Item N

Location
1.1

ID Component

Exterior
Component Name
Parapets

1.1.1

GENERAL VIEW

Description

VIEW 2
VIEW 3
Location: On the first, second and third floor. Dimensions: 0.9 x 0.25 m.

Danger - Observation

Typically the parapets fail out of its plane and fall to the seismic action.

Table 1. Format Visual Inspection. Parapets

Example N

6.3.5.1

Name Example
Unreinforced masonry parapets
Additionally

VIEW 3
third floor. Dimensions: 0.9 x 0.25 m.

s plane and fall to the seismic action.

tion. Parapets

PHOTO

MAIN
0

PHOTO 1

Item N

ID component

1.1

1.1.1

1.1

1.1.2

1.6

1.2.2

1.6

1.1.2

1.6

1.1.2

1.6

1.2.1

Component name

Example N

Name Example

Parapets

6.3.5.1

Unreinforced masonry
parapets

Glazed Exterior

6.3.1.4

Glazed exterior wall


system

Ceiling - Gypsum

6.3.4.1

Suspended acoustic lay-in


tile ceiling

Aluminum and Glass - Glazed

6.3.2.3

Glazed

Glazed Inteior Partition

6.3.2.3

Glazed

Masonry Wall Interior Partitions

6.3.2.1

Heavy

Table N

Description

Table 1. Format Visual


Inspection. Parapets

Location: On the first, second


and third floor. Dimensions: 0.9 x
0.25 m.

Table 2. Format Visual


Inspection. Glazed
exterior wall system

Common glass, the dimensions


vary according to the
architectural distribution.

Table 3. Format Visual


Location: On the ground floor,
Inspection. Suspended
first, second and third floor.
acoustic lay-in tile ceiling Dimensions: Various.

Table 4. Format Visual


Inspection. Glazed

Glaced in areas such as nursing


station, halls and others.

Table 5. Format Visual


Glaced in areas such as entrance
Inspection. Glazed Interior doors, halls, room care and
Partition
others.

Table 6. Format Visual


Inspection. Masonry Wall
Interior

There are divisions masonry


around the hospital under
architectural considerations.

Danger-Observation

Typically the parapets fail out of its plane


and fall to the seismic action.
These elements are subject to failures
outside the plane. Glass is particularly
vulnerable in flexible structures with high
drift values may fall large and small pieces
of glass

The flaw in the ceiling may be that the


Screens may be affected due to loads in its
hospital should be evacuated and lose
plane or out of plane to avoid these
functionality until it is repaired.
damages must present adequate details of
assembly. Cause risk if they fail corridors or
areas that need to be evacuated. They are
vulnerable when there is insufficient spacing
Screens may be affected due to loads in its
and insulation to accommodate the
plane or out of plane to avoid these
displacements that occur.
damages must present adequate details of
assembly. Cause risk if they fail corridors or
areas that need to be evacuated. They are
vulnerable when there is insufficient spacing
and insulation to accommodate the
displacements that occur.
The masonry affects both accelerations as
displacement, mainly out of the plane
crashing when not have proper construction
details.

1
1.1
1.2
1.3
1.4
1.5
1.6
1.1.1
1.1.2
1.2.1
1.2.2

TABLE BASE
Architectural Components
Exterior
First Floor
Second Floor
Third Floor
Fourth Floor
All Floors
Parapets
Window Frames (Glass)
Masonry wall
Suspended acoustic lay-in tile ceiling