
86.8

0.84
0.83
0.83
0.84
0.87
0.86

4 x 6.0
4 x 6.0
3/4 x 4.0 II 3)
3/4 x 4.0 II 3)
4 x 10.0
4 x 16

3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)

3h
3f
3d
3

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D

55/21
65/21
65/21
90/21

144.5
156.3
169.1
181.0

62.0
68.0
76.0
90.0

83.1
91.2
101.9
120.7

31
33
30
33

105.0
115.0
126.0
156.0

86.8
87.6
87.6
88.2

0.86
0.85
0.87
0.83

4 x 16
3/4 x 10 II 3)
3/4 x 10 II 3)
3/4 x 16 II 3)

3/4 x 6.0 4)
3/4 x 10 4)
3/4 x 10 4)
3/4 x 16 4)

4f + UMA 200D 90/21


4d + UMA 250D 110/21
4 + UMA 250D 132/21

208.7
229.9
243.8

95.0
105.0
120.0

127.4
140.8
160.9

32
34
35

162.0
181.0
200.0

88.2
88.6
89.3

0.84
0.83
0.85

3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 25 II 3)

3/4 x 16 4)
3/4 x 25 4)
3/4 x 25 4)

5d + UMA 250D 132/21


5 + UMA 250D 160/21

286.0
304.0

130.0
150.0

174.3
201.2

33
32

214.0
247.0

89.3
89.7

0.86
0.85

3/4 x 25 II 3)
3/4 x 25 II 3)

3/4 x 25 4)
3/4 x 35 4) 5)

366.3

180.0

241.4

32

304.0

90.2

0.83

3/4 x 35 II 3) 5)

+ UMA 250D 190/21

7
1)
2)
3)
4)
5)
6)
7)

+ UMA 300D 250/22

434.6

215.0

288.3

62

359.0

89.6

0.84

3/3x70 II + 1x35

3) 6)

3/4 x 35 4) 5)
6x95 + 1x50 4) 7)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax in mm

Installation 2)

UPA 250C -- 120/..

mm

Standard

Special

Standard

Special

D.o.l.

Y-

1l
1h
1f
1d
1

681
681
681
681
681

1510
1600
1600
1690
1795

1510
1600
1600
1690
1795

123
131
131
139
148

135
143
143
151
160

230
230
230
230
232

232
232
232
232
233

v+h
v+h
v+h
v+h
v+h

751
796
796
841
893

2l
2k
2h
2f
2d
2

828
828
828
828
828
828

1942
2042
2122
2122
2059
2169

1942
2042
2122
2122
2059
2169

169
178
185
185
238
258

185
194
201
201
254
274

232
232
233
233
235
238

233
233
233
233
235
235

v+h
v+h
v 3)
v 3)
v+h
v+h

1040
1090
--1099
1154

3h
3f
3d
3

975
975
975
975

2316
2446
2446
2716

2316
2446
2446
2716

278
301
301
349

299
322
322
370

238
235
235
244

235
239
239
244

v+h
v+h
v+h
v 3)

1301
1366
1366
--

4f
4d
4

1122
1122
1122

2863
2651
2781

2863
2651
2781

369
439
483

394
464
508

244
246
257

244
257
257

v 3)
v+h
v+h

-1542
1607

5d
5

1269
1269

2928
3038

2928
3038

503
540

532
569

257
257

257
266

v+h
v 4)

1754
--

1416

3335

3335

611

644

266

280

v 3) 4)

--

1563

3636

3636

757

794

304

304

v 4)

--

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

66

mm

60 Hz

UPA 200B, 250C

UPA 250C -- 120 / ..


The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 250C -- 120 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 6 / DN 150


The information is based on the model with check
valve / connection branch and threaded end.
The changes in the main dimensions of the flanged
end model are specified in the table below.
Check valve / connection branch with:
Threaded
end G6

Flanged end
DN 150

Length
mm

Length
mm

Outside dia.
mm

229

179 (PN 10/16)


179 (PN 25/40)

285
300

Threaded end to DIN ISO 228, Part 1.

Operating range:
Qmin = 24 m3/h
Qmax = End of characteristic curve

Flange mating dimensions to DIN EN 1092--2.

Optimum impeller dia. f

Maximum impeller dia.

250

400

67

60 Hz

UPA 200B, 250C

UPA 250C --150 for Well Diameters of 250 mm (10 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump
Discharge
head
Q = 0 m3/h

UPA 250C -- 150/.. + ...

Motor lead 2), flat

Motor
Rated
power

Max. temperature
of the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and +30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1l
1k
1d
1

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

18/21
22/21
30/21
37/22

39.1
46.3
55.9
59.6

19.0
24.0
33.0
38.0

25.5
32.2
44.3
51.0

36
37
38
49

36.0
44.0
60.0
69.0

83.2
84.7
85.8
85.4

0.81
0.81
0.81
0.81

4 x 4.0
4 x 4.0
4 x 6.0
3/4 x 4.0 II 3)

3/4 x 2.5 4)
3/4 x 2.5 4)
3/4 x 4.0 4)
3/4 x 4.0 4)

2k
2h
2f
2c
2

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D

45/21
55/21
55/21
65/21
65/21

92.5
99.2
106.8
113.8
117.7

48.0
54.0
60.0
68.0
76.0

64.4
72.4
80.5
91.2
101.9

32
35
32
34
30

83.0
93.0
101.0
115.0
126.0

85.7
86.7
86.8
87.6
87.6

0.86
0.85
0.86
0.85
0.87

4 x 10
4 x 16
4 x 16
3/4 x 10 II 3)
3/4 x 10 II 3)

3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 10 4)
3/4 x 10 4)

3h
3g
3d
3b
3

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 250D
+ UMA 250D

75/21
90/21
90/21
110/21
110/21

143.2
151.4
162.6
172.1
176.5

80.0
90.0
100.0
110.0
120.0

107.3
120.7
134.1
147.5
160.9

31
34
31
33
31

136.0
156.0
169.0
188.0
203.0

87.5
88.2
88.2
88.7
88.7

0.85
0.83
0.85
0.83
0.84

3/4 x 10 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)

3/4 x 10 4)
3/4 x 16 4)
3/4 x 16 4)
3/4 x 25 4)
3/4 x 25 4)

4e
4c
4b
4

+ UMA 250D 132/21


+ UMA 250D 132/21
+ UMA 250D 160/21
+ UMA 250D 160/21

213.0
221.9
229.3
235.1

125.0
135.0
145.0
155.0

167.6
181.0
194.4
207.9

34
32
33
31

207.0
222.0
241.0
254.0

89.3
89.3
89.7
89.6

0.85
0.86
0.85
0.86

3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)

3/4 x 25 4)
3/4 x 25 4)
3/4 x 35 4) 5)
3/4 x 35 4) 5)

5d + UMA 250D 190/21


5b + UMA 250D 190/21
5 + UMA 300D 250/22

276.2
287.2
300.9

170.0
180.0
200.0

228.0
241.4
268.2

34
32
62

291.0
304.0
341.0

90.2
90.2
89.3

0.82
0.83
0.83

3/4 x 35 II 3) 5)
3/4 x 35 II 3) 5)
3/3x70 II + 1x35 3) 6)

3/4 x 35 4) 5)
3/4 x 35 4) 5)
6x95 + 1x50 5) 7)

6b + UMA 300D 250/22

350.5

225.0

301.7

61

373.0

89.8

0.85

3/3x70 II + 1x35 3) 6)

6x95 + 1x50 5) 7)

1)
2)
3)
4)
5)
6)
7)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax in mm

Installation 2)

UPA 250C -- 150/..

mm

Standard

Special

Standard

Special

D.o.l.

Y-

1l
1k
1d
1

690
690
690
690

1609
1699
1904
1984

1609
1699
1904
1984

129
137
156
163

141
149
168
175

230
230
232
233

232
232
233
233

v+h
v+h
v+h
v 3)

800
845
947
--

2k
2h
2f
2c
2

846
846
846
846
846

2077
2187
2187
2317
2317

2077
2187
2187
2317
2317

235
255
255
278
278

250
270
270
293
293

235
238
238
235
235

235
238
235
239
239

v+h
v+h
v+h
v+h
v+h

1112
1167
1167
1232
1232

3h
3g
3d
3b
3

1002
1002
1002
1002
1002

2563
2743
2743
2531
2531

2563
2743
2743
2531
2531

313
345
345
415
415

331
363
363
433
433

239
244
244
246
246

239
244
244
257
257

v+h
v 3)
v 3)
v+h
v+h

1433
--1417
1417

4e
4c
4b
4

1158
1158
1158
1158

2817
2817
2927
2927

2817
2817
2927
2927

478
478
515
515

499
499
536
536

257
257
257
257

257
257
266
266

v+h
v+h
v+h
v+h

1638
1638
1693
1693

5d
5b
5

1314
1314
1314

3233
3233
3387

3233
3233
3387

584
584
709

609
609
734

266
266
304

280
280
304

v 3) 4)
v 3) 4)
v 4)

----

6b

1470

3543

3543

728

757

304

304

v 4)

--

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

68

mm

60 Hz

UPA 200B, 250C

UPA 250C -- 150 / ..


The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 250C -- 150 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 6 / DN 150


The information is based on the model with check
valve / connection branch and threaded end.
The changes in the main dimensions of the flanged
end model are specified in the table below.
Check valve / connection branch with:
Threaded
end G 6

Flanged end
DN 150

Length
mm

Length
mm

Outside dia.
mm

229

179 (PN 10/16)


179 (PN 25/40)

285
300

Threaded end to DIN ISO 228, Part 1.

Operating range:
Qmin = 36 m3/h
Qmax = End of characteristic curve

Flange mating dimensions to DIN EN 1092--2.

Optimum impeller dia. g

Maximum impeller dia.

250

400

69

60 Hz

UPA 200B, 250C

UPA 250C -- 250 for Well Diameters of 250 mm (10 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump
Discharge
head
Q = 0 m3/h

UPA 250C -- 250/.. + ...

Motor lead 2), flat

Motor
Rated
power

Max. temperature of
the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and +30 _C)

H0
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1m
1k
1f
1

+ UMA 150D
+ UMA 150D
+ UMA 150D
+ UMA 150D

26/21
26/21
30/21
37/22

37.8
42.1
47.0
54.7

29.0
31.2
36.0
44.0

38.9
41.8
48.3
59.0

37
35
35
44

52.0
55.0
64.0
78.0

85.6
85.4
85.6
84.9

0.83
0.84
0.83
0.84

4 x 6.0
4 x 6.0
4 x 6.0
3/4 x 4.0 II 3)

3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)
3/4 x 4.0 4)

2m
2l
2g
2e
2c
2

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D

55/21
55/21
65/21
65/21
90/21
90/21

73.7
80.3
89.0
96.1
104.2
108.0

58.0
62.0
70.0
76.0
85.0
90.0

77.8
83.1
93.9
101.9
114.0
120.7

33
31
33
31
34
33

99.0
105.0
118.0
126.0
149.0
156.0

86.8
86.8
87.6
87.6
88.1
88.2

0.86
0.86
0.86
0.87
0.82
0.83

4 x 16
4 x 16
3/4 x 10 II 3)
3/4 x 10 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)

3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 10 4)
3/4 x 10 4)
3/4 x 16 4)
3/4 x 16 4)

3h
3f
3d
3

+ UMA 200D 90/21


+ UMA 250D 110/21
+ UMA 250D 132/21
+ UMA 250D 132/21

125.8
136.5
149.8
159.0

100.0
110.0
120.0
135.0

134.1
147.5
160.9
181.0

31
33
35
32

169.0
188.0
200.0
222.0

88.2
88.7
89.3
89.3

0.85
0.83
0.85
0.86

3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)

3/4 x 16 4)
3/4 x 25 4)
3/4 x 25 4)
3/4 x 25 4)

4f
4e
4c
4

+ UMA 250D 160/21


+ UMA 250D 160/21
+ UMA 250D 190/21
+ UMA 250D 190/21

181.9
190.4
205.9
213.4

145.0
150.0
170.0
180.0

194.4
201.2
228.0
241.4

34
32
34
32

241.0
247.0
291.0
304.0

89.7
89.7
90.2
90.2

0.85
0.85
0.82
0.83

3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 35 II 3) 5)
3/4 x 35 II 3) 5)

3/4 x 35 4) 5)
3/4 x 35 4) 5)
3/4 x 35 4) 5)
3/4 x 35 4) 5)

5e + UMA 250D 190/21


5b + UMA 300D 250/22

238.5
264.4

190.0
220.0

254.8
295.0

31
62

317.0
367.0

90.2
89.7

0.84
0.84

3/4 x 35 II 3) 5)
3/3x70 II + 1x35 3) 6)

3/4 x 35 4) 5)
6x95 + 1x50 4) 7)

1)
2)
3)
4)
5)
6)
7)

Also see pages 3 and 55


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

mA in kg

Installation 2)

Standard

Special

Standard

Special

D.o.l.

Y-

1m
1k
1f
1

709
709
709
709

1823
1823
1923
2003

1823
1823
1923
2003

146
147
156
163

154
155
164
171

232
232
232
233

233
233
233
233

v+h
v+h
v+h
v 3)

896
896
946
--

2m
2l
2g
2e
2c
2

884
884
884
884
884
884

2225
2225
2355
2355
2625
2625

2225
2225
2355
2355
2625
2625

255
255
278
278
326
326

266
266
289
289
337
337

238
238
235
235
244
244

235
235
239
239
244
244

v+h
v+h
v+h
v+h
v 3)
v 3)

1185
1185
1250
1250
---

3h
3f
3d
3

1059
1059
1059
1059

2800
2588
2718
2718

2800
2588
2718
2718

345
415
459
459

359
429
473
473

244
246
257
257

244
257
257
257

v 3)
v+h
v+h
v+h

-1454
1519
1519

4f
4e
4c
4

1234
1234
1234
1234

3003
3003
3153
3153

3003
3003
3153
3153

515
515
566
566

533
533
584
584

257
257
266
266

266
266
280
280

v 4)
v 4)
v 3) 4)
v 3) 4)

-----

5e
5b

1409
1409

3328
3482

3328
3482

585
710

606
731

266
304

280
304

v 3) 4)
v 4)

---

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

70

Dmax in mm

mm

UPA 250C- 250/..

