You are on page 1of 2

Thermo Scientific Electronics

Ramsey Micro-Tech 2001 and 2101 Integrators


And Micro-Tech 2105 Feeder Controller
Enclosure

Power Requirements

Expansion Slots

Field mount NEMA-4X fiberglass

110/120/220/240 VAC, 50/60 Hz, 66 VA


maximum power.

Model 2001 two slots.


Model 2101 and 2105 five slots.

Environmental

Communications

Operating temperature range -10C to


+50C
Storage -40C to +70C
Humidity up to 95% R.H. noncondensing.

Provides either (selectable) RS-232C,


RS-485 point to point, RS-485 multi-drop
or 20 mA serial loop (passive only). Also
includes clock/calendar and modem
control.
Modbus, Allen Bradley DF1 or Siemens
3964 protocols.
Fieldbus capabilities: Alley Bradley
Remote I/O (blue hose), Siemens
Profibus-DP.

enclosure 15.0 H x 13.25W x 7.39D


(optional mild steel and stainless steel
enclosures available).
Panel mount (MT2101 and MT2105 only)
288 mm x 96 mm DIN 43700. Field wiring
connections on rear with terminal strip that
unplugs with wires intact.

Approvals
All Micro-Tech 2000 electronics are CE
approved. Micro-Tech 2101 and 2105 are
UL approved standard in the panel mount
version and as an option in the field mount
version. UL approval is not available on the
Micro-Tech 2001.

Technology

32-Bit 16 MHz microprocessor with nonvolatile EPROM memory, calibration data


entered by the keyboard is stored in
battery backed CMOS RAM, 10 year
(typical) life.

Instrument Panel

4 line by 20 character alphanumeric


display, vacuum fluorescent, 5 mm
character height, 5 x 7 dot matrix.
Alphanumeric keyboard to enter letters
and numerals. Tactile keys provide positive Shipping Weight
feedback.
Panel mount 18 lbs.
Softkeys to select display functions above Field mount 32 lbs.
keys.
Five LED status indicators.

Panel Mount Micro-Tech Electronics


(Micro-Tech 2001 not available in panel mount version)

Field Mount Micro-Tech Electronics


Revision January 2009

Thermo Scientific Electronics


Ramsey Micro-Tech 2001 and 2101 Integrators
And Micro-Tech 2105 Feeder Controller
Micro-Tech 2001

Micro-Tech 2101

Micro-Tech 2105

Analog Inputs/Outputs

Analog Intpus/Outputs

Analog Intpus/Outputs

Up to four 350 ohm load cells with a


sensitivity of 0.5 to 3.5 mV/V.
R-Cal precision resistor for electronic
calibration.
I/O Board Type A (optional): Provides
one (1) isolated 0-20 or 4-20 mA current
output.
I/O Board Type B (optional): Provides
two (2) differential voltage inputs -5 to +5
VDC. For alternate 0-20 mA or 4-20 mA
inputs (2 each) a scaling resistor is
required. Also provides two (2) isolated
0-20 or 4-20 mA current outputs.

Up to six 350 ohm load cells with


sensitivity of 0.5 to 3.5 mV/V.
R-Cal precision resistor for electronic
calibration.
I/O Board Type A (optional): Provides
one (1) isolated 0-20 or 4-20 mA current
output.
I/O Board Type B (optional): Provides
two (2) differential voltage inputs -5 to +5
VDC. For alternate 0-20 mA or 4-20 mA
inputs (2 each) a scaling resistor is
required. Also provides two (2) isolated
0-20 or 4-20 mA current outputs.

Up to six 350 ohm load cells with


sensitivity of 0.5 to 3.5 mV/V.
R-Cal precision resistor for electronic
calibration.
I/O Board Type A (optional): Provides
one (1) isolated 0-20 or 4-20 mA current
output.
I/O Board Type B (optional): Provides
two (2) differential voltage inputs -5 to +5
VDC. For alternate 0-20 mA or 4-20 mA
inputs (2 each) a scaling resistor is
required. Also provides two (2) isolated
0-20 or 4-20 mA current outputs.

Digital Inputs/Outputs

Digital Inputs/Outputs

Digital Inputs/Outputs

Inputs:
Single belt speed input from speed
sensor.
Two (2) general purpose user defined
inputs (OPTO 22s optional).
Outputs:
One (1) alarm contact optically isolated
OPTO 22 for microprocessor failure.
Three (3) general purpose user defined
outputs. 1-OPTO 22 standard (additional
OPTO 22s optional).
Optional Digital I/O board provides either
4 in/16 out or 16 in/4 out optically isolated.

Inputs:
Two (2) belt speed inputs for redundant
speed sensors or belt slip detection.
Two (2) general purpose user defined
inputs (OPTO 22s optional).
Outputs:
One (1) alarm contact optically isolated
OPTO 22 for microprocessor failure.
Three (3) general purpose user defined
outputs. 1-OPTO 22 standard (additional
OPTO 22s optional).
Optional Digital I/O board provides either
4 in/16 out or 16 in/4 out optically isolated.

Inputs:
Belt speed input from speed sensor.
Three (3) opto-isolated contact inputs
(standard) (Feeder running, start-stop,
interrupt, plugged chute, etc.).
Outputs:
One (1) alarm contact optically isolated
OPTO 22 for microprocessor failure.
Three (3) general purpose user defined
outputs. 1-OPTO 22 standard (additional
OPTO 22s optional).
Optional Digital I/O board provides either
4 in/16 out or 16 in/4 out optically isolated.

A Part of Thermo Fisher Scientific

Please contact our office for additional information:


Thermo Fisher Scientific
501 90th Avenue NW
Minneapolis, MN 55433
Ph: +1 (800) 445-3503
Ph: +1 (763) 783-2500
Fx: +1 (763) 783-2525
www.thermo.com/bulk-handling
Revision January 2009

You might also like