ITEM NO

DESCRIPTION

5A: SANITARY APPLIANCES


KITCHEN FIXTURES
Front of House Kitchen Fixtures
Supply and installation of kitchen fixtures and appliances including all
fittings, short pipe connections, supports, joints, fixing and accessories,
complete; all in accordance with the Drawings and Specification Section
224000

Two bedroom apartment (22nr)

Three bedroom apartment (10nr)

QUANTITY

UNIT

Carried to Collection

BATHROOM FIXTURES AND ACCESSORIES


Front of House Toilets
Supply and installation of bathroom fixture and accessories to public
areas including all fittings, short pipe connections, supports, joints, fixing
and accessories, complete; all in accordance with the Drawings and
Specification Section 102800 and 224000
A

SAN-PA-101 - Wall hung water closet

36

nr

SAN-PA-102 - Under counter basin

45

nr

SAN-PA-103 - Basin faucet

45

nr

SAN-PA-104 - Shower head

nr

SAN-PA-105 - Shower head - wall mounted

nr

SAN-PA-106 - Shower mixer

13

nr

SAN-PA-107 - Ablution horse

41

nr

SAN-PA-108 - Floor drain

60

nr

SAN-PA-109 - Shower drain (**)

nr

SAN-PA-201 - Wall hung water closet

nr

SAN-PA-202 - Lavatory

nr

SAN-PA-203 - Faucet with mixer

nr

SAN-PA-204 - Vertical grab rail

nr

SAN-PA-205 - Horizontal grab rail

nr

SAN-PA-206 - Swing up grab rail

nr

SAN-PA-207 - L shape grab rail

nr

SAN-PA-121 - Toilet paper holder

41

nr

SAN-PA-123 - Robe hook

52

nr

SAN-PA-124 - Water closet brush set

41

nr

SAN-PA-125 - Tissue dispenser

14

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-PA-126 - Tissue dispenser

nr

SAN-PA-127 - Tissue dispenser

nr

SAN-PA-301 - Wall mirror, overall size 476 x 855mm height

nr

SAN-BOH-108 - Janitor's basin

nr

Pool Changing Rooms


Refer to 'Provisional Sums' section
Guest room Toilets
Supply and installation of bathroom fixture and accessories to Guest
room areas including all fittings, short pipe connections, supports, joints,
fixing and accessories, complete; all in accordance with the Drawings
and Specification Section 102800 and 224000
King room (52nr)
E

SAN-GR-101 - Wall hung water closet

51

nr

SAN-GR-104 - Shower head

51

nr

SAN-GR-102 - Under counter basin

51

nr

SAN-GR-103 - Basin faucet

52

nr

SAN-GR-105 - Shower head - wall mounted

52

nr

SAN-GR-106 - Shower mixer

52

nr

SAN-GR-109 - Ablution hose

52

nr

SAN-GR-110 - Floor drain

52

nr

SAN-GR-111 - Shower drain (**)

52

nr

SAN-GR-201 - Wall hung water closet

nr

SAN-GR-202 - Lavatory

nr

SAN-GR-203 - Faucet with mixer

nr

SAN-GR-204 - Vertical grab rail

nr

SAN-GR-205 - Horizontal grab rail

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-GR-206 - Swing up grab rail

nr

SAN-GR-207 - L shape grab rail

nr

SAN-GR-120 - Toilet paper holder

52

nr

SAN-GR-123 - Robe hook

208

nr

SAN-GR-124 - Water closet brush set

52

nr

SAN-GR-125 - Magnifying wall mirror, overall size 180mm diameter

51

nr

SAN-GR-310 - Wall mirror, overall size 476 x 855mm height

nr

SAN GR-208; Seat

nr

new

Double room (22nr)


H

SAN-GR-101 - Wall hung water closet

22

nr

SAN-GR-102 - Under counter basin

22

nr

SAN-GR-103 - Basin Faucet

22

nr

SAN-GR-107 - Bathtub set (**)

22

nr

SAN-GR-108 - Bathtub faucet (**)

22

nr

SAN-GR-109 - Ablution hose

22

nr

SAN-GR-110 - Floor drain

22

nr

SAN-GR-120 - Toilet paper holder

22

nr

SAN-GR-123 - Robe hook

88

nr

SAN-GR-124 - Water closet brush set

22

nr

SAN-GR-125 - Magnifying wall mirror, overall size 180mm diameter

22

nr

Suite room (6nr)


U

SAN-GR-101 - Wall hung water closet

13

nr

SAN-GR-104 - Shower head

13

nr

SAN-GR-102 - Under counter basin

13

nr

SAN-GR-103 - Basin Faucet

nr

SAN-GR-105 - Shower head - wall mounted

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-GR-106 - Shower mixer

nr

SAN-GR-107 - Bathtub set (**)

nr

SAN-GR-108 - Bathtub faucet (**)

nr

SAN-GR-109 - Ablution hose

13

nr

SAN-GR-110 - Floor drain

13

nr

SAN-GR-111 - Shower drain (**)

nr

SAN-GR-120 - Toilet paper holder

13

nr

SAN-GR-123 - Robe hook

28

nr

SAN-GR-124 - Water closet brush set

13

nr

SAN-GR-125 - Magnifying wall mirror, overall size 180mm diameter

nr

VIP room (1nr)


L

SAN-VP-101 - Wall hung water closet

nr

SAN-VP-102 - Under counter basin

nr

SAN-VP-103 - Basin faucet

nr

SAN-VP-104 - Shower head

nr

SAN-VP-105 - Hand shower

nr

SAN-VP-106 - Shower mixer

nr

SAN-VP-107 - Bathtub set (**)

nr

SAN-VP-108 - Bathtub faucet (**)

nr

SAN-VP-109 - Ablution hose

nr

SAN-VP-110 - Floor drain

nr

SAN-VP-111 - Shower drain (**)

nr

SAN-VP-120 - Toilet paper holder

nr

SAN-VP-123 - Robe hook

nr

SAN-VP-124 - Water closet brush set

nr

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-VP-125 - Magnifying wall mirror, overall size 180mm diameter


Apartment Toilets
Supply and installation of bathroom fixture and accessories to apartment
areas including all fittings, short pipe connections, supports, joints, fixing
and accessories, complete; all in accordance with the Drawings and
Specification Section 102800 and 224000
One bedroom apartment (108nr)

SAN-AP-101 - Wall hung water closet

211

nr

SAN-AP-102 - Under counter basin

211

nr

SAN-AP-103 - Basin faucet

211

nr

SAN-AP-104 - Shower head

108

nr

SAN-AP-105 - Hand shower

108

nr

SAN-AP-106 - Shower mixer

108

nr

SAN-AP-109 - Ablution hose

212

nr

SAN-AP-110 - Floor drain

334

nr

SAN-AP-111 - Shower drain (**)

108

nr

SAN-AP-201 - Wall hung water closet

nr

SAN-AP-202 - Lavatory

nr

SAN-AP-203 - Faucet with mixer

nr

SAN-AP-204 - Vertical grab rail

nr

SAN-AP-206 - Swing up grab rail

nr

SAN-AP-207 - L shape grab rail

nr

SAN-AP-208 - Seat

nr

SAN-AP-301 - Toilet paper holder

212

nr

SAN-AP-304 - Robe hook

432

nr

SAN-AP-305 - Water closet brush set

212

nr

108

nr

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-AP-306 - Magnifying wall mirror, overall size 180mm diameter

SAN-AP-310 - Wall mirror, overall size 476 x 855mm height


Two bed room apartment (22nr)

SAN-AP-101 - Wall hung water closet

62

nr

SAN-AP-102 - Under counter basin

62

nr

SAN-AP-103 - Basin faucet

62

nr

SAN-AP-104 - Shower head

23

nr

SAN-AP-105 - Hand shower

23

nr

SAN-AP-106 - Shower mixer

23

nr

SAN-AP-107 - Bathtub set (**)

27

nr

SAN-AP-108 - Bathtub faucet (**)

27

nr

SAN-AP-109 - Ablution hose

63

nr

SAN-AP-110 - Floor drain

101

nr

SAN-AP-111 - Shower drain (**)

23

nr

SAN-AP-201 - Wall hung water closet

nr

SAN-AP-202 - Lavatory

nr

SAN-AP-203 - Faucet with mixer

nr

SAN-AP-204 - Vertical grab rail

nr

SAN-AP-206 - Swing up grab rail

nr

SAN-AP-207 - L shape grab rail

nr

SAN-AP-208 - Seat

nr

SAN-AP-301 - Toilet paper holder

63

nr

SAN-AP-304 - Robe hook

164

nr

SAN-AP-305 - Wc brush set

63

nr

SAN-AP-306 - Magnifying wall mirror, overall size 180mm diameter

22

nr

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-AP-310 - Wall mirror, overall size 476 x 855mm height


Three bedroom apartment (10nr)

SAN-AP-101 - Wall hung water closet

34

nr

SAN-AP-102 - Under counter basin

40

nr

SAN-AP-103 - Basin Faucet

40

nr

SAN-AP-104 - Shower head

15

nr

SAN-AP-105 - Hand shower

15

nr

SAN-AP-106 - Shower mixer

15

nr

SAN-AP-107 - Bathtub set (**)

11

nr

SAN-AP-108 - Bathtub faucet (**)

11

nr

SAN-AP-109 - Ablution hose

44

nr

SAN-AP-110 - Floor drain

71

nr

SAN-AP-111 - Shower drain (**)

15

nr

SAN-AP-221 - Water closet with cistern

10

nr

SAN-AP-222 - Lavatory

10

nr

SAN-AP-223 - Lavatory mixer

10

nr

SAN-AP-301 - Toilet paper holder

44

nr

SAN-AP-304 - Robe hook

136

nr

SAN-AP-305 - Wc brush set

44

nr

SAN-AP-306 - Magnifying wall mirror, overall size 180mm diameter

10

nr

SAN-AP-311 - Wall mirror / Medicine cabinet, overall size 476 x 855mm


height

10

nr

SAN-AP-312 - Shower rod

nr

SAN-AP-313 - Shower curtain

nr

SAN-AP-314 - Shower rod

nr

nr

Items Part of Value Engineering (**)


Carried to Collection
A

SAN-AP-315 - Shower curtain


Back of House Toilets
Supply and installation of bathroom fixture and accessories to back of
house areas including all fittings, short pipe connections, supports, joints,
fixing and accessories, complete; all in accordance with the Drawings
and Specification Section 102800 and 224000

SAN-AP-105 - Hand shower

nr

SAN-AP-106 - Shower mixer

nr

SAN-AP-109 - Ablution hose

nr

SAN-AP-110 - Floor drain

nr

SAN-AP-111 - Shower drain (**)

nr

SAN-AP-221 - Toilet with tank

nr

SAN-AP-222 - Lavatory

15

nr

SAN-AP-223 - Faucet

15

nr

SAN-AP-301 - Toilet paper holder

nr

SAN-AP-305 - Water closet brush set

nr

SAN-AP-311 - Wall mirror, overall size 476 x 855mm height

15

nr

Items Part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.1
5A: SANITARY APPLIANCES
COLLECTION
Page No

Total Brought Forward from Page No.

-153-154-155-156-157-158-159-160-161-

Carried Forward to Summary of Section No. 6

5C: DISPOSAL INSTALLATIONS


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

RAIN WATER DRAIN

Pipework
Supply and installation off uPVC rain water drainage pipe work with
acoustic lagging insulation including all necessary accessories, fittings,
supports, labelling and the like; complete; all in accordance with the
Drawings and Specification Section 503.2400
A

50mm diameter

818

75mm diameter

175

100mm diameter

533

150mm diameter

760

200mm diameter

553

250mm diameter

108

156

Supply and installation off uPVC rain water drainage pipe work including
all necessary accessories, fittings, supports, labelling and the like;
complete; all in accordance with the Drawings and Specification Section
503.24
Vertical/ Riser distribution
G

150mm diameter
Supply and installation of rain water drainage ancillaries, including all
necessary joints, fittings, supports, fixings and accessories, complete; all
in accordance with the Drawings and Specification Section 503.2400

Rain water outlet,100mm diameter

22

nr

Rain water outlet,150mm diameter

20

nr

Rodding eye, 75mm diameter

nr

Rodding eye, 100mm diameter

55

nr

Carried to Collection
A

Rodding eye, 150mm diameter

67

nr

Rodding eye, 200mm diameter

nr

Rodding eye, 250mm diameter

nr

CONDENSATE DRAIN
Air conditioning and refrigeration system condensate drain
Supply and install uPVC condensate drainage pipes for air conditioning
and refrigeration equipment, including all necessary fittings, fixtures,
joints, insulation, brackets, supports, labelling and the like; complete; all
in accordance with the Drawings and Specification Section 503.2300
D

25mm diameter

3,030

32mm diameter

456

50mm diameter

758

75mm diameter

15

100mm diameter

747

Supply and installation of closed cell elastometric foam insulation to


condensate drainage pipe works including all necessary joints, fittings,
supports, fixings and accessories, complete; all in accordance with the
Drawings and Specification Section 560.0205
J

25mm diameter

3,030

32mm diameter

456

50mm diameter

758

75mm diameter

15

100mm diameter

747

Supply and installation of condensate drainage ancillaries, including all


necessary joints, fittings, supports, fixings and accessories, complete; all
in accordance with the Drawings and Specification Section 503.2400
P

Rodding eye, 25mm diameter

231

nr

Rodding eye, 32mm diameter

21

nr

Rodding eye, 50mm diameter

11

nr

Carried to Collection
A

Rodding eye, 100mm diameter

15

nr

Rodding eye, 250mm diameter

nr

MAIN DRAINAGE SYSTEM


Soil Waste and Vent pipe work
Supply and installation of uPVC soil, waste and vent drainage pipe work
with acoustic lagging insulation including all necessary accessories,
fittings, supports, labelling and the like; complete; all in accordance with
the Drawings and Specification Section 503.2300
C

50mm diameter

2,715

75mm diameter

405

100mm diameter

5,750

150mm diameter

3,819

200mm diameter

558

Supply and installation of uPVC soil, waste and vent drainage pipe work
including all necessary accessories, fittings, supports, labelling and the
like; complete; all in accordance with the Drawings and Specification
Section 503.2300
Vertical/ Riser distribution
H

100mm diameter

1,873

150mm diameter

85

Pump drain pipe (PDP)


Supply and installation of HDPE pressurised drainage waste and soil
water pipe work including all necessary accessories, fittings, supports,
labelling and the like, complete; all in accordance with the Drawings and
Specification Section 503.2300
K

32mm diameter

230

40mm diameter

24

75mm diameter

350

100mm diameter

447

Carried to Collection

150mm diameter

259

Kitchen waste pipe (KWP)


Supply and installation of HDPE kitchen waste drainage pipe work
including all necessary accessories, fittings, supports, labelling and the
like, complete; all in accordance with the Drawings and Specification
Section 503.2300
B

50mm diameter

67

75mm diameter

56

100mm diameter

93

150mm diameter

169

200mm diameter

34

Sanitary installations
Supply and installation of drainage ancillaries including all necessary
fittings, supports, joints, fixings and accessories, complete; all in
accordance with the Drawings and Specification Section 503.2300 &
Section 503.2400
G

Flow drain

11

nr

Balcony drain

194

nr

Planter drain

26

nr

Water tank drain

16

nr

Catch basin (CB)

27

nr

Floor trap with cover

293

nr

Floor sink waste drain (FT), 110mm diameter

38

nr

Funnel drain (FD), 100mm diameter

nr

Gate valve, 100mm diameter

nr

Non return valve, 32mm diameter

nr

Vent cowl, 100mm diameter

231

nr

Rodding eye, 50mm diameter

nr

Carried to Collection
A

Rodding eye, 75mm diameter

nr

Rodding eye, 100mm diameter

35

nr

Rodding eye, 150mm diameter

81

nr

Rodding eye, 200mm diameter

nr

Floor cleanout (FCO), 100mm diameter

25

nr

Trench drain channel with heavy duty grating, 300 x 300mm depth

62

Supply and installation of manholes and gully trap including all necessary
excavation, disposal, backfilling, waterproofing, reinforced concrete
bases and walls, heavy duty frames and covers, fixings and accessories,
complete; all in accordance with the Drawings and Specification Section
503.2300 & Section 503.2400
G

Grease trap

nr

Oil interceptor

nr

Sealed gully trap

nr

Laundry lint interceptor, 70 gpm capacity

nr

Sump pit, size 1200 x 1200 x 1200mm (**)

nr

Sump pit, size 3000 x 3000 x 3000mm (**)

nr

Sump pit, size 5000 x 5000 x 3000mm (**)

nr

Sump pit, size 600 x 600 x 700mm (**)

nr

Storm water sewer manhole ref. SWMH- 9, SWMH- 10 & SWMH- 31 size
600 x 600mm with ductile iron heavy duty cover

nr

Storm water sewer manhole ref. SWMH- 1, SWMH- 2.SWMH-4 &


SWMH- 5 size 600 x 600mm with ductile iron heavy duty cover

nr

Foul water sewer manhole ref. FWMH - 12, FWMH- 15 & FWMH- 16 size
600 x 600mm with ductile iron heavy duty cover

nr

Foul water sewer manhole ref. FWMH- 19 & FWMH- 19A size 600 x
600mm with ductile iron heavy duty cover

nr

Foul water sewer manhole ref. FWMH - 22, FWMH- 24, FWMH- 26
FWMH -28 & FWMH -30 , size 600 x 600mm with ductile iron heavy duty
cover

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

Foul water sewer manhole ref. FWMH - 12, FWMH- 15 & FWMH- 16 size
600 x 600mm with ductile iron heavy duty cover

nr

Wastewater sewer manhole ref. WWMH - 11 & WWMH- 13 size 600 x


600mm with ductile iron heavy duty cover

nr

Wastewater sewer manhole ref. WWMH - 17 & WWMH- 18 size 600 x


600mm with ductile iron heavy duty cover

nr

Wastewater sewer manhole ref. WWMH - 20 & WWMH- 20A size 600 x
600mm with ductile iron heavy duty cover

nr

Wastewater sewer manhole ref. WWMH - 21, WWMH- 23, WWMH- 26


WWMH -27 & WWMH -29 , size 600 x 600mm with ductile iron heavy
duty cover

nr

Equipment
Supply and installation of sump pit pumps, including all control panels,
valves, gauges, switches, connections, pipes, wiring, supports, bases
and connection to power supply, complete; all in accordance with the
Drawings and Specification Section 503.2300 & Sectioj 503.2400
F

Foul water lifting station pump set - 1, 5 lps at 25.0 m head ref. SP 01,02 & 03 ( 2 duty + 1 stand by) sized reduced (**)

Sets

Foul water lifting station pump set - 2, 6. 5 lps at 25.0 m head ref. SP 04,05 & 06 ( 2 duty + 1 stand by) size reduced (**)

Sets

Foul water lifting station pump set - 3, 7.5 lps at 25.0 m head ref. SP 07,08 & 09 ( 2 duty + 1 stand by) size reduce (**)

Sets

Foul water lifting station pump set - 4, 7.5 lps at 25.0 m head ref. SP 10,11 & 12 ( 2 duty + 1 stand by)

Sets

Storm drainage lifting station- 1, 6.5 lps at 25.0m head ref. SP - 26,27 &
28 ( 2 duty + 1 stand by)

Sets

Storm drainage lifting station- 2, 3.5 lps at 25.0m head ref. SP - 29,30 &
31 ( 2 duty + 1 stand by)

Sets

Lift sump pump - 1 to 6, 0.51 lps at 15.0m head ref. SP - 32 ot SP - 37 size reduce (**)

nr

Items as Part of Value Engineering (**)


Carried to Collection
Supply and installation of sewerage lifting pumps, including all control
panels, valves, gauges, switches, connections, pipes, wiring, supports,
bases and connection to power supply, complete; all in accordance with
the Drawings and Specification Section 503.2300
A

Waste lifting station pump set -1, 5 lps at 25.0m head ref. SP - 13 & 14 (
1 duty + 1 stand by )

Sets

Waste lifting station pump set -2, 3.5 lps at 25.0m head ref. SP - 15,16 &
17 ( 2 duty + 1 stand by )

Sets

Waste lifting station pump set -3, 4 lps at 25.0m head ref. SP - 18.19 &
20 ( 2 duty + 1 stand by )

Sets

Waste lifting station pump set -4, 6 lps at 25.0m head ref. SP - 21,22 &
23 ( 2 duty + 1 stand by )

Sets

Waste lifting station pump set -5, 3 lps at 15.0m head ref. SP - 21,22 &
23 ( 2 duty + 1 stand by )

Sets

Items as Part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.3
5C: DISPOSAL INSTALLATIONS
COLLECTION
Page No
Total Brought Forward from Page No.

