You are on page 1of 37

Main-Remote Installation Products Overview

DESCRIPTION

Page 1 of 37

16/1551-LZA 701 0003 Uen A

Main-Remote Installation Products Overview


Copyright
Copyright Ericsson AB 2009. All rights reserved.
Disclaimer
No part of this document may be reproduced in any form without the written permission of the
copyright owner.
The contents of this document are subject to revision without notice due to continued progress in
methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of
any kind resulting from the use of this document.

Contents
1

Introduction

2
2.1
2.2
2.3

Main-Remote RBS Systems


WCDMA RBS Systems
GSM RBS Systems
External Units

3
3.1
3.2

Power Systems
PBC-02 Systems
SSC-01

4
4.1
4.2

Site Transmission
TMR 9302
MPH

5
5.1
5.2
5.3
5.4
5.5
5.6

Cables
Optical Cables
Power Cables
Jumper Cables
TG Synchronization Cables for GMS
RET Control Cables
Grounding Kit Cables

6
6.1
6.2
6.3
6.4

Installation Materials
Antenna Support Products
Cable Support and Accessories
Tools and Instruments
Miscellaneous Products

7
7.1
7.2
7.3
7.4

Type Sites
Type Site 1 Type Site 2 Type Site 3 Type Site 4 -

Outdoor Greenfield Site


Greenfield Shelter Site
Rooftop Indoor Site
Rooftop Outdoor Site

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

7.5
7.6

Type Site 5 - Rooftop Shelter Site


Type Site 6 - Rooftop Outdoor Site

Terms and Abbreviations

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

Page 2 of 37

6/21/2013

Main-Remote Installation Products Overview

Page 3 of 37

1 Introduction
This document is an overview of products for a main-remote site.
The products can be used, for example, at the following site types:

Greenfield

Rooftop

Indoor/In-building

For further information see documents;

Installation Material Overview, EN/LZT 751 0049

Implementation Team Products Overview, EN/LZT 751 0065

Optical Interface Link, 15/1531-LZA 701 0003

2 Main-Remote RBS Systems


This section describes the units in WCDMA and GSM Main-Remote RBS systems.
The main-remote system contains a Main Unit (MU) and one or more Remote Radio Units (RRU).
The MU supplies power to the system and the RRUs contains the radio equipment. Each RRU is
installed near the antenna and connected directly to the MU by an Optical Interface Link (OIL)
cable. The short distance between the RRU and the antenna reduces feeder loss, thereby lowering
power consumption.

2.1 WCDMA RBS Systems


2.1.1

RBS 3518 Main Unit

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 1
Table 1

Page 4 of 37

RBS 3518 Main Unit


RBS 3518 Main Unit Specifications

Dimensions (WDH)

483102381 mm

Weight

33 kg

Operating temperature

-33C to +50C

Input power options

-48 V DC
100250 V AC

Typical power consumption

0.10 kW (DC)
0.11 kW (AC)

Optical interface

LC

DC power interface

Screw terminal

AC power interface

Screw terminal

Installation options

Floor, wall, pole, or tower

Capacity

Up to six RRUs

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

2.1.2

Page 5 of 37

RBS 3418 Main Unit, Indoor

Note that the RBS 3418 main unit also is a part of the RBS 3018.

Figure 2
Table 2

RBS 3418 Main Unit


RBS 3418 Main Unit Specifications

Dimensions (WDH)

483271177 mm

Max. weight

20.5 kg

Operating temperature

+5C to +50C

Input power options

-48 V DC
+24 V DC
100250 V AC

Typical power consumption

0.10 kW (-48 V DC)


0.12 kW (+48 V DC)
0.12 kW (+24 V AC)

Optical interface

LC

DC power interface

Screw terminal

AC power interface

Screw terminal

Installation options

19-inch rack

Capacity

Up to six RRUs

Space requirement in 19-inch rack

4-5 U

2.1.3

RRU22 20 W

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 3
Table 3

Page 6 of 37

RRU22 20 W
RRU22 20 W Specifications

Dimensions (WDH)

