You are on page 1of 2

TF10019

A-DF(ZN)2Y(SR)2Y
Double PE Sheathed, Corrugated Steel Tape Armoured, Direct
Buried type optical cable
Cable Design

IEC/EN 60794-3-10

Central strength member (CSM): glass fibre reinforced plastic material


(GRP).
Tube: thermoplastic material, containing 6 single-mode optical fibres and
filled with a suitable water tightness compound.
Stranding: the required numbers of elements (tubes or fillers) are SZ
stranded around the central strength member.
Longitudinal Water Tightness: filled core.
Peripheral reinforcement: aramid yarns.
Inner Sheath: MDPE ,Min thickness : 1.5 mm, 2 ripcords beneath the sheath
Armour: both sides copolymer coated corrugated steel tape with overlap,
nom. steel thickness: 0.15 mm. Water swellable tape will be applied under
the armour. 2 ripcords beneath the tape.
Outer Sheath: HDPE

With its HDPE sheathing this cable is ideal for outdoor installation.

Technical data
No. of Fibres
Design
Loose Tube / Filler -
CSM
Sheath thickness
Cable Diameter
Cable Weight
Max installation tension

24
4x6E+2F
Min 2.3
2.5
2.0 (0.1)
16.7
253
4000 N

mm
mm
mm
mm
kg / km
N

Min. bending radius

mm

Temperature range

Without Tension
15 x Cable-
Installation
-30 -> +60;

Under Maximum Tension


20 x Cable-
Transport. & Storage
Operation
-40 -> +80 ;
-40 -> +80

Main characteristics
Test
Maximum Tension at
installation (short term)
Crush
Impact

Standard
IEC 60794-1-2-E1

Value
4000 N

Sanction*
0.05 dB

IEC 60794-1-2-E3
IEC 60794-1-2-E4

0.05 dB
0.05 dB

Cable cold bend

IEC 60794-1-2-E11

4400 N / 100mm, max 5 min


5 Nm, 25 impacts (distance:300
mm), r=300mm
R = 20 x cable / -30C + 60C

Torsion
IEC 60794-1-2-E7
100 N, +- 180, 10 cycles
Repeated bending
IEC 60794-1-2-E6
R= 20 x cable , 100N, 10 cycles
Cable bend
IEC 60794-1-2-E11
R = 20 x cable
Temperature range
IEC 60794-1-2-F1
-40 -> +80C
Water Penetration
IEC 60794-1-2-F5B
sample=3m, water=1m
Compound flow test
IEC 60794-1-2-E14
24 hours @ 70 C
Kink test
IEC 60794-1-2-E10
Loop=Min 20 x cable
Cable Aging
IEC 60794-1-2-F1
168 hours@80C
* values for single-mode fibres, all optical measurements performed at 1550 nm

0.1 dB , no damage or
breakage of cable
0.05 dB
0.05 dB
0.05 dB (after the test)
0.05 dB /km
No water leakage after 24 hour
No flow
No damage
0.05 dB /km

Optical Characteristics
See the attached cabled optical fibre data sheet.

Loose tube

www.prysmiangroup.com

TF10019-A-DF(ZN)2Y(SR)2Y-06464
Issued 2014-11-27 BS / Page 1 of 2

TF10019
A-DF(ZN)2Y(SR)2Y
Identification
Fiber Colors
No.
Color

white

red

green

blue

yellow

black

red

green

blue

yellow

Buffer Tube Colours


No.
Color

Fillers are naturel coloured


Sheath Colour:
The inner/outer sheath colour is black.
Sheath Marking:
The outer sheath is marked in 1 meter intervals as follows:

PRYSMIAN mm yyyy A-DF(ZN)2Y(SR)2Y

OPTICAL CABLE

24 SM G652D NIGC

zzzz

mm yyyy (mount / year) zzzz (Sequential Length Mark)

Logistic
Packing:
Wooden drums with protection.
Delivery Lengths:
Standard delivery length is 4.1 km with a tolerance of 5%

PRYSMIAN 2014, All Rights Reserved


All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian: any modification or
alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the
written consent of Prysmian. The information is believed to be correct at the time of issue. Prysmian reserves the right to amend this
specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Loose tube

www.prysmiangroup.com

TF10019-A-DF(ZN)2Y(SR)2Y-06464
Issued 2014-11-27 BS / Page 2 of 2

You might also like