1)
2)
3)
4)

LA mm

mm

60 Hz

UPA 200B, 250C

UPA 250C -- 250 / ..


The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 250C -- 250 /..


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 6 / DN 150


The information is based on the model with check
valve / connection branch and threaded end.
The changes in the main dimensions of the flanged
end model are specified in the table below.
Check valve / connection branch with:
Threaded
end G 6

Flanged end
DN 150

Length
mm

Length
mm

Outside dia.
mm

229

179 (PN 10/16)


179 (PN 25/40)

285
300

Threaded end to DIN ISO 228, Part 1.

Operating range:
Qmin = 60 m3/h
Qmax = End of characteristic curve

Flange mating dimensions to DIN EN 1092--2.

Optimum impeller dia. h

Maximum impeller dia.

250

400

71

60 Hz

72

UPA 200B, 250C

UPA 300, 350

60 Hz
Application

Submersible Borehole Pumps

Handling clean or slightly contaminated water in applications


such as:
-- general water supply
-- irrigation and spray irrigation
-- pressure boosting
-- lowering and maintaining ground water levels as well as
-- drainage

for Well Diameters


of 300 mm (12 inches) and Above
and of 350 mm (14 inches) and Above
Single-entry and mixed flow

Also used in mining, sprinkler installations, fountains etc.


Permissible sand content in the fluid handled: 50 g/m3.
Also suitable for aggressive seawater if supplied in material
variant C3 (duplex).

Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 1080 m3/h (300 l/s
or up to 4000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 474 m
Temperature of fluid handled . . t

up to +50 C

Speed . . . . . . . . . . . . . . . . . . . . . n

3500 rpm

Design
Single or multistage, single-entry centrifugal pump in
ring-section design. For vertical and horizontal installation.
Mixed flow hydraulic systems with impellers that can be turned
down. Stage casings are connected by means of stud bolts.
Suction casing fitted between pump and motor. Suction casing
equipped with strainer to protect the pump from coarse
particles in the fluid.
Pumps with check valve or connection branch on option. Both
models with threaded or flanged end.
Particularly suitable for vertical installation in narrow deep wells.

Designation (Example)
UPA 300 -- 94 / 5 b
Available automation products:

Type series
Minimum well diameter (mm)

Hyamaster
(for UPA 300)

(for ex.: 300 mm = 12 inches)

Capacity Qopt at 50 Hz (l/s)


Number of stages
Reduced impeller diameter(s)

Certification
Quality management certified to ISO 9001

Product Features
---------

Very sturdy design


Suitable for installation in narrow deep wells
High efficiency
Motor designed for maximum pump output
Low noise level
For vertical or horizontal installation
Non-return valve protected against blocking
Pre-filled motor; no risk of contamination of the handled
water

73

UPA 300, 350

60 Hz
Selection Chart (Ranges on Offer)

n 3500 rpm

UPA 300 -- 94
UPA 300 -- 65

UPA 350 -- 128

UPA 350 -- 180

UPA 300 -- 65
UPA 350 -- 180
UPA 300 -- 94

UPA 350 -- 128

Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this range. The operating
ranges QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages.
74

UPA 300, 350

60 Hz
Material Variants

Type of Installation

G (Standard)

B (Special)

C3 (Duplex)

Cast iron
(JL 1030 5) ) /
Nodular cast
iron 1)
(JS--1030 6) )

Bronze
(CC480K--GS) /
Aluminium
bronze 1)
(CC333G--GS)

CrNiMo steel
(1.4517)

Pump
Casing

Impeller
Shaft
Wear ring
Bearings

Screws,
bolts and
nuts 2)

Bronze (CC480K--GS)
Cr steel
(1.4021)

CrNiMo steel
(1.4517)

CrNiMo steel
(1.4462)

high-performance plastics
Cr steel
(1.4021)
/ carbon

CrNiMo steel
(1.4462)
CrNiMo steel
(1.4138)

Drive
Type . . . . . . . . . . . . . . . . water-filled submersible
squirrel-cage motor, 2-poles
Type of enclosure . . . . IP 68
Frequency . . . . . . . . . . . 60 Hz
Type of current . . . . . . . three-phase (3~)
Rated voltage U . . . . . . 440 V ... 460 V
Rated power PN . . . . . . up to 415 kW (556.5 hp)

Aluminium
bronze
(CC308G--R750)
/ carbon

CrNiMo steel
(A4--70)

In general, the pumps are installed vertically. Some models


may also be installed horizontally, depending on the number of
stages and motor size.

SiC / SiC

CrNiMo steel
(1.4462)

Frequency of starts . . . 10 / h 1) and 5 / h 2)


Minimum delay
before re-starting . . . . . 3 min
Motor design is in compliance with VDE regulations.
1)
2)

G (Standard)

C2 (Special)

C3 (Duplex)

motor
Shaft

UMA 200D and 250D motors


UMA 300D motor and larger motors

Connection to Power Supply

CrNiMo steel (1.4462)

Casing

Cast iron
(JL-1030 5) /
JL 1040 4) 7) )

CrNiMo steel
(1.4408 3) /
1.4517 4) )

CrNiMo steel
(1.4539 3) /
(1.4517 4) )

The submersible motors are supplied ex factory with 1 or 2


motor leads, each equipped with an earth conductor. All motors
are provided with internal earthing.

Stator
case

CrNi steel
(1 4301)
(1.4301)

CrNiMo steel
(1 4571 3) /
(1.4571
1.4462 4) )

CrNiMo steel
(1 4539 3) /
(1.4539
1.4462 4) )

Any extension cables required are connected using water-tight


cable connectors.

Screws,
bolts and
nuts 2)

CrNiMo steel
(1.4539 3) /
1.4462 4) )

CrNiMo steel (A4-70)

1) For large number of stages


2) In contact with fluid handled
3) for motors UMA 200D and. UMA
4) for motors UMA 300D only

250D only

5)
6)
7)

DIN mat. code: GG-20


DIN mat. code: GGG-40
DIN mat. code: GG-25

Bearings / Lubrication
Radial plain bearings: pump bearings lubricated by the fluid
handled, motor bearings by the motors water fill. Depending on
the pump size and number of stages, 1 or 2 intermediate
bearings are fitted in the pump.
Axial thrust is balanced by a tilting-pad thrust bearing in the
motor (lower end).

Direction of Rotation of the Pump


Clockwise rotation (when looking at the drive shaft end).

Pump End (Discharge Nozzle)


Optionally with internal thread G 6 and G 8 or flange DN 150
to DN 250, depending on pump size.

Coating (Standard)
Quality . . . . . . . . . . . . . . 2-component high-build coating
(epoxy resin base), approved for
drinking water contact
Coating structure . . . . . Primer and top coat
Film thickness . . . . . . . 100 to 150 m
Colour . . . . . . . . . . . . . . ultramarine blue (RAL 5002)

Motor leads and extension cables are suitable for drinking


water applications.

Starting Methods
D.o.l. (autotransformer or soft starter) or star-delta.

Speed Control / Variable Speed


The submersible borehole pumps can also be run at variable
speed to accommodate different operating points.

Application Temperatures
The submersible borehole pumps are, as a standard, suitable
for use in water with temperatures of up to t = +30 C. An
indispensable requirement for this is a flow velocity of
v 0.5 m/s past the motor. This requirement is met, for
example, when the pump is installed in a deep well above the
well screen / filter, etc.
With certain restrictions, some motor sizes may also be used
in water with temperatures of up to t = +50 C or for operation
without an adequate cooling flow of water past the motor, i.e. v
= 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).

Variants Available on Request


-----

Other materials
More wear-resistant designs
Higher supply voltages up to U = 6600 V
Models with cooling, suction or pressure shroud
75

60 Hz

UPA 300, 350

Design Features (UPA 300--94/.. + UMA 250D ../21)

Check valve with anti-blockage


valve disc
-- No jamming or tilting.
-- Spring-loaded design makes for
minimum valve closing times and
prevents waterhammer.
-- High operating reliability.

All wetted plastic components are


approved for drinking water contact
(BAM 1))
-- Coating, electric cables, seal
elements, gaskets, etc. are
absolutely fit for use in drinking
water applications.
1) German Federal Institute for Materials Research

Robust wear rings


-- Replaceable wear rings made of
corrosion- and wear-resistant
metal.
-- Protection against wear in the
clearance; easy servicing.

Enclosed pump bearing


-- No-maintenance design, high wear
resistance.
-- For trouble-free long-term operation.

Stainless steel union elements


-- All wetted bolts, screws and nuts
are made of CrNiMo steel.
-- High operating reliability.
-- Easy to remove and re-use even
after many years of operation.

Mixed-flow impellers
-- Can be turned down. This means
pump performance can be exactly
matched to head requirements in the
system.
Stainless steel pump shaft
-- Fully protected by impeller hubs and
sleeves from direct wear caused by
the fluid handled.

Wear-resistant mechanical
seal
-- Long service life and high
operating reliability.

The KSB motor


-- Efficiencies up to 91 %.
-- VDE-compliant, i.e. high level of
electrical safety.
-- Designed for max. pump power to
protect unit from overloads.

Counter thrust bearing


-- Reliable balancing of negative
axial thrust.
-- Impellers do not rub on the stage
casings.

Dynamically balanced rotor


-- Ensures smooth running.

Tried and tested thrust bearing


-- Water-lubricated self-aligning
tilting-pad journal bearing.
-- No-maintenance design suitable
for maximum load-carrying
capacity under continuous
operation conditions.
-- New materials combination
(stainless steel / carbon) for high
safety factor.

Reliable pressure balancing system


-- Optimum rubber expansion diaphragm
design.
-- Enables installation at very low depths

3411:10

76

60 Hz

UPA 300, 350

77

UPA 300, 350

60 Hz
UPA 300 -- 65 for Well Diameters of 300 mm (12 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump
Discharge
head

Q=0
UPA 300 -- 65/ ... + ...

Motor lead 2), flat

Motor
Rated
power

m3/h

Max. temperature
of the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and 30 _C)

Ho
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1n
1m
1l
1f
1

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D

37/21
37/21
37/21
45/21
55/21

42.1
49.9
54.5
59.6
69.0

26.0
34.0
38.0
46.0
60.0

34.9
45.6
51.0
61.7
80.5

41
38
35
34
32

49.5
61.0
67.0
80.0
101.0

83.5
84.6
84.8
85.7
86.8

0.79
0.84
0.85
0.85
0.86

4 x 10
4 x 10
4 x 10
4 x 10
4 x 16

3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)

2m
2l
2g
2d
2

+ UMA 200D 65/21


+ UMA 200D 75/21
+ UMA 200D 90/21
+ UMA 250D 110/21
+ UMA 250D 132/21

101.5
111.4
120.4
132.9
142.9

68.0
78.0
95.0
110.0
125.0

91.2
104.6
127.4
147.5
167.6

34
31
32
33
34

115.0
134.0
162.0
188.0
207.0

87.6
87.5
88.2
88.7
89.3

0.85
0.84
0.84
0.83
0.85

3/4 x 10 II 3)
3/4 x 10 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 25 II 3)

3/4 x 10 4)
3/4 x 10 4)
3/4 x 16 4)
3/4 x 25 4)
3/4 x 25 4)

3k
3h
3e
3d
3

+ UMA 250D 132/21


+ UMA 250D 160/21
+ UMA 250D 160/21
+ UMA 250D 190/21
+ UMA 300D 250/22

171.4
179.9
189.2
199.9
218.8

130.0
145.0
155.0
170.0
200.0

174.3
194.4
207.9
228.0
268.2

33
34
32
34
63

214.0
241.0
254.0
291.0
341.0

89.3
89.7
89.6
90.2
89.3

0.86
0.85
0.86
0.82
0.83

3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 35 II 3) 5)
3/3x70 II + 1x35 3) 6)

3/4 x 25 4)
3/4 x 35 4) 5)
3/4 x 35 4) 5)
3/4 x 35 4) 5)
6x95 + 1x50 4) 7)

4g
4e
4b
4

+ UMA 300D 250/22


+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 250/22

248.3
258.0
276.7
289.9

200.0
215.0
240.0
265.0

268.2
288.3
321.8
355.4

63
62
61
59

341.0
359.0
394.0
429.0

89.3
89.6
90.0
90.2

0.83
0.84
0.85
0.86

3/3x70 II + 1x35 3)6)


3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

5e + UMA 300D 250/22


5b + UMA 300D 250/22
5 + UMA 300D 300/22

320.9
344.0
362.4

265.0
295.0
330.0

355.4
395.6
442.5

59
57
59

429.0
471.0
534.0

90.2
90.4
90.8

0.86
0.87
0.86

3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

6c + UMA 300D 300/22


6 + UMA 300D 400/22

408.4
432.9

345.0
390.0

462.7
523.0

58
57

554.0
622.0

90.9
91.1

0.86
0.87

6x95 II + 1x50 3) 7)
6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

7c + UMA 300D 400/22

474.6

400.0

536.4

56

634.0

91.1

0.87

6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)

1)
2)
3)
4)
5)
6)
7)

Also see pages 3 and 75


3/4 = 1 x 3-core + 1 x 4-core. flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax mm

Installation 2)