365286470 mm

Max. weight

29.2 kg

Operating temperature

-33C to +50C

Input power options

-48 V DC
100250 V AC (with external PSU)

Typical power consumption

0.14 kW (DC)
1.09 kW (AC)

Optical interface

ODC

DC power interface

ODC

AC power interface

Screw terminal in external PSU

RF interface

7-16

RET interface

4-pin N12

Installation options

Wall, pole, or tower

Capacity

One carrier 20 W or
Two carriers 10 W

2.1.4

RRU22 40 W

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 4
Table 4

Page 7 of 37

RRU22 40 W
RRU22 40 W Specifications

Dimensions (WDH)

365292571 mm

Max. weight

33.6 kg

Operating temperature

-33C to +50C

Input power options

-48 V DC
100250 V AC

Typical power consumption

0.23 kW (DC)
0.26 kW (AC)

Optical interface

ODC

DC power interface

ODC

AC power interface

Screw terminal in external PSU

RF interface

7-16

RET interface

7-16 (RF interface)

Installation options

Wall, pole, or tower

Capacity

One carrier 40 W or
Two carriers 20 W

2.1.5

RRUW-01 60 W

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 5
Table 5

Page 8 of 37

RRUW-01 60 W
Remote Radio Unit Wideband (RRUW) -01 60 W Specifications

Dimensions (WDH)

383169636 mm

Weight

20 kg

Operating temperature

-33C to +50C

Input power

-48 V DC
100250 V AC

Typical power consumption

0.22 kW

Optical interface

LC

DC power interface

Screw terminal

AC power interface

Screw terminal

RF interface

7-16

RET interface

8-pole DIN

Installation options

Wall, pole, or tower

Capacity

One carrier 60 W or
Two carriers 30 W

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 9 of 37

2.2 GSM RBS Systems


2.2.1

RBS 2111 Main Unit, MU 12

Figure 6
Table 6

RBS 2111 Main Unit


RBS 2111 Main Unit Specifications

Dimensions (WDH)

460143373 mm

Weight

6.8 kg

Operating temperature

-33 C to +50 C

Input power options

-48 V DC
100250 V AC (with external PSU)

Typical power consumption

0.01 kW
0.09 kW with heater

Optical interface

SC

DC power interface

Screw terminal

AC power interface

Screw terminal

Installation options

Wall, pole, tower, or 19-inch rack

Capacity

Up to three RRUs

Space requirement in a 19-inch rack

2U

2.2.2

RRUN

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 7
Table 7

Page 10 of 37

RRUN
RRUN Specifications

Dimensions (WDH)

372239433 mm

Weight

16.5 kg

Operating temperature

-33 C to +50 C

Input power

-48 V DC
100250 V AC (with external PSU)

Typical power consumption

0.16 kW (GSM 800/900)


0.18 kW (GSM 1800/1900)

Optical interface

SC

DC power interface

Screw terminal

AC power interface

Screw terminal in external PSU

RF interface

N-type

Installation options

Wall, pole, or tower

Capacity

2 Transceivers (TRX)

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 11 of 37

2.3 External Units


2.3.1

RETU

Figure 8
Table 8

RETU
Remote Electrical Tilt Unit (RETU) Specifications

Dimensions (WDH)

5060178 (KRY 121 63/1)


5958251 (KRY 121 67/x)

Antenna connection interface

Screw terminal

RRU interface

4 pole connector

Installation

On the antenna

Description

Adjusts electrical down tilt in an antenna by


mechanically turning the antenna phase shifters

2.3.2

PSU

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 9
Table 9

Page 12 of 37

PSU
Power Supply Unit (PSU) Specifications

Specification PSU (RRU


22)

PSU (RRUW-01)

PSU-AC-1 (RRUN)