-207-208-209-210-211-212-213-

Items as Part of Value Engineering (**)


Carried Forward to Summary of Section No. 6

5D: WATER INSTALLATIONS


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

WATER SUPPLY SERVICES


Pipe work
Main incoming water line
Supply and installation of uPVC pipe work, including all necessary
supports, markings, fire stops, flexible joints, consumables and the like,
complete; all in accordance with the Drawings and Specification Section
503.2
A

100mm diameter

95

327

Make up water Pipe work


B

100mm diameter
Supply and installation of polypropylene (PPR) Pipe work, including all
necessary supports, markings, fire stops, flexible joints, consumables
and the like, complete; all in accordance with the Drawings and
Specification
Internal cold water supply (CWS) Pipe work

15mm diameter

480

20mm diameter

886

25mm diameter

685

32mm diameters

169

40mm diameter

229

50mm diameter

284

65mm diameters

187

100mm diameter

349

Items as Part of Value Engineering (**)


Carried to Collection
Internal cooled cold water supply (CCWS) Pipe work
A

15mm diameter

3,224

20mm diameter

4,419

25mm diameter

989

32mm diameters

1,042

40mm diameter

719

50mm diameter

209

65mm diameters

161

75mm diameter

327

Internal softened cold water supply (SCWS) Pipe work


J

25mm diameter

32mm diameters

141

50mm diameter

256

Internal grey water supply (GWS) Pipe work


M

15mm diameter

1,556

20mm diameter

544

25mm diameter

1,916

32mm diameters

951

40mm diameter

785

50mm diameter

593

65mm diameters

237

75mm diameter

140

100mm diameter

149

2,227

Internal hot water supply (HWS) Pipe work


W

15mm diameter
Items as Part of Value Engineering (**)
Carried to Collection

20mm diameter

2,751

25mm diameter

551

32mm diameters

1,554

40mm diameter

374

50mm diameter

703

65mm diameters

223

75mm diameter

313

Internal hot water supply (HWR) Pipe work


H

15mm diameter

1,975

20mm diameter

2,456

25mm diameter

1,735

32mm diameters

432

40mm diameter

167

50mm diameter

427

Supply and installation of polypropylene Pipe work (PEX ) withtin wall


vertical drop, including all necessary supports, marking, fire stops,
flexible joints, consumables, and the like, complete, all in accordance with

the Drawings and Specification Section 503.2000 & Secition 503.2100


Internal cold water supply (CWS) Pipe work
P

12mm diameter

148

15mm diameter

162

20mm diameter

31

25mm diameter

14

3,307

1,095

Internal cooled cold water supply (CCWS) pipe work


T

15mm diameter

Items as Part of Value Engineering (**)


Carried to Collection
Internal grey water supply (GWS) pipe work
A

15mm diameter
Internal hot water supply (HWS) pipe work

12mm diameter

137

15mm diameter

1,957

20mm diameter

50

Supply and installation of closed cell elastometric foam insulation for cold
and grey water pipe work, complete; all in accordance with the Drawings
and Specification Section 560.0205
E

15mm diameter

5,260

20mm diameter

5,858

25mm diameter

3,731

32mm diameter

2,162

40mm diameter

1,733

50mm diameter

1,342

65mm diameter

585

75mm diameter

467

110mm diameter

850

Supply and installation of closed cell elastometric foam insulation for hot
water pipe work, complete; all in accordance with the Drawings and
Specification Section 560.0205
P

15mm diameter

4,202

20mm diameter

5,209

25mm diameter

2,286

32mm diameter

1,986

40mm diameter

541

50mm diameter
Items as Part of Value Engineering (**)

1,130

Carried to Collection
A

65mm diameter

223

75mm diameter

313

Water pipe work specialties


Supply and installation of the final cold / hot water connections to the
sanitary appliances inside the building, including supports, fittings,
markings, flexible joints, consumables and the like, complete; all in
accordance with the Drawings and Specification Section 503.2000 &
Section 503.2100
Internal cold water supply pipe work
C

12mm diameter pipes for final cold water connection

53

nr

15mm diameter pipes for final cold water connection

65

nr

20mm diameter pipes for final cold water connection

11

nr

25mm diameter pipes for final cold water connection

nr

1,330

nr

Internal cooled cold water supply pipe work


G

15mm diameter pipes for final cold water connection

Internal grey water supply pipe work


H

15mm diameter pipes for final cold water connection

411

nr

Internal hot water supply pipe work


J

12mm diameter pipes for final hot water connection

49

nr

15mm diameter pipes for final hot water connection

783

nr

20mm diameter pipes for final hot water connection

20

nr

Items as Part of Value Engineering (**)


Carried to Collection
Water pipe work specialties
Supply and installation of hot and cold water pipe specialties; including all
related fixing materials, complete; all in accordance with the Drawings
and Specification Section 503.2000 & Sectiion 503.2100
Isolation valve (IV)
A

15mm diameter

996

nr

20mm diameter

215

nr

25mm diameter

658

nr

32mm diameter

470

nr

40mm diameter

nr

50mm diameter

nr

75mm diameter

nr

100mm diameter

nr

Pressure reducing valve (PRV)


J

50mm diameter

nr

65mm diameter

nr

75mm diameter

nr

Non Return Valves


M

100mm diameter

nr

1,525

nr

Water hammer arrestor


N

Water hammer arrestors connected to pipes qty reduce to 458 (**)


Double regulating valve (DRV)

20mm diameter

74

nr

25mm diameter

179

nr

32mm diameter

nr

50mm diameter
Items as Part of Value Engineering (**)

nr

Carried to Collection
Check valve
A

20mm diameter

74

nr

25mm diameter

179

nr

856

nr

nr

Three port control valve


C

20mm diameter qty reduce 257 (**)


Double regulating/ balancing valve

80mm diameter
Digital recirculating valve (DRCV)

50mm diameter

nr

75mm diameter

nr

100mm diameter

nr

Automatic air vent (AAV)


H

25mm diameter

nr

32mm diameter

68

nr

40mm diameter

84

nr

50mm diameter

nr

52

nr

Bibtap c/w lock shield valve & integral double check valve
M

20mm diameter
Equipment
Supply and installation of sub- water meter including all necessary
fittings, shut off valves, supports, joints, fixings and accessories and
connections, complete; all in accordance with the Drawings and
Specification Section 530.2000

25mm diameter

nr

32mm diameter

nr

40mm diameter

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

50mm diameter

nr

65mm diameter

nr

75mm diameter

nr

100mm diameter

nr

150mm diameter

nr

nr

Supply and installation of pressure vessels, including fittings and


connections, complete; all in accordance with the Drawings and
Specification
F

Pressure vessel to booster pumps


Supply and installation of hot water calorifiers including valves, gauges,
fittings, supports, joints, fixings and accessories and connections,
complete; all in accordance with the Drawings and Specification

Gas fired hot water calorifier. 5000 liters capacity at 350 kw

nr

Expansion vessel , 1000 liters capacity

nr

Supply and installation of plate heat exchanger, including fittings and

connections, complete; all in accordance with the Drawings and


Specification
J

Plate heat exchanger, double wall type

nr

item

nr

nr

102

nr

Supply and installation of break tank and pump assembly including


fittings and connections, complete; all in accordance with the Drawings
and Specification
K

Break tank and pump assembly, 1m3 tank capacity


Supply and installation of plate heat exchanger, including fittings and
connections, complete; all in accordance with the Drawings and
Specification

Plate heat exchanger, 252 kw capacity

Items as Part of Value Engineering (**)


Carried to Collection
Solar Hot Water Generation System
Note; The work is to be done by a specialist contractor
Supply and installation of solar hot water generation system including
insulation, vessels, pumps, fittings, supports, joints, fixings and
accessories and connections, complete; all in accordance with the
Drawings and Specification Section 503.4800.
A

Hot water storage tank, 30,000 liters capacity

Solar collector panels.2.4m2

Plate heat exchanger - 1

nr

Access heat dissipation unit

item

Expansion vessel

nr

Chemical less electronic water treatment system

item

Supply and installation of thermostatic mixing valve, piping, valves,

item

gauges and fittings, complete


H

Solar software panel, complete

item

Solar system circulation pump set, capacity 0.83 lps (1 duty + 1


stand-by)

Set

Solar control system and various sensors

item

item

Sets

Water Treatment System


Note: The work is to be done by a specialist contractor

Items as Part of Value Engineering (**)


Carried to Collection
Grey Water Treatment Plant
Note: The work is to be done by a specialist contractor
A

Supply and installation of grey water treatment plant including


chlorination system, disinfection system, filter/ backwash system, filtration
system, pumps, chemical tanks and vessels, valves, gauges, pipe works,
control panels, final electrical connections, meters and fixing , complete;
all in accordance wuth the Drawings and Specifications Section 503.5100
Supply and installation of pumps, including all necessary control panels,
gauges, valves, strainers, air vents, flexible connections, pipes, wiring,
hangers, supports bases and connection to power supply for the proper
operation of the system, complete; all in accordance with the Drawings
and Specification Section 530.2000 & Section 503.2100

Filtered CWS booster pump set with VFD motor, 12.5 lps at 35.0m head
ref. FWTP- 01 & 02, (1 duty & 1 standby);

Softened CWS kitchen booster pump set with VFD motor, 12.5 lps at
35.0m head ref. SWTP - 01 7 02, (1 duty & 1 standby);

Sets

Hot water circulation pump set with VFD motor, ref. HWCP - 01 & 02 for
solar system, (1 duty & 1 standby);

Sets

Cooled cold water booster pump set with VFD motor, 6.0 lps at 65.0m
head ref. CCWBP - 01,02,03 & 04 (3 duty & 1 standby);

Sets

GWS transfer feed pump set, 30 lps at 30.0m head ref. GWFP - 01 & 02,
( 1 duty + 1 stand by )

Sets

Treated grey water supply booster pump set with VFD motor 7.0 lps at
60.0m head ref. TGWBP- 01,02 7 03, (2 duty & 1 standby);

Sets

Softened CWS transfer pump set, 5.0lps at 55.0m head ref. SWBP - 01
& 02, (1 duty + 1 stand by )

Sets

Hot water circulation pump set ,5.2 lps at 40.0m head ref. HWRP - 01 &
02 (1 duty + 1stand by)

Sets

Hot water circulation pump set ,5.0 lps at 40.0m head ref. HWRP - 04 &
03 (1 duty + 1stand by)

Sets

Hot water circulation pump set ,4.0 lps at 35.0m head ref. HWRP - 05&
06 (1 duty + 1stand by)

Sets

Items as Part of Value Engineering (**)


Carried to Collection
A

Cooled cold water circulation pump set ,10 lps at 30.0m head ref.CCWCP
- 01 & 02, ( 1 duty + 1 stand by )

Sets

Cooling tower Make up water pump set;2.5 lps at 30.0m head ref. MWP 01,02 & 03 (2 duty + 1 stand by)

Sets

Extra over connection


C

Allow for domestic water cooling system connected to the chilled water
supply network complete; all in accordance with the Drawings and
Specification Section 503.2000

item

Allow for portable water pipe work connected to the external main water
supply network including valves, valve chamber, supports and
accessories, complete; all in accordance with the Drawings and
Specification Section 503.2000 (**)

item

Allow for irrigation/ make up water pipe work connected to the external
main water supply network including valves, valve chamber, supports

item

and accessories, complete; all in accordance with the Drawings and


Specification Section 503.2000 (**)

Items as Part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.4
5D: WATER INSTALLATIONS
COLLECTION
Page No
Total Brought Forward from Page No.

-215-216-

-217-218-219-220-221-222-223-224-225-

Items as Part of Value Engineering (**)


Carried Forward to Summary of Section No. 6

5F: SPACE HEATING AND AIR TREATMENT


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

AIR-CONDITIONING AND VENTILATION SERVICES


Pipe work
Supply and installation of black steel EWR schedule 40 chilled water

Pipe work including all supports, pipe fittings, labelling, marking, cuttings,
mortices, chases, protective painting, and the like, complete; all in
accordance with the Drawing and Specification.Section 503.0200
A

20mm diameter

5,889

25mm diameter

1,468

32mm diameter

420

40mm diameter

647

50mm diameter

866

65mm diameter

696

80mm diameter

430

100mm diameter

308

150mm diameter

567

200mm diameter

162

250mm diameter

207

Pipe work Insulation


Supply and installation of closed cell elastometric foam insulation to
chilled water pipes insulation, including adhesives, straps. complete; all in
accordance with the Drawings and Specification Section 560.0205
M

20mm diameter

5,737

25mm diameter

1,447

Items as Part of Value Engineering (**)


Carried to Collection
A

32mm diameter

366

40mm diameter

647

50mm diameter

633

65mm diameter

614

100mm diameter

225

Supply and installation of closed cell elastometric fan insulation with


aluminium cladding to chilled water external of the building exposed to
weather , identifications, marking, cutting, chases, complete; all in
accordance with the Drawings and Specification Section 560.0205
F

20mm diameter

152

25mm diameter

21

32mm diameter

54

50mm diameter

233

65mm diameter

82

100mm diameter

75

150mm diameter

47

200mm diameter

162

250mm diameter

207

Extra over special connections


Q

Allow for the chilled water system flushing and passivation including
valves, fittings, chemicals for water flushing, associated tools and
equipments as neccessary, pipes , complete

item

Allow for connection to the makeup water line including all necessary
fittings and accessories, etc. complete as per the Drawings and
Specifications.

item

Allow for connection to the heat exchanger including all necessary fittings
and accessories, etc. complete as per the drawings and specifications.

item

Items as Part of Value Engineering (**)


Carried to Collection
Chilled water pipe accessories
Supply and installation of chilled water Pipe work accessories, including
all necessary insulation, supports, joints, fixings, fittings and accessories,
complete; all in accordance with the Drawings and Specification Section
530.03

Isolating valve
A

20mm diameter

1,178

nr

25mm diameter

24

nr

32mm diameter

nr

40mm diameter

nr

50mm diameter

18

nr

65mm diameter

14

nr

200mm diameter

24

nr

Pressure independent control valve (PICV)


H

20mm diameter

589

nr

25mm diameter

12

nr

32mm diameter

nr

40mm diameter

nr

50mm diameter

nr

65mm diameter

nr

12

nr

12

nr

589

nr

Globe valve (GB)


P

200mm diameter
Non return valve

200mm diameter
Strainer

20mm diameter
Items as Part of Value Engineering (**)
Carried to Collection

25mm diameter

12

nr

32mm diameter

nr

40mm diameter

nr

50mm diameter

nr

65mm diameter

nr

200mm diameter

12

nr

12

nr

Relief valve
G

25mm diameter
Test point

20mm diameter

1,178

nr

25mm diameter

24

nr

32mm diameter

nr

40mm diameter

nr

50mm diameter

18

nr

65mm diameter

14

nr

200mm diameter

24

nr

Drain cock
Q

20mm diameter

589

nr

25mm diameter

12

nr

32mm diameter

nr

40mm diameter

nr

50mm diameter

nr

65mm diameter

nr

19

nr

Temperature gauge
W

Temperature gauge connected to chilled water pipes


Items as Part of Value Engineering (**)
Carried to Collection
Pressure gauge

Pressure gauge connected to chilled water pipes

24

nr

Flexible connector
B

20mm diameter

1,179

nr

25mm diameter

24

nr

32mm diameter

nr

40mm diameter

nr

50mm diameter

18

nr

65mm diameter

14

nr

200mm diameter

24

nr

Ductwork
Supply and installation of galvanized steel ductwork including all fittings,
joints, supports, hangers, stiffeners, blank ends, bell mouths, protective
coatings, accessories and acoustic lining, complete; all in accordance
with the Drawings and Specification Section 520.0200
J

Supply air (SAD)

37,861

kg

Fresh air (FAD)

36,511

kg

Return air (RAD)

7,218

kg

Extract air duct (EAD)

9,431

kg

Kitchen extract duct (KEAD), Guestrooms

3,393

kg

Make up air (KMAD)

5,816

kg

Stair pressurization duct (SPD)

3,956

kg

Lift pressurization duct (LPD)

872

kg

Carpark fresh air (CPFAD)

1,341

kg

Items as Part of Value Engineering (**)

Carried to Collection
Supply and installation of fire rated galvanized steel ductwork including
all fittings, joints, supports, hangers, stiffeners, blank ends, bell mouths,
protective coatings, accessories and acoustic lining, complete; all in
accordance with the Drawings and Specification Section 520.0900
A

Smoke extract duct (SEAD)

2,282

kg

Carpark extract duct (CPED)

2,798

kg

Kitchen extract duct (KEAD), Restaurant & All Day Dining (**)

6,803

kg

Extra over connection


Supply and installation of flexible duct and plenium box with acoustic
lined connections to air outlets including fittings and accessories,
complete;all in accordance with the Drawings and Specification.Section
503.18
D

