Technical Announcement

IABU, DELTA ELECTRONICS, INC

WPLSoft

Product

PLC Division

Published by

Applicable
Model

Publisher

DVP Series

John Huang

Confidential Level

5 General
Classified
Top secret

ECN No.

N/A

Publication No.

PLC-01-EN-121107-01

Date of Publication

Nov. 7, 2012

Taiwan Sales, Product Manager, DGC, DEU, DPR, DES, DEJ

Published to

Object: Releasing WPLSoft version 2.31


Purpose: The functions which are added and the functions which are modified in WPLSoft
version 2.31 are described.
The functions which are added and the functions which are modified are described below.
1. The comparison instructions, the basic instructions which can be modified by
parameters, and ATMR are added.
A. Comparison instructions (API 296~313)
Format and description: LDZ S1 S2 S3
S1: Data source 1; S2: Data source 2; S3: Comparison value
S2 is subtracted from S1. The absolute value of the difference gotten is compared with
the absolute value of S3. Take API 296 (LDZ>) for example. If the comparison result is
that the absolute value of the difference gotten is larger than the absolute value of S3,
the condition of the instruction is met. If the comparison result is that the absolute
value of the difference gotten is less than the absolute value of S3, the condition of the
instruction is not met.
LDZ can be connected to a mother line directly.
API number 16-bit instruction 32-bit instruction
296
297
298
299
300
301
302
303
304
305
306
307
308

LDZ>
LDZ>=
LDZ<
LDZ<=
LDZ
LDZ<>
ANDZ>
ANDZ>=
ANDZ<
ANDZ<=
ANDZ
ANDZ<>
ORZ>

DLDZ>
DLDZ>=
DLDZ<
DLDZ<=
DLDZ
DLDZ<>
DANDZ>
DANDZ>=
DANDZ<
DANDZ<=
DANDZ
DANDZ<>
DORZ>

ON

|S1- S2| > |S3|


|S1- S2| |S3|
|S1- S2| < |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| > |S3|
|S1- S2| |S3|
|S1- S2| < |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| > |S3|

OFF

|S1- S2| |S3|


|S1- S2| < |S3|
|S1- S2| |S3|
|S1- S2| > |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| < |S3|
|S1- S2| |S3|
|S1- S2| > |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| |S3|

QUALITY
RELIABILITY
EXCELLENCE
1

ON

API number 16-bit instruction 32-bit instruction


309
310
311
312
313

ORZ>=
ORZ<
ORZ<=
ORZ
ORZ<>

DORZ>=
DORZ<
DORZ<=
DORZ
DORZ<>

OFF

|S1- S2| |S3|


|S1- S2| < |S3|
|S1- S2| |S3|
|S1- S2| |S3|
|S1- S2| |S3|

|S1- S2| < |S3|


|S1- S2| |S3|
|S1- S2| > |S3|
|S1- S2| |S3|
|S1- S2| |S3|

Example
D11 is subtracted from D10. If the absolute value of the difference gotten is larger than
K200, Y10 is ON. If the absolute value of the difference gotten is less than or equal to
K200, Y10 is OFF.
LDZ>

D10

D11

Y10

K200

B. Basic instructions which can be modified


A basic instruction can be modified by a parameter, e.g. LD M1@E1. The ladder diagram is
shown below.
Example

C. ATMR: Timer of the contact type


ATMR is the combination of AND and TMR. When the contact preceding ATMR is ON, the
timer specified measures time. If the value of the timer is the same as the setting value
(timer value>=setting value), the AND contact is ON. If the contact preceding ATMR is not
ON, the value of the timer is cleared.
Example
X0
ATMR

T5

K1000

Y0

D. Models which support these instructions:


Model
EH3
SV2
ES2/EX2 SS2
Version (above)
V1.40 V1.20
V3.20
V3.00

SA2
SX2
V2.60 V2.40

SE
V1.20

QUALITY
RELIABILITY
EXCELLENCE
2

2.