Application

RRU22

RRUW-01

RRUN

Dimensions
(WDH)

18068330 230390140 mm
mm

25532070 mm

Weight

3.8 kg

3.8 kg

5.6 kg

Operating
temperature

-33 C to
+50 C

-33 C to +50 C

-33 C to +50 C

Input power

100250 V
AC

100250 V AC

100250 V AC

Output power -48 V DC

-48 V DC

-48 V DC

AC interface

ODC (AC)

ODC (AC)

Screw terminal

DC interface

ODC

Open end

Screw terminal

Description

Converts incoming AC power to DC power

2.3.3

ACCU

Figure 10
Table 10

ACCU
Alternating Current Connection Unit (ACCU) Specifications

Application

RRUW-01 and RRU22 with external PSU

Dimensions
(WDH)

110180130 mm

Max. weight

1.6 kg

Operating
temperature

-33 C to +50 C

Input/output power

100250 V AC

AC input interface

Screw terminal

AC output interface

ODC (AC)

Description

Distributes over current protected power to the PSU; required in outdoor


sites with PSU

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 13 of 37

3 Power Systems
3.1 PBC-02 Systems

Figure 11 Wall mounted PBC-02 Main Unit, Battery Unit (BU) 2, and Pole-Mounted PBC-02 Main
Unit with PBC-02 Battery Unit (Double Unit) 1
Table 11

Power and Battery Cabinet-02 (PBC-02) Unit Specifications

Specification

PBC-02 MU

PBC-02 BU2

PBC-02 MU +
BU1 (Double
Unit)

PBC-02 MU +
BU1 + BU2

Dimensions
(WDH mm)

450220570

450220570

450400570

450400570 +
450220570

Max. weight

54 kg incl.
battery

65 kg incl.
battery

119 kg incl.
battery

184 kg incl.
battery

Operating temperature

-33 C to +45 C

Input Power

90275 V AC

Output voltage

-48 V DC

Max. power consumption 1.35 kW

1.35 kW

Battery capacity

26 or 39 Ah

13 Ah

26 or 39 Ah

Cooling

Convection

Installation options

Wall or pole

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

52 or 65 Ah

6/21/2013

Main-Remote Installation Products Overview

Page 14 of 37

3.2 SSC-01
The Site Support Cabinet (SSC) is an outdoor cabinet that supports both the RBS 2111 MU and the
RBS 3418 MU. It can hold all power equipment, batteries, up to two MUs, and includes space for
transmission equipment. The SSC is a flexible product that can be ordered according to the needs
of customer. See document SSC-01 Technical Product Description, 11/1551-LZA 701 0003, for
more information.

Figure 12
Table 12

SSC-01
SSC-01 Specifications

Dimensions (WDH)

6508701400 mm

Max. weight

515 kg

Operation temperature

-33 C to +50 C

Output voltage

-48 V DC

Typical power consumption at ambient temperature +25 C

1.6 TW

Batteries

Max. 200 Ah

Cooling

Air condition

Space

Up to 13 U

Capacity

GSM 34 or
WCDMA 61 or
GSM 32 + WCDMA 31

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 15 of 37

4 Site Transmission
4.1 TMR 9302

Figure 13
Table 13

TMR 9302
Transmission Rack (TMR) 9302 Specifications

Dimensions (WDH)

445470740 mm

Weight

27 kg (excluding microwave equipment)

Space

6U, holds up to AMM 6p

Operating temperature

-25 C to +55 C

Input power

-48 V DC
100250 V AC (with external PSU)

Max. power consumption

420 W

Cooling

Fans

Installation options

Wall or pole

4.2 MPH

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 14
Table 14

Page 16 of 37

MPH
Modem Protective Housing (MPH) Specifications

Dimensions (WDH)

340135620 mm

Weight

12 kg (excluding microwave equipment)

