You are on page 1of 92

EDVN041311

Split Type
Air Conditioners
FTKS-G Series
Cooling Only

1.
2.
3.
4.

FTKS25GVMV
FTKS35GVMV
FTKS50GVMV
FTKS60GVMV
FTKS71GVMV

RKS25GVMV
RKS35GVMV
RKS50GVMV
RKS60GVMV
RKS71GVMV

Power Supply ..........................................................................................2


Functions.................................................................................................3
Specifications ..........................................................................................4
Dimensions .............................................................................................7
4.1 Indoor Unit................................................................................................7
4.2 Outdoor Unit .............................................................................................9

5. Wiring Diagrams....................................................................................11
5.1 Indoor Unit..............................................................................................11
5.2 Outdoor Unit ...........................................................................................12

6. Piping Diagrams....................................................................................14
6.1 Indoor Unit..............................................................................................14
6.2 Outdoor Unit ...........................................................................................15

7. Capacity Tables ....................................................................................17


7.1 Cooling Only...........................................................................................17
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ............................................................................................20

8. Operation Limit......................................................................................21
9. Sound Level ..........................................................................................22
9.1 Measuring Location ................................................................................22
9.2 Indoor Unit..............................................................................................23
9.3 Outdoor Unit ...........................................................................................24

10.Electric Characteristics..........................................................................25
11.Installation Manual ................................................................................26
11.1
11.2
11.3
11.4

Safety Precautions .................................................................................26


25/35 Class ............................................................................................27
50/60 Class ............................................................................................36
71 Class .................................................................................................45

12.Operation Manual..................................................................................54
13.Optional Accessories ............................................................................83
13.1
13.2
13.3
13.4

Option List ..............................................................................................83


<KPW937A4> Air Direction Adjustment Grille........................................84
<KPW945A4> Air Direction Adjustment Grille........................................85
<KKP945A4> Drain Plug........................................................................86

Split Type Air Conditioners FTKS-G Series

Power Supply

EDVN041311

1. Power Supply

Note:

Indoor Unit

Outdoor Unit

FTKS25GVMV

RKS25GVMV

FTKS35GVMV

RKS35GVMV

FTKS50GVMV

RKS50GVMV

FTKS60GVMV

RKS60GVMV

FTKS71GVMV

RKS71GVMV

Power Supply

1 , 220 ~ 240 V, 50 Hz
1 , 220 ~ 230 V, 60 Hz

Power Supply Intake ; Outdoor Unit

Split Type Air Conditioners FTKS-G Series

EDVN041311

Functions

Basic
Function

Operation limit for cooling (CDB)

19.4
~ 46

19.4
~ 46

Operation limit for heating (CWB)

PAM control

Standby electricity saving

Compressor

Oval scroll compressor

Comfortable
Airflow

Comfort
Control

Operation

Functions

Inverter
(with inverter power control)

FTKS50/60/71GVMV
RKS50/60/71GVMV

FTKS50/60/71GVMV
RKS50/60/71GVMV

Category

FTKS25/35GVMV
RKS25/35GVMV

FTKS25/35GVMV
RKS25/35GVMV

2. Functions

Air-purifying filter

Photocatalytic deodorising filter

Air-purifying filter with photocatalytic


deodorising function

Titanium apatite photocatalytic


air-purifying filter

z
z

Category

Health &
Clean

Functions

Swing compressor

Air filter (prefilter)

Rotary compressor

Wipe-clean flat panel

Reluctance DC motor

Washable grille

Power-airflow flap

MOULD PROOF operation

Power-airflow dual flaps

Heating dry operation

Power-airflow diffuser

Wide-angle louvres

Vertical auto-swing (up and down)

Horizontal auto-swing (right and left)

3-D airflow

COMFORT AIRFLOW operation

Auto fan speed

Indoor unit quiet operation

NIGHT QUIET mode (automatic)

OUTDOOR UNIT QUIET operation


(manual)

Timer

Good-sleep cooling operation

24-hour ON/OFF TIMER

NIGHT SET mode

Worry Free Auto-restart (after power failure)


Reliability &
Self-diagnosis (digital, LED) display
Durability
Wiring error check function

Flexibility

Anti-corrosion treatment of outdoor


heat exchanger

Multi-split / split type compatible indoor


unit

Flexible power supply correspondence

10 m

10 m

INTELLIGENT EYE operation

Chargeless

Quick warming function

Either side drain (right or left)

Hot-start function

Power selection

Automatic defrosting

5-room centralised controller (option)

Remote
Control

Automatic operation

Remote control adaptor


(normal open pulse contact) (option)

Programme dry operation

Remote control adaptor


(normal open contact) (option)

Fan only

DIII-NET compatible
(adaptor) (option)

Wireless

Wired

Lifestyle
New POWERFUL operation
Convenience (non-Inverter)
Inverter POWERFUL operation

Priority-room setting

COOL / HEAT mode lock

HOME LEAVE operation

ECONO operation

Indoor unit [ON/OFF] button

Signal receiving sign

Temperature display

Remote
Controller

Note: z : Available
: Not available

Split Type Air Conditioners FTKS-G Series

Specifications

EDVN041311

3. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Model

Indoor Unit
Outdoor Unit

Capacity Rated (Min. ~ Max.)


Moisture Removal
Running Current (Rated)
Power Consumption
(Rated)
Power Factor (Rated)
COP Rated (Min. ~ Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure H / M / L / SL
Level
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure H / SL
Level
Sound Power
H
Level
Drawing No.