UPA 300 - 65/ ..

mm

Standard

Special

Standard

Special

D.o.l

Y-

1n
1m
1l
1f
1

735
735
735
735
735

1876
1876
1876
1966
2076

1876
1876
1876
1966
2076

213
213
213
229
249

224
224
224
240
260

269
269
269
269
271

276
276
276
276
276

v+h
v+h
v+h
v+h
v+h

946
946
946
991
1046

2m
2l
2g
2d
2

900
900
900
930
930

2371
2461
2641
2459
2589

2371
2461
2641
2459
2589

304
320
352
430
474

319
335
367
446
490

276
275
278
278
289

275
275
278
289
289

v+h
v+h
v 3)
v+h
v+h

1276
1321
-1335
1400

3k
3h
3e
3d
3

1095
1095
1095
1095
1095

2754
2864
2864
3014
3168

2754
2864
2864
3014
3168

506
543
543
594
747

526
563
563
614
770

289
289
289
298
325

289
298
298
311
325

v+h
v+h
v+h
v 3) 4)
v 4)

1565
1620
1620
---

4g
4e
4b
4

1260
1260
1260
1260

3333
3333
3333
3333

3333
3333
3333
3333

779
779
779
779

806
806
806
806

325
325
325
325

325
325
325
325

v 4)
v 4)
v 4)
v 4)

-----

5e
5b
5

1425
1425
1425

3498
3498
3678

3498
3498
3678

811
811
889

842
842
920

325
325
304

325
325
304

v 4)
v 4)
v 4)

----

6c
6

1590
1590

3843
3963

3843
3963

921
973

956
1008

304
304

304
304

v 4)
v 3) 4)

---

7c

1755

4128

4128

1005

1044

304

304

v 3) 4)

--

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

78

mm

60 Hz

UPA 300, 350

UPA 300 -- 65 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 300 -- 65

(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 6 / DN 150


The information is based on the model with check
valve and threaded end.
The changes in the main dimensions of the flanged
end model or the model with connection branch
are specified in the table below.
a) Check valve with:
Threaded end
G 6

Flanged end
DN 150

Length
mm

Length
mm

Outside dia.
mm

255

220 (PN 10/16)


228 (PN 25/40)

285
300

b) Connection branch with:


Threaded end
G 6

Operating range:
Qmin = 60 m3/h
Qmax = End of characteristic curve

Flanged end
DN 150

Length
mm

Length
mm

Outside dia.
mm

150

140 (PN 10/16)


148 (PN 25/40)

285
300

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.

Maximum
impeller dia.
Optimum impeller dia. b

79

UPA 300, 350

60 Hz
UPA 300 -- 94 for Well Diameters of 300 mm (12 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

UPA 300 -- 94/ ... + ...

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature
of the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and +30 _C)

Ho
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1n
1m
1k
1g
1d
1

+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D
+ UMA 200D

45/21
55/21
55/21
65/21
75/21
90/21

49.0
54.5
62.5
68.1
73.4
78.7

48.0
56.0
62.0
72.0
80.0
95.0

64.4
75.1
83.1
96.6
107.3
127.4

32
34
31
32
31
32

83.0
96.0
105.0
120.0
136.0
162.0

85.7
86.8
86.8
87.6
87.5
88.2

0.86
0.85
0.86
0.86
0.85
0.84

4 x 10
4 x 16
4 x 16
3/4 x 10 II 3)
3/4 x 10 II 3)
3/4 x 16 II 3)

3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 6.0 4)
3/4 x 10 4)
3/4 x 10 4)
3/4 x 16 4)

2m
2k
2h
2d
2

+ UMA 250D 110/21


+ UMA 250D 132/21
+ UMA 250D 160/21
+ UMA 250D 190/21
+ UMA 300D 250/22

113.3
131.7
139.7
153.4
167.1

110.0
130.0
145.0
170.0
200.0

147.5
174.3
194.4
228.0
268.2

32
33
34
34
63

188.0
214.0
241.0
291.0
341.0

88.7
89.3
89.7
90.2
89.3

0.83
0.86
0.85
0.82
0.83

3/4 x 16 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 35 II 3) 5)
3/3x70 II + 1x35 3) 6)

3/4 x 25 4)
3/4 x 25 4)
3/4 x 35 4) 5)
3/4 x 35 4) 5)
6x95 + 1x50 4) 7)

3k
3h
3e
3c
3

+ UMA 300D 250/22


+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 250/22

205.5
216.8
230.7
240.0
251.5

200.0
220.0
235.0
265.0
295.0

268.2
295.0
315.1
355.4
395.6

63
62
61
59
57

341.0
367.0
386.0
429.0
471.0

89.3
89.7
89.9
90.2
90.4

0.83
0.84
0.85
0.86
0.87

3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

4f + UMA 300D 300/22


4c + UMA 300D 300/22
4 + UMA 300D 400/22

300.9
319.4
335.2

315.0
350.0
390.0

422.4
469.4
523.0

59
57
57

513.0
562.0
622.0

90.7
90.9
91.1

0.85
0.86
0.87

6x95 II + 1x50 3) 7)
6x95 II + 1x50 3) 7)
6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

5e + UMA 300D 400/22

382.2

390.0

523.0

57

622.0

91.1

0.87

6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)

1)
2)
3)
4)
5)
6)
7)

Also see pages 3 and 75


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax mm

Installation 2)

A
mm

UPA 300 - 94/ ..

mm

Standard

Special

Standard

Special

D.o.l

Y-

1n
1m
1k
1g
1d
1

775
775
775
775
775
775

2006
2116
2116
2246
2336
2516

2006
2116
2116
2246
2336
2516

253
273
273
296
312
344

268
288
288
311
327
359

279
281
281
286
285
288

286
286
286
285
285
288

v+h
v+h
v+h
v+h
v+h
v 3)

1006
1061
1061
1126
1171
--

2m
2k
2h
2d
2

980
980
980
980
980

2509
2639
2749
2899
3053

2509
2639
2749
2899
3053

450
494
531
582
731

471
515
552
603
755

288
299
299
308
331

299
299
308
321
331

v+h
v+h
v+h
v 3)
v 4)

1360
1425
1480
---

3k
3h
3e
3c
3

1155
1155
1155
1155
1155

3228
3228
3228
3228
3228

3228
3228
3228
3228
3228

764
764
764
764
764

793
793
793
793
793

331
331
331
331
331

331
331
331
331
331

v 4)
v 4)
v 4)
v 4)
v 4)

------

4f
4c
4

1330
1330
1330

3583
3583
3703

3583
3583
3703

875
875
927

909
909
961

311
311
311

311
311
311

v 4)
v 4)
v 3) 4)

----

5e

1505

3878

3878

960

999

311

311

v 3) 4)

--

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

80

UPA 300, 350

60 Hz
UPA 300 -- 94 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 300 -- 94

(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve.
Pump efficiency
p:
(not considering check valve).
NPSH:
Net positive suction head
required by the pump.

Pump End G 8 / DN 200


The information is based on the model with check
valve and threaded end.
The changes in the main dimensions of the flanged
end model or the model with connection branch
are specified in the table below.
a) Check valve with:
Threaded end
G 8

Flanged end
DN 200

Length
mm

Length
mm

Outside dia.
mm

290

240 (PN 10)


240 (PN 16)
244 (PN 25)

340
340
360

b) Connection branch with:


Threaded end
G 8

Operating range:
Qmin = 84 m3/h
Qmax = End of characteristic curve

Flanged end
DN 200

Length
mm

Length
mm

Outside dia.
mm

200

134 (PN 10)


134 (PN 16)
138 (PN 25)

340
340
360

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.

Optimum
impeller dia. b
Maximum
impeller dia.

385

81

UPA 300, 350

60 Hz
UPA 350 -- 128 for Well Diameters of 350 mm (14 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

UPA 350 -- 128/ ... + ...

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

Max. temperature
of the fluid handled
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and 30 _C)

Ho
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1l
1k
1h
1f
1d
1b
1

+ UMA 200D 55/21


+ UMA 200D 75/21
+ UMA 200D 90/21
+ UMA 250D 110/21
+ UMA 250D 132/21
+ UMA 250D 160/21
+ UMA 250D 190/21

56.9
65.8
74.9
83.2
91.9
100.0
109.0

60.0
78.0
100.0
115.0
135.0
155.0
185.0

80.5
104.6
134.1
154.2
181.0
207.9
248.1

32
32
31
32
32
31
31

101.0
134.0
169.0
195.0
222.0
254.0
311.0

86.8
87.5
88.2
88.7
89.3
89.6
90.2

0.86
0.84
0.85
0.84
0.86
0.86
0.83

4 x 16
3/4 x 10 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 35 II 3) 5)

3/4 x 6.0 4)
3/4 x 10 4)
3/4 x 16 4)
3/4 x 25 4)
3/4 x 25 4)
3/4 x 35 4) 5)
3/4 x 35 4) 5)

2h
2g
2e
2c
2b
2

+ UMA 300D 250/22


+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 300/22
+ UMA 300D 300/22

154.9
162.6
174.6
189.0
204.1
220.4

205.0
220.0
245.0
280.0
315.0
360.0

274.9
295.0
328.6
375.5
422.4
482.8

62
62
60
58
59
57

347.0
367.0
400.0
450.0
513.0
575.0

89.5
89.7
90.1
90.3
90.7
91.0

0.83
0.84
0.86
0.87
0.85
0.87

3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
6x95 II + 1x50 3) 7)
6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

3c + UMA 300D 400/22

282.3

415.0

556.5

56

658.0

91.1

0.87

6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)

1)
2)
3)
4)
5)
6)
7)

Also see pages 3 and 75


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

LA mm

mA in kg

Dmax mm

Installation 2)

A
mm

UPA 350 -- 128/ ..

mm

Standard

Special

Standard

Special

D.o.l

Y-

1l
1k
1h
1f
1d
1b
1

898
898
898
898
898
898
898

2239
2459
2639
2427
2557
2667
2817

2239
2459
2639
2427
2557
2667
2817

289
328
360
432
476
513
564

308
347
379
452
496
533
584

316
320
324
324
334
334
343

322
320
324
334
334
343
357

v+h
v+h
v 3)
v+h
v+h
v+h
v 3)

1119
1229
---1213
1278
1333
----

2h
2g
2e
2c
2b
2

1108
1108
1108
1108
1108
1108

3181
3181
3181
3181
3361
3361

3181
3181
3181
3181
3361
3361

764
764
764
764
842
842

793
793
793
793
871
871

360
360
360
360
341
341

360
360
360
360
341
341

v 4)
v 4)
v 4)
v 4)
v 4)
v 4)

-------------------

3c

1308

3681

3681

936

970

341

341

v 3) 4)

----

1)
2)
3)
4)

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

82

UPA 300, 350

60 Hz
UPA 350 -- 128 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 350 -- 128


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 8 / DN 200 1)


The information is based on the model with check
valve and threaded end.
The changes in the main dimensions of the flanged
end model or the model with connection branch
are specified in the table below.
a) Check valve with:
Threaded end
G 8

Flanged end
DN 200

Length
mm

Length
mm

Outside dia.
mm

328

278 (PN 10)


278 (PN 16)

340

b) Connection branch with:


Threaded end
G 8

Flanged end
DN 200

Length
mm

Length
mm

Outside dia.
mm

169

123 (PN 10)


123 (PN 16)

340

Operating range:
Qmin = 120 m3/h
Qmax = End of characteristic curve

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.
1)

DN 250 check valve (with flanged


end only) on request. For relevant head
losses see HV curve plotted over Q.

Optimum
impeller dia. c
Maximum impeller dia.

448
365 -- pedestals for motor
440 -- pedestals for pump

83

UPA 300, 350

60 Hz
UPA 350 -- 180 for Well Diameters of 350 mm (14 inches) and Above
Pumps with submersible motors for ...
Pump unit

-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V


-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)

Pump

UPA 350 -- 180/ ... + ...

Motor lead 2), flat

Motor

Discharge
head
Q = 0 m3/h

Rated
power

of the fluid handled


Max. temperature
v 0.5 m/s

Rated
current

Efficiency

Power
factor

Number x cross-section of
conductors (use under water,
460 V and 30_C)

Ho
m

PN
kW

PN
hp

tmax 1)
_C

IN
A

M
%

cos
----

D.o.l.
mm2

Y-
mm2

1m
1l
1h
1e
1c
1

+ UMA 200D 90/21


+ UMA 250D 110/21
+ UMA 250D 110/21
+ UMA 250D 132/21
+ UMA 250D 160/21
+ UMA 250D 190/21

59.3
66.0
71.0
80.8
89.7
96.3

95.0
110.0
115.0
135.0
150.0
175.0

127.4
147.5
154.2
181.0
201.2
234.7

32
33
31
32
33
33

162.0
188.0
195.0
222.0
247.0
297.0

88.2
88.7
88.7
89.3
89.7
90.2

0.84
0.83
0.84
0.86
0.85
0.82

3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 16 II 3)
3/4 x 25 II 3)
3/4 x 25 II 3)
3/4 x 35 II 3) 5)

3/4 x 16 4)
3/4 x 25 4)
3/4 x 25 4)
3/4 x 25 4)
3/4 x 35 4) 5)
3/4 x 35 4) 5)

2k
2g
2f
2d
2b
2

+ UMA 300D 250/22


+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 250/22
+ UMA 300D 300/22
+ UMA 300D 300/22

141.7
149.9
164.3
177.6
189.0
198.2

230.0
245.0
265.0
290.0
320.0
360.0

308.4
328.6
355.4
388.9
429.1
482.8

61
60
59
57
59
57

381.0
400.0
429.0
463.0
521.0
575.0

89.9
90.1
90.2
90.4
90.8
91.0

0.85
0.86
0.86
0.87
0.85
0.87

3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
3/3x70 II + 1x35 3) 6)
6x95 II + 1x50 3) 7)
6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)
6x95 + 1x50 4) 7)

3f + UMA 300D 400/22

244.5

405.0

543.1

56

642.0

91.1

0.87

6x95 II + 1x50 3) 7)

6x95 + 1x50 4) 7)

1)
2)
3)
4)
5)
6)
7)

Also see pages 3 and 75


3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
2 cables in parallel.
Delta wiring in the cable connector or control cabinet.
1 x 3--core flat + 1 x 4--core round.
2 x 3--core flat + 1 x 1--core round.
6 x 1--core round + 1 x 1--core round.

