Professional Documents
Culture Documents
Issue: 2
A25000-A900-A32-2-76P1
C55160.01--00
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT
LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR
THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2009. All rights reserved.
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
Table of Contents
This document has 10 pages.
1
1.1
1.2
1.3
1.4
1.5
1.6
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
Generic Information
Dimension of Flexi Outdoor Case
Standard tools
8 mm Allen key
TX 10 screwdriver for M3 screw
TX 25 screwdriver for M5 screw
7 mm spanner and 13 mm spanner
Adjustable wrench (56 to 64 mm)
Fish tape and Thread locking compound
(medium strength non-permanent)
roof. When installing the product, wear a safety harness and other relevant protective gear. In addition, follow all occupational health and safety regulations applicable to the installation.
Minimum clearances
Wall measurements
Top min 30 mm
min 105 mm
measured from
back cover
(needed for fresh
air)
min 145 mm
measured
from plinth
Front min 600 mm
To side min 400 mm
To side min 75 mm
Front min 600 mm
Plinth
Preparation of installation
1.The cable output must be placed
depending on the installation needs. This
evaluation must be made before starting
the installation procedure.
2. Besides the type of the IDU, its placement into the FOC should be considered.
The installation technician is charged to
choose how the IDU must be installed.
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
Bottom
a1
b
b
1.2
Plint h
min
250 mm
(9.8 in.)
Fan maintenance
space from the back
145 mm (5.7 in.)
13.5 (4 pcs)
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
1.3
Hole Numbering
g Note that the blue safety washers hold the screws in place during installation. They
should be installed to the screws after the screws are through the bracket.
g Before mounting the outdoor case on the pole, install the IDU. The IDU can be
installed after having placed FOC on the pole. Do not connect the cables before
having carried out the lifting of the IDU on the pole.
Back-to-back Installation
g A second unit can be installed back to back using the same brackets. And
maximum 2 units can be stacked on the pole.
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
1.4
1.5
Connect the grouding cable to the IDU before inserting the IDU into the case. Make sure
that the fans power supply cables can be easily reached for their successive connection
to fan controller board.
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
Before connecting the cables, the plate has to be fixed to the inner cover by 4 M3
screws. And the plate has not to be removed any more.
A25000-A900-A32-2-76P1
Issue: 2 Issue date: September 2009
1.6
Final Operation
Final taping