Note:

FTKS25GVMV
RKS25GVMV
2.5 (1.2 ~ 3.3)
8,500 (4,100 ~ 11,300)
2,150 (1,030 ~ 2,840)
1.2
3.4 - 3.2 - 3.1 / 3.4 - 3.2

kW
Btu/h
kcal/h
L/h
A

FTKS35GVMV
RKS35GVMV
3.3 (1.3 ~ 4.2)
11,300 (4,400 ~ 14,300)
2,840 (1,120 ~ 3,610)
1.9
4.4 - 4.2 - 4.0 / 4.4 - 4.2

583

892

%
W/W
mm
mm
mm

77.9 - 79.2 - 78.4 / 77.9 - 79.2


4.29
6.4
9.5
18.0
Both Liquid and Gas Pipes
20
15
10

92.1 - 92.3 - 92.9 / 92.1 - 92.3


3.70
6.4
9.5
18.0
Both Liquid and Gas Pipes
20
15
10

m
m
m
g/m

20

20

mm
mm
kg
kg

FTKS25GVMV
White
9.0 (318)
7.4 (261)
5.5 (194)
4.4 (155)
Cross Flow Fan
40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.17 - 0.16 - 0.15 / 0.17 - 0.16
35
93.6 - 95.1 - 97.2 / 93.6 - 95.1
Microcomputer Control
283 800 195
265 855 340
9
12

FTKS35GVMV
White
8.9 (314)
7.4 (261)
5.6 (198)
4.6 (162)
Cross Flow Fan
40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.19 - 0.18 - 0.17 / 0.19 - 0.18
40
95.7 - 96.6 - 98.0 / 95.7 - 96.6
Microcomputer Control
283 800 195
265 855 340
9
12

dB(A)

37 / 31 / 25 / 22

38 / 32 / 26 / 23

W
A
W
%
A
mm
mm
kg
kg

RKS25GVMV
Ivory White
Hermetically Sealed Swing Type
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
31.8 (1,123)
23.4 (826)
Propeller
50
3.23 - 3.04 - 2.95 / 3.23 - 3.04
548
77.1 - 78.4 - 77.4 / 77.1 - 78.4
3.5
550 765 285
589 882 363
34
38

RKS35GVMV
Ivory White
Hermetically Sealed Swing Type
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
31.8 (1,123)
23.9 (845)
Propeller
50
4.21 - 4.02 - 3.83 / 4.21 - 4.02
852
92.0 - 92.1 - 92.7 / 92.0 - 92.1
4.9
550 765 285
589 882 363
34
38

dB(A)

46 / 43

47 / 44

m/min
(cfm)

W
Steps

A
W
%

W
L
kg
m/min
(cfm)

dB

60

61

3D083684

3D083685

The data are based on the conditions shown in the table below.

Cooling

Piping Length

Conversion Formulae

Indoor ; 27CDB / 19CWB


Outdoor ; 35CDB / 24CWB

7.5 m

kcal/h = kW 860
Btu/h = kW 3412
cfm = m/min 35.3

Split Type Air Conditioners FTKS-G Series

EDVN041311

Specifications

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Model

Indoor Unit
Outdoor Unit

Capacity Rated (Min. ~ Max.)


Moisture Removal
Running Current (Rated)
Power Consumption
(Rated)
Power Factor (Rated)
COP Rated (Min. ~ Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure H / M / L / SL
Level
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure H / SL
Level
Sound Power
H
Level
Drawing No.

Note:

FTKS50GVMV
RKS50GVMV
5.2 (1.9 ~ 6.3)
17,700 (6,500 ~ 21,500)
4,300 (1,630 ~ 5,420)
2.9
6.4 - 6.2 - 5.9 / 6.4 - 6.2

kW
Btu/h
kcal/h
L/h
A

FTKS60GVMV
RKS60GVMV
6.0 (1.9 ~ 7.1)
20,500 (6,500 ~ 24,200)
5,160 (1,630 ~ 6,110)
3.9
8.4 - 8.0 - 7.7 / 8.4 - 8.0

1,397

1,765

%
W/W
mm
mm
mm

99.2 - 98.0 - 98.7 / 99.2 - 98.0


3.72
6.4
12.7
18.0
Both Liquid and Gas Pipes
30
20
10

95.5 - 96.0 - 95.5 / 95.5 - 96.0


3.40
6.4
12.7
18.0
Both Liquid and Gas Pipes
30
20
10

m
m
m
g/m

20

20

mm
mm
kg
kg

FTKS50GVMV
White
14.3 (504)
12.4 (437)
10.1 (356)
9.0 (317)
Cross Flow Fan
43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.19 - 0.18 - 0.18 / 0.19 - 0.18
34
81.3 - 82.1 - 78.7 / 81.3 - 82.1
Microcomputer Control
290 1,050 250
361 1,145 364
12
17

FTKS60GVMV
White
15.4 (544)
13.5 (478)
11.4 (402)
9.9 (350)
Cross Flow Fan
43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.21 - 0.20 - 0.19 / 0.21 - 0.20
40
86.6 - 87.0 - 87.7 / 86.6 - 87.0
Microcomputer Control
290 1,050 250
361 1,145 364
12
17

dB(A)

43 / 39 / 34 / 31

45 / 40 / 35 / 32

W
A
W
%
A
mm
mm
kg
kg

RKS50GVMV
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.650
R-410A
1.5
49.5 (1,748)
45.8 (1,617)
Propeller
53
6.21 - 6.02 - 5.72 / 6.21 - 6.02
1,363
99.8 - 98.4 - 99.3 / 99.8 - 98.4
7.4
735 825 300
784 960 390
43
48

RKS60GVMV
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.650
R-410A
1.5
54.0 (1,907)
48.9 (1,727)
Propeller
53
8.19 - 7.80 - 7.51 / 8.19 - 7.80
1,725
95.7 - 96.2 - 95.7 / 95.7 - 96.2
9.4
735 825 300
784 960 390
43
48

dB(A)

48 / 44

52 / 46

m/min
(cfm)

W
Steps

A
W
%

W
L
kg
m/min
(cfm)

dB

62

66

3D083687A

3D083688

The data are based on the conditions shown in the table below.

