You are on page 1of 12

SIGNAL LIGHT COLUMN

INFTERFACE UNIT
USER MANUAL

< INTERFACE UNIT >

< INTERFACE UNIT DISPLAY >


* MODE SELECT
1) Push MODE button
2) Push dirction button(Left/Right)
3) MODE will be changing in order as below
* Mode Select
1. Simulate Alarm
* Mode Select
2. Set Priority
* Mode Select
3. Set Alarm Time
* Mode Select
4. Set Sound Kind
* Mode Select
5. Set Default

4) Select MODE type you want and push SET button so that you can use the
MODE type or you can change setting by pushing SET button.
5) If you push MODE button one more, LCD screen will be off

1. Simulate Alarm
- Regardless of outside alarm signal, it virtually transmit alarm signal to each
SIGNAL LIGHT COLUMN. In this case, each SIGNAL LIGHT COLUMN is
operating as if real alarm happened.
1) Push MODE button.
* Mode Select
1. Simulate Alarm

2) Push SET button.


> Simulate Alarm
1. GENERAL EM'CY

3) If you push direction button, the type of alarm you want to test will be
changing in order
> Simulate Alarm
2. FIRE EM'CY
> Simulate Alarm
3. CO2 RELEASE
> Simulate Alarm
4. WATER FOG
> Simulate Alarm
5. MACHINERY
> Simulate Alarm
6. DEAD MAN
> Simulate Alarm
7. TELEGRAPH
> Simulate Alarm
8. TELEPHONE CALL

4) Select Alarm button you want to test and push SET button one more.
If you selected GENERAL EM'CY, GENERAL EM'CY signal will be transmitted
to each COLUMN and each COLUMN sounds warning alarm.

>> GENERAL EM'CY


CANCEL : SET Key
5) Push SET button one more then alarm will be off
> Simulate Alarm
1. GENERAL EM'CY

6) If you push MODE button one more, it will return to MODE SELECTOR
screen and if you push the button one more LCD screen will be off
2. Set Priority
You can set priority for preference alarm
1) Push MODE button.
* Mode Select
1. Simulate Alarm

2) Push direction button(Right).


* Mode Select
2. Set Priority

3) Push SET button.


> Set Priority
1. GENERAL EM'CY

4) If you push direction button, the type of alarm you want to change priority
will be changing in order
> Set Priority
2. FIRE ALARM
> Set Priority
3. CO2 RELEASE
> Set Priority
4. WATER FOG
> Set Priority
5. MACHINERY
> Set Priority
6. DEAD MAN
> Set Priority
7. TELEGRAPH
> Set Priority
8. TELEPHONE CALL

5) Select the alarm you want to change and push SET button one more.
If you selected GENERAL EM'CY, GENERAL EM'CY will be your priority and
it will show on the screen

>>GENERAL EM'CY
<-

->

6) Push direction button.


Your priority alarm mode will be changed from 1 to 8
>>GENERAL EM'CY
<-

->

7) Select preference Priority and push SET button


The changed mode will be saved and it will return to setting screen of
preference priority
> Set Priority
1. GENERAL EM'CY

8) If you push MODE button, it will return to MODE SELECTOR screen and if
you push one more LCD screen will be off
3. Set Alarm Time
- You can set delaying time for each alarm
- ON TIME DELAY : If setting time has passed after setting of alarm, alarm
sounds in COLUMN
- OFF TIME DELAY : When alarm was set and cleared, if setting time has
passed the alarm will be cleared in COLUMN.
1) Push MODE button.
* Mode Select
1. Simulate Alarm

2) Push direction button(Right) twice.


* Mode Select
3. Set Alarm Time

3) Push SET button.


> Set Alarm Time
1. GENERAL EM'CY

4) If you push direction button, the type of alarm which is going to set delaying
time will be changing in order.
> Set Alarm Time
2. FIRE ALARM

> Set Alarm Time


3. CO2 RELEASE
> Set Alarm Time
4. WATER FOG
> Set Alarm Time
5. MACHINERY
> Set Alarm Time
6. DEAD MAN
> Set Alarm Time
7. TELEGRAPH
> Set Alarm Time
8. TELEPHONE CALL
5) Select alarm you want to set and push SET button one more.
If you selected GENERAL EM'CY, the current setting states of delaying time
will show up. Initial state is set to 0 second.

>>GENERAL EM'CY
->ON:00

OFF:00

6) You can set time by pushing direction button and it can be set max.
99seconds.
>>GENERAL EM'CY
->ON:99

OFF:00

7) After setting of ON TIME DELAY, if you push SET button the setting value
will be saved and cursor will move to OFF TIME DELAY mode
>>GENERAL EM'CY
ON:99

->OFF:00

8) After setting of OFF TIME DELAY, if you push SET button the setting value
will be saved and cursor will move to OFF TIME DELAY.

>>GENERAL EM'CY
->ON:99

OFF:05

9) Push MODE button.


