You are on page 1of 10

MiniFlex

Super Distribution Amplifiers 1002 MHz

The ACI MiniFlex super distribution RF amplifiers provided high quality RF distribution for
fiber-to-feeder, HFC (hybrid fiber coaxial), or PDN (power domain node) architectures.

Features

1002 MHz may be dropped into the 750


or 870 MHz spacing

Availability of an 85/105 MHz option


that will double the reverse bandwidth

Common 1002 MHz housing platform

15 amp power passing

Optional, 8 or 14 MHz reverse path


rejection filter (sold separately)

CE qualified

Self retracting housing cover bolts

-20 dB directional coupler test points

AGC or thermal or manual options

5 to 42, 55, 65 or 85 MHz reverse path

Plug-in attenuator JXP style pads for


each reverse path

Plug-in equalizers

Test point for each reverse path

Standard push on F connectors can


be used on all test points

Page 1 of 10

www.acicomms.com

SDAT (Type 1A, 1T & 1M) 1002 MHz Amplifier Block Diagram

AC/
RF

P1
Forward Input
Reverse Output

Pad

EQ

Mid/High
Net Board

Pad

EQ

AGC

Pad

BSW

Optional

Forward Gain
33 dB Trunk
42 dB Feeder

Optional
-20 dB
Test Point
Pad

Net
Board

-20 dB
Test Point

Pad

Power
Director
L

AC/
RF

P3

Forward Output
Reverse Input

-20 dB
Test Point

Net
Board

Rejection
Filter

EQ

-20 dB
Test Point

Forward Output
Reverse Input

-20 dB
Power
Test Point Director

Pad

Reverse Gain
18 or 23 dB

P2

Low End
Peaking

-20 dB
Power Test Point
Director

Power
Director

AC/
RF

Net
Board

Pad

Net
Board

Pad

AC/
RF

P4
Forward Output
Reverse Input

-20 dB
Test Point

-20 dB
Test Point

Note:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.

SDAF (Type 2A-TRI, 2T-TRI, 2M-TRI) 1002 MHz Amplifier Block Diagram
H

AC/
RF

P1
Forward Input
Reverse Output

EQ

Pad

Pad

Mid/High
Net Board

AC/
RF

P2

Low End
Peaking

-20 dB
Power Test Point
Director

Fixed
Pad

Pad

Rejection
Filter

EQ

Net
Board

Optional
Reverse Gain
18 or 23 dB

EQ

AGC

-20 dB
Power
Test Point Director

Pad

Forward Output
Reverse Input

-20 dB
Test Point
BSW
Optional

-20 dB
Test Point

Forward Gain
See options
listed below

-20 dB
Test Point
Pad
-20 dB
Test Point

Net
Board

Pad
Power
Director
L

AC/
RF

P3

Forward Output
Reverse Input

Net
Board

Net
Board

Pad

Pad

Power
Director

Plug-in Jumper
Splitter or
Coupler
(DC/SP3)

-20 dB
Test Point

AC/
RF

P4
Forward Output
Reverse Input

-20 dB
Test Point

Notes:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.
2. Amplifiers are configured at the factory with jumper in Position #2 to have P3 & P4 active.
Splitters and Couplers are sold separately.
SDA1G-DC7
TH R U

S D A1 G -D C7

-7dB

SDA1G-DC12
- 1 2d B

TH R U

S D A1 G -D C7

-7dB

S D A1 G - S P L TR3 . 5

S D A1 G - D C1 2

SDA1G-DC7

SDA1G-SPLTR3.5

TH R U

Jumper Position #1 Jumper Position #2


(P2 & P3 active)
(P3 & P4 active)

SDA1G-DC12
TH R U

S D A1 G -D C1 2

- 1 2d B

Port

Fwd Gain (dB)


1002

Port

Fwd Gain (dB)


1002

Port

Fwd Gain (dB)


1002

Port

Fwd Gain (dB)


1002

Port

Fwd Gain (dB)


1002

Port

Fwd Gain (dB)


1002

Port

Fwd Gain (dB)