Cooling

Piping Length

Conversion Formulae

Indoor ; 27CDB / 19CWB


Outdoor ; 35CDB / 24CWB

7.5 m

kcal/h = kW 860
Btu/h = kW 3412
cfm = m/min 35.3

Split Type Air Conditioners FTKS-G Series

Specifications

EDVN041311

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Model

Indoor Unit
Outdoor Unit

Capacity Rated (Min. ~ Max.)


Moisture Removal
Running Current (Rated)
Power Consumption
(Rated)
Power Factor (Rated)
COP Rated (Min. ~ Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure H / M / L / SL
Level
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H W D)
Packaged Dimensions (H W D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure H / SL
Level
Sound Power
H
Level
Drawing No.

Note:

FTKS71GVMV
RKS71GVMV
7.1 (2.5 ~ 8.7)
24,200 (8,500 ~ 29,700)
6,110 (2,150 ~ 7,480)
4.5
10.4 - 10.0 - 9.6 / 10.4 - 10.0

kW
Btu/h
kcal/h
L/h
A
W

2,283

%
W/W
mm
mm
mm

99.8 - 99.3 - 99.0 / 99.8 - 99.3


3.11
6.4
15.9
18.0
Both Liquid and Gas Pipes
30
20
10

m
m
m
g/m

20

mm
mm
kg
kg

FTKS71GVMV
White
16.3 (575)
14.3 (505)
11.7 (413)
10.7 (377)
Cross Flow Fan
43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable, Washable, Mildew Proof
0.21 - 0.21 - 0.20 / 0.21 - 0.21
45
97.4 - 93.2 - 93.8 / 97.4 - 93.2
Microcomputer Control
290 1,050 250
361 1,145 364
12
17

dB(A)

46 / 42 / 37 / 34

m/min
(cfm)

W
Steps

A
W
%

W
A
W
%
A
mm
mm
kg
kg

RKS71GVMV
Ivory White
Hermetically Sealed Swing Type
2YC63BXD
1,920
FVC50K
0.750
R-410A
1.9
61.4 (2,168)
50.6 (1,787)
Propeller
66
10.19 - 9.80 - 9.40 / 10.19 - 9.80
2,238
99.8 - 99.3 - 99.2 / 99.8 - 99.3
11.4
770 900 320
900 925 390
60
70

dB(A)

52 / 49

W
L
kg
m/min
(cfm)

dB

66
3D083689

The data are based on the conditions shown in the table below.

Cooling

Piping Length

Conversion Formulae

Indoor ; 27CDB / 19CWB


Outdoor ; 35CDB / 24CWB

7.5 m

kcal/h = kW 860
Btu/h = kW 3412
cfm = m/min 35.3

Split Type Air Conditioners FTKS-G Series

EDVN041311

Dimensions

4. Dimensions
4.1

Indoor Unit

FTKS25/35GVMV

3D083432B

THE MARK () SHOWS PIPING DIRECTION

AIRFLOW (INDOOR)
(FOR PERFORMANCE AND MAINTENANCE)

1050
REAR

RIGHT

INCLUDING
INSTALLATION PLATE
252
250

MIN.30

REAR

LEFT

290

MIN.50
MODEL NAME (SPACE FOR
MAINTENANCE)
PLATE

BOTTOM

FRONT GRILLE FIXING SCREWS


(INSIDE)
SIGNAL RECEIVER

(SPACE FOR
PERFORMANCE)

FTKS50/60GVMV

MIN.50
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

TERMINAL BLOCK WITH


EARTH TERMINAL
(INSIDE)

INTELLIGENT EYE SENSOR


OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP

GAS PIPE 12.7 CuT


(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 430)

DRAIN HOSE FOR VP13


(CONNECTING PART
I.D.14.0, O.D.18.0)
(THE HOSE LENGTH OF
LIQUID PIPE 6.4 CuT
OUTSIDE THE UNIT:
(THE LENGTH OF PIPE OUTSIDE
ABOUT 530)
THE UNIT: ABOUT 480)

INDOOR UNIT ON/OFF SWITCH


ROOM TEMP. THERMISTOR (INSIDE)
MODEL NAME PLATE

BLADE ANGLES

40 10

35

40

VERTICAL BLADE (AUTOMATIC)

(ARC433A92)

50

5
55

55

Split Type Air Conditioners FTKS-G Series

50

60
WALL HOLE FOR
EMBEDDED PIPING
80 HOLE

99.5

STANDARD LOCATIONS OF WALL HOLES

52

30

35

FAN

WIRELESS REMOTE CONTROLLER

52.5

155.5

DRY

10
(163)

1050
893.5

COOLING

290

HORIZONTAL BLADE
(AUTOMATIC)

52

(58)

14.5

FLAPS
SIGNAL
TRANSMITTER
(18)

WALL HOLE
80 HOLE

3D083423A

Dimensions

EDVN041311

THE MARK () SHOWS PIPING DIRECTION

AIRFLOW (INDOOR)
(FOR PERFORMANCE AND MAINTENANCE)

