METHOD STATEMENT FOR REPAIR OF HONY COMB

0 26/11/2015
REV No.
Date

Prepared by

Reveiwed by

Approved by

BL KASHYAP & SONS LTD


EMBASSY ONE PROJECT

Revision No.

:0

Date

: 26/11/2015

Page

: 02

METHOD STATEMENT FOR REPAIR OF HONYCOMB


SCOPE:Scope of the worke includes control &rectification of honey combs in concrete surface.
GROUTING:This work shall consist of furnishing and grouting of honey comb portion with CONBEXTRA GP2 or
equivalent chemical with water ratio as per manufacture specifications.
MATERIALS:1.Water: The water to be used shall be free from oils, acids, alkalis, salts, sugar, organic materials or other
substances that may be deleterious to concrete and steel. Potable water generally considered satisfactory.
The water to be used shall satisfy the requirements as per IS 456-2000.
2.Grouting material: CONBEXTRA GP2
Sl. No.

Procedure

Responsibility

Check By

Records

The surface where treatment to be received shall


be cleaned properly with suitable brush / tool and
remove the oil materials and surface shall be
roughned. The surface shall be pre-wetted with
suitable tools.

Site Engineer

Site In-Charge /
QA/QC
Engineer

The surface then shal be coated with Nito bond


or equivalent. Care should be taken to ensure
that the surface is dry while applying Nito Bond
or equivalent.

Site Engineer

Site In-Charge /
QA/QC
Engineer

The consistance paste of CONBEXTRA GP2 or


equivalent to be prepared and the effcted area to
be packed properly.

Site Engineer

Site In-Charge /
QA/QC
Engineer

Site Engineer

Site In-Charge /
QA/QC
Engineer

The surface where treatment to be received shall


be cleaned properly with suitable brush / tool and
remove the oil materials and surface shall be
roughned. The surface shall be pre-wetted with
suitable tools.

Site Engineer

Site In-Charge /
QA/QC
Engineer

The surface then shal be coated with Nito bond


or equivalent. Care should be taken to ensure
that the surface is dry while applying Nito Bond
or equivalent.

Site Engineer

Site In-Charge /
QA/QC
Engineer

The consistance paste of CONBEXTRA GP2 or


equivalent to be prepared and the effcted area to
be packed properly.

Site Engineer

Site In-Charge /
QA/QC
Engineer

If the surface needs to be repaired is more than


50mm/ 100mm deep, then 12.5mm down or
below size of aggregate need to be added as per
specification

Site Engineer

Site In-Charge /
QA/QC
Engineer

Site Engineer

Site In-Charge /
QA/QC
Engineer

For surface honeycomb


1

The repaired area to be cured continiuosly for


7days.
For major honeycomb

The repaired area to be cured continiuosly for


7days.

26/11/2015

Rev No.

Date

Prepared by

Reveiwed by

Approved by

BL KASHYAP & SONS LTD


EMBASSY ONE PROJET

Revision No. : 0
Date

: 26/11/2015

Page

:03

CHECK FOR REPAIR OF HONY COMBS ON CONCRETE SURFACE


Project

Area / Building

Date :

Description of Work / Drg Ref. :

Sl.No.

Descriptiopn

Surface treatment.

Nito bond/cement slurry application.

Filling of CONBEXTRA GP2

Curing works.

Date

Required

Signature
BLK

YES / NO
YES / NO
YES / NO
YES / NO

Remarks: Approved / Not Approved.

BLK SITE ENGG.

CLIENT / PMC

Client

BL KASHYAP & SONS LTD


EMBASSY ONE PROJET

Revision No.

:0

Date

1/12/2015

Page

: 01

METHOD STATEMENT FOR REPAIR OF BULGED SURFACE

REV No.

1/12/2015
Date

Prepared by

Reveiwed by

Approved by

BL KASHYAP & SONS LTD


EMBASSY ONE PROJECT

Revision No.
Date
Page

METHOD STATEMENT FOR REPAIR OF BULGED SURFACE


SCOPE:Scope of the worke includes control & rectification of bulged surface.
GROUTING:This work shall consist of finishing with CONBEXTRA GP2 or equivalent chemical with water ratio as per
manufacture specifications.

MATERIALS:1.Water: The water to be used shall be free from oils, acids, alkalis, salts, sugar, organic materials or other

Sl. No.

2.Grouting material: CONBEXTRA GP2


Procedure
The surface ( where treatment to be
received )shall be measured for the
amount of bulge and then start chipping
using suitable tools. During chipping the
reinforcement should not get exposed to
the atmosphare .
After chipping the surface shall be cleaned
properly with suitable brush / tool to
remove the debries. Then the surface
shall be pre-wetted with suitable tools.

The surface then shall be coated with Nito


bond or equivalent. Care should be taken
to ensure that the surface is dry while
applying Nito Bond or equivalent.
The consistant paste of CONBEXTRA
GP2 or equivalent should be prepared and
the effcted area should be packed
properly.
The repaired area to be cured continiuosly
for 7days.

: 01/12/2015

Rev No.

Date

Prepared by

Responsibility

Check By

Site Engineer

Site InCharge /
QA/QC
Engineer

Site Engineer

Site InCharge /
QA/QC
Engineer

Site Engineer

Site InCharge /
QA/QC
Engineer

Site Engineer

Site InCharge /
QA/QC
Enineer

Site Engineer

Site InCharge /
QA/QC
Engineer

Reveiwed by

Approved by

:0
: 01/12/2015
: 02

ent chemical with water ratio as per

alts, sugar, organic materials or other

Records

Approved by

BL KASHYAP & SONS LTD


EMBASSY ONE PROJET

Revision N : 0
Date
: 01/12/2015
Page

:03

CHECK FOR REPAIR OF BULGED CONCRETE SURFACE


Project
:
Area / Building
:
Description of Work / :
Sl.No.

Descriptiopn

Date :

Date

Required

Surface treatment.

Nito bond/cement
slurry application.

YES / NO

Applying of
CONBEXTRA GP2

YES / NO

Curing works.

Signature
BLK
Client

YES / NO

YES / NO

Remarks: Approved / Not Approved.

BLK SITE ENGG.

CLIENT / PMC

BL KASHYAP & SONS LTD


EMBASSY ONE PROJET

Revision N
Date
Page

METHOD STATEMENT FOR PAINTING OF STRUCTURAL STEEL WORK

26/11/201
0 5
REV No.

Date

Prepared by

Reveiwed by

Approved by

:0
26/11/2015
: 01

URAL STEEL WORK

Approved by