1002

P2
P3
P4

43.0
43.0
N/A

P2
P3
P4

N/A
43.0
43.0

P2
P3
P4

39.5
43.0
39.5

P2
P3
P4

36.0
43.0
40.5

P2
P3
P4

40.5
43.0
36.0

P2
P3
P4

31.0
43.0
41.0

P2
P3
P4

41.0
43.0
31.0

Page 2 of 10

www.acicomms.com

SDBT (Type 6A, 6T & 6M) 1002 MHz Amplifier Block Diagram

P1
Forward Input
Reverse Output

AC/
RF

Pad

EQ

Mid/High
Net Board

Pad

EQ

AGC

AC/
RF

P2
Forward Output
Reverse Input

Low End
Peaking

-20 dB
Power Test Point
Director

Power
Director

Pad
-20 dB
Test Point
Pad

Net
Board

Rejection
Filter

EQ

Optional

Reverse Gain
18 or 23 dB

-20 dB
Test Point

BSW

Forward Gain
41 dB Feeder

Optional

-20 dB
Test Point
-20 dB
Test Point
Power
Director

P3
Forward Output
Reverse Input

-20 dB
Test Point Power
Director

AC/
RF

Pad

-20 dB
Test Point

Pad

Pad

Pad

AC/
RF

P4
Forward Output
Reverse Input

-20 dB
Test Point

Note:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.

SDAB (Type 2A, 2T & 2M) 1002 MHz Amplifier Block Diagram

P1

AC/
RF

Forward Input
Reverse Output
Power
Director

EQ

Pad

Pad

Mid/High
Net Board

L
-20 dB
Test Point

Pad

Net
Board

Rejection
Filter

EQ

Optional
Reverse Gain
18 or 23 dB

P3

BSW

-20 dB
Test Point

Pad

Pad

Net
Board

-20 dB
Test Point

Power
Director
L

AC/
RF

Forward Gain
43 dB Feeder

Optional

-20 dB
Test Point

Power
Director

Forward Output
Reverse Input

EQ

AGC

Low End
Peaking

Pad

Net
Board

Net
Board

Pad

AC/
RF

-20 dB
Test Point

-20 dB
Test Point

P4
Forward Output
Reverse Input

Note:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.

Page 3 of 10

www.acicomms.com

SDLA (Type 3A, 3T, & 3M Dual) 1002 MHz Amplifier Block Diagram

P1
Forward Input
Reverse Output

AC/
RF

EQ

Pad

Pad

Mid/High
Net Board

EQ

AGC

AC/
RF

P2

Forward
Output
Reverse Input

Low End
Peaking

-20 dB
Power Test Point
Director

Power
Director
-20 dB
Test Point
Pad

Rejection
Filter

EQ

Reverse Gain
18 or 23 dB

BSW

Optional

-20 dB
Test Point

Forward Gain
35.5 dB Feeder

Optional

-20 dB
Test Point
-20 dB
Test Point

Pad

Power
Director
-20 dB
Test Point

L
Pad

AC/
RF

P4
Forward Output
Reverse Input

Note:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.

SDLT (Type 4A, 4T, & 4M) 1002 MHz Amplifier Block Diagram

P1
Forward Input
Reverse Output

AC/
RF

EQ

Pad

Pad

Mid/High
Net Board

AGC

EQ

AC/
RF

L
Low End
Peaking

P2
Forward Output
Reverse Input

Terminated

-20 dB
Power Test Point
Director

Power
Director

Pad
Reverse Gain
18, 21 or 23 dB

EQ

Rejection
Filter

Optional
-20 dB
Test Point

-20 dB
Test Point

BSW

Forward Gain
33 dB Trunk

Optional
-20 dB
Test Point

Note:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.

Page 4 of 10

www.acicomms.com

SDLE (Type 3A, 3T, & 3M) 1002 MHz Amplifier Block Diagram

P1

AC/
RF

Forward Input
Reverse Output
Power
Director

EQ

Pad

Pad

Mid/High
Net Board

AGC

EQ

AC/
RF

Low End
Peaking

P2
Forward Output
Reverse Input

-20 dB
Test Point

Power
Director

Pad
Reverse Gain
18, 21 or 23 dB

EQ

Rejection
Filter

Net
Board

Optional
-20 dB
Test Point

-20 dB
Test Point

BSW

Forward Gain
35.5 dB Feeder

Optional
-20 dB
Test Point

Note:
1. Forward gain stated at 1002 MHz with AGC. Reverse gain stated at 40 MHz.

