Etisalat Wireless Network

Modernization Project Introduction


www.huawei.com

2014-Jan-2

HUAWEI TECHNOLOGIES CO., LTD.

Page 1

BBU Main Processing & Transmission unit


LMPT (LTE Main Processing & Transmission unit)
2FE/GE electrical port, 2FE/GE optical port , Support IPSec

GTMU (GSM Transmission & Timing & Management Unit)


4E1/T1, 1FE electrical port, 1FE optical port

WMPT (WCDMA Main Processing & Transmission unit)

UMPT (Universal Main Processing & Transmission Board)

4E1/T1, 1FE electrical port, 1FE optical port

FAN

0
1
2
3

4
5
6
7

Support IPSec, GUL concurrent modeSRAN8.0


4E1/T1, 1FE/GE electrical port, 1FE/GE optical port

UPEU
UPEU

UMPT

WMPT/LMPT/UMPT inserted in slot 6/7


GTMU inserted in slot 6(both slots 5 and 6 occupied)

HUAWEI TECHNOLOGIES CO., LTD.

FE/GE (Electrical)

CI
FE/GE (Optical)

E1/T1

G/ U/L light indicator

WBBPf4/LBBPd board
Function:
Provides CPRI ports for communication with the RF modules (RRU)
Processes uplink and downlink baseband signals.

WBBPf for 3G

WBBPf inserted in slot 0/1/2/3/4/5


FAN

Interface ports: 6 (CPRI0 ~CPRI5)

0
1
2
3

4
5
6
7

UPEU
UPEU

WBBPf4: 6 cells, DL/UL: 768CE/512CE

LBBPd for LTE


LBBPd inserted in slot 0/1/2/3/4/5
FAN

Interface ports: 6 (CPRI0 ~CPRI5)


HUAWEI TECHNOLOGIES CO., LTD.

0
1
2
3

4
5
6
7

UPEU
UPEU

LBBPd3: 6x20M, 2T2R, DL/UL: 600M/300Mbps

UCIU/UBRIb board

UCIU: universal inter-connection infrastructure unit


S0

GCK

UCIU inserted in slot 4


FAN

M0 ~ M4

4
5
6
7

0
1
2
3

UPEU
UPEU

UBRIb for 2G
Provides CPRI ports for communication with the RF modules (RRU)

UBRIb inserted in slot 03

FAN

0
1
2
3

4
5
6
7

UPEU
UPEU

BBU3900

HUAWEI TECHNOLOGIES CO., LTD.

WMPT /LMPT/GTMUb evolved.

UPEU

F
A
N

UPEU
LBBP

LMPT

UPEU
F
A
N

UMPT(GUL)
LBBP

LMPT
evolved

UPEU

LMPT evolved: supports SingleOM and provides LTE signaling processing function.

HUAWEI TECHNOLOGIES CO., LTD.

BBU3900 Slot Assignment solution reusing the existing BBU

UBRIb+2G900

UBRIb+2G900

UBRIb+2G1800

UBRIb+2G1800

WBBPf+3G900

WBBPf+3G900

LBBP+4G1800

UMPT
(Existing L)

Reusing the existing 4G BBU ,existing


UMPT board, New
2G900&2G1800+3G900

HUAWEI TECHNOLOGIES CO., LTD.

LBBP+4G1800

UMPT
LMPT
(Existing L)

Reusing the existing 4G BBU ,existing


LMPT board, New
2G900&2G1800+3G900

Page 6

Existing

New

New

BBU3900 Slot Assignment solution New BBU


UBRIb+2G900

UBRIb+2G900

UBRIb+2G1800

UBRIb+2G1800

WBBf+3G900

UMPT
G+U)

UMPT G)

New 2G900&2G1800+3G900 with new BBU


New 2G900+2G1800 with new BBU

HUAWEI TECHNOLOGIES CO., LTD.

Page 7

BBU3900 Working in Multi-Mode with a Co-MPT

Typical board configurations for a BBU3900 with a UMPT_GU board

HUAWEI TECHNOLOGIES CO., LTD.

