You are on page 1of 1

Calculation

Reference

Figure 5.A1

Nearest major town :


Seberang Perai fall under :
Project Area :
Terrain :
% of Impervious Area :

Output
KUALA KANGSAR
Region 1
0.11 ha
LOWLYING, SLOPE 1 : 2000 TO 1 : 5000
90%

Table 5.A1

Permissible Site Discharge (PSD)/ha :


For area of 0.11 ha, PSD = 0.11x65.5 =

65.50 l/s/ha
7.21 l/s
0.007 cu.m/s

Table 5.A1

Site Storage Requirement (SSR)/ha :


For area of 0.11 ha, SSR = 0.11x540.4 =

540.40 cu. m/ha


59.44 cu. m

Table 5.A2

Inlet Flow/ha:
For area of 0.11 ha, Inlet Flow = 0.11x190 =

190.00 l/s/ha
20.90 l/s
0.021 cu.m/s

Table 5.A2

PSD/ha :
For area of 0.11 ha, PSD = 0.11x48.7 =

48.70 l/s/ha
5.36 l/s
0.005 cu.m/s

Table 5.A2

SSR/ha :
For area of 0.11 ha, SSR = 0.11x540 =

540.00 cu. m/ha


59.40 cu. m

Smaller PSD value is adopted for subsequent sizing of outlet pipe


Thus, PSD =

0.005 cu.m/s

Table 5.A3

Inlet Pipe :

174 mm dia.

take Inlet Pipe size :

200 mm dia.

Outlet Pipe :

65 mm dia.

take Outlet Pipe size :

100 mm dia.

Table 5.A4

Inlet Pipe: (with Inlet Flow of 0.0209 m3/sec)


take Inlet Pipe size :

248 mm dia.
250 mm dia.

Table 5.A4

Outlet Pipe: (with PSD of 0.005 m3/sec)


take Outlet Pipe size :

236 mm dia.
250 mm dia.

PSD:
(whichever is smaller from Table 5.A1 and 5.A2)

0.005 cu.m/s

Table 5.A3

SSR:
(whichever is larger from Table 5.A1 and 5.A2)
Sizing of OSD Tank:
The required storage is 59.444 cu. m
Adopt tank :
Width
12.00 m
Length
20.00 m
Depth
1.20 m

59.44 cu. m

288.00 cu. m
ok

Inlet Pipe:
(whichever is smaller from Table 5.A3 and 5.A4)

200 mm dia.

Outlet Pipe:
(whichever is smaller from Table 5.A3 and 5.A4)

100 mm dia.