Dimensions / Weights / Horizontal Installation 1)


LP

mA in kg

Installation 2)

mm

Standard

Special

Standard

Special

D.o.l

Y-

898
898
898
898
898
898

2639
2427
2427
2557
2667
2817

2639
2427
2427
2557
2667
2817

360
432
432
476
513
564

379
452
452
496
533
584

324
324
324
334
334
343

324
334
334
334
343
357

v 3)
v+h
v+h
v+h
v+h
v 3)

---1213
1213
1278
1333
----

2k
2g
2f
2d
2b
2

1108
1108
1108
1108
1108
1108

3181
3181
3181
3181
3361
3361

3181
3181
3181
3181
3361
3361

764
764
764
764
842
842

793
793
793
793
871
871

360
360
360
360
341
341

360
360
360
360
341
341

v 4)
v 4)
v 4)
v 4)
v 4)
v 4)

-------------------

3f

1308

3681

3681

936

970

341

341

v 3) 4)

----

Including check valve with threaded end and standard motor leads.
v = vertical; h = horizontal.
Horizontal installation on request.
Horizontal installation only with bearing pedestals of special design.

84

Dmax mm

1m
1l
1h
1e
1c
1

UPA 350 - 180/ ..

1)
2)
3)
4)

LA mm

mm

UPA 300, 350

60 Hz
UPA 350 -- 180 /..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.

UPA 350 -- 180


(Tolerances to
ISO 9906 Class 2)

Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv :
Head losses in the check valve
p:
Pump efficiency
(not considering check valve)
NPSH:
Net positive suction head
required by the pump

Pump End G 8 / DN 200 1)


The information is based on the model with check
valve and threaded end.
The changes in the main dimensions of the flanged
end model or the model with connection branch
are specified in the table below.
a) Check valve with:
Threaded end
G 8

Flanged end
DN 200

Length
mm

Length
mm

Outside dia.
mm

328

278 (PN 10)


278 (PN 16)

340

b) Connection branch with


Threaded end
G 8

Flanged end
DN 200

Length
mm

Length
mm

Outside dia.
mm

169

123 (PN 10)


123 (PN 16)

340

Operating range:
Qmin = 144 m3/h
Qmax = End of
characteristic curve

Threaded end to DIN ISO 228, Part 1.


Flange mating dimensions to
DIN EN 1092--2.
1)

DN 250 check valve (with flanged


end only) on request. For relevant head
losses see HV curve plotted over Q.

448
365 -- pedestals for motor
440 -- pedestals for pump

85

60 Hz

86

UPA 300, 350

60 Hz
Applications

BSX, BSF
Submersible Borehole Pumps

Transport of pure and natural water for ...


-- general water procuring and supplying,
-- irrigation and sprinkling,
-- ground-water lowering and maintaining in open-work
mining,
-- water maintaining and draining of galleries in underground
mining.

for Well Diameters


of 400 mm (16 inches) and Above
single-flow and mixed-flow

In addition in pressure-boosting plants and sprinkler


installations as well as in offshore and cavern technologies etc.
Admissible contents of sand in the liquid handled: 50 g/m3.

Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 2200 m3/h (610 l/s
or up to 10,000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 240 m
Temperature of liquid handled . t

up to + 50 oC

Speed . . . . . . . . . . . . . . . . . . . . . n

1750 rpm

Design
Single- or multi-stage, single-flow centrifugal pumps in
ring-section design. For vertical, angled and horizontal
installation. Mixed-flow hydraulics with reducibles impellers.
The stage casings are connected by means of studs.
Suction casing between pump and motor with suction strainer
as protection of pump against coarse impurities of the liquid
handled.
Pump end at choice with non-return valve or connection nozzle.
Either design with flanged connection.
Especially suitable for installation in narrow deep wells.

Designation
B

Z S

Type series
Design status
Minimum well diameter (mm) 1)
Suction impeller
Code for hydraulics (50 Hz)
Number of stages
Impellers reduced
1)

X = 400 mm (16 inches), Y = 450 mm (18 inches),


Z = 500 mm (20 inches), E = 600 mm (24 inches),
F = 650 mm (26 inches)

Certification

Quality management certified to ISO 9001

535 / 5 a

Product Features
---------

Very sturdy design


Suitable for installation in narrow deep wells
High efficiency
Motor designed for maximum pump output
Low noise level
For vertical or horizontal installation
Non-return valve protected against blocking
Pre-filled motor without risk of contamination of the pumped
water

87

BSX, BSF

60 Hz
Selection Chart (Ranges on Offer)

U.S.gpm

1000

n 1750 rpm

1400

Imp.g.p.m. 1000

2000
1400

4000

3000
2000

3000

6000
4000

10000
6000

10000

700
2000
500
400
1000

300

BRY 504

H
m
200

BRZS 535

BRE 555

BSX 463

BSF 586

500

150

400
100
80

300
H
ft

60

200

50
40
100

30

80
20

60

15
40
10
200
40

60

300
80

400
100

500

Q m3/h

Q l/s

200

1000
300

2000
400

600

3000
800
3430:80

88

60 Hz
Materials
Component

Drive
Execution G

Execution B

Cast iron JL1030


(GG-20)

Bronze (G-CuSn10)

Pump ...
Casing
Impeller
Shaft

Bronze (G-CuSn10)
Cr steel (1.4021)

Wear rings
Bearings

BSX, BSF

CrNiMo steel
(1.4462)

KSB submersible motors DN 300 and above in squirrel-cage


design, three-phase current (3~), 4 poles. For low (U = 1000 V)
and high (U = 6000V) voltage. Water-filled motor. The water fill
lubricates the bearings and cools the windings sealed with
water-tight insulation material. The shaft is sealed by lip seals
protected against ingress of sand or a mechanical seal.
Pressure differences between motor and environment are
equalized by a rubber expansion diaphragm in the motor.
Construction complies with VDE regulations.

Bronze (2.1090)
Cr steel (1.4021)
annealed /
special bronze

Component

Alu bronze
(G-CuAl11Ni) /
special bronze

Execution G

Motor ...
Shaft
Cast parts

Steel (C 45) enclosed


Cast iron JL1030 (GG-20)

Stator jacket

Steel (St 37)

Electrical Connection
The motors are equipped ex works with 2 short cables.
Generally with earthing.
Connection of extension cable by means of a waterproof cable
connector. At choice connection of the complete cable length
direct at the winding in the submersible motor.
Short cable and extension cable for low voltage (U 1000 V)
in food quality.

Starting Methods
Bearings / Lubrication
Pump:
1 radial plain bearing in suction casing and in bearing bracket
housing resp. in last stage (BSF 586). Dependent on pump size
and number of stages additionally 1 intermediate bearing.
Lubricated by the liquid handled.
Motor:
2 radial plain bearings and 1 thrust bearing with tilting pads for
balancing of axial thrust. Lubricated by the motor fill water.

Low voltage (U 1000 V): direct on line (without or with starting


transformer as well as with smooth running device) and
star-delta.
High voltage (U > 1000 V): only direct on line.

Application Temperatures
The submersible units are so designed as to allow also
operation without additional cooling in the motor area, e.g.
installation in a deep well, in a big tank etc. (the liquid handled
does not stream directly along the motor).

Right-handed, i.e. clockwise rotation


(viewed at the drive shaft end).

With additional cooling, e.g. installation in the deep well above


the filter area, execution with cooling shroud etc. (the liquid
handled streams along the motor with v 0.5 m/s), the
submersible units can be used in water of elevated
temperatures (additionally 5 C and more).

Pump End (Discharge Nozzle)

Designs on Request

Direction of Rotation of the Pump

Flange DN 200 up to DN 400 dependent on pump size.

Coating (Standard)
Quality . . . . . . . . . . . 2-component high-build coating
(epoxy resin base), approved for
drinking water contact
Structure . . . . . . . . . Primer and top coat
Thickness of coat . 100 to 150 m.

---------

other material designs


higher temperatures of liquid handled
higher voltages until 6600 V
other frequencies
more wear resistant design
with cooling, suction or pressure shroud
special coating
motor in special design (solidly/sealed against high
pressure, flameproof, etc.)

Colour . . . . . . . . . . . ultramarine blue (RAL 5002).

Mode of Installation
Generally vertical installation. Dependent on number of stages
and the motor size also horizontal installation possible.

89

BSX, BSF

60 Hz
Design Features

The coating and the cable in food


quality (BAM)1)
-- For use without any problems in
drinking water area.

The non-return valve with doubleguided valve plate


-- No jamming or canting.
-- With valve plate spring loaded.
Thus allows minimum closing-times
and avoids consequently
waterhammers.

1) German federal inst. for materials


research

The enclosed pump bearing


-- Maintenance-free and extensively
protected against wear.
-- Long-term operation without
problems.

The steadfast wear rings


-- Replaceable rings (standardly with
casing and impeller wear ring) out of
wear- and corrosion-resistant metal.
-- They protect against gap wear and
allow easy servicing.

The mixed-flow impellers


-- Reducibles. Thus caused optimum
adaptation to need of pump heads.
-- With keys for reliable power
transmission and simplified
dismantling and mounting.

The pump shaft out of stainless


steel
-- Completely protected by means of
sleeves against direct wear
caused by the liquid handled.

Stainless steel union elements


-- All screws and nuts of superior alloy
steel (CrNiMo).
-- That is a guarantee for a high degree
of functional reliability and a
considerably simplified dismantling.

The motor KSB


-- Acc. to VDE standards, i.e. a high
level of electric safety.
-- Designed for max. possible pump
power consumption and thus
protected against overload.

The dynamically balanced rotor


-- It ensures an optimum quietness
of running.

The counter thrust bearing


-- It balances the negative axial thrust.
-- Thus it prevents reliably butting of the
impellers against the stage casings.

The reliable pressure balancing


system
-- Optimum design of rubber
diaphragm.
-- Therefore largest possible
immersion depths.

The proven thrust bearing


-- Water-lubricated plain bearing with
self-adjusting tilting pads.
-- This allows absolutely
maintenance-free operation and
maximum loads under continuous
duty conditions.
3411:11

90

60 Hz
Applications
Handling clean and raw water in applications such as:
-- general water extraction / supply,
-- irrigation and spray irrigation,
-- lowering and maintaining ground water levels in open-cast
mines,
-- dewatering and gallery drainage in underground mines.

UPZ

Submersible Borehole Pumps


for Well Diameters
of 500 mm (20 inches) and Above
Double entry, back-to-back impeller arrangement

Use in pressure-boosting and sprinkler systems, as well as for


offshore and cavern applications, etc.
Permissible sand content in the fluid handled: 50 g/m3.

Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 2200 m3/h (612 l/s
or up to 10,000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 1500 m
Supply voltage . . . . . . . . . . . . . . U up to 6600 V
Temperature of fluid handled . . t

up to +40 oC

Speed . . . . . . . . . . . . . . . . . . . . . n

3500 rpm and 1750 rpm

Design
Multistage, double-entry ring-section pump with back-to-back
impeller arrangement. For vertical installation. Radial and
mixed-flow hydraulic systems with impellers that can be turned
down.
Half the flow enters the pump through the lower suction casing,
the other half through the upper suction casing. The upper half
of the pump unit is surrounded by a pump shroud (outer shell).
The two flows are collected by the channel created by the
shroud and carried into the upper suction casing, which is
equipped with two discharge branches. This design
theoretically ensures full axial thrust balancing. The casing
components (stage casings) are connected by means of round
tie bolts. The two suction casings are equipped with strainers
to protect the pump from coarse particles in the fluid. Flanged
pump end. Check valve with flanged end available on request.
Particularly suitable for installation in narrow deep wells.

Pump Designation (Example)


UPZ

160 -- 228 / 8

Type series
Capacity Qopt (l/s)
Nominal impeller diameter (mm)
Number of stages

Certification
Quality management certified to ISO 9001

91

UPZ

60 Hz
Selection Chart (Ranges on Offer)

U.S.gpm

n 3500 rpm and n 1750 rpm

500

1000

200 Imp. g. p. m. 500

2000
1000

5000
2000

2000

10000
5000
6000

UPZ ...

1500

5000
4000

1000

n = 1450 1/min

3000

H
m

2000

500

H
ft

400
300

1000

n = 2900 1/min

800
700

200

600
500

150

400
100

300

200
50
40
50

100
20

30

Q m3/h

200
50

300

400 500
100

Q l/s

1000
200

300

2000
500

3470:1

Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this flow range.

92

60 Hz

UPZ

Materials

Coating (Standard)

The choice of materials depends on the capacity and


discharge head.

For cast iron models only.

Component
Pump
Casing

Impeller/
Diffuser

Cast iron (GJL-200)


Nodular cast iron (GJS-600)
Bronze (CuSn10)
Aluminium bronze (CuAl10Ni)
CrNi steel
Bronze (CuSn10)
Aluminium bronze (CuAl10Ni)
CrNi steel

Shaft

CrNi steel (1.4057)


CrNiMo steel (1.4462)

Wear ring

Aluminium bronze (CuAl10Ni)


CrNiMo steel

Bearings

Screws, bolts
and nuts 1)

Chrome steel (1.4021), hard chrome


plated / special bronze or other
special materials
CrNiMo steel

Motor

Quality . . . . . . . . . . . . . . 2-component high-build coating


(epoxy resin base), approved for
drinking water contact.
Coating structure . . . . . Primer and top coat
Film thickness . . . . . . . 100 to 150 m
Colour . . . . . . . . . . . . . . ultramarine blue (RAL 5002)

Type of Installation
In general, the pumps are installed vertically.

