You are on page 1of 10

Job Information

Engineer
Name:
Date:

Checked

Approved

14-Feb-16

Structure Type

SPACE FRAME

Number of Nodes
Number of Elements
Number of Plates

173
286
0

Highest Node
Highest Element
Highest Plate

Number of Design Groups


Number of Design Slabs
Number of Load Cases
Number of Design Briefs

173
286
0

11
0
12
1

Included in this printout are data for:


Design Group
G2: G3

Design Brief

Design Code

B1: Beam

Members

ACI 318M-05 Beam

M3

Design Group Summary - G3


Member

Design

M3

Initial

Span

Type
1
2
3
4

Beam
Beam
Beam
Beam

Main Bars
Hog
Sag
Ok
Ok
Ok
Ok
Ok
Ok
Ok
Ok

Shear
Bars
Ok
Ok
Ok
Ok

Span
Depth
Ok
Ok
Ok
Ok

Summary: the group is safe

Beam Spans

Member
M3

Span

Type
1
2
3
4

Beam
Beam
Beam
Beam

Length
(m)
4.200
1.800
1.800
4.025

Top
(cm)
4.0
4.0
4.0
4.0

Cover
Btm
(cm)
4.0
4.0
4.0
4.0

Beam Supports
Member

Node

M3

N49
N130
N50
N138
N52

Member 3 - Shear Results Summary

Length
(m)
4.200
1.800
1.800
4.025

Support
Type
Fixed
Simple
Fixed
Simple
Fixed

Col. Width
(cm)
40.0
0.0
40.0
0.0
40.0

Side
(cm)
4.0
4.0
4.0
4.0

Link Size
#10
#10
#10
#10

Distance
(m)

Span

Vu
(kN)

Vc
(kN)

Av Required
(mm2)

0.000
0.200
0.350
0.700
1.050
1.400
1.750
2.100
2.450
2.800
3.150
3.500
3.850
4.200
4.200
4.350
4.500
4.650
4.800
4.950
5.100
5.250
5.400
5.550
5.700
5.800
5.850
6.000
6.000
6.150
6.200
6.300
6.450
6.600
6.750
6.900
7.050
7.200
7.350
7.500
7.650
7.800
7.800
8.135
8.471
8.806
9.142
9.477
9.813
10.148
10.483
10.819
11.154
11.490
11.625
11.825

1(s)
1
1
1
1
1
1
1
1
1
1
1
1
1(e)
2(s)
2
2
2
2
2
2
2
2
2
2
2
2
2(e)
3(s)
3
3
3
3
3
3
3
3
3
3
3
3
3(e)
4(s)
4
4
4
4
4
4
4
4
4
4
4
4
4(e)

102.998
98.850
95.740
86.310
77.190
67.449
53.055
41.453
29.851
15.457
5.717
12.600
22.030
29.288
99.955
102.990
106.423
109.800
113.291
117.636
121.469
125.301
129.646
133.137
136.514
138.803
139.947
142.982
132.097
129.063
127.918
125.629
122.252
118.762
114.416
110.584
106.751
102.406
98.915
95.539
92.105
89.070
20.576
13.633
4.985
13.638
22.861
36.358
47.291
58.224
71.721
80.944
89.597
98.535
101.338
105.478

0.000
99.356
99.356
99.356
99.356
99.719
99.719
99.719
99.719
99.719
99.719
99.719
99.719
99.719
101.082
101.082
101.082
101.082
100.714
100.714
100.714
100.714
100.714
100.714
100.714
100.714
0.000
0.000
0.000
0.000
99.545
99.545
99.545
99.545
99.545
99.545
99.545
99.908
99.908
99.908
99.908
99.908
101.245
101.245
101.245
101.245
101.245
101.245
101.245
101.245
101.245
100.877
100.877
100.877
100.877
0.000

0
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
78
86
93
99
104
0
0
0
0
85
80
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
0

