HCPT - HUAWEI

1. Antenna Fastness
Key Points

Details Description

The antenna must be


installed in the right
height and position and
polarization

The fixation of antenna


and pole are reliable

RTN 600 MW Installation Standard

Each screw should be fastness very well

HCPT - HUAWEI

For the more than 1.2m antenna, the side strut must be installed and fixed
position is correct.

Antenna identifier
(standard labeling)

Labeling Format:

Label template :





RTN 600 MW Installation Standard

ANTENNA TO XXX (FE ID)


FAR END NAME

Font : Black
Background : White
Material : Print Label

HCPT - HUAWEI

2. ODU Fastness
Key Points
The ODU's and hybrid
coupler's appearance are
properly

Details Description
Tighten all screw / bolt from ODU to hybrid
ODU Fixing

IF connector from ODU should be waterproofed properly

Waterproofing

The IF connector of ODU


should be waterproofed
and face downward

Waterproofing

RTN 600 MW Installation Standard

HCPT - HUAWEI

The ODU grounding


cable should be shortest
length as possible and
attached to bus bar

ODU Grounding

Grounding connection
to bus bar

RTN 600 MW Installation Standard

HCPT - HUAWEI

ODU Identifier (ODU


labeling)

Labeling Format:

Label template :






ODU1 TO XXX (FE ID)


FAR END NAME

For 1+1, mark ODU1 for main ODU and ODU2 for stand by ODU
Font : Black
Background : White
Material : Print Label

3. IF Distribution
Key Points
In general, the IF cable
should be grounded to a
minimum of one point

Details Description
IF grounding kit installed between concurrence HCT and VCT
Tower

Recommended point to
install IF grounding kit

RTN 600 MW Installation Standard

HCPT - HUAWEI

2 end are tidy with cable tie

Tidy up with cable tie

IF grounding kit should connect to lower VCT bus bar.

Grounding kit
connect to bus bar

Leave enough slack when


connecting cables to the
ODU to facilitate future
maintenance

IF redundant no more than 2 meters

IF redundant no more
than 2m

RTN 600 MW Installation Standard

HCPT - HUAWEI

IF cable must be up tilted


or have Waterproof curve
in the entrance of
porthole

Right position for hole IF cable route

Porthole connection should be waterproofed

Cable Installation and end


to end labeling

RTN 600 MW Installation Standard

Proper installation for IF


cable and separation with
GND cable

HCPT - HUAWEI

IF cable labeling /
identifier

IF cable should have identifier / labeling on top near connector of


ODU and IDU
Outdoor IF Labeling

Outdoor labeling:

Labeling Format:

Label template :






RTN 600 MW Installation Standard

Indoor IF Labeling

Indoor labeling:

IF 1 TO XXX (FE ID)


FAR END NAME

For 1+1, use mark IF1 for main IF and IF2 for stand by IF
Font : Black
Background : White
Material : Print Label, Label flag, cable ties, IF cable label

HCPT - HUAWEI

4. Indoor Equipment Fastness


Key Points
The installation
position of IDU
accords to the
engineering design
document.

Details Description
Outdoor Installation and IDU placement (on BTS 3012AE)

Outdoor Installation and IDU placement (on BTS 3900A)

Indoor Installation and IDU placement on 19 rack

RTN 600 MW Installation Standard

10

HCPT - HUAWEI

IDU and DCPDB


labeling standard

Standard labeling and labeling format

IF Board Labeling
Labeling Format:

Label template :
TO : FE ID , FE NAME
TX. xxxx MHz, RX. xxxx MHz






For 1+1, use mark IF1 for main IF and IF2 for stand by IF
Font : Black
Background : White
Material : Print Label,

Power Cable Labeling


Labeling Format:

Label template :
TO : POWER CABLE





Font : Black
Background : White
Material : Print Label, Flag label tie

Tributary Cable Labeling


Labeling Format:

Label template :
TO : DDF






Font : Black
Background : White
Material : Print Label, Flag label tie

Labeling on rectifier power cable


Labeling Format:

Label template :
TO : FAR END ID





RTN 600 MW Installation Standard

Font : Black
Background : White
Material : Print Label, Flag label tie

11

HCPT - HUAWEI

Labeling on DCPDB
Labeling Format:

Label template :
TO : FAR END ID





DDF Labeling
Standard

Font : Black
Background : White
Material : Print Label

Standard labeling for outdoor DDF (sample)

Standard labeling for Indoor DDF (sample)

RTN 600 MW Installation Standard

12

HCPT - HUAWEI

5. Cable distribution and routing


Key Points
Cable distribution and
cable routing

Details Description
Cable routing standard for outdoor BTS.

Cable routing standard for indoor BTS (1).

RTN 600 MW Installation Standard

13

HCPT - HUAWEI

Cable routing standard for indoor BTS (2).

RTN 600 MW Installation Standard

14

HCPT - HUAWEI