Professional Documents
Culture Documents
INFTERFACE UNIT
USER MANUAL
4) Select MODE type you want and push SET button so that you can use the
MODE type or you can change setting by pushing SET button.
5) If you push MODE button one more, LCD screen will be off
1. Simulate Alarm
- Regardless of outside alarm signal, it virtually transmit alarm signal to each
SIGNAL LIGHT COLUMN. In this case, each SIGNAL LIGHT COLUMN is
operating as if real alarm happened.
1) Push MODE button.
* Mode Select
1. Simulate Alarm
3) If you push direction button, the type of alarm you want to test will be
changing in order
> Simulate Alarm
2. FIRE EM'CY
> Simulate Alarm
3. CO2 RELEASE
> Simulate Alarm
4. WATER FOG
> Simulate Alarm
5. MACHINERY
> Simulate Alarm
6. DEAD MAN
> Simulate Alarm
7. TELEGRAPH
> Simulate Alarm
8. TELEPHONE CALL
4) Select Alarm button you want to test and push SET button one more.
If you selected GENERAL EM'CY, GENERAL EM'CY signal will be transmitted
to each COLUMN and each COLUMN sounds warning alarm.
6) If you push MODE button one more, it will return to MODE SELECTOR
screen and if you push the button one more LCD screen will be off
2. Set Priority
You can set priority for preference alarm
1) Push MODE button.
* Mode Select
1. Simulate Alarm
4) If you push direction button, the type of alarm you want to change priority
will be changing in order
> Set Priority
2. FIRE ALARM
> Set Priority
3. CO2 RELEASE
> Set Priority
4. WATER FOG
> Set Priority
5. MACHINERY
> Set Priority
6. DEAD MAN
> Set Priority
7. TELEGRAPH
> Set Priority
8. TELEPHONE CALL
5) Select the alarm you want to change and push SET button one more.
If you selected GENERAL EM'CY, GENERAL EM'CY will be your priority and
it will show on the screen
>>GENERAL EM'CY
<-
->
->
8) If you push MODE button, it will return to MODE SELECTOR screen and if
you push one more LCD screen will be off
3. Set Alarm Time
- You can set delaying time for each alarm
- ON TIME DELAY : If setting time has passed after setting of alarm, alarm
sounds in COLUMN
- OFF TIME DELAY : When alarm was set and cleared, if setting time has
passed the alarm will be cleared in COLUMN.
1) Push MODE button.
* Mode Select
1. Simulate Alarm
4) If you push direction button, the type of alarm which is going to set delaying
time will be changing in order.
> Set Alarm Time
2. FIRE ALARM
>>GENERAL EM'CY
->ON:00
OFF:00
6) You can set time by pushing direction button and it can be set max.
99seconds.
>>GENERAL EM'CY
->ON:99
OFF:00
7) After setting of ON TIME DELAY, if you push SET button the setting value
will be saved and cursor will move to OFF TIME DELAY mode
>>GENERAL EM'CY
ON:99
->OFF:00
8) After setting of OFF TIME DELAY, if you push SET button the setting value
will be saved and cursor will move to OFF TIME DELAY.
>>GENERAL EM'CY
->ON:99
OFF:05
10) If you push MODE button, it will return to MODE SELECTOR screen and if
you push one more LCD screen will be off
4. Set Sound Kind
- You can select the type of warning sound for each alarm
1) Push MODE button.
* Mode Select
1. Simulate Alarm
4) If you push direction button, the type of alarm you want to change sound will
be changing in order.
5) Select alarm you want to change and push SET button one more.
If you selected GENERAL EM'CY, the setting mode of current GENERAL
EM'CY sound will show up.
>>GENERAL EM'CY
<-
->
6) You can change the type of sound by pushing direction button and it can be
set 57 of different sound.
>>GENERAL EM'CY
<-
->
7) If you push SET button after sound setting, the setting value will be saved
and it will move to sound setting screen.
10) If you push MODE button it will return to MODE SELECTOR screen and if
you push button one more LCD screen will be off
5. Set Default
All setting value will return to initial status(Default)
.
1) Push MODE button.
* Mode Select
1. Simulate Alarm
Mode:No
4) If you push SET button, it will be default and LCD Display will be off.
6) If you push MODE button, it will return to MODE SELECTOR screen and LCD
screen will be off if you push one more.
Frequency Timbre
NO.
Continuous at 300Hz
21
Continuous at 450Hz
22
42
Continuous at 600Hz
23
43
Continuous at 750Hz
24
Continuous at 900Hz
25
45
Continuous at 1000Hz
26
46
Continuous at 1100Hz
27
Continuous at 1200Hz
28
48
Continuous at 1300Hz
29
49
10
Continuous at 1400Hz
30
50
31
51
400Hz~600Hz Calling,
Delay 1Second
Delay 1Second
11
600Hz~1000Hz Sweeping
at 0.5Hz
Frequency Timbre
200Hz Pulsing at
700Hz Pulsing at
1200Hz Pulsing at
0.5Hz
0.5Hz
0.5Hz
NO.
41
44
47
Frequency Timbre
500Hz Sawtooth at
900Hz Sawtooth at
1800Hz Sawtooth at
2900Hz Sawtooth at
0.5Hz
0.5Hz
0.5Hz
0.5Hz
12
32
300Hz~400Hz
Alternating at 1Hz
52
800Hz~1000Hz Calling,
13
33
300Hz~400Hz
Alternating at 2Hz
53
54
14
800Hz~1200Hz Sweeping
at 0.5Hz
34
15
35
600Hz~800Hz
Alternating at 1Hz
55
16
36
600Hz~800Hz
Alternating at 2Hz
56
17
37
900Hz~1100Hz
Alternating at 0.5Hz
57
7 short 1 long
18
1400Hz~1800Hz
Sweeping at 1Hz
38
19
1400Hz~1800Hz
Sweeping at 2Hz
39
20
1800Hz~2400Hz
Sweeping at 2Hz
40