You are on page 1of 9

NO

Parameter
GENERAL INFORMATION

Physical Dimensions

Environmental

Hazardous Area Approvals

Analysis Power

Battery and Charging

Frequency Analysisi

Data Storage Capacity

Data Analysis Sped

Input Signals

10

Full scale input level


(Accel Channels A, B, C, D; Volts A,
B, C, D)

11

Four-Channel Data Collection

11

Four-Channel Data Collection

12

In-field Route Analysis Tools

13

Input sensor types

14

Tachometer input

15

Advance Acquisitions

16

Wireless

17

Warranty

18

Connection to a PC or Laptop

DESCRIPTION
Manufacturer
Computational System Incorporate, Emerson
Model
Dimensions
Weight
LCD display
Keypad
Built-in stand
Operating Temperature
Long-term Storage Temperature
Long-term Storage Temperature
Environmental Rating

Infield Analysis

Waveform Analysis
Bearing/Gear Fault Detection
Battery type

A/D converter
Automatic Integrator Correction
Averaging modes
Cursors Spectrum
Dynamic range
Frequency range
Frequency Units
Full-scale range
Noise floor
Number of averages
Resolution

Response
Scaling
Windows
Internal memory
External memory
400 line, 1000 HZ spectrum
1600 line, 1000 Hz spectrum

Accelerometer Input

Volts Input
Input Impedance

Fault frequency overlays on plot


Parameter trends
Colored alarms
Waveform autocorrelation
Portable sensors

Installed sensors
RPM range
Tach input level
PeakVue
Pseudo tach
Demodulation
2.0 Class 2 (optional)
Wi-Fi

Connections/Output
Compatible software

SPECIFICATION
CSI
Type
_
8.8 (248 mm) high, 1.57 (40 mm) deep, 8.9 (226 mm) wide
3.95 lbs (1.79 kg)
6 x 4.5 (151 x 115 mm) color TFT w/ LED backlight.
Resolution 640 x 480 pixels. Touchscreen - XY resistive.
Tactile Dome buttons, 12 tactile dome buttons with backlit keys,
Electroluminescent panel illumination
-4 to 122 F (-20 to 50 C)
-4 to 95 F (-20C to 35 C) with battery
-40 to 150 F (-40C to 65 C) without battery
Sealed enclosure, IP-65 rated
FM and CSA Class 1 Division 2 Groups (A, B, C, D)
ATEX and IECEx Zone 2, CE EXII 3G, nA nC IIC T4
High Frequency Analysis WizardHigh Resolution Analysis Wizard
Low Frequency Analysis WizardOrder Tracking Analysis WizardSynchronous Time Analysis WizardBump Test - Machine Running WizardBump Test - Machine Stopped WizardCoastdown (peak-hold and peak/phase)
Wizard with Bode & Cascade standardTurning Speed Detection (vibration and laser) WizardRotor Fault Detection WizardCross Channel Phase, ORBITOrbit Analysis WizardTrending analysis in field from previous data taken
ODS and Modal AnalysisAdvance transient analysis
Waveform Alarming & Waveform Auto-correlation,
waveform filtering Analysis
PeakVue /Demodulation/ Enveloping with Trendable
bearing parameter & waveform fault SEVERITY
Rechargeable Lithium-Ion battery pack
7.2 Volts (Nominal) Protected Output
On pack LED readout
10+ hours of continuous use
4 hours recharge time (Nominal)
Charging temperature 32 to 95 F (0 to 35 C)

24 bits of precision.
Allows precise measurement of low frequency
vibrations down to 0.2 Hz.
Normal, exponential, peak hold, order tracking,
negative averaging, synchronous time
Single, Harmonic, Moving Harmonic, Sideband, and
Time/Frequency for waveform.
Converter has 120 dB dynamic range.
DC to 10 Hz minimum, DC to 80 kHz maximum
Hz, CPM, Orders.
Accelerometer input: 0-20V, Volts input -20V + 20V
Typically less than 20 V for a 400-line spectrum
at 1000 Hz maximum frequency.
5,000 in Route mode, 10,000 in Job mode.
100, 200, 400, 800, 1600, 3200, 6400, or 12800 lines of resolution.
True Zoom provides
effective resolution of up to 300,000 lines.
Flat to DC for non-integrated and DC-coupled signals;
optional AC coupling -3 dB at 1 Hz
Linear or Log, both X and Y.
Hanning or uniform
1 GB
SD (Secure Digital). Virtually unlimited memory
with off the shelf SDHC SD cards up to 32 GB
67% overlap 6 avg/sec
67% overlap 3 avg/sec
A 2-milliampere, 20-volt (nominal), constant-current power supply
inside
the analyzer powers sensors such as accelerometers connected to
the accelerometer channel inputs.
0-20V
Full scale vibration level is +/- 90 gs
when using a 100-mV/g accelerometer
-20V to +20V
Greater than 125K ohms
Simultaneous 4-channels Dynamic Input + Phase
Simultaneous 4-channels DC Input
Simultaneous 4-channel Route collection + Phase
Simultaneous 4-channel Display - Spectrum and Waveform
Simultaneous 4-channel Transient + Phase
Simultaneous 4-channel ODS/Modal + Phase
Simultaneous 4-channel Volt/Displacement + Phase
(for sleeve bearing monitoring)

Simultaneous Dual Orbits Display [accelerometer/displacement]


(for rolling element/sleeve bearing monitoring)
Simultaneous 4-channel Cross Channel + Phase
Identifies source of vibration peaks
Up to 12 parameters trended over 2+ years
Shows specific parameter in alarm and percentage
of alarm value
Identifies whether impacting is periodic or random
Accelerometers, velocity probes, RPM/tachometer probes,
temperature sensors, flux coil, current clamp, pressure sensors,
triaxial accelerometer, impact hammer
Any vibration or dynamic sensor with a voltage output;
any DC-type signal.
1 to 100,000 RPM
TTL input, built in conditioning for non-TTL signals,
adjustable trigger level. The tachometer
Selectable filters
Generates tach pulses for hidden shafts.
Selectable filters
Range up to 10 meters
802.11 b/g
Range up to 33 meters
12 months Indonesia support and Product Warranty.
USB 2.0, 100M Ethernet.
AMS Suite: Machinery Manager v5.6 or greater.
Refer to www.assetweb.com/mhm under AMS Machinery Manager
software for most currently operating requirements.

You might also like