1050
REAR

RIGHT

INCLUDING
INSTALLATION PLATE

MIN.30

REAR

LEFT

(SPACE FOR
PERFORMANCE)

FTKS71GVMV

252
250
MIN.50

290

MODEL NAME (SPACE FOR


PLATE
MAINTENANCE)

BOTTOM

FRONT GRILLE FIXING SCREWS


(INSIDE)
SIGNAL RECEIVER

MIN.50
(SPACE FOR
MAINTENANCE)

REQUIRED SPACE

TERMINAL BLOCK WITH


EARTH TERMINAL
(INSIDE)

INTELLIGENT EYE SENSOR


OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP

GAS PIPE 15.9 CuT


(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 430)

DRAIN HOSE FOR VP13


(CONNECTING PART
I.D.14.0, O.D.18.0)
(THE HOSE LENGTH OF
LIQUID PIPE 6.4 CuT
OUTSIDE THE UNIT:
(THE LENGTH OF PIPE OUTSIDE
ABOUT 530)
THE UNIT: ABOUT 480)

INDOOR UNIT ON/OFF SWITCH


ROOM TEMP. THERMISTOR (INSIDE)

BLADE ANGLES

40 10

35

40

60

50

5
55

55

50

WALL HOLE FOR


EMBEDDED PIPING
80 HOLE

99.5

STANDARD LOCATIONS OF WALL HOLES

52

VERTICAL BLADE (AUTOMATIC)

(ARC433A92)

30

35

FAN

WIRELESS REMOTE CONTROLLER

52.5

155.5

DRY

10
(163)

1050
893.5

COOLING

290

HORIZONTAL BLADE
(AUTOMATIC)

14.5

(18)

(58)

MODEL NAME PLATE

FLAPS

52

SIGNAL
TRANSMITTER

WALL HOLE
80 HOLE

3D083788

Split Type Air Conditioners FTKS-G Series

EDVN041311

4.2

Dimensions

Outdoor Unit

DRAIN OUTLET
(I.D. 15.9 HOSE FOR CONNECTION)

MINIMUM SPACE FOR AIR PASSAGE

4-HOLES FOR ANCHOR BOLTS


(M8 OR M10)
105.5

574

150

50

50

50

100

50

300

100

13

490

29.5

311

WALL HEIGHT ON AIR OUTLET SIDE


= LESS THAN 1200

150

RKS25/35GVMV

HANDLE

BRAND NAME LABEL


285

12

765

63
OUTDOOR AIR THERMISTOR
MANUFACTURE'S
LABEL

LIQUID
STOP VALVE
(6.4 CuT)

105

SERVICE
PORT

165

550

WIRING
INLET

22

196
IN CASE OF REMOVING
STOP VALVE COVER

GAS STOP VALVE


(9.5 CuT)

3D083535

DRAIN OUTLET
(I.D. 15.9 HOSE FOR CONNECTION)
825

WALL HEIGHT ON AIR OUTLET SIDE


= LESS THAN 1200

MINIMUM SPACE FOR AIR PASSAGE

100

RKS50/60GVMV

78

350

580

50

50

350

100

330

300

IN CASE OF REMOVING
STOP VALVE COVER

25

10

350

50

NAME PLATE
BRAND NAME PLATE

WIRING INLET

OUTDOOR AIR TEMPERATURE


THERMISTOR

TERMINAL STRIP
WITH EARTH TERMINAL

89 64

735

4-HOLES FOR ANCHOR BOLTS


(M8 OR M10)

350

36

124

100

325

LIQUID STOP VALVE


(6.4 CuT)
SERVICE PORT

155
160

18
30
GAS STOP VALVE
(12.7 CuT)

3D083536

Split Type Air Conditioners FTKS-G Series

Dimensions

EDVN041311

RKS71GVMV
MINIMUM SPACE FOR AIR PASSAGE
900
4-CUTS FOR ANCHOR BOLTS
(M12)

WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 1200

100
350

191

350
100

50

30

376

380

320
350
(345~355)

102 71
117
30

45

50

350

140

100

620

DRAIN OUTLET
I.D. 25 HOSE FOR CONNECTION

NAME PLATE

GAS STOP VALVE


TERMINAL STRIP
WITH EARTH TERMINAL
LIQUID STOP VALVE

OUTDOOR AIR
THERMISTOR

126

50
78
108

104

INTERCONNECTING PIPING
AND WIRING INLET

90

410

770

BRAND NAME LABEL

50

GAS PIPE
(15.9 SINGLE UNION)

30
67

LIQUID PIPE
(6.4 SINGLE UNION)

3D083534

10

Split Type Air Conditioners FTKS-G Series

EDVN041311

Wiring Diagrams

5. Wiring Diagrams
5.1

Indoor Unit

FTKS25/35GVMV

3D078575A

FTKS50/60/71GVMV

3D078578B

Split Type Air Conditioners FTKS-G Series

11

Wiring Diagrams

5.2

EDVN041311

Outdoor Unit

RKS25/35GVMV

3D078579A

RKS50/60GVMV

3D083060A

12

Split Type Air Conditioners FTKS-G Series

EDVN041311

Wiring Diagrams

RKS71GVMV

3D083062A

Split Type Air Conditioners FTKS-G Series

13

Piping Diagrams

EDVN041311

6. Piping Diagrams
6.1

Indoor Unit

FTKS25/35GVMV

FTKS50/60GVMV

INDOOR UNIT
MUFFLER ASSY
HEAT EXCHANGER
7.0 CuT

7.9 CuT

6.4 CuT

FIELD PIPING
(6.4 CuT)

THERMISTOR
ON HEAT EXCH.