Space

Can be used to house an AMM 1p or AMM 2p

Operating temperature

-25 C to +50 C (-25 C to +55 C for 2 MMU2)

Input power options

-48 V DC
+24 V DC
100250 V AC (with external PSU)

Max. power consumption

200 W

Cooling

Cooling fins

Installation options

Wall or pole

5 Cables
5.1 Optical Cables

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 15
Table 15

Page 17 of 37

Optical Cable Connector Types without Protective Covers


Optical Cable Specifications

Application

Connector

Length (m)

RRU22 to
RBS 3018,
RBS 3418, or
RBS 3518

LCODC

1, 5, 10, 20, 50, 70, 80, TSR 899 113/L


100, 150, 200, 250, 350,
500

RRUW-01 to
RBS 3018,
RBS 3418, or
RBS 3518

LCLC

5, 10, 20, 50, 70, 100,


150, 250

RPM 253 3577/L

RRUN to
RBS 2111

SCSC

20, 50, 100, 500

TSR 899 088/L

Adapter when replacing


RRU22 with RRUW-01

LCODC (f)

RPM 253 4388/1000

Extension cable RRU22

ODCODC (f)

10, 25

TSR 899 145/L

Cascade RRUW-01 to
RRUW-01

LCLC

2, 5, 10, 20, 100

RPM 253 2895/L

Cascade RRUW-01 to
RRU22

LCODC

2, 5, 10, 20

RPM 253 2788/L

(1)

Product Number(1)

L = defined length of cable.

5.2 Power Cables

Figure 16

Power Cable Connectors Without Protective Covers

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 18 of 37

DC Power Cables
The cables dimensions are 26 mm2 for cable lengths up to 60 m and
210 mm2 for cable lengths up to 100 m.
Table 16

DC Power Cable Specifications

Application

Connector

Length (m)

Product Number(1)

RRU22

ODC to open end

0.5, 10, 25, 50,


80, 100

RPM 119 0261/L

RRUW-01
RRUN

Open end to open


end

100, 300

TFL 492 325/L


(210 mm cable drum)

RRUW-01
RRUN

Open end to open


end

100, 200, 500

TFL 492 324/L


(26 mm cable drum)

Adapter when replacing RRU22


with RRUW-01

Open end to ODC


(f)

1.5

RPM 919 662/01500

(1)

(2)

L = defined length of cable.

(2) 26 mm2 up to 60 m, 210 mm2 up to 100 m

AC Power Cables
Table 17

AC Power Cable Specifications

Application

Connector

Length (m)

Product Number(1)

PSU (indoor
RRU22/RRUW-01)

Open-end to
ODC

0.5, 5

RPM 119 0474/L

ACCU (outdoor
(RRU22/RRUW-01)

Open end to
open end

0.5, 10, 25, 50,


100

RPM 119 0552/L

PSU-AC (RRUN)
(1)

L = defined length of cable.

5.3 Jumper Cables

Figure 17
Table 18

Jumper Cable Connectors Without Protective Covers


Jumper Cable Specifications

Application

Connector

Length (m) Dimension

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

Product Number

6/21/2013

Main-Remote Installation Products Overview

Page 19 of 37

(1)

RRU22
RRUW-01
RRUN

(1)

7-16(m) to 7-16(m) 1, 2, 3, 5,
7.5, 10

1/2"

TSR 951 70/L

7-16(m) to 7-16(m) 1, 2, 3, 5

1/2"

TSR 951 331/L

N-type to 7-16(m)

1.5

1/4"

RPM 119 342/4

N-type to 7-16(m)

1/4"

RPM 119 0245/4

L = defined length of cable.