Flexible duct - 150mm diameter

23

Flexible duct - 200mm diameter

324

Flexible duct - 250mm diameter

36

Flexible duct - 300mm diameter

21

Plenum box - 1000 x 300 x 350mm H

231

nr

Plenum box - 1050 x 300 x 350mm H

38

nr

Plenum box - 18000 x 1000 x 400mm H

nr

Plenum box - 10000 x 1000 x 1500mm H

nr

Supply and installation of closed cell elastometric foam insulation to


ductwork, including adhesives, test holes, fasteners, anchors, finishes,
identification markings, access panels, and all related fixing accessories,
complete; all in accordance with the Drawings and Specification Section
560.03
M

Supply air (SAD)

5,480

m2

Fresh air (FAD)

3,310

m2

Return air (RAD)

456

m2

Extract air duct (EAD)

2,054

m2

Kitchen extract duct (KEAD), Guestrooms


Items as Part of Value Engineering (**)

896

m2

Carried to Collection
A

Kitchen extract duct (KEAD), Restaurant & All Day Dining

659

m2

Make up air (KMAD)

512

m2

Smoke extract duct (SEAD)

220

m2

Carpark extract duct (CPED)

345

m2

Carpark fresh air (CPFAD)

166

m2

619

m2

Supply and installation of closed cell elastometric foam insulation with


aluminium cladding to ductwork external to building exposed to weather
including adhesives, test holes, fasteners, anchors, finishes, identification
markings, access panels, and all related fixing accessories, complete; all
in accordance with the Drawings and Specification Section 560.0305
F

Supply air (SAD)

Fresh air (FAD)

2,712

m2

Return air (RAD)

574

m2

Extract air duct (EAD)

745

m2

Kitchen extract duct (KEAD), Guestrooms

973

m2

Kitchen extract duct (KEAD), Restaurant

219

m2

Make up air (KMAD)

276

m2

Smoke extract duct (SEAD)

62

m2

Stair pressurization duct (SPD)

378

m2

Lift pressurization duct (LPD)

108

m2

15

nr

Equipment
Supply and installation of air fans including all controls, supports,
accessories, mountings, vibration isolator and electrical connection from
isolator to the unit, complete; all in accordance with the Drawings and
Specification Section 503.1500
R

Car park impulse fan ref. IF-01 to IF-15, 2450 lps

Over head blower

nr

TR-EF-01, 5785 lps

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

TR-EF-02, 5785 lps

nr

CPEF-01, 9100 lps

nr

CPEF-02, 9100 lps

nr

CPEF-03, 9100 lps

nr

CPEF-04, 10200 lps

nr

CPEF-05, 10200 lps

nr

CPEF-06, 10200 lps

nr

CPSF-01, 14130 lps

nr

CPSF-02, 14130 lps

nr

CPSF-03, 14130 lps

nr

A -SEF-01, 18050 lps

nr

A-SEF-02, 18050 LPS

nr

LPF-01, 9655 lps

nr

LPF-02, 9655 lps

nr

LPF-03, 9655 lps

nr

LPF-04, 9655 lps

nr

LPF-05, 4512 lps

nr

LPF-06, 4512 lps

nr

SPF-01, 14430 lps

nr

SPF-02, 14430 lps

nr

SPF-03, 14430 lps

nr

SPF-04, 14430 lps

nr

SPF-05, 14430 lps

nr

SPF-06, 14430 lps

nr

AA

SPF-07, 14430 lps


Items as Part of Value Engineering (**)

nr

Carried to Collection
A

GFAF- 8- 01, 16900 lps

nr

GFAF- 8- 02, 16900 lps

nr

GEAF- 8- 01, 15350 lps

nr

GEAF- 8- 02, 15350 lps

nr

FPEAF- B- 01, 6350 lps

nr

FPEAF- B- 02, 6350 lps

nr

KEF -01, 3315 lps

nr

LEF - 01, 1400 lps

nr

Supply and installation of water- cooled chiller with screw compressor


including all necessary accessories, gauges, Pipe work, fittings, control
and monitoring cabling, supports, fixings and associated equipment;
complete; all in accordance with the Drawings and Specification Section
503.07
J

CHILLER-01, 1853 kw 63.0 lps flow rate

nr

CHILLER-02, 1853 kw 63.0 lps flow rate

nr

CHILLER-03, 1853 kw 63.0 lps flow rate

nr

Supply and installation of cooling towers including all necessary


accessories, Pipe work, fittings, control and monitoring cabling, supports,
fixings and associated equipment; testing and commissioning, complete;
all in accordance with the Drawings and Specification Section 503.0800
M

CT-01, 96.4 lps flow rate

nr

CT-02, 96.4 lps flow rate

nr

CT-03, 96.4 lps flow rate

nr

Supply and installation of Pressurization unit including all necessary


accessories, insulation, Pipe work, fittings, supports, fixings and
associated equipment; testing and commissioning, complete; all in
accordance with the Drawing and Specification 503.0700
Q

CHW- PR- 01, 6.70 lps flow rate at 350 kpa head

nr

CHW- PR- 02, 6.70 lps flow rate at 350 kpa head

nr

Items as Part of Value Engineering (**)


Carried to Collection
Supply and installation of air separator including all necessary
accessories, insulation, Pipe work, fittings, supports, fixings and
associated equipment; testing and commissioning, complete; all in
accordance with the Drawings and Specification
A

Air separator ref. AS - 01

nr

Air separator ref. AS - 02

nr

Supply and installation of centrifugal sand separator including all


necessary accessories, insulation, Pipe work, fittings, supports, fixings
and associated equipment; testing and commissioning, complete; all in
accordance with the Drawings and Specification
C

Sand separator ref.CSS-01

nr

Sand separator ref.CSS-02

nr

Sand separator ref.CSS-03

nr

Sand separator ref.CSS-04

nr

Supply and installation of primary chilled water pumps including all


controls, supports, gauges, flexible connections, accessories, mountings,
vibration isolator, wiring, labelling, supports bases and connection to
power supply for the proper operation of the system, testing and
commissioning, complete: accordance with the Drawings and
Specification Section 503.0900
G

CHWP-01, 50.24 lps flow rate at 150 ka head

nr

CHWP-02, 50.24 lps flow rate at 150 ka head

nr

CHWP-03, 50.24 lps flow rate at 150 ka head

nr

CHWP-04, 50.24 lps flow rate at 150 ka head

nr

Supply and installation of secondary chilled water pumps including all


controls, VFD, supports, gauges, flexible connections, accessories,
mountings, vibration isolator, wiring, labelling, supports bases and
connection to power supply for the proper operation of the system,
testing and commissioning, complete; all in accordance with the
Drawings and Specification Section 503.0900
L

CHWSP-01, 42.20 lps flow rate at 350 kpa head

nr

CHWSP-02, 42.20 lps flow rate at 350 kpa head

nr

CHWSP-03, 42.20 lps flow rate at 350 kpa head


Items as Part of Value Engineering (**)

nr

nr

Carried to Collection
A

CHWSP-04, 42.20 lps flow rate at 350 kpa head


Supply and installation of condenser water pumps including all controls,
supports, gauges, flexible connections, accessories, mountings, vibration
isolator, wiring, labelling, supports bases and connection to power supply
for the proper operation of the system, testing and commissioning,
complete; all in accordance with the Drawings and Specification Section
503.09

CWP-01, 76.4 lps flow rate at 200 kpa head

nr

CWP-02, 76.4 lps flow rate at 200 kpa head

nr

CWP-03, 76.4 lps flow rate at 200 kpa head

nr

CWP-04, 76.4 lps flow rate at 200 kpa head

nr

Supply and installation of air handling units, including all controls,


supports, accessories, fittings, flexible connections, gauges, mountings,
vibration isolator, wiring, labelling, final connections and associated
equipment, testing and commissioning, complete; all in accordance with
the Drawing and Specification Section 503.1100
F

AHU-01 , 2491 lps 38.3 kw sens. cooling capacity

nr

AHU-02, 2291 lps 35.0 kw sense. cooling capacity

nr

AHU-03, 3364 lps 56.5 kw sense. cooling capacity

nr

AHU-04, 1362 lps 30.7 kw sense. cooling capacity

nr

AHU-05, 4923 lps 67.1 kw sense, cooling capacity

nr

AHU-06, 2025 lps 24.5 kw sense. cooling capacity

nr

AHU-07, 1563 lps 27.2 kw sense. cooling capacity

nr

AHU- LG- 08,4700 lps 50.2 kw sense. cooling capacity

nr

AHU-09, 2957 lps 73.2 kw sense. cooling capacity

nr

AHU-10, 2758 lps 51.9 kw sense. cooling capacity

nr

Items as Part of Value Engineering (**)


Carried to Collection
Supply and installation of Energy Recovery Unit (ERU), including all
controls, filters, accessories, heat pipes, flexible connections, gauges,
mountings, vibration isolator, wiring, labelling, final connections and
associated equipment, testing and commissioning,complete; all in
accordance with the Drawing and Specification Section 503.1100
A

ERU -01, 2000 lps air vflow rate

nr

ERU -02, 2137 lps air flow rate

nr

ERU -03, 5092 lps air flow rate

nr

ERU -04, 3600 lps air flow rate

nr

ERU -05,4700 lps air flow rate

nr

Supply and installation of make-up air handling units, including all


controls, supports, accessories, fittings, flexible connections, gauges,
mountings, vibration isolator, wiring, labelling, final connections and
associated equipment, complete; testing and commissioning, all in
accordance with the Drawing and Specification Section 503.1100
F

MAHU-01, 6750 lps 185 kw sense. cooling capacity

nr

MAHU-02, 4325 lps 119 kw sense. cooling capacity

nr

MAHU-03, 1400 lps 38.2 kw sense. cooling capacity

nr

Supply and installation of Ecology unit (ECO), including all controls,

supports, accessories, fittings, flexible connections, gauges, mountings,


vibration isolator, wiring, labelling, final connections and associated
equipment, testing and commissioning,complete; all in accordance with
the Drawing and Specification Section 503.5100
J

ECO -01, 5500 lps

nr

ECO -02, 3850 lps

nr

Supply and installation fan coil units, including all controls, supports,
accessories, mountings, vibration isolator, wiring, labelling, final
connections and associated equipment,testing and commissioning,
complete; all in accordance with the Drawings and Specification Section
503.12
Lower Ground Floor
L

FCU -LG- 03

nr

FCU -LG- 04
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU -LG- 05

nr

FCU -LG- 06

nr

FCU -LG- 07A, 07B, & 07C

nr

FCU -LG- 10

nr

FCU -LG- 11

nr

FCU -LG- 13

nr

FCU -LG- 14

nr

FCU -LG- 15

nr

FCU -LG- 16

nr

FCU -LG- 17A, 17B & 17C

nr

FCU -LG- 19

nr

FCU -LG- 20

nr

FCU -LG- 22

nr

FCU -LG- 26

nr

FCU -LG- 32. 36 & 53

nr

FCU -LG- 38

nr

FCU -LG- 39

nr

FCU -LG- 40A, 40B & 40C

nr

FCU -LG- 44

nr

FCU -LG- 46A & 46B

nr

FCU -LG- 46

nr

FCU -LG- 48

nr

FCU -LG- 49

nr

FCU -LG- 52

nr

AA

FCU -LG- 59
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU -LG- 65

nr

FCU -LG- 69

nr

FCU -LG- 70

nr

FCU -LG- 71A & 71B

nr

FCU -LG- 72

nr

FCU -LG- 76A & 76B

nr

FCU -LG- 77

nr

FCU -LG- 81

nr

FCU -LG- 83A & 83B

nr

FCU -LG- 85

nr

FCU -LG- 87

nr

FCU -LG- 91

nr

FCU -LG- 93

nr

FCU -LG- 97

nr

FCU -LG- 98

nr

FCU -LG- 99

nr

FCU -LG- 100

nr

AA

FCU -LG- 101


Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU -LG- 103

nr

FCU -LG- 104

nr

FCU -LG- 105G & 105H

nr

FCU -LG- 105E & 105F

nr

FCU -LG- 105A, 105B, 105C & 105D

nr

FCU -LG- 107

nr

FCU -LG- 111

nr

FCU -LG- 112

nr

FCU -LG- 113A & 113B

nr

FCU -LG- 114

nr

FCU -LG- 119

nr

FCU -LG- 136

nr

FCU -LG- 140

nr

FCU -LG- 156

nr

FCU -LG- 162

nr

FCU -LG- 163

nr

FCU -LG- 169

nr

FCU -LG- 171

nr

FCU -LG- 174

nr

FCU -LG- 177

nr

FCU -LG- 180A & 180B

nr

FCU -LG- 183

nr

FCU -LG- 187

nr

FCU -LG- 191

nr

AA

FCU -LG- 193


Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU -LG- 194

nr

FCU -LG- 195

nr

FCU -LG- 196

nr

FCU -LG- 197

nr

FCU -LG- 199

nr

FCU -LG- 244

nr

FCU -LG- 301

nr

FCU -LG- 305

nr

FCU -LG- 306

nr

FCU -LG- 308

nr

FCU -LG- 309

nr

FCU -LG- 311

nr

FCU -LG- 312

nr

FCU -LG- 313

nr

FCU -LG- 324A, 324B & 324C

nr

FCU -LG- 325A & 325B

nr

FCU -LG- 336A

nr

FCU -LG- 336

nr

FCU -LG- 337

nr

FCU -LG- 347

nr

FCU -LG- 366A & 366B

nr

FCU -LG- 366

nr

Ground Floor
Y

FCU-00A1-1-A ( 1Bed ENE )

11

nr

FCU-00A1-1-B ( 1Bed ENE )


Items as Part of Value Engineering (**)

11

nr

Carried to Collection
A

FCU-00A1-1-A ( 1Bed ESE )

nr

FCU-00A1-1-B ( 1Bed ESE )

nr

FCU-00A1-1-A ( 1Bed NNE )

nr

FCU-00A1-1-B ( 1Bed NNE )

nr

FCU-00A1-1-A ( 1Bed SSW )

nr

FCU-00A1-1-B ( 1Bed SSW )

nr

FCU-00A1-1-A ( 1Bed WSW )

nr

FCU-00A1-1-B ( 1Bed WSW )

nr

FCU-00A1-1D-A ( 1Bed )

nr

FCU-00A1-1D-B ( 1Bed )

nr

FCU-00A1-2-A ( 1Bed ENE )

nr

FCU-00A1-2-B ( 1Bed ENE )

nr

FCU-00A1-2-A ( 1Bed WSW )

nr

FCU-00A1-2-B ( 1Bed WSW )

nr

FCU-00A1-C-A ( 1Bed ENE )

nr

FCU-00A1-C-B ( 1Bed ENE )

nr

FCU-00A1-C-A ( 1Bed NNW )

nr

FCU-00A1-C-B ( 1Bed NNW )

nr

FCU-00A1-C-A ( 1Bed WSW )

nr

FCU-00A1-C-B ( 1Bed WSW )

nr

FCU-00- 102A2-2-A ( 2Bed )

nr

FCU-00- 102A2-2-B ( 2Bed )

nr

FCU-00- 102A2-2-C ( 2Bed )

nr

FCU-00- 108A2-1.1-A ( 2Bed )

nr

AA

FCU-00- 108A2-1.1-B ( 2Bed )


Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-00- 108A2-1.1-C ( 2Bed )

nr

FCU-00- 37A1-4-A ( 1Bed )

nr

FCU-00- 37A1-4-A ( 1Bed )

nr

FCU-00- 40A1-3-A ( 1Bed )

nr

FCU-00- 40A1-3-B ( 1Bed )

nr

FCU-00- 49A1-9-A ( 1Bed )

nr

FCU-00- 49A1-9-A ( 1Bed )

nr

FCU-00- 55A2-3-A ( 2Bed )

nr

FCU-00- 55A2-3-B ( 2Bed )

nr

FCU-00- 55A2-3-C ( 2Bed )

nr

FCU-00- 56A3-1-A ( 3Bed )

nr

FCU-00- 56A3-1-B ( 3Bed )

nr

FCU-00- 56A3-1-C ( 3Bed )

nr

FCU-00- 56A3-1-D ( 3Bed )

nr

FCU-00- 57A3-2-A ( 3Bed )

nr

FCU-00- 57A3-2-B ( 3Bed )

nr

FCU-00- 57A3-2-C ( 3Bed )

nr

FCU-00- 57A3-2-D ( 3Bed )

nr

FCU-00-64A1-8-A ( 1Bed )

nr

FCU-00-64A1-8-A ( 1Bed )

nr

FCU-00-67A3-3-A ( 3Bed )

nr

FCU-00-67A3-3-B ( 3Bed )

nr

FCU-00-67A3-3-C ( 3Bed )

nr

FCU-00-67A3-3-D ( 3Bed )

nr

AA

FCU-00-75A1-5.1-A ( 1Bed )
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-00-75A1-5.1-A ( 1Bed )

nr

FCU-00-82A2-10-A ( 2Bed )

nr

FCU-00-82A2-10-B ( 2Bed )

nr

FCU-00-82A2-10-C ( 2Bed )

nr

FCU-00-84A2-6.1-A ( 2Bed )

nr

FCU-00-84A2-6.1-B ( 2Bed )

nr

FCU-00-84A2-6.1-C ( 2Bed )

nr

FCU-00-89A2-5.1-A ( 2Bed )

nr

FCU-00-89A2-5.1-B ( 2Bed )

nr

FCU-00-89A2-5.1-C ( 2Bed )

nr

FCU-00-99A2-4-A ( 2Bed )

nr

FCU-00-99A2-4-B ( 2Bed )

nr

FCU-00-99A2-4-C ( 2Bed )

nr

FCU-00- 01

nr

FCU-00- 06

nr

FCU-00- 11

nr

FCU-00- 17

nr

FCU-00- 19

nr

FCU-00- 22

nr

FCU-00- 23

nr

FCU-00- 27

nr

FCU-00- 31

nr

FCU-00- 32

nr

FCU-00- 33

nr

AA

FCU-00- 34
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-00- 70

nr

FCU-00- 72

nr

FCU-00- 78

nr

FCU-00- 81

nr

FCU-00- 90

nr

FCU-00- 92

nr

FCU-00- 97

nr

FCU-00- 103

nr

FCU-00- 105 -01

nr

FCU-00- 105 -02

nr

FCU-00- 109

nr

FCU-00- 111

nr

Level 1
N

FCU-01A1-1-A ( 1Bed ENE )

14

nr

FCU-01A1-1-B ( 1Bed ENE )

14

nr

FCU-01A1-1-A ( 1Bed ESE )

nr

FCU-01A1-1-B ( 1Bed ESE )

nr

FCU-01A1-1-A ( 1Bed NNE )

nr

FCU-01A1-1-B ( 1Bed NNE )

nr

FCU-01A1-1-A ( 1Bed SSW )

nr

FCU-01A1-1-B ( 1Bed SSW )

nr

FCU-01A1-1-A ( 1Bed WSW )

nr

FCU-01A1-1-B ( 1Bed WSW )

nr

FCU-01 D- 1 ( Double E )

nr

FCU-01 D- 1 ( Double ENE )


Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-01 D- 1 ( Double NNW )

nr

FCU-01 D- 1 ( Double SSE )

nr

FCU-01 D- 1 ( Double WSW )

nr

FCU-01 K- 1 ( King E )

nr

FCU-01 K- 1 ( King ENE )

nr

FCU-01 K- 1 ( King NNW )

nr

FCU-01 K- 1 ( King NNW )

nr

FCU-01 K- 1 ( King SSE )

nr

FCU-01 K- 1 ( King WSW )

nr

FCU-01- 02 ( D-2 Double )

nr

FCU-01- 03- A ( VIP )

nr

FCU-01- 03- B ( VIP )

nr

FCU-01- 041- A ( S-1 Suite )

nr

FCU-01- 04- B ( S-1 Suite )

nr

FCU-01- 06 ( K 3 King )

nr

FCU-01- 100 ( K-7 King )

nr

FCU-01- 108 ( K-4 King )

nr

FCU-01- 110

nr

FCU-01- 192

nr

FCU-01- 21- A

nr

FCU-01- 21- B

nr

FCU-01- 26

nr

FCU-01- 27

nr

FCU-01- 31

nr

AA

FCU-01- 46
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-01- 47- A

nr

FCU-01- 47- B

nr

FCU-01- 47- C

nr

FCU-01- 47- D

nr

FCU-01- 48- A

nr

FCU-01- 48- B

nr

FCU-01- 48- C

nr

FCU-01- 48- D

nr

FCU-01- 58- A

nr

FCU-01- 58- B

nr

FCU-01- 58- C

nr

FCU-01- 58- D

nr

FCU-01- 59- A

nr

FCU-01- 59- B

nr

FCU-01- 59- C

nr

FCU-01- 59- D

nr

FCU-01- 60- A

nr

FCU-01- 60- B

nr

FCU-01- 62- A

nr

FCU-01- 62- B

nr

FCU-01- 65

nr

FCU-01- 68

nr

FCU-01- 69- A

nr

FCU-01- 69- B

nr

AA

FCU-01- 69- C
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-01- 71- A

nr

FCU-01- 71- B

nr

FCU-01- 71- C

nr

FCU-01- 75- A

nr

FCU-01- 75- B

nr

FCU-01- 75- C

nr

FCU-01- 76

nr

FCU-01- 80

nr

FCU-01- 83

nr

FCU-01- 64- A

nr

FCU-01- 84- B

nr

FCU-01- 84- C

nr

FCU-01- 87- A

nr

FCU-01- 87- B

nr

FCU-01- 87- C

nr

FCU-01- 88

nr

FCU-01- 93- A

nr

FCU-01- 93- B

nr

FCU-01- 93- C

nr

FCU-01- 94

nr

FCU-01- 96

nr

FCU-01- 99- A

nr

FCU-01- 99- B

nr

14

nr

Level 2
Z

FCU-02A1-1-A ( 1Bed ENE )


Items as Part of Value Engineering (**)
Carried to Collection

FCU-02A1-1-B ( 1Bed ENE )

14

nr

FCU-02A1-1-A ( 1Bed ESE )

nr

FCU-02A1-1-B ( 1Bed ESE )

nr

FCU-02A1-1-A ( 1Bed NNE )

nr

FCU-02A1-1-B ( 1Bed NNE )

nr

FCU-02A1-1-A ( 1Bed SSW )

nr

FCU-02A1-1-B ( 1Bed SSW )

nr

FCU-02A1-1-A ( 1Bed WSW )

nr

FCU-02A1-1-B ( 1Bed WSW )

nr

FCU-02A1-1-C ( 1Bed WSW )

nr

FCU-02A1-1-D ( 1Bed WSW )

nr

FCU-02 D- 1 ( Double E )

nr

FCU-02 D- 1 ( Double ENE )

nr

FCU-02 D- 1 ( Double NNW )

nr

FCU-02 D- 1 ( Double SSE )

nr

FCU-02 D- 1 ( Double SSE )

nr

FCU-02 D- 1 ( Double WSW )

nr

FCU-02 K- 1 ( King E )

nr

FCU-02 K- 1 ( King E )

nr

FCU-02 K- 1 ( King ENE )

nr

FCU-02 K- 1 ( King NNW )

nr

FCU-02 K- 1 ( King SSE )

nr

FCU-02 K- 1 ( King WSW )

nr

FCU-02 K- 1 ( King WSW )

nr

AA

FCU-02- 01- A
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-02- 01- B

nr

FCU-02- 01- C

nr

FCU-02- 10- A

nr

FCU-02- 10- B

nr

FCU-02- 101- A

nr

FCU-02- 101- B

nr

FCU-02- 101- C

nr

FCU-02- 102

nr

FCU-02- 104

nr

FCU-02- 106- A

nr

FCU-02- 106- B

nr

FCU-02- 106- C

nr

FCU-02- 114

nr

FCU-02- 116

nr

FCU-02- 20

nr

FCU-02- 27- A

nr

FCU-02- 27- B

nr

FCU-02- 32

nr

FCU-02- 33

nr

FCU-02- 36

nr

FCU-02- 53- A

nr

FCU-02- 53- B

nr

FCU-02- 53- C

nr

FCU-02- 54- A

nr

AA

FCU-02- 54- B
Items as Part of Value Engineering (**)

nr

nr

Carried to Collection
A

FCU-02- 54- C

FCU-02- 55- A

nr

FCU-02- 55- B

nr

FCU-02- 55- C

nr

FCU-02- 65- A

nr

FCU-02- 65- B

nr

FCU-02- 65- C

nr

FCU-02- 65- D

nr

FCU-02- 68- A

nr

FCU-02- 68- B

nr

FCU-02- 69- A

nr

FCU-02- 69- B

nr

FCU-02- 71- A

nr

FCU-02- 71- B

nr

FCU-02- 74

nr

FCU-02- 77- A

nr

FCU-02- 77- B

nr

FCU-02- 77- C

nr

FCU-02- 79- A

nr

FCU-02- 79- B

nr

FCU-02- 79- C

nr

FCU-02- 83- A

nr

FCU-02- 83- B

nr

FCU-02- 83- C

nr

AA

FCU-02- 84
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

FCU-02- 88

nr

FCU-02- 91

nr

FCU-02- 92- A

nr

FCU-02- 92- B

nr

FCU-02- 92- C

nr

FCU-02- 95- A

nr

FCU-02- 95- B

nr

FCU-02- 95- C

nr

FCU-02- 96

nr

Level 3
K

FCU -03- 02

nr

FCU -03- 03

nr

FCU -03- 06

nr

FCU -03- 07

nr

FCU -03- 08

nr

FCU -03- 10

nr

FCU -03- 11

nr

FCU -03- 12

nr

FCU -03- 13

nr

FCU -03- 14

nr

nr

Supply and installation refrigerant condensing unit, including all controls,


supports, pipe works,valves, gauges, mountings, vibration isolator,
wiring, labelling, final connections, testing and commissioning, complete;
all in accordance with the Drawings and Specification Section 503.1300
V

FCU -LG- 204A & 204B

FCU- LG- 204C

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

FCU -LG- 10S

nr

FCU -00 -111

nr

Allow for the refrigerant Pipe work with all necessary insulation, fittings,
valves, accessories, and electrical final connection, complete; all in
accordance with the Drawings ans Specification

item

nr

611

nr

Supply and installation of water conditioning equipment including all


necessary pumps, vessels, valves, controls, accessories, base frames,
vibration isolator, control panel, wiring, labelling and other required
materials, complete; all in accordance with the Drawings and
Specification
D

Automatic & manual chemical dosing system


Supply and installation of thermostats including all electrical connections,
complete; all in accordance with the Drawings and Specification

Room thermostat; allowance


Carbon monoxide detection system
Supply and installation of carbon monoxide detection system including
cables, conduits, necessary accessories and interfacing with the BMCS
system, complete; all in accordance with the Drawings and Specification

Carbon monoxide control panels

item

CO sensor

16

nr

Grilles, diffusers, dampers and accessories


Supply and installation of extract air louvers, complete; all as per the
Drawings and Specification Section 503.1900
H

Extract air louver - 7700 x 700mm H

nr

Carpark extract air louver, face area 25m2

nr

Carpark extract air louver - 10000 x 1700mm H

nr

Carpark extract air louver - 8800 x 2100mm H

nr

Extract air louver with insect wire mesh screen, 1600 x 1000mm

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

Extract air louver with insect wire mesh screen, 2000 x 1500mm

nr

Extract air louver with insect wire mesh screen, 2000 x 1700mm

nr

Extract air louver with insect wire mesh screen, 2500 x 2000mm

nr

Extract air louver with insect wire mesh screen, 3000 x 2500mm

nr

Garbage discharge air louver c/ w wire mesh - 700 x 300mm H

nr

Extract air louver with bird & insect wire mesh screen to ERU- 01 to ERU5

nr

Extract air louver with bird & insect wire mesh screen to AHU- 03 to AHU7

nr

Extract air louver with bird & insect wire mesh screen to AHU- 09 &
AHU- 10

nr

Supply and installation of intake air louvers, complete; all as per the
Drawings and Specification Section 503.1900
J

Fresh air intake louver - 7700 x 700mm H

nr

Operable make up air intake louver - 1500 x 1200mm

nr

Carpark fresh air treated air louver, face area 25.1 m2

nr

Fresh air sand trap louver to ERU -01 to ERU- 05

nr

Fresh air sand trap louver to LPF- 01 to LPF- 06

nr

Fresh air sand trap louver to AHU- 03 to HU- 07

nr

Fresh air sand trap louver to AHU- 09 & AHU- 10

nr

293

nr

Supply and installation of supply diffusers (SD), complete; all in


accordance with the Drawings and Specification Section 503.3200
R

SD - 150 x 150mm

SD - 225 x 225mm

159

nr

SD - 300 x 300mm

43

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

SD - 375 x 375mm

nr

SD - 600 x 600mm

44

nr

SD - 200mm diameter

104

nr

SD - 250mm diameter

34

nr

Supply and installation of supply air grille (SAG), complete; all in


accordance with the Drawings and Specification Section 503.1700
E

SG - 200 x 150mm

nr

SG - 200 x 200mm

nr

SG - 250 x 200mm

nr

SG - 300 x 200mm

nr

SG - 300 x 250mm

nr

SG - 400 x 200mm

nr

SG - 400 x 250mm

nr

SG - 450 x 250mm

nr

SG - 500 x 200mm

11

nr

SG - 500 x 250mm

nr

SG - 600 x 200mm

115

nr

SG - 600 x 250mm

277

nr

SG - 600 x 300mm

nr

SG - 600 x 400mm

nr

SG - 700 x 250mm

17

nr

SG - 700 x 300mm

nr

SG - 800 x 250mm

10

nr

SG - 850 x 250mm

nr

SG - 900 x 250mm

38

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

SG - 900 x 300mm

nr

SG - 900 x 400mm

nr

SG - 1000 x 250mm

nr

SG - 1000 x 300mm

nr

SG - 1000 x 400mm

nr

Supply and installation of supply linear slot diffuser (SLSD), complete; all
in accordance with the Drawings and Specification Section 503.1700
F

SLSD - 1000mm length x 2 slot, 20mm slot width

138

nr

SLSD - 1000mm length x 3 slot, 20mm slot width

38

nr

SLSD - 1000mm length x 4 slot, 20mm slot width

59

nr

nr

32

nr

192

nr

Supply and installation of egg crate grille (ECG), complete; all in


accordance with the Drawings and Specification Section 503.1700
J

ECG - 600 x 600mm


Supply and installation of supply air diffuser , complete; all in accordance
with the Drawings and Specification

SD - 600 x 600mm, 4- way


Supply and installation of fresh air diffuser (FAD), complete; all in
accordance with the Drawings and Specification

FAD - 300 x 300mm


Supply and installation of ceiling diffuser to Hotel Corridor, complete; all

in accordance with the Drawings and Specification


M

Ceiling round diffuser to Hotel Corridor

154

nr

42

nr

20

nr

176

nr

Supply and installation of supply linear bar grille (SLBG), complete; all in
accordance with the Drawings and Specification
N

SLBG - 1000mm length x 200mm H, 1- way


Supply and installation of stair pressurization air grille (SPG), complete;
all in accordance with the Drawings and Specification

pressurization grille with balancing damper to SPF


Items as Part of Value Engineering (**)
Carried to Collection
Supply and installation of extract air diffusers (EAD), complete; all in
accordance with the Drawings and Specification

EAD - 300 x 300mm


Supply and installation of return diffusers (RD), complete; all in
accordance with the Drawings and Specification
Supply and installation of stair pressurization air grille (SPG), complete;
all in accordance with the Drawings and Specification Section 503.1700

RD - 150 x 150mm

39

nr

RD - 225 x 225mm

124

nr

RD - 300 x 300mm

43

nr

RD - 375 x 375mm

nr

RD - 600 x 600mm

38

nr

RD - 200mm diameter

94

nr

RD - 250mm diameter

34

nr

Supply and installation of return grills (RG), complete; all in accordance


with the Drawings and Specification
J

RG - 200 x 150mm

nr

RG - 200 x 200mm

nr

RG - 250 x 200mm

nr

RG - 300 x 200mm

nr

RG - 300 x 250mm

nr

RG - 400 x 200mm

nr

RG - 400 x 250mm

nr

RG - 500 x 200mm

nr

RG - 500 x 250mm

nr

RG - 600 x 200mm

108

nr

RG - 600 x 250mm
Items as Part of Value Engineering (**)

292

nr

Carried to Collection
A

RG - 600 x 300mm

nr

RG - 600 x 400mm

nr

RG - 700 x 250mm

16

nr

RG - 700 x 300mm

nr

RG - 800 x 250mm

10

nr

RG - 850 x 250mm

nr

RG - 900 x 250mm

38

nr

RG - 900 x 400mm

nr

RG - 1000 x 250mm

nr

RG - 1000 x 300mm

nr

RG - 1000 x 400mm

nr

RG - 2000 x 1000mm

nr

138

nr

Supply and installation of return linear slot diffuser (RLSD), complete; all
in accordance with the Drawings and Specification
N

RLSD - 1000mm length x 2 slot, 20mm slot width

RLSD - 1000mm length x 3 slot, 20mm slot width

38

nr

RLSD - 1000mm length x 4 slot, 20mm slot width

59

nr

nr

Supply and installation of core grille, complete; all in accordance with the
Drawings and Specification
R

Cube core grille - 18000 x 400mm H


Supply and installation of return linear diffuser (RLD), complete; all in
accordance with the Drawings and Specification

Return linear slot diffuser along ceiling surface

65

Return linear bar grille along ceiling cove

12

nr

Supply and installation of the sound attenuators (SA), complete; all in


accordance with the Drawings and Specification
U

SA - 200 x 200mm
Items as Part of Value Engineering (**)
Carried to Collection

SA - 250 x 200mm

nr

SA - 400 x 400mm

nr

SA - 500 x 450mm

nr

SA - 500 x 500mm

nr

SA - 600 x 300mm

nr

SA - 600 x 450mm

nr

SA - 600 x 500mm

nr

SA - 700 x 350mm

nr

SA - 900 x 400mm

nr

SA - 900 x 450mm

nr

SA - 900 x 500mm

nr

SA - 900 x 600mm

nr

SA - 950 x 600mm

nr

SA - 1000 x 600mm

nr

SA - 1000 x 500mm

nr

SA - 1000 x 700mm

nr

SA - 1150 x 600mm

nr

SA - 1100 X 550mm

nr

SA - 1100 x 600mm

nr

SA - 1200 x 600mm

12

nr

SA - 1300 x 600mm

nr

SA - 1300 x 700mm

nr

SA - 1400 x 700mm

nr

SA - 1500 x 700mm

nr

AA

SA -1600 x 950mm
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

SA - 2000 x 850mm

nr

SA to AHU- 06

nr

Supply and installation of motorized dampers (MD), complete; all in


accordance with the Drawings and Specification
C

MD - 200 x 150mm

nr

MD - 200 x 200mm

11

nr

MD - 250 x 200mm

nr

MD - 300 x 200mm

nr

MD - 300 x 250mm

nr

MD - 350 x 200mm

nr

MD - 300 x 300mm

nr

MD - 350 x 300mm

nr

MD - 400 x 250mm

nr

MD - 400 x 300mm

nr

MD - 550 x 300mm

nr

MD - 600 x 300mm

nr

MD - 600 x 450mm

nr

MD - 700 x 400mm

nr

MD - 900 x 450mm

nr

MD - 900 x 500mm

nr

MD - 900 x 600mm

nr

MD - 950 x 600mm

nr

MD - 1000 x 600mm

nr

MD - 1000 x 700mm

nr

MD - 1100 x 500mm

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

MD - 1100 x 600mm

nr

MD - 1150 x 600mm

nr

MD - 1200 x 600mm

10

nr

MD - 1300 x 600mm

nr

MD - 1350 x 700mm

nr

MD - 1400 x 700mm

nr

MD - 1500 x 700mm

nr

MD - 1600 x 950mm

nr

MD - 1200 x 750mm

nr

MD - 2000 x 1000mm

nr

MD - 2500 x 650mm

nr

MD - to AHU- 03 to AHU- 07, AHU- 09 & AHU- 10

14

nr

Supply and installation of volume control dampers (VCD), complete; all in


accordance with the Drawings and Specification
N

VCD -100 x 100mm

241

nr

VCD -150 x 100mm

700

nr

VCD -150 x 150mm

269

nr

VCD - 200 x 100mm

59

nr

VCD -200 x 150mm

303

nr

VCD -200 x 200mm

187

nr

VCD - 225 x 225mm

50

nr

VCD -250 x 150mm

nr

VCD -250 x 200mm

193

nr

VCD - 250 x 250mm

nr

VCD -300 x 200mm

18

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

VCD -300 x 250mm

nr

VCD - 300 x 300mm

22

nr

VCD -350 x 200mm

28

nr

VCD -350 x 250mm

nr

VCD - 350 x 300mm

nr

VCD -400 x 200mm

62

nr

VCD - 400 x 250mm

nr

VCD - 400 x 300mm

15

nr

VCD - 400 x 350mm

nr

VCD - 400 x 400mm

nr

VCD -450 x 150mm

nr

VCD - 450 x 300mm

nr

VCD -500 x 200mm

nr

VCD - 500 x 300mm

nr

VCD -500 x 350mm

nr

VCD - 600 x 500mm

nr

VCD - 650 x 300mm

nr

VCD - 700 x 300mm

nr

VCD - 700 x 350mm

nr

VCD - 800 x 500mm

nr

VCD - 800 x 400mm

nr

VCD - 900 x 400mm

nr

VCD - 950 x 400mm

nr

VCD - 200mm diameter

168

nr

AA

VCD - 250mm diameter


Items as Part of Value Engineering (**)

72

nr

14

nr

Carried to Collection
A

VCD - 300mm diameter


Supply and installation of fire dampers (FD), complete; all in accordance
with the Drawings and Specification

FD - 100 x 100mm

26

nr

FD - 150 x 100mm

65

nr

FD - 150 x 150mm

54

nr

FD - 200 x 100mm

55

nr

FD - 200 x 150mm

228

nr

FD - 200 x 200mm

145

nr

FD - 250 x 200mm

41

nr

FD - 300 x 200mm

10

nr

FD - 300 x 250mm

nr

FD - 350 x 200mm

nr

FD - 350 x 300mm

nr

FD - 400 x 250mm

nr

FD - 400 x 300mm

nr

FD - 500 x 350mm

nr

FD - 550 x 300mm

nr

FD - 700 x 300mm

nr

FD - 700 x 350mm

nr

FD - 700 x 400mm

nr

FD - 800 x 400mm

nr

FD - 800 x 500mm

nr

FD - 900 x 400mm

nr

FD - 900 x 450mm

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

FD - 900 x 500mm

nr

FD - 1100 x 600mm

nr

FD - 2000 x 1000mm

nr

FD - to AHU- 06

nr

Supply and installation of non return dampers (NRD), complete; all in


accordance with the Drawings and Specification

NRD - 1100 x 500mm

nr

NRD - 1200 x 750mm

nr

NRD - 1600 x 950mm

nr

NRD - 2500 x 650mm

nr

Supply and installation of VAV, complete; all in accordance with the


Drawings and Specification
J

VAV - 00- 01S

nr

VAV - 00- 02R

nr

nr

Supply and installation of dehumidifier, complete; all in accordance with


the Drawings and Specification
L

Dehumidifier

Items as Part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.5
5F: SPACE HEATING AND AIR TREATMENT

COLLECTION
Page No
-227-

Total Brought Forward from Page No.