Drive
KSB submersible squirrel-cage motor, 2 or 4 poles.
Three-phase current (3~).
For supply voltages up to U = 6600 V. Water-filled motor. The
water fill lubricates the bearings and cools the windings sealed
with water-tight insulation material. Internal cooling circuit. The
shaft is sealed by lip seals or a mechanical seal protected from
ingress of sand. Pressure differences between motor and
environment are equalized by a rubber expansion diaphragm
in the motor.

Shaft

Steel (1.0503+N), protected

Cast parts

Cast iron (GJL-200)


Bronze (CuSn10)
Aluminium bronze (CuAl10Ni)
CrNi steel

Motor design is in compliance with VDE regulations.

Stator case

St 37, CrNiMo steel

The motors are supplied ex factory with 1 or 2 motor leads.

Screws, bolts
and nuts 1)

CrNiMo steel

Any extension cables required are connected using cable


connectors. On request, the entire length of cable required can
be connected to the motor at the factory. All motor sizes are
available either with or without earth conductor.

1)

in contact with fluid handled

Bearings / Lubrication
Pump:
1 radial plain bearing in each suction casing. Depending on the
pump size and number of stages, 1 additional intermediate
bearing each in the two pump halves. Lubricated by the fluid
handled.
Motor:
2 radial plain bearings. Residual axial thrust is balanced by 1
self-aligning tilting-pad thrust bearing in the motor (lower end).
Lubricated by the motors water fill.

Direction of Rotation of the Pump


Clockwise rotation (when looking at the drive shaft end).

Connection to Power Supply

Starting
Low voltage (U 1000 V): d.o.l. (without or with autotransformer
/ with or without soft starter) and star-delta (Y-)starting.
High voltage (U > 1000 V): d.o.l starting only.

Variants Available on Request


-------

Other materials
Higher fluid temperatures
More wear-resistant designs
Models with cooling or pump shroud
Special coating
Special explosion protection up to 6 kV

Pump End (Discharge Nozzle)


With DN 200 to DN 350 flanges to DIN 2526 and 2512,
depending on the pump size.

93

UPZ

60 Hz
Design Features

Robust wear rings


-- Replaceable wear rings made of
wear- and corrosion-resistant metal.
-- Protection against wear in the
clearance; easy servicing.

Enclosed pump bearing


-- No--maintenance design, high wear
resistance.
-- For trouble-free long-term operation.

Pump shroud
-- Slim, low-weight design.
-- High operating reliability because of
simple sealing of high-pressure
section.

Stainless steel pump shaft


-- Fully protected by impeller hubs and
sleeves from direct wear caused by
the fluid handled.

Impellers
-- Can be turned down.
-- This means pump performance can be
matched exactly to head requirements
in the system.

Double-entry design with impellers in


back-to-back arrangement
-- Low wear thanks to low velocities in
the pump and use of special
materials.
-- Designed to ensure full hydraulic
thrust balancing, irrespective of any
wear in the sealing clearances.
-- Considerably reduced load on the
thrust bearing.
-- This allows high discharge heads at
relatively large flow rates.

Stainless steel union elements


-- All wetted bolts, screws and nuts are
made of CrNiMo steel.
-- High operating reliability.

Wear-resistant mechanical seal


-- Long service life and high operating
reliability.

Circulation cooling through double


shroud
-- Low temperature rise

Motor can be filled with drinking water


-- Simply top up whenever needed.

Winding insulation (J2)


-- Cu--VPE--PA material makes for maximum
heat resistance.

Tried and tested thrust bearing


-- New materials combination (stainless steel /
carbon) for high safety factor.
Sealing elements
-- All joints sealed by O-rings. Pressure--proof
up to a differential pressure of 16 bar.

94

High efficiency M
-- Reduced operating costs thanks to
optimized windings.

Optimized cooling pump


-- No peak temperatures.

Reliable pressure balancing system


-- Optimum selection thanks to
generously sized rubber diaphragm.
-- Enables installation at very low
depths.

60 Hz

Submersible Borehole Pumps

Typical Tender for S 100D


No.

Q
Quantity
i

Item

Unit p
price
E
Euro

Amount
E
Euro

Submersible borehole pump(s) type S 100D


for well diameters of 100 mm (4 inches) and above
Make:
KSB
Pump + motor: S 100D -- . . . . . . / . . . . . + . . . . . . . . . . . . . . kW
Multistage centrifugal pump for vertical / angled / horizontal 1) installation. Integrated, check valve with double-guided valve disc. Plain bearing lubricated by
the fluid handled and protected against ingress of sand. Discharge nozzle with
threaded end.
Submersible canned motor for three-phase current, with self--aligning thrust
bearing, expansion diaphragm for pressure equalization and cable kit
1.5 / 2.5 1) m power supply cable.
Max. permissible submergence below maximum water level: 350 m.
Fluid handled: clean or slightly contaminated water with a permissible sand
content of up to 50 g/m3!
Outer pump casing, suction casing and
check valve housing . . . . . . . . . . . . . . . . . . . . . . . .
Stage casing (diffuser) . . . . . . . . . . . . . . . . . . . . .
Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shaft (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bearing (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor (shaft and housing) . . . . . . . . . . . . . . . . . .
Capacity . . . . . . . . . . . . . . . .
Head . . . . . . . . . . . . . . . . . . .
Temperature (fluid handled)
Rated power (motor) . . . . . .
Speed / Frequency . . . . . . .
Voltage / Starting . . . . . . . . .
Pump end . . . . . . . . . . . . . . .
Outside diameter . . . . . . . . .
Pump set length / weight . .

Q =
H =
t =
PN =
n
U =
G
Dmax=
LA

CrNi steel
glass fibre reinforced NORYL
glass fibre reinforced NORYL
Chrome steel
Rubber
CrNi steel
m3/h /

kW /
rpm / f =
V/
d.o.l.
11/4 (DN 32) / 2 (DN 50) 1)
mm / GA

l/s
m
oC
hp
Hz

mm
kg

Adapter from G 11/4 to R 11/2 .


to flanged end DN
.
Adapter from threaded end G
Pair of supporting and installation clamps for risers
R11/4 (DN 32) / R2 (DN 50)1).
Cooling shroud with suction strainer and pedestals for horizontal
installation.
Power supply cable
x
mm2, separate/connected 1), length
m.
1)
Cable connector, separable / non-separable , with sealing compound,
motor supply cable not connected and sealed/connected and sealed1)
at the factory.
Cable tie
UPA CONTROL box for 3 / 400 V with thermal overcurrent relay with phase
failure protection, temperature-compensated, insulating enclosure, with
3 electrodes and integrated Dry running protection / Water level control
selector switch.
Motor contactor for 1 / 230 V with ON/OFF switch for automatic operation,
insulating enclosure.
Dry running protection equipment:
-- for semi-automatic operation with 2 1)
-- for fully automatic operation with 3 1)
control current lines with a length of
m each.
Lightning protection with earthing terminal for 3 400 V.
Automatic control unit Controlmatic E / Cervomatic EDP1).
Sum total
1) Delete

as applicable

95

60 Hz

Submersible Borehole Pumps

Typical Tender UPA 100C


No.

Qty

Unit p
price

Item

Submersible borehole pump(s) type UPA 100C for well diameters of


100 mm (4 inches) and above.
Marke:
Pump + motor:

KSB
UPA 100C --

Multistage centrifugal pump for vertical / angled / horizontal 1) installation.


Components of stainless steel with a minimum wall thickness of 1 mm and vanes
welded at 6 points. Integrated check valve. Generously dimensioned plain
bearing lubricated by the fluid handled. Discharge nozzle with threaded end.
Submersible canned motor for three-phase current, with self--aligning thrust
bearing, expansion diaphragm for pressure equalization and cable kit
1.5 / 2.5 1) m power supply cable.
Max. permissible submergence below maximum water level: 350 m.
Fluid handled:

clean or slightly contaminated water with a permissible


sand content of up to 50 g/m3.

Suction and discharge casing . . . . . . . . . . . . . . . CrNi steel


Diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel
Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel
Shaft (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel
Bearing (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . Rubber
Motor (shaft and housing) . . . . . . . . . . . . . . . . . . CrNi steel
m3/h /
l/s
Capacity . . . . . . . . . . . . . . . . . . . Q =
Head . . . . . . . . . . . . . . . . . . . . . . H =
m
Temperature (fluid handled) . . . t =
C
Rated power (motor) . . . . . . . . . PN=
kW /
hp
Speed / Frequency . . . . . . . . . . n
rpm / f =
Hz
Voltage / Starting . . . . . . . . . . . . U =
V/
direct
Pump end . . . . . . . . . . . . . . . . . . Rp
11/2 (DN 40) / 2 (DN 50) 1)
Outside diameter . . . . . . . . . . . . Dmax=
mm
Pump set length / weight . . . . . LA
mm/GA_____kg
Adapter from G

to DN

Pair of supporting and installation clamps


for risers Rp 11/2 (DN 40) / R2 (DN 50)1).
Power supply cable

length

mm2, separate / connected1),


m

Cable connector, separable / non-separable1), with sealing compound,motor


supply cable not connected and sealed / connected and sealed1) at the factory.
Cable tie
UPA CONTROL box for 3~ / 400 V with thermal overcurrent relay with phase
failure protection, temperature-compensated, insulating enclosure, with 3 electrodes and integrated Dry running protection / Water level control selector
switch.
Motor contactor for 1~ / 230 V with ON / OFF switch for automatic operation,
insulating enclosure.
Dry running protection equipment:
-- for semi-automatic operation with 2 1)
-- for fully automatic operation with 3 1)
control current lines with a length of

m each.

Lightning protection with earthing terminal for 3~ 400 V.


Sum total
1)

Delete as applicable

96

Amount

60 Hz

Submersible Borehole Pumps

Typical Tender UPA 200, 200B, 250C


No.

Qty

Unit p
price

Item

Amount

Submersible borehole pump(s) type UPA 200 / 200B / 250C 1)


for well diameters of 200 mm (8 inches) and above.
Make:
Pump + motor:

KSB
UPA

--

Multistage centrifugal pump in ring-section design for vertical / horizontal 1)


installation. Radial or mixed-flow hydraulic systems with impellers that can be turned
down. Pump bearing lubricated by the fluid handled and protected against ingress of
sand. Integrated check valve with anti-blockage, spring-loaded valve disc /
connection branch. Pump end with internal thread / flange 1). Suction casing with
suction strainer fitted between pump and motor.
Pre-filled submersible motor. Three-phase current. Squirrel-cage design with
self-aligning thrust bearing and adequately sized expansion diaphragm for pressure
equalization. Design in compliance with VDE standards. IP 68 enclosure. With power
supply cables. Required flow velocity past the motor: v 0.5 m/s.
Fluid handled:

clean to slightly contaminated water, slightly aggressive / more


aggressive / as specified in water analysis1) , with a permissible
sand content of up to 50 g/m3.

Casings . . . . . . . . . . . . . . . . . . . . . . . . . . . . cast iron / bronze 1)


Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . glass fibre reinforced NORYL/ bronze 1)
(UPA 200/200B) / bronze (UPA 250C)
Wear rings . . . . . . . . . . . . . . . . . . . . . . . . . bronze
Shaft (pump + motor) . . . . . . . . . . . . . . . . Chrome / CrNiMo steel 1)
Stator case (motor) . . . . . . . . . . . . . . . . . . CrNi / CrNiMo steel 1)
Bolts, screws and nuts . . . . . . . . . . . . . . . CrNiMo steel (A4--70)
m3/h /
l/s
Capacity . . . . . . . . . . . . . . . . . . . . . Q =
Head . . . . . . . . . . . . . . . . . . . . . . . . H =
m
m
Shut-off head . . . . . . . . . . . . . . . . . Ho =
% / Motor
%
Efficiency . . . . . . . . . . . . . . . . . . . . Pump
C
Temperature (fluid handled) . . . . . t =
hp / IN =
A
Rated power / amperage . . . . . . . PN =
Speed / Frequency . . . . . . . . . . . . n
rpm / f =
Hz
V
Supply voltage . . . . . . . . . . . . . . . . U =
Starting . . . . . . . . . . . . . . . . . . . . . . . . .
d.o.l.
/
star-delta 1)
Pump end . . . . . . . . . . . . . . . . . . . . G3 (DN 80) / G5 (DN 125) / G6 (DN 150) 1)
mm
Outside diameter . . . . . . . . . . . . . . Dmax=
Economic efficiency analysis (for ex. for 10 years):
Operating period per year approx.
h/
Electricity costs
/kWh. Pump data tolerances to ISO 9906 Class
1. During the acceptance test, the overall efficiency may be max. 3 percentage points
lower than the overall efficiency quoted ( pump x motor).
Adapter, from threaded end G

standard / special 1).

to flange DN

Pair of supporting and installation clamps for riser R / DN 1)


Set of bearing pedestals for horizontal installation without /
tank.
Power supply cable, separate/connected 1),

with1)

mm2, length

.
water storage
m.

Cable connector, size


, with sealing compound, motor supply not connected
and sealed / connected and sealed 1) at the factory.
Cable tie, size

Dry running protection equipment


-- for semi-automatic operation with 2 1)
-- for fully automatic operation with 3 1)
control current lines with a length of

m each.

