You are on page 1of 8

Questionnaire for preparing offers for

GESTRA Condensate Recovery and


Return Systems
GESTRA Fax: ++49 (0) 421 - 35 03 566
Condensate flowrate

Discharge control:

Condensate temperature

Level electrode

Condensate pressure

Supply options:

Tank design:

Cylindrical

Rectangular

Horizontal

Vertical

Condensate pumps:

Accessories
detached

No accessories

yes

Accessories assembled
and interconnected

no

Condensate tank made of:

Qty.

Discharge head

Steel

Stainless steel grade 1.4571


(X 6 CrNiMoTi 17-12-2)

Mains voltage

Horizontal pump

Vertical pump

Submersible pump

Typical Installations

Condensate receiver
tank of cylindrical
design type SD L (S)
with high-pressure
centrifugal pump(s)
installed next to tank
L = horizontal design
S = vertical design

Closed System
Condensate receiver
tank of cylindrical
design type SD L (S)
with horizontal-type
centrifugal pump(s)
installed next to tank
L = horizontal design
S = vertical design

Condensate tank of rectangular


design type SDR A with highpressure centrifugal pump(s)
installed next to tank

Condensate tank of rectangular


design type SDR I with submersible condensate pump(s)
bolted on top

Open System

Name/Title
Company Name
Telephone
Fax
E-mail
Date

149

Questionnaire for preparing offers for


GESTRA Desuperheating Plants
GESTRA Fax: ++49 (0) 421 - 35 03 566
Cooling fluid:

Reducing of steam pressure


If yes,

yes

P4

no

Self-acting control

bar/psi upstream
of cooler

Electric

Electro-pneumatic

Steam flowrate
Steam pressure:

t4

C upstream of cooler

if not fitted

with pump

Water-bath desuperheater

Injection cooler

yes

no

t3 = ts
t3 = ts +>5 controllable

Supply options for water-bath desuperheater:


P1

bar/psi upstream of pressure reducing station

P2

bar/psi downstream of pressure reducing station


or when no more pressure reduction takes place
bar/psi downstream of cooling station

Accessories detached

Accessories assembled

Excess temperature
protection

Optional equipment:

High-temperature alarm

Steam temperature:

Low-water level alarm

t1 or
t2

Special requirements concerning cooler:

P3

t3

C upstream of pressure reducing station or


when no more pressure reduction takes place
C downstream of cooling station

Material

Steel

Stainless steel grade 1.4571


(X 6 CrNiMoTi 17-12-2)

Typical Installations

System 1
Injection cooler with fixed jet orifices

System 3
Water-bath desuperheater

Name/Title
Company Name
Telephone
Fax
E-mail
Date

150

Questionnaire for preparing offers for


GESTRA Steam Regenerators
GESTRA Fax: ++49 (0) 421 - 35 03 566
Thermal output
Service data (primary)
Medium:

Pressure

Steam

bar/psi

Temperature

Flowrate

bar/psi

Temperature

Flowrate

Hot water

Thermal oil

Services data (secondary)


Medium:

Pressure

Steam

Control (pressure side)

Self-acting

Feedwater control

Solenoid valve or motorized valve

Electric

Pneumatic

Feedwater pump

Application

Typical Installations
Steam regenerator

Condensate

Feedwater

Internittent/continuous
boiler blowdown

Heating steam

Pure steam

Name/Title
Company Name
Telephone
Fax
E-mail
Date

151

Questionnaire for preparing offers for


GESTRA Deaerating Plants
GESTRA Fax: ++49 (0) 421 - 35 03 566
Boiler capacity
Make-up water flowrate

Temperature approx.

Steam pressure
Service pressure (deaerator)
Make-up feed control
Pressure control

Electric
Self-acting

Pneumatic

Electric

Boiler
blowdown

Typical Installation

Condensate

Name/Title
Company Name
Telephone
Fax
E-mail
Date

152

Pneumatic

Questionnaire for preparing offers for


GESTRA Flash Vessel Systems
GESTRA Fax: ++49 (0) 421 - 35 03 566
Pressure p 1 upstream of steam trap at steam user
(boiler pressure at flash vessel)

P1 =

bar(a)/psi(a)

Pressure p 2 of flash steam at flash outlet to low pressure systemP2 =

bar(a)/psi(a)

Pressure p 3 downstream of steam trap after the flash vessel

P3 =

bar(a)/psi(a)

Condensate flowrate to flash off

m=

kg/h

Flash vessel material


Please state all pressure specifications in bara or psia!

Typical Installation
Flash-steam outlet

P2

Condensate from
H.P. user

P1
Gas balance pipe

to condensate tank

P3

Drain

Name/Title
Company Name
Telephone
Fax
E-mail
Date

153

Questionnaire for preparing offers for


GESTRA Blowdown Receiver (Mixing Cooler)
GESTRA Fax: ++49 (0) 421 - 35 03 566
Hot-water flowrate

Material

Hot-water temperature

Hot-water pressure

Application

Cooling-water temperature

Steel

Stainless steel grade 1.4571


(X 6 CrNiMoTi 17-12-2)

Boiler blowdown

Other

Cooling-water pressure

Typical Installation
Mixing cooler with cooling-water control and, on request, with additional flash-steam condensation
Flash-steam discharge
or vent

Cooling water

Hot water from


blowdown, overflow
etc.

Thermostat

Drain

Mixed cooled water to drain

Name/Title
Company Name
Telephone
Fax
E-mail
Date

154

Questionnaire for preparing offers for


GESTRA Heat Exchanger
GESTRA Fax: ++49 (0) 421 - 35 03 566
Thermal output

Control

Service data (primary)


Medium:

Pressure
Material:

Steam
bar/psi

Steel

Hot water

Temperature

Thermal oil

Flowrate

Self-acting

Design

Electric

Pneumatic

Controlled from the


condensate side

Stainless steel grade 1.4571


(X 6 CrNiMoTi 17-12-2)

Horizontal

Vertical

Service data (secondary)


Medium:

Pressure
Material:

Steam
bar/psi

Steel

Hot water

Temperature

Thermal oil

Flowrate

Stainless steel grade 1.4571


(X 6 CrNiMoTi 17-12-2)

Typical Installation
Hot water
inlet

GESTRA Heat Exchanger controlled from the steam side


with constant temperature of the secondary circuit

Heating steam

Hot water
return
1

Heating circuit supply


Condensate
Steam inlet

Heating circuit return


Condensate outlet

GESTRA Heat Exchanger controlled from the condensate side as a function of the
outside temperature and safety shut-down controlled from the steam side

Name/Title
Company Name
Telephone
Fax
E-mail
Date

155

Questionnaire for preparing offers for


GESTRA Steam Separator
GESTRA Fax: ++49 (0) 421 - 35 03 566
Medium:

Flowrate:

m
=

kg

Service pressure:

p=

bara/psia

Service temperature:

t=

Approved pressure:

p=

barg/psig

Approved temperature:

t=

Saturated steam

Superheated steam

VN =

Air

Gas

Nm3/h

Inspection and certification:


Connections:

Inlet/Outlet:

DN/PN

Condensate outlet: DN/PN


Material:

Connection arrangements:

Name/Title
Company Name
Telephone
Fax
E-mail
Date

156

S235JRG2
(RSt 37-2)

P265GH
(H II)

1.4541
(V2A)

1.4571
(V4A)

16 Mo 3

You might also like