Page 8

New MiniShelter equipment layout


cable tray(1U)

spare Space(6U)

DCDU12B-3(0U)
DCDU12B-2(1U)
BBU2(2U)
spare Space(1U)
DCDU12B-1(1U)
BBU1(2U)
spare Space(2U)

Rectifier ETP48200(6U)

Battery1

Battery2

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

HUAWEI TECHNOLOGIES CO., LTD.

(2.1M+AH1500&PC500D+Rack)
Item

Basic unit
specifications

Equipment Compartment
Internal dimensions: 800 mm
x 800 mm x 1800 mm (31.50
in. x 31.50 in. x 70.87 in.)
Maximum external
dimensions: 905 mm x 1135
mm x 2110 mm (35.63 in. x
44.68 in. x 83.07 in.,

Typical
temperature
control mode

AH1500 (maximum power


consumption AC/ DC 640
W/200 W)
PC500D (maximum power
consumption DC 200 W)

Integration

Power system, baseband unit


(BBU), environment
monitoring unit, alternating
current distribution box
(ACDB), and automatic
transfer switch (ATS), and so
on

IP protection
level

IP55

Weight

240 kg (529.20 lb)

Page 9

New MiniShelter installation information


Install as
single
cabinet

HUAWEI TECHNOLOGIES CO., LTD.

Cabinet bottom
base view

Page 10

New minishelter Rectifier-ETP48200


Power Specifications

Rectifier module
(PSU)

HUAWEI TECHNOLOGIES CO., LTD.

Page 11

New minishelter AC power cable connection


Single phase case

HUAWEI TECHNOLOGIES CO., LTD.

Page 12

New minishelter Battery cable connection


One string battery= 4 pcs
sell.
Battery capacity:100AH.
Weight: 124KG/string

HUAWEI TECHNOLOGIES CO., LTD.

Page 13

New minishelter Power monitoring unit

Signal resource

Minishelter
alarm list:

Alarm name
Mains failures
DC low voltage
Rectifier failures
SPD failure
Load Breaker burn-out
High temperature
Door open
Air-conditioner failures

HUAWEI TECHNOLOGIES CO., LTD.

Alarm type Power port


NO
NO
NO
NO
NO
NO
NO
NO

ALM1
ALM2
ALM3
ALM4
ALM5
ALM6
ALM7
ALM8

BBU port
UPEU
EXT-ALM1

UPEU
EXT-ALM0

Page 14

Cable color
White/orange+, Orangewhite/green+, Bluewhite/blue+, Green
white/brown ,BrownWhite/orange+, Orangewhite/green+, Bluewhite/blue+, Green
white/brown ,Brown-

New minishelter Power alarm cable connection

HUAWEI TECHNOLOGIES CO., LTD.

Page 15

New minishelter sensor cable connection

Door sensor

Battery Temperature
sensor

Temperature &
humidity sensor
sensor

HUAWEI TECHNOLOGIES CO., LTD.

Page 16

New minishelter Grounding cable connection


EMUA (1U)

Door
Space (15U)

Rack
Rack Ground Point
Indoor ground busbar

DCDU

Grounding cable
layout

SLPU1U

BBU

Power
Power
System
ETP48200
(8U)
DCDU (1U)

BBU (2U)
SLPU (1U)

Ground
HUAWEI TECHNOLOGIES CO., LTD.

12V
150Ah

12V
150Ah

12V
150Ah

12V
150Ah

12V
150Ah

12V
150Ah

12V
150Ah

12V
150Ah

Outdoor ground busbar

New TP4860C
2

System Specifications

Dimensions (H x W
x D)

630 mm x 450 mm x 300 mm (The width of the protruding part of the door [60 mm]
is extracted from the cabinet depth.)

Weight

29 kg (excluding the weights of PSUs and storage batteries)

Rated capacity

The maximum current is 60 A, in which case three 30 A PSUs are installed. 15 A


PSUs are also supported.

Installation

Mounted on a wall, floor, or pole.

Cable routing

Cables are routed out from the bottom.

Maintenance

Maintained from the front, supporting module replacement.