Summary: the member is safe

Span / Depth
Member
M3

Span
1

Length
(m)
4.200

Type
Beam

Basic
Limit
18.5

Modified
Limit
14.7

Span
Depth
8.4

2
3
4

1.800
1.800
4.025

Beam
Beam
Beam

18.5
18.5
18.5

14.7
14.7
14.7

3.6
3.6
8.0

Summary: the group is safe

Member M3 Span 1
Detailed ACI Design Requirements
Section Property: 300 x 500
Span Length
= 4.200 Rectangular section
Width
= 300 mmDepth
= 500 mm
Covers: Top = 40 mm Bottom = 40 mm Side = 40 mm

Member M3 Span 1
Detailed ACI Main Reinforcement
Hogging: at 0.200 m from the start of the member
Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

= 97.73 kNm
d
= 438 mm
d'
= 62 mm
= 4.78

Rnt
= 1.89
= 955.5 mm2
= 2#25

= 1020 mm2
= 0.51 % 10.5
= 0.78 %

Minimum horizontal distance between top bars


Smallest actual horizontal space between top bars

= 33 mm 3.3.2(c)&7.6.1
= 150 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 176 mm

Actual neutral axis depth in section


Moment capacity of section

= 61.62 mm
= 103.91 kNm
OK

Sagging: at 3.500 m from the start of the member


Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

Rnt
= 1.25
= 622.3 mm2
= 2#22

Minimum horizontal distance between bottom bars


Smallest actual horizontal space between bottom bars
Maximum spacing of tension bars, s

= 65.21 kNm
d
= 439 mm
d'
= 62 mm
= 4.78

= 774 mm2
= 0.51 % 10.5
= 0.59 %
= 33 mm 3.3.2(c)&7.6.1
= 157 mm

= 380 (280/fs) - 2.5cc 300(280/fs)


Largest actual space between tension bars

= 458.18 mm
10.6.4
= 179 mm

Actual neutral axis depth in section


Moment capacity of section

= 46.76 mm
= 80.37 kNm
OK

Member M3 Span 1
Detailed ACI Span / Depth Check
Basic span / depth ratio
= 18.50
Strength modification factor = 0.4 + fy / 700
Hence, modified span / depth ratio
Actual span / depth ratio
= 8.40
OK

9.5.2.1
= 0.79
= 14.67

Member M3 Span 1
Detailed ACI Shear Reinforcement
High shear zone: 0.200 m to 4.199 m
Actual spacing of ties, s
= 200 mm
Design axial force, Nu
= -14.98 kNm
Shear force, Vu
= 98.85 kN
Vc = 0.17 [1 + (0.29 Nu/Ag)] fc' bw d
= 99.36 kN
11.2&11.3
required (Av/s)
= (Vu - Vc/fytd)
R11.5.7
= (98850.34 - 0.85 99356.02/0.85 275 437.8)= 140.7 mm2/m
Av, min

= 0.062 fc'(bws/fyt) = 62.0 mm2


(0.35 bws) / fyt
= 76.4 mm2

area of links provided (2#10), Av


Maximum spacing of ties
OK

(11-13)
11.5.6.3

= 142.0 mm2
= 219 mm11.5.5.1&11.5.5.3

Member M3 Span 2
Detailed ACI Design Requirements
Section Property: 300 x 500
Span Length
= 1.800 Rectangular section
Width
= 300 mmDepth
= 500 mm
Covers: Top = 40 mm Bottom = 40 mm Side = 40 mm

Member M3 Span 2
Detailed ACI Main Reinforcement
Sagging: at 4.200 m from the start of the member
Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)

Rnt
= 1.06

= 55.40 kNm
d
= 439 mm
d'
= 62 mm
= 4.78

= 525.5 mm2
= 2#22

As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

= 774 mm2
= 0.51 % 10.5
= 0.59 %

Minimum horizontal distance between bottom bars


Smallest actual horizontal space between bottom bars

= 33 mm 3.3.2(c)&7.6.1
= 157 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 179 mm