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 20 of 37

5.4 TG Synchronization Cables for GMS

Figure 18
Table 19

TG Synchronization Cable Connectors Without Protective Covers


Transceiver Group (TG) Synchronization Cable Specifications

Application

Connector

Length

Product Number(1)

MU-01, MU-03, MU-11 to


MU-01, MU-03, MU-11

ODC to ODC

5.5, 25

RPM 119 0408/L

MU-01, MU-03, MU-11 to


MU-12 or outdoor macro RBS

ODC to open end

4, 25

RPM 119 0413/L

MU-01, MU-03, MU-11 to


indoor macro RBS (not DXU-31)

ODC to
9-pin D-sub

4, 25

RPM 119 0417/L

MU-01, MU-03, MU-11 to


RBS 2216 V1 (DXU-31)

ODC to RJ45

6, 25

RPM 119 0418/L

MU-12 to
MU-12 or outdoor macro RBS

Open end to open


end

4, 5.5, 25

RPM 119 0584/L

MU-12 to
indoor macro RBS (not DXU-31)

Open end to 9-pin 4, 25


D-sub

RPM 119 0586/L

MU-12 to
RBS 2216 V1 (DXU-31)

Open end to RJ45

RPM 119 0587/L

(1)

6, 25

L = defined length of cable.

5.5 RET Control Cables

Figure 19
Table 20

RET Control Cables


RET Control Cable Specifications

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 21 of 37

Application

Connector

Length (m)

Product Number(1)

RRU22 (20W)

8-pole DIN to 4-pin


M12

1.5, 2.5, 3.5, 15

TSR 484 31/L (Black)

RRU22 (20W)

8-pole DIN to 4-pin


M12

1.5, 2.5, 3.5, 15

TSR 484 32/L (Gray)

RRUW-01

8-pole DIN to 8-pole 1, 2, 3, 15


DIN

1/TSR 484 21/L (Black)

RRUW-01

8-pole DIN to 8-pole 1, 2, 3, 15


DIN

1/TSR 484 22 (Gray)

(1)

L = defined length of cable.

5.6 Grounding Kit Cables


Table 21

Grounding Cable Kit Specifications

Application

Connector

Length (m)

Product number

Indoor cabinets

M8 cable lug

5/NTM 201 201/2

M8 cable lug

5/NTM 201 201/3

M8 cable lug

5/NTM 201 201/4

M8 cable lug

40

9/NTM 201 230/1

Outdoor cabinets

6 Installation Materials
6.1 Antenna Support Products

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 20

Page 22 of 37

Antenna Support

A: Freestanding Tripod 5.5 m


Table 22

Freestanding Tripod 5.5 m Specifications

Product number

NTM 201 3167/1

Description

Freestanding tripod antenna support; the construction is


preferably balanced with concrete blocks 50050050 mm
(not supplied).

Tube length

5500 mm

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Tube diameter

114 mm

Weight

135 kg, excluding concrete blocks

Max. wind load (at 55 m/s)

Max 1.5 m2

Page 23 of 37

B: Freestanding Antenna Support 2 m


Table 23

Freestanding Antenna Support 2 m Specifications

Product number

NTM 201 1205/1

Description

Freestanding antenna support; the construction is balanced


with supplied concrete blocks

Tube length

2000 mm

Tube diameter

60 mm

Weight

112 kg, incl. concrete blocks.

Max. wind load (at 55 m/s)

Max 0.6 m2

C: Freestanding Antenna Support 3 m


Table 24

Freestanding Antenna Support 3 m Specifications

Product number

NTM 201 3164/1

Description

Freestanding antenna support with adjustable shut support;


the construction is preferably balanced with concrete blocks
50050050 mm (not supplied).

Tube length

3000 mm

Tube diameter

76 mm

Weight

122 kg, excluding concrete blocks

Max. wind load (at 55 m/s)

Max 1.0 m2

D: Freestanding Antenna Support For Wall


Table 25

Freestanding Antenna Support For Wall Specifications

Product number

NTM 201 3163/1

Description

A freestanding rooftop antenna support for easy and fast


installation; the construction is balanced with supplied
concrete blocks.