Protection level

IP55

Noise

The operation noise is lower than 55 dB, complying with YD/T 1058

Heat dissipation

Natural-ventilation unit

Battery (optional)

Built in with a 48 V 20 Ah/40 Ah battery string.

Electrical Specifications

Internal Components
1
2
3
4
5

PSU
PMU
Fan
Power distribution unit (PDU)

6
7
8
9

Door monitor

10

Battery Space
Baffle plate
Air Filter

HUAWEI TECHNOLOGIES CO., LTD.

AC input system

Single-phase (L-N or L1-L2. The live wire and neutral wire can be reversely
connected.)

Input voltage

85=300VAC (The rated input voltage is 220 V AC.)

Input frequency

4565 Hz (The default input frequency is 50 Hz or 60 Hz.)

Output voltage

43.258 V DC (The default output voltage is 53.5 V DC.)

AC surge protection
level

Level C (20/40 kA, 8/20 s). Level B (30/60 kA, 8/20 s) can be customized.

DC surge protection

Differential mode: 10 kA
Common mode: 20 kA

Surge protection for


signal ports

Differential mode: 3 kA
Common mode: 5 kA

New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.

New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.

New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.

New TP4860C installation information

Item
Rated capacity
Rated voltage
Operating temperature
Dimensions (H x W x D)
Weight
Maximum discharge power
Maximum charge current

HUAWEI TECHNOLOGIES CO., LTD.

Specifications
40 Ah
48 V DC
20C to +55C
133 mm x 385 mm x 350
mm
27 kg
1500 W (the backup time is
1 hour)
8A

New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.

Item

TP4860C-D06A1

AC input circuit
breaker
Maintenance socket
AC surge protection
device (SPD)
DC SPD
DC output circuit
breaker
Battery circuit
breaker

One 2-pole 32 A
circuit breaker
1
Class C, 4-pole
1
Three 1-pole 32A
circuit breakers
One 1-pole 63 A
circuit breaker

DCDU12B View

HUAWEI TECHNOLOGIES CO., LTD.

Page 24

APM30 DC(TMC11H ,Ver.D)


Power Specifications

Exterior of the APM30H(TMC11H)

Supplied with -48 V DC power.


Configured with a DCDU-12B, which distributes power into RRUs and the
BBU, fan assembly, and transmission equipment in the TMC11H
.Parameter
Specifications
Characteris Input voltage range
tics of DC Typical input voltage
input
Maximum input current

Input mode
Characteris DC distribution
tics of DC
output
Typical output voltage
Protection

HUAWEI TECHNOLOGIES CO., LTD.

-38.4 V DC to -57 V DC
-48 V DC
The maximum input current depends on the application
scenario. In a distributed base station: 160 A
In a separated macro base station: 30 A (When the TMC11H is
configured together with the APM30H, the APM30H supplies
power to the TMC11H.)
-48 V DC power input, supporting the one-hole M6 OT terminal
Ten -48 V DC outputs: LOAD0 to LOAD9, used to supply power
to the customer equipment
-48 V DC
Providing overcurrent protection and short-circuit protection for
the DC power

Page 25

APM30H DC (TMC11H ,Ver.D)


Exterior of the APM30H
Parameter

Specifications

Remarks

Dimensions (H x
W x D)

Cabinet (without the


The TMC11H and APM30H have the same
base): 700 mm x 600 mm exterior and base.
x 480 mm (27.56 in. x
23.62 in. x 18.90 in.)
Base: 200 mm x 600 mm
x 434 mm (7.87 in. x
23.62 in. x 17.09 in.)
Space for the
11 U x 19 in. x 380 mm The depth includes 100 mm (3.94 in.) in front of
customer
the columns and 280 mm (11.02 in.) between the
equipment (H x W
columns and the rear of the cabinet.
x D)
Cabinet weight
47 kg (103.64 lb)
Total weight of the equipment
Including the cabinet frame, outer air
circulation assembly (heat dissipation core and
outer air circulation fan), inner air circulation
fan assembly, DCDU, and cables
Excluding the customer transmission
equipment
Method of
It can be installed on the In stack mode, the TMC11H must be installed on
installation
ground, pole, or wall. It the top of the RFC, IBBS200D, or IBBS200T
can also be installed on
an RFC, IBBS200D, or
IBBS200T in stack mode.