Page 5 of 10

www.acicomms.com

STATION PARAMETERS:

1002 MHz 42-53 MHz Split


CONDITIONS

Housing passband
Input current capacity

Any port, worst case

UNITS

SPECIFICATIONS

MHz

5 to 1002

Amp

15

Hum modulation

Time domain @
rated current above

-dBc

65 @ 5-40 MHz
69 @ 54-1002 MHz

Return loss

Any port, worst case

dB

18.0

MHz

5 to 40 (Reverse) / 54 to 1002 (Forward)

Test point type

Directional coupler

N/A

Test point level

Forward & reverse

-dB

20.0

Test point accuracy

Forward & reverse

dB

0.5

@ 54 / 550 / 1002 MHz

dB

0 / 9.0 / 17.2

Test Points
Frequency range

Station Slope
Operational slope trunk & feeders
Slope control type

Cable equalizers

dB

Plug-in EQ's

Slope control range

Includes cable equivalent

dB

-12.0 to +30.0

Slope control steps

Equalizer value steps

dB

0 - 18.0 (1.0 steps) & 20.0-30.0 (2.0 steps) -1.0 to -12.0 (1.0 steps)

Station Group Delay


Group delay

Channel 2 (Std)

Group delay

Channel 3

Group delay

Channel 4

Group delay

Channel 5 & >

40 (35 Typical)
16

nSec /
3.58 MHz

10
3
SPAGC Single Pilot Channel AGC

AGC
Pilot Channel Type

DSIM-A Single Pilot Channel AGC

N/A

NTSC Analog

NTSC Analog or QAM

Compensation Range

dB

System compensation input change


+3/-5 @ 1002 MHz

System compensation input change


+3/-6 @ 1002 MHz

Accuracy

dB

0.5

0.5

dB

5.5

6.25

Nominal loss

@ 77 F (25 C)

Center frequency bandwidth

150 (Fc kHz)

Configuration

6 (MHz)

SDAT
(Type 1)

SDAF
(Type 2 Tri)

SDBT
(Type 6)

SDAB
(Type 2)

SDLA
(Type 3 Dual)

SDLT
(Type 4)

SDLE
(Type 3)

Operational Specifications
Station passband

MHz

Station flatness - trunk out

dB

0.35

0.35

dB

0.6

0.75

0.6

0.6

0.6

0.35

Normalized w / 0 dB slope

Station flatness - feeder out


Gain - Port 2 (AGC / Manual)

+0.5 / -0 @ 1002 MHz


(Temperature stabilized)

Gain - Port 3 (AGC / Manual)


Gain - Port 4 (AGC / Manual)
Gain control type
Gain control steps

Pad value steps

54 to 1002

dB

33 / 38

41 / 44

35.5 / 40.5

33 / 38

35.5 / 40.5

dB

42 / 47

43 / 46

41 / 44

43 / 48

dB

42 / 47

43 / 46

41 / 44

43 / 48

35.5 / 40.5

N/A

Plug-in pads

dB

0.5

550 MHz analog channel loading, 79 channels +450 MHz digital channel loading, 256 QAM at -6 dBc relative to its associated visual carrier
SDAT
(Type 1)

Station Output Levels


Port 2
Port 3

@ 54 / 550 / 1002 MHz

dBmV

Port 4

SDAF
(Type 2 Tri)

SDBT
(Type 6)

SDAB
(Type 2)

SDLA
(Type 3 Dual)

SDLT
(Type 4)

SDLE
(Type 3)

26 / 35 / 43.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

26 / 35 / 43.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

35 / 44 / 52.2

Station Noise Figure


Noise figure
(w / 1 dB for input EQ loss)

Typ. @ 54 MHz

dB

6.5

11.0

8.5

6.5

11.2

7.0

7.0

Typ. @ 550 MHz

dB

8.0

6.0

5.0

9.0

6.5

9.5

9.5

Typ. @ 1002 MHz

dB

6.5

7.0

5.5

7.5

6.5

7.5

7.5

Trunk / Feeder

Feeder

Feeder

Feeder

Feeder

Trunk

Feeder

Station Distortions (Worse Case)


