Series

8800
Pump
RODI P/N: EZ-BP230T-INTL
Flow Range: Open Flow = 1.90-2.60 LPM
At 80 PSI = 1.00-1.40 LPM

Steel Mounting Ppes Available)

3.38

3.60

SPECIFICATIONS:

2.12

n MOTOR:
TYPE:
LEADS:
TEMP. LIMITS:

.23

DUTY CYCLE:
n PUMP DESIGN:

3 Chamber Diaphragm Pump, Self Priming,


Capable of Being Run Dry

n TYPICAL APPLICATION:

Pre-Filter Water Treatment (R.O. Boost)

n MATERIALS:
HOUSINGS:
VALVES:
DIAPHRAGM:
FASTENERS:

Nylon
EPDM
Santoprene
Stainless Steel

n LIQUID TEMPERATURE:

170F (77C) Max.

n PUMP CERTIFICATIONS:

NSF Standard 58

.45

2.75

2.87

7.28

24 VAC, Permanent Magnet,


Totally Enclosed, Non-Ventilated
20 AWG, 6 LONG
This Motor is Not Equipped with Thermal
Protection. For User Safety, Optimal
Performance, and Maximum Motor Life, The
Motor Surface Temperature Should Not Exceed
150F (66C), as Shown on the Heat Rise Graph.
See Heat Rise Graph

2.36
2.25

n PRIMING CAPABILITIES:
PRIME
(FEET)

88X0

88X1

88X2

3.18
4.00

n FITTINGS:

TYPE
3/8" COMPRESSION
3/8" COMPRESSION
3/8" STEM

SHAPE

KIT NO.

STRAIGHT

25-145

CONNECTS TO
3/8" TUBING

ELBOW

25-146

3/8" TUBING

STRAIGHT

25-144

3/8" JOHN GUEST PUSH-ON FITTING

WEIGHT: 6 lbs.

RODI Systems Corp.


936 Hwy 516
Aztec, NM 87410
Phone: 505-334-5865
Fax: 505-334-5867

DOCUMENT:
ISSUED:
REVISED:

DS88XX-2X03-A424
10/20/99
12/9/99

Series 8800 Pump


RODI P/N: EZ-BP230T-INTL
PERFORMANCE DATA
DISCHARGE
PRESSURE
(PSI)
80
70
60
50
40
30
20
10
OPEN

88X0
CURRENT
FLOW
(LPM)
(AMPS)

PUMPHEAD MODEL
88X1
FLOW
CURRENT
(LPM)
(AMPS)

RECOMMENDED
BY-PASS PRESSURE
88X2
FLOW CURRENT
PSI
CODE
(LPM)
(AMPS)

1.00

1.20

1.20

1.40

1.40

1.65

1.10
1.20

1.14
1.06

1.30
1.40

1.29
1.19

1.50
1.60

1.55
1.43

1.30
1.40

0.98
0.90

1.50
1.55

1.10
0.99

1.80
1.90

1.50
1.55

0.82
0.72

1.70
1.85

0.89
0.77

1.80
1.90

0.60
0.53

2.00
2.10

0.64
0.58

110
100

J
I

1.29
1.17

90
80
70

H
G
F

2.00
2.20

1.02
0.91

60
50

E
D

2.50
2.60

0.75
0.70

40
30

B
A

PERFORMANCE MEASURED WITH FLOODED INLET (0 PSI), 70F (21C) AMBIENT AND WATER TEMPERATURE, AND VOLTAGE CONTROLLED AT 24 VAC. POSITIVE INLET PRESSURE WILL INCREASE THE DISCHARGE PRESSURE BY A SIMILAR
AMOUNT, FOR A GIVEN FLOW. MAXIMUM INLET PRESSURE IS 60 PSI.
SHADED AREA DENOTES CONTINUOUS OPERATION CAPABILITY AT DESIGNATED PRESSURE AND CURRENT.

HEAT RISE
200
RECOMMENDED
SHUT-OFF
TEMPERATURE

180
160
140

1.65 AMPS
120
100
80
60
0

10

20

30

40

50

60

70

80

90

100

110

120

TIME (MINUTES)

All of the pump models in the Performance Data and Heat Rise charts are in the shaded area, meaning they are capable of
sustaining continual running, at any of the above listed pressures, without shutting down to allow the motor to cool. To
conserve wearing parts, however, the pump should only operate as needed.
Care should be exercised in selecting the proper transformer for this 24 VAC motor. The largest wall mount transformer
is only rated to .80 amps. The table top transformer is rated to 2.00 amps. By-Pass pressures must
also be considered when selecting a suitable transformer, in the event the pump is allowed to reach the preset by-pass pressure for sustained periods.
ALL PERFORMANCE AND HEAT RISE FIGURES ARE APPROXIMATE. ACTUAL VALUES WILL VARY WITH AMBIENT CONDITIONS.