You are on page 1of 20

COMMErCIal HEaTIng

Free five year parts and


labour warranty
EC motor technology
Manufactured in the UK
ISO9001 accredited

Think Fan Convector, Think Smiths

Contents

Summary of product range

p3

1. Products with EC motors

p 4-5

2. Products with aC Motors

p 6-13

3. natural Convectors (perimeter heating) p 14


4. Electric Heaters

p 15-18

If you require energy efficiency and


versatility in your heating, the Smiths range
of fan convectors is the ideal solution.
Why use fan convectors?
Fan convector technology has been widely available for many years and provides an
energy efficient alternative to radiators as a source of heat. As an example, a SAP*
calculation, using the combination of air source heat pump and fan convector in a new
build property, should show at least a 12% reduction in running costs and is close to
the efficiencies achieved by installing under floor heating. Furthermore fan convectors
only use 5% of the water content of an equivalent output radiator, ensuring they are
more responsive to ever-changing daily weather patterns, as well as peoples personal
heat preferences.
A fan convectors ability to deliver heat effectively and efficiently at all system temperatures,
while using standard system design, makes them ideal for both existing and new
buildings. They are compatible with every type of heat generator, from boilers to
renewable technology such as ground or air source heat pumps. Unlike radiators, which
are hot to touch, fan convectors have very low surface temperatures, making them
completely safe and therefore ideal for children and the elderly.
*SAP: Standard Assessment Procedure.

Why choose Smiths?


Since 1991, Smiths has manufactured an extensive portfolio of domestic and light
commercial products in our manufacturing facility in Essex, UK. Our commercial
portfolio includes the Caspian commercial fan convector range, Skyline and the
Ecovector range of fan convector. We work with a broad range of commercial installers
and specifiers on a wide number of projects that include schools and nurseries, churches
and other places of worship, libraries, care and nursing homes, office space and other
commercial projects. Smiths has significant shares of both the North American and
European markets. Every Smiths product carries a five year parts and labour guarantee.

www.smiths-env.com/commercial

Summary of product range

Caspian Universal
EC motors p4-5

Caspian High
AC motors p6-7

Caspian low
AC motors p6-7

Skyline
AC motors p8

One heating solution for a variety of


applications, suitable for high, low or
ceiling-mounted installation.
Incorporating EC motor technology, the
Universal delivers heat quickly,
efficiently and effectively. Heat outputs
up to 14.5kW (49400 Btu/h).

Designed for unobtrusive fixing at high


level, Caspians rapid response heating
is ideal for heating the large areas of
schools, churches, care homes, libraries,
offices, and hospitals. Heat outputs up
to 14.4kW (49200 Btu/h).

A floor or wall-mounted fan convector


developed for a diversity of applications
in commercial installations. Available in
a range of eight models and a low
surface temperature casing for complete
safety. Heat outputs up to 14.4kW
(49200 Btu/h).

The ceiling-mounted Skyline provides


the perfect solution to heating larger
commercial spaces. Units install simply
into a standard 600mm x 600mm
ceiling tile space. There is also an allelectric model available. Heat outputs
up to 5.5kW (18800 Btu/h).

Ecovector low
AC motors p9

Ecovector High/Sterling
AC motors p10-11

EcoPowerad
AC motors p12

Ecovector Vertical
AC motors p13

Combining stylish good looks with


energy efficiency, Ecovector Low
includes built-in thermostatic control.
Heat outputs up to 3.5kW (12100
Btu/h).

Designed for unobtrusive fixing at high


level and ideal for retail units, offices
and nurseries. Both hydronic and
electric versions available plus a low
voltage model for bathrooms. Heat
outputs up to 4.0 kW (13500 Btu/h).

The fan convector of the future


energy efficient, responsive and capable
of installation within most wet central
heating systems driven by either boilers
or low temperature renewable
technology. Heat outputs up to 3.9kW
(13200 Btu/h).

Designed for installation in narrow


spaces like hallways and reception
areas, this vertical low-level wallmounted fan convector includes
wireless thermostatic control. Heat
output up to 2.6kW (8800 Btu/h).

Sureline
Natural convectors p14

Skyline
Electric heaters p15

Sterling
Electric heaters p16

Sygnet
Electric heaters p17

A natural convector fitted at skirting


level the ideal form of perimeter
heating, providing gentle low-level
warmth anywhere from waiting rooms,
workshops, canteens, hallways and
conservatories. Heat outputs up to
820kW (2520 Btu/h) per metre.

Like its hydronic sibling, this is designed


for unobtrusive fixing at high level and
is ideal for retail units, showrooms and
nurseries. Allows maximum use of wall
space with a safe, high-level heat source.
Heat outputs up to 4.0kW. Hydronic
versions available.

Designed for unobtrusive fixing at high


level and ideal for retail units, offices
and nurseries. Heat outputs up to
4.0kW. Hydronic versions available.

Versatile and economic, a low-level fan


assisted electric convector that can be
surface or flush mounted; ideal for
those areas, where space may be at a
premium. Heat outputs up to 2.0kW.

Space Saver Electric


Electric heaters p18
An electric version of our popular
plinth heater that fits neatly into the
plinth of a kitchen unit, replacing a
radiator and providing more work
surface and storage for end users.

www.smiths-env.com/commercial

1. Products with EC motors

Caspian Universal
One heating solution for a variety of applications - suitable for high, low or ceilingmounted installation, you can even turn it upside down.
Caspian low surface temperature fan convectors have been specially developed for a wide
range of applications in larger spaces and commercial environments. With the ability to
rapidly heat large areas at low cost, Caspian Universal fan convectors are both practical
and energy efficient. Supplied as standard in white but can be supplied in any colour.
Incorporating the latest EC motor technology which can result in running cost savings as
high as 80% and with variable speed control as standard, the Caspian Universal delivers
heat quickly, efficiently and effectively.
The Caspian Universal, in line with all Smiths fan convector is compatible with most types
of wet central heating systems and functions equally efficiently, whether connected to a
conventional boiler or renewable technology, such as biomass boilers or ground or air
source heat pumps.