HUAWEI TECHNOLOGIES CO., LTD.

Page 26

APM30 H( TMC11H VerD detail component)


No. Component
Remarks
1
Outer air
circulation
The assembly is installed on the front door of the cabinet, dissipating heat from the cabinet.
assembly
2
The junction box converts one AC input to four AC outputs and is used in the scenario where a service outlet unit (SOU) and
Junction box
multiple heating films or heaters are configured.
3
FAN 02D
The fan assembly is configured with fans and central monitoring unit type EA (CMUEA), dissipating heat from the cabinet.
4
To provide protection for trunk signals,
SLPU
To provide protection for monitoring signals.
5
Door sensor The door status sensor monitors the status (open or closed) of the cabinet door.
6
ELU
The electronic label unit (ELU) reports the cabinet type automatically to facilitate troubleshooting.
7
The direct current distribution unit-12B (DCDU-12B) or direct current distribution unit-12C (DCDU-12C) in the TMC11H
DCDU-12B or
distributes DC power to all the components in the TMC11H. A DCDU-12B or DCDU-12C is 1 U high. The DCDU varies with the
DCDU-12C
installation scenarios.
8
BBU3900
A maximum of two BBU3900s can be configured in a TMC11H.
9
EMUA
The environment monitoring unit type A (EMUA) monitors environment of the equipment.
10
A filler module is a plastic component with a height of 1 U in the cabinet, preventing the heat reflux in the empty space below the
Filler module
BBU.
11
The AC heater ensures that components in the cabinet work within the acceptable temperature range when the surrounding
AC heater
temperature is low. It can be preferentially installed in the 1 U space at the bottom of the cabinet.

HUAWEI TECHNOLOGIES CO., LTD.

Page 27

APM30 AC (Ver.D)
Power Specifications

Exterior of the APM30H AC

Item

Specifications
200 V AC to 240 V AC (220 V AC single-phase)
200/346 V AC to 240/415 V AC (220/380 V AC three-phase)
Typical input voltage

100/200 V AC to 120/240 V AC (110 V AC dual-live-wire)


Characteristics of AC input
120/208 V AC to 127/220 V AC (120 V AC dual-live-wire)

Rated input current

Output voltage range


Output current range
Typical output voltage

53 A (220 V AC single-phase)
23 A (220/380 V AC three-phase)
55 A (110 V AC dual-live-wire)
52 A (120 V AC dual-live-wire)
-43.2 V DC to -57 V DC
0 A to 150 A
-53.5 V DC
The number of DC outputs depends on the application scenario.

Characteristics of DC output

DC outputs

A distributed base station uses 17 DC outputs


A separated base station uses 12 DC outputs.

DC output power

HUAWEI TECHNOLOGIES CO., LTD.

9000 W (When there is no backup PSU, the maximum power of each PSU is
3000 W.)

Page 28

APM30H AC (Ver.D)
Item

Exterior of the APM30H

Specification

68 kg
Weight

87 kg

Cabinet dimensions (H x W x D)

700 mm x 600 mm x 480 mm The base is not included.

Base dimensions (H x W x D)

200 mm x 600 mm x 434 mm -

Customer equipment dimensions (H


7 U x 19 in. x 380 mm
x W x D)

The depth consists of the rear (280 mm)


and front (100 mm) of the installation
plane for subrack mounting ears.

Space for cabling and maintenance


70 mm
in front of the cabinet

Installation option

HUAWEI TECHNOLOGIES CO., LTD.

Remarks

Total weight of the equipment


Including the cabinet frame, inner air
circulation fan box, outer air circulation
fan box, core of the heat exchanger,
embedded power subrack unit (EPU),
and cables
Excluding the baseband processing unit
(BBU), customer equipment, power
monitoring unit (PMU), and PSUs
Weight of the cabinet in full configuration
Including the cabinet, one PMU, three
PSUs, and one BBU
Excluding customer equipment

The APM30H can be installed


on a floor, wall, or pole. It can
also be stacked with the radio The APM30H must
frequency cabinet (RFC),
IBBS200D, or IBBS200T.