Tube length

1200 mm

Weight

131 kg, incl. concrete blocks

Tube diameter

60 mm

Max. wind load (at 55 m/s)

Max 0.6 m2

E: 3-Sector Antenna Mount


Table 26

3-Sector Antenna Mount Specifications

Product number

SXK 107 2150/1

Description

The product is designed to install 3 sector antennas on one

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 24 of 37

single pole.
Weight

6.6 kg

Max. wind load (at 55 m/s)

Max 1.0 m2

F: Antenna Support for Tower Installation


Table 27

Antenna Support for Tower Installation Specifications

Product number

SXK 107 2126/1

Description

The product is to be used in pairs when fastening antenna


tubes on tower legs.
The tubes delivers in three lengths:
- SXA 120 729/16, 60 mm, 1.6 m
- SXA 120 215/29, 75 mm, 2,9 m
- SXA 120 216/40, 90 mm, 4 m

Weight

8 kg

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 25 of 37

G: Antenna Support Kit 3 m


Table 28

Antenna Support Kit Specifications

Product number

SXK 107 2022/1

Description

Basic antenna support kit for wall or roof; 3 m tube with


support.

Weight

43.6 kg

Max. wind load (at 55 m/s)

Max 1.0 m2

H: Antenna Support Kit for Wall


Table 29

Antenna Support Kit for Wall Specifications

Product number

SXK 107 2146/1


SXK 107 2146/2

Description

A light non penetrating rooftop antenna support kit. Comes in


two versions; one for walls with a thickness 100490 mm, and
one for walls with a thickness of 5001000 mm.

Tube length

1500 mm

Tube diameter

60 mm

Weight

14 kg / 15.5 kg

Max. wind load (at 55 m/s)

Max 0.6 m2

6.2 Cable Support and Accessories


Cable Tube

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 21
Table 30

Page 26 of 37

Cable Tubes
Cable Tube Specifications

Position in Figure A

Product number

NTM 201 3727/1

NTM 201 3811/1

Tube length

8.5 m (51.7 m)

25 m

Tube diameter

40/35 mm for all 3 sectors

50/40 mm for all 3 sectors

Weight

3.5 kg

19 kg

Installation
possibilities

Ladder, wall, tower

Ladder, wall, tower

Description

Straight split tubes, incl.


fastening material

Flexible cable tube kit, incl. pull wire and


fastening material

Cable Support Kit

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 22
Table 31

Page 27 of 37

Cable Support Kit


Cable Support Kit Specifications

Product number

NTM 201 3728/1

Description

Support kit for three fiber cables and three power cables

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 28 of 37

6.3 Tools and Instruments

Figure 23
Table 32

Tools and Instruments


Tool and Instrument Specifications

Position
in Figure

Product

Product
Number

Compatible
Connector Types

Description

Fiber Check Tool

LPK 112 102/1

LC, SC, ODC

Used to verify with visible


light if fiber is ok or not

Ferrule End-face
Cleaner

LTT 601 154/1

LC, SC

Used to clean fiber ends

OTDR

LPB 102 111/1

LC, SC

Optical Site Master with


power meter for
measurement of OIL cable
and optical transmission;
Testing distance up to
2.5 km.

6.4 Miscellaneous Products


Cable Winder Box

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 24
Table 33

Page 29 of 37

Three Cable Winder Boxes


Cable Winder Box Specifications

Product Number

NTM 201 3729/1

Description

Holds excess fiber cable (up to 30 m)

Dimensions

280440 mm

Weight

1.1 kg

Installation options

Wall, tower, 19-inch rack, stackable

Label Set for Cables


Table 34

Cable Label Set Specifications

Specification WCDMA

GSM

Product
Number

NTM 201 3767/1

NTM 201 3767/2

Description

Complete set of labels for fiber, power and RF cables

Max. sectors

Earth Grounding
Table 35

Earth Grounding Specifications

Product number

Description

9/NTM 201 230/2

Earth grounding rod for installation into the ground

NTM 201 3326/1

Earth grounding bar for towers and city sites

Fiber Connection Box


Table 36

Fiber Connection Box Specifications

Product
number

Description

NCD 901 37/1

Outdoor fiber connection box for distribution to three RRUs, incl. three LC duplex