Caspian Universal mounted low


Model

Caspian Universal mounted high

Heat Output at 80

Heat Output at 75

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Caspian UV 120

6.7 (22700)

10.6 (36000)

Caspian UV 90

5.2 (17700)

7.8 (26500)

Caspian UV 60

3.2 (10900)

4.5 (15500)

Model

Heat Output at 70

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

14.5 (49400)

6.1 (20937)

9.6 (32968)

13.2 (45000)

5.6 (19100)

8.7 (29800)

11.8 (40400)

10.3 (35200)

4.8 (16300)

7.2 (24600)

9.6 (32800)

4.4 (15000)

6.7 (22700)

8.9 (30400)

5.9 (20000)

2.9 (9900)

4.1 (14000)

5.3 (18100)

2.6 (8800)

3.7 (12500)

4.8 (16200)

Heat Output at 65

Heat Output at 60

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Caspian UV 120

4.9 (16600)

7.7 (26400)

Caspian UV 90

3.9 (13500)

6.0 (20400)

Caspian UV 60

2.3 (7800)

3.2 (11100)

Model

Caspian Universal ceiling-mounted

Heat Output at 55

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

10.6 (36200)

4.1 (14100)

6.7 (23000)

9.4 (32000)

3.4 (11600)

5.8 (19700)

8.1 (27700)

8.0 (27300)

3.5 (11900)

5.3 (18000)

7.1 (24200)

3.0 (10400)

4.6 (15800)

6.2 (21100)

4.2 (14300)

2.0 (6800)

2.8 (9600)

3.6 (12400)

1.7 (5800)

1.9 (8200)

2.0 (10600)

Heat Output at 50

Heat Output at 45

Heat Output at 40

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Low
(KW/BTU)

Medium
(KW/BTU)

High
(KW/BTU)

Caspian UV 120

2.6 (9000)

4.8 (16300)

6.9 (23500)

2.0 (6700)

3.7 (12600)

5.4 (18400)

Caspian UV 90

2.6 (8800)

3.9 (13400)

5.3 (18000)

2.0 (7000)

3.1 (10500)

4.1 (14000)

1.3 (4400)

2.6 (8900)

3.9 (13400)

1.5 (5100)

2.2 (7500)

Caspian UV 60

1.4 (4800)

2.0 (6800)

2.5 (8700)

1.1 (3800)

1.5 (5100)

1.9 (6300)

0.8 (2700)

2.9 (10000)

1.0 (3400)

1.2 (4000)

Heat outputs tested in accordance with BS4856 using mean water temperature, 18C entering air temperature, 10C temperature drop and a flow rate of 340 litres/h.

www.smiths-env.com/commercial

Model

Total Power Consumption


Flow & Return
Connections

Mains
Cable

Transformer

Flexible
Hoses

Isolation
Valves

Fused
Spur

Low
(Watts)

Medium
(Watts)

High
(Watts)

Water Capacity
(Litres)

Caspian UV 120

22mm

n/a

n/a

n/a

n/a

3A

13

62

110

2.08

Caspian UV 90

22mm

n/a

n/a

n/a

n/a

3A

15

43

70

1.50

Caspian UV 60

22mm

n/a

n/a

n/a

n/a

3A

24

40

0.92

Correction factors
Model

Mean Water Temperature C

Sound Levels
High
(dBA)

Medium
(dBA)

Low
(dBA)

Casting
Colour

Fan
Only

Caspian UV 120

58

46

35

White

n/a

Caspian UV 90

53

42

34

White

n/a

Caspian UV 60

50

42

33

White

n/a

Plinth

15

1.10

21

0.93
Temperature Drop C

Measured at 3m in front of floor mounted model.

Wall mounted
controller

80 to 40

EATC

Factor

Adjustable low
temperature
cut-out

20

15

10

0.89

0.95

1.00

1.04

Wall mounted room


thermostat

Caspian Universal
Finish

Caspian Universal

Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010


Available to special order in any colour

660

Available with anti-microbial or anti-bacterial paint

274

66

Installation
Suitable for two-pipe central heating systems

Pipe Centres 176

245

Maximum installation height for high or ceiling mounting - 4m to


underside
Pipework access holes on the rear and underside

Electrical supply
in this side

Key operated front access panels


Bleed valve accessible on removal of front casing
Unit must be earthed

Commissioning
Check water is hot enough to activate the low temperature cut-out
thermostat
Controls
Variable heat output controller (mounted within the product)

All dimensions in mm

accessories

Model
60
90
120

a
595
895
1195

Plinth (150mm) to suit each model, available in black or white


Adjustable low temperature cut-out (30C to 90C)
Wall mounted controller
Wall mounted room thermostat

www.smiths-env.com/commercial

2. Products with aC motors

Caspian High & Low


Caspian low surface temperature fan convectors have been specially developed for a
wide range of applications in larger spaces and commercial environments. With the ability
to rapidly heat large areas at low cost, Caspian commercial fan convectors are both
practical and energy efficient. Fully compatible with renewable energy technology, such
as ground and air source heat pumps, Caspian can also enhance your environmental
credentials. Supplied as standard in white but can be supplied in any colour.

High Level

Low Level

Model
Low Level

High Level

Low
kW (Btu/h)

Heat Output at 80C


Medium
kW (Btu/h)

High
kW (Btu/h)

Low
kW (Btu/h)

Heat Output at 75C


Medium
kW (Btu/h)

High
kW (Btu/h)

Hydronic
Caspian LL 120/12

Caspian HL 120/12

11.4 (39000)

13.4 (45800)

14.4 (49200)

10.4 (35500)

12.2 (41600)

13.1 (44700)

Caspian LL 120/11

Caspian HL 120/11

10.5 (35700)

12.5 (42800)

13.4 (45800)

9.5 (32400)

11.4 (38900)

12.2 (41600)

Caspian LL 120/10

Caspian HL 120/10

9.5 (32300)

11.4 (39000)

12.5 (42800)

8.6 (29300)

10.4 (35500)

11.4 (38900)

Caspian LL 90/07

Caspian HL 90/07

6.8 (23300)

7.7 (26300)

8.6 (29300)

6.2 (21200

7.0 (23900)

7.8 (26600)

Caspian LL 90/06

Caspian HL 90/06

6.2 (21100)

6.8 (23300)

7.4 (25100)

5.6 (19100)

6.2 (21200)

6.7 (22900

Caspian LL 60/04

Caspian HL 60/04

4.0 (13500)

4.5 (15400)

5.1 (17300)

3.6 (12300)

4.1 (14000)

4.6 (15700)

Caspian LL 60/03

Caspian HL 60/03

3.2 (10900)

3.5 (12000)

3.7 (12800)

2.9 (9900)

3.2 (11000)

3.4 (11600)

High Level

Low
kW (Btu/h)

Heat Output at 70C


Medium
kW (Btu/h)

High
kW (Btu/h)

Low
kW (Btu/h)

Heat Output at 65C


Medium
kW (Btu/h)

High
kW (Btu/h)

Caspian LL 120/12

Caspian HL 120/12

9.3 (31600)

10.9 (37000)

11.7 (39800)

8.2 (28000)

9.6 (32900)

10.3 (35300)

Caspian LL 120/11

Caspian HL 120/11

8.5 (28800)

10.1 (34600)

10.9 (37000)

7.5 (25600)

9.0 (30700)

9.6 (32900)

Caspian LL 120/10

Caspian HL 120/10

7.7 (26100)