Composite Triple Beat (CTB)

-dBc

79 / 71

68

76

72

70

79

79

Cross Modulation (XMOD)

-dBc

78 / 68

68

77

69

69

78

71

Composite Second Order (CSO-)

(Vc +0.75 & -1.25 MHz)

-dBc

72 / 71

74

77

77

69

72

69

Composite Second Order (CSO+)

(Vc +1.25 MHz )

-dBc

74 / 69

75

78

78

67

74

70

-dBc

76 / 69

66

74

70

68

76

77

Carrier-to-Intermodulation Noise (CIN)

Page 6 of 10

www.acicomms.com

REVERSE SPECTRUM:
REVERSE - CHANNEL LOADING - Typically 23 each, 1.5 MHZ wide QPSK channels.
UNITS

SPECIFICATION

MHZ

5 to 42

Normalized w / 0 dB slope

dB

0.5

+0.5 / -0 @ 40 MHz
(Temperature stabilized)

dB

18 or 23
(18, 21 or 23 for SDLE only)

Reverse - General

CONDITIONS

Station passband
Station flatness

Reverse - Station Gain


Gain
Gain control type

Plug-in pads

Gain control range


Gain control steps

dB

12.0

Pad value steps

dB

0.5

Cable equalizers

N/A

Plug-in EQs

dB

0 to 12.0

Equalizer value steps

dB

1.0

Average

dBmV

35.0

6 channel loading

-dBc

Reverse - Station Slope


Slope control type
Slope control range
Slope control steps

Reverse - Station Output Levels


@ Forward input port

REVERSE - STATION DISTORTIONS


Composite Second Order (CSO)
Composite Tripe Beat (CTB)

82.0
90.0

Cross Modulation (XMOD)

80.0

Reverse - Station Group Delay


Group delay

5 MHz

Group delay

7 MHz

Group delay

10 MHz

Group delay

35 MHz

Group delay

38.5 MHz

36
16
nSec /
1.5 MHz

4
10
25
SDAT
(Type 1)

SDAF
(Type 2 Tri)

SDBT
(Type 6)

SDAB
(Type 2)

SDLA
(Type 3 Dual)

SDLT
(Type 4)

SDLE
(Type 3)

dB

15.5

12.0

15.5

11.5

12.0

10.0

10.0

42.4

42.4

45.1

41.9

38.4

20.9

25.8

40.8

40.8

43.5

40.2

36.8

19.3

24.2

40.3

40.3

43.0

39.8

36.4

18.9

23.7

Configuration
Reverse - Noise Figure
Station noise figure (w / EQ)

Across the bandwidth

Power Requirements:
DSIM-A / SPAGC
Thermal

Includes reverse
(Worst case)

Manual

AC Voltage
Input ranges

VAC

40-90

Current Draw (with AGC)


@ 40 VAC

1.35

1.35

1.41

1.34

1.26

0.79

0.93

@ 50 VAC

1.18

1.18

1.23

1.17

1.10

0.69

0.81

@ 60 VAC

1.06

1.06

1.11

1.05

0.99

0.62

0.73

0.98

0.98

1.02

0.97

0.91

0.57

0.67

@ 80 VAC

0.90

0.90

0.94

0.89

0.84

0.52

0.62

@ 90 VAC

0.82

0.82

0.86

0.81

0.76

0.48

0.57

@ 70 VAC

Maximum

Environmental
o

Operating temperature

F (oC)

-40 to +140 (-40 to +60)

In, (cm)

6.75 X 14.25 X 9.00 (17.1 X 36.2 X 22.9)

lbs. (kg)

16.0 (7.26)

Physical
Dimensions
Weight

(H X W X D)

Page 7 of 10

www.acicomms.com

SDA & ALX 15 Amp Product Configuration Worksheet


Customer:
Created By:

Order Date:
October 5, 2012

ORDERING MATRIX
Position 1

10

11

12

13

14

15

PART NUMBER
STATION TYPE

A = ALX 1 Output Low Profile LE


B = SDAB 2 Output Feeder
C = SDLT 1 Output Trunk LE

D = SDLA 2 Output LE
F = SDAF 2 or 3 Output Feeder
J = SDBT 3 Equal Output Feeder