6.4 CuT
6.4 CuT

CROSS FLOW FAN

M
FAN MOTOR

FIELD PIPING
(9.5 CuT)

9.5 CuT

REFRIGERANT FLOW
COOLING

4D083433B

4D083425A

FTKS71GVMV

FIELD PIPING
(6.4 CuT)
FIELD PIPING
(15.9 CuT)

14

Split Type Air Conditioners FTKS-G Series

EDVN041311

6.2

Piping Diagrams

Outdoor Unit

RKS25/35GVMV

3D083542

RKS50/60GVMV

3D083543

Split Type Air Conditioners FTKS-G Series

15

Piping Diagrams

EDVN041311

RKS71GVMV

3D083544

16

Split Type Air Conditioners FTKS-G Series

EDVN041311

Capacity Tables

7. Capacity Tables
7.1

Cooling Only

FTKS25GVMV + RKS25GVMV (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)


AFR

9.0

BF

0.24

INDOOR
EWB

EDB

OUTDOOR TEMPERATURE (CDB)


20

25

30

32

35

40

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

2.46

1.90

0.45

2.35

1.84

0.49

2.23

1.79

0.54

2.28

1.81

0.55

2.21

1.78

0.58

2.10

1.72

0.62

16.0

22

2.57

1.87

0.45

2.46

1.82

0.50

2.34

1.76

0.54

2.40

1.79

0.55

2.33

1.76

0.58

2.21

1.71

0.62

18.0

25

2.68

1.97

0.45

2.57

1.92

0.50

2.46

1.87

0.54

2.51

1.90

0.56

2.44

1.87

0.58

2.33

1.82

0.62

19.0

27

2.73

2.08

0.46

2.62

2.04

0.50

2.51

1.99

0.54

2.57

2.02

0.56

2.50

1.99

0.58

2.38

1.94

0.63

22.0

30

2.90

2.01

0.46

2.79

1.97

0.50

2.68

1.93

0.55

2.74

1.96

0.56

2.67

1.93

0.59

2.56

1.89

0.63

24.0

32

3.01

1.96

0.46

2.90

1.93

0.51

2.79

1.89

0.55

2.86

1.91

0.56

2.79

1.89

0.59

2.67

1.85

0.63

Symbols:

Note:

AFR

: Airflow rate

BF

: Bypass factor

(m/min.)

EWB

: Entering wet bulb temp.

(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
(Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m

3D083981

FTKS35GVMV + RKS35GVMV (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)


AFR

8.9

BF

0.24

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB

EDB

20

25

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

2.64

1.98

0.60

2.64

1.98

0.68

2.64

1.98

0.77

2.64

1.98

0.78

2.64

1.98

0.83

2.64

1.98

0.92

16.0

22

3.39

2.25

0.69

3.24

2.18

0.76

3.10

2.11

0.82

3.16

2.14

0.85

3.07

2.10

0.89

2.92

2.02

0.95

18.0

25

3.54

2.34

0.70

3.39

2.27

0.76

3.24

2.20

0.83

3.32

2.24

0.85

3.22

2.20

0.89

3.07

2.13

0.96

19.0

27

3.61

2.45

0.70

3.46

2.38

0.76

3.31

2.32

0.83

3.39

2.35

0.85

3.30

2.31

0.89

3.15

2.25

0.96

22.0

30

3.83

2.36

0.70

3.68

2.30

0.77

3.53

2.24

0.84

3.62

2.27

0.86

3.53

2.24

0.90

3.37

2.18

0.96

24.0

32

3.97

2.29

0.71

3.83

2.23

0.77

3.68

2.18

0.84

3.77

2.22

0.86

3.68

2.18

0.90

3.53

2.13

0.97

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

30

32

35

40

Note:
(m/min.)

EWB

: Entering wet bulb temp.

(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
(Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m

3D083982

Split Type Air Conditioners FTKS-G Series

17

Capacity Tables

EDVN041311

FTKS50GVMV + RKS50GVMV (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)


AFR

14.3

BF

0.14

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB

EDB

20

25

TC

SHC

PI

TC

SHC

PI

TC

SHC

30
PI

TC

SHC

32
PI

TC

SHC

35
PI

TC

SHC

40
PI

14.0

20

5.11

3.76

1.08

4.88

3.64

1.18

4.65

3.53

1.29

4.75

3.58

1.32

4.60

3.50

1.38

4.36

3.38

1.48

16.0

22

5.34

3.69

1.08

5.11

3.58

1.19

4.88

3.47

1.29

4.99

3.53

1.33

4.84

3.46

1.39

4.60

3.35

1.49

18.0

25

5.57

3.86

1.09

5.34

3.76

1.19

5.11

3.66

1.30

5.23

3.71

1.33

5.08

3.65

1.39

4.84

3.54

1.50

19.0

27

5.69

4.07

1.09

5.45

3.97

1.20

5.22

3.87

1.30

5.35

3.92

1.34

5.20

3.86

1.40

4.96

3.76

1.50

22.0

30

6.03

3.92

1.10

5.80

3.84

1.21

5.57

3.75

1.31

5.70

3.80

1.34

5.56

3.75

1.41

5.32

3.66

1.51

24.0

32

6.26

3.82

1.11

6.03

3.74

1.21

5.80

3.66

1.32

5.94

3.71

1.35

5.80

3.66

1.41

5.56

3.58

1.52

Symbols:

Note:

AFR

: Airflow rate

BF

: Bypass factor

(m/min.)