9.3 (31600)

10.1 (34600)

6.8 (23200)

8.2 (28000)

9.0 (30700)

Caspian LL 90/07

Caspian HL 90/07

5.5 (18800)

6.2 (21300)

6.9 (23700)

4.9 (16700)

5.5 (18900)

6.2 (21000)

Caspian LL 90/06

Caspian HL 90/06

5.0 (17000)

5.5 (18800)

6.0 (20300)

4.4 (15100)

4.9 (16700)

5.3 (18100)

Caspian LL 60/04

Caspian HL 60/04

3.2 (10900)

3.6 (12500)

4.1 (14000)

2.8 (9700)

3.2 (11000)

3.6 (12400)

Caspian LL 60/03

Caspian HL 60/03

2.6 (8800)

2.8 (9700)

3.0 (10300)

2.3 (7800)

2.5 (8600)

2.7 (9200)

High Level

Low
kW (Btu/h)

Heat Output at 60C


Medium
kW (Btu/h)

High
kW (Btu/h)

Low
kW (Btu/h)

Heat Output at 55C


Medium
kW (Btu/h)

High
kW (Btu/h)

Caspian LL 120/12

Caspian HL 120/12

7.2 (24500)

8.4 (28700)

9.0 (30800)

6.2 (21300)

7.3 (25000)

7.9 (26800)

Caspian LL 120/11

Caspian HL 120/11

6.6 (22400)

7.9 (26900)

8.4 (28700)

5.7 (19500)

6.8 (23300)

7.3 (25000)

Caspian LL 120/10

Caspian HL 120/10

5.9 (20200)

7.2 (24500)

7.9 (26800)

5.2 (17600)

6.2 (21300)

6.8 (23400)

Caspian LL 90/07

Caspian HL 90/07

4.3 (14600)

4.8 (16500)

5.4 (18400)

3.7 (12700)

4.2 (14300)

4.7 (16000)

Caspian LL 90/06

Caspian HL 90/06

3.9 (13200)

4.3 (14600)

4.6 (15800)

3.4 (11500)

3.7 (12700)

4.0 (13700)

Caspian LL 60/04

Caspian HL 60/04

2.5 (8500)

2.8 (9700)

3.2 (10800)

2.2 (7300)

2.5 (8400)

2.8 (9400)

Caspian LL 60/03

Caspian HL 60/03

2.0 (6900)

2.2 (7500)

2.3 (8000)

1.7 (6000)

1.9 (6600)

2.0 (7000)

High Level

Low
kW (Btu/h)

Heat Output at 50C


Medium
kW (Btu/h)

High
kW (Btu/h)

Low
kW (Btu/h)

Heat Output at 45C


Medium
kW (Btu/h)

High
kW (Btu/h)

Caspian LL 120/12

Caspian HL 120/12

5.3 (18100)

6.2 (21200)

6.7 (22800)

4.2 (14200)

4.9 (16700)

5.2 (17900)

Caspian LL 120/11

Caspian HL 120/11

4.8 (16500)

5.8 (19800)

6.2 (21200)

3.8 (13000)

4.6 (15600)

4.9 (16600)

Caspian LL 120/10

Caspian HL 120/10

4.4 (15000)

5.3 (18100)

5.8 (19800)

3.4 (11700)

4.2 (14200)

4.6 (15600)

Caspian LL 90/07

Caspian HL 90/07

3.2 (10800)

3.6 (12200)

4.0 (13600)

2.5 (8500)

2.8 (9600)

3.1 (10600)

Caspian LL 90/06

Caspian HL 90/06

2.9 (9700)

3.2 (10800)

3.4 (11700)

2.2 (7600)

2.5 (8500)

2.7 (9100)

Caspian LL 60/04

Caspian HL 60/04

1.8 (6250)

2.1 (7100)

2.3 (8000)

1.4 (4900)

1.6 (5600)

1.8 (6300)

Caspian LL 60/03

Caspian HL 60/03

1.5 (5100)

1.6 (5600)

1.7 (5900)

1.2 (3950)

1.3 (4350)

1.4 4650)

Model
Low Level
Hydronic

Model
Low Level
Hydronic

Model
Low Level
Hydronic

Heat outputs tested in accordance with BS4856 using mean water temperature, 18C entering air temperature, 10C temperature drop and a flow rate of 340 litres/h.

www.smiths-env.com/commercial

Model
High Level

Low
kW (Btu/h)

Heat Output at 40C


Medium
kW (Btu/h)

High
kW (Btu/h)

Caspian LL 120/12

Caspian HL 120/12

3.2 (11000)

3.8 (12900)

4.1 (13900)

Caspian LL 120/11

Caspian HL 120/11

2.9 (10000)

3.5 (12100)

3.8 (12900)

Caspian LL 120/10

Caspian HL 120/10

2.7 (9100)

3.2 (11000)

3.5 (12100)

Caspian LL 90/07

Caspian HL 90/07

1.9 (6600)

2.2 (7400)

2.4 (8300)

Caspian LL 90/06

Caspian HL 90/06

1.7 (5900)

1.9 (6600)

2.1 (7100)

Caspian LL 60/04

Caspian HL 60/04

1.1 (3800)

1.3 (4350)

1.4 (4900)

Caspian LL 60/03

Caspian HL 60/03

0.9 (3050)

1.0 (3400)

1.1 (3600)

Low Level
Hydronic

Heat outputs tested in accordance with BS4856 using mean water temperature, 18C entering air temperature, 10C temperature drop and a flow rate of 340 litres/h.
Correction factors
Mean Water Temperature C
EATC

Model

80 to 40

15

1.10

21

0.93

Low Level

High Level

Sound Levels
Medium
Low
(dBA)
(dBA)

Casing
Colour

Fan-Only

Hydronic

Temperature Drop C
Factor

High
(dBA)

20

15

10

0.89

0.95

1.00

1.04

Caspian LL 120/12

Caspian HL 120/12

48

46

42

White

n/a

Caspian LL 120/11

Caspian HL 120/11

46

44

39

White

n/a

Caspian LL 120/10

Caspian HL 120/10

44

42

37

White

n/a

Caspian LL 90/07

Caspian HL 90/07

42

40

37

White

n/a

Caspian LL 90/06

Caspian HL 90/06

43

40

37

White

n/a

Caspian LL 60/04

Caspian HL 60/04

38

35

32

White

n/a

Caspian LL 60/03

Caspian HL 60/03

40

37

34

White

n/a

Sound levels measured at 1.5m.