L = SDLE 1 Output LE
T = SDAT 3 Output Trunk

BANDWIDTH FREQUENCY

7
8

= 750 MHz Upper Frequency


= 870 MHz Upper Frequency

= 900 MHz Upper Frequency

= 1002 MHz Upper Frequency

STATION GAIN (Forward)- For 0.5 dB gain values, use the first two digits listed in the part number

3,4

Station Type
Amplifier Model

TYPE 1

TYPE 2

TYPE 3

SDAT

SDAB

SDLE

Frequency

750

870

900

Max gain w ith AGC/ Thermal


Max gain w /AGC bypass

28
33

31
34

31
34

Station Type

1002 1002
STD GaN
33
36
38
41

870

900

38
43

NA
NA

42
45

1002 1002
STD GaN
43
45
48
49

750

870

900

29
34

31
36

32
36

TYPE 2 TRI

TYPE 3 DUAL

TYPE 4

SDAF

SDLA

SDLT

Amplifier Model
Frequency

750

870

Max gain w ith AGC/ Thermal

37

40

NA

1002
STD
43

Max gain w /AGC bypass

42

43

NA

46

900

750

870

900

28

31

32

1002
STD
35.5

33

36

36

40.5

750

870

900

29
34

31
36

32
36

1002 1002
STD GaN
35.5 38.5
40.5 43.5

TYPE 6
SDBT

750

870

29

31

NA

1002
STD
33

34

36

NA

38

900

ALX
1002 1002
STD GaN
35.5 38.5
40.5 43.5

750

870

NA

40

NA

1002
STD
41

NA

43

NA

44

900

CONTROL TYPE

D = Digital Station Intelligence Manger (DSIM)


T = Thermal Bode

P = Single Channel Pilot (Analog only)


M = Manual (AGC Bypass)

C = Composite AGC (750 MHz only)

CONTROL FREQUENCY

A = Channel 52
B = Channel 54
C = Channel 58
D = Channel 59
E = Channel 60
F = Channel 61
G = Channel 62
H = Channel 70
7

750

TYPE 3

391.25 MHz
403.25 MHz
427.25 MHz
433.25 MHz
439.25 MHz
445.25 MHz
451.25 MHz
499.25 MHz

SC or SP AGC
SCAGC only
SPAGC only
SCAGC only
SC or SP AGC
SPAGC only
SC or SP AGC
SC or SP AGC

CURRENT PASSING CAPACITY 15A (Continuous on all ports)


550
8.5
7.6
8.9
9.0
7.9
7.3

STATION SLOPE

J = Channel 72
511.25 MHz SPAGC only
M = Channel 70HRC 498.025 MHz SPAGC only
N = Channel 58HRC 426.021 MHz SPAGC only
0 = Thermal Bode
1 = AGC Bypass
2 = DSIM-A Single Pilot AGC (Analog or Digital pilot) - Pilot channel loaded during setup

A=
C=
D=
E=
F=
T=

650
10.2
9.1
10.7
10.8
9.4
8.8

750
11.9
10.7
12.5
12.6
11.0
10.3

870
14.0
12.5
14.7
14.8
12.9
12.0

900
14.5
NA
NA
15.3
13.4
12.5

1002
NA
NA
NA
17.2
15.0
14.0

HOUSING OPTIONS

0
1
E
F

= No housing or pow er pack


= Module upgrade kit w ith pow er supply and seizure screw s
= SDA - Standard w ith TP
= SDA - Chromate w ith TP

B
G
H
K

= SDA - Chromate w ithout TP


= ALX - Standard low profile line extender w ith TP
= ALX - Chromate low profile line extender w ith TP
= ALX - Chromate low profile line extender w ithout TP

DIPLEX FREQUENCY SPLIT

10

=42 / 53

=55 / 70 (870 MHz Only)

=65 / 85 (870 MHz Only)

=85 / 105 (SDA 1G only)

STATION GAIN (Reverse)

11

0 = None
1 = Passive

4 = 18 dB min (SDA: T, B, F, LA, BT)


H = 18 dB min (SDLE, LT & ALX only)
R = 21 dB min (SDLE, LT & ALX only)