EWB

: Entering wet bulb temp.

(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
(Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m

3D083983

FTKS60GVMV + RKS60GVMV (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)


AFR

15.4

BF

0.14

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB

EDB

20

25

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

TC

SHC

PI

14.0

20

5.90

4.25

1.36

5.63

4.11

1.49

5.36

3.98

1.62

5.48

4.03

1.67

5.31

3.95

1.75

5.03

3.81

1.88

16.0

22

6.16

4.18

1.37

5.90

4.05

1.50

5.63

3.92

1.63

5.75

3.98

1.68

5.59

3.90

1.75

5.31

3.77

1.88

18.0

25

6.43

4.35

1.38

6.16

4.23

1.51

5.89

4.11

1.64

6.03

4.17

1.68

5.86

4.10

1.76

5.58

3.98

1.89

19.0

27

6.56

4.57

1.38

6.29

4.46

1.51

6.03

4.34

1.64

6.17

4.40

1.69

6.00

4.33

1.77

5.72

4.21

1.90

22.0

30

6.96

4.40

1.39

6.69

4.30

1.52

6.42

4.20

1.66

6.58

4.26

1.70

6.41

4.19

1.78

6.14

4.09

1.91

24.0

32

7.23

4.28

1.40

6.96

4.19

1.53

6.69

4.09

1.66

6.86

4.15

1.71

6.69

4.09

1.78

6.41

4.00

1.91

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

EWB

: Entering wet bulb temp.

30

32

35

40

Note:
(m/min.)
(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
(Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m

3D083984A

18

Split Type Air Conditioners FTKS-G Series

EDVN041311

Capacity Tables

FTKS71GVMV + RKS71GVMV (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)


AFR

16.3

BF

0.08

INDOOR

OUTDOOR TEMPERATURE (CDB)

EWB

EDB

20

25

TC

SHC

PI

TC

SHC

PI

TC

SHC

30
PI

TC

SHC

32
PI

TC

SHC

35
PI

TC

SHC

40
PI

14.0

20

6.98

4.97

1.76

6.66

4.81

1.93

6.35

4.64

2.10

6.48

4.71

2.16

6.28

4.61

2.26

5.95

4.44

2.43

16.0

22

7.29

4.88

1.77

6.98

4.73

1.94

6.66

4.57

2.11

6.81

4.65

2.17

6.61

4.55

2.27

6.28

4.39

2.44

18.0

25

7.61

5.08

1.78

7.29

4.94

1.95

6.97

4.79

2.12

7.13

4.86

2.18

6.94

4.78

2.28

6.61

4.63

2.45

19.0

27

7.76

5.33

1.79

7.45

5.19

1.96

7.13

5.05

2.13

7.30

5.12

2.18

7.10

5.03

2.28

6.77

4.89

2.45

22.0

30

8.24

5.12

1.80

7.92

5.00

1.97

7.60

4.88

2.14

7.79

4.95

2.20

7.59

4.87

2.30

7.26

4.75

2.47

24.0

32

8.55

4.98

1.81

8.23

4.86

1.98

7.92

4.75

2.15

8.12

4.82

2.21

7.92

4.75

2.31

7.59

4.64

2.48

Symbols:
AFR

: Airflow rate

BF

: Bypass factor

Note:
(m/min.)

EWB

: Entering wet bulb temp.

(C)

EDB

: Entering dry bulb temp.

(C)

TC

: Total capacity

(kW)

SHC

: Sensible heat capacity

(kW)

PI

: Power input

(kW)

1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
(Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m

3D083985

Split Type Air Conditioners FTKS-G Series

19

Capacity Tables

7.2

EDVN041311

Capacity Correction Factor by the Length of Refrigerant Piping (Reference)


The cooling capacity of the unit has to be corrected in accordance with the length of refrigerant piping
the distance between the indoor unit and the outdoor unit.

7.2.1

25/35 Class

7.2.2

50 Class

7.2.3

60/71 Class

Note:
20

The graphs show the factor when additional refrigerant of the proper quantity is charged.
Split Type Air Conditioners FTKS-G Series

EDVN041311

Operation Limit

8. Operation Limit
RKS25/35/50/60/71GVMV

4D083533

Split Type Air Conditioners FTKS-G Series

21

Sound Level

EDVN041311

9. Sound Level
9.1

Measuring Location
Indoor Unit

Note:

1. Operation sound is measured in an anechoic chamber.


2. The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27CDB / 19CWB
Outdoor ; 35CDB / 24CWB

22

Outdoor Unit

Piping Length
5m

Split Type Air Conditioners FTKS-G Series

EDVN041311

9.2

Sound Level

Indoor Unit

FTKS25GVMV

FTKS35GVMV

4D083736A

FTKS50GVMV

FTKS60GVMV

70

60
NC-60

43

34

(B.G.N IS ALREADY RECTIFIED)


50
OPERATING CONDITIONS

NC-50

POWER SOURCE 220-240/220-230v 50/60Hz


JIS STANDARD

40
NC-40
30
NC-30

220-240/220-230v

50/60Hz (H)

220-240/220-230v

50/60Hz (L)

Cooling

20

63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

NC-20
8000

OVER ALL (dB)

NC-70

50/60Hz
50/60Hz
SCALE 220-240/220-230V 220-240/220-230V
(H)
(L)

4D083738

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

70

OVER ALL (dB)

NC-70

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE

4D083737A

50/60Hz
50/60Hz
SCALE 220-240/220-230V 220-240/220-230V
(H)
(L)

