You are on page 1of 4

SiXTM Series

SiXFOB

This bi-directional wireless key fob (wireless key) is


intended for use with Honeywell controls that support
SiX series devices.
Press and hold each button about 2 seconds to
activate. (For two-button Panic, press and hold both
buttons for 2 seconds.)

Installation Instructions

Button Keys 1-4

1
(Loop 3)

2
(Loop 2)

(Corresponding Loop numbers are


seen when programming the key
fob through the Zone Programming
menu.)
*SIA NOTE: SIA requires 2-button press for
panic functions. Select 8 Button (or 6
Button) Key Type and follow the directions
in the For SIA Installations section below.

Enroll and Program the SiXFOB


1. Set the Lyric Controller in Programming mode. Go to the
Keys enrollment screen, select Add New, select Key Fob*
Key Type and select Serial Number. (*Refer to For SIA
Installations section below for SIA selections.)
2. Press and hold the top two buttons for about two seconds to
activate the enrollment process.
3. The LEDs alternately flash green during enrollment (up to
about 20 seconds).

NOTE: If enrollment is not confirmed, press and hold the top two
buttons for two seconds again to restart the enrollment process.

6. Use Zone Program menu to change default key functions as


desired.
7. Assign a User Number to the key fob and press SAVE.
Follow instructions in the Controllers programming guide to
program the SiXFOB services.
The device can also be manually enrolled. See the Controllers
Programming Guide for details.

8*
(Loop 5)

4
(Loop 1)

Programming Mode > Keys > Add New >


Select Key Type [Key Fob*] > Serial Number

Serial Number

Loop Number

Zone Description 1

Zone Description 2

Device Type

Response Type

Alarm Report

Chime

2
~ 2 seconds

Supervision

Panic

Home

3
0

NOTE: Enrollment time varies depending on the signal strength


between the device and the controller.

The device sends its unique MAC ID (Serial Number) and


Services information to the controller.
The controller registers the device and displays the
transmitter data on screen.
4. The LEDs light solid green for 3 seconds and the SiXFOB
emits a chirp to confirm enrollment.
5. Press the top two buttons again to complete enrollment.

3
(Loop 4)

10
45
20

30

LEDs flash alternately


Up to about 20 seconds

LEDs
ON for
3 seconds

5
Press the
buttons again
to complete
enrollment

6 Assign the desired Zone Type for each button key.


7 Assign a User Number for the Key Fob and press SAVE.
NOTE: Once enrolled in a system, the SiXFOB
cannot be used with another controller until it is
removed from the current controller. When
removed from a system, the key fob will revert to
factory default settings.

After enrolling, update the SiXCT firmware (via the


Controller) to ensure the latest version is used. See the
Controllers instructions.

*For SIA Installations


There are two methods to enroll the device when two-button press is required for Panic functions.
Method A (uses 8 zones in the system): Follow the directions above, except select Key Type 8 Button and program
Button Key 8 for the desired panic function. Continue the directions above to complete enrollment.
Method B (uses 6 zones in the system): Follow the direction above except select Key Type 6 Button. Continue the
directions above to assign the desired panic function to Button 6. Take note of the Zone number assigned to Button 6.
After assigning the User Number and selecting SAVE, enter Zone Programming mode. Scroll to the Button 6 Zone
number and reassign the Loop for Button 6 to Loop 5. Select SAVE.

System Status and Sounder Indications


The SiXFOB can be used to control the Lyric Controller system (e.g., arm, disarm the system); and receive system
status information (armed status, not ready to arm, in alarm, in RF transmission mode, and more). Press and release
any button and observe the key fob. Refer to the table below for system status information.

System Status Indications


G
G

20 sec

3 sec

System Status
Device Enrollment

R 2-3 sec

2x

System is Armed

4x

Alarm in progress or System in Audible Panic Mode

1x

Disarmed, Ready to Arm

2-3 sec

G 2-3 sec

2-3 sec

Disarmed, Not Ready to Arm

1x

RF Transmission
1 sec

Not Hearing from the Controller

2 sec

Deleting the Keyfob from the system


Sounder

LEDs
G = Green
R = Red

= On

= Slow Flash

= Rapid Flash

= LEDs Alternate

= Chirp

= Beep

Battery Replacement
When the battery is low, the LEDs do not flash during
transmission. To replace the battery:
1. Remove the screw from the back housing and use a
screwdriver to gently separate the front and back
housings.
2. Use a screwdriver to carefully remove the battery.
3. Wait 10 seconds or press a key fob button for 2
seconds to ensure full power discharge.
4. Insert a new Lithium, 3V, 210mAh battery as shown.
Recommended replacement battery:
Maxell CR2032 or Duracell DL2032
5. Replace the front housing and secure the housings
with the cover screw.

1
3
0

Wait about
10 seconds
30
or
press for 2 seconds
10

45

Maxell CR2032
Duracell DL2032

BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge,


disassemble, heat above 212 F (100 C) or incinerate. Dispose of used
batteries properly. Keep away from children.

Specifications:

Approval Listings:

Battery: Lithium, 3V, 210mAh; Maxell CR2032, Duracell DL2032


RF Frequency: 2.4GHz
Operating Temperature: 0 to 50 C / 32 to 122 F
(Agency compliance 0 to 49 C / 32 to 120 F)
Relative Humidity: 95% max. (Agency compliance 93% max.),
non-condensing
Dimensions: 11 mm H x 65.5 mm L x 36 mm W / 0.43 H x 2.58 L x 1.42 W

FCC / IC
cETLus Listed
Conforms to UL 1023 & UL 985
Certified to ULC ORD- C1023
& ULC-S545
Other Standards:
SIA CP-01 RoHS

C-Tick

Product must be tested at least once each


year.
2

IMPORTANT! This wireless key is intended as a convenience to the user and should not be considered as a life safety device.
IMPORTANT SECURITY NOTICE
Please inform the User about the security importance of their wireless key (key fob), and what to do if it is lost.
Explain that the key fob is similar to their keys or access card. If lost or stolen, another person can compromise their security
system. They should immediately notify the Dealer/Installer of a lost or stolen key fob. The Dealer/Installer will then remove the
key fob programming from the security system.

FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS


The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's
Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil est conforme la partie 15 des rgles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis
aux conditions suivantes: (1) Cet appareil ne doit pas causer dinterfrences nuisibles. (2) Cet appareil doit accepter toute interfrence
reue y compris les interfrences causant une reception indsirable.

RF EXPOSURE
Warning The antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or
transmitter except in accordance with FCC multi-transmitter product procedures.
MISE EN GARDE EXPOSITION AUX FREQUENCES RADIO
Attention L'antenne (s) utilis pour cet appareil ne doit pas tre co-localises ou oprant conjointement avec une autre antenne ou
metteur non conformant avec les procdures FCC poules produits multi-transmetteurs.

Support and Warranty


REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING
LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

For the latest documentation and online support information, please go to:
https://mywebtech.honeywell.com/
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa.
For patent information, see www.honeywell.com/patents

MyWebTech

Warranty

Patents

2014 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.

www.honeywell.com/security

2 Corporate Center Drive, Suite 100


P.O. Box 9040, Melville, NY 11747

DOC CODE 128B BAR CODE HERE


800-21339 11/15 Rev A

You might also like