You are on page 1of 3

_

DATA SHEET
Transformer / Transformer Rectifier
The most common type of power supply used for impressed current cathodic protection is a
transformer/rectifier, commonly referred to simply as a rectifier. A rectifier converts the AC power supply
voltage to the required output voltage and then converts it to DC.
YUXI Rectifiers are either supplied in ventilated cases to allow convective air cooling or are immersed in
transformer oil with the following advantages:

Customized specification and function

Up to IP66 dust and water protection

Capable of using all kinds of reference electrodes

Integration and modularization circuit

Excellent relibility and easy maintenance

Accurate readings using high input impedance meters

Excellent circuit and lightening protection

General Specification
1. A.C. Input
2. Frequency
3. D.C. Output Current
4. D.C. Output Voltage
5. Constant potential control range
6. Constant potential control precision
7. Constant current control precision
8. Cooling
9. Ripple
10. Input Impedance
11. Cable Terminations

12. Enclosure

13. Accessories

220-440V 10%, Single/Three Phase


50HZ/60HZ
0-50Amps
0-50Volts
0-1.999V
10mV
1%
Oil Cooling / Air Cooling
7%
5 M
a) DC Output (Positive) 35mm2-2nos.
b) DC Output (Negative) 35mm2-1nos.
c) AC Input 3/4x2.5mm2-1nos.
d) Reference electrode -2nos.
All cable through suitable cable glands
Floor mounted type
IP65 Protection Grade, In door/Out door
Painted Cold-Rolled Steel Sheet
a) Steel channel under the base for floor
mounting
b) Sunshade/rain Shade
c) Locking device
d) Lifting lugs
1600mm x 800mm x 680mm / 280kgs
-5 to +55
Up to 90%

14. Dimension and Weight


15. Ambient temperature range
16. Relative Humidity
Transformer:
The transformer will be isolation type having separate primary and secondary windings in
accordance with IEC76 or BS171.
Rectifier:
Silicon diode full wave bridge rectifier
Control:
Manual / Automatic
The unit will be capable of operating in either Constant Potential Mode or Constant Current
Mode.
The output voltage and output current can be adjustable from 0 to rated value in stepless manner
by means of a setter potentiometer.

Protection:
Rectifier Input and Output overload and short circuit protection is achieved by MCB and HRC
Fuses.
Lightening arrestors in positive and negative 40KA
Lightening arrestors in reference electrode input 10KA
Lightening arrestors in power input 40KA
Meters:
The transformer rectifier is equipped with separate digital continuous reading voltmeters and
ammeter for the DC output voltage, DC output current and Potential measurements.
Spare parts:
a) Instruction Manual 1set
b) Fuse 32A 5pcs
c) Key 2pcs
d) Indication Lamps 1pc
e) Testing Button 1pc
f) Reset Button 1pc
Name plate:
A permanently stamped stainless steel metal plate is attached to outside of the case with the
following information:
a) Manufacturers name
b) AC input and DC output
c) Model number and Serial number
d) Year of Manufacture