You are on page 1of 32

Ed.

00

Method of Procedure
SC520.1 LSMR Procedures for SCFT

Date of Release:31-Oct-2014

Prepared By: Gaurav Gupta


Reviewed By: Mr. Hiren Joshi

1|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

COPYRIGHT
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright.
No information contained herein may be copied, translated, transcribed or duplicated for any commercial
purposes or disclosed to the third partyin any form without the prior written consent of SAMSUNG
Electronics Co., Ltd.

TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their
respective companies.

2|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

Document History
Edition

Date of Issue

Author

Remarks

00

31-Oct-2014

Gaurav Gupta

New Document

3|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Troubleshooting flow

Table of Contents

Part I
(Pre-Checks During SCFT)

1.

Remote Electrical Tilt

2.

Physical Cell ID

3.

MIMO Configuration

4.

Track Area Code

5.

Alarm List

6.

RRH Lock / Unlock

7.

SON ANR

8.

EARFCN for UL & DL

Part-II
(Checks During SCFT)
1.

OCNS Testing During SCFT

2.

eNB

3.

Smart Scheduler On/Off.

Internal Neighbour Relation Ship

SAMSUNG Electronics Co., Ltd.

page 4 of 32

Change EARFCN Value/ Ed 00

Part I
(Pre-Checks During SCFT)

1.

Remote Electrical Tilt

2.

Physical Cell ID

3.

MIMO Configuration

4.

Track Area Code

5.

Alarm List

6.

RRH Lock / Unlock

7.

SON ANR

8.

EARFCN for UL & DL

5|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

1)

Remote Electrical Tilt (RET)

1) How to check RET values: Write RTRV-RET-INF in command line and then click on Execute
option.
2)
Note:
b)

a) No need to fill any values

appeared after selecting the command.

In Response Window :

Connect_Bord_ID represent L9CA card; 0 means first L9CA card just above the UAMA Card .
Connect_Port_ID (0,1,2) represents the port sector on the Card

6|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

b) How to Change RET Values: Write CHG-RET-INF in command line and


values before
Connect_BOA

= 0

click on Execute option.


(for first L9CA Card)

Connect_POR=0/1/2
ALD_ID

ANT_ID=1
Remember:

Tilt = Value in degree * 10.

For Example: if value in degree=2,


Then Tilt = 2*10 =20 RET Degree.

7|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

fill

following

Change EARFCN Value/ Ed 00

2) Physical Cell ID (PCI)

1) How to check PCI values: Write RTRV-CELL-IDLE in command line and then click on Execute
option.

Note:

No need to fill any values

8|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Change PCI Values: Write CHG-CELL-IDLE in command line and


values before

Remember :

fill

following

click on Execute option.

A) SON ANR function should be off before executing the command.


B) Sector should be locked before executing the command.

Cell_Num =0

andPHY_Cell_ID = Enter Required Value

and

then Click on Execute.

Cell_Num =1

andPHY_Cell_ID = Enter Required Value

and

then Click on Execute.

Cell_Num =2

andPHY_Cell_ID = Enter Required Value

and

then Click on Execute.

Note:Cell_Num = 0,1,2

represents

9|P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

sector 1,2,3

Change EARFCN Value/ Ed 00

3) MIMO Configuration (Mode & Type)

1) How to check MIMO Configuration: Write RTRV-DL-SCHED in command line and then click on
Execute option.

Note:

No need to fill any values

10 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Change MIMO Configuration: Write CHG-DL-SCHED in command line and


following values before

fill

click on Execute option.

Cell_Num =0

and

DL_MIMO_MODE = TM3 or TM4

and

then Click on Execute.

Cell_Num =1

and

DL_MIMO_MODE = TM3 or TM4

and

then Click on Execute.

Cell_Num =2

and

DL_MIMO_MODE = TM3 or TM4

11 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

and

then Click on Execute.

Change EARFCN Value/ Ed 00

4) Tracking Area Code (TAC)

ID

1) How to check TAC ID : Write RTRV-DL-SCHED in command line and then click on Execute
option.