Actual neutral axis depth in section


Moment capacity of section

= 46.76 mm
= 80.37 kNm
OK

Hogging: at 5.800 m from the start of the member


Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

= 145.61 kNm
d
= 438 mm
d'
= 62 mm
= 4.78

Rnt
= 2.81
= 1470.7 mm2
= 3#25

= 1530 mm2
= 0.51 % 10.5
= 1.16 %

Minimum horizontal distance between top bars


Smallest actual horizontal space between top bars

= 33 mm 3.3.2(c)&7.6.1
= 62 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 88 mm

Actual neutral axis depth in section


Moment capacity of section

= 92.44 mm
= 150.91 kNm
OK

Member M3 Span 2
Detailed ACI Span / Depth Check
Basic span / depth ratio
= 18.50
Strength modification factor = 0.4 + fy / 700
Hence, modified span / depth ratio
Actual span / depth ratio
= 3.60
OK

9.5.2.1
= 0.79
= 14.67

Member M3 Span 2
Detailed ACI Shear Reinforcement
High shear zone: 4.199 m to 5.800 m
Actual spacing of ties, s
Design axial force, Nu
Shear force, Vu

= 200 mm
= -8.11 kNm
= 138.80 kN

Vc = 0.17 [1 + (0.29 Nu/Ag)] fc' bw d


= 100.71 kN
required (Av/s)
= (Vu - Vc/fytd)
R11.5.7
= (138802.86 - 0.85 100713.57/0.85 275 437.8)
Av, min

= 0.062 fc'(bws/fyt) = 62.0 mm2


(0.35 bws) / fyt
= 76.4 mm2

11.2&11.3
= 519.8 mm2/m

(11-13)
11.5.6.3

= 142.0 mm2
= 219 mm11.5.5.1&11.5.5.3

area of links provided (2#10), Av


Maximum spacing of ties
OK

Member M3 Span 3
Detailed ACI Design Requirements
Section Property: 300 x 500
Span Length
= 1.800 Rectangular section
Width
= 300 mmDepth
= 500 mm
Covers: Top = 40 mm Bottom = 40 mm Side = 40 mm

Member M3 Span 3
Detailed ACI Main Reinforcement
Hogging: at 6.200 m from the start of the member
Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

= 117.10 kNm
d
= 438 mm
d'
= 62 mm
= 4.78

Rnt
= 2.26
= 1159.6 mm2
= 3#25

= 1530 mm2
= 0.51 % 10.5
= 1.16 %

Minimum horizontal distance between top bars


Smallest actual horizontal space between top bars

= 33 mm 3.3.2(c)&7.6.1
= 62 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 88 mm

Actual neutral axis depth in section


Moment capacity of section

= 92.44 mm
= 150.91 kNm
OK

Sagging: at 7.800 m from the start of the member


Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement

= 68.44 kNm
d
= 439 mm
d'
= 62 mm
= 4.78

Rnt
= 1.31
= 654.3 mm2
= 2#22

= 774 mm2
= 0.51 % 10.5

Actual % of tension reinforcement

= 0.59 %

Minimum horizontal distance between bottom bars


Smallest actual horizontal space between bottom bars

= 33 mm 3.3.2(c)&7.6.1
= 157 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 179 mm

Actual neutral axis depth in section


Moment capacity of section

= 46.76 mm
= 80.37 kNm
OK

Member M3 Span 3
Detailed ACI Span / Depth Check
Basic span / depth ratio
= 18.50
Strength modification factor = 0.4 + fy / 700
Hence, modified span / depth ratio
Actual span / depth ratio
= 3.60
OK