Page 29

APM30H AC-APM30H+Battery(Used for a Distributed Base Station)


Figure 1 Scenario where the APM30H is stacked with a battery cabinet and is used for a distributed base station

When the APM30H is used for a distributed


base station:
The APM30H provides 7 U-high space for
installing the BBU and transmission
equipment. The embedded power supply
system provides -48 V DC power to the
distributed base station and transmission
equipment and charges battery groups in a
battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the distributed base station and
transmission equipment

HUAWEI TECHNOLOGIES CO., LTD.

Page 30

APM30H AC-BTS3900A(Used for an Outdoor Macro Base Station)


Figure 2 Scenario where the APM30H is used for an outdoor macro base station

When the APM30H is used for an outdoor


macro base station:
The APM30H provides 7 U-high space for
installing the baseband processing unit (BBU)
and transmission equipment. The embedded
power supply system provides -48 V DC power
to the BBU, radio frequency unit (RFU), and
transmission equipment and charges battery
groups in a battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the BBU, RFU, and transmission
equipment.
The APM30H provides alarm reporting functions
for radio frequency cabinet (RFC) fans, door
status sensor, direct current distribution unit
(DCDU), and battery cabinet.

HUAWEI TECHNOLOGIES CO., LTD.

Page 31

OMB (Ver.C)
The OMB (Ver.C) is designed for SRAN8.0 and later versions
Base stations supported by the OMB (Ver.C):
DBS3900

The OMB (Ver.C) supports all current RRU versions.

DBS3900 (AC)

DBS3900 (DC)
Page 32

HUAWEI TECHNOLOGIES CO., LTD.

OMB (Ver.CMPE Specifications ) in AC Scenarios


Dimensions (H x W x D)

600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)

Temperature Range

-33oC to 50oC (-27.4oF to 131oF)

Weight

30 kg or 66.15 lb (without a BBU)

Protection Class

IP55

Admission Requirement

CE

Power Supply Mode

110 V AC dual-live-wire or 220 V AC single-phase

Temperature Control Subsystem

Heat exchanger

Power Supply Subsystem


ETP48100-A1

Embedded power system, with a maximum power capacity of 100 A

Power Distribution Subsystem

Ten power outputs of 30 A

Output DC power distribution: two 100 A outputs

AC power port: rated 20 kA; maximum 40 kA; 8/20 us waveform

Surge Protection

DC power output port: 10 kA in differential mode and 20 kA in


common mode; 8/20 us waveform

Cable Outlet Position

Bottom of the cabinet

Page 33

HUAWEI TECHNOLOGIES CO., LTD.

Structure and Components of the OMB in AC


Scenarios
1
2
3
4
5
6
7
8

10

No.

Configuration

Description

Mandatory

Electronic label unit (ELU)

Mandatory

FAU01D-01 (inner air circulation fan


assembly)

Mandatory

Door status sensor

Mandatory

SPD40/S (AC surge protector)

Mandatory

HEUB (control unit for heat


exchanging)

Mandatory

PMU11A (power management unit)

Mandatory

PSU (R4850G2 rectifier)

Mandatory

PDU10D-01 (DC power distribution


unit)

Mandatory

ETP48100-A1 (embedded power


system)

10

Mandatory

FAU01D-01 (outer air circulation


fan assembly)

Page 34

HUAWEI TECHNOLOGIES CO., LTD.

OMB (Ver.C) MPE Specifications in DC Scenarios


Dimensions (H x W x D)

600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)

Temperature Range

-33oC to 50oC (-27.4oF to 131oF)

Weight

21 kg or 46.31 lb (without a BBU)

Protection Class

IP55

Admission Certification

CE

Power Supply Mode

-48 V DC

Temperature Control

Subsystem

Heat exchanger

Power Distribution
Subsystem

Ten power outputs of 30 A

Surge Protection

DC power output port: 10 kA in differential mode and 20 kA in common mode;


8/20 us waveform

Cable Outlet Position

Bottom of the cabinet

Page 35

HUAWEI TECHNOLOGIES CO., LTD.