Note:

No need to fill any values

12 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Change TAC ID: Write CHG-CELL-INF in command line and


before

fill

following values

click on Execute option.

Cell_NUM = 0/1/2
Cell_Size = Very Small,Large etc.
Tracking_Area = Put required TAC
Note:

In case if we are changing TAC the same should be changed in MME also.

13 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

5) Check Alarm List


1) How to check Alarm List : Write RTRV-ALM-List in command line and then click on Execute
option.

Note:

No need to fill any values

14 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

6) RRH

Lock/UnLock

Select eNB SAP ID as mentioned below and right click on mouse a table will open in which a option
called Administrative State will appear .
Click on Locked in order to off the RRH and Unlocked in order to On the RRH as mentioned below.

15 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

7) SON ANR
1) How to check SON ANR : Write RTRV-SONFN-CELL in command line and then click on
Execute option.
Note:

No need to fill any values

16 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Enable SON ANR : Write CHG-SONFN-CELL in command line and drfine following
parametrs before

click on Execute option.

CELL_NUM = 0/1/2
ANR_ENABLE = Auto

17 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

8) EARFCN

1) How to check EARFCN for UL & DL : Write RTRV-EUTRA-FA in command line and then click
on Execute option.

Note:

No need to fill any values

18 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2.1) How to Change EARFCN for UL & DL : Write following command CHG-EUTRA-F
A in command line define following parameters before execute the command.

a) CELL_NUM = 0/1/2
b) FA_INDEX = 0 (always)
c) EARFCN_UL & EARFCN_DL : put decided value
Note: after execute 2.1 go to 2.2

19 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

2.1) How to Change EARFCN for UL & DL: Write following command CHG-CELL-IDLE
in command line define following parameters before execute the command.
a) CELL_NUM = 0/1/2
b) EARFCN_DL = Put decided value
c)

EARFCN_UL = Put decided value

20 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

Part-II
(Checks During SCFT)

1.

Smart Scheduler On/Off.

2.

OCNS Testing During SCFT

3.

eNB Internal Neighbour Relationship

21 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

1) Smart Scheduler On/Off.


How to OFF Smart Scheduler :
a)

Write CHG-SCHRSERV-INF in command line and Select Administrative = schrlocked then


click on Execute option

22 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

b)

Write CHG-CELLSCHR-CONF in command line and Select CELL_NUM=0/1/2


ART_CELL=False then click on Execute option.

23 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

&SM

Change EARFCN Value/ Ed 00

2) How to On Smart Scheduler :

a)

Write CHG-SCHRSERV-INF in command line and Select Administrative = schrunlocked


then click on Execute option

24 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

b)

Write CHG-CELLSCHR-CONF in command line and Select CELL_NUM=0/1/2


SMART_CELL=True then click on Execute option.

25 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

&

Change EARFCN Value/ Ed 00

2) OCNS Testing

1) OCNS Loading : Write Test-OCNS in command line and define following parameters

a) SUB_CELL_NUM = 0/2/4
b) Modulation

= select decided value

c)

= select decided value

26 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Cell Load

Change EARFCN Value/ Ed 00

2) Terminating OCNS Testing :Write Term-Test in command line and define INVOCATION_ID
mentioned below.

INVOCATION_ID = 0/1/2 + Execute

27 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

3) eNB Internal Neighbour Relationship

Step-1:

Select Configuration

28 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

and then go to Neighbour option

Change EARFCN Value/ Ed 00

Step-2:
b)
c)

a)

Select Target eNB

Check Target eNB SAP ID is appear below NeighbourRelation Info.


Go to CELL_NUM and select cell/Sector

29 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

Step-3: Let us consider we select sector-0 then we can see that the remaining sectors are appearing
as aneighbour of sector-0 in Target_Cell_Num

30 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

31 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

32 | P a g e
NEO eNB Part (R4G Project)
SAMSUNG Electronics Co., Ltd.

You might also like