Model
Low Level

High Level

Flow & Return


Connections

Mains
Cable

Flexible
Hoses

Transformer

Isolating
Valves

Total Power Consumption


Low
Medium
High
(Watts)
(Watts)
(Watts)

Fused
Spur

Water Capacity
(Litres)

Hydronic
Caspian LL 120/12

Caspian HL 120/12

22mm

n/a

n/a

n/a

n/a

3A

99

135

151

2.08

Caspian LL 120/11

Caspian HL120/11

22mm

n/a

n/a

n/a

n/a

3A

60

114

135

2.08

Caspian LL 120/10

Caspian HL 120/10

22mm

n/a

n/a

n/a

n/a

3A

53

99

114

2.08

Caspian LL 90/07

Caspian HL 90/07

22mm

n/a

n/a

n/a

n/a

3A

53

60

98

1.50

Caspian LL 90/06

Caspian HL 90/06

22mm

n/a

n/a

n/a

n/a

3A

53

60

98

0.72

Caspian LL 60/04

Caspian HL 60/04

22mm

n/a

n/a

n/a

n/a

3A

29

36

51

0.92

Caspian LL 60/03

Caspian HL 60/03

22mm

n/a

n/a

n/a

n/a

3A

29

36

51

0.56

Thermostat and auto


speed control

Adjustable low
temperature
cut-out

Wall mounted room


thermostat

Tamperproof control
panel
Caspian low level

Caspian High & low


Finish
Casing: zinc-coated steel 1.2mm
Polyester powder-coated: white RAL 9010
Available to special order in any colour
Available with anti-microbial paint
Installation
Suitable for two-pipe central heating systems
Mounting brackets supplied for both models (low level models can sit on the
floor)
Maximum installation height for high level mounted model - 4m to
underside
Pipework access holes on the rear and underside (Low) and top (High)
Key operated front access panels
Bleed valve accessible on removal of front casing
Tamperproof control panel (low level models only)
Unit must be earthed
Commissioning
Check water is hot enough to activate the low temperature cut-out thermostat
Controls
Rocker switch - low/medium/high heat output
Illuminated rocker switch - on/off
Facility to connect room thermostat
Low temperature cut-out thermostat set to energise fan at approximately 35C
accessories
Wall mounted room thermostat
Adjustable low temperature cut-out (30C to 90C)
Thermostat (T1) & auto speed control (T2) Low only

Caspian High level

Pipe Centres 176

245

66
250
530

Electrical supply in this side


All dimensions in mm

Model
60
90
120

a
595
895
1195

www.smiths-env.com/commercial

2. Products with aC motors

Skyline

The Skyline fits neatly into existing ceiling space - replacing a 600mm x 600mm ceiling
tile and because it is ceiling mounted, it saves valuable wall space - particularly important
in retail units. It is unobtrusive and effective. Supplied as standard in white but casing can
be supplied in any colour.

Heat Output at 80C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 75C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 70C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 65C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Skyline CT18

3.5 (11900)

3.1 (10700)

2.8 (9600)

2.5 (8700)

Model

Heat Output at 60C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 55C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 50C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 45C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Skyline CT18

2.3 (7900)

2.1 (7000)

1.8 (6000)

1.5 (5100)

Model

Heat Output at 40C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Model
Hydronic

5.5 (18800)

5.0 (16900)

4.4 (15000)

3.9 (13200)

Hydronic
3.3 (11400)

2.6 (8900)

Sound Levels
Normal
Boost
(dBA)
(dBA)

Model

Hydronic

2.2 (7600)

Casing Colour

Fan-Only

White

Hydronic

Skyline CT18

1.2 (4100)

1.8 (6300)

Heat outputs tested in accordance with BS4856 using entering water temperature.
Fan-only option operational only when central heating system is switched off.

Model

3.0 (10100)

Flow and Return


Connections

Main
Cable

22mm

1.5m

Skyline CT18

44

55

Sound levels measured at 1.5m.

Transformer

Flexible
Hoses

Isolating
Valves

Fused
Spur

n/a

n/a

n/a

3A

Power Consumption
Normal
Boost
(Watts)
(Watts)

Water Capacity
(Litres)

Hydronic
Skyline CT18

50

Skyline CT18

Skyline CT18

0.9

Pipe Centres
22

28

Finish
Outer casing 0.7mm zinc-coated steel. Polyester powder-coated
Paint specification: textured white, BS 4800 00A01 18% gloss

70

22mm
Flow and Return Pipes

90

Installation

90

Maximum installation height 3.2m (10'6") to underside

100

Installed to 180mm - penetration depth in recess (excluding fittings)


Four air inlet options: room only, void only, room and void, fresh air
(spigot required)

Outlet panel fits over


ceiling tile frame

600mm side clearance required

Air in void or room


damper at both ends

Fixing brackets (4) supplied for connection to 6mm threaded rods or chains
(rods and chains - not supplied)

Heat exchanger
drain off valve

Blanking plates (2) supplied for air circulation options

600

Unit must be earthed

542

Supplied with remote operating switch


516
centres

Suitable for two-pipe central heating systems only


Commissioning

498
centres

45
centres

Check water temperature is hot enough to activate low temperature


cut-out (LTC). The inclusion of an automatic air vent at the highest point is
recommended to avoid possible air locks
Controls
Two rocker fan switches - normal/off/boost, fan-heating/fan-only.
Low temperature cut-out thermostat set to energise fan at approximately 35C

280

555 600

Fixing points

accessories
Wall mounted room thermostat
Fresh air inlet spigot to suit 100mm flexible hose

www.smiths-env.com/commercial

2. Products with aC motors

Ecovector Low

Ecovector Low Level fan convectors provide warmth from the floor upwards and are
more energy efficient and effective than radiators. The Ecovector can heat up a room
more quickly than radiators, thereby reducing the amount of time your boiler or heat
pump is running - making it extremely efficient and cost effective. Ideal for new and
existing developments, due to ease of installation, the Ecovector is available in a range of
models to suit varying room sizes and heat output requirements. Supplied as standard in
white but casing can be supplied in any colour.