TP04P is supported.
TP04P does not support high-speed pulse output, the instructions FROM and TO, and the
instructions related to Modbus. Please refer to the user manual for more information.

3.

The simulator, wizard, and PLC Link are updated.


A. Simulator: The version of the simulator is 0.85. The simulator supports the instructions
listed above.
B. Wizard: The wizard in WPLSoft version 2.30 below is restored and updated.

Icon

Name
PID
High Speed Counter
High Speed Pulse Output
Communication Program
Positioning Control
Auxiliary Setup for
Extension Modules

Auxiliary setup for the extension modules

AIO modules

Auxiliary function for the sending of the message


by GSM MODEM
2-axis motion of the EH2/SV series PLC
Monitoring the temperature through the
communication.
Auxiliary function of the interrupt service
Monitoring the extension module through the
communication
Setting the AIO modules

LoadCell modules

Setting the LoadCell modules

Sending Message Setup


2-axis Motion Control
Temperature Monitor
Interrupt Service
Extension Module

Function
Auxiliary function of the PID instruction
Auxiliary function of the high-speed counter
Auxiliary function of the high-speed pulse output
Auxiliary function of the communication program
Auxiliary function of the position control

QUALITY
RELIABILITY
EXCELLENCE
3

C. PLC Link: The version of the PLC Link is 1.346. The PLC Link supports TP04P.

4. There are 50000 file registers in a DVP-EH3/DVP-SV2 series PLC.


Old software: There are inner file registers and memory card file registers in an EH3/SV2 series
PLC.

New software: The new software supports 50000 file registers. These file registers are
displayed in five pages. 10000 file registers in a page.

Models which support this function: DVP-EH3 version 1.40 and above, and DVPSV2 version
1.20 and above

QUALITY
RELIABILITY
EXCELLENCE
4

If Transmit in the first page is clicked, users


can set the number of data which will be read,
and the number of data which will be written.

If Transmit in the 2nd/3rd/4th/5th page is


clicked, the data in the 1000th~49999th will be
downloaded automatically, and users can set
the number of data which will be read.

These inner registers are stored in the memory in a PLC. The 10000th~49999th file registers are
latched file registers. The data in the 10000th~49999th file registers does not appear when the
battery runs down. If a memory card is inserted in a DVP-EH3 series PLC, the data in
10000th~49999th file registers will be stored in the memory card automatically. Users can copy
the parameters in the memory card into the PLC.

QUALITY
RELIABILITY
EXCELLENCE
5

5.

There are file registers in a DVP-ES2/DVP-EX2/DVP-SA2/DVP-SX2 series PLC.


A. There are 5000 file registers (0th~4999th file registers).
B. Models which support these files registers
z
DVP-ES2/EX2: Firmware version 2.80 and above
z
DVP-SA2: Firmware version V2.60 and above
z
DVP-SX2: Firmware version V2.40

QUALITY
RELIABILITY
EXCELLENCE
6

6.

The device comment list varies with the model selected.


After the model in the Select drop-down list box is changed, the Warning window will
appear. If users click Yes, the current device comment list will be cleared (including the
comments that the users type), and the device comment list for the new model will be
loaded. If the users click NO, the device comment list will be not changed.

Example: After the model in the model set drop-down list box is changed from EH3 to ES2,
the result will be as shown below.

QUALITY
RELIABILITY
EXCELLENCE
7

7.

VFD-E series AC motor drives support the setting of the number of times the
password can be typed.
A VFD-E series AC motor drive whose firmware version is 1.2 or above supports the setting
of the number of times the password can be typed.

After users set the number of times the password can be typed, the remaining number of
times the password can be typed will be shown if the program is downloaded or uploaded.

8.

There is no limit on the number of lines in a ladder diagram.


In WPLSoft version 2.30 and below, there are at most 2000 lines in a ladder diagram. In this
new version of WPLSoft, there is no such limit.

Download the software:


http://www.delta.com.tw/product/em/download/download_main.asp?act=3&pid=3&cid=1&tpid=3