General Arrangement

Legend
Plant

: Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department

: 111 - Limestone crushing

Contract

: 1345327

Approved date

: 06-Feb-2015

Created by

: MST

Approved by

: AC

Doc. No.:

50068083-3.0

General Arrangement Legend


Doc. No.

50068083-3.0

Plant:

Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department:

111 - Limestone crushing

The following documentation is prepared for each plant department:


1. General Arrangement Drawings.
2. Outline and load drawings.
3. General arrangement legend.
1. The purposes of the General arrangement drawings are to :
Show the general equipment arrangement.
Provide the civil designer with equipment loads for structural design.
Provide erection information.
2. Outline and load drawings are detailed drawings of the equipment
3. A legend is a text accompanying General Arrangement Drawings.
Page 3 is a key to symbols, used on the General Arrangement Drawings.
Page 4 contains the document numbers of the General Arrangement Drawings.
The next pages in the legend specify:
Ref. No.:
Document No.:
Doc vers.:
Description:

Reference numbers which refer to General Arrangement Drawings.


Document number.
Version number of document.
Designation of equipment.

Supply Key:
SSS = Seller supply on Seller Specification or documentation.
SLM = Seller supply using local manufacturing.
CSD = Contractor supply on Seller Documentation. (Contractor manufacturing).
CSS = Contractor supply on Seller Basic Specification. (Contractor Engineering).
CCS = Contractor supply on Contractor Specification.
BSD = Buyer supply on Seller Documentation (Buyer manufacturing).
BSS = Buyer supply on Seller Basic Specification (Buyer engineering).
BBS = Buyer supply on Buyer Specification.
Customer equipment No.: Equipment numbers referring to the contract and the Flow
Diagram.
Equipment No.: Equipment numbers referring to the contract and the Flow Diagram.
Drawings must be read in conjunction with instruction manual No. 749500 Structural
design and erection, General requirements, covering:
Installation dimensions, access conditions, loads, etc.
NOTE:
In order to comply with world wide recognized designations, FLSmidth has introduced new
designations for their plant documentation.
As both old and new designations may appear at the same time, below is a key for
translation.
Old designation
Foundation and Erection drawing. (F&E)
Standard F&E drawing. (Std. F&E)
Separate F&E drawing. (Sep. F&E)

New designation
General Arrangement Drawing. (GA)
Outline and Load Drawing. (OL)
Outline and Load Drawing. (OL)

The information transmitted by this document is the proprietary and confidential property of FLSmidth
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

2/7

General Arrangement Legend


Doc. No.

50068083-3.0

Plant:

Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department:

111 - Limestone crushing


Key to symbols
Datum point/centre
of gravity

True North

ISO 7519

ISO 129

Earth

Grating

Center Line

Flow Direction

ISO 128-24

ISO 81714-1

Embossed plate

Concrete

Hole

ISO 7519

Recess

ISO 7519

Grouting-up

Railing

Stairs (arrow means


upwards)

Ramp (arrow means


upwards)

ISO 7519

Revision

Estimated

Insulation

, the loads are only specified on outline and load

, see OL drawing or erection

Levels Vertical
Steel Structure

ISO 129-1

Slope
Secondary Platform

ISO 129-1

Levels Horizontal
Concrete Structure

ISO 129-1

Interrupted line

ISO 128-23

For equipment with reference Nos. and consecutive Nos.


documentation.

ISO 129-1

Hold

ISO 7519

For equipment with reference Nos. with


drawings.

Concrete Structure

ISO 7519

ISO 7519

Steel Structure

ISO 129-1

Secondary Platform

ISO 129-1

ISO 129
Direction and %
of slope
(arrow means
descent)

ISO 7519

NOTE (Levels): Levels are either top of concrete or top of steel structure, without grating or
embossed plate. Levels marked * indicate the elevation to the top of the grating or embossed
plate.
The information transmitted by this document is the proprietary and confidential property of FLSmidth
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

3/7

General Arrangement Legend


Doc. No.

