You are on page 1of 3

Shell and Coil Heat Exchangers for the HVAC Industry

Page 1 of 2

heat exchangers home | history | technical papers | products | contact us | research | sitemap
- brazed | double wall brazed | shell and tube | shell & coil | pool heaters | indirect water heaters
- applications: radiant floor heating | snow melting systems | district heating

Shell and Coil Heat Exchangers


The shell and coil heat exchangers are constructed using circular
layers of helically corrugated tubes placed inside a light compact shell.
The fluid in each layer flows in the opposite direction to the layer
surrounding it, producing a criss-cross pattern. The large number of
closely packed tubes creates a significant heat transfer surface within a
light compact shell. The alternate layers create a swift uniform heating of
fluids increasing the total heat transfer coefficient. The corrugated tubes
produce a turbulent flow where the desired feature of fluctuating
velocities is achieved. This haphazard movement of fluid particles
reduces deposit buildup by performing a "scoop and lift" action. The
connection locations and angle of entry is specially selected to reduce
the probability of debris buildup.

Click Here For Complete Product Specifications


Shell and Coil Construction Features
The shell and coil tube series are manufactured as a singe unit with no removable parts. The coiled tube bundles
welded to a compact tube sheet located within the entry and exit connections. The cylindrical shell is terminated by
spherical heads. Design variations include smooth or grooved tubes, angled or 90 connections in flanged or NPT
termination, and 316L stainless or titanium components.
Advantages of the shell and coil heat exchangers:
The shell and coil design is the perfect choice whenever high heat transfer rates, compact design and low mainten
costs are high priorities. Other benefits include:
z

High Performance: the unique coil arrangement has a large heat transfer area meaning high heat transfer
coefficients.
Compact and Lightweight: closely packed tubes makes our shell and coil exchangers compact and
lightweight. Small footprint makes it easy to install where space is limited and hard to access.
Low Maintenance Costs: corrugated tube design produces a high turbulent flow, which reduces deposit
up and fouling. This means longer operating cycles between scheduled cleaning intervals.

Low Installation Costs: vertical installation makes it ideal for hydronic heating and cooling systems where
is an issue.
Higher Temperature Differentials: helical design allows for higher temperatures and extreme temperature
differentials without high stress levels and costly expansion joints.
Flexible Designs: variety of model types and configurations allow shell and coil heat exchangers to be use
a wide range of pressures, temperatures, and flows.
Low Pressure Drop:

Easy selection based on sub-station space requirements and heat or cooling load.

Units kept in stock for immediate delivery.

Shell and Coil Applications:


The shell and coil design were designed specifically for the hydronic markets including:

http://www.heatexchangersonline.com/shellandcoil.htm

7/6/2005

Shell and Coil Heat Exchangers for the HVAC Industry

Page 2 of 2

Heating Systems:

Chilled Water Systems:

Ground Water Systems:

Residential Use:

District Heating Systems: heating systems that distribute heat from one or more heating sources to multip
buildings.

Please note that all our heat exchangers are available for immediate delivery.
Do you still have questions? We invite you to call or email us today for more information. We'll be happy to provide
with a heat exchanger that matches your specific needs.
Call us today: 416.557.1067 or by Email: info@heatexhangersonline.com
a
heat exchangers home | history | products | brazed | shell & tube | shell & coil | pool heaters | technical papers | contact us | research | sitem
a
Copyright 2005 | Heat Exchangers Online | All Rights Reserved
a
Thermal Solutions Inc ~ P.O. Box 12033 ~ 2B-848 Burnhamthorpe Road W ~ Mississauga ~ ON ~ L5C 4R7
Phone: 416.557.1067 ~ Email: info@heatexchangersonline.com

http://www.heatexchangersonline.com/shellandcoil.htm

7/6/2005

Shell & Coil Technical Parameters - Heat Exchangers Online

Page 1 of 2

helically corrugated tubes

* with support legs

smooth tubes

** NPT connections up to 1.5 in 2 in and above - die fored flangers compatible to


CL300

Shell & Coil Parameters


Volume
Type

H-0K

Mounting Dimesions

Dia

Heat Tranfer
Area

Weight

Shellside

Tubeside

Height

Width

Shell

sqr ft (m2)

lb (kg)

gal (l)

gal (l)

in (mm)

in (mm)

in (mm)

3.12 (0.29)

11.0 (5.0)

0.3 (1.0)

0.13 (0.50)

23.03 (585)

3.94 (100)

3.15 (80.0)

H-1K

8.19 (0.76)

17.6 (8.0)

0.6 (2.4)

0.29 (1.10)

31.50 (800)

4.33 (110)

4.00 (101.6)

H-2K

14.21 (1.32)

22.0 (10.0)

0.8 (3.0)

0.50 (1.90)

41.73 (1060)

4.33 (110)

4.00 (101.6)

JAD x 2.11

112.92 (1.20)

43.0 (19.5)

0.7 (2.6)

0.60 (2.26)

59.57 (1513)

6.30 (160)

3.15 (80.0)

JAD x 3.18

21.53 (2.00)

61.7 (28.0)

1.3 (5.0)

1.06 (4.00)

59.45 (1510)

6.77 (172)

4.00 (101.6)

JAD x 5.38

43.06 (4.00)

95.9 (43.5)

3.0 (11.4)

1.75 (6.63)

59.45 (1510)

8.03 (204)

5.50 (139.7)