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 30 of 37

adapters
Indoor Cable Chute

Figure 25
Table 37

Indoor Cable Chute


Indoor Cable Chute Specifications

Product number

NTM 201 3730/1

Dimensions (WH)

2540 mm

Chute length

22 m

Weight

1.1 kg

Installation possibilities

Ladder, wall

Description

To protect fiber cables

7 Type Sites
7.1 Type Site 1 - Outdoor Greenfield Site

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 26
Table 38

Page 31 of 37

Outdoor Greenfield Site


Outdoor Greenfield Site Specifications

Position Product Number


in
Figure

Description

NTM 201 3728/1

Cable
support kit

NTM 201 3727/1

Outdoor
cable tube
kit

NTM 201 3729/1

Overlength
box kit

SXK 107 2126/1

Antenna
Support Kit

SXA 120 729/16

Tube, 1.6 m

7.2 Type Site 2 - Greenfield Shelter Site

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 27
Table 39

Page 32 of 37

Greenfield Shelter Site


Greenfield Shelter Site Specifications

Position in Figure

Product Number

Description

NTM 201 3448/2

Cable sealing

NTM 201 3730/1

Indoor cable chute

NTM 201 3604/2

19-inch rack frame, 48 U

NTM 201 3729/1

Overlength box kit

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 33 of 37

7.3 Type Site 3 - Rooftop Indoor Site

Figure 28
Table 40

Rooftop Indoor Site


Rooftop Indoor Site Specifications

Position in Figure

Product Number

Description

NTM 201 3605/1

19-inch rack frame, 16U

NTM 201 3729/1

Overlength box kit

NTM 201 3811/1

Tube kit

SXK 107 21 46/1

Antenna support for wall

NTM 201 3164/1

Freestanding antenna support

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Page 34 of 37

7.4 Type Site 4 - Rooftop Outdoor Site

Figure 29
Table 41

Rooftop Outdoor Site


Rooftop Outdoor Site Specifications

Position in Figure

Product Number

Description

NTM 201 3167/1

Antenna support, freestanding

SXK 107 2150/1

3 sector antenna installation kit

7.5 Type Site 5 - Rooftop Shelter Site

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 30
Table 42

Page 35 of 37

Rooftop Shelter Site


Rooftop Shelter Site Specifications

Position in Figure

Product Number

Description

NTM 201 3604/2

19-inch rack frame, 48 U

SXK 107 2126/1

Tower installation support

SXA 120 729/16

Tube, 1.6 m

7.6 Type Site 6 - Rooftop Outdoor Site

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

Figure 31
Table 43

Page 36 of 37

Rooftop Outdoor Site


Rooftop Outdoor Site Specifications

Position in Figure

Product Number

Description

NTM 201 1205/1

Antenna support

NTM 201 3811/1

Tube kit

8 Terms and Abbreviations


ACCU

Alternating Current Connection Unit

BU

Battery Unit

MPH

Modem Protective Housing

MU

Main Unit

ODC

Outdoor Connector

OIL

Optical Interface Link

PBC-02

Power and Battery Cabinet-02

PSU

Power Supply Unit

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

6/21/2013

Main-Remote Installation Products Overview

RETU

Remote Electrical Tilt Unit

RRU

Remote Radio Units

RRUN

RRU for GSM

RRUW

Remote Radio Unit Wideband

SSC

Site Support Cabinet

TG

Transceiver Group

TMR

Transmission Rack

TRX

Transceivers

file://C:\Users\Dell\AppData\Local\Temp\ALEX_TMP\1027\alex0372.htm

Page 37 of 37

6/21/2013