60
NC-60

45

35

(B.G.N IS ALREADY RECTIFIED)


50
NC-50

OPERATING CONDITIONS
POWER SOURCE 220-240/220-230v 50/60Hz
JIS STANDARD

40
NC-40
30
NC-30

220-240/220-230v

50/60Hz (H)

220-240/220-230v

50/60Hz (L)

Cooling

20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

NC-20
8000

4D083739

FTKS71GVMV

4D083740

Split Type Air Conditioners FTKS-G Series

23

Sound Level

Outdoor Unit

RKS25GVMV

RKS35GVMV

70

NC-60

SCALE

50/60Hz
220-240/220-230V

46

(B.G.N IS ALREADY RECTIFIED)


50
OPERATING CONDITIONS

NC-50

POWER SOURCE 220-240/220-230V 50/60 Hz


JIS STANDARD (JIS9612)

40
NC-40

Cooling

30
NC-30
20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

47

(B.G.N IS ALREADY RECTIFIED)


OPERATING CONDITIONS

NC-50

POWER SOURCE 220-240/220-230V 50/60Hz


JIS STANDARD (JIS9612)

40
NC-40

Cooling

30
NC-30

20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

NC-20

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

60
NC-60

SCALE

50/60Hz
220-240/220-230V

48

(B.G.N IS ALREADY RECTIFIED)


50
OPERATING CONDITIONS

NC-50

POWER SOURCE 220-240/220-230V 50/60Hz


JIS STANDARD (JIS9612)

40
NC-40

70

OVER ALL (dB)

NC-70

Cooling

30
NC-30
20

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

50/60Hz
220-240/220-230V

8000

4D083742

RKS60GVMV

70

63

NC-60

SCALE

50

4D083741

RKS50GVMV

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE

60

NC-20
8000

OVER ALL (dB)

NC-70
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

60

70

OVER ALL (dB)

NC-70

NC-20
8000

4D083743

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

9.3

EDVN041311

OVER ALL (dB)

NC-70

60
NC-60

SCALE

50/60Hz
220-240/220-230V

52

(B.G.N IS ALREADY RECTIFIED)


50
NC-50

OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz
JIS STANDARD (JIS9612)

40
NC-40

Cooling

30
NC-30
20

APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63
125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

NC-20
8000

4D083744

RKS71GVMV
70

OVER ALL (dB)

OCTAVE BAND SOUND PRESSURE LEVEL


dB (0dB=0.0002 bar)

NC-70

60
NC-60

50/60Hz
220-240/220-230V

52

(B.G.N IS ALREADY RECTIFIED)


50
NC-50

OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz
JIS STANDARD (JIS9612)

40
NC-40

Cooling

30
NC-30
20
APPROXIMATE
THRESHOLD HEARING
FOR CONTINUOUS
NOISE
63

24

SCALE

125
250
500 1000 2000 4000
OCTAVE BAND CENTER FREQUENCY (Hz)

NC-20
8000

4D083745

Split Type Air Conditioners FTKS-G Series

EDVN041311

Electric Characteristics

10. Electric Characteristics


Indoor Unit

Outdoor Unit

Power supply
Hz - Volts

Voltage range

Compressor
MCA

MFA

RHz

50 - 220
50 - 230
FTKS25GVMV

RKS25GVMV

60 - 230

FTKS35GVMV

RKS35GVMV

9.75

10

47

60 - 220

FTKS50GVMV

RKS50GVMV

60 - 230

FTKS60GVMV

RKS60GVMV

10

68

60 - 230

FTKS71GVMV

RKS71GVMV

60 - 230

0.14

3.5

50

0.20

40

0.14

53

0.19

43

0.17

53

0.20

43

0.19

66

0.31

43

0.20

3.6

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

5.8
13.5

15

63

5.6
6.0

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

5.8
7.7

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

7.3
13.5

15

76

7.0
7.7

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

7.3
9.5

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

50 - 240
60 - 220

40

6.0

50 - 220
50 - 230

0.20

3.8

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

50 - 240
60 - 220

50

3.6
9.75

50 - 220
50 - 230

2.5
2.6

Max. 50 Hz, 264 V


Min. 50 Hz, 198 V

50 - 240
60 - 220

FLA

3.8

50 - 220
50 - 230

2.8

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

50 - 240
60 - 230

IFM

FLA

2.6

50 - 220
50 - 230

OFM
W

2.8
Max. 50 Hz, 264 V
Min. 50 Hz, 198 V

50 - 240
60 - 220

RLA

9.1
17.5

20

54

8.7
9.5

Max. 60 Hz, 253 V


Min. 60 Hz, 198 V

9.1

Symbols:

Note:

MCA

: Min. circuit amps (A)

MFA

: Max. fuse amps (A)

1. RLA is based on the following conditions.


Indoor temp. 27CDB / 19CWB
Outdoor temp. 35CDB.
2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. Be sure to install an earth leak detector. (One that can handle
higher harmonics.)
(This unit uses an inverter, which means that it must be used an
earth leak detector capable handling high harmonics in order to
prevent malfunctioning of the earth leak detector.)