Heat Output at 80C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Model

Heat Output at 75C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 70C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 65C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Hydronic
Ecovector LL 2800

2.8 (9700)

3.5 (12100)

2.6 (9000)

3.2 (11050)

2.3 (8000)

2.9 (10000)

2.0 (6800)

2.6 (9000)

Ecovector LL 2000

2.0 (6900)

2.6 (8900)

1.9 (6400)

2.4 (8200)

1.6 (5500)

2.2 (7600)

1.5 (5000)

1.9 (6600)

Ecovector LL 1200

1.2 (4000)

1.6 (5400)

1.1 (3700)

1.4 (4800)

1.0 (3350)

1.3 (4300)

0.9 (3000)

1.1 (3900)

Model

Heat Output at 60C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 55C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 50C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 45C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Ecovector LL 2800

1.9 (6400)

2.4 (8100)

1.5 (5200)

2.1 (7200)

1.3 (4500)

1.8 (6100)

1.2 (4000)

1.5 (5200)

Ecovector LL 2000

1.3 (4550)

1.7 (5900)

1.2 (4050)

1.6 (5300)

1.0 (3500)

1.3 (4400)

0.9 (3050)

1.1 (3700)

Ecovector LL 1200

0.8 (2600)

1.0 (3450)

0.7 (2250)

0.8 (2900)

0.6 (1900)

0.7 (2500)

0.5 (1600)

0.6 (2050)

Model

Heat Output at 40C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Hydronic

Sound Levels
Normal
Boost
(dBA)
(dBA)

Model

Casing
Colour

Fan-Only

Hydronic

Hydronic
Ecovector LL 2800

1.0 (3250)

1.2 (4200)

Ecovector LL 2800

37

42

White

n/a

Ecovector LL 2000

0.7 (2500)

0.8 (2900)

Ecovector LL 2000

35

40

White

n/a

Ecovector LL 1200

0.4 (1250)

0.5 (1600)

Ecovector LL 1200

32

38

White

n/a

Heat outputs tested in accordance with BS4856 using entering water temperature.
Flow & Return
Connections

Mains
Cable

Ecovector LL 2800

15mm

Ecovector LL 2000

15mm

Ecovector LL 1200

15mm

Model

Sound levels measured at 1.5m.


Total Power Consumption
Normal
Boost
Water Capacity
(Watts)
(Watts)
(Litres)

Transformer

Flexible
Hoses

Isolating
Valves

Fused
Spur

1.5m

n/a

n/a

n/a

3A

43

76

1.5m

n/a

n/a

n/a

3A

26

55

0.58

1.5m

n/a

n/a

n/a

3A

17

21

0.29

Hydronic
0.83

Ecovector low level


A

Finish

115

Front casing: zinc coated steel. Polyester powder-coated:


textured white BS 4800 00A01 18% gloss
Side panels: polymer eggshell white
Installation

15

Mounting bracket supplied

445

37

Unit must be earthed


Suitable for two-pipe central heating systems
Minimum height above floor level 150mm

98

Maximum height above floor level 500mm


Commissioning
Check water is hot enough to activate the selectable low
temperature cut-out thermostat

36

68
33 Pipe centres

Electrical supply
in this side

All dimensions in mm

Controls

150

Model
LL 1200
LL 2000
LL 2800

a
635
1025
1385

Rocker switch - normal/off/boost


Built-in room thermostat
Low temperature cut-out thermostat set to energise fan at
approximately 35C

www.smiths-env.com/commercial

2. Products with aC motors

Ecovector / Sterling High

The Ecovector and Sterling Hydronic and Hydronic Low Voltage fan convectors provide
effective and dependable heating for both small and large commercial areas, fitted
unobtrusively above head height. They work particularly well in shops and libraries, where
lower wall space is limited. Supplied as standard in white but casing can be supplied in any
colour.

Heat Output at 80C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 75C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 70C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 65C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Ecovector HL 4000

4.0 (13500)

5.3 (18000)

3.7 (12500)

4.8 (16500)

3.3 (11300)

4.4 (15100)

3.0 (10400)

4.1 (13900)

Ecovector HL 2900

2.9 (10000)

4.2 (14500)

2.7 (9200)

4.0 (13500)

2.5 (8500)

3.5 (12000)

2.3 (7700)

3.2 (11000)

Ecovector HL 2300

2.3 (7850)

3.1 (10500)

2.1 (7000)

2.8 (9400)

1.9 (6400)

2.5 (8500)

1.7 (5700)

2.1 (7300)

Ecovector HL 1000

1.0 (3500)

1.3 (4600)

1.0 (3300)

1.2 (4050)

0.9 (3100)

1.1 (3750)

0.8 (2800)

1.0 (3400)

Sterling 1000-240V

1.0 (3500)

1.3 (4600)

1.0 (3300)

1.2 (4050)

0.9 (3100)

1.1 (3750)

0.8 (2800)

1.0 (3400)

Ecovector HL 1000-12V

1.0 (3500)

1.3 (4600)

1.0 (3300)

1.2 (4050)

0.9 (3100)

1.1 (3750)

0.8 (2800)

1.0 (3400)

Sterling 1000-12V

1.0 (3500)

1.3 (4600)

1.0 (3300)

1.2 (4050)

0.9 (3100)

1.1 (3750)

0.8 (2800)

1.0 (3400)

Model

Heat Output at 60C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 55C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 50C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 45C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Ecovector HL 4000

2.7 (9100)

3.4 (11500)

2.4 (8200)

3.2 (10900)

2.1 (7150)

2.8 (9600)

1.8 (6300)

2.5 (8400)

Ecovector HL 2900

2.1 (7200)

2.9 (9800)

1.9 (6600)

2.6 (8900)

1.6 (5400)

2.3 (7800)

1.4 (4750)

2.0 (6800)

Ecovector HL 2300

1.4 (4800)

1.9 (6600)

1.4 (4700)

1.8 (6300)

1.2 (4100)

1.6 (5500)

1.1 (3600)

1.4 (4800)

Ecovector HL 1000

0.7 (2550)

0.9 (3200)

0.6 (2100)

0.8 (2750)

0.5 (1850)

0.7 (2400)

0.5 (1600)

0.6 (2000)

Sterling 1000-240V

0.7 (2550)

0.9 (3200)

0.6 (2100)

0.8 (2750)

0.5 (1850)

0.7 (2400)

0.5 (1600)

0.6 (2000)

Ecovector HL 1000-12V

0.7 (2550)

0.9 (3200)

0.6 (2100)

0.8 (2750)

0.5 (1850)

0.7 (2400)

0.5 (1600)

0.6 (2000)

Sterling 1000-12V

0.7 (2550)

0.9 (3200)

0.6 (2100)

0.8 (2750)

0.5 (1850)

0.7 (2400)

0.5 (1600)

0.6 (2000)

Model

Heat Output at 40C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Model
Hydronic

Hydronic low Voltage

Hydronic

Hydronic low Voltage

Hydronic
Ecovector HL 4000

1.6 (5300)

2.1 (7000)

Ecovector HL 2900

1.2 (4000)

1.7 (5700)

Ecovector HL 2300

0.9 (3000)

1.2 (4000)

Ecovector HL 1000

0.4 (1350)

0.5 (1800)

Sterling 1000-240V

0.4 (1350)

0.5 (1800)

Ecovector HL 1000-12V

0.4 (1350)

0.5 (1800)

Sterling 1000-12V

0.4 (1350)

0.5 (1800)

Hydronic low Voltage

Heat outputs tested in accordance with BS4856 using entering water temperature.