-228-229-230-231-232-233-234-235-236-237-238-239-240-241-242-243-244-245Items as Part of Value Engineering (**)


Carried Forward
Section No.6
SERVICES
Bill No.5

5F: SPACE HEATING AND AIR TREATMENT


COLLECTION
Page No

-246-

Total Brought Forward from Page No.

-247-248-249-250-251-252-253-254-255-256-257-258-259-260-261-262-263Items as Part of Value Engineering (**)


Carried Forward
Section No.6

SERVICES
Bill No.5
5F: SPACE HEATING AND AIR TREATMENT
COLLECTION
Page No

Total Brought Forward from Page No.

-264-265-

Items as Part of Value Engineering (**)

Carried Forward to Summary of Section No. 6

5H: ELECTRICAL INSTALLATIONS


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.
Generator
Supply and installation of generator including fixing, fittings, earth & main
connections, complete; all in accordance with the Drawings and
Specification Section 615:0100
A

2000kVA 400V, 60Hz prime rated diesel generator including AMF board

nr

Transformer
Supply and installation of transformers, meter and cables including fixing,
fittings, busbar, electrical interlocks, inter trips, check synchronizing
circuits, earth & main connections, complete; all in accordance with the
Drawings and Specification Section 611:0100
B

Transformer-1, 2000kVA 13.8kV/400V Cast Resin

nr

Transformer-2, 2000kVA 13.8kV/400V Cast Resin

nr

Transformer-3, 2000kVA 13.8kV/400V Cast Resin

nr

Transformer-4, 2000kVA 13.8kV/400V Cast Resin

nr

Transformer-5, 2000kVA 13.8kV/400V Cast Resin

nr

Transformer-6, 2000kVA 13.8kV/400V Cast Resin

nr

Capacitor bank
Supply and installation of multi step capacitor bank with automatic
recitative power regulator including MCCB, fixing, fittings, electrical
interlocks, inter trips, check synchronizing circuits, earth & main
connections, complete; all in accordance with the Drawings and
Specification Section 617:0100-0300
H

350kVAR 8 Step auto PFC Cap. Panel-1

nr

350kVAR 8 Step auto PFC Cap. Panel-2

nr

350kVAR 8 Step auto PFC Cap. Panel-3

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

350kVAR 8 Step auto PFC Cap. Panel-4

nr

350kVAR 8 Step auto PFC Cap. Panel-5

nr

350kVAR 8 Step auto PFC Cap. Panel-6

nr

Automatic transfer switch


Supply and installation of automatic transfer switch including fittings and
supports, complete; all in accordance with the Drawings and
Specification
D

1800A 4P Automatic transfer switch-1

nr

1800A 4P Automatic transfer switch-2

nr

125A 4P Automatic transfer switch-3

nr

nr

Note: For each type of panels main and branches ampere rating, number
of branches and rating refer to schematic diagram & load schedule and
for brand name/manufacturer refer to electrical specification.
MV PANEL
Supply and installation of MV panel including circuit breakers,
electromechanical interlock, meters, cable trays/trunking for final
connections and steel mounting structure, complete; all in accordance
with the Drawings and Specification Section 613:0100-0300
G

MV Panel -1 & 2
Main distribution board
Supply and installation of main distribution boards including circuit
breakers, electromechanical interlock, meters, cable trays/trunking for
final connections and steel mounting structure, complete; all in
accordance with the Drawings and Specification Section 618:0800

MDB-01

nr

MDB-02

nr

MDB-03

nr

MDB-04

nr

MDB-05

nr

MDB-06
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

EMDB

nr

EMDB-CBS

nr

MDB-UPS-1

nr

Sub main distribution board


Supply and installation of sub main distribution boards including circuit
breakers, electromechanical interlock, meters, cable trays/trunking for
final connections and steel mounting structure, complete; all in
accordance with the Drawings and Specification Section 618:0900
D

SMDB-LG-H2

nr

SMDB-LAUNDRY

nr

SMDB-S/S

nr

SMDB-FOH-H

nr

SMDB-GF-H2

nr

SMDB-GF-KIT

nr

SMDB-GF-H1-A

nr

SMDB-GF-H1-B

nr

SMDB-FF-H1-A

nr

SMDB-FF-H1-B

nr

SMDB-SF-H1-A

nr

SMDB-SF-H1-B

nr

SMDB-R1

nr

SMDB-R2

nr

SMDB-SF-H2

nr

SMDB-GH

nr

SMDB-FF-H2

nr

SMDB-GF-H2

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

SMDB-KIT-1

nr

SMDB-KIT-2

nr

SMDB-LG-A2

nr

SMDB-LG-A1

nr

SMDB-LG-H1

nr

SMDB-GF-A2-A

nr

SMDB-GF-A2-B

nr

SMDB-FF-A2-A

nr

SMDB-FF-A2-B

nr

SMDB-SF-A2-A

nr

SMDB-SF-A2-B

nr

SMDB-GF-A1-A

nr

SMDB-GF-A1-B

nr

SMDB-FF-A1-A

nr

SMDB-FF-A1-B

nr

SMDB-SF-A1-A

nr

SMDB-SF-A1-B

nr

SMDB-LIFT-A1

nr

SMDB-LG-PL1

nr

SMDB-LG-PL2

nr

SMDB-HC (HEALTH CLUB)

nr

ESMDB-FP-2

nr

ESMDB-A

nr

ESMDB-H

nr

AA

ES-SMDB-LG-H2
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

ES-SMDB-LG-H1

nr

ES-SMDB-GF-H2

nr

ES-SMDB-LIFTS-H1

nr

ELSMDB-LG-H2

nr

ELSMDB-LG-H1

nr

ELSMDB-LG-A1

nr

ELSMDB-LG-A2

nr

ES-SMDB-LG-A1

nr

ES-SMDB-LG-A2

nr

ES-SMDB-LG-PL1

nr

ES-SMDB-LIFT-A1

nr

ES-SMDB-FOH-H

nr

ES-SMDB-KIT

nr

nr

Distribution board

Supply and installation of distribution boards including circuit breakers,


electromechanical interlock, meters, cable trays/trunking for final
connections and steel mounting structure, complete; all in accordance
with the Drawings and Specification Section 618:1000
guest room & apartment panel can be reduced 12 way & 18 way (**)
DB-SF-CH2

DB-SF-H2-1

nr

DB-SF-H2-2

nr

DB-SF-H2-3

nr

DB-SF-H2-4

nr

DB-SF-H2-5

nr

DB-SF-H2-6

nr

DB-SF-H2-7

nr

Items as part of Value Engineering (**)


Carried to Collection
A

DB-SF-H2-8

nr

DB-SF-H2-9

nr

DB-SF-H2-10

nr

DB-SF-H2-11

nr

DB-SF-H2-12

nr

DB-SF-H2-13

nr

DB-SF-H2-14

nr

DB-SF-H2-15

nr

DB-SF-H2-16

nr

DB-SF-H2-17

nr

DB-SF-H2-18

nr

DB-SF-H2-19

nr

DB-SF-H2-20

nr

DB-SF-H2-21

nr

DB-SF-H2-22

nr

DB-SF-H2-23

nr

DB-SF-H2-24

nr

DB-SF-H2-25

nr

DB-SF-H2-26

nr

DB-SF-H2-27

nr

DB-SF-H2-28

nr

DB-SF-H2-29

nr

DB-GH

nr

DB-HVR

nr

AA

DB-FF-CH2
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-FF-H2-1

nr

DB-FF-H2-2

nr

DB-FF-H2-3

nr

DB-FF-H2-4

nr

DB-FF-H2-5

nr

DB-FF-H2-6

nr

DB-FF-H2-7

nr

DB-FF-H2-8

nr

DB-FF-H2-9

nr

DB-FF-H2-10

nr

DB-FF-H2-11

nr

DB-FF-H2-12

nr

DB-FF-H2-13

nr

DB-FF-H2-14

nr

DB-FF-H2-15

nr

DB-FF-H2-16

nr

DB-FF-H2-17

nr

DB-FF-H2-18

nr

DB-FF-H2-19

nr

DB-FF-H2-20

nr

DB-FF-H2-21

nr

DB-FF-H2-22

nr

DB-CP-H2

nr

DB-SEC

nr

AA

DB-BR1
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-BR2

nr

DB-BR3

nr

DB-LV

nr

DB-HV

nr

DB-TR

nr

DB-EXT.LTG

nr

DB-KIT-1

nr

DB-KIT-2

nr

DB-KIT-3

nr

DB-KIT-4

nr

DB-KIT-5

nr

DB-GF-KIT-1

nr

DB-GF-KIT-2

nr

DB-GF-EX-KIT

nr

DB-RH1

nr

DB-RH2

nr

DB-SF-CH1

nr

DB-SF-H1-1

nr

DB-SF-H1-2

nr

DB-SF-H1-3

nr

DB-SF-H1-4

nr

DB-SF-H1-5

nr

DB-SF-H1-6

nr

DB-SF-H1-7

nr

AA

DB-SF-H1-8
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-SF-H1-9

nr

DB-SF-H1-10

nr

DB-SF-H1-11

nr

DB-SF-H1-12

nr

DB-SF-H1-13

nr

DB-SF-A3-1

nr

DB-SF-A3-2

nr

DB-SF-A3-3

nr

DB-SF-A3-4

nr

DB-SF-A3-5

nr

DB-SF-A3-6

nr

DB-SF-A3-7

nr

DB-SF-A3-8

nr

DB-SF-A3-9

nr

DB-SF-A3-10

nr

DB-SF-A3-11

nr

DB-SF-A3-12

nr

DB-FF-CH1

nr

DB-FF-H1-1

nr

DB-FF-H1-2

nr

DB-FF-H1-3

nr

DB-FF-H1-4

nr

DB-FF-H1-5

nr

DB-FF-H1-6

nr

AA

DB-FF-H1-7
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-FF-H1-8

nr

DB-FF-H1-9

nr

DB-FF-H1-10

nr

DB-FF-H1-11

nr

DB-FF-H1-12

nr

DB-FF-H1-13

nr

DB-FF-H1-14

nr

DB-FF-H1-15

nr

DB-FF-H1-16

nr

DB-FF-A3-1

nr

DB-FF-A3-2

nr

DB-FF-A3-3

nr

DB-FF-A3-4

nr

DB-FF-A3-5

nr

DB-FF-A3-6

nr

DB-FF-A3-7

nr

DB-FF-A3-8

nr

DB-FF-A3-9

nr

DB-FF-A3-10

nr

DB-FF-A3-11

nr

DB-GF-CH1

nr

DB-GF-A3-1

nr

DB-GF-A3-2

nr

DB-GF-A3-3

nr

AA

DB-GF-A3-4
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-GF-A3-5

nr

DB-GF-A3-6

nr

DB-GF-A3-7

nr

DB-GF-A3-8

nr

DB-GF-A3-9

nr

DB-GF-A3-10

nr

DB-GF-A3-11

nr

DB-GF-A3-12

nr

DB-GF-A3-13

nr

DB-GF-A3-14

nr

DB-GF-A3-15

nr

DB-GF-A3-16

nr

DB-GF-A3-17

nr

DB-GF-A3-18

nr

DB-FOH-H1

nr

DB-FOH-H2

nr

DB-FOH-H3

nr

DB-FOH-H4

nr

DB-CP-H1

nr

DB-FF-CA2

nr

DB-FF-A2-1

nr

DB-FF-A2-2

nr

DB-FF-A2-3

nr

DB-FF-A2-4

nr

AA

DB-FF-A2-5
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-FF-A2-6

nr

DB-FF-A2-7

nr

DB-FF-A2-8

nr

DB-FF-A2-9

nr

DB-FF-A2-10

nr

DB-FF-A2-11

nr

DB-FF-A2-12

nr

DB-FF-A2-13

nr

DB-FF-A2-14

nr

DB-FF-A2-15

nr

DB-FF-A2-16

nr

DB-LG-PL2

nr

DB-GF-CA2

nr

DB-GF-A2-1

nr

DB-GF-A2-2

nr

DB-GF-A2-3

nr

DB-GF-A2-4

nr

DB-GF-A2-5

nr

DB-GF-A2-6

nr

DB-GF-A2-7

nr

DB-GF-A2-8

nr

DB-GF-A2-9

nr

DB-GF-A2-10

nr

DB-GF-A2-11

nr

AA

DB-GF-A2-12
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-GF-A2-13

nr

DB-GF-A2-14

nr

DB-GF-A2-15

nr

DB-GF-A2-16

nr

DB-CP-A2

nr

DB-FOH-A2

nr

DB-SF-CA2

nr

DB-SF-A2-1

nr

DB-SF-A2-2

nr

DB-SF-A2-3

nr

DB-SF-A2-4

nr

DB-SF-A2-5

nr

DB-SF-A2-6

nr

DB-SF-A2-7

nr

DB-SF-A2-8

nr

DB-SF-A2-9

nr

DB-SF-A2-10

nr

DB-SF-A2-11

nr

DB-SF-A2-12

nr

DB-SF-A2-13

nr

DB-SF-A2-14

nr

DB-SF-A2-15

nr

DB-SF-A2-16

nr

DB-SF-A2-17

nr

AA

DB-SF-A2-18
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-SF-CA1

nr

DB-SF-A1-1

nr

DB-SF-A1-2

nr

DB-SF-A1-3

nr

DB-SF-A1-4

nr

DB-SF-A1-5

nr

DB-SF-A1-6

nr

DB-SF-A1-7

nr

DB-SF-A1-8

nr

DB-SF-A1-9

nr

DB-SF-A1-10

nr

DB-SF-A1-11

nr

DB-SF-A1-12

nr

DB-SF-A1-13

nr

DB-SF-A1-14

nr

DB-SF-A1-15

nr

DB-SF-A1-16

nr

DB-SF-A1-17

nr

DB-RA2

nr

DB-RA1

nr

DB-FF-CA1

nr

DB-FF-A1-1

nr

DB-FF-A1-2

nr

DB-FF-A1-3

nr

AA

DB-FF-A1-4
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

DB-FF-A1-5

nr

DB-FF-A1-6

nr

DB-FF-A1-7

nr

DB-FF-A1-8

nr

DB-FF-A1-9

nr

DB-FF-A1-10

nr

DB-FF-A1-11

nr

DB-FF-A1-12

nr

DB-FF-A1-13

nr

DB-FF-A1-14

nr

DB-FF-A1-15

nr

DB-FF-A1-16

nr

DB-FF-A1-17

nr

DB-GF-CA1

nr

DB-GF-A1-1

nr

DB-GF-A1-2

nr

DB-GF-A1-3

nr

DB-GF-A1-4

nr

DB-GF-A1-5

nr

DB-GF-A1-6

nr

DB-GF-A1-7

nr

DB-GF-A1-8

nr

DB-GF-A1-9

nr

DB-GF-A1-10

nr

AA

DB-GF-A1-11
Items as Part of Value Engineering (**)

nr

nr

Carried to Collection
A

DB-GF-A1-12

DB-GF-A1-13

nr

DB-GF-A1-14

nr

DB-GF-A1-15

nr

DB-CP-A1

nr

DB-FOH-A1

nr

DB-LG-PL1

nr

DB-HC1

nr

DB-GF-CH2

nr

DB-GH1

nr

DB-RH1

nr

DB-GF-DIN

nr

DB-GF-H2

nr

DB-PLBR

nr

ES-DB-CP-H2

nr

ES-DB-CP-H1

nr

ES-DB-GF-CH1

nr

ES-DB-FF-CH2

nr

ES-DB-FF-CH1

nr

ES-DB-SF-CH2

nr

ES-DB-SF-CH1

nr

ELDB-LGF-H2

nr

ELDB-LGF-H1

nr

AA

ELDB-LGF-A1
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

ELDB-LGF-A2

nr

ELDB-GF-H2

nr

ELDB-GF-H1

nr

ELDB-GF-A1

nr

ELDB-GF-A2

nr

ELDB-FF-H2

nr

ELDB-FF-H1

nr

ELDB-FF-A1

nr

ELDB-FF-A2

nr

ELDB-SF-H2

nr

ELDB-SF-H1

nr

ELDB-SF-A1

nr

ELDB-SF-A2

nr

ES-DB-FOH-A1

nr

ES-DB-HC (HEALTH CLUB)

nr

ES-DB-CP-A2

nr

ES-DB-FOH-A2

nr

ES-DB-CP-A1

nr

ES-DB-GF-CA2

nr

ES-DB-GF-CA1

nr

ES-DB-FF-CA2

nr

ES-DB-FF-CA1

nr

ES-DB-SF-CA2

nr

ES-DB-SF-CA1

nr

AA

UDB-IT
Items as Part of Value Engineering (**)

nr

Carried to Collection
A

UDB-SEC-1

nr

UDB-SEC-2

nr

ES-DB-GF-H2

nr

ES-DB-FP-2

nr

ES-DB-FOH-H1

nr

ES-DB-FOH-H2

nr

ES-DB-FOH-H3

nr

EDB-KIT1

nr

EDB-GF-KIT1

nr

Motor control center


Supply and installation of motor control center panels including circuit
breakers, electromechanical interlock, VFD, meters, cable trays/trunking
for final connections and steel mounting structure, complete; all in
accordance with the Drawings and Specification Section 619:0100
K