Structure and Components of the OMB in DC


Scenarios
1
2
3
4
5
6

No.

Configuration

Description

Mandatory

ELU

Mandatory

FAU01D-01 (inner air circulation fan


assembly)

Mandatory

Door status sensor

Mandatory

HEUB (control unit for heat


exchanging)

1 U space for customer equipment

Mandatory

PDU10D-01 (DC power distribution


unit)

Mandatory

FAU01D-01 (outer air circulation fan


assembly)

Page 36

HUAWEI TECHNOLOGIES CO., LTD.

Engineering Interface of the OMB (Ver.C)

Engineering Interface of the OMB (Ver.C) in AC Scenarios


AC Input Mode

Number of PSUs

Requirements
Breakers

for

AC

Circuit

Input Power Cable

220 V AC single-phase

32 A, 1 P

4 mm2

110 V AC dual-live-wire

32 A, 2 P

4 mm2

220 V AC single-phase

20A, 1 P

4 mm2

110 V AC dual-live-wire

20 A, 2 P

4 mm2

Remarks
The circuit breaker is connected to the L phase.

The circuit breaker is connected to the L phase.

Engineering Interface of the OMB (Ver.C) in DC Scenarios


Related Unit
Configuration

RRU Power

Number of
RRUs

BBU: 450

300 W

1~3

50A, 1 P

16 mm2

5m

300 W

4~6

80 A, 1 P

16 mm2

5m

RRUs of
the same
model

400 W

1~3

63 A, 1 P

16 mm2

5m

400 W

4~6

100 A, 1 P

16 mm2

5m

mm2

5m

Input Power
Cable

Distance Between the OMB (Ver.C)


and External Power Equipment

560 W

1~3

80 A, 1 P

16

560 W

4~6

125 A, 1 P

25 mm2

5m

2x60 A, 2 P

2x16 mm2

5m

80 A, 1 P

16 mm2

5m

300 W

300 W

RRUs of
different
models

400 W

BBU: 450

Requirements for
DC Circuit Breakers

300 W

400W

1.

core cables, each with dual insulation


layers.
2.

Therefore, ensure that the circuit


breakers and power cables meet the
requirements before the PSUs are
100 A, 1 P

16

mm2

5m

100 A, 1 P

16 mm2

5m

added.

Page 37

HUAWEI TECHNOLOGIES CO., LTD.

If more PSUs are added, the customer


engineering interface must be changed.

560 W
400 W

The AC input power cables are single-

Application Scenarios of the OMB (Ver.C)


Rooftop Outdoor-S2

Greenfield Outdoor-

Urban Street-S5

Indoor-S6

Rural Road-S7

S4

Installing on

Installing on

Installing on

the pole of

the bottom of

the Lamp pole

rooftop

the tower

of the street

Installing on
the wall of

side

Installing on

Installing on

the carport

the pole of

Installing on

the road side

the wall of
veranda

rooftop

Page 38

HUAWEI TECHNOLOGIES CO., LTD.

Stacking the OMB (Ver.C) onto the Top of the BTS3900A


Item

Quantity

Description

Adapting piece I

Secured to the lifting eyes on the


top of the BTS3900A

Adapting piece IV

Used to secure adapting piece I to


the rear of the OMB

The solution of stacking the OMB (Ver.C) onto the BTS3900A is


carried out only as a non-standard solution.

Adapting piece I

Adapting piece IV

Page 39

HUAWEI TECHNOLOGIES CO., LTD.

The changes from OMB Ver.A to OMB Ver.C


AC SPD

SPD40/S

OMB Ver.A

OMB Ver.C
New ELU
unit
New PDU

EPS30-4815AF
HUAWEI TECHNOLOGIES CO., LTD.