10

www.smiths-env.com/commercial

Sound Levels
Normal
Boost
(dBA)
(dBA)

Model

Casing
Colour

Fan-Only

Hydronic
Ecovector HL 4000

39

52

White

Ecovector HL 2900

37

51

White

Ecovector HL 2300

34

50

White

Ecovector HL 1000

32

40

White

Sterling 1000-240V

32

40

White

Ecovector HL 1000-12V

32

39

White

Sterling 1000-12V

32

39

White

Hydronic low Voltage

Sound levels measured at 1.5m.

Flow & Return


Connections

Mains
Cable

Ecovector HL 4000

22mm

Ecovector HL 2900

15mm

Ecovector HL 2300

Power Consumption
Normal
Boost
(Watts)
(Watts)

Transformer

Flexible
Hoses

Isolating
Valves

Fused
Spur

1.5m

n/a

n/a

n/a

3A

40

60

1.04

1.5m

n/a

n/a

n/a

3A

33

50

0.52

15mm

1.5m

n/a

n/a

n/a

3A

20

32

0.32

Ecovector HL 1000

15mm

1.5m

n/a

n/a

n/a

3A

20

25

0.28

Sterling 1000-240V

15mm

1.5m

n/a

n/a

n/a

3A

20

25

0.28

Ecovector HL 1000-12V

15mm

0.45m

n/a

n/a

3A

20

25

0.28

Sterling 1000-12V

15mm

0.45m

n/a

n/a

3A

20

25

0.28

Model

Water Capacity
(Litres)

Hydronic

Hydronic low Voltage

Ecovector/Sterling High level

Wall mounted room thermostat

Finish
Front casing: zinc-coated steel. Polyester powder-coated: textured
white BS 4800 00A01 18% gloss
Side panels: polymer eggshell white
Installation
Maximum installation height 2.1m (611) to underside
No top or side clearance required

Ecovector Hl 1000, 1000-12V, 2300, 2900

Unit must be earthed (except model 1000-12V)

Suitable for two-pipe central heating systems

Electrical supply
in this side

Patress box not supplied for transformer (model 1000-12V)


Commissioning
Check water is hot enough to activate the selectable low
temperature cut-out thermostat. The inclusion of an automatic air
vent at the highest point is recommended to avoid possible air locks

Pipe Centres
88
25

80
37
96

276

112

Controls

Model
1000
1000-12V
2300
2900
4000

a
470
470
781
1062
1412

Two rocker switches - normal/off/boost, heating/fan-only


Low temperature cut out thermostat, set to energise fan at
approximately 35C

124

Ecovector Hl 4000

accessory

Electrical supply
in this side

Wall mounted room thermostat

A
Pipe Centres
690

78
35
100

112

276

All dimensions in mm

11

124

www.smiths-env.com/commercial

2. Products with aC motors

Eco-Powerad

The Eco-Powerad is the fan convector of the future - energy efficient, responsive and
suitable for installation within most wet central heating systems, driven by either boilers or
low temperature renewable technology. Compact, with smooth lines to achieve visual
simplicity, the Eco-Powerad also features low surface temperature casing for complete
safety and possesses a very low operating sound - between 28 and 32 decibels. Supplied
as standard in white but can be supplied in any colour.

Heat
Output
at 80C
kW (Btu/h)

Heat
Output
at 75C
kW (Btu/h)

Heat
Output
at 70C
kW (Btu/h)

Eco-Powerad 2000

3.9 (13200)

3.5 (11950)

3.2 (10900)

2.8 (9550)

2.5 (8525)

2.2 (7675)

2.0 (6800)

1.7 (5800)

1.3 (4600)

Eco-Powerad 1500

2.6 (8900

2.4 (8200)

2.2 (7500)

2.0 (6825)

1.9 (6475)

1.7 (5800)

1.5 (5100)

1.2 (4100)

0.9 (3100)

Eco-Powerad 1000

2.4 (8200)

2.1 (7150)

1.8 (6100)

1.6 (5450)

1.4 (4775)

1.2 (4100)

1.0 (3400)

0.8 (2725)

0.7 (2400)

Eco-Powerad 500

0.9 (3100)

0.8 (2900)

0.8 (2750)

0.7 (2400)

0.6 (2050)

0.5 (1875)

0.5 (1700)

0.4 (1375)

0.3 (1050)

Model

Heat
Output
at 65C
kW (Btu/h)

Heat
Output
at 60C
kW (Btu/h)

Heat
Output
at 55C
kW (Btu/h)

Heat
Output
at 50C
kW (Btu/h)

Heat
Output
at 45C
kW (Btu/h)

Heat
Output
at 40C
kW (Btu/h)

Hydronic

At inlet water temperatures of 75C and below, all Eco-Powerad models are classified as LST (low surface temperature) appliances.
Heat outputs tested in accordance with BS4856 using entering water temperature.
Model

Sound
Levels*
(dBA)

Casing
Colour

Flow &
Return
Connections

Mains
Cable

Transformer

Flexible
Hoses

Isolating
Valves

Fused
Spur

Total Power
Consumption
(Watts)

Water
Capacity
(Litres)

Eco-Powerad 2000

32

White

15mm

2m

n/a

n/a

n/a

3A

36

0.55

Eco-Powerad 1500

31

White

15mm

2m

n/a

n/a

n/a

3A

33

0.44

Eco-Powerad 1000

30

White

15mm

2m

n/a

n/a

n/a

3A

18

0.28

Eco-Powerad 500

28

White

15mm

2m

n/a

n/a

n/a

3A

15

0.17

Hydronic

*Measured at 1.5m.

Eco-Powerad
Finish
Front casing: zinc coated steel
Polyester powder-coated: white RAL 9010
Installation
Mounting bracket supplied
Unit must be earthed

Wall mounted room thermostat


95

Suitable for two-pipe central heating systems

Minimum height above floor level 150mm


Maximum height above floor level 500mm
Commissioning
Check water is hot enough to activate the low temperature
cut-out thermostat. Ensure system is balanced for even
heat distribution

332

400

Controls
Low temperature cut-out thermostat, set to energise fan at
approximately 35C

38

Suitable for thermostatic radiator valves (TRV) - not supplied

150 min

Rocker switch - normal/low

26

Electrical supply
in this side

All dimensions in mm

accessory

26

Model
Eco-Powerad 2000
Eco-Powerad 1500
Eco-Powerad 1000
Eco-Powerad 500

A
1570
1210
845
485

Wall mounted room thermostat.

12

www.smiths-env.com/commercial

2. Products with aC motors

Ecovector Vertical

Ecovector Vertical is ideal for those hard to heat places, such as reception areas and
alcoves. Ecovector can heat up a room more quickly than radiators, thereby reducing the
amount of time your boiler or heat pump is running - making it extremely efficient and
cost effective. Ideal for new and existing developments, due to ease of installation.
Supplied as standard in white but can be supplied in any colour.