Temperature monitoring equipment Pt 100 for use in submersible motors to


protect the windings from overheating; it consists of a resistance thermometer with
measuring line and does not include / includes1) a display unit.

Sum total
1) Delete as applicable

97

60 Hz

Submersible Borehole Pumps

Typical Tender for UPA 300, 350


No.

Qty

Unit p
price

Item
Submersible borehole pump(s) type UPA 300 / 350 1)
for well diameters of 300 mm (12 inches) and above.
Make:
Pump + motor:

KSB
UPA

--

Multistage centrifugal pump in ring-section design for vertical / horizontal 1) installation. Mixed flow hydraulic systems with impellers that can be turned down. Pump
bearing lubricated by the fluid handled and protected against ingress of sand. Integrated check valve with anti-blockage, spring-loaded valve disc / connection
branch. Pump end with internal thread / flange 1). Suction casing with suction strainer
fitted between pump and motor.
Pre-filled submersible motor. Three-phase current. Squirrel-cage design with selfaligning thrust bearing and adequately sized expansion diaphragm for pressure
equalization. Design in compliance with VDE standards. IP 68 enclosure. With power
supply cables. Required flow velocity past the motor: v 0.5 m/s.
Fluid handled:

clean to slightly contaminated water, slightly aggressive / more


aggressive / as specified in water analysis1) , with a permissible
sand content of up to 50 g/m3.

Casings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cast iron / bronze 1)


Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze
Wear rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze
Shaft (pump + motor) . . . . . . . . . . . . . . . . . . . . . . . . . Chrome / CrNiMo steel 1)
Stator case (motor) . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNiMo steel
Bolts, screws and nuts . . . . . . . . . . . . . . . . . . . . . . . . CrNiMo steel (A4)
Capacity . . . . . . . . . . . . . . . . . . . . . Q =
m3/h /
l/s
Head . . . . . . . . . . . . . . . . . . . . . . . . H =
m
m
Shut-off head . . . . . . . . . . . . . . . . . Ho =
% / Motor
%
Efficiency . . . . . . . . . . . . . . . . . . . . Pump
C
Temperature (fluid handled) . . . . . t =
hp / IN =
A
Rated power / amperage . . . . . . . PN =
Speed / Frequency . . . . . . . . . . . . n
rpm / f =
Hz
V
Supply voltage . . . . . . . . . . . . . . . . U =
Starting . . . . . . . . . . . . . . . . . . . . . . . . .
d.o.l.
/
star-delta 1)
Pump end . . . . . . . . . . . . . . . . . . . . G6 / G8 / DN 150 / DN 200 / DN 250 1)
mm
Outside diameter . . . . . . . . . . . . . . Dmax=
Economic efficiency analysis (for ex. for 10 years):
Operating period per year approx.
h/
Electricity costs
/kWh. Pump data tolerances to ISO 9906 Class 1.
During the acceptance test, the overall efficiency may be max. 3 percentage points
lower than the overall efficiency quoted ( pump x motor).
Pair of supporting and installation clamps for riser R / DN 1).

Set of bearing pedestals for horizontal installation without / with1) water storage tank.
Power supply cable, separate / connected 1),

mm2,

m length.

Cable connector, size


, with sealing compound, motor supply not connected
and sealed / connected and sealed 1) at the factory.
Cable tie, size

Dry running protection equipment


-- for semi-automatic operation with 2 1)
-- for fully automatic operation with 3 1)
control current lines with a length of

m each.

Temperature monitoring equipment Pt 100 for use in submersible motors to protect the
windings from overheating; it consists of a resistance thermometer with measuring line and
does not include / includes1) a display relay.

Sum total
1)

Delete as applicable

98

Amount

60 Hz

Submersible Borehole Pumps

99

Submersible Motors

60 Hz
Submersible Motors for Well Diameters
of 100 mm (4 inches) and above

DN 100, 150, UMA 150D, 200D, 250D and 300D

Sizes / Connection
DN 100, DN 150, UMA 150D, UMA200D: NEMA standard
UMA 250D, UMA 300D:
KSB standard

Material Variants (Material specifications to EN)


DN 100
Component
All components

G (Standard)
CrNi steel

433
412.53
914.53
550.53
723
710
829
828
829
504
932.52

940.52
271
160.52
900.52
145

DN 150
Component
Shaft
Bearing carrier
Stator case

G (Standard)
CrNi steel
Cast iron (JL1030) 4)
CrNi steel

901.51
550.52

UMA
Components

G (Standard)

C1 (Special)

C3 (Duplex)

914.52
529

Shaft

CrNi steel
(1.4305 2) )

CrNiMo steel
(1.4462 2) )

CrNiMo steel
((1.4462))

382.52

CrNiMo steel(1.4462)
Cast iron
CrNiMo steel
(JL1030 4) /
(1.4408 /
JL 1040 5) 6) )
1.4409 2) /
1.4517 5) )

CrNiMo steel
(1.4539 /
1.4517 5) )

818

Housing

Stator
case
Screws,
bolts and
nuts 3)
2)
3)

CrNi steel
(1.4301)

CrNiMo steel
(1.4571 /
1.4462 5) )

CrNiMo steel
(A4-70)

UMA 150D motors only


Wetted by fluid pumped.

545

CrNiMo steel
( 1.4539 /
1.4462 5) )

81--59
23--2

CrNiMo steel
( 1.4539 /
1.4462 5) )
4)
5)
6)

DIN mat. code: GG-20


UMA 300D motors only
DIN mat. code: GG-25

814
545
382.51

Bearings / Lubrication
Two radial plain bearings as well as a thrust bearing to balance
the pumps axial thrust.
Lubrication by motor fill liquid.

Direction of Rotation of the Motor

529
900.51
940.51
389
932.51
412.51
387
32--2
392
903

384

Anti-clockwise rotation (when looking at the drive shaft end).

Variants Available on Request


-- DN 100: Other supply voltages up to 500 V
-- UMA 150D -- 300D: Other supply voltages up to 1000 V
Part No.
145

Description
Adapter

354
382.51/52
384/387
389

Thrust bearing housing


Bearing carrier (bottom) / (top)
Thrust bearing plate / segment
Counter thrust bearing ring

433
59-12

Mechanical seal
Membrane

529/545.51
81-59
818
828/829.51

Bearing sleeve / Bearing bush


Stator with windings
Rotor
Cable grommet / Cable gland ring

100

412.52
914.51
550.51
59--6
904.52
381
904.51
553
354
484
160.51
500.51

59--42
920.51
916.51
59--12
950
500.52

e.g. UMA 250 D

60 Hz

Submersible Motors

Submersible Motors DN 100, UMA 150D to 300D: 3~, n 3500 1/min, d.o.l. + Y-
IN

PN

cos

Cu

3~

(submerged)

Standard

460 V

4/4

4/4

d.o.l.

Y-

kW

hp

--

mm2

mm2

0.59
0.83
1.0
1.4
1.8
2.5
3.4
4.2
6.4
8.6

0.8
1.1
1.3
1.9
2.4
3.4
4.5
5.6
8.6
11.6

1.5
2.1
2.4
3.1
4.1
5.6
7.4
8.7
13.1
17

70
73
72
74
74
77
79
78
78
78

0.76
0.74
0.79
0.82
0.80
0.77
0.76
0.79
0.82
0.82

4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5

-------------------------------

5/21
7/21
9/21
13/21
15/21
18/21
22/21
26/21
30/21
37/22

6.6
9
11.2
15.6
18
22.2
26.4
31.2
36
44

9
12.2
15.2
21.2
24.5
30.2
35.9
42.4
49
59.8

13.4
17.5
21.2
28.9
32.5
40.2
47.2
54.8
63.8
77.4

76
77.5
79
82
83
83
85
85.5
86
85.5

0.82
0.84
0.84
0.83
0.84
0.84
0.83
0.83
0.83
0.84

4 x 2.5
4 x 2.5
4 x 2.5
4 x 2.5
4 x 4.0
4 x 4.0
4 x 4.0
4 x 6.0
4 x 6.0
3/4 x 4.0 2)

3/4 x 2.5
3/4 x 2.5
3/4 x 2.5
3/4 x 2.5
3/4 x 2.5
3/4 x 2.5
3/4 x 2.5
3/4 x 4.0
3/4 x 4.0
3/4 x 4.0

37/21
45/21
55/21
65/21
75/21
90/21

45
55
66
77
90
118

61
75
90
105
122
161

78
94
112
129
153
167

86
87
88
88.5
88
89

0.85
0.85
0.85
0.84
0.84
0.84

3/4 x 10 2)
3/4 x 6 2)
3/4 x 6 2)
3/4 x 10 2)
3/4 x 10 2)
3/4 x 16 2)

3/4 x 10
3/4 x 6
3/4 x 6
3/4 x 10
3/4 x 10
3/4 x 16

85/21
110/21
132/21
160/21
190/21

102
132
158
192
228

138
180
215
261
310

169
218
258
312
369

88
88.5
89
89.5
89.5

0.86
0.86
0.86
0.87
0.87

3/4 x 10 II
3/4 x 25 2)
3/4 x 25 2)
3/4 x 25 II
3/4 x 35 II

3/4 x 16
3/4 x 25
3/4 x 25
3/4 x 35
3/4 x 50

210 3)
250 3)
280 3)
310 3)
350 3)
400 3)

386
340
381
422
476
544

339
403
446
494
553
622

89
89.5
90
90.5
91.5
91.5

0.88
0.87
0.88
0.87
0.87
0.88

3/4 x 35 II
3/4 x 35 II
3/4 x 50 II
3/3 x 70 II
3/3 x 70 II
7 x 1 x 95 II

3/4 x 35
3/4 x 35
3/4 x 50
2 x 3 x 70
2 x 3 x 70
7 x 1 x 95

Motor size

L
1~

mm

3~

Standard

1~

mm

3~
kg

DN 100 ...
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.7
5.5
7.5

96

242
271
299
327
356
460
-------------

223
242
271
299
327
356
423
552
704
780

8.3
9.6
10.8
13.5
14.4
18.0
-------------

7.3
8.3
9.6
10.8
12.1
13.5
16.0
22.5
29.0
33.0

143

-------------------------------

699
719
749
829
874
919
1009
1114
1214
1294

-------------------------------

48
50
53
58
62
67
76
87
97
101

189

-------------------

1140
1230
1340
1470
1560
1740

-------------------

130
145
165
187
203
235

232

----------------

1419
1529
1659
1769
1919

----------------

260
295
340
390
428

282

-------------------

1808
1908
2038
2108
2208
2308

-------------------

535
575
645
680
720
780

UMA 150D ...


UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 150D
UMA 200D ...
UMA 200D
UMA 200D
UMA 200D
UMA 200D
UMA 200D
UMA 200D
UMA 250D ...
UMA 250D
UMA 250D
UMA 250D
UMA 250D
UMA 250D

UMA 300D ...


UMA 300D
UMA 300D
UMA 300D
UMA 300D
UMA 300D
UMA 300D

180/22
210/22
250/22
280/22
310/22
350/22

2) -wiring of the 2 standard short cables for d.o.l. starting in the cable connector or in the control box.
3) Leistungsreduzierung fr Y -- Einschaltung

Additional motor data:


Frequency of starts . . . . . . . . . . . . . . . . . . . . . . . . . . 100 20/h
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 150D: 15/h
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 200D/250D: 10/h
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D 280/22: 10/h
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D 310/22: 5/h
Horizontal installation . . . . . . . . . . . . . . . . . . DN 100: all sizes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 150D: 30/21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 200D: 75/21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 250D: 160/21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D: 310/22

Motor cable:
DN 100: L = 1.5 m ( 1.5 kW) / 2.5 m (> 1.5 kW), 1 x
DN 150: L = 4 m, 1 x
or 2 x
UMA 150D: L = 4 m, 1 x
or 1 x
+1x
UMA 200B: L = 6 m, 1 x
+1x
UMA 250B: L = 6 m, 1 x
+1x
or
1x
+1x
( 35 mm2)
UMA 300D: L = 10m, 1 x
+1x
or
2x
(70 mm2) + 1 x
(35 mm2) or
6x
+1x
(95 mm2)
Other cables on request.
101

60 Hz

Accessories

Accessories
Description
Cable

Connector
size 28
Plug

Ident. No.

Electric extension cable1), blue, rubber-sheathed cable for submerged


operation in drinking water applications, ambient temperatures t +50 oC.
-- Cable kit, 4-core, round, only for pump sets with three-phase
current (3~) motors, DN 100,
L= 5m
G RD GWT - J - 4G 1.5 (4 x 1.5 mm2) with earth conductor
Consisting of: 1 plug,
10 m
2.5 m cable, 1 cable connector size 28
15 m
and additional cable lengths.
20 m
25 m
30 m
35 m
40 m
-- Cable kit, 4-core, round,
G RD GWT - J 4G 1.5 (4 x 1.5 mm2) . . . per m
with earth conductor
4G 2.5 (4 x 2.5 mm2) . . . . . . . . . .
4G 4.0 (4 x 4.0 mm2) . . . . . . . . . .
4G 6.0 (4 x 6.0 mm2) . . . . . . . . . .
4G 10 (4 x 10 mm2) . . . . . . . . . . .
4G 16 (4 x 16 mm2) . . . . . . . . . .
4G 25 (4 x 25 mm2) . . . . . . . . . . .
4G 35 (4 x 35 mm2) . . . . . . . . . . .
4G 50 (4 x 50 mm2) . . . . . . . . . . .
4G 70 (4 x 70 mm2) . . . . . . . . . . .
-- Cable kit, 3-core, flat,
G FL GWT - O 3 x 1.5 mm2 . . . . . . . . . . . per m
without earth conductor
3 x 2.5 mm2 . . . . . . . . . . . . . . . .
3 x 4.0 mm2 . . . . . . . . . . . . . . . . .
3 x 6.0 mm2 . . . . . . . . . . . . . . . . .
3 x 10 mm2 . . . . . . . . . . . . . . . . . .
3 x 16 mm2 . . . . . . . . . . . . . . . . . .
3 x 25 mm2 . . . . . . . . . . . . . . . . . .
3 x 35 mm2 . . . . . . . . . . . . . . . . . .
3 x 50 mm2 . . . . . . . . . . . . . . . . . .
3 x 70 mm2 . . . . . . . . . . . . . . . . . .
For selection see details and examples on pages 106 -- 109.
Shielded Hydrofirm (T) cable
Shielded Hydrofirm (T) cable
Shielded Hydrofirm (T) cable

S07BC4B--F 3x6/6KON
S07BC4B--F 3x16/16KON
S07BC4B--F 3x35+3G16/3

Standard cable connector with heat shrink tube, non--separable.