MCC-R1

nr

MCC-R2

nr

MCC-RA1

nr

MCC-RA2

nr

MCC-CHW-R

nr

MCC-RH2

nr

MCC-S/S

nr

MCC-BR

nr

ES-MCC-RH1

nr

ES-MCC-RH2

nr

ES-MCC-RA1

nr

ES-MCC-RA2

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

ES-MCC-LG-A1-1

nr

ES-MCC-LG-A1-2

nr

ES-MCC-LG-A1-3

nr

ES-MCC-LG-A1-4

nr

ES-MCC-LG-A2-1

nr

ES-MCC-LG-A2-2

nr

ES-MCC-LG-A2-3

nr

ES-MCC-LG-H2

nr

ES-MCC-BR

nr

ES-MCC-EX

nr

nr

Central Emergency Battery Panel


Supply and installation of central emergency battery panel including
battery, circuit breakers, electromechanical interlock, data bus cable,
containment for final connections and steel mounting structure,
complete; all in accordance with the Drawings and Specification Section
638:0100
L

28kVA Central battery panel


Control Panels
Supply and installation of motor control panels including circuit breakers,
electromechanical interlock, timers cable trays/trunking for final
connections and steel mounting structure, complete; all in accordance
with the Drawings and Specification Section 619:0100
Items as Part of Value Engineering (**)
Carried to Collection

Uninterruptible Power Supply Unit (UPS)


Supply and installation of uninterruptible power supply units (UPS)
including all necessary supports and fittings complete; all in accordance
with the Drawings and Specification Section 625:0100
W

80kVA UPS

nr

80kVA UPS-PANEL-1

nr

Isolator switch
Supply and installation of isolators including, electromechanical interlock,
final connections, cabling, containment and steel mounting structure,
complete; all in accordance with the Drawings and Specification Section
623:0100-0300
A

800A TPN Isolator

nr

400A TPN Isolator W/P

nr

200A TPN Isolator W/P

nr

160A TPN Isolator

nr

160A TPN Isolator W/P

nr

125A TPN Isolator W/P

nr

125A 4P Isolator, WP

nr

100A TPN Isolator

nr

100A TPN Isolator W/P

nr

80A TPN Isolator

nr

80A TPN Isolator W/P

10

nr

80A 4P Isolator W/P

17

nr

63A TPN Isolator

nr

63A TPN Isolator W/P

42

nr

63A 4P Isolator W/P

nr

40A TPN Isolator W/P

50

nr

40A 4P Isolator W/P

nr

32A SPN Isolator

nr

32A TPN Isolator

nr

32A TPN Isolator W/P

38

nr

32A 4P Isolator W/P

nr

Items as Part of Value Engineering (**)


Carried to Collection
A

25A TPN Isolator

nr

25A TPN Isolator W/P

nr

20A 4P Isolator

nr

20A 4P Isolator W/P

nr

16A SPN Isolator

23

nr

16A SPN Isolator, WP

nr

16A TPN Isolator W/P

21

nr

16A 4P Isolator W/P

15

nr

13A TPN Isolator

nr

13A SPN Isolator

nr

SPN Isolator

nr

Cable tray and trunking


Supply and installation of cable trays and trunking including all fittings,
supports, complete; all in accordance with the Drawings and
Specification Section 621:0100-0300
To Roof
M

100x35mm HDGI cable tray

231

150x35mm HDGI cable tray

284

200x35mm HDGI cable tray

16

225x35mm HDGI cable tray

21

300x35mm HDGI cable tray

185

600x60mm HDGI cable tray

24

900x85mm HDGI cable tray

97

600mm HDGI ladder

900mm HDGI ladder

43

Items as Part of Value Engineering (**)


Carried to Collection
To Internal
A

100x35mm HDGI cable tray

585

125x35mm HDGI cable tray

11

150x35mm HDGI cable tray

768

200x35mm HDGI cable tray

544

300x35mm HDGI cable tray

893

450x60mm HDGI cable tray

664

600x60mm HDGI cable tray

260

900x85mm HDGI cable tray

38

600mm HDGI ladder

100x100mm G.I. Trunking

361

75x75mm G.I. Trunking

51

50x50mm G.I. Trunking

3,400

1,330

uPVC Conduit
Supply and installation of electrical PVC conduit pipe inside the building
including bends and the like, complete; all in accordance with the
Drawings and Specification Section 621:0700
N

32mm uPVC pipe (**)


Ducts and Trenches
Supply and installation of electrical ducts and trenches inside the building
including excavation, beds and surrounds, backfilling and the like,

complete; all in accordance with the Drawings and Specification


P

Cable trench inside LV room, 1000mm width

22

Cable trench inside LV room, 800mm width

72

Cable trench inside transformer room, 1000mm width

15

Cable trench inside transformer room, 800mm width

32

Steel chequered plate G.I grating


Items as part of Value Engineering (**)

120

m2

Supply and installation of cables, laid in ducts, cable tray or trunking


(measured elsewhere) including connection to equipment as required,
complete; all in accordance with the Drawings and Specification Section
622:0100, 0500, 0700, 0800, 0900 and 1000
Cost diff. between armor and non armor ( **)
3C-300mm2/Cu/XLPE

141

15x1C-630mm2/XLPE/AWA

224

2x4C 300mm XLPE/SWA/PVC/CU + 2x1C 150mm ECC/PVC/CU

60

2x4C 300mm XLPE/SWA/PVC/CU + 1x1C 300mm ECC/PVC/CU

287

1x4C 300mm XLPE/SWA/PVC/CU + 1x1C 150mm ECC/PVC/CU

438

2x4C 240mm XLPE/SWA/PVC/CU + 1x1C 240mm ECC/PVC/CU

308

1x4C 240mm XLPE/SWA/PVC/CU + 1x1C 120mm ECC/PVC/CU

26

2x4C 185mm XLPE/SWA/PVC/CU + 1x1C 185mm ECC/PVC/CU

708

1x4C 185mm XLPE/SWA/PVC/CU + 1x1C 95mm ECC/PVC/CU

101

1x4C 150mm XLPE/SWA/PVC/CU + 1x1C 95mm ECC/PVC/CU

73

1x4C 120mm XLPE/SWA/PVC/CU + 1x1C 70mm ECC/PVC/CU

343

1x4C 95mm XLPE/SWA/PVC/CU + 1x1C 50mm ECC/PVC/CU

137

1x4C 70mm XLPE/SWA/PVC/CU + 1x1C 35mm ECC/PVC/CU

86

1x4C 50mm XLPE/SWA/PVC/CU + 1x1C 25mm ECC/PVC/CU

594

Carried to Collection
Cables

1x4C 35mm XLPE/SWA/PVC/CU + 1x1C 16mm ECC/PVC/CU

883

1x4C 25mm XLPE/SWA/PVC/CU + 1x1C 16mm ECC/PVC/CU

2,437

1x4C 16mm XLPE/SWA/PVC/CU + 1x1C 16mm ECC/PVC/CU

8,261

1x4C 10mm XLPE/SWA/PVC/CU + 1x1C 10mm ECC/PVC/CU

3,012

1x4C 6mm XLPE/SWA/PVC/CU + 1x1C 6mm ECC/PVC/CU

994

1x4C 4mm XLPE/SWA/PVC/CU + 1x1C 4mm ECC/PVC/CU

43

1X2C 6mm XLPE/SWA/PVC/CU + 1x1C 6mm ECC/PVC/CU

4,604

Items as part of Value Engineering (**)


Carried to Collection
A

2x4C 300mm FRT/SWA/LSF/CU + 1x1C 300mm ECC/LSF/CU

83

2x4C 240mm FRT/SWA/LSF/CU + 1x1C 240mm ECC/LSF/CU

79

2x4C 185mm FRT/SWA/LSF/CU + 1x1C 185mm ECC/LSF/CU

294

1x4C 185mm FRT/SWA/LSF/CU + 1x1C 95mm ECC/LSF/CU

126

1x4C 150mm FRT/SWA/LSF/CU + 1x1C 70mm ECC/LSF/CU

437

1x4C 120mm FRT/SWA/LSF/CU + 1x1C 70mm ECC/LSF/CU

329

1x4C 95mm FRT/SWA/LSF/CU + 1x1C 50mm ECC/LSF/CU

173

1x4C 70mm FRT/SWA/LSF/CU + 1x1C 35mm ECC/LSF/CU

132

1x4C 50mm FRT/SWA/LSF/CU + 1x1C 25mm ECC/LSF/CU

482

1x4C 35mm FRT/SWA/LSF/CU + 1x1C 16mm ECC/LSF/CU

637

1x4C 25mm FRT/SWA/LSF/CU + 1x1C 16mm ECC/LSF/CU

1,023

1x4C 16mm FRT/SWA/LSF/CU + 1x1C 16mm ECC/LSF/CU

393

1x4C 10mm FRT/SWA/LSF/CU + 1x1C 10mm ECC/LSF/CU

880

1x4C 6mm FRT/SWA/LSF/CU + 1x1C 6mm ECC/LSF/CU

1,051

1x4C 4mm FRT/SWA/LSF/CU + 1x1C 4mm ECC/LSF/CU

27

1x2C 10mm FRT/SWA/LSF/CU + 1x1C 10mm ECC/LSF/CU

15

1x2C 4mm FRT/SWA/LSF/CU + 1x1C 4mm ECC/LSF/CU

17

Bus bar
Supply and installation of bus bar including connections, terminations,
fixings, fittings, and the like, complete; all in accordance with the
Drawings and Specification Section 622:1200
T

BB-H2, 2500A TPN+E, 50kA, 5 Pole Cu. Bus Bar

131

BB-A1, 2500A TPN+E, 50kA, 5 Pole Cu. Bus Bar

136

BB-A2, 2250A TPN+E, 50kA, 5 Pole Cu. Bus Bar

205

BB-01, 2000A TPN+E, 50kA, 5 Pole Cu. Bus Bar

119

BB-02, 2000A TPN+E, 50kA, 5 Pole Cu. Bus Bar

117

Items as part of Value Engineering (**)


Carried to Collection
A

BB-MDB-02, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

12

BB-ESMDB-A, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

11

BB-EMDB-02, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

BB-H1, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

85

BB-MDB-06, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

14

BB-ESMDB-H, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

12

BB-EMDB-01, 1800A TPN+E, 50kA, 5 Pole Cu. Bus Bar

13

Bus bar tap off units


Supply and installation and connect bus bar tap off units including fittings
and supports, and the like, complete; all in accordance with the Drawings
and Specification
H

500A TPN MCCB 50kA

11

nr

400A TPN MCCB 50kA

nr

350A TPN MCCB 50kA

nr

300A TPN MCCB 50kA

nr

160A TPN MCCB 50kA

nr

100A TPN MCCB 50kA

nr

63A TPN MCCB 50kA

nr

1,591

nr

94

nr

2,677

nr

nr

1,802

nr

Final sub circuits and auxiliary installations


Supply and installation of the final circuits for the following items,
including conduits and cables, complete; all in accordance with the
Drawings and Specification Section 621:0200-1000 and 622:0200-1000
Accessories
To Socket outlets
Q

13A Single Switched Socket Outlet (qty 140 to be corrected) (**)

13A Single Switched Socket Outlet W/P

13A Twin Switched Socket Outlet (qty 1,440 to be corrected) (**)


Items as part of Value Engineering (**)
Carried to Collection

13A Twin Switched Socket Outlet W/P

13A Switched Fused Spur Outlet With Neon Indicator (**)

13A Switched Fused Spur Outlet With Neon Indicator W/P

54

nr

13A Unswitched Fused Spur Outlet With Neon Indicator (**)

263

nr

FB1, 2 compartment flushed floor box with 2x13A single switched socket
outlet

11

nr

FB2, 2 compartment flushed floor box with 1x13A single switched socket
outlet + 1xvoice/data outlet

28

nr

FB3, 3 compartment flushed floor box with 2x13A single switched socket
outlet + 1xvoice/data + 1xvoice outlet

nr

FB4, 3 compartment flushed floor box with 2x13A single switched socket
outlet + 1xtwin voice/data + 1xtwin voice outlet

10

nr

FB5, 2 compartment flushed floor box with 1x13A single switched socket
outlet + 2xtwin voice/data outlet

nr

FB6, 3 compartment flushed floor box with 2x13A single switched socket

nr

outlet + 2xtwin voice/data outlet


L

5A socket for table/bedside/floor/des/console lights

889

nr

13A single unswitched socket outlet

312

nr

Flex outlet for CCU (+140 for W/D) (**)

140

nr

32A/45A DP switch with neon (CCU) (+140 for W/D) (**)

140

nr

20A DP switched with neon indicator (**)

377

nr

Hand dryer, 20A switch

nr

220/110V AC Shaver outlet

257

nr

32A SP+N+E switched socket outlet

nr

16A TP+N+E 5 pin switched socket outlet

10

nr

J, Junction box for kitchen and restaurant (**)

186

nr

J, Junction box for night lights

111

nr

J, Junction box for wardrobe light


Items as part of Value Engineering (**)

180

nr

1,172

nr

nr

1,433

nr

Carried to Collection
To Switches
A

Single Pole One Way Switch One Gang

Single Pole One Way Switch One Gang, WP

Single Pole One Way Switch Two Gang

Single Pole One Way Switch Two Gang, WP

nr

Single Pole Two Way Switch Three Gang

nr

Single Pole Two Way Switch Four Gang

nr

Single Pole Two Way Switch Five Gang

nr

Single Pole Two Way Switch One Gang

nr

Single Pole Two Way Switch One Gang, WP

nr

Single Pole Two Way Switch Two Gang, WP

nr

Presence sensor - surface/trunking mounted

159

nr

Presence sensor - ceiling reccessed

120

nr

Time delay push button switch

nr

1,591

nr

94

nr

2,677

nr

nr

Supply and installation of the following accessories, complete; including


final wiring all in accordance with the Drawings and Specification Section
623:0100
Socket outlets
P

13A Single Switched Socket Outlet (qty 140 for Oven) (**)

13A Single Switched Socket Outlet W/P

13A Twin Switched Socket Outlet 9qty 1440 ONU in apart (**)

13A Twin Switched Socket Outlet W/P

13A Switched Fused Spur Outlet With Neon Indicato (**)

1,802

nr

13A Switched Fused Spur Outlet With Neon Indicator W/P

54

nr

13A Unswitched Fused Spur Outlet With Neon Indicator (**)

263

nr

Items as part of Value Engineering (**)


Carried to Collection
A

FB1, 2 compartment flushed floor box with 2x13A single switched socket
outlet

11

nr

FB2, 2 compartment flushed floor box with 1x13A single switched socket
outlet + 1xvoice/data outlet

28

nr

FB3, 3 compartment flushed floor box with 2x13A single switched socket
outlet + 1xvoice/data + 1xvoice outlet

nr

FB4, 3 compartment flushed floor box with 2x13A single switched socket
outlet + 1xtwin voice/data + 1xtwin voice outlet

10

nr

FB5, 2 compartment flushed floor box with 1x13A single switched socket
outlet + 2xtwin voice/data outlet

nr

FB6, 3 compartment flushed floor box with 2x13A single switched socket
outlet + 2xtwin voice/data outlet

nr

5A socket for table/bedside/floor/des/console lights

889

nr

13A single unswitched socket outlet

312

nr

Flex outlet for CCU (**)

140

nr

32A/45A DP switch with neon (CCU) (**)

140

nr

20A DP switched with neon indicator (**)

377

nr

Hand dryer, 20A switch

nr

220/110V AC Shaver outlet

257

nr

32A SP+N+E switched socket outlet

nr

16A TP+N+E 5 pin switched socket outlet

10

nr

J, Junction box for kitchen and restaurant (**)

186

nr

J, Junction box for night lights

111

nr

J, Junction box for wardrobe light

180

nr

Switches
U

Single Pole One Way Switch One Gang (**)

1,172

nr

Single Pole One Way Switch One Gang, WP

nr

Single Pole One Way Switch Two Gang (**)

1,433

nr

Items as part of Value Engineering (**)


Carried to Collection
A

Single Pole One Way Switch Two Gang, WP

nr

Single Pole Two Way Switch Three Gang

nr

Single Pole Two Way Switch Four Gang

nr

Single Pole Two Way Switch Five Gang

nr

Single Pole Two Way Switch One Gang

nr

Single Pole Two Way Switch One Gang, WP

nr

Single Pole Two Way Switch Two Gang, WP

nr

Presence sensor - surface/trunking mounted

159

nr

Presence sensor - ceiling reccessed

120

nr

Time delay push button switch

nr

Final sub circuits and auxiliary installations


Supply and installation of the final circuits for the following items,
including conduits and cables, complete; all in accordance with the
Drawings and Specification Section 621:0200-1000 and 622:0200-1000
To BOH and other areas
L

A1 - 4X14W T5 Lamp Recessed Fluorescent Lumina ire Complete With


High Frequency Control Gear, Double Parabolic Louvre, IP20 Rating

152

nr

A2 - 4X14W T5 Lamp Recessed Fluorescent Lumina ire Complete With


High Frequency Control Gear, Double Parabolic Louvre, IP44 Rating

221

nr

B1 - 1X28W T5 Linear Fluorescent Light, Single Lamp,IP65 Rating


(Ceiling, Surface Mounted)

76

nr

B2 - 2X35W T5 Linear Fluorescent Light, Double Lamp,IP65 Rating


(Ceiling, Surface Mounted)

440

nr

Ref. B3 to AV and sound equipment storage at lower ground

nr

C1 - 23W LED Circular Surface, Ceiling Mounted Down Light, IP65


Rating

12

nr

D1 - 24W LED 192 x 99mm Recessed Down light Rated IP20

170

nr

D2 - 24W LED 192 x 99mm Recessed Down light Rated IP44

nr

Items as part of Value Engineering (**)


Carried to Collection
A

D3 - 18W LED 82 x 100mm Recessed Down light Rated IP65

27

nr

D5 - LED Recessed Down light at lower ground locker

nr

G - Recessed Down light Led 7W / 3000K / 350Ma-Dc / 33 Deltalight

nr

LT1, ligth fitting to ground floor male/female and prayer room

36

nr

M1 - 1x14W T5, 4000K flourescent rated IP44 toilet mirror light, surface
mounted extended aluminium housing and end caps

nr

P - Lighting to lower ground toilets and pantry

80

nr

TT - Recessed downlight LED 8W/230Vac 3000K/20 white

86

nr

U - Ceiling Recessed Adjustable 45/355 LED Light 7W / 3000K /


350Ma-Dc Deltalight

14

nr

W - Ceiling Recessed Adjustable 45/355 Led Light 2W / 3000K /


350Ma-Dc Deltalight

nr

WB1 - 28W LED Compact Fluorescent Lamps Surface Mounted Light


Fitting IP65 rating

80

nr

WL1 - 2X18W T8 Light Fitting Wall Mounted Rated IP65 (For Ramp
Lighting)