Heat Output at 80C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 75C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 70C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 65C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Ecovector VE 2500

2.5 (8500)

2.3 (7800)

2.0 (6900)

1.9 (6400)

Model

Heat Output at 60C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 55C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 50C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Heat Output at 45C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Ecovector VE 2500

1.7 (5800)

1.5 (5100)

1.5 (5200)

1.3 (4400)

1.1 (3800)

Model

Heat Output at 40C


Normal
Boost
kW (Btu/h)
kW (Btu/h)

Casing
Colour

Fan-Only

White

n/a

Model
Hydronic

2.6 (8800)

2.4 (8200)

2.1 (7300)

2.0 (6700)

Hydronic
1.8 (6000)

1.3 (4600)

1.1 (3900)

Hydronic
Ecovector VE 2500

0.9 (3200)

1.0 (3400)

Heat outputs tested in accordance with BS4856 using entering water temperature.

Sound Levels
Normal
Boost
(dBA)
(dBA)

Model
Hydronic
Ecovector VE 2500

Model

36

Flow & Return


Connections

Mains
Cable

15mm

1.5m

39

Transformer

Flexible
Hoses

Isolating
Valves

Fused
Spur

n/a

n/a

n/a

3A

Power Consumption
Normal
Boost
(Watts)
(Watts)

Water Capacity
(Litres)

Hydronic
Ecovector VE 2500

28

36

0.75

Ecovector Vertical
Finish
Front casing and side panels: zinc-coated steel. Polyester
powder-coated: textured white BS 4800 00A01 18% gloss
Installation
Mounting bracket supplied
Unit must be earthed
Suitable for two-pipe central heating systems
Minimum height above floor level 150mm, maximum
height above floor level 500mm
Commissioning
Check water is hot enough to activate the selectable low
temperature cut-out thermostat
Controls
Rocker switch - normal/off/boost
All dimensions in mm

Low temperature cut-out thermostat set to energise fan at


approximately 35C
Wireless wall mounted thermostat included with this product

13

www.smiths-env.com/commercial

3. natural Convectors (perimeter heating)

Sureline

The Sureline provides gentle, discreet and efficient low-level warmth and is the ideal
heating solution for areas where wall space is limited - rooms such as showrooms or
waiting areas. Simple to install along the skirting in any room, Sureline is an efficient
natural convector that provides discreet heating. Supplied as standard in white but casing
can be supplied in any colour.

Heat Output
50C

Btu/h/m @ average water temperature


55C 60C 65C 70C 75C

80C

50C

W/m @ average water temperature


55C 60C 65C 70C 75C

80C

920 (200)

1310

1570

1820

2070

2300

2560

2810

380

460

530

610

670

750

820

Bottom supply - Top return 920 (200)

1030

1250

1460

1710

1920

2140

2330

300

370

430

500

560

630

680

Two supplies - Parallel

Flow Rate
L/h (G/h)

76

38

All heat outputs relate to 1 metre length


17
Length
includes
casing,
element,
backplate
and joining
strip

Backplate
Element

179

180

68
Front
casing

31

Length A

Joining strip

74.5
172

LH and
RH valve
box/end
stop kit (RH
shown)

152

25mm overlap
on cover

Minimum
overlap
20mm

180

75

180

Body with open


bottom

75

Sureline

75

17

126.5

Centre valve cover


75.5

75.5

75.5

125
81.5

Finish
Outer casing 0.7mm zinc coated steel. Polyester powdercoated. Paint specification: textured white BS 4800 00A01
18% gloss. Each length includes casing, element, backplate
and joining strip. Casing only includes casing, backplate and
joining strip

92.5

75.5
128.5

60.5

51

Installation

51

Minimum clearance above floor 50mm

Plan view

92.5

81.5

125

75.5

75.5

75.5

75.5
Plan view

Plan view

Plan view

Flow and return connections 22mm copper


Designed for system pressures up to 10 bar
Suitable for two-pipe central heating systems only

180

180

180

180

attachments
Casing only (1000mm)
LH valve box/end cap kit

RH valve box/end cap kit

Centre valve cover

90 internal cover

90 external cover

135 internal cover

135 external cover

Finger guard 500 (500mm)

Finger guard 1000 (1000mm)

Element (1000mm)

Customised requirements
We are able to offer casings painted in any colour. Price and
availability will be confirmed at the time of order

90 External corner
Finger guard

90 Internal corner

135 Internal corner

All dimensions in mm

Sureline 2000
Sureline 1500
Sureline 1000
Sureline 500

74

500 or 1000

*We recommended the use of finger guards in installations


where infants have access to the underside of Sureline.

14

Model

135 External corner

length
a (mm)
2000
1500
1000
500

* casing only

www.smiths-env.com/commercial

4. Electric heaters

Skyline

The electric Skyline fits neatly into existing ceiling space - replacing a 600mm x 600mm
ceiling tile and because it is ceiling mounted, it saves valuable wall space - particularly
important in retail units. It is unobtrusive and effective. Like its hydronic cousin, this highoutput fan convector effectively heats large areas. Supplied as standard in white but can
be supplied in any colour.

Model
Electric

Heat Output (kW)


Normal
Boost

Skyline E 4kW

4.0

Power Consumption (kW)


Normal
Boost

4.0

4.1

4.1

Fused
Spur

Mains
Cable (m)

Sound
Levels (dBA)

Casing
Colour

Fan-Only

20A

1.5

40

White

n/a

Skyline E 4kW
Finish
Outer casing 0.9mm zinc-coated steel. Polyester powdercoated
Paint specification: textured white, BS 4800 00A01 18% gloss

Skyline E 4kW

Installation

Maximum installation height 3.2m (10'6") to underside

507

Minimum 150mm void space required for recessed


installation

151

Not suitable for bathrooms and other high humidity areas


Two air inlet options: room only, room and void
Maximum flexibility in installation: only 600mm - side
clearance required

600

15

Facility for connection to 6mm threaded rod or chains


(rods and chains - not supplied)
248
centres

20 amp fused spur required


Unit must be earthed
Supplied with remote operating switch

264

600

Controls
Rocker switches for fan and element
Overheat protection: thermal cut-out. Manual reset procedure:
switch power off at mains, wait 5 minutes, switch power on

Multiple positions (14) for suspension points

accessories
Surface mounting kit - 135mm. Provides a complete foursided trim when fitted to a solid ceiling
Ceiling tile spacer - 85mm. Provides semi-recessed profile to
match Skyline CT18 when used in ceiling tile frame

additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.
Hydronic model available.

Room thermostats used in conjunction with Skyline E 4kW


must be rated at 20A minimum

15

www.smiths-env.com/commercial

4. Electric heaters

Sterling
The Sterling fan-assisted electric heater is a great low cost solution providing effective and
dependable heating for both small and large commercial areas, fitted unobtrusively above
head height. It has been designed for rooms with limited lower wall space, such as shops
and libraries, in mind. Supplied as standard in white but casing can be supplied in any
colour.

