Bulletin PD-20765 rev.

A 02/04

15ETH06FP
Hyperfast Rectifier
Features

trr = 22ns typ.


IF(AV) = 15Amp
VR = 600V

Hyperfast Recovery Time


Low Forward Voltage Drop
Low Leakage Current
175C Operating Junction Temperature
Fully Isolated package (VINS = 2500 VRMS)
UL E78996 approved

Description/ Applications
State of the art Hyperfast recovery rectifiers designed with optimized performance of forward voltage drop,
Hyperfast recover time, and soft recovery.
The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in PFC Boost stage in the AC-DC section of SMPS, inverters or as freewheeling
diodes.
The IR extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.

Absolute Maximum Ratings


Parameters

Max

VRRM

Peak Repetitive Peak Reverse Voltage

IF(AV)

Average Rectified Forward Current

IFSM

Non Repetitive Peak Surge Current

IFM

Peak Repetitive Forward Current

30

TJ, TSTG

Operating Junction and Storage Temperatures - 65 to 175

Units

600

@ TC = 80C

15

@ TJ = 25C

180

Case Styles

15ETH06FP

Cathode

Anode

TO-220 FULLPACK
www.irf.com

15ETH06FP
Bulletin PD-20765 rev. A 02/04

Electrical Characteristics @ TJ = 25C (unless otherwise specified)


Parameters
VBR, Vr

Breakdown Voltage,
Blocking Voltage

VF

Forward Voltage

Min Typ Max Units Test Conditions


600

IR = 100A

1.8

2.2

IF = 15A, TJ = 25C

1.3

1.6

IF = 15A, TJ = 150C

0.2

50

VR = VR Rated

IR

Reverse Leakage Current

30

500

TJ = 150C, VR = VR Rated

CT

Junction Capacitance

20

pF

VR = 600V

LS

Series Inductance

8.0

nH

Measured lead to lead 5mm from package body

Dynamic Recovery Characteristics @ TC = 25C (unless otherwise specified)


Parameters
trr

Min Typ Max Units Test Conditions

Reverse Recovery Time

IRRM

Peak Recovery Current

Reverse Recovery Charge

Qrr

22

30

28

35

ns

IF = 1A, diF/dt = 100A/s, VR = 30V

29

TJ = 25C

75

TJ = 125C

3.5

57

300

IF = 15A, diF/dt = 100A/s, VR = 30V

IF = 15A

TJ = 25C

diF /dt = 200A/s


VR = 390V

TJ = 125C
nC

TJ = 25C
TJ = 125C

trr

Reverse Recovery Time

51

ns

IRRM

Peak Recovery Current

20

Qrr

Reverse Recovery Charge

580

nC

IF = 15A

TJ = 125C

diF /dt = 800A/s


VR = 390V

Thermal - Mechanical Characteristics


Parameters

Min

Typ

Max

Units
C

TJ

Max. Junction Temperature Range

175

TStg

Max. Storage Temperature Range

- 65

175

RthJC

Thermal Resistance, Junction to Case

Per Leg

3.0

3.5

RthJA

Thermal Resistance, Junction to Ambient

Per Leg

70

RthCS

Thermal Resistance, Case to Heatsink

0.5

Weight

2.0

Mounting Torque

C/W

0.07

(oz)

6.0

12

Kg-cm

5.0

10

lbf.in

Typical Socket Mount


Mounting Surface, Flat, Smooth and Greased

www.irf.com

15ETH06FP
Bulletin PD-20765 rev. A 02/04

1000

100

T J = 175C

Reverse Current - I R (A)

150C

10

125C

100C

0.1
25C

0.01

0.001
0

T = 175C
J

10

100

200

300

400

500

600

Reverse Voltage - VR (V)

T = 150C
J

Fig. 2 - Typical Values Of Reverse Current


Vs. Reverse Voltage

T = 25C
J

1000
Junction Capacitance - C T (pF)

Instantaneous Forward Current - I F (A)

100

1
0.5

T J = 25C

100

10
1

1.5

2.5

100

200

300

400

500

600

Forward Voltage Drop - VFM (V)

Reverse Voltage - VR (V)

Fig. 1 - Typical Forward Voltage Drop Characteristics

Fig. 3 - Typical Junction Capacitance


Vs. Reverse Voltage

Thermal Impedance Z thJC (C/W)

10

D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01

0.1

PDM

t1
t2

Single Pulse
(Thermal Resistance)

Notes:
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc

0.01
0.00001

0.0001

0.001

0.01

0.1

10

100

t1, Rectangular Pulse Duration (Seconds)


Fig. 4 - Max. Thermal Impedance Z thJC Characteristics

www.irf.com

15ETH06FP
Bulletin PD-20765 rev. A 02/04

35

160

Average Power Loss ( Watts )

Allowable Case Temperature (C)

180

140
120

DC

100
80
60 Square wave (D = 0.50)
40 80% Rated Vr applied
20 see note (3)
0

RMS Limit

25
20

D = 0.01
D = 0.02
D = 0.05
D = 0.1
D = 0.2
D = 0.5
DC

15
10
5
0

4
8
12
16
20
24
Average Forward Current - IF(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current

100

30

5
10
15
20
25
Average Forward Current - IF(AV) (A)
Fig. 6 - Forward Power Loss Characteristics

1000
V R = 390V
T J = 125C
T J = 25C

IF = 30 A
IF = 15 A

80

800
IF = 30 A
IF = 15 A

trr ( ns )

Qrr ( nC )

60

40

20

600

400

200
V R = 390V
T J = 125C
T J = 25C

0
100

1000

0
100

1000

di F /dt (A/s )

di F /dt (A/s )

Fig. 7 - Typical Reverse Recovery vs. di F /dt

Fig. 8 - Typical Stored Charge vs. di F /dt

(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;


Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR

www.irf.com

15ETH06FP
Bulletin PD-20765 rev. A 02/04

Reverse Recovery Circuit

VR = 200V

0.01
L = 70H
D.U.T.
diF /dt
dif/dt
ADJUST

D
IRFP250

Fig. 9- Reverse Recovery Parameter Test Circuit

trr

IF

tb

ta

Q rr
2

I RRM

0.5 I RRM
di(rec)M/dt

0.75 I RRM
1

diFf /dt

1. diF/dt - Rate of change of current through zero


crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current

4. Qrr - Area under curve defined by t rr


and IRRM
t rr x I RRM
Q rr =
2
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr

Fig. 10 - Reverse Recovery Waveform and Definitions

www.irf.com

15ETH06FP
Bulletin PD-20765 rev. A 02/04

Outline Table
10.6

HOLE 3.4

10.4

3.1

3.2

15.8

16.0

15.4

16.4

7.1
6.7

3.7

2.8
2.6

13.7

2.54
TYP.

0.9
0.7
2.54 TYP.

0.48
0.44
2.85
2.65

1.15
1.4

1.05

13.5

3.3

3.1

10

TYP

1.3

R0.7 (2 PLACES)
4.8
4.6

R0.5

5 0.5

5 0.5

Dimensions in millimeters

Ordering Information Table

Device Code

15

06

FP

Current Rating (15 = 15A)

= Single Diode

= TO-220

= HyperFast Recovery

Voltage Rating (06 = 600V)

TO-220 FULLPACK

www.irf.com

15ETH06FP
Bulletin PD-20765 rev. A 02/04

Data and specifications subject to change without notice.


This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.

IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 02/04

www.irf.com

You might also like