-- 4 x 1.5 mm2 and 4 x 2.5 mm2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- As above, but connected and sealed at the factory . . . . . . . . . . . . . . . . . . .
-- 4 x 4 mm2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- As above, but connected and sealed at the factory . . . . . . . . . . . . . . . . . . .
Cable connector, separable, including sealing compound,
size 25, only for pump sets with 3~ motors, DN 100,
for connecting 1 extension cable to ...
1 motor lead . . . . . . . . . . . . . . . . . . . -- not including connection
-- including connection
Note: Can only be supplied together with the pump set.
Separately available:
-- Short cable:
1.5 m long, 4 x 1.5 mm2, with plug and cable joint
2.5 m long, 4 x 1.5 mm2, with plug and cable joint
-- Cable joint:
for 1 x 4 x 1.5 mm2, flat, or up to 1 x 4 x 4 mm2, round
1)

For permissible cable lengths see pages 108 and 109.

102

kg

01 045 633
01 045 634
01 045 635
01 045 636
01 045 637
01 045 638
01 045 639
01 045 640

1.55
2.45
3.35
4.25
5.15
6.05
6.95
7.85

01 046 056
01 046 057
01 046 058
01 046 059
01 046 060
01 046 061
01 046 062
01 046 063
01 046 064
01 050 669

0.180
0.259
0.356
0.475
0.837
1.220
1.770
2.304
3.185
4.364

01 046 038
01 046 039
01 046 040
01 046 041
01 046 042
01 046 043
01 046 044
01 046 045
01 046 046
01 046 047

0.110
0.171
0.252
0.319
0.486
0.750
1.107
1.438
2.054
2.760

01 083 423
01 083 424
01 083 425
40 980 058
40 980 708
39 020 537
39 020 536

0.1
0.1
0.1
0.1

90 033 494 0.6


90 039 543 0.6

00 117 947 0.4


01 025 739 0.7
00 117 792 0.2

60 Hz

Accessories

Accessories
Description
Cable connector, non-separable, including sealing compound,
for connecting 1 extension cable to 1 or 2 motor leads
-- Size 28 for connecting 1 extension cable to ...
1 motor lead . . . . . . . . . . . . . . . . . -- supplied, but not connected
-- connected and sealed at the factory .
-- Size 35 for connecting 1 extension cable to ...
1 motor lead . . . . . . . . . . . . . . . . . -- supplied, but not connected
-- connected and sealed at the factory
-- Size 43 for connecting 1 extension cable to ...
a) 1 motor lead . . . . . . . . . . . . . . -- supplied, but not connected
-- connected and sealed at the factory
b) 2 motor lead
-- supplied, but not connected
-- connected and sealed at the factory .
Sizes 53 to 78 available on request.
For selection see details and examples on page 110.

3300:236/2

Size 1

Ident. No.

Size 2

Cable tie for fastening power supply cable to riser


-- Size 1
(rubber strap / plastic studs),
for cable sizes up to 1 FL 3 x 6 mm2 or 4 x 6 mm2 and 1 RD 4 x 6 mm2 .
-- Sizes 2 -- 11
(metal strap / screw band with tension screw / rubber cable protector),
for larger cross-sections up to 70 mm2 available on request
Note: Cable ties for pump sets of material variants Standard B and Special
on request.
Note: Use 1 cable tie each per cable and per 3 m of riser pipe.
For selection see details and examples on page 111.
UPA CONTROL box 3~ / 400 V,
for d.o.l. starting, temperature-compensated, insulating enclosure, with 4
PG cable glands for round cable, 3 immersion electrodes and integrated
selector switch for Dry running protection or Water level control
operation, as well as with thermal overcurrent relay with phase failure
protection, for motor sizes ...
1~/230 V:
3~/400 V:
-----0.37 kW
-----0.55 kW + 0.75 kW
-----1.10 kW + 1.50 kW
0.37 + 0.55 kW
-----0.75 kW
2.20 kW
1.10 kW
3.00 kW + 3.7 kW
1.50 kW
2.2 kW
5.50 kW
-----7.50 kW
-----UMA 150D - 5/21
-----UMA 150D - 7/21
-----UMA 150D -- 9/21
Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode per m

Automatic control units


Cervomatic EDP
with G 11/4 connection, for a max. flow rate of 12 m3/h,
3
Cervomatic EDP max. flow rate of 12 m /h, a max. operating pressure of 10 bar and a max.
current rating of 10 A,
for 1~ + 3~/ 220 to 240 V and 3~/ 380 to 415 V
(with electric protection from 0 to 10 A, can be set in 0.5 A steps).

Controlmatic E

Controlmatic E
with G 11/4 connection, for a max. flow rate of 10 m3/h, a max. operating
pressure of 10 bar and a max. current rating of 10 A,
for 1~ 220 to 240 V

kg

95 005 106 0.45


90 049 385 0.45
90 049 397 0.5
90 049 387 0.5
90 049 399
90 049 389
90 049 400
90 049 390

0.55
0.55
0.55
0.55

90 006 993

0.04

------

------

40 980 887
3.5
40 980 889
3.5
40 980 891
3.5
40 980 893
3.5
40 980 895
3.5
40 980 897
3.5
40 980 899
3.5
40 984 811
3.5
90 052 649
3.5
40 984 811
3.5
90 052 649
3.5
90 052 650
3.5
01 046 306 0.051
90 053 396 2.2

90 053 395 1.3

Dry running protection equipment for ...


-- semi-automatic operation (1 relay, 1 pushbutton + 2 electrodes) . . . . . . .
-- fully automatic operation (1 relay + 3 electrodes) . . . . . . . . . . . . . . . . . . . .

90 009 553
90 009 554

Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode

01 046 306 0.051

per m

Pressure controller, (membrane-type), insulating enclosure . . . . . . . . . . . . .


1 -- 10 bar, with R 3/8 connection.

01 088 101

2.0
2.0

0.9

103

60 Hz

Accessories

Accessories
Description

Ident. No.

kg

90 052 823

0.5

..........
..........
..........
..........
..........

90 050 611
95 000 220
95 000 221
95 000 232
95 000 233

3.0
3.5
3.5
9.4
5.6

Pair of supporting and installation clamps for the following riser sizes ...
incl. screws, bolts and nuts, -- R 11/4 / DN 32, L = 600 mm, F = 11.8 kN
for installation / dismantling
-- R 2 / DN 50, L = 600 mm, F = 17.5 kN
ofvertical submersible
--R 2 1/2 / DN 65 L = 600 mm, F = 17.5 kN
pump sets in /
-- R 3 / DN 80, L = 600 mm, F = 17.5 kN
from wells, tanks, etc.
-- R 4 / DN 100 L = 700 mm, F = 24.5 kN
Material: Steel, painted.
-- R 5 / DN 125 L = 800 mm, F = 31.0 kN
-- R 6 / DN 150 L = 800 mm, F = 31.0 kN
-- R 8 / DN 200 L = 900 mm, F = 108 kN

95 000 290
95 000 294
95 000 296
95 000 298
95 000 300
95 000 302
95 000 304
95 000 307

7.5
11.5
12.0
12.0
21.0
29.0
29.0
70.0

01 117 821
90 017 255
01 046 640
01 061 866
01 061 867
01 061 868
01 061 869
01 061 870
01 046 644
01 046 645
01 046 646
01 053 905
01 053 906
01 053 907

1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7.8
7.8
8.0
16.0
16.0
17.2

Adapter from threaded end G 11/4 to threaded end G 11/2 . . . . . . . . . . .


Material: CrNiMo steel

GR
H

Mode of supply: sealed and screwed tightly into the pump end.
GP

Adapter, threaded end G / Flange DN, PN 10/40


with 2 recesses on flange, 90o spacing
(H = 120 mm, D = 155 mm)
-- G 11/2 / DN 40, CrNi steel
-- G 2 / DN 50, CrNi steel
(H = 145 mm, D = 165 mm)
-- G 2 / DN 50, CrNiMo steel
(H = 145 mm, D = 165 mm)
-- G 3 / DN 80, cast iron
(H = 150 mm, D = 200 mm)
-- G 3 / DN 80, CrNiMo steel
(H = 180 mm, D = 200 mm)

D
DN
H

GP

Mode of supply: sealed and screwed tightly into the pump end.
Other sizes and materials on request.

3409:3

Note: 2 pairs are required for installation / dismantling.


Other sizes and materials on request.
Set of bearing pedestals for horizontal installation
consisting of 2 bearing pedestals, incl. screws, bolts and nuts.
Material:
CrNi steel 1.4301
-- UPA 150C pumps with UMA 150D motors . . . . .
Galvanized steel
-- UPA 200 pumps with UMA 150D motors . . . . . . .
S235 JRG2+Z
-- UPA 200 pumps with UMA 200D motors . . . . . . .
CrNi steel 1.4301
-- UPA 200B pumps with UMA 150D motors . . . . .
-- UPA 200B pumps with UMA 200D motors . . . . .
-- UPA 250C pumps with UMA 150D motors . . . . .
-- UPA 250C pumps with UMA 200D motors . . . . .
-- UPA 250C pumps with UMA 250D motors . . . . .
Galvanized steel
-- UPA 300--65 pumps with UMA 200D motors . . .
S235 JRG2+Z
-- UPA 300--94 pumps with UMA 200D motors . . .
-- UPA 350 pumps with UMA 200D motors . . . . . . .
-- UPA 300--65 pumps with UMA 250D motors . . .
-- UPA 300--94 pumps with UMA 250D motors . . .
-- UPA 350 pumps with UMA 250D motors . . . . . . .
Note: Screws, bolts and nuts for fixing the bearing pedestals on the
foundation are to be supplied by the customer / end user.
Other sizes and materials on request.
Pt 100 temperature monitoring equipment for use in submersible motors
to protect the windings from overheating.
Consisting of
-- Resistance thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- Control current line, blue, round 4 x 0.5 mm2 . . . . . . . . . . . . . . . . . . . per m
-- Display / control box (supply voltage U = 110/220V/240V) . . . . . . . . . . . . . .
Note: Motors with Pt 100 are manufactured to order!
Centralizer for submersible motors for UMA 150D and UMA 200D motors
in wells up to DN 350, plastic (PE)
bis DN 250
bis DN 300
bis DN 350
Other sizes and materials on request.

104

----------01 049 403 0.085


00 137 543 0.320

90 047 662
90 047 663
90 047 664

----------------

60 Hz

Accessories

Accessories
Description
Cooling, suction and pressure shroud for vertical and horizontal
installation
Galvanized steel and CrNiMo steel material variants on request.

Stainless steel immersion electrodes


Stainless steel wire rope for S 100D

3 electrodes
1 electrode
15 m
30 m

Lightning protection with earthing terminal for


-- 3~/ 400 V (supplied separately) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . per unit

Ident. No.

kg

------

------

40 980 055 0.3


40 980 056 0.1
42 200 727 0.7
42 204 021 1.2
00 533 299 0.28
40 980 709

105

60 Hz

Accessories

Electric Cable for Use in Drinking Water Applications


Applications
For use in water as standard short submersible motor cable (3- + 4-core, flat) and for use in air as extension cable from motor cable
to control box / mains (3-core, flat and 4-core, round).

Application Limits
Rated voltage:
-- UN 1000 V for ex. in wells,
-- UN 750 V in swimming pools.
Ambient temperature . . . . . t +50 oC.
Immersion depth . . . . . . . . . 500 m.

Description / Design
a) Flat cables:

b) Round cables:
1)

3 cores

2)

4 cores

1) As a standard, for use as short motor


2) For use as earth conductor only.

1 core

4 cores

cable only.