9.5.2.1
= 0.79
= 14.67

Member M3 Span 3
Detailed ACI Shear Reinforcement
High shear zone: 6.200 m to 7.799 m
Actual spacing of ties, s
= 200 mm
Design axial force, Nu
= -14.02 kNm
Shear force, Vu
= 127.92 kN
Vc = 0.17 [1 + (0.29 Nu/Ag)] fc' bw d
= 99.54 kN
required (Av/s)
= (Vu - Vc/fytd)
R11.5.7
= (127918.18 - 0.85 99544.55/0.85 275 437.8)
Av, min

= 0.062 fc'(bws/fyt) = 62.0 mm2


(0.35 bws) / fyt
= 76.4 mm2

area of links provided (2#10), Av


Maximum spacing of ties
OK

Member M3 Span 4
Detailed ACI Design Requirements
Section Property: 300 x 500
Span Length
= 4.025 Rectangular section
Width
= 300 mmDepth
= 500 mm
Covers: Top = 40 mm Bottom = 40 mm Side = 40 mm

Member M3 Span 4
Detailed ACI Main Reinforcement
Sagging: at 8.135 m from the start of the member

(11-13)
11.5.6.3

= 142.0 mm2
= 219 mm11.5.5.1&11.5.5.3

11.2&11.3
= 423.2 mm2/m

Moment applied to section


Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

= 72.09 kNm
d
= 439 mm
d'
= 62 mm
= 4.78

Rnt
= 1.38
= 690.7 mm2
= 2#22

= 774 mm2
= 0.51 % 10.5
= 0.59 %

Minimum horizontal distance between bottom bars


Smallest actual horizontal space between bottom bars

= 33 mm 3.3.2(c)&7.6.1
= 157 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 179 mm

Actual neutral axis depth in section


Moment capacity of section

= 46.76 mm
= 80.37 kNm
OK

Hogging: at 11.625 m from the start of the member


Moment applied to section
Effective depth of tension reinforcement
Depth to compression reinforcement
Limit for compression steel
Rn
= (Mu/bd2)
As
= (M/fy z)
Tension Bars provided
Actual area of tension reinforcement
Minimum area of tension reinforcement
Actual % of tension reinforcement

= 100.35 kNm
d
= 438 mm
d'
= 62 mm
= 4.78

Rnt
= 1.94
= 982.7 mm2
= 2#25

= 1020 mm2
= 0.51 % 10.5
= 0.78 %

Minimum horizontal distance between top bars


Smallest actual horizontal space between top bars

= 33 mm 3.3.2(c)&7.6.1
= 150 mm

Maximum spacing of tension bars, s


= 380 (280/fs) - 2.5cc 300(280/fs)
Largest actual space between tension bars

= 458.18 mm
10.6.4
= 176 mm

Actual neutral axis depth in section


Moment capacity of section

= 61.62 mm
= 103.91 kNm
OK

Member M3 Span 4
Detailed ACI Span / Depth Check
Basic span / depth ratio
= 18.50
Strength modification factor = 0.4 + fy / 700
Hence, modified span / depth ratio
Actual span / depth ratio
= 8.05
OK

Member M3 Span 4
Detailed ACI Shear Reinforcement

9.5.2.1
= 0.79
= 14.67

High shear zone: 7.799 m to 11.625 m


Actual spacing of ties, s
= 200 mm
Design axial force, Nu
= -7.29 kNm
Shear force, Vu
= 101.34 kN
Vc = 0.17 [1 + (0.29 Nu/Ag)] fc' bw d
= 100.88 kN
required (Av/s)
= (Vu - Vc/fytd)
R11.5.7
= (101338.19 - 0.85 100876.60/0.85 275 437.8)
Av, min

= 0.062 fc'(bws/fyt) = 62.0 mm2


(0.35 bws) / fyt
= 76.4 mm2

area of links provided (2#10), Av


Maximum spacing of ties
OK

(11-13)
11.5.6.3

= 142.0 mm2
= 219 mm11.5.5.1&11.5.5.3

11.2&11.3
= 152.4 mm2/m