Model
Electric

Heat Output (kW)


Normal
Boost

Power Consumption (kW)


Normal
Boost

Fused
Spur

Mains
Cable (m)

Sound
Levels (dBA)

Casing
Colour

Fan-Only

Sterling E 4kW

2.0

4.0

2.0

4.1

20A

2.0

47

White

Sterling E 2kW

1.0

2.0

1.0

2.0

10A

2.0

40

White

Sterling E 2kW PC

1.0

2.0

1.0

2.0

10A

2.0

40

White

n/a

Sterling Electric
Finish
Outer casing with inlet grille zinc-coated steel. Polyester
powder-coated: textured white BS 4800 00A09 18% gloss
Installation
Maximum installation height 2.1m (611) to underside

Wall mounted room thermostat

Minimum top clearance of 150mm required


25 angled mounting brackets supplied (optional fitting)
Unit must be earthed

Sterling Electric E 2kW, E 2kW PC (Pull-Cord), E 4kW

Controls
110

Front

Rocker switches for fan and element 2kW and 4kW models
Pull-cord for fan and element 2kW PC model
Overheat protection: thermal cut-out

Side

168

Manual reset procedure: switch power off at unit or mains,


wait 5 minutes, switch power on
80

Room thermostats used in conjunction with 4kW models


must be rated at 16A minimum

Underside

accessory

Angled mounting
bracket option

2kW models - wall mounted room thermostat


25
A

All dimensions in mm

additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.

16

www.smiths-env.com/commercial

4. Electric heaters

Sygnet

Versatile and economic, low-level fan convectors giving a choice of surface or flush
mounting. Unobtrusive recessed installation means minimal projection beyond the surface
of the wall - ideal for those areas where space may be at a premium.

Model
Electric

Heat Output (kW)


Normal
Boost

Sygnet E 2kW

1.0

Power Consumption (kW)


Normal
Boost

2.0

1.0

2.0

Fused
Spur

Mains
Cable (m)

Sound
Levels (dBA)

Casing
Colour

Fan-Only

10A

2.0

49

White

Sygnet E
Finish
Front casing and surface mounting kit 0.9mm zinc coated
steel, polyester powder-coated. Paint specification: textured
white BS 4800 00A01. 18% gloss
Installation

Wall mounted room thermostat

May be recessed in stud walls or surface mounted


Brickwork installation requires wood frame (not supplied)
Unit must be earthed

Sygnet E

Controls

Recessed Wall
Mounting

Surface
Mounting

Three rocker switches, fan off/fan-only, 1kW, 2kW

359

Overheat protection: thermal cut-out


Manual reset procedure: switch power off at unit or mains,
wait five minutes, switch power on

Front

accessory

359

Wall mounted room thermostat

15

307

Underside

70
305

15

70
85

All dimensions in mm

additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.

17

www.smiths-env.com/commercial

4. Electric heaters

Space Saver
The Space Saver offers increased flexibility and space in kitchen design as it enables the
removal of radiators that may be using up valuable wall space. Fitting discreetly into the
plinth of a kitchen, the Space Saver provides efficient and effective heat at low level.

Before

Model
Electric
Space Saver SS2E

After

Heat Output (kW)


Normal
Boost
1.0

Power Consumption (kW)


Normal
Boost

2.0

1.0

2.0

Fused
Spur

Mains
Cable (m)

Sound
Levels (dBA)

Casing
Colour

Fan-Only

10A

2.0

42

Brushed Steel

Space Saver
Fascia grille Finish
Zinc coated steel polyester powder coated - metallic silver
(referred to as Brushed Steel)
Installation
Important: Correct fascia grille opening must be cut to
allow sufficient air intake
20mm clearance above unit required
Model secured to plinth by two screws
through fascia grille
Unit must be earthed

Wall mounted room thermostat


SS2E

290

91

accessories
Wall mounted room thermostat
Grilles: brown - RAL 8016, black - RAL 9005,
white - RAL 9010, chrome, aluminium, gold

240

Alternative grilles for SS2E fit over the supplied grille


Wall mounted control switch (white) to suit SS2E

105

105

Controls
100

Wall-mounted room thermostat


Overheat protection: thermal cut-out. Manual reset
procedure: switch power off at unit or mains, wait 5 minutes,
switch power on

485
500
All dimensions in mm

additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.
Hydronic models available.

18

www.smiths-env.com/commercial

How fan convectors work


Fan Convectors
Fan convectors require connection to a wet central heating
system and an electrical connection to run the fan. Hot water
from the central heating system passes through the heat
exchanger, transferring its heat to the aluminium fins. Cooler
air is drawn in by the fan and heated as it passes over the
heat exchanger before being expelled gently back into the
room. This gives a more even temperature and will heat a
room in much less time than a traditional panel radiator.

natural Convectors
(Perimeter Heating)
These require connection to a wet central heating system.
Hot water from the central heating system passes through
the heat exchanger, transferring its heat to the aluminium
fins. The natural movement of air gently circulates over the
heat exchanger, is warmed and evenly distributed around
the room.

Fan-assisted Electric Heaters


Connect to an electrical system via a fused spur. Fan-assisted
heaters cost around 15 pence per hour for each 1kW of heat.

Operation
Fan convectors will, if the heat output switch is left in either
the normal or boost position, come on and off automatically
with the central heating system. Each model includes a low
temperature cut-out system, which prevents the product
operating until the water temperature reaches a preset
temperature. Electric fan-assisted heaters are designed to be
switched on and off manually.

19

www.smiths-env.com/commercial

Happy to help
Smith's Environmental Products Ltd is one of the leading manufacturers of heating products in the UK. We are
committed to achieving the highest standards and our faith is supported by a free five year parts and labour
guarantee with every product. Our customer service is second to none and we are happy to offer any help and
guidance that you might need.
Stockists
All products are available nationally from Builders Merchants, Plumbers Merchants, Heating Equipment
Distributors and Kitchen Equipment Distributors. In the event of difficulty, please contact us or visit our website
www.smiths-env.com for details of your nearest stockist.
Information and advice
A product brochure containing full technical specifications and list prices is available to download from our
website or in hard copy from our office. Also available on our website are price lists, individual product data
sheets, installation & user guides, where to buy, who to contact and a media centre.
Alternatively contact our office 9.00am to 5.00pm Monday to Thursday, 9.00am to 4.00pm on Friday.

For product information, customer services or sales support call us on

01245 324900
sales@smiths-env.com
Smith's Environmental Products Ltd
Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW

www.smiths-env.com/commercial

Think Fan Convector, Think Smiths


October 2014