3-/4-core rubber-sheathed cable. Consisting of finely stranded bare copper conductors, core insulation and outer sheath made
of special rubber compound on EPR basis (ethylene propylene rubber), blue. With BAM 1) certificate, i.e. suitable for permanent
use in drinking water applications.
1)

German Federal Institute for Materials Research

Designation (Example)
Flat cable:
ZN 1391 - G
Factory standard
Insulation: rubber
FL: flat + RD: round
For drinking water
Earth conductor: O = without, - J = with
Cores (O: 3 x 25, J: 4 G 25)
Materials

FL

GWT -J 4G25 - Cu-Rubber

Dimensions + Weights
Cross-section
Type

in mm2

1.5

2.5

10

16

25

35

50

70

mm

5.2 + 1

6.1 + 1.5

7.0 + 2

7.6 + 2.2

9.3 + 2.2

11.2 + 2.3

13.0 + 2.5

14.6 + 2.9

17.0 + 3

19.3 + 2.7

$ mm

11.0 + 2

13.2 + 2.3

15.5 + 3.5

17.4 + 3.6

21.5 + 3.5

26.7 + 4.3

31.6 + 3.9

35.5 + 5

42.1 + 4.9

48.4 + 3.6

106

m kg/m

0.110

0.171

0.252

0.319

0.486

0.750

1.107

1.438

2.054

2.760

mm

5.2 + 1

6.1 + 1.5

------

7.6 + 2.2

9.3 + 2.2

11.2 + 2.3

13.0 + 2.5

------

------

------

$ mm

14.5 + 2.7

17.5 + 2.5

------

23.5 + 3

29.0 + 3.5

35.0 + 2.4

41.5 + 4.5

------

------

------

m kg/m

0.165

0.237

------

0.440

0.704

1.026

1.457

------

------

------

mm

5.3 + 1.1

------

------

------

------

------

------

13.8 + 3.6

16 + 3.8

------

m kg/m

0.051

------

------

------

------

------

------

0.499

0.699

------

mm

10.0 + 2

12.0 + 1.9

13.9 + 2

15.7 + 2.1

21.1 + 2.1

24.5 + 4.3

29.7 + 4.3

33.3 + 5.5

39.0 + 5.6

44.2 + 5.8

m kg/m

0.180

0.259

0.356

0.475

0.837

1.220

1.770

2.304

3.185

4.364

60 Hz

Accessories

Maximum Permissible Rated Motor Current Imax


a) Ambient temperature t + 30 oC!
Imax in A
for cross-section of ... mm2
Starting

Used as ...

1.5

2.5

10

16

25

35

50

70

D.o.l.
(1 cable
or
2 cables in parallel 1))

Short motor cable 2)

29

38

52

67

94

125

166

205

256

316

Extension cable 3)

23

30

41

53

74

99

131

162

202

250

Y-
(2 cables)

Short motor cable 2)

50

66

90

116

163

217

288

355

443

547

Extension cable 3)

40

52

71

92

128

171

227

280

350

433

1) For 2 cables II: I 2 x I


N
max.
2) I
max for submerged use, laid in free water or
3) I
max for use in open air, laid along a surface.

closely along the pump. For other conditions see DIN VDE 0298.
For other conditions see DIN VDE 0298.

b) Ambient temperature t > + 30 oC!


If t > + 30 oC, the current-carrying capacity of the cables is lower. Imax indicated under a) must be de-rated by a factor fT:
t in C

fT

[----]

35

40

45

50

0.96

0.91

0.87

0.82

Voltage Drop U Along Extension Cable


When calculating the required copper conductor cross-section q, not only IN, but also the voltage drop U along the cable length
L (distance from motor to control box) must be taken into account. Proper functioning of our submersible motors requires that
U 3 % of the supply voltage U!
If U > 3 %, a larger cable must be used.
The voltage drop is calculated using the following equations:

a) D.o.l. starting / autotransformer ...


-- 1 cable:
3 ...

U =

3.1 x L x IN x cos phi


q x U

[%]

1 ...

U =

3.6 x L x IN x cos phi


q x U

[%]

[%]

1 ...

U =

1.8 x L x IN x cos phi


q x U

[%]

-- 2 cables in parallel (II):


3 ...

U =

1.55 x L x IN x cos phi


q x U

b) Y- starting (2 cables) ...


U =

2.1 x L x IN x cos phi


q x U

[%]

Power Loss P Along the Extension Cable


P =
where ...
L
IN
cos phi
q
U

U
(cos phi) 2

[%]

= single cable length [m]


= rated current [A]
= power factor at 4/4 load
= copper conductor cross-section [mm2]
= supply voltage [V]

107

60 Hz

Accessories

Permissible Cable Lengths L


D.o.l. Starting
(1 cable or 2 cables in parallel)

400
300

70 mm2

Imax = 250 A

50 mm2

Imax = 202 A

200

35 mm2

Imax = 162 A

25 mm2

Imax = 131 A

16 mm2

Imax = 99 A

100
90
80
70

Imax = 74 A

10 mm2

60

6 mm2

Imax = 53 A

50
4.0 mm2

Imax = 41 A

40

2.5 mm2

Imax = 30 A

30

U = 460 V
U = 3 %
t + 30 oC
in air laid along a surface!

1.5 mm2

Imax = 23 A

20

IN
[A]
10
9
8
7
6
5
4
3

1
10

20

30

40

50

60 70 80 90100

L [m]

200

300

400

500

Example:
a) IN = 68 A, 1 x 16 mm2 , U 3 %

L 120 m!

b) IN = 68 A, 1 x 25 mm2 , U 3 %

L 185 m!

For supply voltages other than 460 V, the cable lengths must be calculated as follows, for ex. ...
U1 = 460 V, L1 = 120 m, U2 = 380 V L2 = (U2 : U1) x L1, L2 = (380 V : 460 V) x 120 m = 99 m!
For parallel cables the value is doubled to obtain the permissible length.

108

60 Hz

Accessories

Permissible Cable Lengths L


Y- Starting
(2 cables)

400
300

Imax = 350 A

50

Imax = 280 A

35 mm2

Imax = 227 A

200

16 mm2

Imax = 128 A

10 mm2

6 mm2

Imax = 92 A

4,0 mm2

Imax = 71 A

60

Imax = 52 A

50

2,5 mm2
1,5 mm2

Imax = 40 A

40
30

mm2

25 mm2

Imax = 171 A

100
90
80
70

U = 460 V
U = 3 %
t + 30 oC
in air laid along a surface!

70 mm2

Imax = 433 A

20

IN

[A]
10
9
8
7
6
5
4
3

1
10

20

30

40

50

60 70 80 90100

L [m]

200

300

400

500

Example:
a) IN = 27 A, 2 x 6 mm2, U 3 %

L 165 m!

b) IN = 27 A, 2 x 10 mm2 , U 3 %

L 260 m!

For supply voltages other than 400 V, the cable lengths must be calculated as follows, for ex. ...
U1 = 460 V, L1 = 165 m, U2 = 380 V,
L2 = (U2 : U1) x L1, L2 = (380 V : 460 V) x 165 m = 136 m!
109

60 Hz

Accessories

Connector for Electric Cable


Applications

Used to provide a sealed, water--tight connection between electric extension cable and short submersible motor cable.
Supply voltage . . . . . . . . . . . U 750 V.
Ambient temperature . . . . . t +50 oC.
Immersion depth . . . . . . . . . 500 m.

Selection Criteria

Type, number and dimensions of the standard short motor cable and the extension cable.

Selection Table

The table below only shows the electric cables on stock. Connectors for other cables on request.
Extension cable ... mm2

Standard short
motor cable
mm2

1.5

1.5 / 2.5

28

28

28

35

35

4
6

-------

35
----

35
35

35
35

35
35

10

----

----

----

43

16
25

-------

-------

-------

-------

35
50

-------

-------

-------

70

----

----

----

2.5

10

16

25

35

50

70

43

53

53

----

----

43
43/29 f

53
53/29 f

53
53/39 f

-------

-------

43/29 f

43/29 f

53/29 f

53/39 f

----

----

-------

53
----

53
66

53
66

66
66

66
66

-------

-------

-------

-------

66
66

66
66

66
66

----

----

----

----

----

----

66

Cable connector size ...

1)

1.5 / 2.5
4

28
----

28
35

28
35

35
35

35
35

43
43

53
53

53
53

-------

-------

6
10

-------

-------

35
----

35
43

35
43

43
43

53
53

53
53

-------

-------

16

----

----

----

----

----

53

53

53

66

66

25

----

----

----

----

----

----

66

66

66

66

or

1)

1.5

28

28

28

35

35

----

----

----

----

----

2.5
4

35
----

35
----

35
35

35
35

35
35

---43

-------

-------

-------

-------

----

----

----

43

43

43

53

53

66

66

10
16

-------

-------

-------

66
----

66
----

66
66

66
66

66
66

66
66

66
66

25

----

----

----

----

----

----

78

78

78

----

1)

1.5 / 2.5 / 4

28

28

28

28

35

43

----

----

----

----

28

28

28

28

35

43

53

53

----

----

10
16

-------

-------

35
----

35
----

35
43

43
43

53
53

53
53

---66

---66

25
35

-------

-------

-------

-------

-------

53
----

53
----

53
53

66
66

78
78

50

----

----

----

----

----

----

----

----

66

78

70

----

----

----

----

----

----

----

----

----

78

2)

1)

2)

35

----

----

----

----

----

----

----

35

----

----

50
70

-------

-------

-------

-------

-------

-------

-------

-------

35
----

---35

On stock up to 50 mm2 only.

Legend:
110

2)

For use as earth conductor only.

= G FL GWT -O 3 x ...
= G FL GWT -J 4G ...

= G RD GWT -O 1 G (earth conductor for UMA 300C)


= G RD GWT -J 4G

60 Hz

Accessories

Cable Tie for Electric Cable


Applications
Securing electric cable at the riser / discharge pipe. Suitable for use in normal or slightly aggressive water.
Models for use in more aggressive wasser (for ex. seawater) available on request.

Selection Criteria
Type, number and size of the electric cable, as well as nominal diameter and length of the riser / discharge pipe.

Selection Table
Electric cable

Number x core
dia. in mm2

Type

Flat

Round

1)

Tie
size

m 1)

Required length of strap L per cable tie in ... mm


for risers G .../DN ...

----

kg

11/4 /
32

11/2 /
40

2/
50

21/2/
65

3/
80

4/
100

5/
125

6/
150

7/
175

8/
200

10
250

12
300

14
350

16
400

3 x 1.5
to
3 x 6.0

4 x 1.5
to
4 x 6.0

----

270

280

320

360

400

450

500

600

--------

--------

--------

--------

--------

--------

3 x 10
to
3 x 70

4 x 10
to
4 x 70

11

0.01

----

----

350

400

450

550

650

800

950

1100

1300

1500

1700

1900

3 x 1.5
to
3 x 6.0

4 x 1.5
to
4 x 6.0

----

270

280

320

360

400

450

500

600

------

------

------

------

------

------

3 x 10

4 x 10

0.08

----

----

350

400

450

550

650

800

950

1100

1300

1500

1700

1900

3 x 16
3 x 25

4 x 16

3a

0.19

------

------

350

400

450

550

650

800

950

1100

1300

1500

1700

1900

3 x 35
3 x 50

4 x 25
4 x 35

0.19

------

------

------

450

500

600

700

850

1000

1150

1350

1550

1750

1950

3 x 70

4 x 50

3b

0.19

------

------

------

450

500

600

700

850

1000

1150

1350

1550

1750

1950

3 x 95

4 x 70
4 x 95

0.55

------

------

------

------

------

650

750

900

1050

1200

1400

1600

1800

2000

3 cables 1 x 50

0.6

------

------

------

------

------

700

800

950

1100

1250

1450

1650

1850

2050

3 cables 1 x 70

0.6

------

------

------

------

------

700

800

950

1100

1250

1450

1650

1850

2050

3 cables 1 x 95

0.6

------

------

------

------

------

700

800

950

1100

1250

1450

1650

1850

2050

3 cables 1 x 120
3 cables 1 x 150

0.6

------

------

------

------

------

700

800

950

1100

1250

1450

1650

1850

2050

Cable protector (Sizes 11, 2 to 9).

Design
Size 11:

Size 1:

b
a
d

Sizes 2, 3, 3a, 3b, 4:

Sizes 6, 7, 8, 9:

d
b
c
e

c
a

a=
b=
c=
d=

Riser
Electric cable
Rubber strap
Plastic stud (2 pcs/cable tie)

a = Riser
b = Electric cable
c = Metal strap

d = Cable protector
e = Screw band with tension screw
(re-usable)

Note:
-- Use 1 cable tie each per cable and per 3 m of riser pipe.
-- If an extension cable with a larger diameter is connected to the standard short motor cable, the cable tie size required for the
larger cable is to be used along the entire cable length.

111

Submersible borehole pumps

60 Hz
Flow Velocity v Past the UMA Submersible Motor

Depending on the general installation arrangement (i.e. depending, for example, on the ratio of outside motor diameter to inside
well or shroud diameter, etc.) a distinction must be made between the following cases ...
a) v = 0 m/s ... this applies, for example, when the pump set is installed in a deep well below the well screen / filter,
in a pump sump, tank or other reservoir, etc.
Caution: At v = 0 m/s, UMA 250D motors can only be operated at reduced rated power.
b) v 0.2 m/s ... this describes with adequate accuracy the case when the pump set is, for example, installed in a deep well above
the well screen / filter, etc. In borderline cases (for ex. if the inside well diameter is very large compared with the
outside motor diameter) the diagram below can be used to double-check the data.
c) v 0.5 m/s ... In this case it must always be checked, using the diagram below, whether the installation dimensions
(i.e. the ratio of outside motor diameter to inside well diameter) are adequate to ensure a minimum flow velocity
past the motor of v 0.5 m/s. If not, use a special cooling shroud.
How to read the diagram:
The requirement for a flow velocity past the motor of v 0.2 or 0.5 m/s is met, if the point of intersection of the capacity Q and
the inside well or shroud diameter DN is located on or to the right of the curve applicable to the submersible motor used.

Max. permissible well diameter for compliance with


required flow velocity past the motor
1400
V >= 0.2 m/s

1200
[mm]
1000
V >= 0.5 m/s

800
DN 100V 0.1

600

UMA 300D
UMA 250D
UMA 200D
UMA 150D
DN 100

400
200
0
0

100

200

300

400

500

600

700

800

900

Q [m#/h]

Example:
Given:
UPA 300 - 65/4 + UMA 250D 160/21 and v 0.5 m/s.
Found:
For Q = 250 m3/h ( Qopt) the following applies: DN 700 mm.
This means that the requirement for v 0.5 m/s is met, if the pump set is, for example, installed in a well or cooling shroud of
DN 700 mm or 28 inches.

112

60 Hz

Submersible borehole pumps

113

3400.51/2--10

06/2008

Subject to technical modification without prior noice.