ETP48100-A1
Page 40

DBS3900 (-48 V): Outdoor BBU and Outdoor RRUs (Ver.C)


Solution: OMB(-48 V) + 6 x RRU (optional)
DC power cable

A DC OMB Ver.C supports a maximum of six 2x60 W RRUs.

ground cable

The heat consumption of a DC OMB Ver.C cabinet (the total heat consumption of the built-in

feeder

BBC and TC) is lower than or equal to 450 W (with the urban-level noise and in ambient

Optical fiber

temperature of 50C.)
The DC OMB Ver.C supports -48 V power input.
The protection level of the DC OMB Ver.C is IP55.
RR
U
OMB V.C

Power interface
ACDB

The DC input/output port surge protection specification is 10KA/20KA.


The DC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both
on the top of and beside a BTS3900A. In this case, an attachment plate is required and no
footprint is required.
The DC OMB Ver.C can operate in a temperature range of -33C to +50C.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless
Base Stations.

Customer side

Page 41

HUAWEI TECHNOLOGIES CO., LTD.

Back

DBS3900 (AC): Outdoor BBU and Outdoor RRUs (Ver.C)


Solution: OMB (AC) + 6 x RRU (optional)
An AC OMB Ver.C supports a maximum of six 2x60 W RRUs (power backup is not supported when the
load power exceeds 3000 W).

AC power cable
ground cable
feeder
DC power cable
optical fiber

An AC OMB Ver.C has a built-in ETP48100 power supply system and two PSUs, with a maximum output
power of 6000 W (3000 W for a single PSU.)
The AC OMB Ver.C supports 220 V single-phase and 110 V dual-live-wire AC input.
The heat consumption of an AC OMB Ver.C cabinet is lower than or equal to 450 W (the heat consumption

of the BBU is lower than or equal to 250 W) with the urban-level noise and in ambient temperature of
RRU

50C.
The protection level of the AC OMB Ver.C is IP55.

OMB V.C
Power interface
ACDB

The AC OMB Ver.C cannot be installed on a tower and can not be installed at a position higher than 10 m.
The AC OMB Ver.C supports remote RRU.
The AC OMB Ver.C supports a surge protection of a maximum of 40 KA at the AC power input port and 10
KA/20 KA at the DC power output port.
The AC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both on the top of
and beside a BTS3900A. In this case, an attachment plate is required and no footprint is required.

Customer side

The DC OMB Ver.C can operate in a temperature ranging from of -33C and +50C.
Power backup is not supported.

For the power supply requirements, see the Power Supply Interface Requirements for Wireless Base
Stations.

Page 42

HUAWEI TECHNOLOGIES CO., LTD.

Back

DBS Senario

Existing
transmission
equipment
CPRI optical

HUAWEI TECHNOLOGIES CO., LTD.

Page 43

DBS Structure

HUAWEI TECHNOLOGIES CO., LTD.

Page 44

CPRI Cable

Branch of Cable

Appearance of Figure

HUAWEI TECHNOLOGIES CO., LTD.

