PANEL BOX
b
a
b
ab
ab a
abc
b
a
1500
2000
2500
1250
1250
2000
10500
3000
10000
3000
1500
1500
ab
575
2000
2000
1000
8575
3500
2500
2500
1500 1000
575
2000
2000
8575
3500
1000 1200
1500
2300
2000
2500
1500
500
CONVENIENCE
OUTLET
150mm FROM
CENTER OF
DEVICE TO
COUNTER TOP
ELECTRICAL SYMBOL
LEGEND
SYMBOL
DESCRIPTION
CONVENIENCE OUTLET
500
REF
2500
2500
W.M.
RANGE
W.M.
7 RANGE
PIN LIGHT
2500
1250
1250
2500
1250
1250
10500
3000
REF
10000
3000
1500
1500
MAIN LIGHTING
FIXTURE
ab
abc
2000
1500
2000
1000
SERVICE DROP
2-#8 THHN
60 AMP
MAIN
BREAKER
POWER SERVICE
ENTRANCE CAP
2-#8 THHN
2-#8 THHN IN
15 AMP
15 AMP
15 AMP
20 AMP
20 AMP
20 AMP
20 AMP
20 AMP
20 AMP
SPARE
10
WIRE GUTTER
0.20x0.15x0.40 M
SURFACE TYPE
MOUNTED COVER
ELECTRIC KW- HR
METER BASE
METER
PANEL
BOX
TO GROUND CONDUCTOR
GROUND LINE
300mm
CONVENIENCE
OUTLET
1.
ALL ELECTRICAL WORKS AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF
THE PHILIPPINE ELECTRICAL
CODE WITH THE RULES AND REGULATIONS OF THE NATIONAL AND LOCAL AUTHORITIES
CONCERNED.
2.
SERVICE VOLTAGE TO THE BUILDING SHALL BE 220 V, 60 HTZ SINGLE PHASE TWO WIRE SYSTEM.
3.
THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF THE CONCRETE TERMINAL POLE FOR
POWER SUPPLY AND
TELEPHONE SERVICE.
4.
ALL INSTALLATIONS SHALL BE CONCEALED, WIRING SHALL BE INCASED IN PVC PIPE SCHED. 40. POWER AND
TELEPHONE SERVICES SHALL BE
INCASED IN RSC.
5.
MINIMUM WIRE AND CONDUIT SIZE SHALL BE NO. 12 AWG TYPE, TW AND 21 " DIAMETER PVC TRADE SIZE
RESPECTIVELY UNLESS OTHERWISE
SPECIFIED.
6.
PULL BOXES OF APPROXIMATE SIZE SHALL BE PROVIDED EVEN IF NOT INDICATED IN THE
DRAWINGS TO ACCOMMODATE THE NUMBERS OF THE SPLICES OF WIRES.
7.
ALL FLUORESCENT LAMPS SHALL BE PROVIDED WITH POLYESTER-FILLED PRE-HEAT, THERMALLY PROTECTED HIGH
POWER BALLAST.
8.
ALL MATERIALS TO BE USED SHALL BE NEW AND OF APPROVED TYPE APPROPRIATE FORBOTH LOCATION AND
INTENDED USE.
9.
LIGHT CONTROL SWITCHES SHALL BE RATED 10a, 300W AND SHALL NOT CARRY A LOAD GREATERTHAN 50a,
DUPLEX RECEPTACLES SHALL BE RATED 10a, 250V, ROUNDED SLOTS FOR 220 AND PARALLEL SLOTS FOR 15a
OR250VAS REQUIRED.
10. FOR EACH SPARE CIRCUIT, PROVIDE EMPTY 43'' DIAMETER RISER TERMINATING IN A 2-1/8'' DEEP BY 4" OCTAGONAL
BOX ABOVE CEILING.
11.
ELECTRICAL INSTALLATION SHALL BE SUPERVISED BY A DULY LICENSED ENGINEER OR A REGISTERED MASTER
ELECTRICIAN.
12.
OUTLET BOXES SHALL BE AS FOLLOWS:
PANEL BOX
CIRCUIT HOMERUN
COUNTER TOP
2 POLE
SECONDARY RACK
RANGE
OUTLET
600mm FROM CENTER OF
DEVICE TO FIN. FLR LINE
2500
2500
WIRE
CONDUIT
CKT LIGHTING CONVENIENCE WATT/ TOTAL
PROTECTION
VOLTS AMPERE SIZE
NO. OUTLET
SIZE(PVC)
OUTLET
OUTLET WATTS
220
5
15 AMP
#14 THHN
100
1200
12
1
220
5
15 AMP
2
#14 THHN
12
100
1200
220
5
15 AMP
#14 THHN
3
12
100
1200
10
220
20
AMP
4
#12
THHN
200
800
4 (DUPLEX)
3
10
220
20 AMP
5
#12 THHN
200
800
4 (DUPLEX)
3
10
220
20 AMP
#12
THHN
6
200
4 (DUPLEX)
800
3
25
1000
20 AMP
#10THHN
7
1000 220
1 (DUPLEX)
6
25
220
1000
20 AMP
#10THHN
1000
8
1 (DUPLEX)
6
25
1000
20 AMP
#10THHN
9
1000 220
1 (DUPLEX)
6
10
SPARE
9000 220
37.5
TOTAL:
1000
2500
1500 1000
8575
3500
1000 1200
1500
2000
2000
500
575
8575
3500
2500
LIGHT OUTLETS
RECEPTACLES &
TELEPHONE OUTLETS
RANGE OUTLET
2-1/8" DEEP 4-1/16" SQUARE BOX WITH 1-GANG RAISED PLASTIC COVER
13.
NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT PRIOR KNOWLEDGE AND APPROVAL OF THE DESIGNER
AND THE OWNER, ANY SUCH REVISION DONE
WITHOUT APPROVAL SHALL CAUSE RESPONSIBILITY OF THE
DESIGNER TO CEASE AS WHOLE.