The automatic battery charger allows to charge and maintain a set of battery, ensuring the
efficiency and life of the batteries of a genset.
Innovation and quality are the base philosophy which defined the production of a rugged line
of <<battery chargers>>, able to meet the most different needs.
These automatic battery chargers include a series of features able to fit the most common
types of batteries (with lead and with nickel/cadmium) keeping unchanged and constant the
various requirements for recharge cycle and for maintaining the battery as a buffer unit.

Operation features
The automatic battery charger is composed by a compact single block
suitable to be fixed on wall and completed with transformer and electronic
control part, with dissipator components for charge modulation and visual
display of running state lamp (led).
Start of battery charge with gradual change of charge current value from
<<O>> to the maximum value. Thus its possible to have a charge with
defined and regular current and variable voltage.
Once the value of rated voltage is reached, there is a gradual current
variation and a battery charge with constant voltage at the value.
In case of high absorption or at the start of the charge, it is possible to set
a time of 2 to 60 minutes for automatic full charge, using a potentiometer
on the front of the battery charger.
Furthermore there is the possibility to select the full charge with external
signal.
The modulation of power to charge the battery is done using some diodes
which shut the transformer secondary winding.
On the front of the battery charger a series of leds is fit, signalling the status.

Options

REMOTE SIGNALING: allows a remote repetition of the battery conditions.


BATTERY FAILURE: detection of an abnormal lasting state of battery voltage.
CURRENT/VOLTAGE COMMUTATION: according to charge current, the voltage value at end of charge is automatically
preset.
DISPLAY OF STATE CONDITIONS: to check rapidly the battery efficiency. Battery state: High, Medium, Low.
PROTECTION FUSE: to protect the battery charger on supply from network.
REGULATION OF CURRENT OUTPUT: a current output at a preset value is obtained by means of a selector with 2 to 6 fixed
values or with potentiometer.
COMMUTATION FOR SELECTION OF INITIAL CHARGE: allows the selection of an initial charge rating to start the battery.
STABILISED OUTPUT: by reducing the ripple rate to minimum, it is possible to use the battery charger as Feeder.
THERMAL PROTECTION: protection of the battery charger by means of a special temperature sensor.
ANTI-STATIC FILTER: for use of the battery charger in a particular environment.

Technical features e t
Voltage supply
Battery voltage:
Regulation accuracy limits
Current output
Rated current
Working temperature:
Charge rates:
Automatic charge
Full charge

230V - 400V AC 15% 50-60Hz - supplied with proper protection fuses


Special multivoltage 0-230-240-260-280-400-415-440V
12 24VDC
1%
From 0 to rated I
5A - 10A - 15A - 20A
- 20 / +60 C Installation in an properly ventilated environment
Lead battery / Nickel/Cadmium battery
2,18V 1,4V
2,25V 1,45V

If required, available tropicalized version for hazardous areas.

AUTOMATIC BATTERY CHARGER 5A-10A-15A-20A_ENG_00_14

Models and dimensions


DIMENSIONS (mm)
Types

VOLTAGE

kg

CURRENT
(a)

(b)

(c)

(d)

(h)

WEIGHT

CB 001

12V

5A

270

150

112

248

130

4,90

CB 002

24V

5A

270

150

112

248

150

7,00

CB 003

12V

10A

270

150

112

248

130

7,00

CB 004

24V

10A

270

150

112

248

150

10,80

CB 006

24V

15A

315

200

155

288

160

13.90

CB 008

24V

20A

460

210

155

431

210

29.40

S.I.C.E.S. SRL
Societ Italiana Costruzioni Elettriche Sumirago
Via Molinello 8B
21040 - Jerago con Orago (VA) ITALY
T +39 0331 212941
F +39 0331 216102
www.sices.eu
sales@sices.eu

SICES BRASIL LTDA


Avenida Juru 105 Barueri Bloco 5
06455 010 So Paulo (BR)
CNPJ 17.774.501/0001-28
+55 (11) 4193 2008
www.sicesbrasil.com.br
contato@sicesbrasil.com.br

You might also like