Connected to Equipment

Page 45

CPRI Cable
Single mode/Multi-mode

Length of branch

Connect to

Connector

CPRI

BBU-RRU

DLC/PC-DLC/PC

Cores
2

CPRI

BBU-RRU

DLC/PC-DLC/PC

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

30m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

40m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

Multi-mode

50m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

Multi-mode

60m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

Multi-mode

80m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

Multi-mode

100m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

Multi-mode

120m

0.03m/0.34m

CPRI

BBU-RRU

DLC/PC-DLC/PC

Multi-mode

150m

0.03m/0.34m

BBU-RRU

DLC/PC-DLC/PC

Single mode

5m

0.34m/0.8m

CPRI
CPRI/Iub

BBU-ODF

DLC/UPC-2FC/UPC

0.34m/0.8m

CPRI/Iub

BBU-ODF

DLC/UPC-2FC/UPC

0.34m/0.8m

CPRI/Iub

BBU-ODF

DLC/UPC-2FC/UPC

BBU-ODF

DLC/UPC-2SC/UPC

Multi-mode

Length
5m

0.03m/0.34m

Multi-mode

10m

0.03m/0.34m

Multi-mode

20m

Multi-mode
Multi-mode

Single mode
Single mode

10m
20m

Be used

Single mode

10m

0.34m/0.8m

CPRI/Iub

Single mode

20m

0.34m/0.8m

CPRI/Iub

BBU-ODF

DLC/UPC-2SC/UPC

Single mode

10m

0.34m/0.8m

CPRI/Iub

BBU-ODF

DLC/UPC-2LC/UPC

Single mode

20m

0.34m/0.8m

CPRI/Iub

BBU-ODF

DLC/UPC-2LC/UPC

Single mode

5m

0.03m/0.8m

CPRI

RRU-ODF

DLC/UPC-2FC/UPC

Single mode

10m

0.03m/0.8m

CPRI

RRU-ODF

DLC/UPC-2FC/UPC

Single mode

20m

0.03m/0.8m

CPRI

RRU-ODF

DLC/UPC-2FC/UPC

Single mode

30m

0.03m/0.8m

CPRI

RRU-ODF

DLC/UPC-2FC/UPC

Single mode

50m

0.03m/0.8m

CPRI

RRU-ODF

DLC/UPC-2FC/UPC

Single mode

10m

0.03m/0.8m

CPRI

RRU-ODF

DLC/UPC-2SC/UPC

Single mode
Single mode
Multi-mode

10m
10m
10m

0.03m/0.8m
0.03m/0.03m
0.03m/0.03m

CPRI
CPRI
CPRI

RRU-ODF
RRU-RRU
RRU-RRU

DLC/UPC-2LC/UPC
DLC/UPC-DLC/UPC
DLC/UPC-DLC/UPC

HUAWEI TECHNOLOGIES CO., LTD.

Page 46

2
2

Existing Transmission SmartAXOT928G-D

HUAWEI TECHNOLOGIES CO., LTD.

Page 47

RRU3936
RRU dimensions

Ports on the RRU panels

RTN(+) / NEG(-) -- Power supply socket


CPRI0/1-- Optical/electrical port 0, connected to the BBU
(2) ANT_TX/RXA TX/RX port A-- supporting RET signal transmission
ANT_RXB RX-- port B
HUAWEI TECHNOLOGIES CO., LTD.

Page 48

RRU installation on pole

One RRUs installed on a pole

Two RRUs installed on a pole

HUAWEI TECHNOLOGIES CO., LTD.

Three RRUs installed on a pole

If on ground

RRU installation on wall

RRU installed on the wall

HUAWEI TECHNOLOGIES CO., LTD.

RRU installation inside shelter

Installing RRUs on the lower level-1


Indoor IFS06

HUAWEI TECHNOLOGIES CO., LTD.

Installing RRUs on the lower level-2


Indoor IFS06

RRU 3936 DC

RRU3936 Multi-mode 900MHz EGSM RRU3826

Port

Connector

Quantity

Function

Item

Specifications

RF port

DIN

Connects to an antenna

Common public
radio interface
(CPRI) port

DLC

Connects to the baseband unit


(BBU3900)

Dimensions (H x
W x D)

400 mm x 240 mm x 160 mm (with the


housing)

Power supply socket

Easy power
receptacle (pressfit
type)

DB9

RET port

400 mm x 220 mm x 140 mm (without


the housing)

Receives 48 V DC power
Weight

15 kg (with the housing)

Connects to a remote control


unit (RCU)

Item

Specifications

Input power

48 V DC; voltage range: 36 V DC to 57 V DC

13.5 kg (without the housing)

The RRU3936 supports AC applications after being configured with an AC/DC power module. For details, see the AC/DC Power
Module User Guide.

HUAWEI TECHNOLOGIES CO., LTD.

Page 52

Jumper Connector Type


Types of connectors for jumpers

HUAWEI TECHNOLOGIES CO., LTD.

Page 53

Jumper Connector Type


Difference between the male connector and female connector

HUAWEI TECHNOLOGIES CO., LTD.

Page 54

Jumper Connector Type


Difference between the DIN connector and N connector

HUAWEI TECHNOLOGIES CO., LTD.

Page 55

Optical Connector and Flange


SC optical connector and flange

HUAWEI TECHNOLOGIES CO., LTD.

Page 56

Optical Connector and Flange


LC optical connector and flange

FC optical connector and flange