50

nr

WL2 - 1X28W 2D T5 Light Fitting Surface Mounted Rated IP65 (Forklift


shaft)

14

nr

To Corridors
N

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

392

nr

H - Recessed downlight LED 7W/500mA / 4000K

216

nr

To Executive Lounge
Q

LT-EL-02 - Pendant light

nr

LT-EL-03 - Pendant light

nr

LT-EL-04 - Pendant light

nr

LT-EL-05 - Pendant light

72

nr

LT-EL-06 - Pendant light

nr

LT-EL-07 - Linear LED strip light


Items as part of Value Engineering (**)

nr

Carried to Collection
A

LT-EL-08 - Pendant light

19

nr

LT-EL - Pendant light on skylight

nr

nr

To All Day Dinning


C

LT-ADD-01 - Pendant light

LT-ADD-02 - Pendant light

20

nr

LT-ADD-04 - Pendant light

nr

LT-ADD-05 - Pendant light

16

nr

LT-ADD - Pendant light on dinning area

nr

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

18

nr

H - Recessed downlight LED 7W/500mA / 4000K

59

nr

To Reception Lobby
K

LT-RL-01 - Console light

nr

LT-RL-02 - Console light

11

nr

LT-RL-03 - Pendant light

140

nr

LT-RL-05 - Pendant light

nr

LT-RL-06 - Pendant light

nr

LT-RL - Pendant light on lobby lounge table

nr

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

28

nr

H - Recessed downlight LED 7W/500mA / 4000K

62

nr

To Security Pod
T

LT-SP-01 - Pendant light

28

nr

LT-SP-02 - Linear LED strip light

nr

LT-SP-03 - Floor lamp

nr

nr

To Ball Room
W

LT-BR-01 - Chandelier
Items as part of Value Engineering (**)
Carried to Collection

LT-BR-02 - Linear LED strip light

22

nr

LT-SP-03 - Pendant light

183

nr

LT-BR-04 - Pendant light

41

nr

To Chreche and Residents Lounge


D

LT-CP-01 - Floor lamp

nr

LT-CP-02 - Pendant light

36

nr

H - Recessed downlight LED 7W/500mA / 4000K

47

nr

To Meeting Suites
G

LT-MS-01 - Pendant light

72

nr

LT-MS-02 - Pendant light

nr

LT-MS-03 - Pendant light

nr

LT-MS-04 - Pendant light

12

nr

LT-MS-05 - Pendant light

12

nr

LT-MS-06 - Pendant light

13

nr

LT-MS-07 - Pendant light

103

nr

LT-MS-08 - Linear LED strip light

16

nr

LT-MS-09 - Pendant light

nr

To MEA Reception
R

LT-MEA-01 - Table lamp

nr

LT-MEA - Pendant light

47

nr

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

nr

nr

To Health and Fitness Suites


U

LT-HF-05 - Pendant light

Pendant light

236

nr

Linear LED strip light


Items as part of Value Engineering (**)

19

nr

36

nr

Carried to Collection
A

Lobby corridor pendant light

To Double room
B

LT-GR-01 - Down lights LED

44

nr

LT-GR-02 - Down lights LED

66

nr

LT-GR-10/201 - Pendant light

22

nr

LT-GR-09 - LED strip light

44

nr

LT-GR-301 - Wall mounted reading light

44

nr

To King room
G

LT-GR-01 - Down lights LED

106

nr

LT-GR-02 - Down lights LED

153

nr

LT-GR-10/201 - Pendant light

51

nr

LT-GR-09 - LED strip light

100

nr

LT-GR-301 - Wall mounted reading light

102

nr

To Suite
M

LT-GR-01 - Down lights LED

32

nr

LT-GR-02 - Down lights LED

41

nr

LT-GR-04 - Pendant light

nr

LT-GR-05 - Pendant light

nr

LT-GR-09 - LED strip light

10

nr

LT-GR-301 - Wall mounted reading light

14

nr

To VIP
T

LT-VP-01 - Down lights LED

nr

LT-VP-02 - Down lights LED

nr

LT-VP-03 - Credenza light

nr

LT-VP-04 - Pendant light


Items as part of Value Engineering (**)

nr

Carried to Collection
A

LT-VP-05 - Pendant light

nr

LT-VP-06 - Dressing light

nr

LT-VP-08 - Office cabinet light

nr

LT-VP-101 - Pendant over dinning

nr

LT-VP-101 - Pendant over living

nr

LT-VP-09 - LED strip light

nr

LT-VP-301 - Wall mounted reading light

nr

To One Bed Apartment


H

LT-AP-01 - Down lights LED

701

nr

LT-AP-02 - Down lights LED

610

nr

LT-AP-03 - Pendant light

324

nr

LT-AP-04 - Pendant light

109

nr

LT-AP-05 - Pendant light

nr

LT-AP-09 - LED strip light

216

nr

LT-AP-11 - Wall mounted reading light

216

nr

To Two Bed Apartment


Q

LT-AP-01 - Down lights LED

217

nr

LT-AP-02 - Down lights LED

184

nr

LT-AP-03 - Pendant light

39

nr

LT-AP-04 - Pendant light

22

nr

LT-AP-05 - Pendant light

nr

LT-AP-09 - LED strip light

49

nr

LT-AP-11 - Wall mounted reading light

88

nr

To Three Bed Apartment

LT-AP-01 - Down lights LED


Items as part of Value Engineering (**)

214

nr

Carried to Collection
A

LT-AP-02 - Down lights LED

109

nr

LT-AP-03 - Pendant light

13

nr

LT-AP-04 - Pendant light

17

nr

LT-AP-05 - Pendant light

10

nr

LT-AP-09 - LED strip light

47

nr

LT-AP-11 - Wall mounted reading light

60

nr

To Exterior Lighting
G

DD - Recessed uplight LED 2W/500mA/3000K IP67

22

nr

EE1 - Recessed floor LED light 10W/230V/10/3000K IP68 plate 1200


mini

69

nr

EE2 - Recessed floor LED light 10W/230V/30/3000K IP68 plate 1200


mini

28

nr

EE2 - Recessed floor LED light 10W/230V/50/3000K IP68 plate 1200


mini

nr

GG - Recessed linear LED strip 9.2W/Lm/3000K + aluminium profile


with opaline diffuser QBO - Trailed flexy HO + profile Z201-2

282

nr

nr

To Lift Car
M

Q - Recessed aluminum profile + LED 14.4W/Lm/3000K 24Vdc QBO profile Z201-1 + tiraled flexi
To Emergency Lighting

E1 - 1X8W Addressable emergency Lumina ire -IP20 [recess mounted]

122

nr

E2 - 1X8W Addressable emergency Lumina ire - IP65 [surface mounted]

223

nr

E3 - 1X11W Addressable emergency Lumina ire - IP65 [surface


mounted]

167

nr

E4 - 4X1W LED addressable emergency Lumina ire - IP20 [recessed


mounted]

635

nr

E5 - 9X1.5W LED Emergency Lumina ire ceiling recessed type, IP44

16

nr

E7 - 1X8W, T5, emergency lighting fixture, IP65 (recessed mounted)

38

nr

Items as part of Value Engineering (**)


Carried to Collection
A

EX1 - LED strip addressable maintained exit Lumina ire IP20 [ceiling
mounted]

100

nr

EX2 - LED strip addressable maintained exit Lumina ire IP65 [surface
mounted]

90

nr

EX3 - LED strip addressable maintained exit Lumina ire IP65 [ceiling
mounted]

38

nr

EX4 - LED strip addressable maintained exit Lumina ire IP65 [surface
mounted]

74

nr

Light fittings
Supply and installation of the following light fittings, complete; all in
accordance with the Drawings and Specification Section 631:0100-0200
BOH and other areas
E

A1 - 4X14W T5 Lamp Recessed Fluorescent Lumina ire Complete With


High Frequency Control Gear, Double Parabolic Louvre, IP20 Rating

152

nr

A2 - 4X14W T5 Lamp Recessed Fluorescent Lumina ire Complete With


High Frequency Control Gear, Double Parabolic Louvre, IP44 Rating

221

nr

B1 - 1X28W T5 Linear Fluorescent Light, Single Lamp,IP65 Rating


(Ceiling, Surface Mounted)

76

nr

B2 - 2X35W T5 Linear Fluorescent Light, Double Lamp,IP65 Rating


(Ceiling, Surface Mounted)

440

nr

Ref. B3 to AV and sound equipment storage at lower ground

nr

C1 - 23W LED Circular Surface, Ceiling Mounted Down Light, IP65


Rating

12

nr

D1 - 24W LED 192 x 99mm Recessed Down light Rated IP20

170

nr

D2 - 24W LED 192 x 99mm Recessed Down light Rated IP44

nr

D3 - 18W LED 82 x 100mm Recessed Down light Rated IP65

27

nr

D5 - LED Recessed Down light at lower ground locker

nr

G - Recessed Down light Led 7W / 3000K / 350Ma-Dc / 33 Deltalight

nr

LT1, ligth fitting to ground floor male/female and prayer room

36

nr

Items as part of Value Engineering (**)


Carried to Collection
A

M1 - 1x14W T5, 4000K flourescent rated IP44 toilet mirror light, surface
mounted extended aluminium housing and end caps

nr

P - Lighting to lower ground toilets and pantry

80

nr

TT - Recessed downlight LED 8W/230Vac 3000K/20 white

86

nr

U - Ceiling Recessed Adjustable 45/355 LED Light 7W / 3000K /


350Ma-Dc Deltalight

14

nr

W - Ceiling Recessed Adjustable 45/355 Led Light 2W / 3000K /


350Ma-Dc Deltalight

nr

WB1 - 28W LED Compact Fluorescent Lamps Surface Mounted Light


Fitting IP65 rating

80

nr

WL1 - 2X18W T8 Light Fitting Wall Mounted Rated IP65 (For Ramp
Lighting)

50

nr

WL2 - 1X28W 2D T5 Light Fitting Surface Mounted Rated IP65 (Forklift


shaft)

14

nr

2,350

216

nr

22

Corridors
J

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

H - Recessed downlight LED 7W/500mA / 4000K


To Executive Lounge

LT-EL-07 - Linear LED strip light


All Day Dinning

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

107

H - Recessed downlight LED 7W/500mA / 4000K

59

nr

Reception Lobby
N

UU - Recessed Linear LED strip 19.2W/Lm / 3000K

113

H - Recessed downlight LED 7W/500mA / 4000K

62

nr

17

213

47

nr

262

16

100

Security Pod
R

LT-SP-02 - Linear LED strip light


Ball Room

LT-BR-02 - Linear LED strip light


Items as part of Value Engineering (**)
Carried to Collection
Chreche and Residents Lounge

H - Recessed downlight LED 7W/500mA / 4000K


Meeting Suites

LT-MS-08 - Linear LED strip light

MEA Reception
Q

UU - Recessed Linear LED strip 19.2W/Lm / 3000K


Health and Fitness Suites

Linear LED strip light


Double room

LT-GR-01 - Down lights LED

44

nr

LT-GR-02 - Down lights LED

66

nr

LT-GR-09 - LED strip light

175

King room
E

LT-GR-01 - Down lights LED

106

nr

LT-GR-02 - Down lights LED

153

nr

LT-GR-09 - LED strip light

395

Suite
K

LT-GR-01 - Down lights LED

32

nr

LT-GR-02 - Down lights LED

41

nr

LT-GR-09 - LED strip light

45

VIP
R

LT-VP-01 - Down lights LED

nr

LT-VP-02 - Down lights LED

nr

LT-VP-03 - Credenza light

nr

Items as part of Value Engineering (**)


Carried to Collection

LT-VP-09 - LED strip light


One Bed Apartment

LT-AP-01 - Down lights LED

701

nr

LT-AP-02 - Down lights LED

610

nr

LT-AP-09 - LED strip light

760

Two Bed Apartment


M

LT-AP-01 - Down lights LED

217

nr

LT-AP-02 - Down lights LED

184

nr

LT-AP-09 - LED strip light

309

Three Bed Apartment


U

LT-AP-01 - Down lights LED

214

nr

LT-AP-02 - Down lights LED

109

nr

LT-AP-09 - LED strip light

227

Exterior Lighting

DD - Recessed uplight LED 2W/500mA/3000K IP67

22

nr

EE1 - Recessed floor LED light 10W/230V/10/3000K IP68 platek 1200


mini

69

nr

EE2 - Recessed floor LED light 10W/230V/30/3000K IP68 platek 1200


mini

28

nr

EE2 - Recessed floor LED light 10W/230V/50/3000K IP68 platek 1200


mini

nr

GG - Recessed linear LED strip 9.2W/Lm/3000K + aluminium profile


with opaline diffuser QBO - Trailed flexy HO + profile Z201-2

1,985

35

Lift Car
J

Q - Recessed aluminum profile + LED 14.4W/Lm/3000K 24Vdc QBO profile Z201-1 + tiraled flexi

Items as part of Value Engineering (**)


Carried to Collection
Emergency and exit light fittings
Emergency and exit lighting fixtures, including final wiring, cables,
conduits, connections, terminations, fixings, fittings, and the like,
complete; in accordance with the Drawings and Specification
A

E1 - 1X8W Addressable emergency luminaire -IP20 [recess mounted]

122

nr

E2 - 1X8W Addressable emergency luminaire - IP65 [surface mounted]

223

nr

E3 - 1X11W Addressable emergency luminaire - IP65 [surface mounted]

167

nr

E4 - 4X1W LED addressable emergency luminaire - IP20 [recessed


mounted]

635

nr

E5 - 9X1.5W LED Emergency luminaire ceiling recessed type, IP44

16

nr

E7 - 1X8W, T5, emergency lighting fixture, IP65 (recessed mounted)

38

nr

EX1 - LED strip addressable maintained exit luminaire IP20 [ceiling


mounted]

100

nr

EX2 - LED strip addressable maintained exit luminaire IP65 [surface


mounted]

90

nr

EX3 - LED strip addressable maintained exit luminaire IP65 [ceiling


mounted]

38

nr

EX4 - LED strip addressable maintained exit luminaire IP65 [surface


mounted]

74

nr

Supply, install, test, commission and maintain complete Earthing and


Lightning Protection System in accordance with the Drawings and
Specifications Section 671:0100-0500, but not necessarily limited to the
following :
Cost diff. between armour and non-armour cable (**)
1 x 1C 25 mm2 Cu./PVC earth cable (**)

90

1 x 1C 70 mm2 Cu./PVC earth cable (**)

825

1 x 1C 95mm2 Cu/ PVC earth cable (**)

25

1 x 1C 150mm2 Cu/ PVC earth cable (**)

425

100mm diameter PVC conduit

146

Earthing and Grounding System

Items as part of Value Engineering (**)


Carried to Collection
Ground bus bar with porcelain isolator, 50 x 6mm thick, complete as
shown on drawings
A

Earth bar in Generator room

nr

Earth bar in electrical room

nr

Earth bar for EMDB

nr

Earth bar for MDB -1 to MDB -6

nr

Earth bar for MV panel-1 and 2

nr

Earth bar for transformer -1-6

nr

Earth bar for UPS

nr

Earth bar for GSM

nr

Earth bar for MDF room

nr

Earth bar for IT rooms

14

nr

Earth bar for TEL. Intake

nr

Earthing pit with 16mm earth rod electrode minimum 3.60m long
including connection to 95mm bare copper wire, connection rod to
conductor, test point, waterproofing and other accessories, complete
M

Earth pit, EP-TEL

nr

Earth pit, EP-IT

nr

Earth pit, EP-GSM

nr

Earth pit, EP-UPS

nr

Earthing pit with 16mm earth rod electrode minimum 3.60m long
including connection to 150mm bare copper wire, connection rod to
conductor, test point, waterproofing and other accessories, complete
R

Earth pit, EP-IR

nr

Earth pit, EP-GP

nr

Earth pit, EP-SR

nr

Earth pit, EP-TX

12

nr

Items as part of Value Engineering (**)


Carried to Collection
A

Earth pit, EP-LV

12

nr

Earth pit, EP-EM

nr

Allow for other miscellaneous work in connection with the earthing and
lightning protection systems (**)

item

Allow for earthing and bonding to architectural panels, structural steel (**)
works and the like (**)

item

Items as part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.6
5H: ELECTRICAL INSTALLATIONS
COLLECTION

Page No
-269-

Total Brought Forward from Page No.

-270-271-272-273-274-275-276-277-278-279-280-281-282-283-284-285-286-287Carried Forward
Section No.6
SERVICES
Bill No.6

5H: ELECTRICAL INSTALLATIONS


COLLECTION
Page No

-288-

Total Brought Forward from Page No.

-289-290-291-292-293-294-295-296-297-298-299-300-301-302-303-304-305Carried Forward
Section No.6
SERVICES

Bill No.6
5H: ELECTRICAL INSTALLATIONS
COLLECTION
Page No

Total Brought Forward from Page No.