RHz

: Rated operating frequency (Hz)

RLA

: Rated load amps (A)

OFM

: Outdoor fan motor

IFM

: Indoor fan motor

: Fan motor rated output (W)

FLA

: Full load amps (A)

3D083368

Split Type Air Conditioners FTKS-G Series

25

Installation Manual

EDVN041311

11. Installation Manual


11.1 Safety Precautions

26

Split Type Air Conditioners FTKS-G Series

EDVN041311

Installation Manual

11.2 25/35 Class

Split Type Air Conditioners FTKS-G Series

27

Installation Manual

28

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

29

Installation Manual

30

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

31

Installation Manual

32

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

33

Installation Manual

34

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Installation Manual

3P344163-4

Split Type Air Conditioners FTKS-G Series

35

Installation Manual

EDVN041311

11.3 50/60 Class

36

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

37

Installation Manual

38

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

39

Installation Manual

40

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

41

Installation Manual

42

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

43

Installation Manual

EDVN041311

3P344163-5

44

Split Type Air Conditioners FTKS-G Series

EDVN041311

Installation Manual

11.4 71 Class

Split Type Air Conditioners FTKS-G Series

45

Installation Manual

46

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

47

Installation Manual

48

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

49

Installation Manual

50

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Installation Manual

51

Installation Manual

52

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Installation Manual

3P344163-6

Split Type Air Conditioners FTKS-G Series

53

Operation Manual

EDVN041311

12. Operation Manual

54

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

55

Operation Manual

56

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

57

Operation Manual

58

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

59

Operation Manual

60

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

61

Operation Manual

62

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

63

Operation Manual

64

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

65

Operation Manual

66

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

67

Operation Manual

68

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

69

Operation Manual

70

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

71

Operation Manual

72

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

73

Operation Manual

74

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

75

Operation Manual

76

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

77

Operation Manual

78

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

79

Operation Manual

80

EDVN041311

Split Type Air Conditioners FTKS-G Series

EDVN041311

Split Type Air Conditioners FTKS-G Series

Operation Manual

81

Operation Manual

EDVN041311

3P344162-2

82

Split Type Air Conditioners FTKS-G Series

EDVN041311

Optional Accessories

13. Optional Accessories


13.1 Option List
13.1.1 Indoor Unit
Option Name

Note:

25/35/50/60/71 Class

Titanium Apatite Photocatalytic Air-Purifying Filter


(without Frame)

KAF970A46

Remote Controller Loss Prevention with Chain

KKF917A4

Standard accessory

13.1.2 Outdoor Unit


Option Name
1

Air Direction Adjustment Grille

Drain Plug

Split Type Air Conditioners FTKS-G Series

25/35 Class

50/60 Class

KPW937A4
KKP937A4

71 Class

KPW945A4
KKP945A4

83

Optional Accessories

EDVN041311

13.2 <KPW937A4> Air Direction Adjustment Grille


Q Before Installation
Checking the parts

Check the following parts


Name

Louver

Installation manual

Shape

Quantity

With 4 screws
1piece

1piece

Q Installation Procedure
Selection of Installation Location
Use when installing in a location that meets the following conditions.
zWhen installing near the border to a neighbor's house
zIf exhaust blows directly on passers-by because outdoor unit is installed facing a road.
zChanging the fan direction of the outdoor unit to prevent it blowing directly on shrubbery, etc.

Installation of Louver
zInstallation is possible in the four directions:
upward, downward, rightward, and leftward.
zThe installation screws are attached to the louver.
zFirst temporarily attach the louver with 4 screws,
then check that the angle is correct, and finally
tighten the screws fully.

Prepared hole
pitch 435mm
Fan partition
Part A
(see figure below)
Prepared hole
pitch 435mm
Fan partition

CAUTION
1.Install so that a short circuit is prevented.
2.For the use in snowy regions, avoid installation
with the air outlet facing upward. Install so that
the air outlet faces leftward, rightward, or downward.
Snow accumulates in the air outlet of the outdoor
unit, causing malfunction of the main body of the
outdoor unit.
3.Be advised that if the fan direction is up,
dead leaves and other foreign matter
easily accumulates in the exhaust vent.

The prepared hole is in between the grating


of the grille. Part A (prepared hole) cross
section (the shape of either a or b)

a) Grille grating

Prepared hole

b) Grille grating

Prepared hole

4P104499-1A

84

Split Type Air Conditioners FTKS-G Series

EDVN041311

Optional Accessories

13.3 <KPW945A4> Air Direction Adjustment Grille


Before installation
Check the following parts

Name

Louver

Truss tapping screw

Installation manual

1piece

M44screws(max.7.5kW class)
M54screws(8.0/9.0kW class)

1piece

Shape

Quantity

Installation Procedure
Selection of Installation Location
Use when installing in a location that meets the following conditions.
O When installing near the border to a neighbor's house
O If exhaust blows directly on passers-by because outdoor unit is installed facing a road.
O If exhaust blows directly on vegetation

Space Needed for Installation


O

A minimum of 100mm is needed


between the back of the outdoor
unit and any obstructions
(walls, etc.)
m

t
ore

han

100

Installation of Louvers
Caution
Attach the louvers overlapping the standard grille.
Installing the louvers without the grille would allow hands to enter the fan area,
which is dangerous, so be sure to install the standard grille.
When pointing up

When pointing down

(1) Remove the 4 attachment screws from


the standard grille.

(1) Remove the 4 attachment screws from


the standard grille.

(2) Install the louver pointed up.

(2) Install the louver pointed down.

O
O

Overlap the standard grille and


screw both in together.
The attachment screws
are in the louvers.

(3) Installation complete

Overlap the standard grille and


screw both in together.
O The attachment screws
are in the louvers.
O

(3) Installation complete

3P089958-2C

Split Type Air Conditioners FTKS-G Series

85

Optional Accessories

EDVN041311

13.4 <KKP945A4> Drain Plug

3P089958-1B

86

Split Type Air Conditioners FTKS-G Series