T = 23 dB min (SDA: T, B, F, BT, LA, LE ) - SDA 1G Only

SURGE PROTECTION

12

13,14

15

A
C

= Plug-in sidactor (Included in SDA 1002 MHz and all of the ALX amplifiers & recommended for SDA 750, 870 & 900 MHz units)
= Triac (Included in all SDA pow er supplies), The sidactor is recommend to increase surge protection level of the SDA units

TEST SPECS (Determined by ACI engineering)

SPECIAL/CUSTOMER: LABELS, FUNCTIONS, (Determined by Product Management)


0, 1 = No special instructions
T or R = Trunk line extender for ALX
N = GaN Forw ard Hybrids (SDA 1G only)

2 = Customer P/N in description


M = Status monitoring pick-offs installed

3 = SDAF w /3 dB splitter installed


C = Module cover w ith thumb screw s (SDA 1G only)

Generic Order Form: Not all configurations are available

Page 8 of 10

www.acicomms.com

Accessory Ordering Information:


The SDA ordering matrix provides the part number information to order the configured stations. This page
contains the ordering information for the required accessories that will be needed to make the stations
functional in the field or the optional accessories that can be ordered separately.

Required Accessories
Part Numbers
(Where XX.X = dB value)

Description
JXP style attenuator pads
1 Required for forward input
1 Required for reverse output (if active)

JXP1.38-XX.X (0 to 20 dB in 0.5 dB steps)

Forward equalizers
1 Required forward input

EQDA1G/XX (1.0 to 18.0 dB in 1.0 dB steps)


(20.0 to 30.0 dB in 2.0 dB steps)
CEQ1G/XX (1.0 to 12.0 dB in 1.0 dB steps)

Reverse equalizers
1 Required reverse output (if active)

REQDA42/XX (0 to 12.0 dB in 1.0 dB steps)


REQDA85/XX (1 to 12.0 dB in 1.0 dB steps)

Optional Accessories
Description

Part Numbers

Digital Station Intelligence Manager Single Pilot AGC Module (Analog or Digital)

DSIM-A-MDL-01

Digital Station Intelligence Manager -Controller

DSCT-xxx-yyy
xxx = Pilot Channel Number
yyy = Channel Type
IRC = Analog IRC Spacing
DIG = Digital / QAM

Digital Station Intelligence Manager - Cable Assembly


For Computer Interface

240327-01

Single Pilot AGC (Analog Only)


(See SDA ordering matrix for available pilot channels)

SPAGC1G-XX
(XX = Pilot Channel Number)

Thermal Bode AGC

T-BODE-1G

Manual AGC (Bypass plug-in)

AGC-BYPASS-1G

Reverse equalizers with thermal compensation

REQTH42/XX (1 to 12.0 dB in 1.0 dB steps)

Reverse JXP style pads with thermal compensation

THJXP138-XX.X (1.0 to 20 dB in 1.0 dB steps)

Reverse Rejection Filter 14 MHz

RPRFLTR-14

Reverse Rejection Filter 8 MHz

RPRFLTR-8

DC/SP3 Plug-in - SDAF only

SDA1G-SPLTR3.5
SDA1G-DC7
SDA1G-DC12

Test Probe (5.5 Long)

100685-01

Test Probe (1.57 / 4 cm Long)

TP-7504

Thru-housing Test Cable. Allows reading of internal test points


with the housing closed.

240310

Page 9 of 10

www.acicomms.com

Optional Accessories (Continued)


Description

Part Numbers

Test Adapter for Test Probe to Seizure Screw (RF Connector)

100677

AC Power Director

100818-01

Alignment Tool 5-3/16" (Tweaker Stick)

130315

EQ Puller Tool

130311

Power Supply (40-90 VAC) Version 3

SDA90VSP-V3

Replacement Housing (Standard)

HSG03/00

Replacement Housing (Chromate)

HSG04/00

Metal 5/8" Port Housing Caps

H5/8PLUG

Housing Port Dielectric Insert

030765-01

Seizure Screw / RF Connector 15A

100633-01

ACI Communications, Inc. reserves the right to Page


discontinue
10 of the
10
manufacture or change specifications without prior notice on any parts
illustrated in this data sheet.

Rev Y 10-10-2012 ACI Communications,


Inc.
www.acicomms.com
Printed in U.S.A.

You might also like