-306-307-308-309-310-311-312-313-314-

Carried Forward to Summary of Section No. 6

5I: GAS INSTALLATIONS


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

LPG PIPE WORK


PIPE WORK
PIPE WORK measured including fittings and support
Supply and installation of carbon steel schedule 80 PIPE WORK
including all necessary accessories, fittings, supports, labelling and the
like, complete; all in accordance with the Drawings and Specification
Section 503.4900
To Kitchen area distribution line
A

20mm diameter

31

25mm diameter

80

32mm diameter for LPG filling line

35

65mm diameter for distribution line

218

117

Supply and installation of flue gas exhaust duct including all necessary
accessories, insulation, fittings, supports, labelling and the like, complete;
all in accordance with the Drawings and Specification Section 503.4900
E

400mm diameter
Pipe specialties
Supply and installation of LPG pipe specialties including all accessories,
fittings and supports, complete; all in accordance with the Drawings and
Specification

Isolating valve, 20mm diameter

nr

Isolation valve, 65mm diameter

nr

Items as part of Value Engineering (**)


Carried to Collection
Supply and installation of filling point with power coated aluminium box
with wired glass front door including double check valve, globe valve, cap
for fill connection,16mm earth cable & conduit , complete; all in
accordance with the Drawings and Specification
A

32mm diameter filling point

nr

nr

nr

Supply and installation of LPG changeover regulation and distribution


panel including solenoid valve, first stage regulator, manual shut off
valve etc. complete; all in accordance with the Drawings and
Specification Section 503.4900
B

Pressure Reducing Distribution Panel


Supply and installation of Distribution Box including solenoid valve, ball
valve, gas meter and regulator complete; all in accordance with the
Drawings and Specification Section 503.4900

Distribution Box with break glass locking device


Equipment
Supply and installation of following LPG equipments, complete; all in
accordance with the Drawings and Specification Section 503.4903

LPG storage tank 1500 Litre capacity including fill valve, excess flow
valve, outlet valve pressure gauge, liquid level gauge, pressure relief
valve, back check adapter, drain plug, LPG leak detector, check lock,
service valve, first stage pressure regulator, liquid transfer valve, ARV,
DC drain and name plate; complete; all in accordance with the Drawings
and Specification Section 503.4903

nr

Gas meter, as specified

item

Vaporizer

nr

109

GAS LEAK DETECTION SYSTEM


Ducts
Supply and installation of steel duct containment to gas distribution pipes
, fittings, supports and accessories complete; all in accordance with the
Drawings and Specification Section 503.4900
G

65mm diameter

100mm diameter

179

Items as part of Value Engineering (**)


Carried to Collection
Final sub circuits and auxiliary installations
Supply and installation of final circuits for the following items including
conduits and cables, complete; all in accordance with the Drawings and
Specification Section 503.4910
A

Gas leakage detection panel

nr

Emergency shut of push button

nr

Gas detector

14

nr

Gas detector explosion proof

nr

Sounder

nr

Accessories
Supply and installation of LPG leak detection system, complete; all in
accordance with the Drawings and Specification Section 503.4910
F

Gas leakage detection panel

nr

Gas detector

14

nr

Gas detector explosion proof

nr

Emergency shut of push button

nr

Sounder

nr

Extra over connection


L

Allow for the final connection to gas fired calorifier including flexible hose,
valves, fittings, reducers and fixing, complete.

item

Allow interface with fire alarm system

item

FIRE PROTECTIVE SYSTEM FOR LPG


PIPE WORK
Supply and installation of GI seamless PIPE WORK above ground,

including all necessary supports, fittings, couplings, markings, painting


materials, fire stops, consumables and the like, complete; all in
accordance with the Drawings and Specification Section 503.4913
N

Fire Fighting Pipe (**)

item

Items as part of Value Engineering (**)


Carried to Collection
Fire fighting pipe specialties
Supply and installation of fire fighting pipe specialties including all
necessary fixings and accessories, complete; all in accordance with the
Drawings and Specification
A

Solenoid Valve (**)

nr

Sprinkler system valve box (**)

nr

Equipment
Supply and installation of the fire fighting components, complete; all in
accordance with the Drawings and Specification
C

Open type sprinkler head (**)

nr

Sprinkler heads with fusible element (**)

nr

item

Extra over connection


E

Allow for the supply and installation of pre action deluge system served
from the building fire sprinkler system for the fire fighting provision of the
LPG containers, complete (**)

Items as part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.7
5I: GAS INSTALLATIONS
COLLECTION
Page No
Total Brought Forward from Page No.

-318-319-320-321-

Items as part of Value Engineering (**)


Carried Forward to Summary of Section No. 6

5J: LIFT AND CONVEYOR INSTALLATIONS


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

LIFTS
Passenger Lifts
Supply and installation of passenger lifts with heavy duty automatic
doors, full protection non contact door protection, microprocessor fully
collective group control, dot matrix car position indicator, group control /
simplex, centre opening, machine room less, complete; in accordance
with the Drawings and Specification Section 142100
A

Lift - HP1, size 2100 x 1600 x 2500mm high, 3nr stops, ground to level 2,
21 persons, 1600kg, 1.75m/s

nr

Lift - HP2, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2, 21 persons, 1600kg, 1.75m/s

nr

Lift - PP1, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2, 21 persons, 1600kg, 1.75m/s

nr

Lift - PP2, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2, 21 persons, 1600kg, 1.75m/s

nr

Lift - PP3, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2, 21 persons, 1600kg, 1.75m/s

nr

Lift - PP4, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to

nr

level 2, 21 persons, 1600kg, 1.75m/s


Supply and installation of hydraulic lifts, including twin plunger without
bore hole; simplex control, centre opening; in accordance with the
Drawings and Specification Section 142100
G

Circular panoramic lift, size 2000mm diameter x 2300mm high, 2nr stops,
lower ground and ground, 26 persons, 2000kg, 0.5m/s

nr

Items as part of Value Engineering (**)


Carried to Collection
Service Lifts
Supply and installation of service lifts, including heavy duty automatic
doors, full protection non contact door protection, microprocessor fully
collective group control, and dot matrix car position indicator; group
control / simplex; centre opening; machine room less, complete; in
accordance with the Drawings and Specification Section 142100
A

Lift - S1, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
level 3, 26 persons, 2000kg, 1.0m/s

nr

Lift - S2, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
level 3, 26 persons, 2000kg, 1.0m/s

nr

Lift - S3, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
level 3, 26 persons, 2000kg, 1.0m/s

nr

Lift - S4, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
level 3, 26 persons, 2000kg, 1.0m/s

nr

Items as part of Value Engineering (**)


Carried to Collection

LIFT FIT-OUT
Passenger Lift Car
Supply and installation of lift car fitout including landing architraves,
complete; all in accordance with the Drawings and Specification Section
142713
A

Lift - HP1, size 2100 x 1600 x 2500mm high, 3nr stops, ground to level 2

nr

Lift - HP2, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2

nr

Lift - PP1, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2

nr

Lift - PP2, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2

nr

Lift - PP3, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2

nr

Lift - PP4, size 2100 x 1600 x 2500mm high, 4nr stops, lower ground to
level 2

nr

Service Lift Car


Supply and installation of lift car fitout including landing architraves,

complete; all in accordance with the Drawings and Specification Section


142713
G

Lift - S1, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
roof

nr

Lift - S2, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
roof

nr

Lift - S3, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
roof

nr

Lift - S4, size 1500 x 2700 x 2900mm high, 5nr stops, lower ground to
roof

nr

Items as part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES
Bill No.8
5J: LIFT AND CONVEYOR INSTALLATIONS
COLLECTION
Page No
Total Brought Forward from Page No.

-323-324-325-

Items as part of Value Engineering (**)


Carried Forward to Summary of Section No. 6

5K: PROTECTIVE INSTALLATIONS


Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

FIRE FIGHTING SERVICES


Pipe work
Supply and installation of blacksteel EWR schedule 40 Pipe work above
ground, including all necessary supports, fittings, couplings, markings,
painting materials, fire stops, consumables, cuttings, mortices, chases,
identifications, labels and the like, complete, accordance with the
Drawings and Specifications Section 540.0300 (Pipes are measured
including fittings and supports)
Sprinkler system
A

25mm diameter

5,053

32mm diameter

893

40mm diameter

554

50mm diameter

607

65mm diameter

405

80mm diameter

422

100mm diameter

591

150mm diameter

1,444

200mm diameter

60

460

Breeching inlet/ Sprinkler quick fill line


K

150mm diameter
Wet riser system

25mm diameter

68

65mm diameter

215

Items as part of Value Engineering (**)


Carried to Collection
A

150mm diameter

733

150mm diameter to stand pipe riser

166

385

External Fire Hydrant Underground Pipe work


Supply and installation of ductile iron pipe works with anti corrosive
protection including fittings, all necessary supports, coupling, markings,
excavation, backfilling, bedding surround, related civil works, fixing and
the like. complete; all in accordance with the Drawings and Specification.
Section 540: 0310
C

200mm diameter
Fire Fighting Pipe Specialties
Supply and installation of fire fighting pipe specialties including all
necessary fixings and accessories, complete; all in accordance with the
Drawings and Specification Section 540.0300

Non return valve


D

50mm diameter

nr

150mm diameter

nr

16

nr

Drain cock valve


F

25mm diameter
Zone control valve assembly

100mm diameter

nr

150mm diameter

11

nr

OS & Y valve
J

50mm diameter

nr

150mm diameter

13

nr

200mm diameter

nr

32

nr

20

nr

Landing valve
M

65mm diameter with 65mm x 40mm reducer caps in stand pipe riser

Items as part of Value Engineering (**)


Carried to Collection
Automatic relief valve (ARV)
A

25mm diameter with pressure gauge


Flexible connectors

50mm diameter

nr

150mm diameter

nr

200mm diameter

nr

nr

Pressure gauges
E

50mm diameter pipe

150mm diameter pipe

nr

200mm diameter pipe

nr

12

nr

nr

1,488

nr

Test drain valve


H

50mm diameter
Solenoids valve

32mm diameter to cold room


Equipment
Supply and installation of the fire fighting components, complete; all in
accordance with the Drawings and Specification Section 540.0300
Sprinkler head

Pendant type

Wall mounted type

134

nr

Wall mounted type external coverage

429

nr

Upright type

875

nr

Recessed dry type to cold rooms

10

nr

114

nr

Fire Extinguishers
Q

Dry powder portable fire extinguishers, 4.5kg


Items as part of Value Engineering (**)
Carried to Collection

CO2 fire extinguishers, 4.5kg

114

nr

Dry chemical portable fire extinguisher class ABC 5.0 kg

39

nr

CO2 portable fire extinguisher 5.0 kg

39

nr

57

nr

Fire Hose Cabinet & Valves


Supply and installation of fire hose cabinet and valves, including all
fittings, fixtures and accessories, complete; all in accordance with the
Drawings and Specification Section 540.0300
D

Fire hose cabinet (including fire hose reels and fire extinguishers )

Fire hose cabinet (including fire hose reels and fire extinguishers ) at
Roof Level

nr

4 way fire brigade breaching inlet, 150mm diameter with NRV

nr

Fire tank quick fill box, 150mm diameter with NRV

nr

External fire hydrant

nr

Temperature relief valve

nr

Main relief valve

nr

Pressure switch

nr

nr

nr

Supply and installation of alarm station, including all in fittings, fixings,


accessories and connections, complete; all in accordance with the
Drawings and Specification Section 540.0300
M

Alarm check valve with 100mm diameter pipe


Pumps and Fittings
Supply and installation of pressure vessels, including fittings and
connections, complete; all in accordance with the Drawings and
Specification Section 540.0300

Pressure vessel to fire pumps

Items as part of Value Engineering (**)


Carried to Collection
Supply and installation of fire fighting pumps including all necessary
control panels, gauges, air vents, , wiring, hangers, supports bases,
vibration isolator and connection to power supply for the proper operation
of the system, labels, marking, testing and commissioning, complete; all
in accordance with the Drawings and Specification.Section 540.1200
A

Diesel driven pump, 1000 US Gallon/min @ 12 bar head

nr

Electrical driven pump, 1000 US Gallon/min @ 12 bar head

nr

Jockey pump, 10 US Gallon/min @ 12 bar head

nr

Fire Suppression Systems


Supply and installation of clean agent gaseous fire suppression system,
including testing and commissioning, complete; all in accordance with the
Drawings and Specification Section 540.1100
D

CBS room - LG- 003 (20.98m2)

item

Telephone intake room - LG -004 (20.56m2)

item

MDF room - LG - 005 ( 20.53m2)

item

Security,BMS room - LG -006 (20.30m2)

item

IT room - LG- 013 (43.40m2)

item

LV room - LG- -09 (143.60m2)

item

Supply and installation of foam deluge fire suppression system, including


testing and commissioning; complete all in accordance with the Drawings
and Specification Section 540.1600
K

Genset room (50.72 m2)

item

Generator bulk tank room (21.11 m2)

item

Supply and installation of pre-action sprinkler system, including testing


and commissioning, complete: all in accordance with the Drawings and
Specification Section 540.1700
M

Lift shaft - 03- 03

item

Lift shaft - 03- 04

item

Items as part of Value Engineering (**)


Carried to Collection
Supply and installation of ANSUL piranha fire suppression system,
including testing and commissioning, complete; all in accordance with the
Drawings and Specification
A

Banquet kitchen area for Main kitchen - LG -

item

Kitchen area for All Day Dining - GF - 0019

item

Sundries
C

Allow for suction, drain and filling in pipe works connected to fire water
storage tank including float valves, float control valve assembly, water
level probe rods, suction foot valves, sensors, internal ladders, alarms,
complete

Items as part of Value Engineering (**)


Carried to Collection

LIGHTNING PROTECTION SYSTEM


Lightning Protection System

item

Supply and installation of lightning protection system, complete; all in


accordance with the Drawings and Specification Section 674.0100
A

25mm x 3mm thick copper tape

2,576

1x1C 70 mm2 Cu./PVC earth cable (**)

1,653

Test Link With 100X100mm Junction Box (rev qty 32 (**)

92

nr

Square copper clamp in 25mmx3mm copper tape

173

nr

Lightning protection pit ref. LP- EP (rev qty 32 (**)

92

nr

Copper down conductor connection

182

nr

Allow for completion of the lightning protection connections to all


mechanical equipment on the roof including earth bars, wires and the like

item

Air Terminal 16 x 500

nr

Air Terminal base

nr

Tape clip

nr

Items as part of Value Engineering (**)


Carried to Collection
Section No.6
SERVICES

Bill No.9
5K: PROTECTIVE INSTALLATIONS
COLLECTION
Page No
Total Brought Forward from Page No.

-327-328-329-330-331-332-333-

Items as part of Value Engineering (**)


Carried Forward to Summary of Section No. 6

5L:COMMUNICATION INSTALLATIONS
Note: The rate should be included testing & commissioning,
identifications, labels, charts, spare parts, tools, loose keys, consumables
stores, documents, drawings, warranties, operation & maintenance
manuals, cuttings, mortices,chases,protective paintings,cleaning and
touch up paints, complete.

FIRE ALARM AND VOICE EVACUATION SERVICES


Cable tray and trunking
Supply and installation of cable trays and trunking including all fittings,
supports, complete; all in accordance with the Drawings and
Specification Section 621:0200 and 621:0300
A

200mm x 35mm HDGI cable tray

23

100mm x 35mm HDGI cable tray

32

150mm x 150mm HDGI cable trunking

356

nr

Control panel
Supply and installation of fire alarm control panel with battery & charger,
rack including fixing, fittings, interlocks, earth & main connections,
complete; all in accordance with the Drawings and Specification Section
691:0100-1500 and 692:0100-300
D

Main fire alarm monitoring panel (MFAMP-LGF) and voice command


center (Analogue addressable), fire alarm control panel workstation with
PC and 21" colour monitor (touch screen), printer and controller
Final sub circuits and auxiliary installations
Supply and installation of final circuits for the following items including
conduits and cables complete; all in accordance with the Drawings and
Specification Section 621:0200-800 and 622:0400

Fire alarm manual call point

92

nr

Fire alarm manual call point W/P

38

nr

Fireman's phone jack

33

nr

Intelligent addressable heat detector with standard base

156

nr

Intelligent addressable multi-sensor detector with standard base

79

nr

nr

Intelligent addressable smoke detector with sounder

400

nr

Intelligent addressable smoke detector with standard base

476

nr

Combined intelligent addressable smoke detector and strobe to


accessible area

10

nr

nr

Intelligent addressable multisensor detector with sounder

Carried to Collection
P

Flame detector

Intelligent addressable smoke detector with standard base in ceiling void

343

nr

Surface mounted horn voice evacuation speaker with strobe [weather


proof] (**)

84

nr

Ceiling recessed voice evacuation speaker (**)

263

nr

Wall mounted voice evacuation speaker (**)

37

nr

Ceiling recessed voice evacuation speaker with strobe (**)

220

nr

Ceiling surface mounted voice evacuation speaker (**)

nr

Ceiling surface mounted voice evacuation speaker and strobe (**)

26

nr

Wall mounted voice evacuation speaker with strobe

nr

Equipment
Supply and installation of the fire alarm equipment including fixtures and
fittings, complete; all in accordance with the Drawings and Specification
Section 691:0100-1500 and 692:0100-300
C

End of line resistor

15

nr

Interface unit

27

nr

Fire alarm manual call point

92

nr

Fire alarm manual call point W/P

38

nr

Fireman's phone jack

33

nr

Intelligent addressable heat detector with standard base

156

nr

Intelligent addressable multi-sensor detector with standard base

79

nr

Intelligent addressable multi-sensor detector with sounder

nr

Intelligent addressable smoke detector with sounder

400

nr

Intelligent addressable smoke detector with standard base

476

nr

Combined intelligent addressable smoke detector and strobe to


accessible area

10

nr

Flame detector

nr

Intelligent addressable smoke detector with standard base in ceiling void

343

nr

Surface mounted horn voice evacuation speaker with strobe [weather


proof] (**)

84

nr

Ceiling recessed voice evacuation speaker (**)

263

nr

Items as part of Value Engineering (**)


Carried to Collection
T

Wall mounted voice evacuation speaker (**)

37

nr

Ceiling recessed voice evacuation speaker with strobe (**)

220

nr

Ceiling surface mounted voice evacuation speaker (**)

nr

Ceiling surface mounted voice evacuation speaker and strobe (**)

26

nr

Wall mounted voice evacuation speaker with strobe (**)

nr

Mimic panel

nr

Sundries
C

Allow interface with HVAC system

item

Allow interface with fire fighting system

item

Allow interface with intelligent lighting control system

item

Allow interface with PA/BGM system

item

Allow interface with elevators

item

Allow interface with central battery emergency lighting system

item

Allow interface with security access control system

item

Allow interface with CCTV system

item

Allow interface with BMS system

item

Carried to Collection

DISABLED AND REFUGE SYSTEM


Final sub circuits and auxiliary installations
Supply and installation of final circuits to disable and refuge equipments,
including conduits and cables complete; all in accordance with the
Drawings and Specification

Pull cord

nr

Tone generator

nr

Reset switch

nr

Disable refuge call point

nr

Fire Alarm Interface

nr

Equipment
Supply and installation of disable and refuge equipment, complete; all in
accordance with the Drawings and Specification
G

Disable alarm and refuge alarm control panel

nr

Pull cord

nr

Tone generator

nr

Reset switch

nr

Disable refuge call point

nr

Fire Alarm Interface

nr

Carried to Collection

CCTV AND SECURITY SYSTEM


Cables
Supply and installation of cables, laid in ducts, cable tray or trunking
(measured elsewhere) including connection to equipment as required,
complete; all in accordance with the Drawings and Specification Section
28 2000
A

8 core OM3/4 primary 10Gbps uplink

2,569

8 core OM3/4 failover 10Gbps uplink

2,569

Cable Tray and Trunking


Supply and installation of cable trays including all fittings, supports,
complete; all in accordance with the Drawings and Specification Section
621:0200

200mm x 35mm GI cable tray for CCTV/SEC/MATV/BMS

411

1,142

Supply and installation of cable trunking including all fittings, supports,


complete; all in accordance with the Drawings and Specification Section
621:0300
F

75mm x 75mm GI cable trunking for CCTV/SEC/MATV/BMS


Final sub circuits and auxiliary installations
Supply and installation of final circuits to CCTV system including conduits
and cables, complete; all in accordance with the Drawings and
Specification Section 28 2000
Carried to Collection

QUANTITY (% OF COMPLETION)
PREVIOUS

CURRENT

CUMULATIVE

0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%

AMOUNT(SAR)
PREVIOUS

CURRENT

CUMULATIVE

15

10
80

757.00

816.00

233.00