50068083-3.0

Plant:

Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department:

111 - Limestone crushing

13093817

Doc.
Vers.
3.0

13093818

3.0

Plan No. 1

13093819

3.0

Plan No. 2

13093820

3.0

Plan No. 3

13093821

3.0

Plan No. 4

13093822

3.0

Plan No. 5

13093823

2.0

Plan No. 6

13093824

2.0

Plan No. 7

749500

13.0

Structural design and erection.

931250

4.0

Document No.

Description
Plan No. 0

FLS-Low-pressure Flanges

The information transmitted by this document is the proprietary and confidential property of FLSmidth
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

4/7

General Arrangement Legend


Doc. No.

50068083-3.0

Plant:

Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department:

111 - Limestone crushing

Ref.
No.

Document No.

Doc.
Vers.

Description Supply Key

Customer
Ref. No.

Equipment
No.

20137692
Pending

1.0

Lining,
for concrete hopper
SSS

111.FY050

20137695
Pending

1.0

Lining,
for concrete hopper
SSS

111.FY055

60139990

2.0

Apron feeder AF 1800x12,


incl. Drive, Chain scraper
and Level indicator
SSS

111.AF060
111.SX061

60139990

2.0

Apron feeder AF 1300x14,


incl. Drive, Chain scraper
and Level indicator
SSS

111.AF065
111.SX066

60139990

2.0

Strike Bar Crusher 200x200,


for Limestone
SSS

111.HC10
0

60139746

1.0

Main drive station,


for Strike Bar Crusher
SSS

111.HC10
0

Pending

Slip Resistor
SSS

111.HC10
0

Pending

Capacitor bank
SSS

111.HC10
0

Pending

Rotor starter
SSS

111.HC10
0

Belt Conveyor RFBE-B2000


SSS

111.BC200

Drive
SSS

111.BC200

Belt Conveyor RT45-A1000,


incl. Belt Weigher and
Spillage Conveyor
SSS

111.BC210
111.SX211

Drive
SSS

111.BC210

10

20137630

11

Pending

12

20137742

13

Pending

1.0

1.0

The information transmitted by this document is the proprietary and confidential property of FLSmidth
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

5/7

General Arrangement Legend


Doc. No.

50068083-3.0

Plant:

Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department:

111 - Limestone crushing

Ref.
No.

Document No.

Doc.
Vers.

14

10158593

5.0

Jet pulse filter CE2-10-25,


incl. screw conveyor
SSS

111.BF300
111.SC301

15

2.203992

2.0

Sluice flap PE 200 CW,


2 pcs.
SSS

111.FV302

16

1.248254

8.0

Fan SPW 100/95 VL,


Pos.: RD 270
Handing : D
incl. drive unit
SSS

111.FN303

17

30000167

6.0

Silencer MK10V
1200x1200x1500
SSS

111.FN303

18

Pending
2.244449

Dedusting pipes,
incl. supports
SSS

111.XA30
4

7.0

19

3.203521

6.0

Set of Throttle valves


HAW
SSS

111.XA30
4

20

No Drawing

Chutes,
incl. wear protected
SSS

111.XA91
0

21

No Drawing

Travelling crane 40 t
Client

111.CA900

22

3.222433

23

24

2.0

Description Supply Key

Customer
Ref. No.

Equipment
No.

Base plate with anchor irons


200x200
Civil

No drawing

Support face area,


for equipment
Civil

No drawing

Drop zone
Civil

The information transmitted by this document is the proprietary and confidential property of FLSmidth
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

6/7

General Arrangement Legend


Doc. No.

50068083-3.0

Plant:

Nyumba Ya Akiba-Cement Plant 3000 TPD


Songololo DRC

Department:

111 - Limestone crushing

Ref.
No.

Document No.

25

No drawing

26

3.128743

27

28

Doc.
Vers.

Description Supply Key

Customer
Ref. No.

Equipment
No.

The room must be kept


clean and free from dripping
water. Vibration and dust
must be minimized.
The temperature must be
between 0C- 40C and with
a variation within 10C,
over a 24-hour period.

7.0

Opening,
for cables
Civil

3.128743

7.0

Opening 250x250,
for cables
Civil

3.128743

7.0

Opening 300x300,
for cables
Civil

The information transmitted by this document is the proprietary and confidential property of FLSmidth
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

7/7