It will move to delaying time's setting mode
> Set Alarm Time
1. GENERAL EM'CY

10) If you push MODE button, it will return to MODE SELECTOR screen and if
you push one more LCD screen will be off
4. Set Sound Kind
- You can select the type of warning sound for each alarm
1) Push MODE button.
* Mode Select
1. Simulate Alarm

2) Push direction button(Right) three times.


* Mode Select
4. Set Sound Kind

3) Push SET button.


> Set Sound Kind
1. GENERAL EM'CY

4) If you push direction button, the type of alarm you want to change sound will
be changing in order.

> Set Sound Kind


2. FIRE ALARM
> Set Sound Kind
3. CO2 RELEASE
> Set Sound Kind
4. WATER FOG
> Set Sound Kind
5. MACHINERY
> Set Sound Kind
6. DEAD MAN
> Set Sound Kind
7. TELEGRAPH
> Set Sound Kind
8. TELEPHONE CALL

5) Select alarm you want to change and push SET button one more.
If you selected GENERAL EM'CY, the setting mode of current GENERAL
EM'CY sound will show up.
>>GENERAL EM'CY
<-

->

6) You can change the type of sound by pushing direction button and it can be
set 57 of different sound.
>>GENERAL EM'CY
<-

->

7) If you push SET button after sound setting, the setting value will be saved
and it will move to sound setting screen.

> Set Sound Kind


1. GENERAL EM'CY

10) If you push MODE button it will return to MODE SELECTOR screen and if
you push button one more LCD screen will be off
5. Set Default
All setting value will return to initial status(Default)
.
1) Push MODE button.
* Mode Select
1. Simulate Alarm

2) Push direction button(Right) 4times.


* Mode Select
5. Set Default

3) Push SET button.


> Are you sure?
Set:Yes,

Mode:No

4) If you push SET button, it will be default and LCD Display will be off.

5) If you push MODE button, it will be out to Set Default.


* Mode Select
5. Set Default

6) If you push MODE button, it will return to MODE SELECTOR screen and LCD
screen will be off if you push one more.

Signal Light Column Sound Table


NO.

Frequency Timbre

NO.

Continuous at 300Hz

21

Continuous at 450Hz

22

200Hz Pulsing at 1Hz

42

500Hz Sawtooth at 1Hz

Continuous at 600Hz

23

200Hz Pulsing at 2Hz

43

500Hz Sawtooth at 2Hz

Continuous at 750Hz

24

Continuous at 900Hz

25

700Hz Pulsing at 1Hz

45

900Hz Sawtooth at 1Hz

Continuous at 1000Hz

26

700Hz Pulsing at 2Hz

46

900Hz Sawtooth at 2Hz

Continuous at 1100Hz

27

Continuous at 1200Hz

28

1200Hz Pulsing at 1Hz

48

1800Hz Sawtooth at 1Hz

Continuous at 1300Hz

29

1200Hz Pulsing at 2Hz

49

1800Hz Sawtooth at 2Hz

10

Continuous at 1400Hz

30

1700Hz Pulsing at 2Hz

50

31

300Hz~400Hz Alternating at 0.5Hz

51

400Hz~600Hz Calling,

Delay 1Second
Delay 1Second

11

600Hz~1000Hz Sweeping

at 0.5Hz

Frequency Timbre
200Hz Pulsing at

700Hz Pulsing at

1200Hz Pulsing at

0.5Hz

0.5Hz

0.5Hz

NO.
41

44

47

Frequency Timbre
500Hz Sawtooth at

900Hz Sawtooth at

1800Hz Sawtooth at

2900Hz Sawtooth at

0.5Hz

0.5Hz

0.5Hz

0.5Hz

12

600Hz~1000Hz Sweeping at 1Hz

32

300Hz~400Hz

Alternating at 1Hz

52

800Hz~1000Hz Calling,

13

600Hz~1000Hz Sweeping at 2Hz

33

300Hz~400Hz

Alternating at 2Hz

53

1200Hz~1400Hz Calling, Delay 1Second

54

1600Hz~1800Hz Calling, Delay 1Second

14

800Hz~1200Hz Sweeping

at 0.5Hz

34

600Hz~800Hz Alternating at 0.5Hz

15

800Hz~1200Hz Sweeping at 1Hz

35

600Hz~800Hz

Alternating at 1Hz

55

2000Hz~2200Hz Calling, Delay 1Second

16

800Hz~1200Hz Sweeping at 2Hz

36

600Hz~800Hz

Alternating at 2Hz

56

2400Hz~2600Hz Calling, Delay 1Second

17

1400Hz~1800Hz Sweeping at 0.5Hz

37

900Hz~1100Hz

Alternating at 0.5Hz

57

7 short 1 long

18

1400Hz~1800Hz

Sweeping at 1Hz

38

900Hz~1100Hz Alternating at 1Hz

19

1400Hz~1800Hz

Sweeping at 2Hz

39

900Hz~1100Hz Alternating at 2Hz

20

1800Hz~2400Hz

Sweeping at 2Hz

40

1200Hz~1400Hz Alternating at 2Hz