JAD x 6.50

61.35 (5.70)

121.3 (55.0)

3.6 (13.6)

2.96 (11.20)

58.74 (1492)

8.11 (206)

6.26 (159.0)

JAD x 9.88

115.17 (10.70)

209.4 (95.0)

7.7 (29.0)

4.23 (16.00)

58.31 (1481)

9.96 (253)

8.63 (219.1)

JAD x 12.114

198.06 (18.40)

330.7 (150.0)

14.3 (54.2)

5.31 (20.10)

66.34 (1685)

13.39 (340)

10.75 (273.0)

JAD x 17.217.10

376.74 (35.00)

925.9 (420.0)

63.14 (239.0)

20.50 (77.60)

84.25 (2140)*

26.38 (670)

20.00 (508.0)

JAD x K 2.11

12.92 (1.20)

43.0 (19.5)

0.7 (2.6)

0.60 (2.26)

59.57 (1513)

6.30 (160)

3.15 (80.0)

JAD x K 3.18

21.53 (2.00)

61.7 (28.0)

1.3 (5.0)

1.06 (4.00)

59.45 (1510)

6.77 (172)

4.00 (101.6)

S-OXK

24.76 (2.30)

63.9 (29.0)

1.6 (6.2)

0.87 (3.30)

35.87 (911)

8.03 (204)

5.50 (139.7)

S-IXK

33.80 (3.14)

77.2 (35.0)

2.6 (9.8)

1.19 (4.50)

39.09 (993)

8.11 (206)

6.26 (159.0)

JAD x K 5.38

43.06 (4.00)

95.9 (43.5)

3.0 (11.4)

1.75 (6.63)

59.45 (1510)

8.03 (204)

5.50 (139.7)

JAD x K 5.38.08.71

24.76 (2.30)

54.0 (24.5)

1.8 (6.8)

1.06 (4.04)

35.87 (911)

8.03 (204)

5.50 (139.7)

JAD x K 6.50

61.35 (5.70)

121.3 (55.0)

3.6 (13.6)

2.96 (11.20)

58.74 (1492)

8.11 (2.06)

6.26 (159.0)

JAD x K 6.50.10

54.89 (5.10)

116.8 (53.0)

3.7 (14.2)

2.80 (10.60)

58.74 (1492)

8.11 (2.06)

6.26 (159.0)

JAD x K 6.50.08.72

33.80 (3.14)

77.2 (35.0)

2.6 (.9.8)

1.19 (4.50)

35.94 (913)

8.11 (2.06)

6.26 (159.0)

JAD x K 9.88

115.17 (10.70)

209.4 (95.0)

7.7 (29.0)

4.23 (16.00)

58.31 (1481)

9.96 (253)

8.63 (219.1)

JAD x K 9.88.10

89.34 (8.30)

198.4 (90.0)

8.5 (32.0)

3.43 (13.00)

58.31 (1481)

9.96 (253)

8.63 (219.1)

JAD x K 9.88.12

73.41 (6.82)

198.4 (90.0)

7.9 (30.0)

4.22 (16.00)

58.31 (1481)

9.96 (253)

8.63 (219.1)

JAD x K 9.88.08.85

66.74 (6.20)

127.4 (57.8)

6.6 (25.0)

2.17 (8.20)

42.76 (1086)

9.96 (253)

8.63 (219.1)

JAD x K 9.88.08.65

53.50 (4.97)

117.5 (53.3)

5.5 (20.8)

1.74 (6.60)

34.88 (886)

9.96 (253)

8.63 (219.1)

JAD x K 12.114

198.06 (18.40)

330.7 (150.0)

14.3 (54.2)

5.31 (20.10)

66.34 (1685)

13.39 (340)

10.75 (273.0)

JAD x K 12.114.10
JAD x K 12.114.12

160.38 (14.90)
113.02 (10.50)

313.1 (142.0)
291.0 (132.0)

14.5 (55.0)
14.7 (55.8)

5.10 (19.30)
4.89 (18.50)

66.34 (1685)
66.34 (1685)

13.39 (340)
13.39 (340)

10.75 (273.0)
10.75 (273.0)

JAD x K 12.114.08.75

94.51 (8.78)

170.9 (77.5)

10.2 (38.5)

2.64 (10.00)

40.59 (1031)

13.39 (340)

10.75 (273.0)

JAD x K 12.114.08.60

69.53 (6.46)

150.1 (68.1)

9.0 (34.0)

2.14 (8.10)

34.68 (881)

13.39 (340)

10.75 (273.0)

JAD x K 12.114.08.50
JAD x K
14.163.08.121
JAD x K
14.163.10.121
JAD x K
14.163.12.121

67.27 (6.25)

146.4 (66.4)

7.7 (29.0)

2.11 (8.00)

30.75 (781)

13.39 (340)

10.75 (273.0)

265.90 (24.70)

451.9 (205.0)

12.8 (48.60

10.40 (39.40)

88.11 (2238)*

15.04 (382)

12.76 (324.0)

195.90 (18.20)

392.4 (178.0)

13.2 (50.0)

12.52 (47.40)

88.11 (2238)*

15.04 (382)

12.76 (324.0)

168.90 (15.70)

370.4 (168.0)

12.0 (45.5)

11.10 (42.00)

88.11 (2238)*

15.04 (382)

12.76 (324.0)

http://www.heatexchangersonline.com/shellandcoil2.htm

7/6/2005

You might also like